Sei sulla pagina 1di 3

KIS-8

Nobel Weighing Systems

Weigh Module
FEATURES
Capacity range - 1, 2, 5, 10, 20, 50, 100, and 200kN (225,
450, 1.12K, 2.25K, 4.5K, 11.2K, 22.4K, and 44.9K lb)
Simple installation
Moveable load point
Withstands very high lateral forces
Extremely accurate and rugged
ATEX certified for hazardous locations

APPLICATIONS
Silo/bin/hopper inventory weighing systems
Mixing and blending tanks

DESCRIPTION

Force measurement systems

The KIS-8 load cell has several features that distinguish it


from other load cells. It is easy to install and extremely
accurate, even when subjected to disruptive industrial
forces and harsh environmental conditions. All KIS load cells
can be ATEX certified for use in explosive atmospheres.

Conveyors

OUTLINE DIMENSIONS
Recommended Loading Point

B2
B4

K (2x)

H4

Indicates direction
of measurement

H1
H3

VISHAY NOBEL
S-69127KARLSKOGA Sweden

H5

TYPE
R.L.
R.O.

H6

40K
80KR.OUT
S.N

H2

H7

Option:
Tilt guard

50
G

J
A6

L (4x)
M (4x)

B1
B3
D

F
B5

A4
A7

A5

C
A2
A1

A3

RANGE kN
1-2
5-10-20
50
100
200

A1
175
204
280
310
340

A2
151
180
245
270
300

A3
12
12
17.5
20
20

A4
31
32
46.5
63
71

A5
31
50
65
65
65

A6
20
20
30
39
49

A7
-6
21
21
22
37

B1
75
100
150
170
180

B2
70
100
150
160
190

B3
51
76
115
130
140

RANGE kN
1-2
5-10-20
50
100
200

H1
81
107.5
152
173
199

H2
14
18
28
28
36

H3
67
89.5
124
145
163

H4
41
54
72
85
95

H5
48
68
94
108
118

H6
27.5
38.5
54.5
65
72

H7
14
18
28
38
48

I
22
26.5
36
57
80

J
30
77
98
96
96

K
8.5
11
18
22
25

B4
55
75
115
126
146

B5
48
73
97
118
132

L
M6 x 60
M10 x 80
M12 x 110
M16 x 140
M20 x 150

C
14
12
14
15
16
M
11
12
15
22
25

D
33
50
75
90
100

E
54
56
72
78
92

P
Circlip (2x)
16
32 x 1.5
11.5
50 x 2
17
75 x 2.5
17
90 x 3
17
100 x 3

F
39
53
72
88
96
R
M8
M10
M16
M20
M24

G
78
79
97
108
128
S
19
27
43
50
57

Document Number: 12311 Technical contact in Americas: pw.usa@vishaypg.com, Europe: pw.eur@vishaypg.com, www.weighingsolutions.com
Revision: 18-Mar-10
China: pw.prc@vishaypg.com, Taiwan: pw.roc@vishaypg.com
1

KIS-8
Nobel Weighing Systems

Weigh Module

SPECIFICATIONS
PARAMETER
Rated load (R.L.)
Combined error (terminal)
Repeatability
Overload
Sideload
Input voltage
Input resistance
Output resistance
Rated output (R.O.)
Tolerance of R.O.
Zero balance
Tolerance of shunt calibration values
Creep at R.L. after 30 minutes
Temperature range
Temperature effect (- 10C to + 50C)
Insulation resistance at 200 V DC
Material
Electrical connection
Degree of protection

VALUE

safe
ultimate
ultimate
recommended
maximum

on output
on zero balance

UNIT

1, 2, 5, 10, 20, 50, 100, 200


kN
0.075
% of R.O.
0.02
% of R.O.
50 (1)
% of R.L.
100 (1)
% of R.L.
100 (1)
% of R.L.
10
V DC or AC
18
V DC or AC
350 5
ohm
350 0.5
ohm
2.040
mV/V
0.25
% of R.O.
2
% of R.O.
0.25
% of value (2)
0.03
% of R.L.
- 40 to + 80 (+ 100) (3)
C
0.003
% of output/C
0.003
% of R.O./C
>4
Gohm
Stainless steel
5 m shielded four conductor cable
1, 2, 5, 10, 20 kN
10 m shielded four conductor cable
50, 100, 200 kN
IP 67
ATEX certified versions for use in explosive atmosphere are available
II 1GD

Notes
(1) Referring to recommended loading case
(2) See calibration sheet of the load cell
(3) - 40 to + 100C on demand

INSTALLATION EXAMPLES

www.weighingsolutions.com Technical contact in Americas: pw.usa@vishaypg.com, Europe: pw.eur@vishaypg.com, Document Number: 12311
2
China: pw.prc@vishaypg.com, Taiwan: pw.roc@vishaypg.com
Revision: 18-Mar-10

Legal Disclaimer Notice


Vishay Precision Group, Inc.

Disclaimer
ALL PRODUCTS, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Vishay Precision Group, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf
(collectively, VPG), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in
any other disclosure relating to any product.
The product specifications do not expand or otherwise modify VPGs terms and conditions of purchase, including but
not limited to, the warranty expressed therein.
VPG makes no warranty, representation or guarantee other than as set forth in the terms and conditions of purchase.
To the maximum extent permitted by applicable law, VPG disclaims (i) any and all liability arising out of the
application or use of any product, (ii) any and all liability, including without limitation special, consequential or
incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose,
non-infringement and merchantability.
Information provided in datasheets and/or specifications may vary from actual results in different applications and
performance may vary over time. Statements regarding the suitability of products for certain types of applications
are based on VPGs knowledge of typical requirements that are often placed on VPG products. It is the customers
responsibility to validate that a particular product with the properties described in the product specification is suitable for
use in a particular application. You should ensure you have the current version of the relevant information by contacting
VPG prior to performing installation or use of the product, such as on our website at vpgsensors.com.
No license, express, implied, or otherwise, to any intellectual property rights is granted by this document, or by any
conduct of VPG.
The products shown herein are not designed for use in life-saving or life-sustaining applications unless otherwise
expressly indicated. Customers using or selling VPG products not expressly indicated for use in such applications do
so entirely at their own risk and agree to fully indemnify VPG for any damages arising or resulting from such use or sale.
Please contact authorized VPG personnel to obtain written terms and conditions regarding products designed for such
applications.
Product names and markings noted herein may be trademarks of their respective owners.
Copyright Vishay Precision Group, Inc., 2014. All rights reserved.

Document No.: 63999


Revision: 15-Jul-2014

www.vpgsensors.com
1

Potrebbero piacerti anche