HVSI 80
Self-regulating brushless generators
There for youTM
Features
STANDARD FEATURES :
z Cast and welded construction optimising strength and
output to weight ratio.
z Modular construction chosen to minimise manufacturing
lead times.
z Winding designs available to give a wide range of voltages,
380-480 V, 690 V, 2400 V, 3300 V, 4160 V, 6600 V, 7200 V,
10 kV, 11 kV, 12.47 kV, 13.8 kV. Other voltages available by
request
z High quality Silicon electrical steel used for rotor and stator
construction.
z Rotors are constructed with fully interconnected damper
(amortisseur) windings.
z Controls and system monitoring devices are housed in a
separate machine mounted enclosure.
z AvK/ STAMFORD DM110 Digital AVR (by Basler)
z Power factor controller as standard.
z Manual voltage regulation as standard.
Standards
P80 Industrial Generators meet the requirements
of BSEN60034 and the relevant sections of other
international standards such as BS5000, VDE
0530, Nema MG1-32, IECEN60034, CSA C22.2100 and AS1359.
Marine generators may be certified to Lloyds, DNV,
Bureau Veritas, ABS, Germanischer-Lloyd or RINA.
Other standards and certifications can be
considered on request.
Quality Assurance
Generators are designed and manufactured to QA
Procedures conforming to ISO9001.
ELECTRICAL FEATURES :
AVR
The P80 range of generators are fitted with the AvK,
STAMFORD DM110 digital excitation system. This is an
electronic, solid-state, microprocessor based device developed
in conjunction with Basler and supplied exclusively for AvK
STAMFORD generators. The input power to the excitation
system is supplied by a multi-pole, high frequency, permanent
magnet generator (PMG). The DM110, with PMG, is fitted as
standard to the P80 range of generators. The PMG provides
power via the DM110 AVR to the main exciter, giving a source
of constant excitation power independent of generator output.
The exciter output is then fed to the main rotor, through a full
wave bridge rectifier, protected by surge suppressors.
The AVR has in-built protection against generator overvoltage,
loss of sensing voltage and field overvoltage (Overexcitation
shutdown). Overexcitation and underexcitation limiters are also
a feature of this AVR.
An engine relief load acceptance feature can enable full
load,in accordance with ISO8528, to be applied to the
generator in a single step.
Voltage Regulation
The 3 phase or single phase RMS voltage sensing in AVR
mode. Regulation of 0.5%, from no load to full load including
cold to hot variations for any power factor between 0.8 lagging
and unity, allowing for 4 % engine speed variations. It is
particularly suitable for non-linear load applications.
True RMS sensing
The PMG together with true r.m.s. sensing provides isolation
from distorted voltage waveforms associated with non linear
loads. No additional harmonic filtration is required.
Three phase sensing
Three phase sensing centres any voltage imbalance, caused
by load imbalance, on the nominal voltage, and helps to
ensure trouble free operation under the most demanding
loads.
Short circuit
Industrial machine will sustain a maximum short circuit of
300% rated current under a 3 phase L-L-L short circuit
condition. The AVR will support this condition for up to 10
seconds, at which point the AVR over-excitation protection
system will de-excite the machine. Sustained current levels
under 2 phase L-L or 1 phase L-Nshort circuit levels are much
higher than the above L-L-L levels and must be removed from
the generator, by breakers, within typically 5 seconds and 2
seconds respectively.
PMG
Stamford's most advanced Permanent Generator (PMG)
excitation system, for the ultimate in reliability, response and
stability, is fitted as standard. The DM110 digital automatic
voltage regulator (AVR), designed and produced specifically for
the P80 range of ac generators, is also fitted as standard.
Parallel Operation
All P80 generators are well suited for parallel operation with
the mains utility or other generators. For paralleling with the
utilities power factor correction or reactive power (var)
regulation are features of the DM110 AVR.
Our standard winding pitch is 2/3. However consideration
needs to be given to other conditions such as, pitch of sets
already on site and how neutrals are connected. An Excitation
Loss Module (ELM) will give protection against loss of
excitation from the excitation system. The ELM is housed in
the generator's separate low voltage control box, and may be
supplied either factory fitted or for after-market fitment.
Insulation/Impregnation
The impregnation materials and processes are specifically
selected to provide protection against harsh environments
encountered by generator applications. Resins are selected
and developed to provide the
high build required for static windings and the high mechanical
strength required for rotating components.
For High Voltage stators, (> 4400 V) Stamford has a Hybrid
System using the best features of Global VPI and Resin rich
Technology, to give a superior product, optimising insulation life
in the stator slot section,with the advantage of VPI epoxy in the
out-hangs for strength, electrical properties and optimum
protection. This insulation system has been selected to give
PROVEN results, with maximum benefit to the customer in
terms of DURABILITY and RELIABILITY. All HV machines
have Corona Protection tapes applied.
For Medium voltage machines (Up to 4400 V) Stamford has
developed a Class H insulation system, using mica and
Nomex technology for optimal results and performance.
All P80 stators and rotors are rotate cured to retain resin in the
slot section, to give a uniform resin coating overall for
protection, for uniform balance of rotating components and
most importantly on HV stators, to prevent the formation of
resin spikes, which can act as electrical stress points in the
winding.
Class F insulation system and Class F rating on HVSI
Class H insulation system and Class H rating on LVSI, LVSM
and MVSI.
MECHANICAL FEATURES :
Terminal Box
Instrument and control connections are in a separated
compartment, with external access for safety. The wiring
diagram for the machine is fitted within this compartment.
Heater connections, which remain live after generator
shutdown, are designed to prevent direct contact, for reasons
of safety. Terminal boxes are designed to be rugged and
internal components are designed for durability and reliability at
the high levels of imposed vibration from the prime mover. The
terminal box is designed with the provision for propriety CT's to
be field retrofitted, relatively easily, by skilled personnel.
Vibration Limits
All generator rotors are dynamically balanced to better than
BS6861: Part 1, Grade 2.5 for minimal vibration during
operation. Two bearing generators are balanced with a half
key.
Bearings
Stamford P80 generators use deep groove ball bearing
technology to satisfy the needs of industrial and marine
Features
OPTIONS / ACCESSORIES :
z SAE 0 or 00 Flange adapters for 2 bearing machines
z SAE 0 or 00 adapter for 1 bearing machines
z 18, 21 and 24 drive discs available for single bearing
machines with matching SAE adapter
z Bearing RTD's (PT100, 3 wire)
z Insulated bearings (Subje ct to conditions)
z Winding RTD's (PT100, 3 wire) - Standard on MV
& HV
z Anti-condensation heaters (Standard on MV/HV).
Recommended option on LV
Construction
Modular in concept. The stator core is manufactured from
electrical steel laminations pressed between two thick end
plates. The core is welded to landing bars to form the main
structure of the generator. Cast SG Iron bearing end shields,
for strength and rigidity, are designed with bolt on feet to
provide alternative foot heights to suit the base frame. The
complete machine is modelled in 3D, for Finite Element
Analysis (FEA)
on components/assembly for fatigue, maximum stresses and
natural frequencies. The 3D model is available to customers for
set and bed frame design assistance.
Gas and Steam Turbines
Many of these applications require a hard mounting capability,
without resilient mounts. The two bearing rolling element
bearing design for R, S & T cores are suitable for hard
mounting, with factory specified bed minimum stiffness criteria.
For other applications, consult factory.
Direction of Rotation
P80 generators are configured for clockwise rotation (as seen
from the Drive End) as standard. Anticlockwise rotation is
available as an option.
Nominal Ratings
Power Factor
0,8
Connecting
3 Phase (6 Wire)
50 Hz (1500 RPM)
Class F
Rating/Ambient
Class B
Basic / 40C
Application/Temp. Rise
Voltage: Star
Continuous/105K
6000V
Winding No.
Peak / 40C
6300V
Basic / 40C
Standby/125K
6600V
6000V
6300V
Continuous/80K
6600V
6000V
6300V
6600V
71
61
61
71
61
61
71
61
61
2250
2148
2250
2400
2291
2400
1950
1861
1950
HVSI 804R
kVA
kW
1800
1718
1800
1920
1833
1920
1560
1489
1560
HVSI 804S
kVA
2520
2405
2520
2695
2573
2695
2200
2100
2200
kW
2016
1924
2016
2156
2058
2156
1760
1680
1760
HVSI 804T
kVA
2875
2744
2875
3075
2935
3075
2480
2368
2500
kW
HVSI 804W kVA
HVSI 804X
2300
2195
2300
2460
2348
2460
1984
1894
2000
3410
3255
3410
3640
3475
3640
2970
2835
2970
kW
2728
2604
2728
2912
2780
2912
2376
2268
2376
kVA
3875
3699
3875
4140
3952
4140
3370
3226
3380
kW
3100
2959
3100
3312
3162
3312
2696
2581
2704
Power Factor
0,8
Connecting
3 Phase (6 Wire)
50 Hz (1500 RPM)
Class F
Rating/Ambient
Application/Temp. Rise
Voltage: Star
HVSI 804S
HVSI 804T
Peak / 40C
Basic / 40C
Standby/125K
Continuous/80K
10500V
11000V
10000V
10500V
11000V
10000V
10500V
11000V
81
83
83
81
83
83
81
83
83
kVA
2270
2168
2270
2430
2320
2430
2000
1909
2000
kW
1816
1734
1816
1944
1856
1944
1600
1527
1600
kVA
2515
2401
2515
2690
2568
2690
2200
2100
2200
kW
2012
1921
2012
2152
2054
2152
1760
1680
1760
kVA
2840
2711
2840
3035
2897
3035
2500
2386
2500
kW
2272
2169
2272
2428
2318
2428
2000
1909
2000
Basic / 40C
Continuous/105K
10000V
Winding No.
HVSI 804R
Class B
3259
3111
3259
3470
3312
3470
2830
2701
2830
kW
2607
2489
2607
2776
2650
2776
2264
2161
2264
kVA
3724
3555
3724
3960
3780
3960
3240
3093
3240
kW
2980
2844
2980
3168
3024
3168
2592
2474
2592
Nominal Ratings
Power Factor
0,8
Connecting
3 Phase (6 Wire)
60 Hz (1800 RPM)
Class F
Class B
Rating/Ambient
Basic / 40C
Peak / 40C
Basic / 40C
Application/Temp. Rise
Continuous/105K
Standby/125K
Continuous/80K
Voltage: Star
7200V
11400V
12470V
7200V
11400V
12470V
7200V
11400V
12470V
71
81
87
71
81
87
71
81
87
kVA
2875
2588
2650
3075
2770
2840
2510
2280
2312
kW
2300
2070
2120
2460
2216
2272
2008
1824
1850
Winding No.
HVSI 804R
HVSI 804S
HVSI 804T
kVA
3140
2868
2900
3360
3065
3090
2750
2505
2535
kW
2512
2294
2320
2688
2452
2472
2200
2004
2028
kVA
3530
3238
n/a
3775
3460
n/a
3080
2850
n/a
kW
2824
2590
n/a
3020
2768
n/a
2464
2280
n/a
4200
3715
n/a
4490
3950
n/a
3660
3226
n/a
3360
2970
n/a
3592
3160
n/a
2928
2581
n/a
kVA
4750
4245
n/a
5080
4510
n/a
4130
3694
n/a
kW
3800
3396
n/a
4064
3608
n/a
3304
2955
n/a
Power Factor
0,8
Connecting
3 Phase (6 Wire)
60 Hz (1800 RPM)
Class F
Class B
Rating/Ambient
Basic / 40C
Peak / 40C
Basic / 40C
Application/Temp. Rise
Continuous/105K
Standby/125K
Continuous/80K
Voltage: Star
12470V
13200V
13800V
12470V
13200V
13800V
12470V
13200V
13800V
91
91
91
91
91
91
91
91
91
kVA
2400
2535
2650
2570
2720
2840
2080
2200
2312
kW
1920
2030
2120
2056
2176
2272
1664
1760
1850
kVA
2710
2870
3000
2900
3070
3200
2355
2490
2625
kW
2168
2296
2400
2320
2456
2560
1884
1992
2100
kVA
2980
3155
3300
3185
3375
3530
2590
2740
2880
kW
2384
2524
2640
2548
2700
2824
2072
2192
2304
Winding No.
HVSI 804R
HVSI 804S
HVSI 804T
3365
3560
3724
3580
3790
3960
2930
3100
3240
kW
2692
2848
2979
2864
3032
3168
2344
2488
2592
kVA
3810
4030
4214
4050
4295
4490
3300
3500
3660
kW
3048
3224
3371
3240
3436
3592
2640
2800
2928
Nominal Ratings
Power Factor
0,8
Connecting
3 Phase (6 Wire)
50 Hz (1500 RPM)
Class H
Class F
Class H
Class B
Rating/Ambient
Basic / 40C
Basic / 40C
Peak / 40C
Basic / 40C
Application/Temp. Rise
Continuous/125K
Continuous/105K
Standby/150K
Continuous/80K
Voltage: Star
3300-3450V
3300-3450V
3300-3450V
3300-3450V
51
51
51
51
kVA
2650
2400
2835
2100
kW
2120
1920
2268
1680
kVA
2900
2660
3100
2330
kW
2320
2128
2480
1864
Winding No.
MVSI 804R
MVSI 804S
MVSI 804T
MVSI 804W
MVSI 804X
kVA
3300
3020
3530
2650
kW
2640
2416
2824
2120
kVA
3718
3475
3960
3114
kW
2974
2780
3168
2491
kVA
4253
3975
4520
3562
kW
3402
3180
3616
2850
Power Factor
0,8
Connecting
3 Phase (6 Wire)
60 Hz (1800 RPM)
Class H
Class F
Class H
Class B
Rating/Ambient
Basic / 40C
Basic / 40C
Peak / 40C
Basic / 40C
Application/Temp. Rise
Continuous/125K
Continuous 105K
Standby/150K
Continuous/80K
Voltage: Star
4000-4160V
4000-4160V
4000-4160V
4000-4160V
51
51
51
51
kVA
3150
2880
3370
2520
kW
2520
2304
2696
2016
kVA
3530
3250
3775
2820
kW
2824
2600
3020
2256
Winding No.
MVSI 804R
MVSI 804S
MVSI 804T
MVSI 804W
MVSI 804X
kVA
4060
3725
4340
3250
kW
3248
2980
3472
2600
kVA
4494
4200
4780
3650
kW
3595
3360
3824
2920
kVA
5190
4850
5520
4215
kW
4152
3880
4416
3372
Nominal Ratings
Power Factor
0,8
Connecting
Rating/Ambient
Application/Temp. Rise
Voltage : Star
LVSI 804R
LVSI 804S
LVSI 804T
LVSI 804W
LVSI 804X
LVSI 804Y
kVA
Class H
Peak / 40C
Continuous/125K
380V
Winding No.
Class H
Basic / 40C
400V
415V
Standby/150K
440V
660-690V
380V
400V
415V
440V
660-990V
12
12
12
12
65
12
12
12
12
65
2290
2410
2410
2265
2410
2445
2575
2575
2420
2575
kW
1832
1928
1928
1812
1928
1956
2060
2060
1936
2060
kVA
2650
2790
2790
2620
2790
2835
2985
2985
2805
2985
kW
2120
2232
2232
2096
2232
2268
2388
2388
2244
2388
kVA
2895
3050
3050
2865
3050
3095
3260
3260
3065
3260
kW
2316
2440
2440
2292
2440
2476
2608
2608
2452
2608
kVA
3375
3555
3555
3340
3555
3610
3800
3800
3570
3800
kW
2700
2844
2844
2672
2844
2888
3040
3040
2856
3040
kVA
3715
3911
3911
3675
n/a
3970
4180
4180
3970
n/a
kW
2972
3129
3129
2940
n/a
3176
3344
3344
3176
n/a
kVA
n/a
n/a
n/a
n/a
3800
n/a
n/a
n/a
n/a
4065
kW
n/a
n/a
n/a
n/a
3040
n/a
n/a
n/a
n/a
3252
Power Factor
0,8
Connecting
Rating/Ambient
Class B
Basic / 40C
Application/Temp. Rise
Basic / 40C
Continuous/105K
Continuous/80K
Voltage : Star
380V
400V
415V
440V
660-690V
380V
400V
415V
440V
660-990V
Winding No.
12
12
12
12
65
12
12
12
12
65
kVA
2100
2210
2210
2075
2210
1830
1930
1930
1815
1930
kW
1680
1768
1768
1660
1768
1464
1544
1544
1452
1544
kVA
2430
2560
2560
2405
2560
2125
2240
2240
2105
2240
kW
1944
2048
2048
1924
2048
1700
1792
1792
1684
1792
LVSI 804R
LVSI 804S
LVSI 804T
LVSI 804W
LVSI 804X
LVSI 804Y
kVA
2660
2800
2800
2630
2800
2325
2450
2450
2300
2450
kW
2128
2240
2240
2104
2240
1860
1960
1960
1840
1960
kVA
3155
3322
3322
3122
3322
2740
2887
2887
2715
2887
kW
2524
2658
2658
2498
2658
2192
2310
2310
2172
2310
kVA
3470
3655
3655
3435
n/a
3015
3177
3177
2980
n/a
kW
2776
2924
2924
2748
n/a
2412
2542
2542
2384
n/a
kVA
n/a
n/a
n/a
n/a
3535
n/a
n/a
n/a
n/a
3080
kW
n/a
n/a
n/a
n/a
2828
n/a
n/a
n/a
n/a
2464
Nominal Ratings
Power Factor
0,8
Connecting
Rating/Ambient
Application/Temp. Rise
Voltage: Star
LVSI 804R
LVSI 804S
LVSI 804T
LVSI 804W
LVSI 804X
kVA
Class H
Peak / 40C
Continuous/125K
380V
Winding No.
Class H
Basic / 40C
416V
440V
460V
Standby/150K
480V
600V
380V
416V
440V
460V
480V
600V
13
12
12
12
12
07
13
12
12
12
12
07
2825
2600
2750
2875
3000
3000
3015
2780
2940
3066
3200
3200
kW
2260
2080
2200
2300
2400
2400
2412
2224
2352
2453
2560
2560
kVA
3250
2900
3070
3210
3350
3350
3470
3105
3285
3436
3585
3585
kW
2600
2320
2456
2568
2680
2680
2776
2484
2628
2749
2868
2868
kVA
3400
3170
3355
3508
3660
3660
3630
3390
3590
3753
3915
3915
kW
2720
2536
2684
2806
2928
2928
2904
2712
2872
3002
3132
3132
kVA
3750
3590
3800
3969
4142
4142
4000
3841
4060
4245
4430
4430
kW
3000
2872
3040
3175
3314
3314
3200
3072
3248
3396
3544
3544
kVA
n/a
3870
4090
4278
4464
4464
n/a
4130
4370
4571
4770
4770
kW
n/a
3096
3272
3422
3571
3571
n/a
3304
3496
3657
3816
3816
Power Factor
0,8
Connecting
Rating/Ambient
Basic / 40C
Application/Temp. Rise
Voltage: Star
LVSI 804S
LVSI 804T
LVSI 804W
LVSI 804X
Basic / 40C
Continuous/105K
Continuous/80K
380V
416V
440V
460V
480V
600V
380V
416V
440V
460V
480V
600V
13
12
12
12
12
07
13
12
12
12
12
07
kVA 2590
2385
2520
2635
2750
2750
2260
2080
2200
2300
2400
2400
kW
2072
1908
2016
2108
2200
2200
1808
1664
1760
1840
1920
1920
kVA 2975
2665
2820
2948
3075
3075
2630
2325
2455
2569
2680
2680
kW
2380
2132
2256
2358
2460
2460
2104
1860
1964
2055
2144
2144
kVA 3130
2910
3080
3220
3360
3360
2750
2600
2750
2875
3000
3000
kW
2504
2328
2464
2576
2688
2688
2200
2080
2200
2300
2400
2400
Winding No.
LVSI 804R
Class B
kVA 3450
3350
3550
3710
3871
3871
3030
2915
3085
3224
3364
3364
kW
2760
2680
2840
2968
3097
3097
2424
2332
2468
2579
2691
2691
kVA
n/a
3615
3820
3998
4172
4172
n/a
3140
3300
3474
3625
3625
kW
n/a
2892
3056
3198
3338
3338
n/a
2512
2624
2779
2900
2900
Design
Design
W,X & Y Two Bearing