SINGER Control Valves

• Pump control
• Pressure Management
• Flow control
• Relief-Sustaining-Surge Control
• Water Loss Management
• Level control
• SCADA Electronic Control
• High Performance Solutions

We offer a wide range of of automatic control valves to meet MATERIALS:


the needs of the Industrial, HVAC, Fire Protection, Irrigation and Body / Cover: Ductile Iron, Bronze, Cast Steel, AISI 316,
Water Works markets. Seat Ring: AISI 316
Diaphragm: EPDM, Buna, Viton (limited sizes)
Most SINGER Valves consist of main valve and a pilot control Stem: AISI 316
system designed specifically to meet the requirements of the Spring: AISI 302
application.

MAIN VALVES 106 series - FULL PORT 206 series - REDUCED PORT
We offer two distinct main body model series:
- 106 series - Full Port,
- 206 series - Reduced Port.
The model 206 series valves are similar to the model 106
series except that the series are typically one standard pipe size
smaller than the flange sizes (consult with us on larger sizes). FLANGE BORE
For example, a 6’’ (150mm) 206-PG valve has a 4’’ (100mm) seat 6” (150mm)

diameter. The model 206 is often a preferred selection when the


flow ranges are suitable.
SEAT BORE SEAT BORE
Smaller sized valves (106 up to 8’’ / 200mm and 206 up to 10’’ 6” (150mm) 4” (100mm)

/ 250mm) are Flat Diaphragm design. All larger sized valves are
Rolling Diaphragm design.
Rolling Diaphragm (below) Angle Pattern
Most sizes of valves are also available in Angle Pattern. vs. Flat Diaphragm (above) (106 series full port angle pattern
(106 series 10’’ PG model shown below) shown below)
PILOTS & CONTROLS
We offer a wide range of Pilot system options to suit the most
complex applications. We specialize in the following areas: water
loss management, pressure reducing control, relief, sustaining
and surge control, pump, level or flow control and electronic
control.

OPERATION
SINGER Control Valves are hydraulically operated by introducting
or releasing water from the control chamber above the diaphragm.
The main valve is combined with specific purpose pilots and
accessories to provide control for a wide range of functions.

We can customize to any required solution - please contact us to This brochure outlines only some of the many application
discuss your unique application requirements. solutions available. For further information please contact
us.

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963
ValvesSensorsSystems measurIT technologies

Standard Function Models

A1 - Two-Way Flow Altitude Control


Closes with precise repeatability on high reservoir level. Opens when supply pressure falls a
small fixed amount below the reservoir level.

A2 - One Way Flow Altitude Control


Closes with precise repeatability on high reservoir level. Opens when reservoir level falls a
LEVEL small fixed amount.
CONTROL F4 - Modulating Float
Pilot opens main valve and modulates, to balance inflow with outflow demand and maintains
level within close limits.

F5 - Non-Modulating Float
Pilot opens main valve fully to fill tank when level falls a preset (adjustable amount). Closes
tightly on high water level.

BPC - Booster Pump Control


Mounted in-line, the double chamber is designed to open fully and minimize losses. Prevents
surges associated with the starting and stopping of pumps.

PG-BPC - Booster Pump Control


Mounted in-line, the single chamber is designed to prevent surges associated with the
PUMP starting and stopping of pumps (often combined with pressure reducing, pressure sustaining
CONTROL and rate flow functions).

DW - Deep Well Pump Control - Double Chamber


Mounted in tee off main line. Discharges air and silt to waste and prevents starting and
stopping surges.

DWX - Deep Well Pump Control - Single Chamber


Similar to DW but single chamber with spring lift.
.

PR - Pressure Reducing
Automatically reduces higher upstream pressure to a lower downstream pressure (adjustable)
regardless of fluctuations in inlet pressure or flow. (If downstream pressure is 30% or less of
upstream please contact us).

PR-C - Pressure Reducing and Check


Similar to PR with added check function which closes the valve to prevent reverse flow on
PRESSURE pressure reversal.
CONTROL
PR-48 - Pressure Reducing
Reducing valve with low flow direct acting valve mounted on side of main valve to provide
stable flow down to zero.

PR-R - Pressure Reducing and Sustaining Valve


Combines PR and pressure sustaining functions. Sustaining feature permits the valve to
open only when the upstream pressure exceeds the sustaining pilot set point.
.

RF - Rate of Flow
Limits the flow to preset (adjustable) maximum. Paddle style orifice generates low signal.
FLOW HC - Hydraulic Check
CONTROL Permits one-way flow only and offers adjustable opening and closing speeds. When pressure
is reversed there is brief reverse flow and the valve closes tightly. (Usually installed with
forward flow over the seat for smoother closing).

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963
ValvesSensorsSystems measurIT technologies

Standard Function Models

RPS - Pressure Relief


Mounted in a tee off the main pipeline. Opens when inlet pressure exceeds a predetermined
setting. Relieves excess pressure to waste to limit the system maximum pressure.

RPS - Pressure Sustaining


Installed directly in main line. Opens when the inlet pressure exceeds a predetermined setting.
Closes on lower pressure to ensure upstream pressure does not fall below set point.

RPS-L&H - Anticipating Surge Relief


Automatically opens to dissipate the excess energy of a surge. Remains closed, drip tight,
when the system pressure is within the normal opening range. Opens quickly to relieve high
pressures or opens on under pressure to anticipate the return of a surge wave.
RELIEF,
SUSTAINING, RPS-RR
Mounted in a tee off the main pipeline. In addition to the standard relief function this valve
SURGE
responds to an abnormal rate of rise of pressure and opens repidly to dissipate a surge.
CONTROL
RPS-D - Pressure Differential Sustaining
Modulates to maintain a minimum pressure differential between sensing points upstream and
downstream of the valve. In line, maintains the head on a pump or in parallel limits pressure
differential across a device, such as in the case of air conditioning chillers.

RPS-SC - Pressure Sustaining / Relief with Solenoid Override


Combines RPS function with a solenoid override to open the main valve when the solenoid is
energized (De-Energized Optional).

DL - Dynamic Lifter® - Sewage Pressure Relief Valve


A direct acting spring loaded relief valve. Opens when the inlet pressure exceeds the set point.
Patented opening and servicing features.
.

SC - Solenoid Control
Solenoid control valves respond to an electrical signal to provide two-position (on/off) operation.
The SC valve is available either with the main valve closed when the solenoid is de-energized
(NC-Normally Closed) or with the main valve open when the solenoid is de-energized (NO-
Normally Open).

2SC-PCO - Dual Solenoid Control


Interfaces with controllers to provide electronic control of flow, pressure or level. Designed to
be acurately positioned anywhere within the full stroke of the valve. Able to mimic virtually any
of our hydraulic functions. Suitable for remote control.

ELECTRIC 2SC-MV
CONTROL Combines the electronic control of flow, pressure or level of a 2SC-PCO model with metering.
Uses advanced PLC controllers with both control and metering algorithms. Capable of local
display and re-transmission to remote stations.

Electronic Control Panels


SINGER designs and manufacturers a complete series of PLC and circuit-boar based electronic
control panels. The OMNI printed circuit board provides simple reliable P.I.D. control for the
standard 2SC-PCO valves. More advanced panel designs incorporate industrial PLC’s to
provide Pump Control, Surge Control or Metering functions. SINGER customizes the programs
to match your specific application needs.
Digital to analog and Human/Machine Interface (HMI) option available.
Complete panels wired and tested in-house.
.

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963
ValvesSensorsSystems measurIT technologies

High Performance Models

PR-AC - Pressure Reducing


Reduces high pipeline pressure
to constant standard lower
distribution pressure.

AC - Anti-Cavitation Control Valve


Controls varying flow througout full range
without damage, despite operating deep
within the cavitation zone. Excellent noise
RPS-AC - Pressure Relief
Suitable for continous relief when pressure
reduction compared to standard non-AC
exceeds a set point. Limits pump pressure
valves.
on low flow. May be combined with by-pass
pump control.

PFC - Pressure/Flow Control Valve Constant Pressure


A patented pressure reducing valve that increases at distant point
the controlled downstream pressure as flow PFC adjusts downstream
increases. The maximum increase in pressure is pressure to compensate
adjustable from zero to 30 psi (2 bar) above base for pressure drop.
pressure. Simple hydraulic action, will operate Constant pressure is
normally while submerged. Requires no electrical maintained at a remote
supply or batteries. location during low or high
demand.

Reduced Leakage Loss


in Aging Systems
Leakage is directly proportional to
pressure.
low demand = low pressure
high demand = increased pressure.

PR-SM - Pressure Reducing with Integral Back-up


Combines patented GEMINI valve with pilots that continue to control the
downstream pressure, despite a failure that in a normal pressure reducing
valve would result in downstream pressure rising to inlet pressure. If
monitored, a primary malfunction will alert the control station to attend the
valve as soon as convenient, meanwhile the valve continues to operate.

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963
ValvesSensorsSystems measurIT technologies

Discover The Singer Valve Difference

Save bent stems, inspection and assembly time


(Removable, separate stem cap)

Prevents rust and reduces maintenance


(Stainless steel external fasteners)
Corrosion resistant
Easy safe removal of inner (316 Stainless steel spring)
valve assembly Easier maintenance
(Lifting eye bolts pro- Improve worker safety
vided on rolling diaphragm (Smaller lighter cover)
models)

Chlorine & chloramine


resistant
(Buna-N and EPDM
Easy bonnet removal
Elastomer Diaphragm
(No rusting spigot / lip locations)
available)

Dependable maintenance-free
seat
(Stainless Steel
Improve anti-vibration fasteners)
flow, wear resistance
(fusion epoxy lined
and coated)

Easy re-orientation of
pilot system
(Extra threaded taps
on main valve)

Easy disassembly of inner valve


(Accessible wrench flat on flat Corrosion resistant stem
diaphragm models) (316 Stainless steel)

Maintenance free and


Unequalled low flow stability Guaranteed for life
(rolling diaphragm design; 10” [250mm] and larger) (316 Stainless steel seat ring)

Sizes: Flows from:


1/2” to 36” 1 to 35,000 USgpm • 100% Factory Tested • Meets regulatory requirements*
(13mm to 900mm) (0.06 to 2,210 L/s)

* Not available in all size/model combinations. Consult with MeasurIT.

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963
ORDER / QUOTATION INFORMATION:
Customer contact: _______________________________________________________ Job No.: __________________________________________________________________
Company name & address: _________________________________________________ Phone: _____________________________ Fax: ______________________________
_______________________________________________________________________ Email: __________________________________________________________________
Model (i.e. PR, RPS): ______________________ END CONNECTIONS:
Series: □ 106 - full port □ 206 - reduced port □ ANSI FNPT □ ANSI 150 □ ANSI 300 □ BSPT
Valve size: _________________________ □ inches □ mm □ ANSI drilled to PN10 □ ANSI drilled to PN16
Quantity: _________________________ □ ANSI drilled to PN25 □ ANSI drilled to PN40
Fluid being handled: _______________________________________________________ other: ___________________________________________________________________
ValvesSensorsSystems

VALVE PATTERN: PILOT SYSTEM ORIENTATION:

Craan, Craanford,
GLOBE PATTERN ORIENTATION ANGLE PATTERN ORIENTATION STANDARD OPPOSITE

Gorey, Co. Wexford, Ireland


MeasurIT Technologies Ltd.
□ □ □ □ □ □ □ □
NOTE: Horizontal stem - full port available up to 8’’ only; NOTE: Horizontal stem - full port available up to 8’’ only;
reduced port available up to 10’’ only. reduced port available up to 10’’ only.

APPLICATION DETAILS: FLOW RATE: DIFFERENTIAL PRESSURE RANGE: FLUID TEMPERATURE:


□ USGPM or □ L/s Min.: __________________________ Inlet: _______________ Outlet: _______________ Min.: ___________________
□ PSI or □ bar Normal: __________________________ Inlet: _______________ Outlet: _______________ Normal: ___________________
other: ______________________________ Max.: __________________________ Inlet: _______________ Outlet: _______________ Max.: ____________________
ELECTRICAL (WHERE APPLICABLE): MAIN VALVE OPTIONS: PILOTS & ACCESSORIES:

www.measurIT.com
Solenoid voltage: ________________________________ □ reclaimed water Pilot spring range: ____________________

email: info@measurIT.com
Pilot range(s): __________________________________ □ external spring lift Required operating range: ______________
Energize to: □ open □ close main valve □ grooved ends Pilot utilized: _________________________
Number of limit switches: _________________________ □ internal drop check
Actuation positions: ______________________________ □ anti-cavitation trim □ model J0097A strainer
Contacts: □ SPDT or □ DPDT □ x107 position indicator □ model J0098A strainer
□ Standard power-failure mode is fail at last position or □ x129 limit switch indicator □ arion model J1521G strainer
□ Fail open on power failure or □ x136 analog position transmitter □ arion model J1521M strainer
□ Fail closed on power failure □ no yellow metal upgrade
Source of set point signal (4-20mA): _______________ □ delrin stem sleeve OTHER INFORMATION:
Source of set process variable signal: ______________ □ oxy nitride stem ____________________________________
□ Optional explosion proof housing OTHER:

Fax: +353 (0) 53 942 8963


____________________________________

Phone: +353 (0) 53 942 8962


□ Optional NEMA 4x control panel enlosure Controls flow □ in □ out of reservoir ____________________________________
measurIT technologies

□ Optional touch screen operator interface

Potrebbero piacerti anche