Sub: Quotation for Condition Monitoring of Transformer, CT/CVT and Relay Testing.
Ref: Youre Email Dated 16/12/2015.
Shaan Energy aims to be a leading Organization in Condition Monitoring Tests on Power Equipments.
We have been able to cater to our customers needs in a very streamlined and organized manner. We
have always targeted on effective Execution of the Work, placed by our customers and this along with
other factors has enabled us to carve a niche for ourselves in the market.
We have sophisticated Automatic Testing Equipments, Omicron CT/PT Tester, Omicron Tan
Delta Kit, Omicron Digital 3 Phase Relay kit for any type of relay Testing.
We are enclosing the Quotation for the above work.
We hope that you will find our rates, quite comparative and reasonable. We are expecting favorable
Orders for carrying out the above work.
Assuring you our best service always.
Thanking you.
Yours faithfully,
For Shaan Energy,

(Executive Director)

1. 132KV CONTROL SYSTEM AT MRSS & MAHADEO PUR GRID:


No of
Units

Total
Amount

6,000/=

120

7,20,000/=

Testing of 145KV CTs, Type IT, 145KVx24No. Testing for


Insulation, Resistance, and Ratio & Polarity test.

5,000/=

24

1,20,000/=

3.

Testing of 145KV CVTs x18 Nos., Insulation & Healthiness


Test. Make : Alstom

5,000/=

18

9,0000/=

4.

Testing of Surge Arrester 18Nos. Insulation & Healthiness


Test. Make : CG

4,000/=

18

72,000/=

Condition monitoring & health checking of all Earth Pits at


MRSS & Mahadeo pur.

30,000/=

Lot

30,000/=

5.

Sl.
No.
1.

2.

Rate Rs
Per Unit

Particulars

Testing of all protection system by primary & secondary


Injection, Healthiness and Operational check of all Relays.

10,32,000/=

2. 11KV CONTROL SYSTEM AT


Sl. No.
1.

2.

3.

MRSS

Particulars

Testing of all protection system by primary &


secondary Injection, Healthiness and
Operational check of all Relays. = 65 Nos.
Make: Alstom
800Amp.VCB for 11KV Incomer system 02Nos.
Make: Alstom
630Amp.VCB for 11KV Out Going System08Nos.
Make: Alstom

Rate Rs Per
Unit

No of
Units

Total
Amount

6,000/=

65

3,90,000/=

5,000/=

02

10,000/=

5,000/=

08

40,000/=

4.

PTs. 02Nos. Insulation & Healthiness Test.


Make: Alstom

5,000/=

02

10,000/=

5.

Bus coupler, 01No. Checking of control &


operational
Make: Alstom

20,000/=

01

20,000/=

4,70,000/=

3.Tests on Transformer of 12.5 MVA :


Sl.
No.
1.

Particulars

Rate Rs Per
Transformer

No of
Units

Total
Amount

1,50,000/=

1,50,000/=

1. Winding Ratio test by Ratio meter.


2. Winding Resistance test by Ohm meter.
3. No load magnetizing current test.
4. Partial short-circuit test of winding.
5. Vector group & polarity test of winding
6. Insulation resistance test by motorized megger.
7. Magnetic core balance test.
8. Earth resistance test
9. CTs Polarity test of Transformer.
10. Test of Buckkolze relays.
11. Ten Delta Transformer Bushing
12. Oil test of main tank. i- BDV test
Ii-Acidity test
Iii-Water content in ppm.
Iv-Sludge content test.
V-Density, Viscosity, Volume resistivity, superficial test
Vi-GDS test.
13. Condition monitoring & health checking of On Load
tap changers.
14. Condition monitoring, health checking &
adjustment of all interlocks of monitoring device of
Transformer.

1,50,000/=

4. Make of Equipments used for Testing:


Sl. No.
1.

2.

3.

Particulars
Insulation Resistance (IR),
Polarization Index (PI).
DC Absorption Test.
Capacitance & Tan Delta Test (On Transformer
Insulation), Bushing and CT/PT.
Leakage Current Test
Excitation Current
Short circuit Impedance Test on Transformers
Transformer Ratio and Phase Angle error Test (All Taps),
Winding resistance and OLTC tap changer Test (All Taps)

Name of Testing Kit


Motwane or Kyoritsu Japan

Omicron CPC100 +CP TD1

(Made in Austria fully


automatic testing Kit)
Omicron CPC100

4.

Ratio (Primary Injection) on CTs.


Winding resistance on CTs.

5.

Open and Close timing

6.

Contact Resistance

Omicron CPC100

7.

Relay Test Kit

Omicron CMC 356

Omicron CPC100
Scope Timer kit

Commercial Terms and Conditions:


1. Payment: Payment immediately after submission of Test Report & Bill (With in 15 days).
2. Service Tax: As Applicable.
3. Validity: The Rates Quoted is firm and open for acceptance for a period of 30 days.
4. Transportation Charges 40,000/= Extra.
5. Boarding and Lodging should be provided to our Engineers.
6. Idle charges Rs 15,000/= per Day.
General Terms and Conditions:
1.We have Mobile-Testing Team for Condition Monitoring Tests on Transformers.
2.Shutdown is required for Condition Monitoring Tests on Transformers and CTs/PTs.
3.Dis Connection and Connection in your scope. Sufficient Helpers should be provided.
4.One Engineer should co-ordinate during testing.