Product data sheet

catrone

MicaFlex Microcontroller-based differential


pressure and flow transmitter with digital
indication

MF-FD
version 3.x
md-1328gb / 2009-03-16

Application
MF-FD is a pressure transmitter designed for flow
measuring.

Output signal in Volt and mA


Selectable flow linear display and
output or pressure linear display and
output
Forced output signal
Easy One-Key zero-setting
Calibration certificate attached

Pressure connections
Pressure connections should be made with
Micatrone mounting kits for safe and tight function.
Connect the measurement outputs with HT-plastic
tube 8/6 mm.
MF-FD is fitted with a 4-digit LED display.

Zero adjustment
Press down the "zero-setting"-button until the LED
turns off. Release the button and the zero-setting
is finished.

Output signal setting


The Volt/mA-output signal has different terminals.
Set Volt/mA signal by miniature switch, connect to
selected terminal.
D7

AC9 IC9 R33


FM1

R18
R13
R16

C8

C18

R15
R12

ESC
R19
R22
LED102R17
T1
D2
C5
D102
T2

LED

SW1

R101

SW2

D104

IC4

INC

DEC

R48

C7

C17

C10

R21

R14 D1

D103

C11
R27 R28

R11 C9

R23

PGM

LED101
IC5

IC1

C3

C6

C13

J2

K3
VDR1

C21

G G0G0OutOut
(+)(-) (-) V mA
FM2

AB Micatrone
P3778 v3.01
Top Silk

PL2

DIL1 *
1 RANGE
2 TEST
3 OUTPUT
4 DAMPING
5 DAMPING
* see cover

R43

PL1

DIL1

ZERO

Zero-setting button

FM3

The measuring range can be adjusted to correct a


measuring deviation. Instruction can be found on
our web site, www.micatrone.se.
MF-FD is programmable with 4 keys on the display unit and include programmable parameters
for flow indication, number of decimals and the
alarm function. For flow indication, values below
9999 can be displayed, decimal point can be set
for up to 3 decimals, e.g. 9.999.

LED1
ZERO

R44

Adjusting the measuring range

Programming, flow indication

R47

R20
D101

DIG4

R8
R10
C23

SW3

D105R26SW4

SNAP1

miniature switch

AC1

DIG3
C1 C2

AC7D

R45

C15
FM3 R24 T3

D4

R5

Depending on the selected output signal, 0...10


volt or 4...20 mA, the max output signal is obtained when miniature switch no 1 is set to position
"ON". This function can be used to check the receiving system

K4

H2

8888
AC7A

R1

C14
C16

LED103

K1

C4 R9 R7
AB Micatrone
C101 P3761
R112
C24 Top Silk

TG1

LED105

D3

R41

R111

J101
R25

C12 R29

LED104
R2

RP102
RGND

R38

DIG2 AC3

C102

R6

K101

K2
J1

DIG1

R46

C19
IC101
D5

Forced output signal

R30

FM2

RP101

R39

R31

IC3 R4

AC8

R42

IC6

R109

FM1
R40

R110

AC2

IC2

Adjustment keys 5 6.

R34

IC7
R102

H1

IC8

R32
R37

C22 C20

D6

R35

Setting of damping
The MF-FD offers a possibility to set different
damping (time constant). At delivery the damping
is set to 1,50 seconds damping.

Display unit

R36

AB MICATRONE 2009-03-16 [h: \ appdok \ typeset \ datablad \ md-1328gb_090316.vp]

Selectable damping

Alarm function
MF-FD include a visual alarm indicated by a
flashing display on alarm state if this function is activated. By using an optional plug-in module, a potential-free changing relay output can be obtained.
Alarm can be set for high or low flow/pressure.
A time delay can be set for 0...600 seconds.

Technical data

Service
MF-FD needs normally no service, but we recommend to check the zero point once a year.

24 15% VAC, 20...32 VDC


24, 115, 230 (with transformer), 50/60 Hz
Max. 3 VA (24VAC)
Max 6 VA (230VAC)
0...50 Pa
0...100 Pa
0...200 Pa
0...500 Pa
0...1 kPa
0...2 kPa
0...5 kPa
Other ranges on request.

MF-FD should be cleaned with a soft cloth and a


light detergent. Do not use scouring powder or
dissolvent.

Transformer (Optional)

50 kPa
4...20 mA max RL = 400 W
0...10 Volt Ri = 0 W
Ambient temp.:
0...55C
Accuracy:
Max error 0,5% of the full
range plus 0,5 Pa.
Temp.drift:
Max. 0,5 % per 10C
Damping:
Selectable; 0.05, 0.7, 1.5 or
2.2 s
Degree of protec.: IP 65
El. connections,
-rigid cable:
1 x 2.5 mm2 / terminal
-flexible cable:
1 x 1.5 mm 2 / terminal
Cable entries:
2 st threaded holes M16x1,5
(cable glands not attached)
Pressure. conn.: 8/6 mm HT-plastic tube
Dimensions:
WxHxD = 122x120x90 mm
Weight:
0,53 kg

Accessories
Mounting kit VR-DR
HT-plastic tubing 8/6 yellow, per meter or

roller 50 m
Manifold valve 2-TK
MFM-PANEL (wall/cabin-door) mounting kit
MFM-DIN Mounting kit for DIN-rail
MFM-L1 ver 3, Alarm module
Transformer 24, 115, 230 VAC, built in

RoHS

EU Compliences:
EMC
SS-EN 50081-1
SS-EN 50082-2
LVD
SS-EN 610101-1

G0 [-]

Out [V]

AB Micatrone
ldermansvgen 3
SE-171 48 SOLNA
SWEDEN

Connection with transformer


(Transformers available for 24/115/230 VAC)

Out [mA]

G [+]

G0 [-]
G0 [-]

Connection 24 VAC / 20...32 VDC


(without transformer)

COMPLIANT

Telephone:
Fax:
Internet:
E-mail:

Max. load:
Output signal:

+46 8-470 25 00
+46 8-470 25 99
www.micatrone.se
info@micatrone.se

web reference - http://www.micatrone.se/prod_detail.php?secID=2&lang=gb&id=62

AB MICATRONE 2009-03-16 [h: \ appdok \ typeset \ datablad \ md-1328gb_090316.vp]

The output signal is normally NOT galvanically separated to the supply voltage. To obtain galvanic
separation between the output signal and the supply voltage on a standard transmitter, the apparatus must be equipped with a plug-in transformer.

Range:

Cleaning

Out [mA]

Power cons.:

Out [V]

Supply voltage:

Potrebbero piacerti anche