Specifications:

1) Refrigerant used
2) Volume of water in the evaporator tank
3) Energy meter constant

: R-12
: 10 liters
: 3000 rev / Kw hr

4) Pressure gauge capacity

: 0-150 lb/in2 in 2 numbers

5) Pressure gauge capacity

: 0-300 lb/in2 in 2 numbers

6) Thermometers used

: 0-1000C in 4 numbers

7) Model

: 412

8) Compressor

: 1/3rd HP

9) Rated voltage

: 220V, 50 Hz single phase

10)

Drier

: DM50

11)

Fan capacity

: 1/8th HP, 230V,1350rpm

Department of Mechanical Engineering


Engineering, Ramanagara

Ghousia College of

HEAT AND MASS TRANSFER LAB


Experiment: Composite Wall Apparatus
Specifications:

1) Heating Coil

: 200W

2) Dimmer stat

: 2A,240V

3) Ammeter

: 5A

4) Voltmeter

: 200V

5) Digital temperature indicator

:8

6) Thickness of each slab

: 25mm

7) Breadth and height of each slab

: 50mm

Department of Mechanical Engineering


Engineering, Ramanagara

Ghousia College of

HEAT AND MASS TRANSFER LAB


Experiment: Parallel and Counter Flow Heat Exchanger
Specifications:

1) Diameter of inner pipe

: 54mm

2) Length of test tube junction


3) Digital temperature indicator
4) Rota meter capacity
5) Specific heat of water

: 1000 mm
:4
: 0- 1.4 LPM
: 4.187 Kj/Kg K

Department of Mechanical Engineering


Engineering, Ramanagara

Ghousia College of

HEAT AND MASS TRANSFER LAB


Experiment: Transient Heat Conduction
Specifications:

1)

Diameter of meat rod

2)

Thermal conductivity of rod

3)

Specific heat of rod

: 385 Kj/Kg K

4)

Density of rod

: 8954 Kg/m3

5)

Digital temperature indicator

:7

6)

Length of test junction

: 450 mm

7)

Spacing between the thermocouples

: 57 mm

8)

Voltmeter

: 0-100/200V

9)

Ammeter

: 0-2A

10)

Rota meter capacity

: 5 LPM

: 35 mm
: 386 W/m k

Department of Mechanical Engineering


Engineering, Ramanagara

Ghousia College of

HEAT AND MASS TRANSFER LAB


Experiment: Stefan Boltzman Apparatus
Specifications:

1) Diameter of hemispherical enclosure

: 200mm

2) Diameter of water jacket

: 260mm

3) Height of water jacket

: 160mm

4) Diameter of base plate (Bakelite)

: 240mm

5) Diameter of sleeve

: 44mm

6) Diameter of test disc

: 20mm

7) Mass of test disc

: 5.5gms

8) Specific heat of test disc


9) Number of thermocouples mounted on enclosure

: 0.38 KJ/Kg K
:4

10)

Number of thermocouples mounted on Disc

:1

11)

Temperature indicator-digital type

: 0-2000C

Department of Mechanical Engineering


Engineering, Ramanagara

Ghousia College of

HEAT AND MASS TRANSFER LAB


Experiment: Thermal Conductivity of Metal Rod
Specifications:

1) Length of metal rod


2) Diameter of metal rod

: 425mm
: 38mm

3) Test length of the metal rod


4) Number of thermocouples mounted on metal rod

: 200mm
:5

5) Heater coil band type

: Nichrome heater

6) Cooling water diameter

: 90mm

7) Temperature indicator

: 0- 3000C

8) Voltmeter

: 0-100/200V

9) Ammeter

: 0-2 Amps

Department of Mechanical Engineering


Engineering, Ramanagara

Ghousia College of

HEAT AND MASS TRANSFER LAB


Experiment: Natural Convection
Specifications:

1) Diameter of the tube

: 38mm

2) Length of the tube

: 500mm

3) Duct size

: 20cmx20cmx1m

4) Number of thermocouples mounted on tube

:7

5) Thermocouple for measurement of air temperature

:1

6) Temperature indicator

: 0- 3000C

7) Dimmer stat

: 2A,260V

8) Voltmeter

: 0-100/200V

9) Ammeter

: 0-2 Amps

Department of Mechanical Engineering


Engineering, Ramanagara

Ghousia College of

HEAT AND MASS TRANSFER LAB


Experiment: Forced Convection
Specifications:

1) Outer diameter of pipe

: 32mm

2) Inner diameter of pipe

: 28mm

3) Length of test section

: 40cm

4) Blower

: 1Hp

5) Orifice diameter
6) Dimmer stat

: 13.8mm
: 2A,260V

7) Voltmeter

: 0-100/200V

8) Ammeter

: 0-2 Amps

9) Heater coil band type


heater

Nichrome

Department of Mechanical Engineering


Engineering, Ramanagara

Ghousia College of

HEAT AND MASS TRANSFER LAB


Experiment: Emissivity Measurement Apparatus
Specifications:

1) Test plate diameter

: 160mm

2) Black plate diameter

: 160mm

3) Heater coil band type

:Nichrome heater

4) Dimmer stat

: 2A,260V

5) Voltmeter

: 0-100/200V

6) Ammeter

: 0-2 Amps

7) Enclosure

: 58cmx30cm

8) Number of thermocouples used

:3

9) Temperature indicator

: 0- 3000C

Department of Mechanical Engineering


Engineering, Ramanagara

Ghousia College of

FOUNDRY AND FORGING LAB


Experiment: Sieve Analysis of Base Sand Test
Specifications:

1) Number of sieve plates

: 10

2) Sieve plate number 1 in size

: 1700 Microns

3) Sieve plate number 2 in size

: 850 Microns

4) Sieve plate number 3 in size

: 600 Microns

5) Sieve plate number 4 in size

: 425 Microns

6) Sieve plate number 5 in size

: 300 Microns

7) Sieve plate number 6 in size

: 212 Microns

8) Sieve plate number 7 in size

: 150 Microns

9) Sieve plate number 8 in size

: 106 Microns

10)

Sieve plate number 9 in size

: 75 Microns

11)

Sieve plate number 10 in size

: 53 Microns

Department of Mechanical Engineering


Engineering, Ramanagara

Ghousia College of

FOUNDRY AND FORGING LAB


Experiment: Universal Sand Testing Machine
Specifications:

1)

Dry Compression strength

: 7000 gm/cm2

2)

Dry Shear Strength

: 5500 gm/cm2

3)

Green compression strength

4)

Green shear strength

1. (2NUMBERS IN 9CM height and 33cm width )

: 1380 gm/cm2
: 1100 gm/cm2

HEAT AND MASS TRANSFER LAB

2. ( 2numbers In 3inch and 12 inch)


ABDUL RAB H.R
Administrative Officer (Admin)

G.S.PRABHUNANDAN
Assistant Professor

B.S.MAHESH
Associate Professor

Potrebbero piacerti anche