Sei sulla pagina 1di 24

Centrifugal Ceiling and Cabinet

Exhaust Fans
Models SP and CSP

January

2010

Ceiling and Cabinet Exhaust Fans


Great things come in small packages, as do our ceiling fan SP models and cabinet fan CSP models. Be
assured when you buy any Greenheck product, you are getting a quality product at a competitive price.
In fact, we guarantee our ceiling and cabinet exhaust fans with a three-year warranty. We offer the most
comprehensive ceiling and cabinet exhaust fan line in the commercial market. We are your market leader!

Benefits
Lowest sound in the industry
Compact size
Five different fan styles offering you a competitive price
Broadest performance selections in the industry

CSP fans are designed for inline


remote mounted applications.

SP fans are designed for


ceiling mounted applications.
Greenheck Fan Corporation certifies that
the SP models shown herein are licensed
to bear the AMCA seal. The ratings shown
are based on tests and procedures
performed in accordance with AMCA
Publication 211 and AMCA Publication
311 and comply with the requirements of
the AMCA Certified Ratings Program.
The SP models are not AMCA certified
with 50 hertz motors.

Greenheck Fan Corporation certifies


that the CSP models shown herein are
licensed to bear the AMCA seal. The
ratings shown are based on tests and
procedures performed in accordance
with AMCA Publication 211 and
comply with the requirements of the
AMCA Certified Ratings Program.
The CSP models are not AMCA
certified with 50 hertz motors.

Models SP and CSP are listed electric fans


(UL/cUL 507). Ceiling Exhaust Fans are also
UL Listed for above bathtub/shower with GFCI
branch protected circuit. File no. E33599.

Quick Delivery and Quick Build Programs


Order from hundreds of SP and CSP configurations, accessories and thousands
of other products that can ship to your job site in less than 24 hours. We have
strategically located warehouses across the United States and internationally to fill
your request at a moments notice.
For other sizes and configurations where rapid response time is required, our Quick
Build (QB) program manufactures and ships your custom products in one, three,
five, or ten days.

Leading Edge Technical Support


When you need extensive product information look no further. Greenheck
products are supported by the industrys best product literature, ranging from
catalogs, installation, operation and maintenance manuals (IOMs), electronic
media, computer aided product selection (CAPS) program and more. Youll also
find this information on our web site at www.greenheck.com
Count on personal service and expertise from our national and international
representative organizations. To locate your nearest Greenheck representative,
call 715-359-6171 or visit our web site at www.greenheck.com

Model Comparison
Model and
Performance
Pages

Premium Ceiling
Fan: SP-A
page 16

Deluxe Ceiling
Fan: SP-B
page 17

Economy Ceiling
Fan: SP-C
page 17

Premium Inline
Fan: CSP-A
page 18

Deluxe Inline
Fan: CSP-B
page 19

Description

Profile
(minimum
height)

In the top of its


class when it comes
to meeting sound
requirements.

1012 inches
(267 mm)

Compact enough for


almost any application.
If quiet is what you
are after, this fan will
accommodate your
needs.

61516 inches
(176 mm)

Sound
(minimum
sones)

Air Volume
(maximum)

UL Listing

0.7

1,607 cfm
(2730 m3/hr)

UL Listed for above


bathtub/shower
with GFCI branch
protected circuit
(Sizes A390 and
smaller)

1.4

197 cfm
(335 m3/hr)

UL Listed for above


bathtub/shower
with GFCI branch
protected circuit

UL Listed for above


bathtub/shower
with GFCI branch
protected circuit

Designed for
light commercial
applications.

358 inches
(86 mm)

2.9

52 cfm
(88 m3/hr)

Outperforms the
competition and is
preferred by specifying
engineers.

1012 inches
(267 mm)

0.8

3,778 cfm
(6419 m3/hr)

UL/cUL Listed

Compact and designed


61516 inches
to fit in small remote
(176 mm)
quarters.

2.0

186 cfm
(316 m3/hr)

UL/cUL Listed

Standard Construction Features


Model SP-A
2

7
8

11

Model SP-B
1

2
3

12

12

11

10
9

9
8

10

4
1

Model SP-C
2

11
10
3
12

Model CSP-A
6

Model CSP-B

2
7

4
1
4

12

7
11
3

11
10

12

13
13

10

Standard Construction Features


#

Standard Construction Features

SP-A

Specific Features for Each Model


SP-B
SP-C
CSP-A
CSP-B

Prevents unwanted backdrafts

Spring loaded aluminum to eliminate


rattling and backdrafts
Round - For quick and easy
connections
Square - For quick and easy
connections

Removes quickly for maintenance

Includes conversion from horizontal


to vertical discharge
Vertical electrical access to eliminate
drilling holes
External electrical access to eliminate
removing motor pack, saving
installation time

(horizontal or vertical)

Eliminates drilling holes

Acoustic
Insulation

Absorbs sound

Disconnect

Servicing is quick and safe

Electrical
Junction Box

Large for easy wiring

Attractive Grille

Concealed attachment screws


securely fasten grille to housing for
quiet, rattle free operation

Mounting
Brackets

Adjustable for multiple installation


conditions

Embossed galvanized steel for rigidity

Backdraft
Damper

Outlet

Power Assembly

Electrical Access

Electrical
Knockouts

10

11 Housing

A low profile for height restricted


areas

Prepunched Prepunched

Prepunched

60 cycle,
115v only

All motors are compatible for use


with speed controls and have thermal
overload protection
12 Motors

Domestic & International


50 cycle, 220v or 240v
60 cycle, 115v, 208v, 220v, 230v, &
277v options

(See CAPS for availability)

13 Access Panel

Gain easy access to internal


components once installed

Exclusive
Electrical Wiring
Feature

Electrical access cover located on the housing exterior. This feature permits external wiring
without removing the power assembly, saving installation time and cost. Available on models
SP-A and CSP-A.

Double Wide
Fans

Available for applications requiring 700 cfm or greater.


Double wide fans have two double width forward-curved
wheels, which are housed in separate scrolls, and driven by
a single motor. Available on models SP-A and CSP-A.

Vertical
Discharge

Exhaust outlet duct installed in the optional vertical position. The power
assembly must be rotated to match the duct adapter position. Available
on models SP-A and CSP-A.

Options and Accessories


Ceiling Radiation Damper

Contractor 4 Packs

The National Fire Protection Association (NFPA)


Standard 90A requires openings in fire rated ceiling/
floor assemblies to be protected by appropriately
rated ceiling radiation dampers. As a result, many
local codes require fans installed in fire rated
ceilings to be protected by dampers which are
insulated against both heat and flame.

Save installation time and labor by installing


the housing first, then installing the internal
components after the sheetrocking, plastering and
finishing is done. Housings are packaged in one
box, power assemblies and grilles are packaged in
another box. Components are shipped to coincide
with the phase of your project. (Model SP-B only).

UL Classified ceiling radiation dampers are rated at


three to four hours of fire resistance. All model SP-A
fans and fan/light combinations are available with
ceiling radiation dampers. This design saves space
by allowing the damper to mount directly beneath
the fan.
Model SP-A

Round Duct Connections


SP-A Fan

4 inch - SP models: B50, B70 and B80

Hanging Vibration
Isolation

6 inch - SP models: A50, A70, A90, B90, B110,


B150, and B200

Ceiling Radiation
Damper
Fire
Rated
Ceiling

3 in.
Grille

AxB

Model SP-B

Round Duct Adapter


Optional - SP sizes A110 through A510

SP-B Fan
Hanging Vibration
Isolation
Ceiling Radiation
Damper
Fire Rated
Ceiling

3 in.
Grille

AxB

SP Model
A50 - A190
B50 - B200
A200 - A390
A410 - A510
A710 - A780
A700
A900 - A1550

CRD
310
320
350
700
360

Length
1312

Width
1118

Height
3

(343)

(283)

(76)

1438

1214

(365)

(311)

(76)

18716

141516

3
(76)

(468)

(379)

24316

1214

(614)

(311)

(76)

24316

141516

(614)

(379)

(76)

All dimensions shown in inches (millimeters). Add an L to all CRD models if


fan & light combo is used. *CRD is approximately 1/4 inch (6 mm) larger than
housing dimension. (See Installation, Operation and Maintenance Manual)

Wheel Options
Greenhecks ceiling and cabinet
fans (models SP and CSP) deliver
high performance from a forwardcurved wheel. The forward-curved
wheel design offers both highefficiency and low sound. Fan
wheels are constructed of plastic
or steel as standard, and all models
offer an aluminum wheel option.
Level A models utilize steel
or plastic wheel construction
depending on size.

Plastic

Steel

Level B models are standard with


a plastic wheel.
Aluminum

SP Grille and Lighting Options


Grille Options

Designer is the standard grille for


SP models A50-A390 and B50-B200.
Available in white plastic finish, with
or without motion detector or time
delay (see following pages for motion
detector and time delay information).

Decorative grille is optional on


A50-A390 and B50-B200. Available
in white plastic finish, with or without
light, motion detector or time delay
(see following pages for motion
detector and time delay information).

Aluminum grille is optional on


A50-A390 and B50-B200. Standard
on A410 and larger. Available in white
enamel finish.

Stainless Steel grille is optional on


A50-A390 and B50-B200. Available in
polished stainless steel finish.

Lighted Grille Options


Greenhecks fan and light combinations include
either a prismatic or a frosted lens and either
compact fluorescent or incandescent lamps. Our
unique light box is manufactured with a reflective
material to increase the light given off by either type
of lamp. UL Listed for above bathtub and showers
with GFCI branch protected circuit.
Model SP-A, sizes 50 - 390
Model SP-B, sizes 50 - 200
Prismatic Lens
The prismatic lens design provides
approximately 25% more light than
a traditional frosted lens. The lens
may be easily removed to replace
light bulbs.
Frosted Lens
The frosted lens option is a
traditional design which lets
approximately 80% of light through
the lens. The lens may be easily
removed to replace light bulbs.
Incandescent Lamps
One bulb provides up to 100 watts
of light (bulbs to be provided by
others).
Dimmable
Reflective light box

Compact Fluorescent Lamps (CFL)


Quick start bulbs (1 or 2 bulbs)
Reflective light box
Produce 90% less heat
Lower energy costs
Two 13 watt CFL bulbs equals
100 watts of incandescent light.
Bulbs are included.
A major advantage of using CFLs is to save money,
as shown in the table below. This table assumes the
light is on for six hours per day and the electric rate
is 10 cents per kilowatt-hour. This study was based
over a 41/2 year period.
27 Watt Compact
Fluorescent
Cost of Lamps

100 Watt
Incandescent

$14.00

$0.50

1,642.5 days (4.5 years)

167 days

$5.91

$21.90

10

Total Cost

$40.60

$103.55

Savings Over Lamp Life

$62.95

$0.00

Lamp Life
Annual Energy Cost
Lamps Replaced in 4.5
years

Source: U.S. Department of Energy, August 2001


Office of Energy Efficiency and Renewable Energy

Control Accessories
Speed Controls

Switches

Speed controls may be used


on model SP and CSP fans
for manual adjustment of the
fans performance (for final
system balancing) or to control
the fans output in confined
spaces, such as conference
or meeting rooms. The fan can be
adjusted to 60% of design airflow
with a speed control. This reduction
in airflow and fan speed is also
accompanied by a reduction in
Internal Mounting
noise level. Solid state speed controls
are available for a range of applications up to 15
amps. Speed controls can be used to operate more
than one fan if the combined total amperage of the
fans do not exceed the control rating.

Switches may be used on model


SP and CSP fans to enable manual
control of your fan or fan and light
combination. There are several
options to fit your application.

FULL VOLTAGE

Model MS-16 - Single pole rocker switch assembly


with cover and pilot light.
Rated for, 115v, 15 Amp, 1/2 hp
UL Listed
NEMA 1 - Two pole rocker switch assembly.
Rated for, 220/230/240/277v, 20 Amp, 2 hp
UL Listed
Requires a 2x4 handy box.

SWITCHED FULL VOLTAGE

RED

Dotted line indicates


for use with 10W
switch only.

BLACK

NEMA 1 - Single pole rocker switch


assembly.
Rated for, 115v, 15 Amp, 1/2 hp
UL Listed

AUX
DEVICE

WHITE
VARIABLE
VOLTAGE

SPEED CONTROL

EXTERNAL JUMPER

120 VAC

FAN

LOAD
N

LOAD

For use with shaded pole and permanent split


capacitor (PSC) motors. Available shipped loose or
mounted internal or external.
SPEED CONTROL INTERNAL AND/OR EXTERNAL MOUNTING OPTIONS
Model
Voltage Rating
Amp Rating

Fan Sizes
50

70

80

90 110 125 150 190 200 250 290 390 410 510 700 710 780 900 1050 1410 1550 1750 2150 3600

5WSSC
115 - 127v
5 Amp

I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E I/E

10WSSC
115 - 127v
10 Amp

15WSSC
115 - 127v
15 Amp

No

No

No

No

No

No

No

No

5W240
220 - 240v
5 Amp

No No No *I/E I/E No I/E I/E *I/E No I/E I/E No I/E No No I/E No

I/E

No

I/E

No

No

No

8WSSC
220 - 240v
8 Amp

No No No

No

No

No

No

No

No

No

No

No

No

5W277
227v
5 Amp
KEY:

*E

No

*E

No

No

No No

No

No No No No I/E I/E I/E I/E *I/E No No No No No No No No No


E = External mounted only

I/E = Available Internal and External Mounted

* Only available on the B-series (A-series is not available)

No = Not available

NOTES: Speed controllers are not available for 208v applications. SP-C50 Speed Controller is shipped loose only. All speed controller options listed in table are UL Listed.
Handy Box sizes are 2x4 for all options above except 10WSSC and 15WSSC, which are 4x4.

Control Accessories
Time Delay Switch

Motion Detectors

Time delay switches save energy by automatically


turning off equipment. They may be used with SP
and CSP fans or fan and light combinations for
extended operating time of fan. Time delay switches
act in the same manner as a standard switch,
however, there is a delay of 1 to 60 minutes after it
has been turned off.

Motion detectors may


be used with SP and
CSP fans or fan and light
combinations. Motion
detectors use a passive
infrared motion detector to
automatically turn the
fan on when a change in motion is sensed.
They have a viewing area of 180 degrees,
however they must be placed in the lineof-sight. They also have an adjustable time
delay shutoff setting of 1 to 20 minutes.

115 VOLT AC (HOT)


60 CYCLE

BLACK

BLUE

(500 Watt Max)


LIGHT

(7.5 Amps Max)


FAN MOTOR
RED

(NEUTRAL)
WHITE

Hot

Black

Motion Sensor

Black
White
Red

Hot

Green
Neutral

Gnd.
Red

Model GTD - A single switch controls both fan and


light. Available shipped loose.
Silent Operation
Rated for 115v
UL Listed
Requires 2x4 handy box

Transformers
Transformers are available for
applications requiring voltage
reduction. Selection is based on
motor amperage. All transformers
are shipped loose.

Models

Voltage Ratings

Neutral
Load
(12.5 Amps Max.)

Wall Mount

Fan Motor and/or


Light

Black
Green
White

Ground

Grille Mount

Grille Motion Detectors are available on models up


through size SP-A390 and SP-B200.
Rated for 115v
UL Listed
Model MDW
For use on fan or lights. Available shipped loose.
Rated for 115v
UL Listed
Requires 2x4 handy box

Amp Ratings

T-2.0

230/277v to 115

2.0 Amps

T-4.3

230/277v to 115

4.3 Amps

T-6.5

230/277v to 115

6.5 Amps

T-8.6

230/277v to 115

8.6 Amps
277 V SUPPLY

SWITCH BOX
BLK

BLK

BLK

H1

H2

H3

277V TO 115V TRANS.


750 VA
X1
RED

X2
RED

SWITCH

115 V MOTOR

Filters and Discharge Accessories


Filters

Roof Discharge Accessories

Fans used in most applications will collect airborne


dirt on wheels and motors over time, even where air
Model RJ - Pitched Roof Cap
is not excessively dirty. Accumulations of dirt on the
Steel construction with black enamel finish
fan wheel will sharply reduce performance and cause
Integral flashing flange
imbalance. Dirt buildup on the motor can cause it
to overheat. All of these conditions will shorten the
Built-in birdscreen and damper
life of the fan. To help reduce this accumulation,
RJ-4 and RJ-6x9
washable aluminum mesh filters are available to trap
D
dirt before it enters the fan. These filters should be
C
E
regularly cleaned to maintain performance. The Filter
Loss Chart shows the effect the filter will have on
performance. To determine the added resistance,
divide the desired cfm by the filter area (ft2). This will
A
give FPM. Use this with the filter loss chart to get
B
the added resistance. Filters reduce sound levels, in
addition to reducing dirt accumulations on the motor
and wheel.
RJ-10x10
RJ-4 and RJ-6x9
D

RCC-7

E
A

RFC

E
A

Mesh
Filter

Model

SP
Grille

RCC-7

.22

Dia.

.16

C50, B50-B80

RJ-6x9

B90-B200, A50-A390

1.5

.12

(38)

.10

(476) (362) (368) (264) (165) (152 x 229)

1812 2712 1534 2358 912

B
C

Model
EL-10x3
- Elbow
Discharge with
D
1/4-20
Dia.
D
hanging
Grille
support
rod by
Dia.
A installation under roof eaves
Designed
for
others

.06

Built-in damper

.04

For model SP and CSP sizes 50-290


A
0

SP Model

3
4
5
6
Velocity FPM x 100

1/4-20
hanging
Filtersupport
Loss Chart
rod by
others Filter Model

SP-A50 - A190
SP-B50 - B200, A200 - A390
SP-A410 - A510
SP-A710 - A780
SP-A900 - A155

C
1.75
A C(44)

11.125
B(283)

10

(254)

3.5 (89)
A C
2.875 (73)

Filter

Designer
Grill
F-200
F-200

*Metal
Grille
F-210
F-220

Area (ft )

NA

F-250

1.518

NA

F-260

2.078

*Aluminium or Stainless Steel Grille.

10 x 10

(470) (699) (400) (600) (241) (254 x 254)

.08

.00

A
Throat

4 (102)
(279) (235) (210) (135) (114) diameter
GRS 6 x 9
1834 1414 1412 1038 612

Painted steel louvered grille

.02

6.5 (165)
1.625 (42)
C
E (86)
3.375

0.739
0.911

9.375
(238)

C
A

E
5.125

914 814 5516 412

All dimensions shown in inches (millimeters).

.14

11

.18

Resistance in w.c.

RJ-10x10 A410-A1050

.20

10

(38)

A sizes:
For use with

Dia.

1.5

RJ-4

RFC

.24

C
DB

Dia.
A

11.5 (292)

(130)

All dimensions shown in A


inches (millimeters).

6 (152)
dia.

E
A

Flat Roof CapsAA

C-7

E
B

Model RCC-7
- Curb Cap
RFC
B

d RJ-6x9

Dia.
A

Weathertight aluminumRCC-7
construction
B
Integral birdscreen
RJ-10x10 B
Built-in curb cap
Droof curb
C
C
Requires
C
D
D
Dia.
1.5
(38)
Dia.
A
E

Model

1.5

(38)

with all
A
B
C
D
sizes:
RCC-7 50-390
15 (381) 12 (305) 10 (254) 638 (162)
BAll dimensions shown in inches (millimeters).

A
RFC

Model GRS - Curb Cap

6 (152)
dia.

D
B

6.25A

Dia.

6.25

(159)

Unit Size

C
B50-B200
412 (114)
D
A50-A190
512 (140)
A200-A390
1.75 (44) 634 (171)
Dia.
A410, A510,
A710,
A780
914 (235)
A
C
A700
512 (140)
A900-A1050, A1410-A1550
914 (235)
A1750, A2150
914 (235)
E
A3600
914 (235)
All dimensions shown in inches (millimeters).

1558 (397)
1458 (371)
151Dia.
2 (394)
1958 A
(498)
2518 (638)
2538 (645)
3634 (933)
4858 (1235)

6.25
E

C
A

A C

4 (102)
dia.
GRSF

GRS
6 (152)
dia.

(159)

Dia

1/4-20
hanging
support
rod by
F
others

B
(159)

dia.

4 (102)
dia.

For use
Throat
Model
with all
A
B
C
D
Dia.
sizes:
RFC-7
50-390
18 (457) 12 (305) 10 (254) 638 (162) 7 (178)
All dimensions shown in inches (millimeters).
4 (102)

(38)

1/4-20
anging
upport
rod by
others

B B

Throat
Dia.

C
1.5

RFC
dia.
construction

C
E D
Dia.
C
B
1.5
Vibration isolator
A C kits areE available for suspended
(38)
installations.
Kits
include
all
hardware
necessary
A
C
C
A
C
D
to
mount
one
unit,
with
the
exception
of
1/4-20
D
D
threaded rod to be supplied by others. Fan
A
RJ-10x10
1.75 (44)
Dia.
mounting brackets
include prepunched
mounting
D
E
D
A of installation.
C holes for ease

1014 (260)
1214 (311)
16516 (414)
20516 (516) B

RFC

Hanging Vibration Isolators

C
A C B
Model RFC-7 -E Flashing
Flange
6 (152)

Dia.

7 (178)

GRSF

For use
with all
A
B
C
D
sizes:
GRS-10 410-710
19 (483) 2012 (521) 614 (159) 3 (76)
E 314 (83)
GRS-12 780-1050 22 (559) 29 (737) 778 (200)
A
GRS-16
1410-2150 26 (660) 29 (737) 834 (222) 334 (95)
BB
GRS-20 3600
30
(762) 3512 (902) 914 (235) 414 (108)
A
All dimensions shown in inches (millimeters).

D
D

sizes:
GRSF-10 410-710
23 (584) 2012 (521) 614 (159) 3 (76) 1014 (260)
RCC-7
GRSF-12 780-1050 26 (660) 29 (737) 778 (200) 314 (83) 1214 (311)
GRSF-16 1410-2150 30 (762) 29 (737) 834G(222) 334 (95) 16516 (414)
B
GRSF-20 3600
34 (864) 3512 (902) 914 (235) 414 (108) 20516 (516)
D
All dimensions shown in inches (millimeters).
F

B aluminum exterior construction


All
1/4-20
A C
hanging
Galvanized steel
support
B
rod by
internal supports
C others
Integral birdscreen
D
Dia.
E
Built-in curb cap
Requires
roof
curb
RJ-4
and RJ-6x9 Dia.
A
D
A
C

RCC-7
Weathertight aluminum
E
B
Integral
birdscreen
A
E
Built-in flashing flange

Throat
Dia.

Model GRSF - Flashing Flange


GRS
GRSF
RJ-4 and RJ-6x9
All aluminum exterior construction
RFC
GRS
D
Galvanized steel internal supports
C
E
Integral
birdscreen
B
B
B
Built-in flashing flange
C
B
C
D
D
C
A
C
Dia.
Dia.
Dia.1.75 (44) D
B
D
A
A
1.75 (44)
Dia.
For
use
A
Throat
Model
with all
A
B
C
A D
Dia.

A
GRS

Model

AFor use

11

RJ-4 and RJ-6x9


GRS
D
D
C
GRSF
RJ-10x10
C
RJ-4 and RJ-6x9
E
B
D
D
C
C
E
B
B
E
C
C
A
D
Dia.
C
D
E
B - Hooded
Model WC (Round Connection)
Model RDC
-BRound Duct
D Connector
A
A
1.75 (44)
Wall CapA
Dia.
Dia. B
B
Replaces the standard square
discharge ductA
A
A
connector
and
damper
Aluminum construction - aluminum finish
Uses existing mounting holes
For outside wall
applications
RCC-7
RFC
GRS
Galvanized steel construction
Built-in birdscreen (not available on WC-4) and
GRSF
RCC-7
B
damper
includes a damper
RFC
B RDC-6
GRS
G
B B
RDC-8 does not include
a damper
B
B
D
F RDC-6
C
C
B
D
Dia.
CB
D
Dia.
C
D
1.5
A C
E
CE
D
Dia. (38)
C
C
D
Dia.
1.75 (44)
A
Dia.
D
A
1.5
(38)
A
A
1.75 (44)
A
Dia.
A
D
E
A
RFC

Wall Discharge Accessories


D

C
1.5

(38)

Model

For use with sizes:

WC-4 C50, B50-B80


1/4-20

WC-6 B90-B200,
A50-A190
hanging
support
rod by
WC-8 A200-A510
others

612

B6
(152)
A

234

(102)

(70)

(127)

(203)

(152)

(165)

8
(203)

1/4-20 11
11
8
hanging
(279)
(203)
support (279)
by (millimeters).
All dimensions shown inrod
inches
others

BModel

(105)

(127)

5 8

3 2

(130)

(89)

A C

C
E

Model

For use with all


sizes:

WL-10x3

50-290

WL-18x6

390-1550

RDC-6

A110-A190

RDC-8

A200-A510

6 (152) 6.25
dia. (159)

A
C

4 (102)
dia.

6.25
(159)

12

514

10

734

312

(305)

(133)

(254)

(197)

(89)

1934

18

(502)

(203)

(457)

(229)

(152)

All dimensions shown in inches (millimeters).

6 (152)
8 (203)

Galvanized steel construction


4 (102)
dia.

Diameter

Reduces duct from 6 to 4 inches.

B 6 (152)
dia.

Model TR 6x4 - Transition Duct Reducer

For use with sizes:

All dimensions shown in inches (millimeters).

6.25

4 (102)

(159)

A C

Not recommended for exterior applications


exposed to severe weather conditions. An
external wall louver is recommended for such
applications.

Model

dia.
WL - Wall Louvered Discharge

6 (152)
Anodized aluminum
grille
dia.
Built-in damper

B418

RDC-8

RDC-6

Model

For use with sizes:


B50-B200

TR 6x4

A50-A90
A110-A190*

All dimensions shown in inches (millimeters).


*Used in conjunction with RDC-6.

12

C
A

25

59)

GRS

GRSF

Wall Discharge Accessories

B
C

D WC - Hooded Wall Cap


Model

Accessory Pressure Drops

Rectangular
Connections)
(44)
1.75
Dia. (Square or
Dia.
A
A Steel construction with black enamel
finish

The chart below can be used with all of the


discharge accessories shown on these two pages.
Specific pressure drop values for these accessories
must be included in total system calculations for
proper fan selection.

For outside wall applications


Built-in birdscreen and damper

30

20

WL-18x6
RJ-10x10

BVE-157,
WC-18x8
BVE-128,
WC-8x8
WC-8
WC-10x3,
WC-6,
RJ-6x9,
EL-10x3,
WL-10x3,
BVE-808,
RFC-7,
RCC-7

10

cfm x 100

C
A
D

9
8
7
6
5
4

Model

For use
with all
sizes:

WC-10x3 50-290
WC-8x8

200-510

WC-18x8 700-1550

512

1234

312

1014 1118

(140)

(324)

(89)

(260)

1014 1014
(260)

(260)
(514)

414

(108)

(127)

814

814

814

634

(210)

(210)

(210)

(171)

(127)

634

(171)

(127)

1014 2014
(260)

(283)

814
(210)

1814 1814
(464)

(464)

All dimensions shown in inches (millimeters).

.01

.02

.03

.04 .05 .06 .07 .08.09.10

.2

.3

.4

.5

.6

Pressure Drop in Inches wg

Above accessories tested with 4 feet of inlet duct

4 (102)
dia.

Model BVE - Brick Vent


Designed for installation in masonry walls
Anodized aluminum construction
Built-in aluminum mesh insect screen

Model

For use
with all
sizes:

BVE808

50-290

BVE128

390-510

BVE157

700-1050

818

734

(206)

(197)

(102)

12

734

(305)

(197)

(102)

1558

734

(397)

(197)

(102)

All dimensions shown in inches


(millimeters).

13

Things to know when


sound is critical
Sound Data
The sound data shown in this catalog has been presented to aid the system designer in selecting a fan which
will meet the desired sound criteria. Sone levels have been included on the performance pages to provide a
means of quickly evaluating the relative loudness of a fan selection.

What is a sone?
Sones are an internationally recognized unit of loudness. In practical terms, the loudness of one sone is
equivalent to the sound of a quiet refrigerator measured from five feet away in an acoustically average room.
A sone is a single number rating, which indicates the inlet noise derived from the eight audible octave bands.
Sones are a linear measurement of sound level. For example, a sound level of 10 sones is twice as loud as
5sones.

What is the difference in an AMCA Sone vs. an HVI Sone?


In general, the AMCA (Air Movement and Control Association) sone value is focused on commercial markets,
whereas the HVI (Home Ventilating Institute) sone value is focused on residential markets. Both calculate their
sone data from the same raw test data (eight octave bands), however an AMCA sone applies a hemispherical
correction factor to the sound power and rounds to the nearest 0.1, whereas HVI applies a spherical correction
factor to the sound power and rounds to the nearest 0.1 under 1.5 sones and to the nearest 0.5 for 1.5 sones
and greater. There are no conversions from one sone to the other, each must be calculated. In every instance,
the same fan will have a lower HVI calculated sone rating than an AMCA calculated sone rating.

Can radiated noise increase the sound levels?


Radiated noise from fan housings can cause unacceptable sound levels, on any brand of fan. The size of
these fans allows them to be placed in areas where this noise will be transmitted to the conditioned space
through walls or ceilings. Where possible, cabinet fans should be located in remote parts of the
ventilation system.

When should a SP or CSP fan be used?


Model SP and CSP fans are designed for the lowest possible sound levels. Forward-curved wheels,
insulated housings and vibration isolators between the motor and housing contribute to quiet, efficient
operation. Applied and installed as recommended, SP and CSP sound levels will fall well within the ranges
shown in the Suggested Limits for Room Loudness chart. For applications where sound levels are critical,
a remote mounted CSP with ductboard is recommended. Placement of SP and CSP fans should take into
account the desired sound level at the location of the listener.
Suggested Limits for Room Loudness
Sones

DBA

1.3-4

32-48 Private homes (rural and suburban)

1.7-5

36-51 Conference rooms

2-6
2.5-8

38-54 Hotel rooms, libraries, movie theatres, executive offices


41-58 Schools and classrooms, hospital wards and operating rooms

3-9

44-60 Court rooms, museums, apartment houses, private homes (urban)

4-2

48-64 Restaurants, lobbies, general open offices, banks

5-15

51-67 Corridors and halls, cocktail lounges, washrooms and toilets

7-21

56-72 Hotel kitchens and laundries, supermarkets

Reprinted from AMCA Publication 302 (Application of Sone Ratings for Non-ducted Air Moving
Devices, with roomsonedBA correlations) with the written permission from the AMCA
International, Inc., 30 West University Drive, Arlington Heights, IL 60004-1893.
NOTE: Values above are for room loudness and are not sound ratings. Room loudness is the resulting
level in a conditioned space after the acoustical qualities of the room have been accounted for.

14

Things to know when


sound is critical
Their compact size allows the system designer greater flexibility in locating these fans for lowest sound
levels. In critical sound areas, insulated ductwork, flexible duct connections, or placing the fan in a remote
section of the ductwork (away from the critical area) offers the best means of meeting desired sound levels.
When room sound levels are critical, such
as in executive offices, conference rooms,
hospital operating rooms, and school study
areas, a CSP fan is the best choice. Shown
here is a comparison of SP and CSP fans
of the same size, with equal performance in
typical installations. The CSP shows lower
sone values.

Model

CFM

WG

FRPM

Sones

SP-A410

405

1/8

1000

3.7

CSP-A410

426

1/8

1000

2.1

*Sone value with insulated inlet duct.

Fiberglass

Remote mounted
model CSP with
vibration isolators
and insulated
ductwork provides
the quietest
installation.

Model SP mounted directly


overhead may be too
loud for sound critical
applications.

Model Number Code


SP - A 50 FL
Light Options:
L - Fan/Light (Incandescent) Combination
FL - Fan/Light (Fluorescent) Combination
Nominal cfm at 0.10 inches static pressure

Level of Construction:
A - Premium unit; lowest sound, insulated housing
B - Deluxe unit; low sound, low profile
C - Standard unit; lowest profile, inexpensive
Model:
SP - Silent Partner
CSP - Cabinet Silent Partner

15

Model SP-A
Premium Ceiling Fan
Model SP-A Dimensions
A

Model
50, 70, 90
110, 125, 190
200, 250, 290,
390
410, 510
700
710, 780
900, 1050,
1410, 1550

1314

1058

1158

(337)

(270)

(295)

(152)

(337)

(270)

(267)

(203) (152)

(356)

(302)

(286)

(203) (203)

(457)

(365)

(368)

(203) (203)

(600)

(295)

(295)

(495) (203)

1314
14
18

2358
18

1058 C 1012
1178

1438
1158

1438

1114

1412
1158

1412

Designer
BGrille

8
8

1912
10

8
8

D
(378 x 337)

(5)

1514 (387) sq.

24
(11)

31

1938 x 1638
(492 x 416)

(14)

(638 x 343)

(15)

2518 x 1312
1938 x 1638

34

(254) (203)

(492 x 416)

(15)

(603)

(365)

(368)

(476) (203)

(635 x 416)

(25)

1834

34

(368)

1412

(8)

(365)

1438

E
C

17

(457)

2334

25 x 1638

Model

RPM

SP-A502, 3, 5

700

SP-A702, 3, 5

Amps

56

0.31

18.3

850

0.27

20.2

SP-A902, 3, 5

900

0.34

29.4

SP-A1102, 3, 4, 5, 6

950

0.58

48.7

SP-A1252, 3, 5, 6

1100

0.62

52.5

SP-A1903, 4, 5, 6

1400

1.30

D
A

A
Watts

113

SP-A2003, 5

900

0.43

48.2

SP-A2503, 5

1000

0.77

83.1

SP-A2903, 4, 5

1050

0.72

80.7

SP-A3903, 4, 5

1350

1.34

135

SP-A4103

1000

1.74

121

SP-A5103, 4

1070

3.30

224

SP-A7003

1100

3.20

350

SP-A7103

1080

4.40

285

SP-A7803, 4

1600

3.30

348

SP-A9003

950

4.00

285

SP-A10503, 4

1095

6.30

420

SP-A14103

1450

7.40

786

SP-A15503, 4

1610

8.60

818

CFM / Static Pressure in E


Inches wg

E
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones

0
76
0.5
83
0.8
99
0.8
119
0.8
135
0.9
216
2.5
247
1.4
272
2.5
315
2.5
410
4.5
443
3.5
557
5.0
757
5.0
752
6.0
812
8.5
955
4.0
1125
6.0
1455
10.0
1607
10.5

2 Available with light


3 Available with CRD - Ceiling Radiation Damper
4 Also available with 50 Hz motors (See page 20 for performance)

0.1
51
0.7
70
0.8
88
1.0
110
0.8
123
1.2
197
2.5
225
2.0
251
2.5
293
2.5
395
4.5
413
3.0
512
4.5
723
5.0
714
6.0
782
8.5
907
5.0
1059
6.0
1415
10.0
1558
10.0

0.125
48
0.8
67
0.8
84
0.9
106
0.1
121
1.3
192
2.5
220
2.0
246
2.5
287
2.5
391
4.5
405
3.0
501
4.5
723
5.0
701
6.0
775
8.5
896
5.0
1043
6.0
1404
10.0
1558
10.0

All dimensions are in inches (millimeters) and weight in pounds (kilograms).


Outlet connection width is 1 in. (25 mm) - Mounting bracket width is 11/2 in. (38 mm).
For complete dimensional information, see CAPS submittal drawings.

12
1478 x 1314

Decorative
Unit
Grille
Weight

0.25
31
C
1.3
42
1.6
F
61
1.2
88
1.1
104
1.3
167
2.5
196
2.5
227
2.5
257
3.0
368
4.5
351
3.0
439
4.5
700
5.5
653
6.0
741
8.0
841
5.0
964
6.0
1353
10.0
1506
10.0

0.375

0.5

0.625

25
1.4

133
2.5
172
3.0
210
3.5
231
3.0
345
5.0
306
3.5
392
4.5
679
5.5
588
6.0
704
8.0
773
5.0
885
5.5
1307
10.0
1449
10.0

D
0.75

0.875

A
D

E
C
142
3.5
185
4.0
207
3.5
325
5.0
325
4.0
649
6.0
486
5.5
665
8.0
701
5.0
796
5.5
1262
10.0
1407
10.5

105
3.5
157
4.0
175
3.5
307
5.5

67
4.0
119
4.0
124
4.5
279
5.5

613
6.0
320
5.5
625
8.0

560
6.5

662
5.5
1218
10.0
1369
11.5

494
6.5

396
6.5

581
8.0

1174
10.0
1323
13.0

5 UL Listed for use above tubs.


6 Available with 277 volt motor.

Performance certified is for model SP exhaust for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft
damper. Speed (rpm) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in spherical fan sones at 5 ft (1.5m)
in a spherical free field calculated per Annex B of AMCA 311. Values shown are for installation type B: free inlet spherical fan sone levels.

16

Model SP-B and SP-C


Deluxe and Standard Ceiling Fan
Model SP-B Dimensions
Model

C*

13 8
(352)

50, 70 & 80

11 2

15

6 16

3/4

(292)

(176)

(102)

(19)

1378

90, 110, 150,


200

(352)

Designer
Grille

1112

71516

(292)

(202)

114
(152) (32)

1478 x 1314
(378 x 337)

Decorative
Unit
Grille
Weight

9
1514 (387) sq.

(4)

10

(5)

All dimensions are in inches (millimeters) and weight in pounds (kilograms). *Add 11/2 in. (38 mm) to C
dimension for incandescent light. Mounting bracket width is 11/2 in. (38 mm). For complete dimensional
information, see CAPS submittal drawings.

Model

RPM

Amps

Watts

SP-B502, 3, 5

625

0.50

37.8

SP-B702, 3, 5

675

0.53

45.1

SP-B802, 3, 5

900

0.60

54.3

SP-B902, 3, 4, 5

700

0.65

49.7

SP-B1102, 3, 4, 5, 6

950

A
1.14

80.2

SP-B1502, 3, 4, 5, 6

1050

1.70

128
E

SP-B2003, 4, 5, 6

1100

2.20

172

CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones

0
67
1.2
77
1.2
87
2.0
101
1.5
133
1.5
160
2.5
197
3.5

0.1
54
1.4
71
1.4
80
2.0
89
2.0
114
1.5
156
2.5
195
4.0

2 Available with light


3 Available with CRD - Ceiling Radiation Damper
4 Also available with 50 Hz motors (See page 20 for performance)

0.125
51
1.4
68
1.4
78
2.5
88
2.0
110
1.5
155
2.5
194
4.0

CFM / Static Pressure in Inches wg


0.25
0.375
0.5
0.625
40
29
2.0
3.0
57
49
39
2.0
2.5
3.0
68
61
54
44
2.5
3.0
3.5
4.5
75
59
45
30
2.5
3.0
3.5
4.0
97
94
91
B 95
A
2.0
2.0
2.0
3.0
154
152
149
147
E
3.0
3.5
3.5
4.0
191
187
184
181
C 4.5
4.5
5.0
5.0
D

0.75

0.875

72
4.0
123
4.5
151
5.5

50
4.5
92
5.0
128
5.5

30
4.5

85
3.5
138
4.5
166
5.5

5 UL Listed for use above tubs.


6 Available with 277 volt motor.

Performance certified is for model SP exhaust for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft
damper. Speed (rpm) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in spherical fan sones at 5 ft (1.5m)
in a spherical free field calculated per Annex B of AMCA 311. Values shown are for installation type B: free inlet spherical fan sone levels.

Model SP-C Dimensions


B

Model
50

712

712

358

(191)

(191)

(92)

(76)

158

(41)E

Decorative Unit
Grille
Weight

1/2

1
9D
4 x 9

(13)

(235 x 229)

(2)

C (millimeters) and weight in pounds (kilograms). For


All dimensions are in inches
complete dimensional information, see CAPS submittal drawings.

A
D

E
C
F

Model
SP-C50

RPM
1680

Amps
0.80

CFM / Static Pressure in Inches wg

Watts
46

CFM
Sones

0
52
3.0

0.1
49
3.0

0.125
49
3.0

0.25
47
3.0

0.375
44
3.5

0.5
38
4.0

0.625
29
4.0

Performance certified is for model SP exhaust for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of
an inlet grille and backdraft damper. Speed (rpm) shown is nominal. Performance is based on actual speed of test. The sound ratings shown
are loudness values in spherical fan sones at 5 ft (1.5m) in a spherical free field calculated per Annex B of AMCA 311. Values shown are for
installation type B: free inlet spherical fan sone levels.

17

Model CSP-A
Premium Inline Fan
Model CSP-A Dimensions
Model
110, 125, 190
200, 250, 290,
390
410, 510

Unit
Weight

1314

1058

1012

12

914

16

(337)

(270)

(267)

(203)

(152)

(305)

(235)

10

23

(356)

(302)

(286)

(203)

(203)

(327)

(254)

(10)

(457)

(365)

(368)

(203)

(203)

(429)

(337)

(16)

(600)

(295)

(295)

(495)

(203)

(575) F (267)

(15)

14
18

2358

700
710, 780
900, 1050,
1410, 1550
1750, 2150
3600

18

1178

1438
1158

1412
1158

1912

8
8

1678

2258

(7)

1314

1012

16 8

13 4

(429)

(337)

(16)

(603)

(365)

(368)

(476)

(203)

G (575)

(337)

(27)

35

14 4
3

1412
14 4
3

(889)

(375)

(375)

(1156)

(419)

(419)

4512

1612

1612

1834
28

(711)

40

8
6

(152)

2258
32 4
3

(832)

11
4314
(1016) (279) (1099)

1314
13

(330)

G
A

59

C
G

68

(31)

1458

122D

(371)

(55)

F
Inlet

D
C

D - diameter
F
Inlet
C

All dimensions are in inches (millimeters) and weight in pounds (kilograms).


B Inlet and outletA
Inlet
connection widths are 1 in. (25 mm) - Mounting bracket width is 11/2 in. (38 mm). For
complete dimensional information, see CAPS submittal drawings.
FxG

E
Model

RPM

Amps

CSP-A110

950

0.62

CSP-A1256

1100

0.63

CSP-A1904, 6

1400

1.10

CSP-A200

900

0.43

CSP-A250

1000

0.79

CSP-A2904

1050

0.71

CSP-A390

1350

1.33

CSP-A410

1000

1.87

CSP-A510

1070

3.11

CSP-A700

1100

3.20

CSP-A710

1080

4.40

CSP-A7804

1600

3.77

CSP-A900

950

4.87

CSP-A10504

1095

6.65

CSP-A1410

1450

7.80

CSP-A15504

1610

8.32

CSP-A1750

1130

6.60

CSP-A2150

1100

7.80

CSP-A3600

1100

7.10

4 Units also available with 50 Hz

Watts

CFM
48.7
Sones
Inlet
CFM
52.5 FxG
Sones
CFM
100.0
Sones
CFM
48.2
Sones
CFM
82.7
Sones
CFM
80.7
Sones
CFM
140.0
Sones
CFM
135.0
Sones
CFM
217.0
Sones
CFM
350.0
Sones
CFM
325.0
Sones
CFM
405.0
Sones
CFM
328.0
Sones
CFM
455.0
Sones
CFM
822.0
Sones
CFM
830.0
Sones
CFM
550.0
Sones
CFM
735.0
Sones
CFM
1330.0
Sones
motors (See page 21

CFM / Static Pressure in Inches wg


0
0.1
0.125
0.25
0.375
0.5
D
B - diameter
A
124
112
110
102
77
0.8
0.7
0.8
91.0
0.9
138
126
124
114
91
1.1
1.1
1.1
1.0
1.2
C
215
202
198
180
159
121
2.0
1.5 E 2.0
2.0
2.5
2.5
254
231
226
203
178
145
0.6
0.4
0.5
0.9
1.0
1.3
266
246
241
221
205
187
B 0.9
1.0 A 1.0
2.0
2.5
3.0
318
299
292
265
248
229
1.1
1.2
1.3
2.0
2.5
3.5
412
400
397
382
363
339
2.0
2.0
2.0
2.5
3.0
4.0
447
441
403
364
317
217
1.5
1.5
1.5
2.0
2.0
2.0
545
514
506
464
405
324
2.5
2.0
2.0
2.0
2.0
2.5
766
755
752
739
726
702
2.0
2.0
2.0
2.0
2.0
2.0
737
698
688
635
567
475
2.5
2.5
2.5
2.5
2.0
2.0
813
784
777
742
707
672
3.0
3.0
3.0
3.0
3.0
2.0
908
852
841
782
715
631
1.4
1.4
1.4
2.0
2.0
3.0
1182
1110
1093
1013
922
832
2.5
2.5
2.5
2.5
2.5
2.5
1584
1543
1533
1483
1439
1395
3.5
3.5
3.5
3.5
3.5
3.5
1672
1618
1604
1543
1484
1427
5.0
4.5
4.5
4.5
4.5
4.0
1842
1768
1749
1619
1464
1284
5.0
5.0
5.0
4.5
4.0
4.0
2249
2175
2156
2044
1900
1701
5.0
4.5
4.5
4.0
4.0
4.0
3778
3653
3622
3460
3280
3091
5.0
5.0
5.0
6.5
4.5
4.0
for performance)
6 Available with 277 volt

0.625

0.75

109
1.5
165
2.5
201
3.0
324
4.5

70
1.5
132
2.5
144
3.0
309
4.5

678
2.0
334
2.0
638
3.0
743
2.5
1345
3.5
1367
4.0
1032
3.5
1424
3.0
2844
4.0
motor.

0.875

635
2.5

549
2.5

418
4.0

603
3.0

567

527

1293
3.5
1307
4.5
772
3.0
1114
3.0
2551
4.0

1238
4.0
1240
4.5
484
3.0

1181
4.0
1172
4.5

2232
3.5

1750
3.5

Performance certified is for model CSP inline for installation type D: Ducted inlet, Ducted outlet. Performance ratings include the effects of a backdraft damper. Speed
(rpm) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in spherical fan sones at 5 ft (1.5m) in a spherical
free field calculated per Annex B of AMCA 311. Values shown are for installation type D: ducted inlet spherical fan sone levels. Ratings do not include the effect of duct
end correction. Ratings are based on 10 ft of insulated duct. The AMCA Certified Ratings Seal applies to air performance ratings only.

18

36

C
E

34

(203)

36

(254)

1438

1278

(368)

10

(365)

14 2

(457)

2334

14 8

1114

Model CSP-B
Deluxe Inline Fan

F
Inlet

Model CSP-B Dimensions


Model
110, 150, 200

15

1 4

10 4

(202)

(152)

(32)

(260)

13 8

11 2 7 16

(352)

(292)

D - diameter
Unit
Weight

G
314 (83)

10 4
1

Inlet
FxG

(5)

All dimensions are in inches (millimeters) and weight in pounds (kilograms).


Outlet connection width is 1 in. (25 mm) - Mounting bracket width is 11/2 in. (38 mm).
For complete dimensional information, see CAPS submittal drawings.

Model

RPM

Amps

CFM / Static Pressure in Inches wg

Watts

CSP-B1104, 6

950

1.14

80

CSP-B1504, 6

1050

1.70

129

CSP-B2004, 6

1100

2.20

173

4 Units also available with 50 Hz motors


(See page 21 for performance)

CFM
Sones
CFM
Sones
CFM
Sones

0
103
1.5
151
2.0
186
3.0

0.1
100
1.5
150
2.0
184
3.0

0.125
100
2.0
149
2.0
189
3.0

0.25
98
2.0
148
2.0
182
3.0

0.375
97
2.0
144
2.5
181
3.5

0.5
96
2.0
146
2.5
179
3.5

0.625
94
2.5
142
3.0
175
3.5

0.75
86
2.5
135
3.0
170
3.5

6 Available with 277 volt motor.

Performance certified is for model CSP inline for installation type D: Ducted inlet, Ducted outlet. Performance ratings include the effects of a backdraft
damper. Speed (rpm) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in spherical fan
sones at 5 ft (1.5m) in a spherical free field calculated per Annex B of AMCA 311. Values shown are for installation type D: ducted inlet spherical fan sone
levels. Ratings do not include the effect of duct end correction. Ratings are based on 10 ft of insulated duct. The AMCA Certified Ratings Seal applies to
air performance ratings only.

19

Model SP
50 Cycle Performance
SP-A

For uses in countries with 50 cycle (50 Hz) power,


Greenheck offers the same reliability and
A performance
B
for ceiling mounted exhaust fans model SP.

Same dimensions and outlet options


Performance shown in 50 cycle CRPMs

E
C

Full line of grille and discharge accessories available

Model SP Dimensions
SP-A
50, 70, 90
110, 125, 190
200, 250, 290,
390
410, 510

710, 780
900, 1050,
1410, 1550

1314

1058

1158

(337)

(270)

(295)

(152)

13 4
1

10 8
5

10 2

(270)

(267)

(203) (152)

(356)

(302)

(286)

(203) (203)

18

(457)

1178

14 8
3

(365)

1114

14 2

(368)

18

1438

1412

(365)

(368)

23 4

(603)

14 8
3

(365)

14 2
1

(368)

14 8 x 13 4
7

(378 x 337)

15 4 (387)
square
1

(203) (203)

10

C (203)
(254)
18 4

(476) (203)

(5)

17
(8)

24

1938 x 16 8

50, 70 & 80
90, 110, 150,
200

13 8

11 2

6 16

15

(352)

(292)

1112

71516

(352)

(292)

(202)

1378

(176)

34

25 x 16 8

56

(635 x 416)

3/4 14 8 x 13 4

(102)

(19)

(25)

(378 x 337)

SP-B

Decorative
Unit
Grille
Weight

114 1478 x 1314


(152) (32) (378 x 337)

(15)

D
E

Outlet connection width is 1 in. (25 mm) - Mounting bracket width is 11/2 in. (38 mm).

SP-B

(492 x 416)

BD

(14)

E3

Designer
Grille

31

(492 x 416)

SP-A (double
wide)
E

(11)

8 B 1938 x 1638 A

(457)
3

A
Decorative
Unit
Grille
Weight
12

(337)

14

Standard
Grille

15 4 (387)
square
1

9
(4)

10
(5)

All dimensions are in inches (millimeters) and weight in pounds (kilograms). *Add 11/2 in. (38 mm) to C
dimension for incandescent light. Mounting bracket width is 11/2 in. (38 mm). For complete dimensional
information, see CAPS submittal drawings.

D
A

C
D
CF

C
Model

RPM

Amps

Watts

SP-A110

950

0.29

49

1400

0.65

113

1050

0.36

81

1350

0.67

135

900

1.65

224

1334

1.65

348

950

3.15

420

1340

4.3

818

700

0.325

50

950

0.57

80

1050

0.85

129

1100

1.1

173

(50 Hertz Motor)

SP-A190
(50 Hertz Motor)

SP-A290
(50 Hertz Motor)

SP-A390
(50 Hertz Motor)

SP-A510
(50 Hertz Motor)

SP-A780
(50 Hertz Motor)

SP-A1050
(50 Hertz Motor)

SP-A1550
(50 Hertz Motor)

SP-B90
(50 Hertz Motor)

SP-B110
(50 Hertz Motor)

SP-B150
(50 Hertz Motor)

SP-B200
(50 Hertz Motor)

Model SP with 50 hertz motor is not AMCA certified.

20

CFM / Static Pressure in Inches of wg.


CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones
CFM
Sones

0.000
119
1.3
216
3.2
329
3.2
410
5.4
447
3.7
677
8.8
990
7.2
1337
11.1
102
1.9
133
2.0
160
3.0
197
4.4

0.050
115
1.3
206
3.0
315
3.3
402
5.4
425
3.5
659
8.9
945
7.0
1314
10.7
97
2.2
124
2.0
158
3.1
196
4.7

0.100
110
1.2
197
2.8
302
3.3
395
5.4
400
3.3
642
8.8
905
6.8
1290
10.6
92
2.6
114
2.1
156
3.3
195
4.6

0.125
106
1.2
192
2.9
296
3.3
392
5.4
388
3.3
633
8.7
886
6.8
1279
10.6
88
2.7
110
2.2
155
3.3
194
4.7

0.150
103
1.3
187
2.9
290
3.4
387
5.5
376
3.3
625
8.6
867
6.8
1266
10.6
86
2.7
107
2.2
155
3.4
194
4.9

0.250
88
1.6
167
3.1
262
3.7
368
5.7
315
3.1
591
8.2
769
6.6
1211
10.5
75
3.0
97
2.4
154
3.7
191
5.1

0.375

133
3.4
222
4.0
345
6.0
159
2.6
544
8.1
531
6.5
1161
11.6
59
3.6
95
2.7
152
4.3
187
5.6

0.500

164
4.9
325
6.3

493
8.1

1112
13.5
45
4.1
94
2.8
149
4.5
184
5.8

Model CSP
50 Cycle Performance
CSP-A

For uses in countries with 50 cycle (50Hz) power,


Greenheck offers the same reliability and performance
for inline cabinet fans model CSP.

Same dimensions and outlet options

B
C

Performance shown in 50 cycle RPMs

Full line of discharge accessories available

CSP-A
110, 125, 190
200, 250, 290,
390
410, 510
700
710, 780
900, 1050,
1410, 1550
1750, 2150
3600
CSP-B
110, 150, 200

Unit
Weight

13 4

10 8

10 2

12

9 4

16

(337)

(270)

(267)

(203)

F6

(305)

(235)

(7)

14

(356)

18

11 8
7

(302)

1438

11 4

(152)

(286)

(203)

(203)

G8

1412

12 8
7

(327)

1678

10

(254)

C36

(365)

(368)

(203)

(203)

(429)

(337)

(16)

(600)

(295)

(295)

(495)

(203)

(575)

D(267)

(15)

18

1158

14 8
3

1158

1912

14 2

10

22
E 58
16 8
7

1012
13 4

(365)

(368)

(254)

(203)
B

(429)

A(337)

(16)

(603)

(365)

(368)

(476)

(203)

(575)

(337)

(27)

(889)

(375)

(375)

(711)

(152)

(832)

(330)

(31)

(1156)

(419)

(419)

(1016)

2334
35

4512

1438
1434

1612

1378

1112

(352)

(292)

1412

1834

1434

28

1612

40

2258
3234

11
4314
(279) (1099)
E

Inlet
715
16
6

FxG (152)
(202)

1314
13

68

1458

122

(371)

(55)

F
Inlet

59

114

1014

314

1014

(32)

(260)

(83)

(5)

CSP-A110
(50 Hertz Motor)

CSP-A190
(50 Hertz Motor)

CSP-A390
(50 Hertz Motor)

CSP-A780
(50 Hertz Motor)

CSP-A1050
(50 Hertz Motor)

CSP-A1550
(50 Hertz Motor)

CSP-B110
(50 Hertz Motor)

CSP-B150
(50 Hertz Motor)

CSP-B200
(50 Hertz Motor)

RPM

Amps
0.31

51

1400

0.55

100

1350
1334

0.665
1.885

144
405

950

3.325

455

1340

4.16

830

950
1050
1100

0.57
0.85
1.1

80
129
173

F
Inlet

D - diameter
C

A
CFM / Static Pressure in Inches of wg

Watts

950

A
E

CSP-B

Model

All dimensions are in inches (millimeters) and weight in pounds (kilograms). Inlet and outlet
C
connection widths are 1 in. (25 mm) - Mounting bracket width is 11/2 in. (38 mm). For
E
complete dimensional information, see CAPS submittal drawings.

D - diameter

Inlet
Unit
D - diameterFxG
Weight

D
B

36

(457)

E
E

Inlet
FxG G

34

(10)

1314

F
Inlet

CSP-AF (double wide)

23

(457)

2358

Model CSP Dimensions

G
D

0.000

0.050

0.100

0.125

0.150

0.250

0.375

CFM

124

116

112

110

109

102

77

Sones

1.1

1.1

1.1

1.1

1.1

1.3

1.3

121

CFM

215

202

198

180

159

Sones

2.3

2.0

2.2

2.7

2.9

3.0

CFM

412

400

397

382

363

339

0.500

324

309
6.5

Sones

2.8

2.7

2.8

3.2

3.7

4.7

5.5

CFM

685

656

648

609

562

520

481

Sones

5.0

4.9

4.8

4.7

4.6

4.7

4.9

CFM

1079

1031

982

957

934

841

655

Sones

6.3

6.3

6.0

5.9

5.9

6.0

5.5

CFM

1391

1326

1311

1240

1171

1098

1019

929

Sones

7.5

7.4

7.4

7.3

7.4

7.3

7.3

7.2

CFM

103

102

100

99

99

98

97

96

0.625

93

Sones

2.0

1.9

2.0

2.1

2.1

2.3

2.6

2.7

3.1

CFM

151

150

149

149

149

148

148

145

142

Sones

2.5

2.7

2.7

2.7

2.7

2.9

3.1

3.4

3.6

CFM

186

185

184

183

183

182

180

178

175

Sones

3.4

3.7

3.6

3.7

3.7

4.0

4.1

4.1

4.3

Model CSP with 50 hertz motor is not AMCA certified.

21

Model SP Specifications
Models SP-A50 thru A1550
Ceiling mounted exhaust fans shall be of the centrifugal direct drive type. The fan housing shall be constructed
of heavy-gauge galvanized steel. The housing interior shall be lined with 1/2 inch (13 mm) acoustical insulation.
The outlet duct collar shall include an aluminum backdraft damper on all SP-A sizes and shall be spring loaded
on size SP-A110 and larger. Outlet shall be adaptable for horizontal or vertical discharge. The designer grille for
sizes SP-A50 through SP-A390 shall be constructed of high-impact polystyrene and for sizes SP-A410 through
SP-A1550, the grille shall be constructed of aluminum. Grilles shall be non-yellowing.
The access for wiring shall be external. The motor disconnect shall be internal and of the plug-in type. The
motor shall be mounted on vibration isolators. The fan wheel shall be of the forward-curved centrifugal
type and dynamically balanced. All fans shall bear the AMCA Certified Ratings program AMCA Sound
and Air Performance seal and shall be UL/cUL Listed. Ceiling or wall mount fans shall be model SP as
manufactured by Greenheck Fan Corporation, Schofield, Wisconsin.
*Model SP-A fans with 50 hertz motors are not AMCA certified.

Models SP-B50, B70, B80, B90, B110, B150, and B200


Ceiling mounted exhaust fans shall be of the centrifugal direct drive type. The fan housing shall be
constructed of galvanized steel. The steel duct collar shall be 4 inch (102 mm) in diameter on the B50, B70,
and B80 and 6 inch (152 mm) in diameter on the B90, B150, and B200 to accept 4 inch (102 mm) and 6 inch
(152 mm) round ductwork and shall include a backdraft damper. The designer grille shall be constructed of
non-yellowing high impact polystyrene and attached to the housing with hidden attachment screws. The
access for wiring shall be external. The motor disconnect shall be internal and of the plugin type.
The motor shall be mounted on vibration isolators. The fan wheel shall be of the forward curved centrifugal
type, constructed of calcium carbonate filled polypropylene and dynamically balanced. All fans shall bear
the AMCA Certified Ratings program AMCA Sound and Air Performance seal and shall be UL/cUL Listed.
Ceiling or wall mount fans shall be model SP-B50, B70, B80, B90, B110, B150 or B200 as manufactured by
Greenheck Fan Corporation, Schofield, Wisconsin.
*Model SP-B fans with 50 hertz motors are not AMCA certified.

Model SP-C50
Ceiling mounted exhaust fans shall be of the centrifugal direct drive type. The fan housing shall be
constructed of galvanized steel. The plastic duct collar shall be a sleeve for ease of connection to
3 inch (76 mm) and 4 inch (102 mm) round ductwork and shall include a backdraft damper. The grille shall be
constructed of non-yellowing high impact polystyrene and attached to the housing with torsion springs.
The wheels shall be constructed of high-strength polymer. The access for wiring shall be easily accessible
internally. The motor disconnect shall be internal and of the plug-in type. All fans shall bear the AMCA
Certified Ratings program AMCA Air Performance seal. Model SP-C50 shall be UL Listed. Fans shall be
model SP-C50 as supplied by Greenheck Fan Corporation, Schofield, Wisconsin.
*Model SP-C fans with 50 hertz motors are not AMCA certified.

22

Model CSP Specifications


Models CSP-A110 thru A3600
Duct mounted exhaust, supply or return air fans shall be of the centrifugal direct drive type. The fan housing
shall be constructed of heavy-gauge galvanized steel. The housing interior shall be lined with 1/2 inch (13
mm) acoustical insulation. The outlet duct collar shall include an aluminum backdraft damper and shall be
adaptable for horizontal or vertical discharge. The access for wiring shall be external. The motor disconnect
shall be internal and of the plug-in type.
The motor shall be mounted on vibration isolators. The fan wheel shall be of the forward-curved
centrifugal type and dynamically balanced. All fans shall bear the AMCA Certified Ratings program AMCA
Air Performance seal and shall be UL/cUL Listed. Ceiling or wall mount fans shall be model CSP as
manufactured by Greenheck Fan Corporation, Schofield, Wisconsin.
*Model CSP-A fans with 50 hertz motors are not AMCA certified.

Models CSP-B110, B150 and B200


Duct mounted exhaust, supply or return air fans shall be of the centrifugal direct drive type. The fan housing
shall be constructed of galvanized steel. The steel duct collar shall be 6 inch (152 mm) in diameter to accept
6 inch (152 mm) round ductwork and shall include a backdraft damper. The access for wiring shall be
external. The motor disconnect shall be internal and of the plug-in type.
The motor shall mounted on vibration isolators. The fan wheel shall be of the forward-curved centrifugal
type, constructed of calcium carbonate filled polypropylene and dynamically balanced. All fans shall bear
the AMCA Certified Ratings program AMCA Air Performance seal and shall be UL/cUL Listed. Ceiling or
wall mount fans shall be model CSP-B110, B150 or B200 as manufactured by Greenheck Fan Corporation,
Schofield, Wisconsin.
*Model CSP-B fans with 50 hertz motors are not AMCA certified.

23

Ceiling Fan Solutions


Ceiling Fans

Ceiling Fans
w/ Light

Ceiling Fans
w/ CRD

Ceiling Fans
w/ Light & CRD

SP-A110

SP-A110

SP-A390

SP-A125

SP-A50

SP-A70

SP-A90

SP-A90

SP-B50

SP-B90

SP-B200

SP-B80

Our Warranty
Greenheck warrants this equipment to be free from defects in material and workmanship for a period
of one year from the shipment date. Any units or parts which prove defective during the warranty
period will be replaced at our option when returned to our factory, transportation prepaid. Motors are
warranted by the motor manufacturer for a period of one year. Should motors furnished by Greenheck
prove defective during this period, they should be returned to the nearest authorized motor service
station. Greenheck will not be responsible for any removal or installation costs.
As a result of our commitment to continuous improvement, Greenheck reserves the right to change

Prepared to Support
Green Building Efforts

specifications without notice.

P.O. Box 410 Schofield, WI 54476-0410 Phone (715) 359-6171 greenheck.com

SP CSP Rev. 7 January 2010