Sei sulla pagina 1di 8

Version: 05

DECO POP

Doc.-No.: 2197

DATA SHEET

SAP-No.: 1681671

Adhemax Accelerator 1

IMDS-No.: not applicable

CONTENTS

1.
2.
3.
4.
5.
6.
7.
8.

Process Information............................................................................................................................... 2
Equipment and Working Parameters..................................................................................................... 2
Make-Up................................................................................................................................................ 3
Maintenance.......................................................................................................................................... 3
Correction Instruction............................................................................................................................. 3
SAP No. for Make-Up and Maintenance Products.................................................................................3
Recommendations for Wastewater Treatment.......................................................................................4
Analytical Instructions............................................................................................................................ 5
Determination of Sulfuric Acid (96 %) by Titration.............................................................................5
Determination of Adhemax Accelerator 1 by Titration..................................................................7

Page: 1 / 8
Released on:

Released by:

05.08.2011

BTT DECO

Version: 05

Adhemax Accelerator 1

Doc.-No.: 2197

1. Process Information
The purpose of the Adhemax Accelerator 1 is to accelerate the Pd-colloids adsorbed on the
ABS or ABS/PC blend materials plastic surface for electroless metallization and to prevent rack metallization
by stripping off the catalyst specifically from the rack isolation.

2. Equipment and Working Parameters


Tanks

Polypropylene, polyethylene, hard PVC, PVC/polyester resin


composite material, equipped with solution agitation by
means of air injection. The tanks must be fitted with an
exhaust.

Exhaust

Required.

pH

Between 0.5 and 1.5

Solution temperature

35 55 C

Treatment time

1 5 min.

Agitation/Air Agitation

Air agitation required.

Filtration

Recommended (PP Filter 5 m)

Page: 2 / 8
Released on:

Released by:

05.08.2011

BTT DECO

Version: 05

Adhemax Accelerator 1

Doc.-No.: 2197

3. Make-Up
Make-Up of 100 l of Adhemax Accelerator 1
DI Water
H2SO4 (conc.)
Adhemax Accelerator 1

Liter

kg

about 97.5
2.25
---

97.5
4.25
6.0

Add 85 l DI Water to the tank.


Carefully add the Sulphuric Acid while continuously stirring.
Dissolve the Accelerator Salt and afterwards fill the tank up with water to the final volume.

4. Maintenance
A new make-up is recommended after a throughput of about 8 12 m/l. It is also recommended to use
10 20 % of an used Accelerator bath if available. If no used bath is available it might be necessary to use a
higher bath temperature after the new make-up.

5. Correction Instruction
Process solution
Adhemax
Accelerator 1

Component
Adhemax
Accelerator 1
Sulfuric Acid

Working Window
50 70 g/l
20 55 g/l

Lack of
component
Rack metallization /
skip plating
Rack metallization /
skip plating

Excess of
component
Skip plating
Skip plating

6. SAP No. for Make-Up and Maintenance Products


PRODUCT

SAP No.

ADHEMAX ACCELERATOR 1

1680343

Page: 3 / 8
Released on:

Released by:

05.08.2011

BTT DECO

Version: 05

Adhemax Accelerator 1

Doc.-No.: 2197

7. Recommendations for Wastewater Treatment


Rinse water and concentrates can be treated by a neutralization precipitation.
Concentrates should be diluted with the rinse water in the ratio of 1 : 3 and then neutralized
with caustic soda/calcium hydroxide to pH 9 10.
For better flocculation add flocculation agent (recommended is polyacryl amide/anionic with a
molecular weight of 4 6 million) and stir. Allow the precipitate to settle for better filtration.

Be sure to observe all local regulations concerning the limit values of pollutants
including the general regulations on dangerous materials!!

Page: 4 / 8
Released on:

Released by:

05.08.2011

BTT DECO

Version: 05

Adhemax Accelerator 1

Doc.-No.: 2197

8. Analytical Instructions
Version: 03

Determination of Sulfuric Acid (96 %) by Titration

Doc.-No.: A0000202-03

Principle:
Acid-base titration.
Reagents required*:

0.1 M sodium hydroxide-standard solution


0.1% methyl orange-indicator solution (0.1 g of methyl orange-indicator dissolved in 100 ml of DI water)

IMPORTANT NOTE: Be sure to observe all local regulations concerning the limiting
values of pollutants including the general regulations on hazardous materials!

Equipment required:

250-ml Erlenmeyer flask


1.0-ml pipette
Usual laboratory equipment

Procedure:

Place 1.0 ml sample** of sample solution into a 250-ml Erlenmeyer flask.


Add 100 ml of DI water.
Add a few drops of methyl orange-indicator solution.
Titrate with 0.1 M NaOH standard solution. Endpoint is obtained when color changes from red to yellow.

Alternative: The Titration can be conducted as a turning point titration


using a titroprocessor equipped with a pH electrode type to determine
the endpoint.

Page: 5 / 8
Released on:

Released by:

05.08.2011

BTT DECO

Version: 05

Adhemax Accelerator 1

Doc.-No.: 2197

The amount of ml 0.1 M Sodium hydroxide-standard solution*** consumed multiplied by 2.78 gives the
content of Sulfuric acid in ml/l.
The amount of ml 0.1 M Sodium hydroxide-standard solution*** consumed multiplied by 4.9 gives the
content of Sulfuric acid in g/l.
Example:
During titration of 1.0 ml of the sample to be tested, 5.5 ml of 0.1 M Sodium hydroxide-standard solution
were used.
Calculation:
5.5 2.78 = 15.13 ml/l Sulfuric acid (96%)
5.5x 4.9 = 26.95 g/l Sulfuric acid

Quality assurance: For maintenance, calibration of measuring devices


and the use of standards and reference materials please refer to the
corresponding guidelines.

*
**
***

Unless otherwise stated, these are always analytical grade substances.


Volumes given exact to a decimal point must be measured with a volumetric pipette.
For the purpose of calculation, the factor of the standard solutions is assumed to be
1.000 and is therefore not taken into account in the examples.

Page: 6 / 8
Released on:

Released by:

05.08.2011

BTT DECO

Version: 05

Adhemax Accelerator 1

Doc.-No.: 2197

Version: 05

Determination of Adhemax Accelerator 1 by Titration

Doc.-No.: EXT-1005-TIT-05

Principle: Redox titration


Reagents required*:

DI-water
0.02 M Potassium permanganate-solution (0.1N)
0.1M sodium thiosulfate solution
2.5 M Sulfuric acid-solution (5 N)
30% Potassium iodide
Starch solution 1 %

Please follow the general regulations for hazardous materials in the Material safety
data sheets!
The analytical procedure is to be followed exactly.
Be sure to observe all local regulations concerning the permitted limits for
pollutants.
Procedure:

5.0 ml** sample is mixed in a 300 ml iodine flask with


20.0 ml** of 0.02 M Potassium permanganate-solution. Afterwards place it closed in the dark for 30 min.
Then add
10 ml 2.5 M sulfuric acid an 5 ml 30% KI and titrate with
0.1 M sodium thiosulfate solution *** until the color changes from brown to bright-yellow. After an
addition of
1 ml of the starch solution, the solution is titrated until the dark blue color in the solution completely
disappeared.
Also prepare a blank solution with 20.0 ml** of 0.02 M Potassium permanganate-solution and 50 ml Di
water in an iodine flask. Afterwards place it closed in the dark for 30 min. Then add
10 ml 2.5 M sulfuric acid and 5 ml 30% KI
Titrate with 0.1 M sodium thiosulfate solution *** until the color changes from brown to bright-yellow.
After an addition of 1 ml of the starch solution, the solution is titrated until the dark blue color in the
solution completely disappeared.

Alternative: The Titration can be conducted as a turning point titration


using a titroprocessor equipped with a platinium electrode to
determine the endpoint.

Page: 7 / 8
Released on:

Released by:

05.08.2011

BTT DECO

Version: 05

Adhemax Accelerator 1

Doc.-No.: 2197

Evaluation:
(ml consumptionblank solution ml consumption sample) 7.40 = Adhemax Accelerator 1 in g/l
Example:
With the blank solution, 20.28 ml, and with a sample, 11.74 ml sodium thiosulfate-volumetric solution*** are
used.
(20.28 11.74) 7.4 = 63.2 g/l Adhemax Accelerator 1

Quality assurance: For maintenance, calibration of measuring devices


and the use of standards and reference materials please refer to the
corresponding guidelines.

*
**
***

Unless otherwise stated, these are always analytical grade substances.


Volumes given exact to a decimal point must be measured with a volumetric pipette.
For the purpose of calculation, the factor of the standard solution is assumed to be 1.000 and is
therefore not taken into account in the examples.

This sheet shall serve for your information. The content of the sheet is based on our best
knowledge. We do not undertake any duty to advise. The contents of the sheet shall not
be considered as an agreement on condition and quality of the goods delivered.
The decision to use our products for its production purposes is the responsibility of our
customer. We can accept liability only for the quality of our products at delivery. If
difficulties arise in the application of our products, we propose that you contact our
technical service department.

Atotech Deutschland GmbH


P.O. Box: 21 07 80
10507 Berlin, Germany
Erasmusstrae 20
10553 Berlin, Germany
phone +49 (0) 30 349 85 0
fax +49 (0) 30 349 85 777

Page: 8 / 8
Released on:

Released by:

05.08.2011