Sei sulla pagina 1di 80

Electromechanical

and solid-state relays


Zelio Relay
Catalogue
April 2009

Reduce the size of your


enclosures and, at the
same time, increase
machine reliability
The new Zelio Relay items
Electromechanical relays RSL
Only 6 mm wide, thus saving considerable space
in your enclosures

6 mm wide

Solid-state relays SSR


Unlimited service life provided by electronic technology
Unlimited service life

Contents
Presentation

Choose compactness with Zelio Relay RSL ....................................................................... 2-3


Choose long life and silent operation with Zelio Relay SSR ................................................. 4-5
Electromechanical and solid-state relays panorama ........................................................... 6-7

Technical characteristics
Zelio
Zelio
Zelio
Zelio

Relay RSL ................................................................................................................................. 8-15


Relay RSB, RXM, RUM, RPM ............................................................................................ 16-49
Relay ABR, ABS .................................................................................................................... 50-69
Relay SSR .............................................................................................................................. 70-77

Make the most of your energy


1

Choose compactness
with Zelio Relay RSL
Only 6 mm
wide, thus reducing the size
of your enclosures

> A solution for


any application

A complete offer
> An offer with maximum flexibility, comprising:
complete products: a single reference for a relay
mounted on a socket,
products for customer assembly: select the relay
and associated socket according to your application.
> Wide choice of sockets available covering a range
of voltages from 12 to 230 V.

An offer that meets the most


demanding standards
Conformity with the European RoHS
(Restriction of Hazardous Substances) directive.
Conformity to international standards
IEC/EN 61810-1, UL508, CSA C22.2 N14, GOST.

100% RoHS
Schneider Electric commits itself to
reducing the environmental impact
of its products
2

> Reliability in any situation


Protection integrated in the socket
The assurance of reliable protection of the relay
irrespective of the supply voltage used.

LED indicator
Power on and relay status LED indicator.

Standard and low level


version relays
For high breaking capacity or low level
current application requirements.

6A

Up to
breaking capacity

> Simplicity of installation


and cabling

Simple maintaining of relay in socket


and its release/removal

Using locking/unlocking lever.

Simplification of cabling

Commoning link available as accessory.

Simple mounting on DIN rail


Choice of 2 connection techniques
Suitable for the majority of your applications.

Screw connector

Spring terminal
3

Choose long life and


silent operation with
Zelio Relay SSR
> Heat exchange guaranteed
The new solid-state relays SSR with SCR (Semiconductor
Controlled Rectifier) outputs offer you two alternatives:

SSRD range

Directly mounted with heat sink to provide heat exchange,


they are easily mounted by clipping directly onto DIN rail and
can also be panel mounted.

SSRP range

Panel mounted, either on their own or combined with


a heat sink for applications requiring considerable heat exchange.

SS

RA
H1

AS
SE
0812 MB
LE
D IN

ME
XIC
O

SSRP relay mounted on heat sink with


thermal interface

4
4

> Distinctive indication


A green LED on the front face of the products provides instant
indication of the relay input status.

> High performance


High breaking capacities

From 10 to 125 A for relays SSRP


From 10 to 45 A for relays SSRD

Wide supply voltage range

Unlimited
service life
due to electronic relay
technology

From 3 to 32 VDC and 90 to 280 VAC

Outputs suited to applications

From 24 to 280 VAC and 48 to 530/660 VAC

Only 22.5 mm and up to 45.5 mm wide

Complete
silence when
switching

Unlimited service life

providing suitability for


building and hospital
applications

Extreme compactness

No preventive maintenance, relays SSR have a


unlimited service life

Silence of electronic technology


Complete silence when switching

Insensitive to vibration

Even in the event of excessive vibration, the relay


will not change state

High switching
frequency
particularly on packaging
and textile machines

> Conformity to

international standards

100%
RoHS

Schneider Electric commits


itself to reducing the environmental
impact of its products

Panorama Zelio Relay


Electromechanical relays

Number CO contacts
Current

1 CO

1 or 2 CO

1 or 2 CO

2, 3 or 4 CO

6A

8-12-16 A

5-12 A

6-10-12 A

Plugs into socket

Mounting
References
Pages

On DIN rail

RSL

RSB

ABR

RXM

8 to 15

16 to 21

50 to 69

22 to 29

Electromechanical relay advantages


Wide choice of number of contacts (up to 4)
Easy installation and maintenance:
Plug-in relay for socket mounting (universal format)
Contact status mechanical indicator and Relay On LED indicator
Lockable Test button for testing relay operation
Electrically separated inputs and outputs, allowing
different voltages

Solid-state relays

2, 3 or 4 CO

1, 2, 3 or 4 CO

1 NO

1 NO

1 NO

10 A

15A

3A

10 ...45 A

10 ...125 A

On DIN rail

On DIN rail

On panel

Plugs into socket


RUM

RPM

ABS

SSRD

SSRP

30 to 39

40 to 49

50 to 69

70 to 77

70 to 77

Solid-state relay (SSR) advantages


Unlimited service life
Wide supply voltage range and high breaking current
(up to 125 A), suited to packaging and textile machines
Relay On LED indicator
Completely silent switching, providing suitability for
building and hospital applications
Insensitive to vibration

Zelio Relay - plug-in relays

Selection guide

RSL slim interface relays

Plug-in relays
PF090211

Application

1
2

Number and type of contacts / conventional thermal


current (Ith on N/O contact)
Control voltage range
Contact type

1260 V

Standard

Yes

Low level

Yes

Type of pins

Flat (PCB type, reinforced)

Operating voltage

Up to a 400 V / c 300 V

Durability
(operating cycles)

Electrical, resistive load

60 000

Mechanical, no-load

10 000 000

Relay type

RSL 1pB4pD

Pages

14
PF090209

1 C/O / 6 A

7
8

Conventional thermal current (Ith)

6A

Connection

Screw connector

LED

Yes

Protection circuit

Yes

Accessories

Socket identification legend

Yes

Bus jumper

Yes

Partition plate

Yes

Socket type

RSL ZVpp

Pages

14
PF090206

9
10

Slim interface relays, pre-assembled

RSL 1PVpp

Pages

14

1
2
3

PF090210

4
5
6

6A
Spring terminals
Yes
Yes

Yes
Yes
Yes

RSL ZRpp

PF090207

14

9
10

RSL 1PRpp
14

Zelio Relay - plug-in relays

Presentation

RSL slim interface relays

Presentation

RSL slim interface relays offer the advantages of compact size and modular design:
their slim width (6 mm) saves space when mounting on a 5 rail at the back of an
enclosure.

RSL relays are available in two versions:


b pre-assembled range: a single reference comprising a relay mounted on its
socket.
v The socket includes a protection circuit (against reverse polarity and surge) and
an LED indicator as standard.
v Two types of connector are available for wire connection: screw connectors or
spring terminals.
v This pre-assembled solution covers a wide range of operating voltages from 12 to
230 V.
b range for customer assembly:
v The relay (standard or low level) and the socket are selected, as required,
according to the operating voltage of the application.
v For maintenance: an RSL slim relay can be replaced without any need to
disconnect the socket wiring.

2
3
1

Description

RSL slim interface relays, pre-assembled


1
2
3
4

6 A relay (standard or low level) with 1 C/O contact.


Lever for retaining, or easy withdrawal of the relay from its socket.
Sockets: wire connection by screw connector or by spring terminals.
All sockets have a built-in protection circuit and LED indicator.

PF090213

PF090208

RSL slim interface relay

1 Five flat, reinforced pins (PCB type).


1
1

2
3

Sockets for RSL slim interface relays


1
2
3
4
5

Five female contacts for the relay pins.


Retaining lever with marker label.
Wire connection by screw connector or by spring terminals.
Protection circuit and LED indicator (built into the socket)
Locating slot for mounting on 5 rail.

10

PF090212

5
Presentation :
page 10

10

Characteristics :
page 11

References :
page 14

Dimensions, schemes :
page 15

Characteristics

Zelio Relay - plug-in relays


RSL slim interface relays

General characteristics

Conforming to standards

IEC 61810-1, UL508, CSA C22-2 No. 14

Product certifications

UL, CSA, GOST

Ambient air temperature


around the device

Vibration resistance
conforming to
IEC/EN 60068-2-6

Storage

- 40 + 85

Operation

- 40 + 55

In operation

10 gn

Not operating

5 gn

Degree of protection

Conforming to IEC/EN 60529

IP 40 (Relays)
IP 20 (Sockets)

Shock resistance
conforming to
IEC/EN 60068-2-27

Opening

10 gn

Closing

5 gn

Protection category

RT III

Mounting position

Any

Insulation characteristics

Rated insulation voltage (Ui)

250 (IEC)

Rated impulse withstand voltage (Uimp)

kV

Dielectric strength
(rms voltage)

Between coil and contact

aV

4000

Between contacts

aV

1000

1
2
3
4
5
6
7
8
9
10

11

Zelio Relay - plug-in relays

Characteristics (continued)

RSL slim interface relays

Contact characteristics

1
2
3

Relay type

RSL1ABppp

RSL1GBppp

Number and type of contacts

1 C/O

1 C/O low level

Contact materials

AgSnO2

AgSnO2 - gold plated

N/C

N/O

Conventional thermal
current (Ith)

For ambient
temperature y 55 C

Rated operational current


in utilisation categories
AC-1 and DC-1

Conforming to IEC
Conforming to UL

Switching current

Minimum

mA

100

1 (at 50 mW)

Switching voltage

Rated

aV

250

250

Maximum

a 400, c 300

a 250, c 300

Minimum

12

1 (at 50 mW)

6 / a 250V, 0.5 mm

VA

1500

18150 (depending on the voltage)

mW

120

Nominal load (resistive)


Switching capacity

4
5

Maximum

a
c

Minimum

50

Maximum operating rate


In operating cycles

No-load

72000

Under load

360

Mechanical durability

In millions of operating cycles

10

Electrical durability
Resistive load
In millions of operating cycles
Inductive load

See curves below


0.05 (N/O contact /250 V, 3 A, AC-15)
Maximum switching capacity on c load

200
100

Resistive load
a 250V

AgSnO2

Resistive load
105

20

10
0,1 0,2

Coil characteristics

107

106

50
40
30

Electrical durability
Cycles

Voltage c

300

Average consumption

Drop-out voltage threshold

Operating time
(response time)

10 20
Current c

104

4
5
6
3
Switching current (A)

0.17
u 0.05 Uc

ms

12 max

Between coil de-energisation and


making of the Off-delay contact

ms

5 max

12

24

48

60

JD

BD

ED

ND

848

3390

10 600

20 500

Min.

8.4

16.8

33.6

42

Max.

16.8

33.6

67.2

84

Average resistance at 23 C 10%


Operating voltage limits

10

12

Relay control voltage codes

Presentation :
page 10

Between coil energisation and


making of the On-delay contact

Control circuit voltage Uc


DC supply

0,5

Characteristics :
page 11

References :
page 14

Dimensions, schemes :
page 15

Characteristics (continued)

Zelio Relay - plug-in relays


RSL slim interface relays

Socket characteristics
Socket type

RSL ZVpp

RSL ZRpp

Relay types used

RSL 1pppp

RSL 1pppp

Conforming to standards

IEC 61984, UL508, CSA C22-2 No. 14

Product certifications

UL, CSA, GOST

Contact terminal arrangement

Separate

Separate

Wire connection method

Screw connector

Spring terminals

mm

6.2

6.2

Conventional thermal current (Ith)

Maximum operating voltage

300

Between adjacent output contacts

Vrms

2500

Between input and output contacts

Vrms

2500

Between contacts and 5 rail

Vrms

2500

- 40+ 70 / - 40+ 55 for U > 80 V

Width

1
2

Electrical characteristics

Insulation characteristics

General characteristics
Ambient air temperature
around the device

Operation

Storage

Degree of protection

Conforming to IEC/EN 60529

Cabling

Solid cable
1 conductor
without cable end

mm

0.22.5

0.21.5

AWG

2414

2416

Flexible cable
with cable end

mm

0.22.5

0.21.5

AWG

24 14

2416

Screw size

mm

M 2.5

Maximum tightening torque

Nm

0.5

1 conductor

- 40+ 85

IP 20

10 N40 N (0.2 1.5 mm)

Mounting

On 35 mm 5 rail

Fixing on 5 rail

By plastic compression spring

Terminal referencing

IEC

LED indicator

Yes (built-in)

Protection circuit

Yes (built-in)

Wire connection method

Screw connector

6
Spring terminal

7
Sockets operating voltage

Operating voltage

Tolerance

V
Socket type

RSLZVA1, RSLZRA1

Control circuit voltage (relay)


V

c/a 12

+ 20% / - 5%

c 12

c/a 24

+ 20% / - 10%

c 24

c/a 48

+ 20% / - 10%

c 48

c/a 60

+ 20% / - 10%

c 60

RSLZVA3, RSLZRA3

c/a 110

+ 15% / - 20%

c 60

RSLZVA4, RSLZRA4

c/a 230

+ 15% / - 20%

c 60

RSLZVA2, RSLZRA2

8
9
10

13

Zelio Relay - plug-in relays

References

RSL slim interface relays

Slim interface relays, pre-assembled


PF090207

Relays mounted on socket equipped with LED and protection circuit


PF090206

Sold in lots of 10

1 C/O contact - Thermal current (Ith) 6A


Operating voltage

Control circuit voltage

Socket type
Screw connector
Unit reference

2
RSL1PVpp

RSL1PRpp

Spring terminal
Weight

Unit reference

kg

Weight
kg

c/a 12

c 12

RSL1PVJU

0.031

RSL1PRJU

0.029

c/a 24

c 24

RSL1PVBU

0.031

RSL1PRBU

0.029

c/a 48

c 48

RSL1PVEU

0.031

RSL 1PREU

0.029

c/a 110

c 60

RSL1PVFU

0.031

RSL1PRFU

0.029

c/a 230

c 60

RSL1PVPU

0.031

RSL1PRPU

0.029

Slim interface relays for customer assembly: relay + socket


Relays with flat, reinforced pins (PCB type)
PF090211

Sold in lots of 10

1 C/O contact - Thermal current (Ith) 6A


Standard
Control circuit voltage

Unit reference

V
RSL1pppp

Low level
Weight

Unit reference

kg

Weight
kg

c 12

RSL1AB4JD

0.006

RSL1GB4JD

0.006

c 24

RSL1AB4BD

0.006

RSL1GB4BD

0.006

c 48

RSL1AB4ED

0.006

RSL1GB4ED

0.006

c 60

RSL1AB4ND

0.006

RSL1GB4ND

0.006

PF090209

PF090210

Sockets equipped with LED and protection circuit


Sold in lots of 10

Socket type
Screw connector
Operating voltage

For use with relays

Unit reference

7
RSLZVAp

Spring terminal
Weight

Unit reference

kg

Weight
kg

c/a 12 and c/a 24

RSL1pB4JD
RSL1pB4BD

RSLZVA1

0.025

RSLZRA1

0.023

c/a 48 and c/a 60

RSL1pB4ED
RSL1pB4ND

RSLZVA2

0.025

RSLZRA2

0.023

c/a 110

RSL1pB4ND

RSLZVA3

0.025

RSLZRA3

0.023

c/a 230

RSL1pB4ND

RSLZVA4

0.025

RSLZRA4

0.023

RSLZRAp

Accessories for sockets


Sold in lots of 10
RSLZ2

9
10

Description

Compatibility

Unit reference

Clip-in legends
(sheet of 64 legends)

With all sockets

RSLZ5

0.001

Bus jumper
(20-pole jumper)

With all sockets

RSLZ2

0.003

Partition plate

With all sockets

RSLZ3

0.001

Characteristics :
page 11

References :
page 14

RSLZ3

Presentation :
page 10

14

Dimensions, schemes :
page 15

Weight
kg

Zelio Relay - plug-in relays

Dimensions,
schemes

RSL slim interface relays

Slim interface relays, pre-assembled

RSL1PRpp (spring terminals)

51,5

6,2

101

95

35,3

30,1

RSL1PVpp (screw connector)

6,2

51,5

78,6

6,2

6,2

78,6

Relays for customer assembly

RSL1pppp with flat, reinforced pins (PCB type)

3,50,5

11,34 (1) (1) 1,9

5 max

1 C/O contact

14

28 max

11
12
A1

3,78

15 max

A2

(1): 5.04 mm

Sockets equipped with LED and protection circuit

RSLZRpp (spring terminals)


35,3

30,1

RSLZVpp (screw connector)

101

95

6
7

51,5

6,2

6,2

51,5

78,6

6,2

6,2

78,6

Socket connections

Example of RSLZ2 bus jumper


mounting on sockets

RSLZVpp (screw connector)

RSLZRpp (spring terminals)

12

12

11

11

14

Side view

(1)

14

(3)

(2)
A1
A2

Protection
circuit

14

A1

11

A2

12

Protection
circuit

14

(4)

11
12

A1

A1

A2

A2

10
(1) A1
(2) A2
(3) Bus jumper polarity A1
(4) Bus jumper polarity A2

15

Zelio Relay - plug-in relays

Selection guide

Application

Plug-in relays
Interface relays

Miniature relays

2
3

Number and type of contacts / conventional thermal


current (Ith on N/O contact)

1 C/O / 16 A
1 C/O / 12 A
2 C/O / 8 A

2 C/O / 12 A
3 C/O / 10 A
4 C/O / 6 A
4 C/O / 3 A (low level)

24240 V
6110 V

24240 V
12220 V

Type of pins

Flat (Faston type)

Flat (Faston type)

Operational voltage

Up to a 400 V / c 300 V

Up to 250 V

Control circuit voltage

4
5
6

a
c

Durability
(operating cycles)

Electrical, resistive load


Mechanical, no-load

100 000
30 000 000

100 000
10 000 000

Functions

LED
Mechanical indicator
Lockable test button
Low level contacts

Yes (with protection modules)

Yes (depending on version)


Yes
Yes
Yes (depending on version)

Type reference

RSB

RXM

Pages

20

25 and 26

Conventional thermal current (Ith)

12A (1)

10 A

12 A (2)

Contact terminal arrangements

Separate

Mixed

Separate

Connection

Connector

Screw clamp terminals or


connector

Connector

Accessories Protection modules


Timer module
Maintaining clamps
Socket identification legend

Yes

Yes
Yes

Yes

Yes
Yes (except RXZ E2M114)
Yes
Yes

Yes

RSZ E1SppM

RXZ E2Mppp

7
8
9

Mounting adapters for 5 rail


Mounting adapters with fixing lugs
Bus jumper, 2-pole (Ith = 5 A)

10

Associated socket types

Pages

16

RXZ E2Sppp

20
26
26
(1) When using relay RSB1A160pp with socket RSZE1S48M, terminals must be linked.
(2) Except for sockets RXZ E2S11pM: 10 A.

Universal relays

Power relays

1
2

2 C/O / 10 A
3 C/O / 10 A
3 C/O / 3 A (low level)

2 C/O / 10 A
3 C/O / 10 A

1 C/O / 15 A
2 C/O / 15 A
3 C/O / 15 A
4 C/O / 15 A

24230 V
12220 V

12110 V

24230 V
12110 V

Cylindrical

Flat (Faston type)

Flat (Faston type)

Up to 250 V

Up to 250 V

100 000
5 000 000

100 000 (3)


10 000 000

Yes (depending on version)


Yes
Yes
Yes (depending on version)

Yes (depending on version)


Yes
Yes

RUM

RPM

33

43

3
4
5
6
7

12 A
Mixed

16 A
Separate

Connector

Screw clamp terminals

Yes
Yes
Yes
Yes

Yes

Yes
Yes (for 3 and 4-pole)
Yes (on socket RPZ F1)
Yes
Yes
Yes

RUZ CpM

RUZ SCpM

34
(3) 100 000 for RPM1 and RPM2; 60 000 for RPM3 and RPM4.

Mixed

RUZ SF3M

RPZ Fp

34

44

9
10

17

Zelio Relay - plug-in relays

Presentation,
characteristics

523139

Presentation of the range


The RSB interface relay range comprises:
1 12 A relays with 1 C/O contact , 16 A relays with 1 C/O contact and 8 A relays with
2 C/O contacts.
2 Sockets with separate contact terminals.
3 Protection modules (diode, diode + LED, RC circuit or varistor + LED). All these
modules are common to all sockets.
4 A plastic maintaining clamp for all sockets.
5 Clip-in legends for the sockets.

Socket description
Sockets with separate contact terminals (1)
1 Connection by connector.
2 Five or eight female contacts for the relay pins.
3 A fixing hole for panel mounting.
4 Location for protection modules.
5 Locking components for plastic maintaining clamp.
6 Locating slot for mounting on 5 rail.

535188

RSB interface relays

Inputs

Outputs

2
5
3

(1) The inputs and outputs are separated from the relay supply.

Relay supply

General characteristics

6
7
8
9

Conforming to standards
Product certifications
Ambient air temperature
around the device

Storage
Operation
Vibration resistance
Conforming to IEC/EN 60068-2-6
Degree of protection
Conforming to IEC/EN 60529
Shock resistance
Opening
conforming to IEC/EN 60068-2-27 Closing
Protection category
Mounting position

Insulation characteristics
Rated insulation voltage (Ui) Conforming to IEC/EN 60947
Rated impulse withstand voltage (Uimp)
Dielectric strength
Between coil and contact
(rms voltage)
Between poles
Between contacts

V
kV
aV
aV
aV

400
3.6 (1.2/50 s)
5000
2500
1000
RSB1A160pp
1 C/O

RSB2A080pp
2 C/O

RSB 1A120pp
1 C/O
AgNi
12

16

A
A

12
6

16
8

8
4

mA
V
V
A
A
VA
W
mW

5
a 400, c 300
5
12 / 250a V
12 / 28c V
3000
336
300
72 000
600

16 / 250a V
16 / 28c V
4000
448

8 / 250a V
8 / 28c V
2000
224

Contact characteristics
Relay type
Number and type of contacts
Contact materials
Conventional thermal
current (Ith)
Rated operational current
in utilisation categories
AC-1 and DC-1
Switching current
Switching voltage

For ambient
temperature y 40C
Conforming to IEC

C
O

Minimum
Maximum
Minimum

Nominal load (resistive)

10

C
C

IEC/EN 61810-1, UL 508, CSA C22-2 n 14


UL, CSA
- 40+ 85
c - 40+ 85, a - 40...+ 70
>10gn (10..150 Hz)
IP 40
5 gn
10 gn
RT I
Any

Switching capacity

Maximum

Maximum operating rate


In operating cycles/hour

Minimum
No-load
Under load

Presentation:
page 18

References:
page 20

18

a
c

Characteristics:
page 19

Dimensions, schemes:
page 21

Zelio Relay - plug-in relays

Characteristics

RSB interface relays

Relay type
Mechanical durability
Electrical durability
In millions of op. cycles

107

A
106

C
B

105

RSB 1A120pp
RSB1A160pp
RSB2A080pp
u 30
12 A - 250 V: u 0.1
16 A - 250 V: u 0.07
8 A - 250 V: u 0.1
See curves below
Reduction coefficient for inductive load a
Maximum switching capacity on resistive load
(depending on power factor cos j)
c
Reduction coefficient (A)

Durability (Number of operating cycles)

In millions of operating cycles


Resistive load
Inductive load
Electrical durability of contacts
Resistive load a

1
0,

Current c

Contact characteristics (continued)

0,6
0,5

50

16
12

5

2
1

0,4

0,5

104

0,3
0

0,4

0,8 1 1,2

1,6

0,1

0,6

0,4

10

0,2

20 30

50

100

200 300

Voltage c

Switching capacity (kVA)

A RSB2A080pp B RSB1A160pp C RSB1A120pp. Durability (inductive load) = durability (resistive load) x reduction coefficient.
Coil characteristics

Average consumption
Drop-out voltage threshold
Operating time
Between coil energisation and
(response time)
making of the On-delay contact

a
c
Between coil de-energisation and a
making of the Off-delay contact
c
Control circuit voltage Uc
Relay control voltage codes
d.c. supply
Average resistance at 20 C 10%
Operating
Min.
voltage limits
Max.
Relay control voltage codes
a.c. supply
Average resistance at 20 C 15%
60 Hz
Operating
Min.
50 Hz
voltage limits
60 Hz
Max.
50/60Hz

Socket characteristics

ms
ms
ms
ms
V
W
V
V
W
V
V

Socket type
Relay types used
Contact terminal arrangement
Wire connection method
Product certifications
Conforming to standards

Electrical characteristics

c 0.45 W, a 0.75 VA
c 0.1 Uc, a 0.15 Uc
12
9
10
4
6
12
24
RD
JD
BD
90
360
1440
4.8
9.6
19.2
6.6
13.2
26.4

B7

400

19.2

20.4

26.4

4
48
ED
5700
38.4
52.8
E7
1550
38.4
40.8
57.6

60
ND
7500
48
66

RSZ E1S35M
RSB 1A120pp
Separate
Connector
e
IEC 61984, UL, CSA

Conventional thermal current (Ith)


Maximum operating voltage

A
V

12
300

Between adjacent output contacts


Between input and output contacts
Between contacts and 5 rail

Vrms
Vrms
Vrms

2500
2500
2500

Ambient air temperature


around the device
Degree of protection
Cabling
screw connector

C
C

- 25+ 85
- 40+ 85
IP 20
0.52.5 mm2 - AWG 20AWG 14
0.51.5 mm2 - AWG 20AWG 16
0.252.5 mm2 - AWG 22AWG 14
0.251 mm2 - AWG 22AWG 17
0.8 / M3 screw
On 35 mm 5 rail / on panel
By plastic compression spring
IEC
No
Yes, plastic
No
All RZM ppp
Yes

Insulation characteristics

General characteristics

Operation
Storage
Conforming to IEC/EN 60529
Solid cable
1 conductor
without cable end 2 conductors
Flexible cable
1 conductor
with cable end 2 conductors
Maximum tightening torque / Screw size
Mounting
Fixing on 5 rail
Terminal referencing
Bus jumper (Ith: 5 A)
Compatibility with the metal maintaining clamp
Timer module
Protection module
Clip-in legends
Wire connection method
Screw connector

Nm

110
FD
25 200
88
121

120

F7
10 200
96
102
144

220

M7
35 500
176
187
264

230

P7
38 500
184
195.5
276

240

U7
42 500
192
204
288

RSZ E1S48M
RSB2A080pp, RSB1A160pp (1)

5
6
7
8
9
10

(1) When using the relay with socket RSZ E1S48M, terminals must be linked. See connection schemes on page 21.

19

Zelio Relay - plug-in relays

References

560583

Relays for standard applications


Control
circuit
voltage

1
2
RSB 1A120JD + RZM 031FPD
+ RSZ E1S35M

560584

3
4
5

Sold in
lots of

Number and type of contacts - Thermal current (Ith)


1 C/O - 12 A
1 C/O - 16 A
2 C/O - 8 A
Unit
Unit
Unit
reference (1)
reference (1)
reference (1)

Weight

V
c6

10

RSB1A120RD

RSB1A160RD

RSB2A080RD

kg
0.014

c 12

10

RSB1A120JD

RSB1A160JD

RSB2A080JD

0.014

c 24

10

RSB1A120BD

RSB1A160BD

RSB2A080BD

0.014

c 48

10

RSB1A120ED

RSB1A160ED

RSB2A080ED

0.014

c 60

10

RSB1A120ND

RSB1A160ND

RSB2A080ND

0.014

c 110

10

RSB1A120FD

RSB1A160FD

RSB2A080FD

0.014

a 24

10

RSB1A120B7

RSB1A160B7

RSB2A080B7

0.014

a 48

10

RSB1A120E7

RSB1A160E7

RSB2A080E7

0.014

a 120

10

RSB1A120F7

RSB1A160F7

RSB2A080F7

0.014

a 220

10

RSB1A120M7

RSB1A160M7

RSB2A080M7

0.014

a 230

10

RSB1A120P7

RSB1A160P7

RSB2A080P7

0.014

a 240

10

RSB1A120U7

RSB1A160U7

RSB2A080U7

0.014

Connection

Relay type

Connector

RSB 1A120pp
RSB 1A160pp (2)
RSB2A080pp

Sold in
lots of
10
10

Unit
reference
RSZ E1S35M
RSZ E1S48M

Weight
kg
0.060
0.050

For
use with

Voltage

Sold in
lots of

Unit
reference

Weight

V
c 6230

10

RZM040W

kg
0.003

Sockets 12 A, a 300 V
RSB 1A160BD + RSZ E1S48M

Description

7
8

Contact terminal
arrangement
Separate

Protection modules

560582

RSB interface relays

Diode

All sockets

RC circuit

All sockets

a 2460
a 110240

10
10

RZM041BN7
RZM041FU7

0.010
0.010

Diode + green LED

All sockets

c 624
c 2460
c 110230

10
10
10

RZM031RB
RZM031BN
RZM031FPD

0.004
0.004
0.004

Varistor + green LED

All sockets

c or a 624
c or a 2460
c or a 110230

10
10
10

RZM021RB
RZM021BN
RZM021FP

0.005
0.005
0.005

Sold in
lots of
10
10

Unit
reference
RSZR215
RSZ L300

RSB 2A080BD + RSZ E1S48M

Accessories
560585

Description
Plastic maintaining clamp
Legend

For
use with
All sockets
All sockets

Weight
kg
0.002
0.001

(1) To order a relay complete with socket (sold in lots of 20): add suffix S to one of the following voltage codes JD, BD, B7, P7 or F7.
Example: RSB2A080BD +RSZE1S48M becomes RSB2A080RBS.
(2) When using the relay with socket RSZ E1S48M, terminals must be linked. See connection schemes on page 21.
RSZ R215

10
Presentation:
page 18

20

References:
page 20

Characteristics:
page 19

Dimensions, schemes:
page 21

Zelio Relay - plug-in relays

Dimensions,
schemes

RSB interface relays

Dimensions

Interface relays
RSB 1A120pp

RSB2A080pp, RSB1A160pp

12,5
7,5

12,5
7,5

29

2,5

15

16,5

29

15,7
3,9

2,5

3,5

3,5

15,7
3,9

Sockets
RSZ E1S35M

RSZ E1S48M

67
61

67
61

(4)

(4)

11

21

11

14

24

14

12

22

12

(1)
78,5

78,5

(1)

(3)

29,4

(2)
A2

(2)
A2

A1

15,5

27,5
34,5

29,4

(3)

A1

15,5

27,5
34,5

50

50
(1) Relays
(2) Protection module
(3) Maintaining clamp
(4) Legend

Schemes

Interface relays

14

21

11

22

12

A2

A1

A2

A1

12

24

A2
A1

22

24

14

21

11

22

12

A1

11

21

11

14

12

A2

24

8
9

A2

14

RSB2A080pp

A1

14/24

12/22

A2
A1

RSB1A160pp

11/21

14

12

11

RSB 1A120pp

When using relay RSB1A160pp with socket RSZ E1S48M


terminals 11 and 21, 14 and 24, 12 and 22 must be linked

Protection modules
RZM 040W

RZM 041ppp

RZM 031ppp

10

RZM 021ppp

A2

A2

A2

A2

+ A1

+ A1

+ A1

+ A1

21

Zelio Relay - plug-in relays

Presentation

Presentation of the range

524766

RXM miniature relays

The RXM miniature relay range comprises:


1 12 A relays with 2 C/O contacts, 10 A relays with 3 C/O contacts, 6 A relays with
4C/O contacts and 3 A low level relays with 4 C/O contacts. All these relays
have the same dimensions.
2 Sockets with mixed or separate contact terminals.
3 Protection modules (diode, RC circuit or varistor). All these modules are common
to all sockets.
4 A metal maintaining clamp for all sockets.
5 A plastic maintaining clamp for all sockets.
6 A 2-pole bus jumper that can be used on sockets with separate contact terminals
in order to simplify cabling when creating an equipotential link between the coil
terminals.
7 Clip-in legends for all the sockets except RXZ E2M114.

4
or
5
6

106557

8
1
2
3

106661

106660

10

Socket description

6
1

106014

106662

7 6

Relay description

1 Spring return pushbutton for testing the contacts (green: c, red: a).
2 Mechanical relay status indicator.
3 Removable lock-down door enabling forced maintaining of the contacts for test
sequences or maintenance purposes. During operation, this lock-down door must
always be in the closed position.
4 LED (depending on version) indicating the relay status.
5 Removable legend for relay identification.
6 Four notches for rail mounting adapter or panel mounting adapter with fixing lugs.
7 Eight, eleven or fourteen Faston type pins.
8 Area by which the product can be easily gripped.
9 Mounting adapter enabling direct mounting of the relay on a panel.
10 Mounting adapter enabling direct mounting of the relay on a 5 rail.

Outputs

Sockets with mixed contact terminals (1)


1 Connection by screw clamp terminals or screw connector.
2 Fourteen female contacts for the relay pins.
3 Location for protection modules.
4 Locking components for plastic and metal maintaining clamps.
5 Locating slot for mounting on 5 rail with its compression spring or fixing clip.
6 Two or four fixing holes for panel mounting.

4
3
Inputs

Relay supply

6
106015

1
Inputs

Outputs

2
4

Sockets with separate contact terminals (2)


1 Connection by screw connector.
2 Eight, eleven or fourteen female contacts for the relay pins.
3 Location for protection modules.
4 Locking components for plastic and metal maintaining clamps.
5 Locating slot for mounting on 5 rail with its compression spring or fixing clip.
6 Two fixing holes for panel mounting.
7 Location for bus jumpers (see mounting on sockets on page28).

3
(1) The inputs are mixed with the relay's supply, with the outputs being located on the opposite
side of the socket.
(2) The inputs and outputs are separated from the relay supply.

10
5 7

Presentation :
page 22

22

Relay supply
Characteristics :
pages 23 and 24

References :
pages 25 and 26

Dimensions :
pages 27 and 28

Schemes :
page 29

Zelio Relay - plug-in relays

Characteristics

RXM miniature relays

General characteristics
Conforming to standards
Product certifications
Ambient air temperature
around the device

Storage
Operation
Vibration resistance
In operation
conforming to IEC/EN 60068-2-6 Not operating
Degree of protection
Conforming to IEC/EN 60529
Shock resistance
Opening
conforming to IEC/EN 60068-2-27 Closing
Protection category
Mounting position

IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n 14


UL, CSA
- 40 + 85
- 40 + 55
3gn (10...150Hz/ 1 mm / 5g/5 cycles)
5gn (10...150Hz/ 1 mm / 5g/5 cycles)
IP 40
15 gn
15 gn
RT I
Any

C
C

1
2

Insulation characteristics
Rated insulation voltage (Ui)
Rated impulse withstand voltage (Uimp)
Dielectric strength
Between coil and contact
(rms voltage)
Between poles
Between contacts

V
kV
aV
aV
aV

250 (IEC), 300 (UL, CSA)


4 (1.2/50 ms)
1550
1550
1500

RXM3ABppp
3 C/O

RXM4ABppp
4 C/O

RXM2ABppp
2 C/O
AgNi
12

10

10
5
10

6
3
6

10 / 250a V
10 / 28c V
2500
280

6 / 250a V
6 / 28c V
1500
168

Contact characteristics
Relay type
Number and type of contacts
Contact materials
Conventional thermal
current (Ith)
Rated operational current
in utilisation categories
AC-1 and DC-1

For ambient
temperature y 55 C
Conforming to IEC
"C"
O
Conforming to UL
Minimum
Maximum
Minimum

Switching capacity

Maximum

Maximum operating rate


In operating cycles

Minimum
No-load
Under load

Utilisation coefficient
Mechanical durability

In millions of operating cycles

12
6
12
10
a/c 250 (IEC)
17
12 / 250a V
12 / 28c V
3000
336
170
18 000
1200
20 %
10

Electrical durability
In millions of operating cycles

Resistive load
Inductive load

0.1
See curves below

Nominal load (resistive)


a
c

107

106

D
C

105
0

A RXM2ABppp

1
0,
0,6
0,5

B RXM3ABppp

0,4

0,3

C RXM4ABppp

5
3 / 250a V
3 / 28c V
750
84
15

10
6

A
D

Maximum switching capacity on resistive load


c

1
2
Switching capacity (kVA)

2
1
3
3

0,1

0,6

0,4

Reduction coefficient for inductive load a


(depending on power factor cos j)
Reduction coefficient (A)

Durability (Number of operating cycles)

Electrical durability of contacts


Resistive load a

mA
V
V
A
A
VA
W
mW

Current c

Switching current
Switching voltage

RXM4GBppp
4 C/O low level
AgAu - bifurcated
3

0,2

28 50

100

150

200
250
Voltage c

D RXM4GBppp

Durability (inductive load) = durability (resistive load) x reduction coefficient.

10

23

Zelio Relay - plug-in relays

Characteristics (continued)

Coil characteristics

RXM miniature relays

Average consumption

Drop-out voltage threshold

Operating time
(response time)

Between coil energisation


and making of the
On-delay contact

Between coil de-energisation


and making of the
Off-delay contact

VA

1.2

0.9
u 0.15 Uc

c
c

Control circuit voltage Uc

u 0.1 Uc
ms

20

ms

20

ms

20

ms

20

12

24

48

110

120

125

220

230

240

JD

BD

ED

FD

GD

MD

Relay control voltage codes


d.c. supply

Average resistance at 20 C 10%

160

650

2600

11 000

11 000

14 000

Operating voltage limits

Min.

9.6

19.2

38.4

88

100

176

Max.

13.2

26.4

52.8

121

138

242

B7

E7

F7

P7

U7

Relay control voltage codes


a.c. supply

Average resistance at 20 C 15%

180

770

4430

15 000

15 500

Operating voltage limits

Min.

19.2

38.4

96

184

192

Max.

26.4

52.8

132

253

264

Socket characteristics

4
5

Socket type

RXZE2S108M RXZE2S111M RXZE2S114M RXZE2M114M

RXZE2M114

Relay types used

RXM 2ppppp

RXM2ppppp (1)
RXM 4ppppp

Contact terminal arrangement


Wire connection method

Separate
Connector

Product certifications
Conforming to standards

UL, CSA
IEC 61984, e

Electrical characteristics

7
8
9
10

RXM 4ppppp

Screw clamp
terminals

A
V

12
250 (IEC)

Between adjacent output contacts


Between input and output contacts
Between contacts and 5 rail

Vrms
Vrms
Vrms

2500
2500
2500

Ambient air temperature


around the device

C
C

- 40+ 55
- 40+ 85
IP 20
0.52.5 mm2 - AWG 20AWG 14

General characteristics

Operation
Storage
Degree of protection
Conforming to IEC/EN 60529
Cabling
Solid cable
1 conductor
without
cable end
2 conductors
Flexible cable 1 conductor
with cable end
2 conductors
Maximum tightening torque / Screw size
Mounting
Fixing on 5 rail
Terminal referencing
Bus jumper (Ith: 5 A)
Compatibility with the plastic maintaining clamp
Compatibility with the metal maintaining clamp
Protection module
Clip-in legends
Wire connection method

RXM2ppppp (1)
RXM 4ppppp
Mixed

Conventional thermal current (Ith)


Maximum operating voltage

Insulation characteristics

RXM 3ppppp

10

0.5 1.5 mm2


AWG 20AWG 16

0.51.5 mm2 - AWG 20AWG 16


0.252.5 mm2 - AWG 22AWG 14

Nm

0.251 mm2 - AWG 22AWG 17


1 / M3 screw
On 35 mm 5 rail / on panel
By red plastic clip
IEC, NEMA
Yes
Yes
Yes
All RXM 040W, RXM 041pp, RXM 021pp
Yes
Screw connector

0.251 mm2
AWG 22AWG 17

By metal
compression
spring

By red plastic clip

No

No
Screw clamp
terminals

(1) When mounting relay RXM2ppppp on socket RXZE2Mpppp, the thermal current must not exceed 10A.

Presentation :
page 22

24

Characteristics :
pages 23 and 24

References :
pages 25 and 26

Dimensions :
pages 27 and 28

Schemes :
page 29

Zelio Relay - plug-in relays

References

RXM miniature relays

Miniature relays without LED (sold in lots of 10)


Control
circuit
voltage

Number and type of contacts - Thermal current (Ith)


2 C/O - 12 A
Unit
reference

106658

RXM pAB1F7

3 C/O - 10 A
Weight

Unit
reference

kg

4 C/O - 6 A
Weight

Unit
reference

kg

Weight
kg

c 12

RXM 2AB1JD

0.037

RXM 3AB1JD

0.037

RXM 4AB1JD

0.037

c 24

RXM 2AB1BD

0.037

RXM 3AB1BD

0.037

RXM 4AB1BD

0.037

c 48

RXM 2AB1ED

0.037

RXM 3AB1ED

0.037

RXM 4AB1ED

0.037

c 110

RXM 2AB1FD

0.037

RXM 3AB1FD

0.037

RXM 4AB1FD

0.037

c 220

RXM 4AB1MD

0.037

a 24

RXM 2AB1B7

0.037

RXM 3AB1B7

0.037

RXM 4AB1B7

0.037

a 48

RXM 2AB1E7

0.037

RXM 3AB1E7

0.037

RXM 4AB1E7

0.037

a 120

RXM 2AB1F7

0.037

RXM 3AB1F7

0.037

RXM 4AB1F7

0.037

a 230

RXM 2AB1P7

0.037

RXM 3AB1P7

0.037

RXM 4AB1P7

0.037

a 240

RXM 4AB1U7

0.037

1
2
3

106657

Miniature relays with LED (sold in lots of 10)

RXM pAB2F7

c 12

RXM 2AB2JD

0.037

RXM 3AB2JD

0.037

RXM 4AB2JD

0.037

c 24

RXM 2AB2BD

0.037

RXM 3AB2BD

0.037

RXM 4AB2BD

0.037

c 48

RXM 2AB2ED

0.037

RXM 3AB2ED

0.037

RXM 4AB2ED

0.037

c 110

RXM 2AB2FD

0.037

RXM 3AB2FD

0.037

RXM 4AB2FD

0.037

c 125

RXM 4AB2GD

0.037

a 24

RXM 2AB2B7

0.037

RXM 3AB2B7

0.037

RXM 4AB2B7

0.037

a 48

RXM 2AB2E7

0.037

RXM 3AB2E7

0.037

RXM 4AB2E7

0.037

a 120

RXM 2AB2F7

0.037

RXM 3AB2F7

0.037

RXM 4AB2F7

0.037

a 230

RXM 2AB2P7

0.037

RXM 3AB2P7

0.037

RXM 4AB2P7

0.037

Miniature relays with low level contacts, without LED (sold in lots of 10)
Control
circuit
voltage

4 C/O - 3 A

106558

Number and type of contacts


Thermal current (Ith)
Unit
reference

RXM 4GB1F7

Weight
kg

c 12

RXM 4GB1JD

0.037

c 24

RXM 4GB1BD

0.037

c 48

RXM 4GB1ED

0.037

c 110

RXM 4GB1FD

0.037

a 24

RXM 4GB1B7

0.037

a 48

RXM 4GB1E7

0.037

a 120

RXM 4GB1F7

0.037

a 230

RXM 4GB1P7

0.037

c 12

RXM 4GB2JD

0.037

c 24

RXM 4GB2BD

0.037

c 48

RXM 4GB2ED

0.037

c 110

RXM 4GB2FD

0.037

a 24

RXM 4GB2B7

0.037

a 48

RXM 4GB2E7

0.037

a 120

RXM 4GB2F7

0.037

a 230

RXM 4GB2P7

0.037

a 240

RXM 4GB2U7

0.037

6
7

106657

Miniature relays with low level contacts, with LED (sold in lots of 10)

RXM 4GB2F7

8
9
10

25

References (continued)

Control
circuit
voltage

2
RXZE2M114M
+
Relais RXM 4AB2F7

RXM miniature relays

Miniature relays without LED (sold in lots of 100)

106016

Zelio Relay - plug-in relays

V
c 12
c 24
c 48
c 110
c 220

Number and type of contacts - Thermal current (Ith)


2 C/O - 12 A
Unit
Weight
reference
kg

RXM 2AB1BDTQ
0.037

a 24
a 48
a 120
a 230

RXM 2AB1B7TQ

RXM 2AB1F7TQ
RXM 2AB1P7TQ

Miniature relays with LED (sold in lots of 100)

106017

c 24
a 24
a 230

RXM 2AB2B7TQ
RXM 2AB2P7TQ

4 C/O - 6 A
Unit
reference

Weight

RXM 4AB1JDTQ
RXM 4AB1BDTQ
RXM 4AB1EDTQ
RXM 4AB1FDTQ
RXM 4AB1MDTQ

kg
0.036
0.036
0.036
0.036
0.036

0.037

0.037
0.037

RXM 4AB1B7TQ
RXM 4AB1E7TQ
RXM 4AB1F7TQ
RXM 4AB1P7TQ

0.036
0.036
0.036
0.036

0.037
0.037

RXM 4AB2BDTQ
RXM 4AB2B7TQ
RXM 4AB2P7TQ

0.036
0.036
0.036

Sockets

Contact terminal
arrangement
Mixed

Connection

Relay type

Sold in
lots of
10

Unit
reference
RXZE2M114 (1)

Screw clamp terminals

RXM2pppp (3)
RXM 4pppp
RXM2pppp (3)
RXM 4pppp
RXM 2pppp
RXM 3pppp
RXM 4pppp

10

RXZE2M114M (1)

0.056

10
10
10

RXZE2S108M (2)
RXZE2S111M (1)

0.058
0.066
0.070

For
use with

Sold in
lots of

Unit
reference

V
c 6...250

All sockets

20

RXM040W

kg
0.003

RC circuit

a 24...60
a 110...240

All sockets
All sockets

20
20

RXM041BN7
RXM041FU7

0.010
0.010

Varistor

a/c 6...24
a/c 24...60
a/c 110...240

All sockets
All sockets
All sockets

20
20
20

RXM021RB
RXM021BN
RXM021FP

0.030
0.030
0.030

Screw connector
Separate

Screw connector

RXZE2S114M (1)

Weight
kg
0.048

Protection modules
RXZE2S114M
+
Relais RXM 4AB2F7

Description

Diode

106018

6
7

RXM041pp7

Weight

Timing relays
Description
535195

2 or 4 timed C/O contacts


(function A)

For
use with
Sockets RXZEppppp

Unit
reference
RE XL2pp (4)
RE XL4pp (4)

Weight
kg

Weight
kg
0.001
0.005
0.005

Accessories
Description

536484

RE XL4pp

Voltage

RXZ 400

Metal maintaining clamp


Plastic maintaining clamp
Bus jumper 2-pole (Ith: 5 A)
Mounting adapter
for 5 rails (5)
Mounting adapter
with fixing lugs for panel
Clip-in legends

For
use with
All sockets
All sockets
All sockets with separate contacts

Sold in
lots of
10
10
10

Unit
reference
RXZ400
RXZ R335

All relays

10

RXZE2DA

0.004

All relays

10

RXZE2FA

0.002

All relays (sheet of 108 legends)


All sockets except RXZ E2M114

10
10

RXZ L520
RXZ L420

0.080
0.001

RXZS2

(1) Thermal current Ith: 10A


(2) Thermal current Ith: 12A
(3) When mounting relay RXM2ppppp on socket RXZE2Mpppp, the thermal current must not exceed 10A.
(4) Please consult the "Zelio Time timing relays" catalogue.
(5) Test button becomes inaccessible.

10
Presentation :
page 22

26

Characteristics :
pages 23 and 24

References :
pages 25 and 26

Dimensions :
pages 27 and 28

Schemes :
page 29

Zelio Relay - plug-in relays

Dimensions

RXM miniature relays

Dimensions

Miniature relays
RXMpppppp
Common view

RXM 2
Pin side view

RXM 3

21
40

4,4 4,4 4,4

27

6,3 6,3 4,2 4,2

6,6 6,6

RXM 4

21

2,5

21
2,5

2,5

2,5

13,2

4,4
2,5

13,2

2,5
13,2

Sockets
RXZE2M114

RXZE2M114M

40

43
19

25,5

17

(4)
14
5

32

22

12

11

(2)

A2
14

9
23
7

30

A1
13

39,5

34

24 14
6

42

32

22 12

(2)

(3)

A2
14

A1

41

31

21

41

31

21

13
11

12

11

10

12

11

10

(4)

21

50
7

30

80

61

(1)

44

40

24
6

44
8
42

3,5

(3)

79

(1)

34
7

23,5

67

27

69

Common side view

RXZE2S108M

RXZE2S111M

RXZE2S114M

61

19

44
8

14
5

34

42
4

12
1

32

21
9

8
24

31

21 11

12
44

11
34

10 9
24 14

8
42

7
32

6
5
22 12

14
5

22
3

41

11

12
2

70

A2

A1

14

13

38

38

38

(5)
29

23
7

31

(2)

3,5

(3)

11
9

79

(1)

41
12

A2

A1
14

13

A2

A1
14

13

23,5

23,5

23,5

27

27

27

(1) Relays
(2) Protection module
(3) Maintaining clamp
(4) 2 elongated holes 3.5 x 6.5
(5) 2 bus jumpers

10

27

Zelio Relay - plug-in relays

Dimensions (continued)

RXM miniature relays

Dimensions (continued)

Plastic clamp and clip-in legends


RXZ R335

RXZ L420

57
12

26,5
(1)

94,5

27

Mounting on all sockets (1)

14,2

3
81

(1) Clip-in legends for all sockets except


RXZ E2M114

Bus jumper

Metal clamp

RXZS2

RXZ400

7,3

22

25

2,2

Mounting on sockets with separate contacts


(view from below)
Example of bus jumper mounting on sockets

22

(1)

(1)

2,3

42

(2)

(2)

0,

6
(1) 2 bus jumpers (polarity A2)
(2) 2 bus jumpers (polarity A1)

RXZE2FA

38

43

38

Mounting adapter for panel

RXZE2DA

48

Mounting adapter for rails (1)

8
3

3,5

3,5
49

4
24

24

23

48

51

(1) Test button becomes inaccessible

10
Presentation :
page 22

28

Characteristics :
pages 23 and 24

References :
pages 25 and 26

Dimensions :
pages 27 and 28

Schemes :
page 29

Zelio Relay - plug-in relays

Schemes

RXM miniature relays

Schemes

Miniature relays

A2
A1

44

42

12
5

42
8

12

22

32

12
5

22
6

32
7

42
8

14
9

44
12

14
7

24
8

34
9

14
9

24
10

34
11

44
12

11
13

41
14

21

21

31

41
14

A2

31
14

11
13

A1

11
13

A2

41

34

32

A1

31

24

22

21

14

12

A2
A1

11

34

32

31

24

22

RXM 4ppppp

21

14

12

A2
A1

11

44

42

RXM 3ppppp

41

14
11

12

RXM 2ppppp

A1

2
3

A2

Symbols shown in blue correspond to Nema marking.

Sockets
RXZE2M114

4
42

RXZE2M114M

6
7
34 24
8
5
44 14
3
2
1
32 22 12

8
44

7
6
34 24

5
14

4
42

3
32

1
12
1

2
22

5
9

14
A2
12
41

13
A1
11
31

9
11
10
21

14

13

A2
14
41 31
12 11

A1
13
21
10

11
9

Symbols shown in blue correspond to Nema marking.


RXZE2S108M

RXZE2S111M
9
11
5
14

9
31
6
34

8
21
5
24

7
11
4
14

4
42

1
12

3
32

2
22

1
12

A1

A2

14
A2

RXZE2S114M

12
41
8
44

A1

A2

13
INPUT A1

14
A2

12
41
8
44
4
42

13
INPUT A1

11
31
7
34
3
32

10
21
6
24
2
22

A1

A2

14
A2

9
11
5
14
1
12

13
INPUT A1

Symbols shown in blue correspond to Nema marking.

Protection modules
RXM 040W

RXM 041ppp

RXM 021ppp

A2

A2

A2

+ A1

+ A1

+ A1

9
10

29

Zelio Relay - plug-in relays

536294

Presentation

RUM universal relays

Presentation of the range

The RUM universal relay range comprises:


1 10 A relays with 2 and 3 C/O contacts, with cylindrical or flat (Faston type) pins,
and 3 A low level relays with 3 C/O contacts, with cylindrical pins. All these relays
have the same dimensions.
2 Sockets with mixed or separate contact terminals.
3 Protection modules (diode, RC circuit or varistor) or 1 timer module. All these
modules are common to all sockets.
4 A metal maintaining clamp for all sockets.
5 A 2-pole bus jumper that can be used on sockets with separate contact terminals
in order to simplify cabling when creating an equipotential link between the coil
terminals.
6 Clip-in legends for the sockets.

4
5

Relay description

106663

1 Spring return pushbutton for testing the contacts (green: c, red: a).
2 Mechanical relay status indicator.
3 Removable lock-down door enabling forced maintaining of the contacts for test
sequences or maintenance purposes. During operation, this lock-down door must
always be in the closed position.
4 LED (depending on version) indicating the relay status.
5 Removable legend for relay identification.
6 Area by which the product can be easily gripped.
7 Eight or eleven cylindrical pins.
8 Eight or eleven flat (Faston type) pins

1
2
3
4

4
5

106022

Socket description

Outputs

Sockets with mixed contact terminals (1)


1 Connection by screw connector.
2 Eight or eleven female contacts for the relay cylindrical pins.
3 Location for protection modules or the timer module.
4 Locking component for metal maintaining clamp.
5 A locating slot for mounting on 5 rail.
6 Two fixing holes for panel mounting.

2
6
4

3
Relay supply

Inputs
Relay suppy

106024

106023

Inputs

Sockets with separate contact terminals (2)


1 Connection by screw connector.
Outputs 2 a Eight or eleven female contacts for the relay cylindrical pins.
b Eleven female contacts for the relay flat pins.
2b 3 Location for protection modules or the timer module.
4 Locking component for metal maintaining clamp.
5 Locating slot for mounting on 5 rail with fixing clip.
4
6 Two fixing holes for panel mounting.
7 Location for bus jumpers (see mounting on sockets on page36).
3
Inputs

Outputs

4
2a
3

10

57

Relay supply

Characteristics :
page 31

30

57

5 Relay supply

References :
pages 33 and 34

(1) The inputs are mixed with the relay's supply, with the outputs being located on the opposite
side of the socket.
(2) The inputs and outputs are separated from the relay supply.
Dimensions :
page 35

Schemes :
page 37

Setting-up :
page 39

Zelio Relay - plug-in relays

Characteristics

RUM universal relays

General characteristics
Conforming to standards
Product certifications
Ambient air temperature
around the device

Storage
Operation
Vibration resistance
In operation
conforming to IEC/EN 60068-2-6 Not operating
Degree of protection
Conforming to IEC/EN 60529
Shock resistance
Opening
conforming to IEC/EN 60068-2-27 Closing
Protection category
Mounting position

IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n 14


UL, CSA
- 40 + 85
- 40 + 55
3gn (10...150Hz/ 1 mm / 5g/5 cycles)
4gn (10...150Hz/ 1 mm / 5g/5 cycles)
IP 40
10 gn
10 gn
RT I
Any

C
C

1
2

Insulation characteristics
Rated insulation voltage (Ui)

250 (IEC), 300 (UL, CSA)

Rated impulse withstand voltage (Uimp)

kV

4 (1.2/50 s)

Dielectric strength
(rms voltage)

aV
aV
aV

1550
1550
1500

Conforming to IEC/EN 60947


Between coil and contact
Between poles
Between contacts

Contact characteristics
Relay type
Number and type of contacts

RUMF2ppp
2 C/O

Contact materials

RUMF3ppp
3 C/O

RUMC2ppp
2 C/O

RUMC3App
3 C/O

RUMC3Gpp
3 C/O low level

AgNi

AgAu

10

"C"

10

Conventional thermal
current (Ith)

For ambient
temperature y 55C

Rated operational current


in utilisation categories
AC-1 and DC-1

Conforming to IEC
Conforming to UL

16 / a277V
12 / c28V

Switching current

Minimum

mA

10

Switching voltage

Maximum

a/c 250 (IEC)

Minimum

17

10 / 250a V

3 / 250a V

10 / 28c V

3 / 28c V

VA

2500

750

280

84

mW

170

15

Nominal load (resistive)


Switching capacity

Maximum

a
c

Minimum
Maximum operating rate
In operating cycles/hour

No-load

18 000

Under load

1200

Utilisation coefficient
In millions of operating cycles

Electrical durability
In millions of operating cycles

Resistive load

0.1

Inductive load

See curves below

106

Maximum switching capacity on resistive load


c
Current c

107

1
0,
0,6
0,5

10
3

0,4

105
0

6
7

Reduction coefficient for inductive load a


(depending on power factor cos )
Reduction coefficient (A)

Durability (Number of operating cycles)

Electrical durability of contacts


Resistive load a

20 %

Mechanical durability

1
2
3
Switching capacity (kVA)

A RUM Fppppp, RUM C2ppp, RUM C3Appp

0,3

0,6

0,4

0,2

0,1

28 50

100

150

200
250
Voltage c

B RUM C3Gppp

10

Durability (inductive load) = durability (resistive load) x reduction coefficient.

31

Zelio Relay - plug-in relays

Characteristics (continued)

Coil characteristics

RUM universal relays

Average consumption

Drop-out voltage threshold

Operating time
(response time)

Between coil energisation


and making of the
On-delay contact

Between coil de-energisation


and making of the
Off-delay contact

VA

2...3

1.4
u 0.15 Uc

u 0.1 Uc
ms

20

ms

20

ms

20

ms

20

12

24

48

60

110

120

125

220

230

JD

BD

ED

ND

FD

GD

MD

120

470

1800

2790

10 000

10 000

3700

Min.

9.6

19.2

38.4

48

88

100

176

Max.

13.2

26.4

52.8

66

121

137.5

242

B7

E7

F7

P7

72

290

1700

7200

Min.

19.2

38.4

96

184

Max.

26.4

52.8

132

253

Control circuit voltage Uc


Relay control voltage codes

d.c. supply

Average resistance at 20 C 10%


Operating
voltage limits

Relay control voltage codes


a.c. supply

Average resistance at 20 C 15%


Operating
voltage limits

4
5

Socket characteristics
Socket type

RUZC2M

RUZC3M

RUZSC2M

RUZSC3M

RUZ SF3M

Relay types used

RUM C2ppppp

RUM C3ppppp

RUM C2ppppp

RUM C3ppppp

RUM Fppppp

Contact terminal arrangement

Mixed

Wire connection method

Connector

Product certifications

UL, CSA

Conforming to standards

IEC 61984, e

Electrical characteristics

Conventional thermal current (Ith)

10

Maximum operating voltage

250 (IEC)

Between adjacent output contacts

Vrms

2500

Between input and output contacts

Vrms

2500

Between contacts and 5 rail

Vrms

2500

Insulation characteristics

General characteristics

12

Ambient air temperature


around the device

Operation

- 40+ 55

Storage

- 40+ 85

Degree of protection

Conforming to IEC/EN 60529

IP 20

Cabling

Solid cable
without
cable end

1 conductor

0.52.5 mm2 - AWG 20AWG 14

2 conductors

0.51.5 mm2 - AWG 20AWG 16

Flexible cable
with cable end

1 conductor

0.252.5 mm2 - AWG 22AWG 14

2 conductors

Maximum tightening torque / Screw size

Separate

0.251 mm2 - AWG 22AWG 17


Nm

1 / M3.3 screw

Mounting

On 35 mm 5 rail / on panel

Fixing on 5 rail

By red plastic clip

Terminal referencing

IEC, NEMA

Bus jumper (Ith: 5 A)

No

Compatibility with the metal maintaining clamp

Yes

Timer module

Yes

Protection module

All RUW 24ppp

Clip-in legends
Wire connection method

Yes

No

Yes

Screw connector

10
Characteristics :
page 31

32

References :
pages 33 and 34

Dimensions :
page 35

Schemes :
page 37

Setting-up :
page 39

Zelio Relay - plug-in relays

References

RUM universal relays

References

Relays for standard applications, without LED (sold in lots of 10)

106664

Pins

Cylindrical

RUM ppAB1F7

Flat (Faston type)

Control
circuit voltage

V
c 12
c 24
c 48
c 60
c 110
c 125
c 220

Number and type of contacts - Thermal current (Ith)


2 C/O - 10 A
3 C/O - 10 A
Unit
Weight
Unit
reference
reference
kg
RUM C2AB1JD
0.085
RUM C3AB1JD
RUM C2AB1BD
0.085
RUM C3AB1BD
RUM C2AB1ED
0.085
RUM C3AB1ED

RUM C3AB1ND
RUM C2AB1FD
0.085
RUM C3AB1FD

RUM C3AB1GD

RUM C3AB1MD

a 24
a 48
a 120
a 230

RUM C2AB1B7
RUM C2AB1E7
RUM C2AB1F7
RUM C2AB1P7

0.085
0.085
0.085
0.085

RUM C3AB1B7
RUM C3AB1E7
RUM C3AB1F7
RUM C3AB1P7

0.088
0.088
0.088
0.088

c 12
c 24
c 48
c 110

RUM F2AB1JD
RUM F2AB1BD
RUM F2AB1ED
RUM F2AB1FD

0.080
0.080
0.080
0.080

RUM F3AB1JD
RUM F3AB1BD
RUM F3AB1ED
RUM F3AB1FD

0.082
0.082
0.082
0.082

a 24
a 48
a 120
a 230

RUM F2AB1B7
RUM F2AB1E7
RUM F2AB1F7
RUM F2AB1P7

0.080
0.080
0.080
0.080

RUM F3AB1B7
RUM F3AB1E7
RUM F3AB1F7
RUM F3AB1P7

0.082
0.082
0.082
0.082

Weight
kg
0.088
0.088
0.088
0.088
0.088
0.088
0.088

Relays for standard applications, with LED (sold in lots of 10)


106663

Cylindrical

RUM ppAB2F7

Flat (Faston type)

c 12
c 24
c 48
c 60
c 110
c 125

RUM C2AB2JD
RUM C2AB2BD
RUM C2AB2ED

RUM C2AB2FD

0.085
0.085
0.085

0.085

RUM C3AB2JD
RUM C3AB2BD
RUM C3AB2ED
RUM C3AB2ND
RUM C3AB2FD
RUM C3AB2GD

0.088
0.088
0.088
0.088
0.088
0.088

a 24
a 48
a 120
a 230

RUM C2AB2B7
RUM C2AB2E7
RUM C2AB2F7
RUM C2AB2P7

0.085
0.085
0.085
0.085

RUM C3AB2B7
RUM C3AB2E7
RUM C3AB2F7
RUM C3AB2P7

0.088
0.088
0.088
0.088

c 12
c 24
c 48
c 110

RUM F2AB2JD
RUM F2AB2BD
RUM F2AB2ED
RUM F2AB2FD

0.084
0.084
0.084
0.084

RUM F3AB2JD
RUM F3AB2BD
RUM F3AB2ED
RUM F3AB2FD

0.082
0.082
0.082
0.082

a 24
a 48
a 120
a 230

RUM F2AB2B7
RUM F2AB2E7
RUM F2AB2F7
RUM F2AB2P7

0.084
0.084
0.084
0.084

RUM F3AB2B7
RUM F3AB2E7

0.082
0.082
0.082
0.082

RUM F3AB2F7
RUM F3AB2P7

Relays with low level contacts, with LED (sold in lots of 10)
Pins

Cylindrical

Control
circuit voltage

V
c 24
c 48

Number and type of contacts


Thermal current (Ith)
3 C/O - 3 A
Unit
Weight
reference
kg
RUM C3GB2BD
0.086
RUM C3GB2ED
0.086

a 24
a 48
a 120
a 230

RUM C3GB2B7
RUM C3GB2E7
RUM C3GB2F7
RUM C3GB2P7

0.086
0.086
0.086
0.086

33

2
3
4
5
6
7
8
9
10

References (continued)

Sockets

Contact terminal
arrangement
Mixed

Separate

Connection

Relay type

Sold in
lots of

Unit
reference

Screw connector

RUMC2ppppp

10

RUZC2M

0.054

RUMC3ppppp

10

RUZC3M

0.054

RUMC2ppppp

10

RUZSC2M

0.095

RUMC3ppppp

10

RUZSC3M

0.100

RUMF2pppp

10

RUZSF3M

0.095

Sold in
lots of

Unit
reference

Screw connector

Protection modules
Description

For
use with

Voltage

106027

RUW 241P7

Weight
kg

Diode

All sockets

c 6250

10

RUW240BD

0.004

RC circuit

All sockets

a 110240

10

RUW241P7

0.004

Varistor

All sockets

a/c 24

10

RUW242B7

0.004

a/c 240

10

RUW242P7

0.004

Timer module
Description

For
use with

Voltage

Reference

V
Multifunction

106028

RUW 101MW

All sockets

Weight
kg

RUW101MW

a/c 24 240

0.020

Timing relays
Description

For
use with

Reference

2 timed C/O contacts


On sockets RUZCpM
(single-function or multifunction)

RE48App
(1)

Weight
kg

Accessories

6
536485

Description

535203

RUZ C200

Weight
kg

RUMF3pppp
RUZ C3M + relais RUM C3ppppp

RUM universal relays

References (continued)

106025

Zelio Relay - plug-in relays

For
use with

Sold in
lots of

Unit
reference

Metal maintaining clamp

All sockets

10

RUZC200

0.001

Bus jumper 2-pole (Ith : 5 A)

All sockets with separate contacts

10

RUZS2

0.005

Clip-in legends

All relays
(sheet of 108 legends)

10

RXZ L520

0.080

All sockets with separate contacts

10

RUZL420

0.001

RUZ S2

(1) Please consult the "Zelio Time timing relays" catalogue.

Characteristics :
page 31

References :
pages 33 and 34

8
9
10

34

Dimensions :
page 35

Schemes :
page 37

Setting-up :
page 39

Weight
kg

Zelio Relay - plug-in relays

Dimensions

RUM universal relays

Dimensions

Universal relays

RUMFpp

55

35

35

RUMCpp

35

53

35

Sockets
Common side view

RUZC2M

RUZC3M

22
24

22

(1)

34

32

24

22

14

12

(2)

A2

21

11

27
89

2
1

INPUT A2
10
A2 A2

A1

10

11

INPUT A1
2

A2
7

63

10

37

37

8
INPUT A2
7

74

(3)

12 14

31
10

21
11

30

30

38

38

INPUT A1
2
11

A1
1

93
RUZSC2M

RUZSC3M

63

45
19

19

24
6

21
8

92

12
4
14
3

6
7

(3)

40
102

105

(2)
A1
2

34
9

24
7

14
3

32

22

12

30

29

36

75

7
8

A2
10

(4)
4

29
75

11
1

A2
7

(4)

21
6

7 6 5
8
4
9
3
10
2
11 1

2
8

(2)

(1)

31
11

40

(1)
(3)

11
1

92

22
5

A1
2

32
36

102
105

(1) Relays
(2) Protection module
(3) Maintaining clamp
(4) 2 bus jumpers

10

35

Zelio Relay - plug-in relays

Dimensions (continued)

RUM universal relays

Dimensions (continued)

Sockets (continued)
RUZ SF3M

63

21
9

31
8

11
7

24
6

34
5

14
4

22

32

12

(1)
92

(3)

(2)
A2
B

(4)
46

29

27

A1
A

36

104

(1) Relays
(2) Protection module
(3) Maintaining clamp
(4) 2 bus jumpers

Metal maintaining clamps and plastic legends


Mounting

35

RUZ C200

108

0,

RUZL420

32
12

59,6

14,2

Bus jumper
RUZS2

Mounting on sockets with separate contacts (view from below)


Example of bus jumper mounting on sockets

(1)

(1)

(2)

(2)

8,5

3,3

35,4

32
2,3

10

(1) 2 bus jumpers (polarity A2)


(2) 2 bus jumpers (polarity A1)

Characteristics :
page 31

36

References :
pages 33 and 34

Dimensions :
page 35

Schemes :
page 37

Setting-up :
page 39

Zelio Relay - plug-in relays

Schemes

RUM universal relays

Schemes

Universal relays

1
24

A2

21

A1

34

22

31

14

32

12

A2
A1

11

34

RUMF3ABppp

31

24

32

21

14

22

12

A2
A1

11

24

RUMC3ppppp

21

14

22

11

12

RUMp2ABppp

2
RUMC2ABppp

RUMF2ABppp

12
4
14

A1

22

11

24

A2


21

RUMC3ppppp

12
4

22
6

14
7

24
9

11
A (+)

21
B( )

A1

A2

22
12

RUMF3ABppp

21
6

24

14 3
A1

32

9 34
2

10
11
31

1
11

A2

12
4

32
5

22
6

14
7

34


24
9

11
A (+)

31

21
B( )

A1

A2

Symbols shown in blue correspond to Nema marking.

Sockets
RUZ C2M
6

RUZ C3M

RUZ SC2M

24 22

12

14

34

32

24

22

14 12

6
7

7
A2

7
A2

8
21

6 5
7

9
10

1
11

2
A1

10 10
A2 A2

11
31

6
21

4
12
3
14

1
11
8
21

6
21
7
24
5
22

11
31
8
32
9
34

4
5

3
11 1

RUZ SC3M

5
22
6
24

1
11

2
A1

7
A2

9
10

2
A1

10
A2

6 5

1
11
4
12
3
14

3
11 1

2
A1

Symbols shown in blue correspond to Nema marking.


RUZ SF3M
9
21
6
24

8
31
5
34

7
11
4
14

3
22

2
32

1
12

B
A2

8
9

A
A1

Symbols shown in blue correspond to Nema marking.

10

37

Zelio Relay - plug-in relays

Schemes (continued)

RUM universal relays

Schemes (continued)

Protection modules
RUW 240BD

RUW 241P7

RUW 242pp

A2

A2

A2

+ A1

+ A1

+ A1

2
3
4
5
6
7
8
9
10
Characteristics :
page 31

38

References :
pages 33 and 34

Dimensions :
page 35

Schemes :
page 37

Setting-up :
page 39

Zelio Relay - plug-in relays

Setting-up

RUM universal relays

Multifunction timer module RUW 101MW


Programming

Timing range selection

Function Timing range


selection selection
0.11 s

0.110 s

0.11 min

110 min

0.11 h

0.11 day

110 h

110 days

2
Function selection
Series control

Monostable with
maintained control
Wu

Series control

Flashing relay,
starting On-delay phase
Bi

Series control

Flashing relay,
starting Off-delay phase
Bp

Series control

Off-delay timer
R

R
t

t t

U
.1/.4
.1/.2

Monostable, starting
on de-energisation
Wa

On-delay Timer
Es

Control by external contact


(S)

t t

U
S

A2

U
S
.1/.4
.1/.2

Control by external contact


(S)

.1/.4
.1/.2

Control by external contact


(S)

U
.1/.4
.1/.2

.1/.4
.1/.2

Monostable
with pulse control
Ws

U
.1/.4
.1/.2

Control by external contact


(S)

U
.1/.4
.1/.2

Control scheme

B1

On-delay Timer
E

Function diagram

A1

Control

A2

Function

A1

Selection

U
S
.1/.4
.1/.2

Power off

Contact open

U : voltage

S : external control

Power on

Contact closed

R : relay RUM ppp

t : adjustable time delay

10

39

Zelio Relay - plug-in relays

Presentation

Presentation of the range

106035

RPM power relays

A metal maintaining clamp for single-contact relays.

3
1

Relay description

1 Spring return pushbutton for testing the contacts (green: c, red: a).
2 Mechanical relay status indicator.
3 Removable lock-down door enabling forced maintaining of the contacts for test
sequences or maintenance purposes. During operation, this lock-down door must
always be in the closed position.
4 LED (depending on version) indicating the relay status.
5 Removable legend for relay identification.
6 Four notches for rail mounting adapter or panel mounting adapter with fixing lugs.
7 Five, eight, eleven or fourteen Faston type pins.
8 Area by which the product can be easily gripped.
9 Mounting adapter enabling direct mounting of the relay on a panel.
10 Mounting adapter enabling direct mounting of the relay on a 5 rail.

106669

The RPM power relay range comprises:


1 15 A relays with 1, 2, 3 and 4 C/O contacts.
2 Sockets with mixed contact terminals.
3 Protection modules (diode, RC circuit or varistor) or 1 timer module. All these
modules are common to all the sockets except for the timer module, which can
only be used on the 3-pole or 4-pole sockets.

2
3
4
5

7 6

5
106674

106673

106672

6
7
10

106040

Socket description

5
1

Outputs

Sockets with mixed contact terminals (1)


1 Connection by screw clamp terminals.
2 Five, eight, eleven or fourteen female contacts for the relay pins.
3 Location for protection modules or the timer module.
4 Locating slot for mounting on rail with fixing clip.
5 Two or four fixing holes for panel mounting.
(1) The inputs are mixed with the relay's supply, with the outputs being located on the opposite
side of the socket.

Relay supply

9
4

Inputs

10
Characteristics :
page 41

40

References :
page 43

Dimensions :
page45

Schemes :
page 47

Zelio Relay - plug-in relays

Characteristics

RPM power relays

General characteristics
Conforming to standards
Product certifications
Ambient air temperature
around the device

Storage
Operation
Vibration resistance
In operation
conforming to IEC/EN 60068-2-6 Not operating
Degree of protection
Conforming to IEC/EN 60529
Shock resistance
Opening
conforming to IEC/EN 60068-2-27 Closing
Protection category
Mounting position

IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n 14


UL, CSA
- 40 + 85
- 40 + 55
3gn (10...150Hz/ 1 mm / 5g/5 cycles)
5gn (10...150Hz/ 1 mm / 5g/5 cycles)
IP 40
15 gn
15 gn
RT I
Any

C
C

1
2

Insulation characteristics
Rated insulation voltage (Ui) Conforming to IEC/EN 60947
Rated impulse withstand voltage (Uimp)
Dielectric strength
Between coil and contact
(rms voltage)
Between poles
Between contacts

V
kV
aV
aV
aV

250 (IEC), 300 (UL, CSA)


4 (1.2/50 s)
1550
1550
1500

RPM 1ppp
1 C/O
AgNi
15

Contact characteristics
Relay type
Number and type of contacts
Contact materials
Conventional thermal
For ambient
current (Ith)
temperature y 55 C
Rated operational current
Conforming to IEC
in utilisation categories
AC-1 and DC-1
Conforming to UL
Switching current
Minimum
Switching voltage
Maximum
Minimum
Nominal load (resistive)

"C"
O

Switching capacity

Maximum

a
c

Maximum operating rate


In operating cycles/hour

Minimum
No-load
Under load

Electrical durability
In millions of
operating cycles

106

105

4
3,75
Switching capacity (kVA)

4
5
6

20 %
10
0.1
See curves below

1
0,
0,6
0,5

0,4

0,3

0.06

Reduction coefficient for inductive load a


(depending on power factor cos )
Reduction coefficient (A)

Durability (Number of operating cycles)

107

RPM 4ppp
4 C/O

15
7.5
15
10
a/c 250 (IEC)
17
15 / 250a V
15 / 28c V
3750
420
170
18 000
1200

In millions of
operating cycles
Resistive load
Inductive load

Electrical durability of contacts


Resistive load a

RPM 3ppp
3 C/O

Maximum switching capacity on resistive load


c
Current c

Utilisation coefficient
Mechanical durability

A
A
A
mA
V
V
A
A
VA
W
mW

RPM 2ppp
2 C/O

15
10

0,1

0,6

0,4

0,2

28 50

100

150

200
250
Voltage c

Durability (inductive load) = durability (resistive load) x reduction coefficient.

10

41

Zelio Relay - plug-in relays

Characteristics (continued)

RPM power relays

Coil characteristics

Relay type
Average consumption

RPM 2ppp
1.2
0.9

RPM 3ppp
1.5
1.7

RPM 4ppp
1.5
2

ms

RPM 1ppp
0.9
0.7
u 0.15 Uc
u 0.1 Uc
20

25

25

20

ms

20

25

25

20

ms

20

ms

20

12

24

48

110

120

230

RPM 1ppp
RPM 2ppp
RPM 3ppp
RPM 4ppp
Min.
Max.

V
V

JD
180
160
100
96
9.6
13.2

BD
750
650
400
388
19.2
26.4

ED
2600
2600
2600
1550
38.4
52.8

FD
13 100
11 000
8600
7340
88
121

RPM 1ppp
RPM 2ppp
RPM 3ppp
RPM 4ppp
Min.
Max.

V
V

B7
160
180
103
84.3
19.2
26.4

E7
720
770
770
338
38.4
52.8

F7
4430
4430
2770
2220
96
132

P7
15 720
15 000
12 000
9120
184
253

Drop-out voltage threshold


Operating time
(response time)

Between coil
energisation
and making of the
On-delay contact

Between coil
de-energisation
and making of the
Off-delay contact

a
c
a
c
a

VA
W

Control circuit voltage Uc

Relay control voltage codes


d.c. supply
Average resistance
at 20 C 10%

Operating
voltage limits

Relay control voltage codes


a.c. supply
Average resistance
at 20 C 15%

Operating
voltage limits

5
6
7

Socket characteristics
Socket type

RPZ F1

RPZ F2

RPZ F3

RPZ F4

Relay types used

RPM 1ppp

RPM 2ppp

RPM 3ppp

RPM 4ppp

Protection module types used

RXM02ppp
RXM04ppp

RXM02ppp
RXM04ppp

RUW24ppp

RUW24ppp

Contact terminal arrangement


Wire connection method
Product certifications
Conforming to standards

Electrical characteristics

Conventional thermal current (Ith)


Maximum operating voltage

A
V

16
250 (IEC)

Between adjacent output contacts


Between input and output contacts
Between contacts and 5 rail

Vrms
Vrms
Vrms

2500
2500
2500

Ambient air temperature


around the device

C
C

- 40+ 55
- 40+ 85
IP 20
0.51.5 mm2 - AWG 20AWG 16 0.52.5 mm2 - AWG 20AWG 14
0.51.5 mm2 - AWG 20AWG 16 0.52.5 mm2 - AWG 20AWG 14

Insulation characteristics

General characteristics

8
9
10

Mixed
Screw clamp terminals
UL, CSA
IEC 61984, e

Operation
Storage
Degree of protection
Conforming to IEC/EN 60529
Cabling
Solid cable
1 conductor
without
2 conductors
cable end
Flexible cable 1 conductor
with cable end 2 conductors
Maximum tightening torque / Screw size
Mounting
Fixing on 5 rail
Terminal referencing
Compatibility with the metal maintaining clamp
Timer module
Protection module
Clip-in legends
Wire connection method
Screw clamp terminals

Presentation :
page 40

42

Characteristics :
page 41

Nm

0.251 mm2 - AWG 22AWG 17 0.251.5 mm2 - AWG 22AWG 16


0.251 mm2 - AWG 22AWG 17 0.251.5 mm2 - AWG 22AWG 16
1 / M3 screw
1 / M3.5 screw
On 35 mm 5 rail / on panel
By red plastic clip
IEC, NEMA
Yes
No
No
Yes
RXM 040W, RXM 041pp, RXM 021pp
RUW 24pp
No

References :
page 43

Dimensions :
page 45

Schemes :
page 47

Zelio Relay - plug-in relays

References

RPM power relays

Power relays without LED (sold in lots of 10)

106670

Control
circuit
voltge
V
c 12

Number and type of contacts - Thermal current (Ith)


1 C/O - 15 A
2 C/O - 15 A
3 C/O - 15 A
Unit
Weight
Unit
Weight
Unit
Weight
reference
reference
reference
kg
kg
kg
RPM11JD
0.026
RPM21JD
0.036
RPM31JD
0.054

4 C/O - 15 A
Unit
Weight
reference
kg
0.071
RPM41JD

c 24

RPM11BD

0.026

RPM21BD

0.036

RPM31BD

0.054

RPM41BD

0.071

c 48

RPM11ED

0.026

RPM21ED

0.036

RPM31ED

0.054

RPM41ED

0.071

c 110

RPM11FD

0.026

RPM21FD

0.036

RPM31FD

0.054

RPM41FD

0.071

a 24

RPM11B7

0.026

RPM21B7

0.036

RPM31B7

0.054

RPM41B7

0.071

a 48

RPM11E7

0.026

RPM21E7

0.036

RPM31E7

0.054

RPM41E7

0.071

a 120

RPM11F7

0.026

RPM21F7

0.036

RPM31F7

0.054

RPM41F7

0.071

a 230

RPM11P7

0.026

RPM21P7

0.036

RPM31P7

0.054

RPM41P7

0.071

1
2

RPM 41BD

106669

Power relays with LED (sold in lots of 10)

RPM 42BD

c 12

RPM12JD

0.026

RPM22JD

0.036

RPM32JD

0.054

RPM42JD

0.071

c 24

RPM12BD

0.026

RPM22BD

0.036

RPM32BD

0.054

RPM42BD

0.071

c 48

RPM12ED

0.026

RPM22ED

0.036

RPM32ED

0.054

RPM42ED

0.071

c 110

RPM12FD

0.026

RPM22FD

0.036

RPM32FD

0.054

RPM42FD

0.071

a 24

RPM12B7

0.026

RPM22B7

0.036

RPM32B7

0.054

RPM42B7

0.071

a 48

RPM12E7

0.026

RPM22E7

0.036

RPM32E7

0.054

RPM42E7

0.071

a 120

RPM12F7

0.026

RPM22F7

0.036

RPM32F7

0.054

RPM42F7

0.071

a 230

RPM12P7

0.026

RPM22P7

0.036

RPM32P7

0.054

RPM42P7

0.071

5
6
7
8
9
10

43

References (continued)

Contact terminal
arrangement
Mixed

Connection

Relay type

Unit
reference

RPM 1ppp
RPM2ppp
RPM3ppp

Sold in
lots of
10
10
10

RPZF1
RPZF2
RPZF3

Weight
kg
0.042
0.054
0.072

Screw clamp
terminals

RPM4ppp

10

RPZF4

0.094

Voltage

Socket type

Sold in
lots of

Unit
reference

V
c 6...250

RPZF1RPZF2

20

RXM040W

kg
0.003

10

RUW240BD

0.004

a 24...60

RPZF3
RPZF4
RPZF1RPZF2

20

RXM041BN7

0.010

a 110...240

RPZF1RPZF2

20

RXM041FU7

0.010

10

RUW241P7

0.004

a/c 6...24

RPZF3
RPZF4
RPZF1RPZF2

20

RXM 021RB

0.030

a/c 24...60

RPZF1RPZF2

20

RXM021BN

0.030

a/c 110...240

RPZF1RPZF2

20

RXM021FP

0.030

a/c 24

RPZF3
RPZF4
RPZF3
RPZF4

10

RUW242B7

0.004

10

RUW242P7

0.004

Protection modules

Description

RPZ F2 + relay RPM 22F7

Diode

RC circuit

106044

RPM power relays

Sockets

106043

Zelio Relay - plug-in relays

RUW 24ppp
Varistor

a/c 240

Timer module (1)


Description

106045

Multifunction

Weight

Voltage
V
a/c 24 240

Reference

RPZ F3
RPZ F4

RUW101MW

Weight
kg
0.020

Accessories
Description

For
use with
RPZ F1

Sold in
lots of
20

Unit
reference
RPZ R235

RPM 1ppp
RPM2ppp
RPM3ppp
RPM4ppp

20
20
20
20

RPZ1DA
RXZE2DA
RPZ3DA
RPZ4DA

0.004
0.004
0.004
0.006

Mounting adapters with fixing lugs for panel

RPM 1ppp
RPM2ppp
RPM3ppp
RPM4ppp

20
20
20
20

RPZ1FA
RXZE2FA
RPZ3FA
RPZ4FA

0.002
0.002
0.003
0.004

Clip-in legends
(sheet of 108 legends)

All relays

10

RXZ L520

0.080

Metal maintaining clamp


(for single-pole relays)
Mounting adapters for 5 rail (2)

Socket type

106046

RPZ 1DA

8
RPZ 3FA

(1) See timer module description (selection of functions and time delays) on page39.
(2) Test button becomes inaccessible.

Presentation :
page 40

Characteristics :
page 41

9
10

44

References :
page 43

Dimensions :
page 45

Schemes :
page 47

Weight
kg
0.001

Zelio Relay - plug-in relays

Dimensions

RPM power relays

Dimensions
Power relays

RPM1

27

6,5 6 5

3,5

4,7

6
7

Common side view

RPM2

RPM3

RPM4

4,6 4,6 4,6

4,6 4,6

27

27

7,1 6 4,6 4

4,6

39

4,6 4,6 4,6 4,6

21

31

10

27

40

2,6

2,6

14

10

10

41

10

10

10

14,2

Sockets

12

42
4

12
1

(1)

5
6

80

(2)

14

40

40

44

80

(2)
A1

14

13

A2
14

A1
13

11

41

11

12

17

21

71

19

31

A2

40

30

80
RPZ F3

30

RPZ F4

4,5 x 6

4,5 x 6
24
6
42

14

22

8
12

34
7

24
6

42
4

68

(1)

68

44

40

44
8

32
3

14

5
22

12
1

40

19

80

26

76

Common side view

4,5 x 6

(3)

14

(1)

4,5 x 6

19

40

RPZF2

19

68

RPZF1

14

30
76

10

21

A2
13
41

11

12

28

A1

14

13
41

12

A1

4,5 x 6

40

A2

40

(2)

11

31

21

10

36

37

46

40

50

11
9

4,5 x 6

10

(1) Relays
(2) Protection module
(3) Maintaining clamp

45

Zelio Relay - plug-in relays

Dimensions (continued)

RPM power relays

Dimensions (continued)

Mounting adapters for 5 rail

50

50

RPZ4DA

24

20

34

44

2,5

23

Mounting adapters with fixing lugs for panel

3,5
16

3,5

19

24

3,5
19

16

38

43

38

38

5
16,5

RPZ4FA

43

RPZ3FA

43

43

RXZE2FA

38

RPZ1FA

24

2,5

23
23

RPZ3DA

2,5

49,5

RXZE2DA

38

RPZ1DA

48

3,5

34

44

Mounting
Mounting adapters for 5 rail (1)

Mounting adapters with fixing lugs for panel

6
7
(1) Test button becomes inaccessible

8
9
10
Presentation :
page 40

46

Characteristics :
page 41

References :
page 43

Dimensions :
page 45

Schemes :
page 47

Zelio Relay - plug-in relays

Schemes

RPM power relays

Schemes

Power relays

1
A2
A1

44

42

41

34

32

31

24

22

21

14

12

A2
A1

11

44

42

RPM 4ppp

41

24

22

21

14

12

A2
A1

11

24

22

RPM 3ppp

21

14

12

A2
A1

RPM 2ppp

11

14

12

11

RPM 1ppp

2
1

12

12

22

12

22

42

12

22

32

42

14
9

14
9

24
12

14
9

24
10

44
12

14
9

24
10

34
11

44
12

21

41
14 ( )

11
13 (+)

21

31

41
14 ( )

A2

A1

13 (+)

14 ( )

11
13 (+)

21
14 ( )

11
13 (+)

A1

A2

A1

A2

A1

11

A2

Symbols shown in blue correspond to Nema marking.

Sockets
RPZ F1

RPZ F2

RPZ F3

RPZ F4

5
14

8
44

5
14

8
44

6
24

5
14

8
44

7
34

6
24

5
14

1
12

4
42

1
12

4
42

2
22

1
12

4
42

3
32

2
22

1
12

5
14
13
A2
A1
INPUT
9
11

14
A2
12
41

13
A1
9
11

14
A2
12
41

10
21

13
A1

9
11

14
A2
12
41

11
31

10
21

13
A1
9
11

Symbols shown in blue correspond to Nema marking.

Protection modules
RXM 040W, RUW 240BD

RXM 041ppp, RUW 241P7

RXM 021ppp, RUW 242pp

A2

A2

A2

+ A1

+ A1

+ A1

7
8
9
10

47

Technical presentation

Zelio Relay - plug-in relays

Relays

Contact types

Symbol

2
3

Configuration
Make contact
(Normally Open)

EU
NO

USA
SPST-NO
DPST-NO
nPST-NO (1)

Break contact
(Normally Closed)

NC

SPST-NC
DPST-NC
nPST-NC (1)

Changeover Contact

CO

SPDT
DPDT
nPDT (1)

Utilisation categories

4
5
6

Category
AC-1

Type of current
a single-phase
a 3-phase

Applications
Resistive or slightly inductive loads.

AC-3

a 3-phase

Starting and braking of squirrel cage motors; reversing


direction of rotation only after stopping of motor.

AC-4

a 3-phase

Starting of squirrel cage motors, inching. Plugging,


reversing direction of rotation.

DC-1

Resistive or slightly inductive loads (2).

AC-14

a single-phase

Control of electromagnetic loads (<72VA), auxiliary


control relays, power contactors, electromagnetic
solenoid valves and electromagnets.

AC-15

a single-phase

Control of electromagnetic loads (>72VA), auxiliary


control relays, power contactors, electromagnetic
solenoid valves and electromagnets.

DC-13

Control of electromagnetic loads, auxiliary control relays,


power contactors, magnetic solenoid valves and
electromagnets.

Protection categories

7
8

Category
RT 0

Explanation
Condition
Unenclosed relay Relay not provided with a protective case.

RT I

Dust protected
relay

Relay provided with a case which protects its mechanism


from dust.

RT II

Flux-proof relay

RT III

Wash-tight relay

Relay capable of being automatically soldered without


allowing the migration of solder fluxes beyond the
intended areas.
Relay capable of being automatically soldered and then
washed to remove flux residues without risk of ingress of
flux or washing solvents.

RT IV

Sealed relay

RT V

Relay provided with a case which has no venting to the


outside atmosphere.

Hermetically
Sealed relay having an enhanced level of sealing.
sealed relay
(1) n = number of contacts.
(2) The switchable voltage can be doubled, for an equal current, by connecting two contacts in
series.

9
10

48

Zelio Relay - plug-in relays

Presentation

Protection modules

Whenever an inductive load is de-energised (coil of a relay or of a contactor), an


overvoltage appears at its terminals. This voltage peak can reach several thousand
volts and a frequency of several MHz.
It is likely to disturb the operation of automation systems which contain electronic
devices.
Protection modules are used to reduce the voltage peak on de-energisation and
they therefore limit the energy of interference signals to a level that will not disturb
surrounding coils and electronic devices.
These modules are used to avoid:
v electromagnetic compatibility problems,
v the deterioration of contact materials,
v the destruction of insulation due to overvoltage,
v the destruction of electronic components.

U
Supply voltage

Energy released

b
v
v
v

Coil voltage with diode protection module (conly)

Disadvantages
increase in relay drop-out time (3 to 4 times the usual time),
no polarity protection,
de-energisation of the relay.

Protection module with varistor


b Advantages
v can be used with a and c supply,
v voltage peak limited to about 2Un,
v little effect on relay drop-out time.

Break

b Disadvantages
v no modification of coils own oscillating frequency,
v limitation of switching frequency.

Limitation of voltage
peaks

Energy
released

6
7

Coil voltage with varistor protection module (aandc)

Protection module with RC circuit


b Advantages
v coil oscillating frequency reduced to about 150Hz,
v voltage peak limited to 3 Un,
v little effect on relay drop-out time.

Break

b Disadvantages
v no protection for low voltages.

U2

U1

S2 (with RC)

2
3

Diode protection module (with or without LED)


b Advantages
v accumulation of energy allowing current flow in the same direction,
v absence of any voltage peaks at the coil terminals,
v low cost.

Break

S1

Coil voltage with RC circuit protection module (aonly)


S1 = S2 = Energy released

10

49

Selection guide

Interfaces

Interfaces for discrete signals

Applications

Electromechanical interface modules

Functions

Input

Width (mm)

17.5

9.5

Contact arrangement

1 N/O
2 N/O
1 C/O

1 N/O

Thermal current

Control voltages

c 110127 V
z 24 V, 48 V
a 115127 V
a 230/240 V

c 24 V, 48 V
a 115127/50 Hz
a 115127/60 Hz
a 230240/50-60 Hz

Indication

Mechanical for contacts


and/or LED for control

LED for control

References

ABR 1E

ABR 2E

Pages

56

62

1
2
3
4
5
6
7
8
9
10

50

Solid state interface modules

1
2
3
4
Output

Input and output


Very low level switching

Input

Output

9.5/17.5

17.5

12

17.5

9.5

1 N/O
2 N/O
1 C/O
1 N/C + 1 N/O

1 N/O

1 C/O

12 A

5A

c 24 V
z 24 V, 48 V
a 115127 V
a 110 V

c 24 V

Mechanical for contacts


and/or LED for control

LED for control

ABR 1S

ABR 2S

ABR 2pB312B

ABS 2E

56

62

62

68

5
5A

c 5, 24, 48 V
a 115127/50 Hz
a 120127/60 Hz
a 230240/50 Hz
a 230240/60 Hz

c 24 V

7
ABS 2S

8
9
10

51

Interfaces

Presentation

For discrete signals

Electromechanical interface modules

ABR-1 electromechanical interface modules are supplied in the form of compact


modules, 17.5 mm wide.
They are designed for interfacing discrete digital control signals exchanged within an
automated system between the processing unit (PLC, numerical controller, etc) and
the other components (contactors, solenoid valves, indicator lamps, proximity
sensors, etc).
These products are based on contactor technology and are notable for their excellent
adaptation to industrial environments, ensured by the fact that they conform to the
most recent IEC 947-5-1 standards.

Composition

816264

The ABR-1 range comprises 2 families :


5

Input interfaces
Input interfaces are designed for switching input signals to the processor and are
characterized by their high degree of contact reliability : less than 1 fault per 100
million operating cycles at c 17 V, 5 mA.
The switching level is sufficiently high to ensure that the interfaces can directly
control most contactors and indicator lamps.

2
1

816265

Output interfaces
Output interfaces are designed for the control of preactuators (contactors, solenoid
valves, etc) for signalling devices (indicators lamps, audible warnings, etc). They are
characterized by a high switching capacity and an average durability 5 times greater
than that of traditional interface modules which incorporate standard relays.

1 Override contacts by pressing button (not holding it down) for a simple and quick
test during setting up or maintenance operations on the installation
2 Green indicator showing the mechanical position of the contacts
3 LED indicating the control signal state
4 Channel identification : 5 individual characters for AB1-R/G or one AB1-SA2
marker tag
5 Connection by screw clamp terminal enabling easy attachment of 2 wires per
terminal. The layout of the connection terminals for both families (input and output)
is designed for rational wiring and a clear separation between the incoming
(processing) and outgoing (power and process control) circuits.

4
1
2

6
7
8
9
10
Presentation:
page 52

52

Characteristics:
page 53

Curves:
page 55

Dimensions, schemes:
page 57

Interfaces

Characteristics

For discrete signals

Electromechanical interface modules

Examples of applications with PLCs


PLC
Positive logic discrete inputs

+/

PLC
Positive logic transistor (or relay) outputs

+/

A2

A1

A2

A1

A2

+
24...125 V

A1

A2

A1

A2

A1

A2

A1

A2

A1

...240 V

(1)
Pushbuttons
Series contacts

2-wire
sensors

3-wire
sensors

Pushbuttons
Series contacts

(1) Essential on inductive loads (can be replaced with peak limiter

(1)

2-wire
sensors

).

Environment
Conforming to standards
Product certifications
Degree of protection
Protective treatment
Flame resistance

Conforming to IEC 529


(protection against direct contact)
Conforming to IEC 695-2-1

Shock resistance
Vibration resistance
Resistance to electrostatic
charges
Resistance to rapid
transients

Conforming to IEC 68-2-27


Conforming to IEC 68-2-6
Conforming to IEC 801-2

Resistance to shock
waves

Conforming to IEC 255-4

Cross-sections which
may be connected

Flexible cable with no cable end


Flexible cable with cable end
Rigid cable

Operating position
Ambient air temperature
around the device
Operating altitude
Installation category
Degree of pollution
Mounting

IEC 947-5-1
UL, CSA, BV, LROS, DNV
IP 00

Conforming to IEC 801-4

Unrestricted operation
Permissible at Un
Storage
Conforming to IEC 947-1
Conforming to IEC 947-5-1

Incandescent wire
Conforming to UL 94
Semi-sinusoidal waves 11ms
1055Hz
Level 3

On power supply
On I/O
Waveform
1.2/50 ms ; 0.5 J

kV
kV
kV
kV
mm2
mm2
mm2
mm2

1 or 2-wire
1 or 2-wire
1-wire
2-wire

U 50 V
U > 50 V

kV

C
C
C
m

TC
850
V0
50 gn
6 gn
8

2
1
0.5
2.5
0.62.5
0.342.5
0.274
0.272.5
Any
- 5+ 40
- 20+ 60
- 40+ 70

7
8

3000
II
3
Standard rails 5 1 4

9
10

53

Interfaces

Characteristics (continued)

For discrete signals

Electromechanical interface modules

Control circuit characteristics (40C ambient temperature)

1
2
3

Type of interface
Rated voltage (Uc)

ABR
1Sp02B
c 24

Current frequency
Energization threshold (at 5 %)
Maximum operating voltage
Maximum drop-out (at 5 %) voltage (Uo)
Maximum current (Un)
Minimum holding current
Maximum dissipated power
Disappearance of voltage
maximum time up to which contact is maintained
Display of control circuit by LED
Built-in protection reversed polarity

Hz
V
V
V
mA
mA
W
ms

15
30
3.2
62
6.6
1.5
3

50/60
16.5
30
3.8
62/55
4.9/5.2
1.5
8

50/60
34
53
8.5
36/32
4.7/5.4
1.5
10

ABR
1Ep12F
c
110...127

75
140
16
15
1.5
1.5
10

No
Yes

Yes
Yes

Yes
Yes

Yes
Yes

5
6

Type of interface
Maximum switching voltage

Conforming to IEC 947-5-1

Operating current frequency


Thermal current Ith
Conforming to IEC 947-1
Rated operating
Conforming to IEC 947-5-1
current (Ie)
Ue : a 230 V
per 1 million operating
cycles
Conforming to IEC 947-5-1
Ue : c 24 V

AC12
AC13
AC14
AC15
DC12
DC13

Minimum switching capacity


Minimum switching voltage
Protection against
For Ik 2.5 kA (a) and 100 A (c)
short-circuits
Typeand value of recommended fuse
Low power switching Number of faults
reliability of contacts per n million operating cycles
(17 V - 5 mA)

aV
cV
aV
cV
Hz
A
A
A
A
A
A
A
mA
V
A

ABR
1ppp1F
a
115...127
50/60
86
140
34
8
2.4
1.5
6

ABR
1Ep11M
a
230...240
50/60
170
264
68
7
2
1.5
5

ABR
1Ep01M
a
230...240
50/60
164
264
78
5.5
1.5
1.5
6

Yes

Yes

No

ABR 1Epppp
252
125
230
125
50/60
2
2
1
1
1
2
1
3
17
gG/gF : 16

ABR 1Spppp
252
125
230
125
50/60
12
4
1
1
1
5
1
3
17
gG/gF : 16

10-8

10-8

Other characteristics

Operating time
at Un and at 20 C

7
8

ABR
1ppp8E
z 48

Contact characteristics

Maximum rated
operating voltage Ue

c/a
c/a
c/a
c/a
50 Hz/60 Hz

ABR
1ppp8B
z 24

Duration of bounce
Contact bridging times
between contact N/C
and N/O
Maximum operating
rate

Between energization of coil and


closing of N/O contact
Between energization of coil and
opening of N/C contact
Between de-energization of coil and
opening of N/O contact
Between de-energization of coil and
closing of N/C contact
Maximum make before break or break
before make time
At no-load
At Ie
ABR-1 (1 N/O or 2 N/O)
ABR-1 (1 C/O or 1 N/C + 1 N/O)

Mechanical durability
inmillions of operating
cycles
Rated isolation voltage Conforming to IEC 947-1
Conforming to VDE 0110 group C
Insulation test voltage Between coil circuit and contact circuits
for 1 min.
Between wired interface and earth
Between independent contacts

ms

12

ms

12

ms

12

ms

12

ms
ms

3
1

Hz
Hz

6
0.5
20 million
10 million

V
V
kV
kV
kV

250
250
4
2.5
1.5

10
Presentation:
page 52

54

Characteristics:
page 53

Curves:
page 55

Dimensions, schemes:
page 57

Interfaces

Curves

For discrete signals

Electromechanical interface modules

Electrical durability of contacts

Test conditions : in accordance with standard IEC 947-5-1 set up for rated control voltage, operating rate : 1800 cycles/hour. (0.5 Hz).

a.c. loads
Operating cycles in millions

Operating cycles in millions

3
2

2
1

3
2

3
4

2
3
4

0
0

6
(A)

AC-12 : control of resistive loads and isolated solid


state loads via optocoupler
cos j 0.9

6
(A)

AC-13 : control of isolated solid state loads


via transformer
cos j 0.65

Operating cycles in millions


3

AC-14 : control of weak electromagnetic loads of


electromagnets 72 VA
make: cos j = 0.3
break: cos j = 0.3
AC-15 : control of electromagnetic loads of
electromagnets> 72 VA
make: cos j = 0.7
break: cos j = 0.4

2
3

5
6

1
2
3
4

0
0

0,5

1,5

2,5

24 V
48 V
127 V
230 V

3
(A)

d.c. loads
Operating cycles in millions

Operating cycles in millions

1 24 V
2 48 V
3 127 V

1
4

3
2
1

0
0

3
3

0,5

1,5

2,5

(A)

DC-12 : control of resistive loads and isolated solid


state loads via optocoupler
L/R 1 ms

3
(A)

DC-13 : control of electromagnets


L/R 2 x (Ue x Ie) in ms.
Ue: rated operating voltage
Ie: rated operating current

10

55

Interfaces

References

For discrete signals

Electromechanical interface modules


Control circuit : a.c. or d.c.

816264

Input interface modules (1) (17.5 mm pitch)


Display

Mechanical (2)
Mechanical (2)
+LED (3)

Composition

1 N/O
1 C/O
1 N/O

2
2 N/O

818215

ABR 1E101M

1 C/O

V
a 230/240
a 230/240
z 24
z 48
c 110...127 (4)
a 115...127
a 230/240
z 24
z 48
c 110...127(4)
a 115...127
a 230/240
z 24
z 48
c 110...127(4)
a 115...127
a 230/240

Enclosure Reference
colour
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey

Output terminals-relays (1) (17.5 mm pitch)

Display

Mechanical (2)

ABR 1E318B
Mechanical (2)
+LED (3)

816265

Control circuit

Composition

1 N/O
2 N/O
1 C/O
1 N/C + 1 N/O
1 N/O

2 N/O

1 C/O

1 N/C + 1 N/O

Commoning links

ABR 1S102B

816273

Description

For common

Commoning
Coil
links in modules
2
8 x 1 mm
a

Control circuit
V
c 24
c 24
c 24
c 24
z 24
z 48
a 115...127
z 24
z 48
a 110
z 24
z 48
a 110
z 24
z 48
a 110
Colour

White
Red
Blue

Enclosure Reference
colour
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey
Grey

Distance
between
cableends
cm
12
2
12
2
12
2

9
10

56

ABR 1S102B
ABR 1S402B
ABR 1S302B
ABR 1S602B
ABR 1S118B
ABR 1S118E
ABR 1S111F
ABR 1S418B
ABR 1S418E
ABR 1S411F
ABR 1S318B
ABR 1S318E
ABR 1S311F
ABR 1S618B
ABR 1S618E
ABR 1S611F
Reference

ABF C08R12W
ABF C08R02W
ABF C08R12R
ABF C08R02R
ABF C08R12B
ABF C08R02B

kg
0.090
0.090
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
Weight
kg
0.090
0.090
0.090
0.090
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
Weight
kg
0.020
0.010
0.020
0.010
0.020
0.010

(1) Connection by screw-clamp.


(2) By green mechanical indicator light for contact(s) activated electrically or mechanically by
pressing the test button.
(3) By green LED illuminated when control signal is present.
(4) With polarization (+ on A1, - on A2).

ABF C08Rppp

Presentation:
page 52

ABR 1E101M
ABR 1E301M
ABR 1E118B
ABR 1E118E
ABR 1E112F
ABR 1E111F
ABR 1E111M
ABR 1E418B
ABR 1E418E
ABR 1E412F
ABR 1E411F
ABR 1E411M
ABR 1E318B
ABR 1E318E
ABR 1E312F
ABR 1E311F
ABR 1E311M

Weight

Characteristics:
page 53

Curves:
page 55

Dimensions, schemes:
page 57

Interfaces

Dimensions,
schemes

For discrete signals

Electromechanical interface modules

Dimensions

ABR 1S

78

74

74

ABR 1E

78

17,5

70,5

17,5

70,5

75

75

63

63

Schemes

c 24 V or a 230 V interfaces with mechanical indication


A1

A1

A2

1 N/C + 1 N/O

A2

A2

2 N/O
A1

1 C/O
A1

A2

1 N/O

4
14

13

14

14

11

12

13

24

23

24

23

12

11

z 24 V or z 48 V interfaces with mechanical indication + LED

A1

A2

A2

1 N/C + 1 N/O
A1

2 N/O
A1

A2

1 C/O
A1

A2

1 N/O

7
14

14

13

11

12

14

13

24

23

24

23

12

11

c / a 110 V or a 230 V interfaces with mechanical indication + LED

A2

A1
(+)

1 N/C + 1 N/O
A1
(+)

A2

A2

2 N/O
A1
(+)

1 C/O
A1
(+)

A2

1 N/O

9
14

13

14
12

11

14

13

24

23

24

23

12

11

10

57

Interfaces

Presentation

For discrete signals

Slim electromechanical interface modules

ABR-2 electromechanical interface modules complement the ABR-1 range.


They are characterised by micro relay technology which allows reduced dimensions
and very low switching levels (TTL, HCMOS, analogue signals).
The ABR-2 family is in the form of slim compact modules, 9.5 mm wide for input
interface modules, 12 mm wide for output interface modules and 17.5 mm wide for
very low level switching products.

Description

The ABR-2 comprises 3 families :


Input interfaces (9.5 mm pitch)
Input interfaces are designed for switching input signals to a processor and are
characterized by their high degree of contact reliability : less than 1 fault per
100million operating cycles at c 17 V, 5 mA.
An assured immunity to current leakages 2 mA, and a wide coil voltage range
(0.7to 1.25 Un).

1
2

5
3

Output interfaces (12 mm pitch)


Output interfaces are designed for the control of preactuators (contactors, solenoid
valves, etc) for signalling devices (indicators lamps, audible warnings etc). They are
characterized by a high switching capacity and an assured immunity to current
leakages
2 mA. A lower cost version without LED signalling is available.
Low level switching input and output interfaces (17.5 mm pitch)
with 1 C/O contact.
These interfaces are designed for switching logic (TTL or HCMOS) and analogue
signals.
Warning : never switch inductive loads with this type of interface.
The front panel of the ABR-2 electromechanical interface module comprises :
1 LED indicating the control signal state
2 Channel identification : 5 individual characters for AB1-R/G or 1 AB1-SA2
markertag
3 Connection by screw clamp terminal enabling easy attachment of 2 wires per
terminal. The layout of the connection terminals for both families (input and output)
is designed for rational wiring and a clear separation between the incoming
(processing) and outgoing (power and process control) circuits.

1
2

7
ABR-2SB312B

ABR2SB312B-PRO-3-B

9
10
Presentation:
page 58

58

Characteristics:
page 59

Curves:
page 61

References:
page 62

Dimensions, schemes:
page 63

Interfaces

Characteristics

For discrete signals

Slim electromechanical interface modules

Examples of applications with PLCs


PLC
Positive logic discrete inputs

PLC
Positive logic transistor (or relay) outputs

Processing
power
supply
+/

PLC
Analogue inputs

Channel X

A2

2
3

11

A1
14

12

A2
14

A1
13

A2
14

A1

14
A2

13

13
A1

A2

14
A2

14

13
A1

A1

14
A2

OV

13

13
A1

+
Process
power
supply

+/

C1

(1)

(1)
Pushbuttons
Series contacts

2-wire
sensors

3-wire
sensors

ABR 2Epppp

ABR 2Spppp

(1) Essential on inductive loads (can be replaced with peak limiter

C2
Analogue
sensors

ABR 2SB12B

).

Environment
Conforming to standards
Product certifications
Degree of protection
Protective treatment
Flame resistance

Conforming to IEC 529


(protection against direct contact)
C

kV

TC
960
V0
30 gn
3 gn
8

Shock resistance
Vibration resistance
Resistance to electrostatic
discharges
Resistance to
electromagnetic fields
Resistance to rapid
transients

Conforming to IEC 68-2-27


Conforming to IEC 68-2-6
Conforming to IEC 801-2

Incandescent wire
Conforming to UL 94
Semi-sinusoidal waves 11ms
10150Hz
Level 3

Conforming to IEC 801-3

Level 3 ; 271000 MHz

V/m

10

Conforming to IEC 801-4


Level 3

Resistance to shock
waves

Conforming to IEC 947-1

On power supply
On I/O
Waveform
1.2/50 ms ; 0.5 J

Cross-sections which
may be connected

Flexible cable with no cable end


Flexible cable with cable end
Rigid cable

kV
kV
kV
kV
kV
mm2
mm2
mm2
C
C

2
1
0.5
1.5
2.5
0.62.5
0.342.5
0.274
Any
- 5+ 40
- 5+ 55

- 25+ 70 (2)

C
m

- 40+ 80
3000
II
2
Standard rails 5 1 4

Operating position
Ambient air temperature

Conforming to IEC 695-2-1

IEC 947-5-1
UL, CSA, BV, LROS, DNV
IP 20

1 or 2-wire
1 or 2-wire
1-wire

Unrestricted operation
Operation from 0.85...1.1 Us
(assigned voltage)
Operation restricted to Us
(assignedvoltage)
Storage

Operating altitude
Installation category
Conforming to IEC 947-1
Degree of pollution
Conforming to IEC 947-1
Mounting
(2) Leave space of 8 mm between ABR-2S1ppp for an ambient temperature 55 C

U < 50 V
U < 150 V
U < 300 V

6
7
8
9
10

59

Interfaces

Characteristics (continued)

For discrete signals

Slim electromechanical interface modules

Control circuit characteristics (40C ambient temperature)

1
2
3
4
5

Type of interface
Rated voltage (Us)

Current frequency
Energization threshold
Maximum operating voltage
Maximum drop-out voltage (Uo)
Maximum current (at Us)
Minimum holding current
Maximum dissipated power (at Us)

Hz
V
V
V
mA
mA
W
W
ms

50 Hz
60 Hz

Disappearance of voltage
maximum time up to which contact is maintained
Display of control circuit by LED
Built-in protection reversed polarity

ABR
ABR
ABR
2E112B 2E112E 2E115F
c 24
c 48
z
115127

50
16.9
37.3
93
28.8
57.6
140
3.8
8.5
25.4
19.5
11
14
2
2
2.5

0.66
0.45
0.52

1
1
10

ABR
2E116F
z
120...127
60
97
140
25.4
16
2.5

0.73
10

ABR
2E111M
a
230...240
50/60
186
264
48
15
2.5
0.54
0.77
10

ABR
ABR
ABR
2S112B 2S102B 2pB312B (1)
c 24
c 24
c 24

16.9
28.8
3.8
28
2

0.64
1

14.5
28.8
2
18
1.3

0.43
5

16.9
28.8
3.8
23
2

0.55
1

Yes
Yes

Yes

Yes

Yes
Yes

No
Yes

Yes
Yes

Yes
Yes

Yes

Contact characteristics (40C ambient temperature)

Type of interface
Composition
Maximum rated
Conforming to IEC 947-5-1
operating voltage
(Uemax)
Maximum switching voltage
Operating current frequency
Thermal current Ith
Conforming to IEC 947-1
Rated operating
Conforming to IEC 947-5-1
current (Ie)
Ue max
for 1 million operating
cycles
Conforming to IEC 947-5-1
Ue : c 24 V

aV
cV

AC12
AC14
AC15
DC12
DC13

Minimum switching current


Minimum switching voltage
Protection against
For Ik 1 kA (a) and 100 A (c)
short-circuits
Typeand value of recommended fuse

Low level contact


Number of faults
reliability (17 V, 5 mA)/ per n million operating cycles
ABR-2pB (30 mV, 10 A)

Maximum operating
Between energization of coil c
time
and closing of N/O contact
a
at Us (bounce included)
Between energization of coil and
opening of N/C contact
Between de-energization of coil c
and opening of N/O contact
a

aV
cV
Hz
A
A
A
A
A
A
mA
V

ABR 2Epppp
1 N/O
127
100

ABR 2S112B
1 N/O
230
120

ABR 2S102B
1 N/O
230
120

ABR 2pB312B (1)


1 C/O
48
48

140
250
250
125
150
150
50/60
50/60
50/60
1
5
5
1
3
3
0.5
1
1
0.5
1
1
1
1.7
1.7
1
1.5
1.5
1
5
5
5
5
5
Type : quick-blow fuse with high breaking capacity
2
6.3
6.3
1 per 100 million

60
60
50/60
0.05

0.01
0.01

ms
ms
ms

10
30

10

10

ms
ms
ms

6
30

12

ms
ms
ms

2
5
2

Hz
Hz

10
0.5
20

10
0.5
10

10
0.5
10

10

20

V
V
kV rms
kV rms
kV rms

300
250
2
2.5
0.75

300
250
4
2.5
1

300
250
4
2.5
1

300
250
1.5
2.5
1

0.4

Other characteristics

8
9

Between de-energization of coil and


closing of N/C contact
Maximum duration of bounce
No make before break Maximum make
On energization
guaranteed between
before break or break On de-energization
N/C and N/O contacts before make time
Maximum operating
At no-load
rate
At Ie
Mechanical durability
inmillions of operating cycles
Rated insulation
Conforming to IEC 947-1
voltage
Conforming to VDE 0110 group C
Insulation test voltage Coil circuit/contact circuits
for 1 min
Wired interface/earth
Between open contacts
(1) Do not switch inductive loads.

10
Presentation:
page 58

60

Characteristics:
page 59

Curves:
page 61

References:
page 62

Dimensions, schemes:
page 63

Interfaces

Curves

For discrete signals

Slim electromechanical interface modules

Electrical durability of contacts (ABR 2S)


Test conditions : in accordance with standard IEC 947-5-1 set up for rated control voltage.

a.c. loads
Operating cycles in millions

Operating cycles in millions

1
2
3
4

24 V
48 V
115 V
230 V

2
1

2
1

0
0

1
2
3
4

6
(A)

AC12 : control of resistive loads and isolated solid state


loads via optocoupler
cos j 0.9

0,5

1,5

2,5

3
(A)

AC14 : control of weak electro-magnetic loads of


electro-magnets y 72 VA
make : cos j = 0.3
break : cos j = 0.3
AC15 : control of electro-magnetic loads of
electro-magnets > 72 VA
make : cos j = 0.7
break : cos j = 0.4

d.c. loads
Operating cycles in millions

Operating cycles in millions

1 24 V
2 48 V
3 115 V

1
1

0
0

0,5

1,5

2,5

0,5

1,5

2,5

DC12 : control of resistive loads and isolated solid state


loads via optocoupler
L/R 1 ms

(A)

(A )

DC13 : control of electro-magnets


L/R 2 x (Ue x Ie) in ms.
Ue : rated operating voltage
Ie : rated operating current
(with a load protection diode)

9
10

61

Interfaces

References

For discrete signals

Slim electromechanical interface modules


Control circuit : a.c. or d.c.

816362

Input modules (9.5 mm pitch)


Indication

With LED

Composition

Control circuit

1 N/C

V
c 24

ABR 2E112B

kg
0.032

c 48

ABR 2E112E

0.032

a 115...127 (50 Hz)

ABR 2E115F

0.035

a 120...127 (60 Hz)

ABR 2E116F

0.035

a 230...240 (50/60 Hz) 5

ABR 2E111M

0.036

2
ABR 2E112B

Indication

Composition

Control circuit

Sold in Unit
lots of reference

Weight

Without

1 N/C

V
c 24

ABR 2S102B

kg
0.040

With LED

1 N/C

c 24

ABR 2S112B

0.041

Modules for very low level switching (17.5 mm pitch)

Indication

Composition

Control circuit
V

Reference

Weight
kg

1 C/O (1)

c 24

ABR 2EB312B

0.048

1 C/O (1)

c 24

ABR 2EB312B

0.048

Input
With LED

Output

ABR 2S112B

With LED

Flexible comb accessories

816364

Weight

Output modules (12 mm pitch)

816363

Sold in Unit
lots of reference

Description For common

Flexible
comb
modularity
8 x 1 mm2

Coil

ABR 2EB112B

Colour

White

Red

Blue

Distance
between
cableends
cm
12

Reference

Weight

ABF C08R12W

kg
0.020

ABF C08R02W

0.010

12

ABF C08R12R

0.020

ABF C08R02R

0.010

12

ABF C08R12B

0.020

ABF C08R02B

0.010

816365

(1) Do not switch inductive loads.

8
ABF C08Rppp

9
10
Presentation:
page 58

62

Characteristics:
page 59

Curves:
page 61

References:
page 62

Dimensions, schemes:
page 63

Interfaces

Dimensions,
schemes

For discrete signals

Slim electromechanical interface modules

Dimensions

ABR 2S1p2B

78

74

74

ABR 2E11pp

78

9,5

70,5

75

75

ABR 2SB312B

78

78

17,5

70,5

75

75

63

63

ABR 2E112B (c 24 V)

17,5

70,5

Circuit diagrams

13

74

74

ABR 2EB312B

12

70,5

ABR 2E112E (c 48 V)

ABR 2E11pF/M (a 115...240 V)

14

13

14

14

13

A2

A1

+A1

ABR 2pB312B (c 24 V)

A2

A2

+A1

ABR 2S112B (c 24 V)

A2

+A1

A2

ABR 2S102B (c 24 V)

+A1

A2

+A1

8
14

13

14

13

11

12
14

9
10

63

Interfaces

Presentation

For discrete signals

Slim solid-state interface modules

The ABS-2 solid-state interface relays are supplied in the form of compact modules
which appear identical to the ABR-2 electromechanical family.
They are designed for interfacing discrete digital control signals exchanged within an
automated system between the processor (PLC, numerical controller, etc) and the
other components (contactors, solenoid valves, indicator lamps, proximity sensors,
etc).
They are suitable for use in equipment which requires the benefits of electronic
technology : a high operating rate, virtually unlimited durability, silent operation, etc.
These products are notable for their high performance and excellent adaptation to
industrial environments, ensured by the fact that they conform to the most recent IEC
standards.

1
2
816380

Composition

Input interfaces
The 9.5 mm wide input interfaces are designed for switching input signals to
processors. They offer a wide choice of electrical isolation between signals due to
the wide range of input voltages from c 5 V to a 230 V.

3
2
1

816378

4
3

1
2

816379

6
7

The ABS-2 range comprises 2 families :

Output interfaces
Output interfaces are designed for the control of preactuators (contactors, solenoid
valves, etc) for the signalling devices (indicator lamps, audible warnings, etc).
Two widths are available, 9.5 and 17.5 mm, depending on the switched current.
The 17.5 mm version comprises a 9.5 mm interface and an integrated 8 mm spacer.
This device can, with its increased ventilation, switch high levels of currents.
The front panel of the ABS-2 slim solid-state interface modules comprises:
1 LED indicating the state of the control signal.
2 Channel identification : 5 individual characters for AB1-/G or one AB1-SA2 marker
tag.
3 Connection by screw clamp terminal enabling easy attachment of 2 wires per
terminal.
The layout of the connection terminals for both families (input and output) is
designed for rational wiring and a clear separation between the incoming
(processing) and outgoing (power and process control) circuits.
4 Integrated spacer.

3
ABS2INTERSORT-PRO-3-B
1
2
4

8
9

ABS-2

ABS2-PRO-3-B

10
Presentation:
page 64

64

Characteristics:
page 65

Curves:
page 68

References:
page 68

Dimensions, schemes:
page 69

Interfaces

Characteristics

For discrete signals

Slim solid-state interface modules

Examples of applications with PLCs


Interfacing PLC discrete inputs
PLC
Positive logic discrete inputs

Processing
powersupply

13

13

13

13

A2

A1

A2

A1

A1

PNP

Pushbuttons
Series contacts

2-wire
3-wire
sensors sensors

14

13

14

Process
powersupply

13

13

A1

A2

A1

A2

A1

A2

A1

ABS - 2S

A2

A1

A2

13

ABS - 2E

A2

14

14

14

14

14

PLC
Positive logic transistor (or relay) outputs

14

Interfacing PLC discrete outputs

115/
230 V
Pushbuttons
Series contacts

2-wire
sensors

Environment
Conforming to standards
Product certifications
Degree of protection
Protective treatment
Flame resistance

Conforming to IEC 529


(protection against direct contact)
C

kV

TC
960
V0
30 gn
5 gn
8

Shock resistance
Vibration resistance
Resistance to electrostatic
discharges
Resistance to
electromagnetic fields
Resistance to rapid
transients

Conforming to IEC 68-2-27


Conforming to IEC 68-2-6
Conforming to IEC 801-2

Incandescent wire
Conforming to UL 94
Semi-sinusoidal waves 11ms
10150Hz
Level 3

Conforming to IEC 801-3

Level 3 ; 271000 MHz

V/m

10

Conforming to IEC 801-4


Level 3

Resistance to shock
waves

Conforming to IEC 947-1

On power supply
On I/O
Waveform
1.2/50 ms ; 0.5 J

Cross-sections which
may be connected

Flexible cable with no cable end


Flexible cable with cable end
Rigid cable

kV
kV
kV
kV
kV
mm2
mm2
mm2

2
1
0.5
1.5
2.5
0.62.5
0.342.5
0.274
Any
- 5+ 55
- 25+ 70
- 40+ 80
300
II
2
Standard rails 5 1 4

Operating position
Ambient air temperature
around the device
Operating altitude
Installation category
Degree of pollution
Mounting

Conforming to IEC 695-2-1

Unrestricted operation
Operation at Us
Storage
Conforming to IEC 947-1
Conforming to IEC 947-1

IEC 947-5-1
Draft standard IEC 17 B secretariat200
UL, CSA, BV, LROS, DNV
IP 20

1 or 2-wire
1 or 2-wire
1-wire

U < 50 V
U < 150 V
U < 300 V

C
C
C
m

6
7
8
9
10

65

Interfaces

Characteristics (continued)

For discrete signals

Slim solid-state interface modules

Control circuit characteristics (55C ambient temperature)

1
2

Type of interface
Rated voltage Us

c
a

V
V

Maximum voltage

a
c
a
c

V
mA
mA
V
mA
V
mA
V
mA
V
mA

Maximum current at Us
State 1 assured

State 0 assured

c
a

State 1 display
Internal protection reversed polarity

4
5

Output circuit characteristics

Rated operating voltage Ue


Min/max voltage
Min/max current switched
Maximum residual current at state 0
Maximum volt drop at state 1
Internal protection
External protection

c
c

V
V
mA
mA
V

ABS
2EC01EB
24

ABS
2EC01EE
48

57.6

ABS
2EA01EF

115/127
50 Hz

ABS
2EA02EF

120/127
60 Hz

ABS
2EA01EM

230/240
50 Hz

ABS
2EA02EM

230/240
60 Hz

Negative
logic
6(TTL)

13.6

3.75
4.5

2
0.09

Yes
Yes

28.8

12

16.9
7.7

5.6
2

Yes
Yes

10.5

36
7.5

10.8
2

Yes
Yes

140

14

86.3
8.4

25.4
2.5
Yes

140

17

90
9.7

25.4
2.5
Yes

264

12.5

173
7.9

48
2.5
Yes

264

15

173
9.3

48
2.5
Yes

ABS
2EA02EF
10
20
25

ABS
2EA01EM
10
20
25

ABS
2EA02EM
10
20
25

5...48
2/60
1/50
0.1
1
Reversed polarity
Against short-circuits for Ik 100 A (c)
Quick-blow fuse, ref. : HA21 0.25 A or equivalent

Other characteristics
Type of interface

ABS
2EC01EA
5

Time delay characteristics


Response time max Ue 30 V Ie 5 mA
Maximum switching rate
Duty cycle 50 %
Ue 30 V Ie 5 mA
Rated insulation voltage
Insulation test voltage
for 1 minute

I/O
Wired interface/earth

0V1
1V0

ms
ms
Hz

ABS
2EC01EA
0.05
0.4
1000

ABS
2EC01EB
0.05
0.4
1000

ABS
2EC01EE
0.05
0.4
1000

ABS
2EA01EF
10
20
25

kVrms
kVrms

Conforming to IEC 947-1 : 300 V


Conforming to VDE 0110 : 250 V group C
4
2.5

8
9
10
Presentation:
page 64

66

Characteristics:
page 65

Curves:
page 68

References:
page 68

Dimensions, schemes:
page 69

Interfaces

Characteristics (continued)

For discrete signals

Slim solid-state interface modules

Control circuit characteristics (55C ambient temperature)


Type of interface
Rated voltage Us
Maximum voltage
Maximum current at Us
State 1 assured

State 0 assured

ABS 2SC01EB
24
28.8
12
16.9
7.7
5.6
2
Yes
Yes

ABS 2SC02EB

V
V
A

c 5...48
c 57.6
2

A
A
A
A
mA
mA
V

DC12
DC13
DC14

1
1
1.5

V
V/ms

Reversed polarity
Against short-circuits for Ik 1 kA (a) and 100 A (c)
Quick-blow fuse with high breaking capacity: 3.15 A

ms
ms
Hz
Hz
Hz
Hz

0.05
0.6
DC13
DC14

700

kVrms
kVrms

Conforming to IEC 947-1 : z 300 V


Conforming to VDE 0110 : 250 V group C
4
2.5

V
V
mA
V
mA
V
mA

State 1 display
Internal protection reversed polarity

ABS 2SA01MB
24
28.8
13.6
16.9
8.3
5.3
2
Yes
Yes

ABS 2SA02MB

c 5...48
c 57.6
3

a 24...240
a 264
2.3

a 24...240
a 264
3

2.5/2.2
2.5/2.2
0.6/0.6

AC12
1.9/0.5
AC13
1.6/0.5
AC14
1.6/0.5
AC15
1/0.5
10
2.5
3 (Ie 10 mA)
1.5 (Ie 100 mA)
50 peak
500

2.1/1.5
1.6/1.5
1.6/1.5
1/1

1
2

Output circuit characteristics

Rated operating voltage Ue


Maximum voltage
Maximum continuous current (Ith) (1)
at 40 C
Rated operating voltage (Ie)
Conforming to IEC 947-5-1
Single/touching product
at 55 C vertical position
Minimum current
Maximum residual current
Maximum volt drop

c/a
c/a

0 crossing voltage
Solid-state dV/dt
Internal protection
External protection

1.5/0.9
1.5/0.9
0.6/0.6

3
4
5

Other characteristics
Maximum response time
at Ie 10 mA
Maximum switching rate

0V1
1V0
At 55 C ; at Ie: module alone
dutycycle 40 %
On resistive load
duty cycle 50 %

Rated operating voltage


Rated Insulation voltage
for 1 minute

I/O
Wired interface/earth
(1) See temperature derating curves.

6
1

6
3

10 (50 Hz) ; 8 (60Hz)


10 (50 Hz) ; 8 (60Hz)
AC13
0.6
0.7
AC14
0.6
0.7
AC15
0.6
0.7
50

6
7
8
9
10

67

Interfaces

References,
curves

For discrete signals

Slim solid-state interface modules

Solid-state input modules


Width

Input circuit
Current Nominal voltage
V
5
c
24
48
115127 (50 Hz)
a
120127 (60 Hz)
230240 (50 Hz)
230240 (60 Hz)

Output circuit
Current Nominal voltage
V
c
548
c
548
c
548
c
548
c
548
c
548
c
548

Sold in Unit
lots of reference

17.5

Output circuit
Current Nominal voltage
A
V
c2
2448
a 2.3
24230
c3
2448
a3
24230

Sold in Unit
lots of reference

mm
9.5

Input circuit
Current Nominal voltage
V
24
c

mm
9.5

2
Solid-state output modules
Width

3
Accessories

24

ABS 2SC01EB d.c.

ABS 2SC01EB
ABS 2SA01MB
ABS 2SC02EB
ABS 2SA02MB

ABS 2SC02EB d.c.


Ie (A)

1/2

3/4

10

20

30

40

50 60 70
T C ambient

ABS 2SA01MB a.c.

3
4

10

20

30

40

50 60 70
T C ambient

ABS 2SA02MB a.c.

Ie (A)

Weight

Temperature derating curve for solid-state output modules Uc = Us = c 24 V

1/2

5
5
1
1

kg
0.029
0.029
0.029
0.032
0.032
0.033
0.033

ABS 2EC01EA
ABS 2EC01EB
ABS 2EC01EE
ABS 2EA01EF
ABS 2EA02EF
ABS 2EA01EM
ABS 2EA02EM

For connecting commons, use ABF C08ppp flexible combs (Please consult your customer care centre).

Ie (A)

5
5
5
5
5
5
5

Weight

Ie (A)

1/2
3

1/2

4
1

3/4

10

20

30

40

50 60 70
T C ambient

10

20

30

40

50 60 70
T C ambient

1 Vertical module alone or adjacent to modules with


low heat dissipation.

2 Horizontal module alone or adjacent to modules with


low heat dissipation.

3 Vertical module mounted with 2 modules with


identical heat dissipation on both sides.

4 Horizontal module mounted with 2 modules with


identical heat dissipation on both sides.

Presentation:
page 64

Curves:
page 68

9
10

68

Characteristics:
page 65

References:
page 68

Dimensions, schemes:
page 69

kg
0.034
0.034
0.043
0.044

Interfaces

Dimensions,
schemes

For discrete signals

Slim solid-state interface modules

Dimensions

ABS 2Sp02pp

74

74

ABS 2E/ABS 2Sp01pp

78

78

9,5

70,5

70,5

75

75

17,5

Circuit diagrams

Solid-state input modules

548 V

4
5
6

A2

A1

A2

A1

A2

+A1

13

14

ABS 2Epppp

14

ABS 2EApppp

+13

14

+13

ABS 2ECpppp

Solid-state output modules


5-24 V

5-24 V

5-24 V

5-24 V

A2

A1

A2

A1

A2

A1

A2

7
8
14

13

14

13

14

13

14

13

14

(1)

Resistive load

(1)
F

13

14

+13

ABS 2SA0pMB

ABS 2SC0pEB

A1

A2

ABS 2SA0pMB

+A1

A2

+A1

ABS 2SC0pEB

Inductive load

Resistive load

Inductive load

F: fuse DF1 SS133.2

10

(1) or peak limiter

69

Zelio Relay - Solid State Relays

Selection guide

SSR solid state relays

Applications

Panel mounted

PF526060-24-Q

1
2
3
Contact type

4
5
6
7

Control voltage ranges

90280 V

332 V

Operating voltages

24280 V,
48530 V,
48660 V

Type of switching

Zero voltage switching

Current

10, 25, 50, 75, 90, 125 A

Degree of protection

IP20

LED indication

Yes

Cooling

Thermal protection or with heat sink accessory

Solid state relay type

1 N/O SPST contact

Page

9
10

70

SSR P
76

PF526062-32-Q

PF526339-18-Q

5 rail mounted

2
3
1 N/O SPST contact
90280 V

90140 V

432 V

332 V

24280 V

Zero voltage switching

10, 20, 30 A

45 A

IP20

Yes

Built-in heat sink

SSR D

76

9
10

71

Zelio Relay - Solid State Relays

Presentation

SSR solid state relays

Presentation

The SSR solid state relay range comprises:


b relays for panel mounting: SSR P.
b relays for 5 rail mounting: SSR D.

Description

2
3
5

SSR P relays for panel mounting


1 2 x 4.5 holes for fixing.
2 Connection terminals.
3 Connection terminal screws.
4 Input indicator LED, green.
5 Thermal interface which must be via the back of the product.

2
3
4
6

SSR D relays for 5 rail mounting


1 Lugs for panel mounting.
2 Integrated heat sink.
3 Connection terminals.
4 Connection terminal screws.
5 Input indicator LED, green.
6 Bracket for mounting on 5 rail.

5
1

6
7
8
9
10
Presentation :
page 72

72

Characteristics :
page 73

References :
page 76

Dimensions :
page 77

Characteristics

Zelio Relay - Solid State Relays


SSR P solid state relays
Panel mounting

General characteristics

Product certifications

UL E258297, CSA 168986

Product marking
Ambient air temperature
around the device

- 40+ 80

Storage

- 40+ 125

Encapsulation

Thermally conductive epoxy

Degree of protection

IP20

Terminal screw torque


Relay type

e, IEC 60950
Operation

Nm
SCR output, Zero voltage switching

Inputs: 1.1
Outputs: 2.2
SSR PCDS10A1

SSR PCDS25A1

SSR PCDS50A1

Input specification
Control voltage range

cV

332

332

332

Minimum turn-on voltage

cV

Maximum turn-off voltage

cV

1.0

1.0

1.0

Typical input current

mA

10 at c 12 V

10 at c 12 V

10 at c 12 V

Output specification
Operating voltage

aV

24280

24280

24280

Load current range

0.15 10

0.1525

0.1550

Transient overvoltage

Vpk

600

600

600

Maximum surge current (16.6 ms)

Apk

120

250

625

Maximum On-state voltage drop at rated current

Vpk

1.6

1.6

1.6

Thermal resistance junction to case

C/W

1.48

1.02

0.63

Maximum It for fusing (8.3 ms)

Asec

60

260

1620

Maximum off-state leakage current at rated voltage

mA

1.0

1.0

1.0

Minimum off-sate dv/dt at maximum rated voltage

V/sec 500

500

500

Maximum turn-on time

Cycle

1/2

1/2

1/2

Maximum turn-off time

Cycle

1/2

1/2

1/2

SSR PCDS75A2

SSR PCDS90A3

SSR PCDS125A3

Relay type

SCR output, Zero voltage switching

4
5

Input specification
Control voltage range

cV

432

432

432

Minimum turn-on voltage

cV

Maximum turn-off voltage

cV

1.0

1.0

1.0

Typical input current

mA

15 at c 5 V

15 at c 5 V

15 at c 5 V

Operating voltage

aV

48530

48660

48660

Load current range

0.1575

0.1590

0.15125

Transient overvoltage

Vpk

1200

1200

1200

Maximum surge current (16.6 ms)

Apk

1000

1200

1750

Maximum On-state voltage drop at rated current

Vpk

1.6

1.6

1.7

Thermal resistance junction to case

C/W

0.31

0.28

0.22

Maximum It for fusing (8.3 ms)

Asec

4150

6000

12 700

Maximum off-state leakage current at rated voltage

mA

10

1.0

1.0

Minimum off-sate dv/dt at maximum rated voltage

V/sec 500

500

500

Maximum turn-on time

Cycle

1/2

1/2

1/2

Maximum turn-off time

Cycle

1/2

1/2

1/2

Output specification

7
8
9
10

73

Characteristics (continued)

Zelio Relay - Solid State Relays


SSR P solid state relays
Panel mounting

Relay type

1
2
3
4
5
6

SCR output, Zero voltage switching

SSR PP8S10A1

SSR PP8S25A1

SSR PP8S50A1

Input specification
Operating voltage

aV

90280

90280

90280

Minimum turn-on voltage

Vrms

90

90

90

Maximum turn-off voltage

Vrms

10

10

10

Typical input current

mA

2 at 120 Vrms

2 at 120 Vrms

2 at 120 Vrms

Output specification
Operating voltage

aV

24280

24280

24280

Load current range

0.0410

0.0425

0.0450

Transient overvoltage

Vpk

600

600

600

Maximum surge current (16.6 ms)

Apk

120

250

625

Maximum On-state voltage drop at rated current

Vpk

1.6

1.6

1.6

Thermal resistance junction to case

C/W

1.48

1.02

0.63

Maximum It for fusing (8.3 ms)

Asec

60

260

1620

Maximum off-state leakage current at rated voltage

mA

810

810

810

Minimum off-sate dv/dt at maximum rated voltage

V/sec 500

500

500

Maximum turn-on time

Cycle

1/2

1/2

1/2

Maximum turn-off time

Cycle

1/2

1/2

1/2

SSR PP8S75A2

SSR PP8S90A3

SSR PP8S125A3

Relay type

SCR output, Zero voltage switching

Input specification
Operating voltage

aV

90280

90280

90280

Minimum turn-on voltage

Vrms

90

90

90

Maximum turn-off voltage

Vrms

10

10

10

Typical input current

mA

2 at 120 Vrms

2 at 120 Vrms

2 at 120 Vrms

Operating voltage

aV

80530

48660

48660

Load current range

0.0475

0.0490

0.15125

Transient overvoltage

Vpk

1200

1200

1200

Maximum surge current (16.6 ms)

Apk

1000

1200

1750

Maximum On-state voltage drop at rated current

Vpk

1.7

1.7

1.7

Thermal resistance junction to case

C/W

0.31

0.28

0.22

Maximum It for fusing (8.3 ms)

Asec

4150

6000

12 700

Maximum off-state leakage current at rated voltage

mA

10

Minimum off-sate dv/dt at maximum rated voltage

V/sec 500

500

500

Maximum turn-on time

Cycle

1/2

1/2

1/2

Maximum turn-off time

Cycle

1/2

1/2

1/2

Output specification

7
8
9
10
Presentation :
page 72

74

Characteristics :
page 73

References :
page 76

Dimensions :
page 77

Characteristics

Zelio Relay - Solid State Relays


SSRD solid state relay
5 rail mounting

General characteristics

Product certifications

UL E258297, CSA 168986

Product marking
Ambient air temperature
around the device

Storage

Encapsulation

Relay type

- 40+ 80
- 40+ 125
Thermally conductive epoxy

Degree of protection
Terminal screw torque

e, IEC 60950
Operation

IP20
1030 A relays

Nm

Inputs: 0.60.7
Outputs: 0.60.7

45 A relays

Nm

Inputs: 0.60.7
Outputs: 1.11.7

SCR output, Zero voltage switching

SSRDP8S10A1

SSRDP8S20A1

SSRDP8S30A1

SSRDF8S45A1

Input specification
Operating voltage

aV

90280

90280

90280

90140

Minimum turn-on voltage

Vrms

90

90

90

90

Maximum turn-off voltage

Vrms

10

10

10

10

Typical input current

mA

2 (120 Vrms),
4 (240 Vrms)

2 (120 Vrms),
4 (240 Vrms)

2 (120 Vrms),
4 (240 Vrms)

15 (120 Vrms)

Operating voltage

aV

24280

24280

24280

24280

Load current range

0.1510

0.1520

0.1530

0.1545

Transient overvoltage

Vpk

600

600

600

600

Maximum surge current (16.6 ms)

Apk

120

250

625

625

Maximum On-state voltage drop at rated current

Vpk

1.6

1.6

1.6

1.6

Maximum It for fusing (8.3 ms)

Asec

60

260

1620

1620

Maximum off-state leakage current at rated voltage

mA

10

10

10

10

Minimum off-sate dv/dt at maximum rated voltage

V/sec 500

500

500

500

Maximum turn-on time

Cycle

1/2

1/2

1/2

1/2

Maximum turn-off time

Cycle

1/2

1/2

1/2

1/2

SSRDCDS10A1

SSRDCDS20A1

SSRDCDS30A1

SSRDCDS45A1

Output specification

Relay type

SCR output, Zero voltage switching

4
5

Input specification
Control voltage range

cV

432

432

432

332

Minimum turn-on voltage

cV

4.0

4.0

4.0

4.0

Maximum turn-off voltage

cV

1.0

1.0

1.0

1.0

Typical input current

mA

812

812

812

17

Operating voltage

aV

24280

24280

24280

24280

Load current range

0.1510

0.1520

0.1530

0.1545

Transient overvoltage

Vpk

600

600

600

600

Maximum surge current (16.6 ms)

Apk

120

250

625

625

Maximum On-state voltage drop at rated current

Vpk

1.6

1.6

1.6

1.6

Maximum It for fusing (8.3 ms)

Asec

60

260

1620

1620

Maximum off-state leakage current at rated voltage

mA

10

10

10

10

Minimum off-sate dv/dt at maximum rated voltage

V/sec 500

500

500

500

Maximum turn-on time

Cycle

1/2

1/2

1/2

1/2

Maximum turn-off time

Cycle

1/2

1/2

1/2

1/2

Output specification

7
8
9
10

75

Zelio Relay - Solid State Relays

References

SSR solid state relays

Solid state relays, 1 N/O SPST contact


b Panel mounting

PF526060-24-Q

Switching

Voltage range
Input

Output

Load
current
range

References

Weight

c 332

a 24280

10

SSR PCDS10A1

0.113

25

SSR PCDS25A1

0.113

50

SSR PCDS50A1

0.113

a 48530

75

SSR PCDS75A2

0.113

a 48660

90

SSR PCDS90A3

0.113

125

SSR PCDS125A3

0.113

10

SSRPP8S10A1

0.113

25

SSRPP8S25A1

0.113

50

SSRPP8S10A1

0.113

a 80530

75

SSRPP8S75A2

0.113

a 48660

90

SSRPP8S90A3

0.113

125

SSRPP8S125A3

0.113

10

SSRDP8S10A1

0.272

20

SSRDP8S20A1

0.272

30

SSRDP8S30A1

0.272

kg

SCR output
Zero voltage
switching

c 432

PF526339-18-Q

SSR PCDS25A1

a 90280

4
SSRDCDS10A1

b 5 rail mounting

PF526062-32-Q

SCR output
Zero voltage
switching

6
7

a 90280

a 24280

45

SSRDF8S45A1

0.482

c 432

a 24280

10

SSRDCDS10A1

0.272

20

SSRDCDS20A1

0.272

30

SSRDCDS30A1

0.272

45

SSRDCDS45A1

0.482

SSRDCDS45A1

PF526063-50-Q

a 24280

Accessories for panel mounted relays


Description

For use with relays

Unit references

Heat sink

SSRPP8Spppp,
SSRPCDSpppp

SSRAH1

0.487

Thermal interface
Sold in lots of 10

SSRPP8Spppp,
SSRPCDSpppp

SSRAT1

0.011

PF526064-28-Q

SSRAH1

a 24280

a 90140

c 332

a 24280

10
SSRAT1
Presentation :
page 72

76

Characteristics :
page 73

References :
page 76

Dimensions :
page 77

Weight
kg

Zelio Relay - Solid State Relays

Dimensions

SSR solid state relays

Solid state relays, 1 N/O SPST contact


b Panel mounting

Solid state relays SSR P

47,7
55,1

58,4

4,5

47,3
35,5

Thermal interface SSRAT1


45,5

4,6

42,4

47,1

3
66

Heat sink SSRAH1

4
4,6

115,8

4,6
114,3

120,6

139,7

b 5 rail mounting
1030 A relays

45 A relays
4,4

4,4

87,4

76,2

98,8

80

89,7

98,8

6
(1)

11,2

(1)

13,15

22,5

7
22,6
45,5

97,7
106,7
(1) 4.4 x 5.5 elongated hole

(1) 4.4 x 5.5 elongated hole

9
10

77

Head office
35, rue Joseph Monier
92500 Rueil-Malmaison
France

www.schneider-electric.com
The information provided in this documentation contains general descriptions and/or technical
characteristics of the performance of the products contained herein. This documentation is not
intended as a substitute for and is not to be used for determining suitability or reliability of these
products for specific user applications. It is the duty of any such user or integrator to perform the
appropriate and complete risk analysis, evaluation and testing of the products with respect to the
relevant specific application or use thereof. Neither Schneider Electric nor any of its affiliates or
subsidiaries shall be responsible or liable for misuse of the information contained herein.
Design: blueloft.fr
Photos: Schneider Electric
Printed by: Schneider Electric

ART. 960361

DIA3ED2090304EN

Schneider Electric Industries SAS

Potrebbero piacerti anche