Keyboard Usage
Up Arrow: Increases by one parameter value or navigates forward between
menu options.
Down Arrow: Decreases by one parameter value or navigates backward
between menu options.
Right Arrow: Change sign for +/- values
Left Arrow: Delete last digit of value being edited
ESC: Exit parameter o menu
Enter: Select option or save parameter
0 9: Only available while editing a parameter field, to enter parameter
value.
F1: Configuration Menu. General parameters setup.
TEST: JOG, request one label from printer.
F2: Not Used
F3: Not Used
CALIB: Not Used
F4: Not Used
F5: Not Used
PROG: Selects active program. Range 0-30.
F6: Not Used
EDIT: Modifies the parameters associated to the currently selected
program.
F1 Configuration Menu
8- End of cycle
Range: 0-1
Unit: Default Value: 0
"DELAY BTW CYCLES"
Delay after label is dispensed before starting application cycle.
Range: 0-255
Unit: 10 milliseconds per unit (0 to 2550 milliseconds)
Default Value: 0
"CYCLE END DELAY "
Delay prior to starting next label cycle. This delay allows tamp to
return to home position. If HOME sensor is connected, this parameter is
a timeout value (maximum time to before tamp is considered to be home).
Range: 0-255
Unit: 30 milliseconds per unit (0 to 7650 milliseconds)
Default Value: 0
"ASSIST DELAY ON "
Length of dispensed label before Assist valve is activated.
Range: 0-255
Unit: milliseconds
Default Value: 50
"ASSIST DELAY OFF"
Delay in milliseconds after label stops feeding prior to deactivating
assist valve.
Range: 0-255
Unit: milliseconds
Default Value: 0
"LOW LABEL LOGIC"
"
0=NO 1=NC "
Optional low level sensor for labels. 0=Normally Open sensor, 1= Normally
closed sensor.
Range: 0-1
Unit: Default Value: 1
"* FIRMWARE VER *"
Software Version. This is a read only parameter.
"*** KPA 400 ***"
"V2.2. AUG/30/06"
TIME"
"T/B
DWELL
Tamp o Blow activation time. Time during which the electro valve remains
activated. If END sensor is connected, this parameter is a timeout
value (maximum activation time).
Range: 0-10000
Unit: milliseconds
Default Value: 0
"2nd BLOW DWELL T"( Cilindros detenimiento Cajas)
Option available if MODE set to 3=T+B.
Blow after Tamp activation time. Time during which the electro valve
remains activated. Activation occurs immediately after Tamp is
deactivated if T+B mode is set to AFT, if T+B mode is set to SIM, Tamp if
deactivated when blow time ends.
Range: 0-10000
Unit: Tens of milliseconds
Default Value: 0
" PRODUCT DELAY "
Time between product being detected and start of new cycle.
Range: 0-10000
Unit: milliseconds
Default Value: 0
Diagnostic Menu
Press TEST key during power up to enter this menu.
" TAMP END SENSOR "
Shows in real time the state of the End sensor of the tamp cylinder.
Press ENTER to access this option. To exit press ENTER or ESC. ON is
active, OFF is inactive.
"END=OFF"
" TRIGGER INPUT "
Shows in real time the state of the start of cycle input. Press ENTER to
access this option. To exit press ENTER or ESC. 1 is active, 0 is
inactive.
" PRODUCT SENSOR "
"VALUE = 1
"
" REWINDER OUTPUT "
Allows manual activation and deactivation of the rewind motor.
Use UP & DOWN arrows to toggle the output state.
To exit press ENTER or ESC.
" REWIND OUTPUT ON"
" TOGGLE W/UP&DWN "
" TAMP/BLOW OUTPUT"
Allows manual activation and deactivation of the Tamp or Blow
electrovalve. Press ENTER to access this option. To exit press ENTER or
ESC. ON is active, OFF is inactive. Use UP & DOWN arrows to toggle the
output state.
" T/B OUTPUT
ON"
" TOGGLE W/UP&DWN "
"ASSIST
OUTPUT"
Allows manual activation and deactivation of the Assist electrovalve.
Press ENTER to access this option. To exit press ENTER or ESC. ON is
active, OFF is inactive. Use UP & DOWN arrows to toggle the output state.
"ASSIST OUTPUT ON"
" TOGGLE W/UP&DWN "
"VENTURI
OUTPUT"
Allows manual activation and deactivation of the Venturi electrovalve,
this hardware is optional. Press ENTER to access this option. To exit
press ENTER or ESC. ON is active, OFF is inactive. Use UP & DOWN arrows
to toggle the output state.
"VENTURI OUTPT ON"
" TOGGLE W/UP&DWN "
"2nd BLOW OUTPUT"
Allows manual activation and deactivation of the second blow
electrovalve, this hardware is optional. Press ENTER to access this
option. To exit press ENTER or ESC. ON is active, OFF is inactive. Use UP
& DOWN arrows to toggle the output state.
" 2nd BLOW OUTP ON "
" TOGGLE W/UP&DWN "
" START PRINT OUT "
Allows manual activation and deactivation of print trigger output. Press
ENTER to access this option. To exit press ENTER or ESC. ON is active,
OFF is inactive. Use UP & DOWN arrows to toggle the output state.
Start of Print signal enables the printer to print a new label. Printer
must be configured in applicator mode with the right signal mode (e.g.
MODE 2 for Zebra) and the printer must have labels in its buffer.
" START PRINT
ON"
" TOGGLE W/UP&DWN "
" PRINTER OUTPUTS"
Shows in real time printers outputs for Ribbon Low (RL), Service
Required (SR) and End of Print (EP). This signals are used by the KPA
controller to command the rewind motor, assist valve and alarms.
" RL=1 SR=0 EP=1"
Press ESC to exit diagnostics menu.