Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Coating plants
Combined booths
Safety requirements
ICS 87.100
12&23<,1*:,7+287%6,3(50,66,21(;&(37$63(50,77('%<&23<5,*+7/$:
BS EN
13355:2004
BS EN 13355:2004+A1:2009
National foreword
This British Standard is the UK implementation of EN 13355:2004+A1:2009.
It supersedes BS EN 13355:2004, which is withdrawn.
The start and finish of text introduced or altered by amendment is indicated
in the text by tags. Tags indicating changes to CEN text carry the number of
the CEN amendment. For example, text altered by CEN amendment A1 is
indicated by .
Comments
31 May 2009
EUROPEAN STANDARD
EN 13355:2004+A1
NORME EUROPENNE
EUROPISCHE NORM
April 2009
ICS 87.100
Supersedes EN 13355:2004
English Version
This European Standard was approved by CEN on 22 November 2004 and includes Amendment 1 approved by CEN on 22 February 2009.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up to date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the
official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
2009 CEN
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
Contents
Page
Foreword ...................................................................................................................................................................... 4
Introduction ................................................................................................................................................................. 5
1
Scope .............................................................................................................................................................. 6
2
3
4
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
5
5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
5.10
6
6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.8
6.9
6.10
7
7.1
7.2
7.3
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
B.1
B.2
Annex C (informative) Classification of materials reaction to the fire National standards ........................... 41
Annex D (informative) References to national exposure limit values ................................................................. 42
Annex E (informative) Equivalence between zone description and categories of ignition protection ............ 43
Annex ZA (informative) Relationship between this European Standard and the Essential Requirements
of EU Directive 98/37/EC !, amended by 98/79/EC" .......................................................................... 44
Annex ZB (informative) !Relationship between this European Standard and the Essential
Requirements of EU Directive 2006/42/EC"........................................................................................... 45
Bibliography .............................................................................................................................................................. 46
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
Foreword
This document (EN 13355:2004+A1:2009) has been prepared by Technical Committee CEN/TC 271 Surface
treatment equipment Safety, the secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an identical text or
by endorsement, at the latest by October 2009, and conflicting national standards shall be withdrawn at the latest
by December 2009.
This document has been prepared under a mandate given to CEN by the European Commission and the European
Free Trade Association, and supports essential requirements of EU Directive(s) 98/37/EC and 94/9/EC.
!For relationship with EU Directive(s), see informative Annexes ZA and ZB, which are integral parts of this
document."
This document includes Amendment 1, approved by CEN on 2009-02-22.
This document supersedes EN 13355:2004.
The start and finish of text introduced or altered by amendment is indicated in the text by tags ! ".
This document is part of a series of standards in the area of safety for development and construction of machines
and plants for the coating of surfaces with organic substances (paints, varnishes and similar products).
This document is mainly based on EN 12215 and EN 1539.
NOTE
Although a spray booth, as an integral whole, formally does not fall under the scope of the ATEX Directive 94/9/EC,
the document is based upon a fundamental risk analysis according to this directive.
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden,
Switzerland and United Kingdom.
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
Introduction
This document is a C-type standard as stated in EN ISO 12100.
The machinery concerned and the extent to which hazards, hazardous situations and events are covered are
indicated in the scope of this document.
When provisions of this type C standard are different from those which are stated in type A or B standards, the
provisions of this type C standard take precedence over the provisions of the other standards, for machines that
have been designed and built according to the provisions of this type C standard.
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
Scope
This document is applicable to combined booths for the application of organic liquid coating materials by an
operator with maximum drying temperature of 100 C and deals with all hazards significant for combined booths,
when they are used as intended and under the conditions foreseen by the manufacturer (see clause 4).
To the extent of this document, a combined booth is considered an assembly of the following equipment:
control and power circuits joined together for the spraying and drying process of liquid coating material in a
space totally enclosed provided with forced ventilation.
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
Normative references
The following referenced documents are indispensable for the application of this document. For dated references,
only the edition cited applies. For undated references, the latest edition of the referenced document (including any
amendments) applies.
EN 418, Safety of machinery Emergency stop equipment, functional aspects Principles for design
EN 525, Non-domestic direct gas-fired forced convection air heaters for space heating not exceeding a net heat input
of 300 kW
EN 563, Safety of machinery Temperatures of touchable surfaces Ergonomics data to establish temperature
limit values for hot surfaces
EN 746-1, Industrial thermoprocessing equipment Part 1: Common safety requirements for industrial
thermoprocessing equipment
EN 746-2, Industrial thermoprocessing equipment Part 2: Safety requirements for combustion and fuel handling
systems
EN 954-1, Safety of machinery Safety related parts of control systems Part 1: General principles for design
EN 971-1:1996, Paints and varnishes Terms and definitions for coating materials Part 1: General terms
EN 981, Safety of machinery System of auditory and visual danger and information signals
EN 982, Safety of machinery Safety requirements for fluid power systems and their components Hydraulics
EN 983, Safety of machinery Safety requirements for fluid power systems and their components Pneumatics
EN 1037, Safety of machinery Prevention of unexpected start-up
EN 1088, Safety of machinery Interlocking devices associated with guards Principles for design and selection
EN 1127-1:1997, Explosive atmospheres Explosion prevention and protection Part 1: Basic concepts and
methodology
EN 1539:2000; Dryers and ovens, in which flammable substances are released Safety requirements
EN 1953, Atomising and spraying equipment for coating materials Safety requirements
!EN 12753", Thermal cleaning systems for exhaust gas from surface treatment equipment Safety
requirements
EN 12433-1, Industrial, commercial and garage doors and gates Terminology Part 1: Types of doors
EN 12433-2, Industrial, commercial and garage doors and gates Terminology Part 2: Parts of doors
EN 12445, Industrial, commercial and garage doors and gates Safety in use of power operated doors Test
methods
EN 12453, Industrial, commercial and garage doors and gates Safety in use of power operated doors
Requirements
EN 12635, Industrial, commercial and garage doors and gates Installation and use
EN 12978, Industrial, commercial and garage doors and gates Safety devices for power operated doors and gates
Requirements and test methods
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
EN 13463-1:2001, Non-electrical equipment for potentially explosive atmospheres Part 1: Basic method and
requirements
EN 13463-5, Non-electrical equipment intended for use in potentially explosive atmospheres Part 5: Protection by
constructional safety "c"
EN 13478, Safety of machinery Fire prevention and protection
!EN 14462:2005, Surface treatment equipment Noise test code for surface treatment equipment including its
ancillary handling equipment Accuracy grades 2 and 3"
!EN 14986", Design of fans working in potentially explosive atmospheres
EN 60079-0, Electrical apparatus for explosive gas atmospheres Part 0: General requirements (IEC 60079-0:2004)
EN 60079-15, Electrical apparatus for explosive gas atmospheres Part 15: Type of protection n
(IEC 60079-15:2001, modified)
EN 60204-1:1997, Safety of machinery Electrical equipment of machines Part 1: General requirements
(IEC 60204-1:1997)
EN 60529, Degrees of protection provided by enclosures (IP code)
EN 61000-6-1, Electromagnetic compatibility (EMC) Part 6-1: Generic standards; Immunity for residential,
commercial and light-industrial environments (IEC 61000-6-1:1997, modified)
EN 61000-6-3, Electromagnetic compatibility (EMC) Part 6-3: Generic standards; Emission standard for residential,
commercial and light-industrial environments (IEC 61000-6-3:1996, modified)
EN 61000-6-4, Electromagnetic compatibility (EMC) Part 6-4: Generic standards; Emission standard for industrial
environments (IEC 61000-6-4:1997, modified)
EN ISO 3746, Acoustics Determination of sound power levels of noise sources using sound pressure Survey
method using an enveloping measurement surface over a reflecting plane (ISO 3746:1995)
EN ISO 4871, Acoustics Declaration and verification of noise emission values of machinery and equipment
(ISO 4871:1996)
EN ISO 11202, Acoustics Noise emitted by machinery and equipment Measurement of emission sound
pressure levels at a work station and at other specified positions Survey method in situ (ISO 11202:1995)
EN ISO 12100-1, Safety of machinery Basic concepts, general principles for design Part 1: Basic terminology,
methodology (ISO 12100-1:2003)
EN ISO 12100-2:2003, Safety of machinery Basic concepts, general principles for design Part 2: Technical
principles (ISO 12100-2:2003)
EN ISO 14122-2, Safety of machinery Permanent means of access to machinery Part 2: Working platforms and
walkways (ISO 14122-2:2001)
EN ISO 14122-3, Safety of machinery Permanent means of access to machinery Part 3: Stairs, stepladders and
guard-rails (ISO 14122-3:2001)
EN ISO 14122-4, Safety of machinery Permanent means of access to machinery Part 4: Fixed ladders
(ISO 14122-4:2004)
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
For the purpose of this document, the terms and definitions given in EN 12100-1:2003 and the following apply.
3.1
combined booth
assembly of linked components such as fan(s), ventilation air heating system (e. g. heat exchanger or burner),
power driven dampers, forced ventilation ducting, dry air filtering and/or wet air washing systems, automatic fire
extinguishing equipment and additional specific electrical equipment, control and power circuits joined together for
the spraying and drying process of liquid coating material in a space totally enclosed provided with a forced
ventilation
3.2
working pit
ground excavation, illuminated and ventilated in which the operator works while painting the underside of an item
3.3
organic liquid coating material
organic product, in liquid form, that when applied to a substrate forms a film possessing protective, decorative
and/or specific technical properties, e.g.: paints, varnishes, including their solvents and thinners (see EN 971-1)
3.4
solvent
single liquid, or blends of liquid, volatile under specified drying conditions, and in which the binder is completely
soluble (see 1.4.5 of EN 971-1:1996)
NOTE
3.5
spraying
application of coating material on an item within the combined booth by pneumatic, airless, electrostatic or
combination of these spraying systems
3.6
drying
evaporation of liquids from the materials being processed (see 3.5 of EN 1539:2000).
3.7
curing
Transformation of a liquid, paste or powder coating material into a finished solid material (see 3.8 of EN 1539:2000)
NOTE
3.8
forced ventilation
air circulation achieved by one or several fans
3.9
recirculated air
air extracted from the volume and reintroduced into it
3.10
air cleaning (filtering system)
Filtering system used for introducing clean air into the booth and cleaning contaminated air extracted from the
combined booth
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
3.11
flammable (combustible) substances
substance in the form of gas, vapour, liquid, solid or mixtures of these, able to undergo an exothermic reaction with
air when ignited (see 3.1 of EN 1127-1:1997)
NOTE
"Combustible materials" and "flammable substances" are equivalently used terms in this standard. Examples are
paint aerosols and solvents.
3.12
explosive atmosphere
mixture with air, under atmospheric conditions, of flammable substance(s) in the form of gas, vapour, mist or dust,
in which after ignition has occurred, combustion spreads to the entire unburned mixture (see EN 1127-1)
3.13
lower explosion limit (LEL)
lower limit of the range of concentration of a combustible in air over which an explosion can occur (3.8 and 3.13 of
EN 1127-1:1997)
NOTE
Explosion limit and Ignition limit are equivalent. In accordance with international usage, only the term explosion
limit" is used in this standard.
3.14
total space
net volume within the booth during spraying and drying processes which may contain released substances. It
includes all sections of the combined booth recirculation system(s) and ends at the outlet connection to the external
exhaust
NOTE
It does not include any items loaded into the combined booth, supports, transport systems or thermal cleaning
systems (see !EN 12753").
3.15
hazardous areas
areas where hazards due to explosive atmosphere may exist. The probability of occurrence of explosive
atmosphere is classified in zones
3.15.1
zone 0
place in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas,
vapour or mist is present continuously or for long periods or frequently (see 6.3.2 of EN 1127-1:1997)
3.15.2
zone 1
place in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas,
vapour or mist is likely to occur in normal operation occasionally (see 6.3.2 of EN 1127-1:1997)
3.15.3
zone 2
place in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas,
vapour or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only (see
6.3.2 of EN 1127-1:1997)
3.16
Equipment category
3.16.1
Equipment Group II Category 1
equipment in this category is intended for use in areas in which explosive atmospheres caused by mixtures of air
and gases, vapours or mists are present continuously for long periods or frequently (see 3.2.3 of EN 13463-1:2001)
NOTE
10
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
3.16.2
Equipment Group II Category 2
equipment in this category is intended for use in areas in which explosive atmospheres caused by mixtures of air
and gases, vapours or mists are likely to occur (see 3.2.4 of EN 13463-1:2001)
NOTE
3.16.3
Equipment Group II Category 3
equipment in this category is intended for use in areas in which explosive atmospheres caused by mixtures of air
and gases, vapours or mists are unlikely to occur, or, if they do occur, are likely to do so only in frequently and for a
short period only (see 3.2.5 of EN 13463-1:2001)
NOTE
3.17
exposure limits
concentration limits of hazardous substances in air required by worker health legislation
NOTE
3.18
maximum drying temperature
upper limit of circulated air temperature within the working area for which the combined booth is designed
3.19
ventilation air heating system
heat generating and air heat exchanger system direct or indirect, which may include burner, combustion chamber,
heat exchanger, fan(s), inlet, exhaust and recirculation ducts, enclosures and ancillaries, measuring and control
devices
4.1
General
This clause contains all the significant hazards, hazardous situations and events as far as they are dealt with in this
standard, identified by risk assessment as significant for this type of machinery and which require action to
eliminate or reduce the risk.
All hazards generated by spraying equipment for liquid paint and varnish and their ancillary devices are covered by
EN 1953.
NOTE
4.2
Mechanical hazards
4.2.1
fans (e.g. injuries caused by after-running of fan blades) and air change valves for the combined booth
11
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
4.2.2
Entrapment of operators
obstacles or obstructions which can impede evacuation from the combined booth including any working pit in
case of mechanical accident or the occurrence of fire;
accidental significant lowering of pressure inside the combined booth (i.e.: obstruction of air inlet) capable of
clamping the doors by mechanical deformation of the structure of the combined booth;
4.2.3
floor gratings;
slippery floors;
4.3
Electrical hazards
4.3.1
electrically live parts that are non insulated for operational reasons (for instance in electrostatic devices);
live parts when insulation is damaged by contact with solvents or by mechanical means.
4.3.2
4.4
interaction of the electrostatic high voltage equipment elements of the control and safety systems which can
cause dangerous malfunctions, e. g. short circuits on electronic safety circuits, entrance guards, alarm units.
Thermal hazards
4.5
These hazards are related to combined booths and can be present inside as well as outside the booth.
They can be generated by noises emitted for instance by:
fans;
12
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
air operated equipment ( nozzles of atomising and spraying equipment, pumps, valves...).
4.6
These hazards are related to the use of infra-red radiation (IR) causing
burning.
4.7
4.7.1 Contact with/or absorption of, fluids (paints, solvents, hydraulic and thermal fluid) which are dangerous to
health causing damage to the skin or eyes or dermatitis or allergies.
4.7.2
Inhalation of aerosols and solvent vapours released by organic liquid coating materials.
4.7.3
Inhalation of toxic gases released from the heating device (e.g. heating and combustion gases).
4.7.4
4.8
4.8.1
Fire hazards
Fire hazards are related to combustible or flammable substances coming in contact with ore are ignited by:
electrical sparks;
NOTE
Explosion hazards
Explosion hazards are related to an increase of the concentration of flammable substances in air exceeding the
lower explosion limit (LEL) and coming in contact with or are ignited by
13
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
electrical sparks;
NOTE
4.9
Examples of flammable substances which increase concentration above the lower explosion limit:
petrol vapours.
Hazards caused by failure of the energy supply and malfunction of the control system
4.9.1
loss of lighting.
4.9.2
Hazards due to failure or malfunction of the control system (unexpected start-up) which can lead to:
wrong sequence of essential control functions resulting in a start of heating before forced ventilation is
activated;
malfunction of temperature monitoring devices resulting in a hazardous increase of the temperatures of the
heating system.
5
5.1
Machinery shall comply with the safety requirements and/or protective measures of this clause. In addition, the
machine shall be designed according to the principles of EN ISO 12100 for hazards relevant but not significant
which are not dealt with by this document (e.g. sharp edges).
NOTE
Hazards generated by spraying equipment for organic liquid coating materials and their ancillary devices are
covered by EN 1953.
14
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
5.2
Mechanical
5.2.1
The design shall avoid injury due to shearing, crushing or drawing-in by movement of machinery and/or parts of
equipment. Contact with dangerous moving parts shall be prevented by the following measures:
for doors, gates and hoods: (re)movable guards, hydraulically, pneumatically or electrically interlocked with the
hazardous movement or event.
!When fixed guards are applied, they shall be fixed by systems that can be opened or removed only with tools.
Their fixing systems shall remain attached to the guards or to the machinery when the guards are removed. Where
possible, these guards shall be designed in such a way that they can only remain in place using their fixing
system."
If automatic devices for spraying systems like robots or reciprocators or similar systems are installed, access to
dangerous areas requires doors or other protective devices (mechanical or light sensitive) interlocked with the
hazardous movement or event (see also 5.8.2.5).
NOTE
5.2.2
Entrapment of persons
Combined booths shall be designed so that in case of an emergency all persons entrapped can find their way out
of the combined booth in the quickest possible time, without being hindered by obstructions.
NOTE
Auxiliary use of robots or similar automatic devices is excluded from the scope (see scope, exclusions under d)).
shall be capable of being opened from inside by a mere push, independent of the air pressure (high or low)
within the combined booth,
shall be self-closing,
shall have a minimum 800 mm width and minimum 2000 mm height (free opening).
Combined booths shall be provided with a minimum of two permanently accessible and normally non-lockable
doors placed as far as practically possible apart from each other. Also when the booth is loaded the operator shall
not have more than 10m to travel in order to reach at least one of these doors.
If the booth-loading door can be opened by a mere push from the inside only one additional personnel door shall
be required.
If the longest wall is less than 5m a single door is considered to be sufficient.
Power-operated doors as well as vertical and horizontal sliding doors cannot be considered as personnel door.
Power-operated doors shall comply with EN 12433, EN 12445, EN 12453, EN 12635 and EN 12978.
In addition the length and width of combined booths shall be a minimum of 1m on each side than of the biggest
item to be painted.
15
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
5.2.3
Gratings, platforms and other surfaces likely to be walked upon shall be designed so as to minimise the risk of
slipping or falling.
Ladders, gangways and railings shall comply with EN ISO 14122-2, EN ISO 14122-3 and EN ISO 14122-4.
The grid sections, platforms or similar equipment shall be securely located within their housings, to avoid
movement and instability.
The combined booth shall be provided with adequate lighting, with 600 lux minimum.
5.3
Electrical
5.3.1
General
Electrical equipment
Protection against electrical shock shall comply with requirements of clause 6 of EN 60204-1:1997.
The insulation of electrical equipment shall be resistant against solvents and other fluids. Electrical equipment shall
be protected against outside mechanical influence.
All mechanical conductive parts shall be earthed (see EN 60204-1)
NOTE
EN 1953.
5.3.3
For spraying equipment, and ancillary equipment see EN 1953. For hand-held electrostatic guns see EN 50050 and
All systems and apparatus relevant for safety shall be constructed in such way that they cannot be influenced by
electromagnetic disturbances (see EN 61000-6-1, EN 61000-6-3, EN 61000-6-4).
5.4
Thermal
Protection against burns by hot surfaces shall be secured by means of appropriate insulation or protection against
contact of all elements within arms reach and within the working area. According to EN 563 at an ambient
temperature of 20 C the surface temperature shall be less than 60 C. Exceptions are permissible in small
localised areas of the surface (for example flanges of burners, bolts, fan and roller shaft).
NOTE
5.5
Noise
A combined booth shall be so designed and constructed that risks resulting from the emission of airborne noise are
reduced to the lowest level taking account of technical progress and the availability of means of reducing noise, in
particular at source.
The following measures can be adopted where possible:
flexible connections between the ducts and especially between fans and ducts;
16
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
ducts soundproofing;
means to avoid transmission to the structure of the combined booth, of vibrations, resonances and any other
noise generated by ancillary equipment that is permanently installed and connected to the booth.
NOTE 1
This list is not exhaustive. EN ISO 11688-1 gives general technical information on widely recognised technical rules
and means to design low-noise machinery.
NOTE 2
NOTE 3
For noise emitted by air compressors and spraying equipment see EN 1012-1 and EN 1953.
5.6
Radiation
Infra-red heating systems shall be designed and constructed to minimise any harmful effect of radiation.
The protection can be achieved by the following measures:
interlocking of all doors to shut down the heating system to prevent entry by personnel when the heaters are in
use
Additional warning signs shall be fitted on the outside of the doors (see 7.2.1).
5.7
5.7.1
Contact with or absorption of dangerous substances sprayed shall be reduced by forced ventilation as far as
possible (see 5.7.2). See also provisions for the information for use to be included in the instruction handbook
in 7.2.2.
5.7.2
5.7.2.1
In order to avoid inhalation of aerosols and solvent vapours the combined booth shall have an adequate forced
ventilation taking into account:
type of application,
exposure limit values relevant to the used coating material (examples given in annex !D").
5.7.2.2
Airflow
17
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
The airflow shall be as uniform as possible. Furthermore, the escape of air containing solvent vapours in hazardous
amounts or concentrations from the booth shall be prevented (e.g. preferably by maintaining a negative pressure
within the booth).
The airflow shall be directed in such a way that the operator is protected against inhalation of air contaminated by
organic liquid coating materials at dangerous levels.
For residual risks emanating from the hazards dealt with in this clause see 7.2.2.
5.7.2.3
Air velocity
Combined booths shall be designed for air velocities specified below for empty booth conditions as described in a),
b) and c):
a)
For combined booths for similar items (e.g.: small vehicles, vans) and combined booths for large similar items
(e.g.: buses, trucks):
c)
For combined booths with a working pit air velocities specified below shall be measured inside the working pit.
The average of measured air velocities inside the working pit shall be at least 0,30 m/s.
Single measured values inside the working pit shall be at least 0,25 m/s.
Corresponding measurement points are specified in annex B.
Special air velocities are acceptable for a combined booth where very long items are to be painted (e.g.: train
carriages, aeroplane), but the health and safety of the operator shall be ensured. The conditions for the health of
the operator inside the combined booth shall be evaluated by special risk assessment.
The use of personal breathing protective devices is required when spraying inside enclosures (e.g. train carriages,
trucks, busses or in a working pit within the booth, see clause 7.2.2).
5.7.2.4
Combined booths shall be provided with a device that is capable of monitoring air velocity performance. The
ventilation air velocity shall not fall below that specified in 5.7.2.3 (see 5.8.2.5.1.).
Failure of the ventilation system, or insufficient ventilation, shall be indicated by a visual and audible alarm (see
EN 981).
5.7.3
a) General
Heating devices using combustible substances shall comply with specific standards EN 746-1, EN 746-2, and
EN 525.
To avoid reintroduction of contaminated air, the fresh air inlet duct shall be positioned apart from the exhaust air
duct and (for indirect systems) the burner flue.
18
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
The forced ventilation system shall be interlocked with the gas fuel admission to the burner.
b) Direct fired systems
Measures shall be taken to ensure that the use of a direct make-up heating system does not lead to a
dangerous gas concentration from combustion exceeding the exposure limit values specified by worker health
legislation (for example see annex !D").
This can be achieved by a gas monitoring device which shuts down the heating system in the event of the
exposure limit values being exceeded (see annex !D").
The forced ventilation system shall be interlocked with the gas fuel admission to the burner.
Burners shall comply with EN 746-1.
5.7.4
When an automatic fire extinguishing system is installed, a warning device shall be provided, which sounds before
discharge of dangerous fire extinguishing materials.
5.8
5.8.1
To preclude the fast propagation of fire, all elements of construction of the combined booth and its equipment shall
comply with the requirements for fire prevention and protection of machines as described in EN 13478.
5.8.1.1
Elements of construction
ventilation ducts, which shall not affect the fire resistance of any wall traversed.
The heat insulation and small components parts material properties shall not support a fire or increase the risk of
fire.
Filters used for air inlet and cleaning of exhaust air, flexible connections and sealing mastics shall be made of
non-easily flammable material.
NOTE
5.8.1.2
Exhaust air ducts shall be provided with adequate hatches or removable sections for inspection and easy cleaning
purposes.
5.8.1.3
5.8.1.3.1
Heating devices
Ventilation air heating system (see 3.18)
19
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
The heating system shall not function unless forced ventilation or recirculation system is in operation.
The air generator inlet and burner flame shall be installed out of the spraying area and outside zone 2.
5.8.1.3.2
Over-temperature
Combined booths shall be equipped with a temperature limiting devices which in case of over-temperature (e.g. by
exceeding the maximum allowed temperature) will cut off the heating system (see 5.8.2.1).
Restart of the heating system shall not be automatic.
The temperature control device shall indicate the temperature inside the combined booth and the set point.
The temperature control and temperature limiting device shall be independent.
Temperature limitation shall not be required, if the heating medium, even in the case of operational failure, cannot
elevate the combined booth temperature above the maximum drying temperature.
After a breakdown of the heating device a purge of the air, within the combined booth to atmosphere shall be
activated.
It shall not be possible to start the heating device until this purge has been completed under the condition
described in 5.8.2.1.
5.8.1.3.3
Heating devices located inside the combined booth (e.g. IR-System, catalytic system) shall be designed so that
they are not capable of igniting paint aerosols and solvent vapours.
The following additional measures shall be taken:
in the spray mode an IR-System shall be protected against the coating material by a hood.
Safe distance between heating elements and coated surfaces shall be stipulated (see 7.2.2).
5.8.1.4
5.8.2.1
Forced ventilation
The following requirements shall apply during both operation modes of the combined booth.
Dilution of the flammable substances is achieved by forced ventilation which shall be calculated:
a) for the spraying mode (see example of calculation in annex A);
20
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
Hazardous area
The classification of hazardous zones is an integral part of the safety concept for explosion prevention. The ignition
prevention category of equipment and components implemented to combined booth is dependent on limitation of
flammable substance concentration by forced ventilation.
As the concentration of flammable substances is limited to 25 % of LEL, the internal volume of the combined booth
including ducts for recirculated and exhaust air and in external volumes but within a distance up to 1 m from
permanent openings are classified as zone 2 during spray mode.
NOTE
5.8.2.3
Ignition sources
5.8.2.3.1
General
In order to prevent hazardous by explosive atmospheres, the design and selection of electrical and non electrical
equipment shall ensure that ignition sources are avoided in any part of the system, where areas with explosion
hazard are classified (see 5.8.2.2) If electrical and non electrical equipment is implemented according to their
manufacturers instruction, then the completed system is of the same category of protection.
5.8.2.3.2
Electrical equipment
Electrical equipment installed and located in zone 2 shall be at least of category 3 complying with EN 60079-0 and
EN 60079-15.
In particular the following measures shall be considered:
21
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
for lighting devices fitted behind transparent impact resistant panels sealed to the booth structure, so that
solvent vapour inside the booth cannot ingress, IP 54 of EN 60529 is sufficient,
For motor outside the combined booths at least IP44 of EN 60529 shall be used. Motors shall not be
positioned within an exhaust air duct,
5.8.2.3.3
All non electrical equipment and components installed and located in potentially explosive atmospheres shall be
designed and constructed according to good engineering practice and shall be subjected to an ignition hazard
assessment in accordance with 5.2 of EN 13463-1:2001 to provide the protection required. The equipment shall
satisfy the requirements of EN 13463-1and EN 13463-5.
Category 3 equipment for installation in zone 2 shall not contain any effective ignition source in normal operation.
In particular the following requirements shall be observed:
hot surfaces of all apparatus inside the combined booth shall not able to ignite paint aerosols and solvent
vapours. The admissible temperatures of these hot surfaces are described in 6.4.2 of EN 1127-1:1997;
sparks caused by mechanical shocks, friction or collisions shall be avoided, especially for moving parts of fans
for exhaust and recirculation air;
fans for exhaust and recirculation air shall be protected in accordance with !EN 14986".
5.8.2.4
5.8.2.4.1
Forced ventilation
See 5.8.2.1.
5.8.2.4.2
Control systems
See 5.8.2.5.
5.8.2.4.3
Purging
See 5.8.2.1.
5.8.2.4.4
See 5.8.2.1.
5.8.2.4.5
See 5.8.2.1.
5.8.2.4.6
Alarms
Visual and audible alarms shall indicate all failures identified above. These failures are:
failure of heating
22
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
over temperature
5.8.2.5
5.8.2.5.1
Electrical control, monitoring and measurement systems which are used in safety related functions to avoid the
formation of
and
control of dampers,
monitoring the temperature of the heating surface on air as a function of maximum drying temperature,
5.8.2.5.2
Where hydraulic and pneumatic systems can affect the forced ventilation flow rate, and/or the prevention of
explosion or fire, their controls shall comply with at least category 1 of EN 954-1.
Hydraulic and pneumatic systems shall comply with EN 982 and EN 983.
5.9
To avoid hazardous explosive mixtures being created within the combined booth by reduction in the forced
ventilation flow rate, the fans shall not be fitted with any braking device which is initiated following mains power
failure. Measures to prevent uncontrolled start-up (restart) shall be incorporated (see EN 1037).
23
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
Locations of emergency exits shall be clearly indicated, for instance by luminous or powered exit signs.
6.1
General
Compliance is checked by a visual inspection (in particular with respect to moving parts) prior to commissioning.
6.2
Mechanical
Compliance is checked by the verification of the correct application of the requirements described in 5.2.1, 5.2.2
and 5.2.3.
The requirement of 600 lux minimum described in 5.2.3 can be checked by measurement.
This measurement may, for instance, be taken at the point of 1m above the centre of the booth floor with the
luxmeter reading vertically upwards.
6.3
6.3.1
Electrical
Contact with live parts
Compliance is checked by applying the EN 60204-1 before commissioning, in particular the tests of 20.2, 20.3
and 20.4 of EN 60204-1:1997 shall be carried out and the results shall be recorded.
6.3.2
6.4
Thermal
Verification of these requirements shall be made by measuring temperatures of easily touchable surfaces
according to EN 563.
6.5
Noise
The measurement of emission sound pressure level at operators positions and of sound power level shall be
carried out according to !EN 14462:2005".
6.6
Radiation
Compliance is checked by visual inspection of existence and correct installation of required safety equipment.
6.7
6.7.1
Dangerous substances
Contact with or absorption of dangerous fluids (paints, solvents)
24
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
6.7.2
6.7.2.1
Forced ventilation
Compliance is checked carrying out tests and taking measurements of air velocity in accordance with annex B.
6.7.2.2
Airflow
A smoke generator shall be placed in the paint application area to check that forced ventilation extracts the smoke.
6.7.2.3
Air velocity
Compliance is checked by verification of type of alarm installed and practical testing of the alarm.
6.7.3
If automatic fire extinguishing equipment is installed the fire alarm system shall be checked by visual inspection and
test.
6.8
6.8.1
Fire
materials used for the construction of the combined booth to comply with the requirements in 5.8.1.1;
6.8.2
6.8.2.1
Explosion
Forced ventilation
25
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
If the combined booth is a multizone booth, each section shall be considered separately for % of LEL calculation.
The % of LEL of the most unfavourable zone shall be used.
If the result of calculation is above 10 % of LEL, the measurement shall be effected by using an explosimeter.
The device shall be suitable for the use in explosive atmosphere.
This explosimeter shall be calibrated according to the manufacturers information.
Measurements shall be taken in the conditions of use (temperature, pressure, humidity etc.) specified by the
manufacturer of the apparatus.
Measurements shall not be taken at temperatures over the limit indicated by the manufacturer's explosimeter.
Measurements shall not be taken between the spray gun and item to be painted.
6.8.2.2
Hazardous area
Compliance of electrical and non electrical equipment with required categories for ignition protection shall be
checked before commissioning
All other requirements shall be checked visually.
The correct functioning of safety devices described in 5.8.2.3, 5.8.2.4 and 5.8.2.5 shall be checked.
6.8.2.4
Verification of the requirements and/or measures detailed in 5.8.2.4 may be carried out by inspection
and/or testing of the function of the measures during commissioning.
6.8.2.5
Verification of the requirement and/or measures detailed in 5.8.2.5 may be carried out by inspection
and /or testing of the function of the measures during commissioning.
6.9
Luminous warnings and lighting for emergency exits and their maintenance for 1hour to a minimum level of lighting
after the failure of energy supply shall be visually checked.
Safety circuits shall be checked before commissioning.
7
7.1
The manufacturer shall supply information for use for each combined booth.
Information for use shall be prepared in accordance with 5, and in particular with 5.5 (instruction handbook) and
with 6.4 (Marking) of EN ISO 12100-2:2003.
26
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
The information for use shall be written in the users language and shall be accompanied by a copy written in the
original language of the manual, chosen by the manufacturer. Both documents shall be drawn up in a language of
the European Economic Area (EEA).
Specifications for the installation, commissioning and use, shall be provided together with normal maintenance
information for the combined booth and the intended use.
7.2
Instruction handbook
7.2.1
General
instruction for use together with requirements for the training of personnel,
Warnings against:
any storage of flammable substances or their empty containers or any other materials which have been in
contact with these products (rags, paper, etc.) in the combined booth and in front of the doors,
use of naked flames, incandescent objects, equipment or items capable of generating sparks (tools,
equipment, etc.), in the combined booth,
smoking in the hazardous zone. A display showing No smoking shall be affixed on both sides of all
entrance doors of the combined booth,
damage to the eyes and burning, when using IR, on all entrance doors.
the use of trained and authorised personnel to make any adjustments to the combined booth for the operating
conditions according to the manufacturers specifications,
7.2.2
The instructions for use shall at least contain the following information:
information and instructions for installation (e.g. foundation requirements, required floor space),
information related to fitted safety devices and their function, as well as auxiliary devices,
27
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
attention to the special hazards including fuel vapours (e.g. from vehicle fuel tank, pipes), explosive materials
carried in the car (e.g. aerosol can, cigarette lighter), liquefied petroleum gas powered vehicles, batteries,
information on hazards which could occur despite the safety measures installed by the manufacturer (e.g.
instruction for loading by the user),
information regarding specific hazards generated by special applications (e.g. the potential fire risk from
IR-heating system, safe distance between heating elements and coated surface) or by using special
accessories,
building ventilation requirements: fresh air intake requirements shall be indicated so that the user can provide
any necessary inlets into the areas of installation,
information for correct restart procedures in case of failure of the forced ventilation or emergency stop, after an
interruption,
information about unintended use: warnings particularly dangers associated with high concentrations of
solvents, changing the coating products or the system,
instructions for detection of failures, repairs and clearance of faults (e.g. circuit diagrams for all services used
complete with a description),
appropriate arrangements (for example provision of suitable protective clothing) when contact with materials
used for spraying or cleaning could cause dermatitis or other skin complaints,
use of personal protection or a breathing mask connected to fresh air when an operator shall work inside train,
carriages, trucks, busses or in working pit within the booth,
the operating method to be followed in the event of accidents, breakdowns or blockages, that are likely to
occur."
7.2.3
check at regular intervals for the blocking of filtration and exhaust systems as well as deposits of coating
materials on equipment, walls and floor of the combined booth,
give precise instructions for maintenance of the heating device and especially the frequency of maintenance,
indicate the safety precautions to be taken if any source of ignition is taken into the combined booth,
28
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
use of materials and special tools of the manufacturer, if needed, and use of given instruction for working with
them,
requirements to switch off the power circuit before working on the ventilation system or automated damper
adjuster,
the specifications of the spare parts to be used, when these affect the health and safety of operators."
7.2.4
Intended use,
maximum amount of flammable solvents contained in the coating material applied in one hour,
temperature limits of the air inside the combined booth during the application mode,
maximum allowed pressure drop through filtration system (e.g. water-wash type, dry filter type).
7.3
Marking
the business name and full address of the manufacturer and, where applicable, his authorised
representative,"
the year of construction, that is the year in which the manufacturing process is completed,"
serial number,
mandatory marking,
maximum amount of flammable solvent contained in the coating material applied in one hour with indication of
LEL of solvent taken in reference in annex A,
29
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
maximum admissible quantities of flammable substances, which will be released in drying mode,
30
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
Annex A
(normative)
Determination of concentration of flammable solvents in terms of LEL
(spraying mode)
A.1 Equations
In order to simplify the comparison with the lower explosion limit (LEL), the concentration is expressed as cLEL in %
of LEL
c LEL =
100 c
LEL
(1)
The average concentration (mass) inside the combined booth depends on solvent input and airflow:
c=
M max k 1 k 2 k 3
Qmin
where :
c LEL
(2)
LEL
k1
k2
k3 = 3
Qmin
If the combined booth is a multizone booth, each section shall be considered separately for the cLEL calculation.
31
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
Mmax = 9 kg/h
K1 = 0,85 (85 %)
K2 = 0,80 (80 %)
K3 = 3
The minimum airflow Qmin can be calculated from the air velocity v and the width w and length l of the cross section
of airflow:
Qmin = v x w x l
According to (3):
According to (2):
According to (1):
(3)
Q min = 0,3 m/s x 4 m x 8 m x 3 600 s/h = 34 560 m/h
c=
c LEL =
100 x 0,53 g / m
= 1,3 % of LEL
40 g / m
Result:
If the forced ventilation of a combined booth is designed for a mean air velocity of v = 0,3 m/s, (and further
assumptions described above are valid) then an nominal concentration of cLEL= 1,3 % of LEL is maintained.
However the safety factor used in the calculation may lead to a true average concentration of 1/3 of that nominal
value.
Since cLEL = 1,3 % of LEL is far below the allowed maximum concentration value of 25 % of LEL , the combined
booth is operated in safe condition.
32
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
A.2.2 Determination of admissible maximum quantity of liquid organic coating material sprayed
per hour (Mmax) on base of given mean design air velocity and a special exposure limit
Assumptions
Combined booth/spraying mode with hand-held spray gun.
Size of the combined booth:
Mmax = ? kg/h
k1 = 0,85
k2 = 0,80
k3 = 3
According to (3):
According (2):
c=
M max =
M max x k 1 x k 2 x k 3
Qmin
c x Qmin
k1 x k 2 x k 3
0,190 g / m x 34 560 m / h
0,85 x 0,80 x 3
= 3,2 kg / h
=
M max
Result:
If the forced ventilation of a combined booth is designed for a mean air velocity of v = 0,3 m/s, and if the lowest
exposure limit to be observed of the coating material processed is 0,19 g/m, then an admissible Mmax = 3,2 kg/h
shall be processed within the combined booth is admissible processing of a maximum quantity
33
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
Annex B
(normative)
Measurement of air velocities
B.1 Instrumentation
The chosen equipment shall be directional and shall allow a measurement with an incertitude below or equal
to 0,05 m/s of the measurement in the range from 0,25 m/sec to 0,5 m/s.
a temperature compensation system for apparatus affected by temperature variations (e.g. thermal
anemometer).
In addition, the apparatus used shall have been calibrated around the measuring range within the past year.
Only the read and corrected value using the calibration graph shall be taken into account.
34
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
1m a < 1,5m
1m b < 1,5m
Figure B.1 Measurement points for air velocity of vertically ventilated combined booth
At each measurement point, air velocity shall be measured in the airflow direction, seeking the maximum value
which shall be retained.
In the case of an operator inside the combined booth, average and punctual measured values shall comply with
requirement given 5.7.2.3 a) and b).
35
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
at the entrance of fresh air plane when the operator does not work into the combined booth ;
or in a vertical plane located at 0,5 m from the entrance of fresh air plane when the operator works inside the
combined booth; this vertical plane is parallel to the actual surface of exhausted air.
The dimensions of this vertical plane are equal to the internal dimensions of the combined booth decreased by
0,25 m on all sides.
The measurement plane is divided in N equal rectangular areas (area over or equal to 1 m square side and less
than or equal to 1,5 m square side).
The centre of each area determines a measurement point (punctual point).
The distance between measurement points of two adjacent areas shall be less than or equal to 1,5 m.
Only the nearest value to 1,5 m shall be retained.
For small combined booths where calculation gives only one measurement point, the number of measurement
points shall be minimum two in the height and two in the width.
36
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
Key
1
Exhaust fan
Measurement plane
Measurement plane
Operator
Measurement points
Workpiece be coated
Figure B.2 Measurement points for air velocity of horizontally ventilated combined booth
37
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
At each measurement point, air velocity shall be measured in the airflow direction, seeking the maximum value
which shall be retained.
In the case of an operator inside the combined booth, average and punctual measured values shall comply with
requirement given in 5.7.2.3.b).
B.2.3 Measurement points for vertically ventilated combined booth used for spraying only one
large well-defined workpiece at a time
See 5.7.2.3.a).
Airflow direction shall be vertical.
They are located as indicated in figure B.3 and at 1 m above floor.
Key
1
Measurement points
Figure B.3 Measurement points for vertically ventilated combined booth used for spraying
only one large well-defined workpiece at a time
In the case of an operator inside the combined booth, average and punctual measured values shall comply with
requirement given in 5.7.2.3 a).
B.2.4 Measurement points for vertically ventilated combined booth with working pit
See 5.7.2.3.c).
Airflow direction in the working pit shall be vertical.
Measurement points shall be distributed along the longitudinal working pit axis.
38
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
The distance between measurement points shall be less than or equal to 1,5 m.
Measurement points shall be more than, or equal to 0,5 m from the working pit useful ends (access stairs
excluded).
Height of measurement points shall be 1 m above working pit floor circulation.
Average and punctual measured values shall comply with requirements given in 5.7.2.3 c).
39
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
!deleted text"
40
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
Annex C
(informative)
Classification of materials reaction to the fire National standards
The classification of materials of construction such as non combustible, not supporting fire, non easily flammable,
stated in 5.8.1 are used to describe the different characteristics of fire behaviour.
Currently, there are no harmonised EN-standards for the fire behaviour of materials for construction or for the fire
prevention and protection of machines (classification is being prepared by CEN/TC 127 in EN 13501-1 Fire
classification of construction products and building elements - Part 1: Classification using test data from reaction to
fire tests).
Therefore, national standards shall prevail until harmonised CEN standards are available.
They are:
Austria
Norm B 3800-1
Norm B 3800-2
Norm B 3800-3
Norm B 3800-4
United Kingdom
H.F.L '72
And
relevant parts of
BS 476
France
NF P 92-501
NF P 92-507
Germany
DIN 4102
Italy
UNI 9177
41
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
Annex D
(informative)
References to national exposure limit values
Exposure limit values are commonly defined by member states regulations. The national references - as far as
known - are as follows:
Country
A
B
CzR
DK
SF
F
G
ISL
IRL
I
L
NL
N
P
ES
S
CH
GB
42
Technical
terms for
limits
Amtliche Mitteilungen des Bundesministeriums fr soziale Verwaltung (2/93)
MAK,
TRK
Koninklijk Besluit tot wijziging van Bijlage II van Titel II, Hoofdstruk II bis van het VLE
ARAB wat de vaststelling van de grenswaarden voor blootstelling aan
chemische agentina betreft
Order in council on the modification of annex II of title II, chapter II bis from the VLE
ARAB that stablishes the limit of exposure to chemical agents
Ordonnance prise en conseil prive sur la modification de lannexe II du titre II,
VLE
chapitre II bis de lARAB qui etablit les limites dexposition des agents
chiminiques
Directive of Ministry of Health No. 58/1981 Coll., about principal hygienic NPK
requirements for maximum permitted concentration of the most important NPK-P
injurants in air und assessment of Level of pollution
Instruction No 3.1.0.2., December 1996, Exposure Limit Values for Substances GV
and Materials
At present unknown
Ministre du Travail: Dcret 84-1093: aration et assainissement des locaux de VMEI
travail
VLE
INRS ED 633: Guide pratique de ventilation - 9.Ventilation des cabines et
postes de peinture
Technische Regeln fr Gefahrstoffe TRGS 900 "Luftgrenzwerte"
MAK,
TRK
BAT
At present unknown
At present unknown
At present unknown
Threshold Limit Values and Biological Exposure Indices published by ACGIH TLV
American Conference of Governmental Industrial Hygienists (ACGIH)
At present unknown
Min. v. sociale Zaken en Werkgelegenheid P145: de nationale MAC-lijst 1996
MAC
Administrative normer for forurensing i arbeidsatmosfaere 1996
AT 361
At present unknown
At present unknown
(Threshold Limit values) AFS 1996:2 Hygieniska Grnsverden
NGV,
TGV
KTV
Suva Publikation: Grenzwerte am Arbeitsplatz 1997
MAK
Maximale Arbeitsplatzkonzentrationswerte gesundheitsgefhrdender Stoffe.
Biologische Arbeitsplatztoleranzwerte Arbeitshygienische Grenzwerte fr
BAT
physikalische Einwirkungen
Health and Safety Executive
MEL,
H&SE EH 40/97, Part 2: "List of occupational exposure limits and other tables" OES
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
Annex E
(informative)
Equivalence between zone description and categories of ignition protection
The zone classification for areas with potentially explosive atmosphere is corresponding to categories of ignition
protection according EN 13463-1.
Category Designed for type of explosive atmosphere
gas/air mixture resp.
1
vapour/air mixture resp.
mist/air mixture
gas/air mixture resp.
vapour/air mixture resp.
2
mist/air mixture
43
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
Annex ZA
(informative)
Relationship between this European Standard and the Essential
Requirements of EU Directive 98/37/EC !, amended by 98/79/EC"
This European Standard has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association to provide one means of conforming to Essential Requirements of the New
Approach Directive for Machinery 98/37/EC, amended by Directive 98/79/EC.
!Once this standard is cited in the Official Journal of the European Communities under that Directive and has
been implemented as a national standard in at least one Member State, compliance with the normative clauses of
this standard confers, within the limits of the scope of this standard, a presumption of conformity with the relevant
Essential Requirements (except Essential Requirements 1.2.3, 1.2.4, 1.1.2 c), 3) of that Directive and associated
EFTA regulations."
WARNING Other requirements and other EU Directives may be applicable to the product(s) falling within the
scope of this standard.
44
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
Annex ZB
(informative)
!Relationship between this European Standard and the Essential
Requirements of EU Directive 2006/42/EC
This European Standard has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association to provide a means of conforming to Essential Requirements of the Recast
Machinery Directive 2006/42/EC.
Once this standard is cited in the Official Journal of the European Communities under that Directive and has been
implemented as a national standard in at least one Member State, compliance with the normative clauses of this
standard confers, within the limits of the scope of this standard, a presumption of conformity with the relevant
rd
Essential Requirements ((except Essential Requirements 1.2.1, 3 paragraph, 1.2.3, 1.2.4, 1.1.2 c), 1.7.4.2 o), 3))
of that Directive and associated EFTA regulations.
WARNING Other requirements and other EU Directives may be applicable to the product(s) falling within the
scope of this standard."
45
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
Bibliography
[1]
EN 294:1992, Safety of machinery Safety distance to prevent danger zones being reached by the upper
limbs.
[2]
EN 349:1993, Safety of machinery Minimum gaps to avoid crushing of parts of the human body.
[3]
EN 574:1996, Safety of machinery Two-hand control devices Functional aspects, principles for design.
[4]
EN 614-1:1995, Safety of machinery Ergonomic design principles Part 1: Terminology and general
principles.
[5]
EN 619:2002, Continuous handling equipment and systems Safety and EMC requirements for equipment
for mechanical handling of unit loads
[6]
[7]
EN 811:1996, Safety of machinery Safety distances to prevent danger zones being reached by the lower
limbs.
[8]
EN 953:1997, Safety of machinery Guards General requirements for the design and construction of
fixed and movable guards.
[9]
[10]
[11]
[12]
EN 1760-1:1997, Safety of machinery Pressure sensitive protective devices Part 1: General principles
for the design and testing of pressure sensitive mats and pressure sensitive floors.
[13]
EN 1760-2:2001, Safety of machinery Pressure sensitive protective devices Part 2: General principles
for the design and testing of pressure sensitive edges and pressure sensitive bars.
[14]
[15]
EN ISO 3743-1:1995, Acoustics Determination of sound power levels of noise sources Engineering
methods for small, movable sources in reverberant fields Part 1: Comparison method for hard-walled test
rooms (ISO 3743-1:1994).
[16]
EN ISO 3744:1995, Acoustics. Determination of sound power levels of noise sources using sound pressure.
Engineering method in an essentially free field over a reflecting plane (ISO 3744:1994).
[17]
EN ISO 3747:2000, Acoustics Determination of sound power levels of noise sources using sound
pressure Comparison method for use in situ (ISO 3747:2000).
[18]
EN ISO 5167-1:2003, Measurement of fluid flow by means of pressure differential devices Part 1: Orifice
plates, nozzles and Venturi tubes inserted in circular cross-section conduits running full (ISO 5167-1:1991).
[19]
EN ISO 9614-1:1995, Acoustics Determination of sound power levels of noise sources using sound
intensity Part 1: Measurement at discrete points (ISO 9614-1:1993).
[20]
EN ISO 9614-2:1996, Acoustics Determination of sound power levels of noise sources using sound
intensity Part 2: Measurement by scanning (ISO 9614-2:1996).
46
materials
BS EN 13355:2004+A1:2009
EN 13355:2004+A1:2009 (E)
[21]
EN ISO 11688-1/AC:1998, Acoustics Recommended practice for the design of low-noise machinery and
equipment Part 1: Planning (ISO/TR 11688-1:1995).
[22]
EN ISO 11688-2, Acoustics recommended practice for the design of low-noise machinery and
equipment Part 2: introduction of the physics of low-noise design (ISO/TR 11688-2:1998).
[23]
EN 13501-1:2002, Fire classification of construction products and building elements Part 1: Classification
using test data from reaction to fire tests.
[24]
EN ISO 14122-1:2001, Safety of machinery Permanent means of access to machines and industrial
plants Part 1: Choice of a fixed means of access between two levels (ISO 14122-1:2001).
[25]
[26]
EN 50053-1:1987, Requirements for the selection, installation and use of electrostatic spraying equipment
for flammable spraying materials Part 1: Hand-held electrostatic paint spray guns with an energy limit of
0,24 mJ and their associated apparatus.
[27]
EN 60079-10:2003, Electrical apparatus for explosive gas atmospheres Part 10: Classification of
hazardous areas.
[28]
EN 60079-14:2002, Electrical apparatus for explosive gas atmospheres Part 14: Electrical installations in
hazardous areas (other than mines).
[29]
[30]
EN 61779-1:2000, Electrical apparatus for the detection and measurement of flammable gases Part 1:
General requirements and test method.
[31]
EN 61779-4:2000, Electrical apparatus for the detection and measurement of flammable gases Part 4:
Performance requirements for group II apparatus indicating a volume fraction up to 100 % lower explosive
limit.
[32]
PTB report W 57, Flammability characteristics of sprays of water-based paints (Ulrich von Pidoll/Helmut
Krmer), Physikalisch-Technische Bundesanstalt, Braunschweig/Germany February 1994.
47
BS EN
13355:2004
Copyright subsists in all BSI publications. BSI also holds the copyright, in the
UK, of the publications of the international standardization bodies. Except as
permitted under the Copyright, Designs and Patents Act 1988 no extract may be
reproduced, stored in a retrieval system or transmitted in any form or by any
means electronic, photocopying, recording or otherwise without prior written
permission from BSI.
This does not preclude the free use, in the course of implementing the standard,
of necessary details such as symbols, and size, type or grade designations. If these
details are to be used for any other purpose than implementation then the prior
written permission of BSI must be obtained.
Details and advice can be obtained from the Copyright & Licensing Manager.