Sei sulla pagina 1di 4

PROPOSAL FOR

CONSULTING AND DESIGNING


FOR DEVELOPMENT OF NEW
EFFLUENT TREATMENT PLANT AT
FLOWRATE OF 36 CUBIC METER
PER DAY

AT
Express Dairy Company Ltd.
- ---------------------------------------

Proposal by:
Headwheel System & Services Pvt. Ltd.

Untreated effluent quality:


i.
ii.
iii.
iv.
v.
vi.
vii.

Flow 1.5 m3/ hr. (0.036 MLD)


Temperature of water Ambient
pH - 6.8
TSS - 184mg/l
BOD 480 to 560 mg/l
COD 712 mg/l
Oil & Grease 6 mg/l

Existing effluent Treatment Plant:

Flow Diagram of Existing ETP

DIMENSION & SIZING OF EXISTING EFFLUENT TREATMENT PLANT:

1.1
i.
ii.
iii.
iv.
v.
vi.
vii.
viii.

Equalization Tank/Holding Tank


Average hourly flow 1.5 m3/ hr.
Peak factor 2 (Taking into consideration surge load due to any unforeseen
circumstances)
Design flow rate Say, 3 m3/ hr.
Effective volume of the Equalisation Tank 20 m3
Size of the Equalisation Tank 4 m (L) X 2 m (B) X 2.5 m (H) [Including free board =
0.5 m]
MOC RCC
Installation of automatic controller for with low and high level indication is to be done
to avoid accidental spillage.
Provision of one number Twin Lobe Blower of 300 m3/ hr. capacity at 4000 mm of WC
for the purpose of agitating untreated effluent in the equalization tank with coarse
bubble diffuser are to be made. Total number of diffuser plate of size 300 mm X 300
mm X 2.5 mm passes 1.2 m3/ min/ m2 of air with 0.4 mm pore size will be about 16 in
numbers. More specific estimate will be provided latter.

2.0

Rapid (Flash) Mixing Tank

i.
ii.
iii.
iv.
v.
vi.
vii.
viii.
ix.

Design flow rate 1.5 m3/ hr.


Hydraulic residence time - 60 Seconds
Design Tank Volume Required 0.025 m3
Effective standardized tank volume - 0.05 m3
Tank configuration - Cylindrical
Internal diameter of the tank - 0.35 m
Height of the tank (Including free board) - 0.525 m
Wall thickness - 0.075 m
Free Board 0.3 m

3.0

Primary Clarifier

i.
ii.
iii.
iv.
v.
vi.
vii.

4.0

Design flow rate- 1.5 m3/ hr.


Effective Volume - 3 m3
Overall volume - 4.7 m3
Hydraulic residence time - 2 hrs.
Diameter 2 m
SWD - 1.5 m
Free board - 0.5 m

Aeration Tank
Assumption: Inlet BOD 140 mg/l

i.
ii.
iii.
iv.
v.
vi.
vii.
viii.

Design flow rate- 1.5 m3/ hr.


Aeration tank inlet BOD 140 mg/l
Aeration tank outlet BOD 30 mg/l
MLSS 1500 mg/l
MLVSS 900 mg/l
SRT 12 days
Density of air 0.299 Kg - O2/ m3
Effective Volume - 15 m3 (Considering higher side value more than 10%)

ix.
x.
xi.

5.0
i.
ii.
iii.
iv.
v.

6.0
i.
ii.
iii.
iv.
v.
vi.
vii.
viii.
ix.

Overall volume - 18 m3
Hydraulic residence time - 0.3days (Or, 7.4 hrs.)
Size of the Aeration Tank 3 (L) X 2 m (B) X 3 m (SWD) [Free board = 0.5 m]
Oxygen requirement & diffuser calculation will be provided latter.

Moving Bed Biofilm Rector


Design flow rate- 1.5 m3/ hr.
Assumed organic loading rate- 3 kg/ m3of reactor volume/day
Aeration tank inlet BOD 30 mg/l
Effective Volume - 0.36 m3 or 5 m3
Volume of media - 0.1 m3

Secondary Clarifier
Design flow rate- 1.5 m3/ hr.
Surface Area 1.02 m2
Diameter 1.15 m
Effective Volume - 2.25 m3
Sludge Loading Rate 52.91 kg/m2/day
Overall volume - 2.75 m3
Hydraulic residence time 1.5 hrs.
SWD - 2.7 m
Free board - 0.5 m

Treated Effluent Quality


i.
ii.
iii.
iv.
v.

pH 7.5
TSS less than 30 mg/l
BOD - less than 20 mg/l
COD - less than 70 mg/l
O&G less than 1 mg/l

Potrebbero piacerti anche