Sei sulla pagina 1di 5

FACULTY OF CHEMICAL ENGINEERING

Universiti Teknologi MARA (UiTM) Terengganu


Kampus Bukit Besi,
Bukit Besi, Dungun, TERENGGANU

TECHNICAL/EXECUTIVE REPORT : CHEMICAL ENGINEERING


Lab No. :

Module :

Flowmeter Measurement
Apparatus
Mark

Measure flow meter

Topic :

Participant
*Please cancel which

:
Date :

Course : CHE 241


No.

Semester : 3
Name

is not necessary.

1
2
3

Muhammad Syimir Bin Ab Hamid


Idris Luqman Bin Nur Muhamad
Firdaus
Zulianey Bt Zaini

10

14 August 2015
Group:
Matrix No.

EH110_3C
Signature

201467291
6
201485011
8
201487772
2

1 Nurul Uyun Bt Ahmad

Instructor
2.
Objective :

To demonstration of the operation and characteristic of three different basic types of flowmeter

To determination of the loss coefficient when fluid flows through a 90 degree elbow

Abstract :

Flow Meter Measurement Apparatus is designed to operate together with a basic hydraulic bench or any
water supply. This is to shown different types of methods of flow measurement of an incompressible
fluid. This instrument is able to demonstrate the flow measurement comparison by using orifice, venture
and rotameter. In this experiment the fluid in motion is flow through different types of flow path.
Different path gives out different pressure, velocity and types of flow which are turbulent and laminar.
On each types of path there are different pressure drop produces, thus this apparatus is conducted in

order to obtain the exact properties of fluid flow in motion.

Data/Results
/Calculation:

Demonstration of the operation and characteristic of three different basic types of


flowmeter

A
439
410
383
362
358

B
418
399
377
361
359

C
282
325
340
350
350

Manometer reading (mm)


D
E
F
G
373 390 411 412
374 383 394 395
364 367 375 380
356 358 379 368
351 357 357 366

Rotamet
er
(L/min)

Vol (L)

Time
(min)

Flowrate
,Q
(L/min)

20

0.228

21.93

15

10

0.626

15.97

10

15

1.15

13.04

20

3.16

6.33

25

9.48

2.64

Sample calculation :
Flowrate =

liter
min

H
190
277
314
341
354

I
279
324
337
347
355

J
255
311
331
345
354

Flowrate calculated
using the Bernoullis
Equation (L/min)
Venturi
Orifice
1.1711 9.0351
0
06
8.8131 6.5871
04
06
6.1261 4.9261
04
06
3.2371 3.1511
04
06
2.6431 2.1011
04
06

5L
0.228 min

= 21.93 L/min
Venturi
P1=4306.59 Pa
P2=2766.42 Pa
Cd=0.98
q = Cd At (1- (At/A)) (2g(P1-P2)/
q=(1.97078104)(0.1435)][19.62(1540.17Pa)/1000)
= 1.17110
Orifice
h7=0.412 m
h8=0.19 m
Q= Cd At (1- (At/A)) (2g(h7-h8))
= (1.9707810-4)(0.1435) [19.62(0.412-0.19))
= 9.035106

Determination of the loss coefficient when fluid flows through a 90 degree elbow
Volume (L)
Time (s)
Flowrate,Q Diferrential
V (m/s)
V/2g
(L/min)
Piezometer
(mm)
Head,
(mm)

2
2
2
2
2
2
2

6
7
8
10
16
20
28

20
17.14
15
12
7.5
6
4.29

Elbow(hihj)
24
23
15
8
5
3
1

410
3.2910
1.87510
8104
3.125104
1.5104
3.57105

8.15104
5.52104
1.79104
3.26105
4.98106
1.15106
6.496108

Series 1

hi-hj

30
25
20
15
10
5
0

V2/2g

Discussion:

Conclusion:

(10-4)

https://www.coursehero.com/file/8491162/Flowmeter-Demonstration-full/
References:

Approval

Lab manual, Faculty of Chemical Engineering, UiTM Kampus Bukit Besi


Authorize Person
Technician

Initial

Date

Instructor

Allocated Marks for Technical/Executive report


Criteria
Abstract
Objective
Data/Results/Calculation
Discussion
Conclusion
References
Overall structure/organization and Quality
TOTAL

Comments:

Full Marks
10
10
20
30
10
10
10
100