Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
L/S PRECISION
VARIABLE SPEED
MODULAR DRIVES
Model Nos.
07557-00
07557-10
07557-60
07557-70
A-1299-1079B
Edition 02
Preface
symbol in this publication are registered in the U.S. and in other countries.
ORIGINAL INSTRUCTIONS
Cole-Parmer
ii
Preface
Safety Precautions
SAFETY
PRECAUTIONS
Explanation of
Symbols
WARNING:
Product Use
Limitation
Cole-Parmer
iii
Preface
Safety
iv
Cole-Parmer
Table of Contents
Page
Cole-Parmer
Section 1
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Application Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Controls, Indicators and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Section 2
Section 3
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
Inserting Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
Tubing Inspection and Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
Pump Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
Keypad Lockout Enable/Disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2
External Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2
External Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-3
Transmitter Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
Section 4
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1
Fuse Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-2
Motor Gear and Brush Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3
Section 5
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1
Troubleshooting Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1
Section 6
ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-1
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-1
Section 7
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-1
Section 8
Figures
Figures
Page
Controls, Indicators and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
DB-9 and NEMA 4X Pin Con guration with Wiring Scheme . . . . . . . . . . . . .3-2
Typical 4-20 mA Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
Fuse Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-2
Motor Gear and Brush Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3
Cole-Parmer
vii
Section 1
General Description
Introduction
Application Solutions
Cole-Parmer
Handle abrasive slurries and corrosive fluids with minimal wear. Ideal
for titanium dioxide or diatomaceous earth filter aid applications.
Low shearing for handling the most shear sensitive of fluids such as
latex or fire fighting foam.
Availability of tubing and tube materials that are suitable for food and
pharmaceutical use.
1-1
Section 1
Introduction
Controls, Indicators
and Connectors
H
A
F
G
Cole-Parmer
Section 2
The ambient air temperature should not exceed 104 F (40 C) and
adequate air flow should be provided for.
Use a tube size of appropriate diameter for the flow rate and
viscosity required.
Mounting the
Pump Head
Cole-Parmer
Mount Pump Head and load tubing (See Pump Head datasheets within
this CD). Check to ensure that rollers are clean and free of defects.
2-1
Section 3
Inserting Tubing
Operation
Pump Controls
Cole-Parmer
3-1
Section 3
Operation
Keypad Lockout
Enable/Disable
External Operation
Press and hold the INT/EXT key. After five (5) seconds, display will
change to all dashes. Release INT/EXT key and press UP ARROW key ()
five (5) times. Repeat this process to unlock the keypad. When the keypad
is locked out, display will change to display all dashes (- - - - -) when a key
is depressed.
Bench top models are equipped with inputs that can be controlled by
external signals connected at the rear panel 9-pin D shell connector.
NEMA 4X models are controlled at the bottom18-pin round connector.
The external inputs permit control of the pump by remote equipment or
accessories. Figure 3-1 indicates the signal locations in the connector.
DB-9
Pin No.
Description
NEMA 4X
Pin No.
1 (black)
3 (white)
5 (orange)
14 (red/yellow)
10 (grey)
8 (yellow)
4 (green)
CW/CCW
6 (blue)
9 (violet)
NOTE: Colors for NEMA 4X are those of the Remote Cable, Cat. number MN-77300-32.
3-2
Cole-Parmer
Section 3
Operation
External Inputs
Cole-Parmer
3-3
Section 3
Operation
Transmitter Type
3-4
Cole-Parmer
Section 4
Replacement Parts
Maintenance
Cole-Parmer
Part Number
Brushes (set of 2)
07520-04
07520-03
Fuse-T3.15A, 5 x 20 mm
77500-25
07553-06
07553-09
07553-08
50001-60
50001-62
50001-64
50001-68
50001-69
50001-70
50001-72
50001-74
50001-76
50001-78
4-1
Section 4
Maintenance
Section title
Fuse Replacement
B
B
4-2
Description
IEC Power Entry Module / Line Cord
3.15A (520 mm) Fuse Do Not Substitute
Cole-Parmer
Section 4
Maintenance
Section title
A
B
F
A.
B.
C.
D.
E.
F.
Cleaning
operation is started.
Keep the drive enclosure clean with mild detergents. Do not immerse or
use excessive fluid when cleaning.
Cole-Parmer
4-3
Section 5
Troubleshooting Chart
Troubleshooting
Symptom
Remedy
Cole-Parmer
Err's 3 & 10, check pump for obstructions, all other Errs
return unit for repair.
5-1
Section 6
Accessories
Accessories
77595-35
07528-80
07595-45
07595-47
07557-51
Cole-Parmer
1. Washdown Footswitch
07595-43
77300-32
07557-51
6-1
Section 7
Specifications
Output:
Speed:
07557-10, 07557-70
07557-00, 07557-60
Torque, Maximum:
600 rpm models
100 rpm models
Input:
Operating Voltage/Frequency:
External Inputs:
START/STOP, CW/CCW,
Remote/Local Speed Control
Voltage input
Accuracy:
Current input
Accuracy:
Environment:
Operating Temperature:
Storage Temperature:
Humidity:
Altitude:
Pollution Degree:
07557-00, 07557-10
07557-60, 07557-70
Noise Level:
Cole-Parmer
1 - 100 rpm
6 - 600 rpm
180 oz-in (13 kgcm), 540 oz-in Starting
360 oz-in (26 kgcm), 1080 oz-in Starting
90-260Vrms, 50/60 Hz, 2.2A @ 115Vrms,
1.1A @ 230 Vrms
Contact closure
010V DC @ 10 kohm,
0.5% Full Scale
420 mA @ 250 ohm,
0.5% Full Scale
32 to 104F (0 to 40C)
-13 to 149F (-25 to 65C)
10% to 90% non-condensing
Less than 6562 ft (2000 m)
Pollution degree 2 (indoor uselab, office)
Pollution degree 3
(Indoor use-sheltered locations)
<70 dBA @ 1 meter with Pump Head
7-1
Section 7
Specifications
Warranty,
Product Return and
Technical Assistance
Construction:
Dimensions (L W H):
07557-00, 07557-10
Controller:
10 1/2" 8 1/4" 5" (267 209.5 127mm)
Motor:
10 1/2" 4 1/8" 4 1/2" (267 105 114mm)
07557-60, 07557-70
Controller:
9" 11 3/4" 4 1/2" (229 298 114mm)
Motor:
15 9/16" 7" 6" (395 178 152mm)
Weight:
07557-00, 07557-10
Controller:
6.8 lbs (3.08kg)
Motor:
8.8 lbs (4kg)
07557-60, 07557-70
Controller:
9.46 lbs (4.29kg)
Motor:
21.6 lbs (9.8kg)
Color:
Light Grey (5% Black)
Material:
Aluminum, ABS plastic and vinyl
Enclosure Rating:
07557-00, 07557-10
IP33 per IEC-60529
07557-60, 07557-70
IP66 (NEMA 4X) per IEC-60529
Compliance:
UL 61010-1, CAN/CSA-C22.2 No. 61010-1
This product has been tested to the requirements of
CAN/CSA-C22.2 No. 61010-1, second edition,
including Amendment 1, or a later version of the
same standard incorporating the same level of
testing requirements.
(For CE Mark):
EN61010-1: (EU Low Voltage Directive) and
EN61326: (EU EMC Directive)
7-2
Cole-Parmer
Section 8
Warranty
Cole-Parmer
8-1
Section 8
Warranty, Product Return and
Technical Assistance
Product Return
Technical Assistance
8-2
If you have any questions about the use of this product, contact the ColeParmer or authorized seller.
Cole-Parmer
Printed in U.S.A.