Job steps
Hazards
Possible impact
Control measures
1.
Pre Deployment
Set up and test Slipping and falling (N,A,E)
welding Kit
2.
Deployment/
Recovery
Page 1 from 2
NO TESTING (welding) IS TO TAKE PLACE WITHIN 500m ZONE (PDS)exceptions only with platform approval
Contingency
Limb/torso/head/internal
injury due to fall (IN)
organs
Limb/torso/head/internal organs
injury during recovery (IN)
Incorrect manual handling practices
(N,A,E)
Breakage of cutting rig hose (N,A,E)
Fouling the diver (N,A,E)
3.
Operating
MANDATORY MEASURES BEFORE PERFORMING ANY WELDING: Next table to be read out by supervisor to diver, immediately before welding:
1.
2.
3.
4.
5.
6.
7.
8.
9.
TASK
Diver and supervisor have both read and understood the welding task plan and the relevant risk assessment.
The diver has adequate PPE/ work equipment- hard hat, visor/shield, rubber gloves, drysuit - according to applicable requirements.
The diver is placed securely, comfortably and must ensure that he is not between the torch and the earth clamp or standing in a bight of cable.
Ensure that the diver checks above him to see that there are no pockets where gases might collect and ignite.
Note gases may also collect in mud and under certain conditions the mud may already contain methane, another inflammable gas.
Diver must check to ensure that no molten slag or cut offs will drop onto him, his umbilical or other equipment.
Welding area must be properly prepared, skimmed and grinded.
Never turn the power on unless the diver asks for it and is ready to start welding immediately.
Ensure that the diver never has the power on when he is changing electrodes, when he leaves the worksite, returns to the basket or comes to the surface.
Page 2 from 2