Sei sulla pagina 1di 6

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental


Operations

Software Data

PRODUCT
ADMINISTRATION

DCSSIV - DO2000
Software Baseline Release Document

Part:
No.:
Vintage:
Page:
Date:
D1:
SCN:

4 - C9
GAA24350AW11VIIIc

01 / 1
1/6
18-Jan-1999
18-Jan-1999
GAA 30320AAA02

DO2000
Software Baseline Release Document

Authorization Date D1:

18-JAN-1999

Running on PCB:

GAA24353 E1

Software Version:

GAA30320AAA02

Document Revision:
Date

SCN

10-Feb-97
30-Apr-98

GAA30320AAA
GAA30320AAA01

R. L b
R. L b

15-JAN-99

GAA30320AAA02

R. L b

Copyright 1998 , OTIS GmbH Berlin

Author

Comment
Original Version
CTR 45-97-G318
compatible to previous version
compatible to previous version

No part of this document may be copied or reproduced in any form or by any means without the prior written consent of OTIS GmbH.

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental


Operations

PRODUCT
ADMINISTRATION

Software Data

DCSSIV - DO2000
Software Baseline Release Document

Part:
No.:
Vintage:
Page:
Date:
D1:
SCN:

4 - C9
GAA24350AW11VIIIc

01 / 1
2/6
18-Jan-1999
18-Jan-1999
GAA 30320AAA02

Quality Approvals
Function

Name

Originator

R. Lob

Software Responsible

Dr. Barten

Software Administrator

Dr. Spielbauer

Engineering Resp.

H. Horbrigger

Product Support

D. Schenkel

Product Qualification

Chr. Ernecke

Quality Assurance

R. Miller

NE - Field Operat. Dep

U. Lassen

Signature

Date

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental


Operations

Software Data

PRODUCT
ADMINISTRATION

DCSSIV - DO2000
Software Baseline Release Document

Part:
No.:
Vintage:
Page:
Date:
D1:
SCN:

4 - C9
GAA24350AW11VIIIc

01 / 1
3/6
18-Jan-1999
18-Jan-1999
GAA 30320AAA02

Software History
PCB

GAA24353E1
GAA24353E1
GAA24353E1

SCN

GAA30320AAA
GAA30320AAA01
GAA30320AAA02

Comments

Original Version
Corrections
default value of CLD_IDLE_VOLTAGE parameter
increased from 10% to 20%

Configuration Number
GAA 30320 AAA02

Configuration Identification
Local ETO baseline software for DO-1 (DO2000) GAA 24350 AW11
Applicable for all new Flash-Memories.

Engineering Authorization Date (D1)


18-Jan-1999

First Delivery from Component Factory (D3)


18-Jan-1999

Parent Baseline Number


GAA30320 AAA01

Product Changes
None

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental


Operations

PRODUCT
ADMINISTRATION

Software Data

DCSSIV - DO2000
Software Baseline Release Document

Part:
No.:
Vintage:
Page:
Date:
D1:
SCN:

4 - C9
GAA24350AW11VIIIc

01 / 1
4/6
18-Jan-1999
18-Jan-1999
GAA 30320AAA02

Deliverable Media
Flash-Memories can be ordered from Berlin as well as magnetic tape resp. diskette or can
be downloaded from Berlin VAX. All Intel-Hex-Files for programming Flash-Memories and
PS-Files for printing Standard Parameter Lists are located in the directory
MECSPUBLIC$ROOT:[MECSPUBLIC]
GAA30320AAA02.HEX

Flash-Memories
Programmed Flash ordering number

GAA 30320 AAA02 1

Blank Flash Eprom ordering number


with protected Boot Program
Burning instructions:
Intel-Hex-File
Start address
Processor
Check sum
Word length (bit)

GAA30325AAA1 or higher
( 250 ns, e. g. 29F010)

Blank label ordering number


Flash memory labeling data

GAA 102 AFL 4

GAA30320AAA02.HEX
0000
8031
BC06 Hex
8

GAA 30320AAA02 1
DO2000
Z13
0599
#BC06#
Z13:
Flash memory location on PCB
0599: week of programming
BC06: check sum

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental


Operations

PRODUCT
ADMINISTRATION

Software Data

DCSSIV - DO2000
Software Baseline Release Document

Part:
No.:
Vintage:
Page:
Date:
D1:
SCN:

4 - C9
GAA24350AW11VIIIc

01 / 1
5/6
18-Jan-1999
18-Jan-1999
GAA 30320AAA02

Dependencies
1) This software runs on the DCSS IV, version GAA24350AW11 or higher.
2) LMCSS software GBA30085FAA01 or higher runs on MCBII version
JBA26801AAF002 or higher.
3) This software is able to control the additional Interface Box (GAA24350AB1), which is
necessary if the DO2000 is controlled by a Relay Controller.

Open Items
none

Reference Documents
Field Component Manual including:
Cover (contents and revision)
Guide Lines
Startup Routine
Service Tool Users Guide
Service Tool Manual
Service Tool Reference List

4 - GAA 24350 AW11


4 - GAA 24350 AW11 I
4 - GAA 24350 AW11 II
4 - GAA 24350 AW11 IV a
4 - GAA 24350 AW11 IV b

OTIS

FIELD COMPONENT MANUAL

European and Transcontinental


Operations

PRODUCT
ADMINISTRATION

Software Data

DCSSIV - DO2000
Software Baseline Release Document

Part:
No.:
Vintage:
Page:
Date:
D1:
SCN:

4 - C9
GAA24350AW11VIIIc

01 / 1
6/6
18-Jan-1999
18-Jan-1999
GAA 30320AAA02

Qualification and Verification Procedure


The influence of the parameter - Close Idle Voltage has been tested thoroughly during
the software qualification tests of the basic software GAA30320AAA. The results of these
tests are documented in the Software Qualification Report, which is available on request.
Additional tests were done in the door-laboratory in Gien, which confirm that no problems
occured with higher voltage at close idle. See test report - CLDIDLEV.doc - from the
10.Dec. 1997 in the appendix.
A field test, done in France, confirms no problems with the adjustment of the Close Idle
Voltage, which has been increased from 10% to 20% ( see appendix).

Baseline Modification Report


1. Improvements
Item1.1: Default value for Close Idle Voltage = 20% :

At some door applications the close torque was not sufficient, if the DCSS reduces the
voltage after 15 sec staying in close idle mode. In these cases the Close Idle Voltage
could be adjusted by the parameter setup. For improvements the default value of this parameter has been increased from 10% to 20%.

Appendix:

Testreport CLDIDLEC.DOC

Confirmation of field test