Sei sulla pagina 1di 23

Domestic Water Meter

Contact Water Meter MTM


for cold water

Features
Nominal diameter DN15 to DN50
Cold water up to 30C
(safe up to 50C)
Operating pressure up to 16 bar
Control pressure 25 bar
Horizontal installation
Dry dial multi-jet wheel cold water
meter
Metrological class B
Very good initial sensibility
Excellent measuring results and long
stability
With protection against magnetic
manipulation
At the dry dial type optimal working
security is ensured also for polluted
and corrosive potable water
By order delivery with pulser for
required output
Possibility for additional pulser use
for fixed output

The high capacity magnetic clutch


gives permanent and slipless
momentum
Insered filter
Possibility for internal flow restrictor
utilization
The smallest reading value of the
counter device is 0.05 litre
Hermetically sealed counter device
Plastic based coating of high
strength ensures corrosion
protection

Elin Wasserwerkstechnik

Elin Wasserwerkstechnik

Domestic Water Meter


Contact Water Meter MTM
for cold water
Type
Nominal diameter

mm
m3/h

15

20

25

MTM
32

32

40

50

Nominal volumetric flowrate

DN
Qn

1.5

2.5

3.5

10

15

Maximal volumetric flowrate

Qmax

m3/h

10

12

20

30

4.5

5.6

13

13

13

24.5

31.5

Transitional volumetric flowrate

Qt

m3/h
l/h

120

200

280

400

480

800

3,000

Minimal volumetric flowrate

Qmin

l/h

30

50

70

100

120

200

450

l/h

<10

<10

<25

<25

<25

<45

<45

260
G 1 1/2
G 1 1/4

260
G 1 1/2
G 1 1/4

300

270

Flowrate at

P=1bar

Initial sensibility
Metrological class

Displayed min. quantity

Displayed max. quantity

165

190

260

zoll

G 3/4

G1

G 1 1/4

G2

G 2 1/2

mm

66

66

65

65

65

85

105

mm

36

38

45

45

45

45

51

mm

158

158

157

157

157

177

185

mm

98

98

102

102

102

130

130

kg

1.3

1.6

2.8

2.9

2.9

5.2

7.0

Connecting thread
Sizes

Weight

99 999

m3
mm

Built-in length

Width

0.05

Pulser
Impulse values

liter/pulse

Switching component

1 or 10 or 100 or 1,000

Switch protection

Reed switch, plug type


Switching voltage Umax = 100 V AC/DC

Reed

Switching current Imax = 0,5 A


Switching power Pmax = 0.2 W
Switching power Pmax = 0.2 W

Pulse duration

at meter stop continous pulse possible


Protection

IP 65

Minor technical changes may occur in the course of further development.

Overall dimensions:

B
B

ELIN Wasserwerkstechnik Ges.m.b.H.


Hainburgerstrae 33, A-1030 Wien
Tel.: +43(0)1/71670-0
Fax: +43(0)1/71670-99
www.ewt.at export@ewt.at

Elin Wasserwerkstechnik

Domestic Water Meter


Contact Water Meter MTM
for cold water
Dial:

MTM Qn 1,5 m3/h


Klasse B 00000000

Material:

0 0 0 0 0
Meter body:
Counter device:
Cover lens:
Wheel box:
Other applied material:

Head loss graph MTM

Brass
Plastic
Plastic, steel
Brass or plastic
Stainless steel

Typical error graph MTM

1.0

Flow m /h

0.5

N
D

N
D

20

0.02

N
D

0.01

30

32

Loss of head
bar

0.1
0.05

15

Error in measurement

+5%
0.2

25

d
an

N
D

N
D

40

0.005

N
D

50

+2%
0
-2%

-5%

0.002
0.001
0.5

4 5

10

20

Q min

30

Flow m /h

Measuring error curve:


Error limits:

In the upper measuring range between Qmax and Qt


In the lower measuring range between Qt and Qmin

2%
5%

ELIN Wasserwerkstechnik Ges.m.b.H.


Hainburgerstrae 33, A-1030 Wien
Tel.: +43(0)1/71670-0
Fax: +43(0)1/71670-99
www.ewt.at export@ewt.at

Qt

Qn

Q max

CORONA MWI 109


Multi-Jet Meter | Wet Runner

APPLICATION
Domestic water meter
FEATURES

4 Modular multi-jet domestic meter with inductive scanning (without magnetic


influence)

4 System capability, with standard applicable pulse output 1 l/pulse (inductive).

4
4
4
4
4
4
4

CORONA MWI can be externed in any way - with IZAR RADIO COMPACT
868 I (radio module) or IZAR PULSE I (pulse transmitter)
Extremely low pressure loss and considerably extended measuring range
Records very small amounts of water consumption
Maximum long-term accuracy and absolutely corrosion-resistant
Measuring data better than specified by calibration regulations
Strainer insert in inlet connection for cleaning without damaging the seal
Capable of withstanding any load for a short time
Fine adjustment by regulating plug

CORONA MWI 109Meter for horizontal pipes


Multi-Jet Meter | Wet Runner

GENERAL
Medium temperature range

Meter for horizontal pipes


0 ... 30

Temperature safety

0 ... 50

Ambient operating temperature

0 ... 55

Ambient storage temperature

0 ... 55

bar

16

Nominal pressure

PN

Display range

0.05 l ... 99,999 m

Pulse value

l/pulse 1
IP 68

Protection class

TECHNICAL DATA
Nominal flow rate
Nominal diameter

Q3

m/h

DN

mm

2.5
15

Overload flow rate

Q4

m/h

3.125

Transition flow rate

Q2

l/h

40

40

Minimum flow rate

Q1

l/h

25

25

l/h

Pressure loss at Q3

bar

0.36

0.47

Flow rate at 1 bar pressure loss

m/h

4.19

5.85

Q3

m/h

DN

mm

2.5
15

4
20

TH 8627

TH 8627

40 / 80 / 100

40 / 80 / 100 / 160

40

40

Starting flow rate

4
20

APPROVAL
Nominal flow rate
Nominal diameter
MID

Dynamic range horizontal


installation (Q3/Q1)
Dynamic range vertical
installation (Q3/Q1)

16.01.2012 2

CORONA MWI 109Meter for horizontal pipes


Multi-Jet Meter | Wet Runner

DIMENSIONS

Nominal flow rate


Nominal diameter

Q3

m/h

DN

mm

2.5
15

4
20

Overall length (DIN ISO 4064)

mm

165 / 170

190

Overall length with coupling

L2

mm

245

288

Inch

GB

G1B

Connection thread on meter


(ISO 228/1)
Connection thread of coupling
(DIN 2999)

Inch

Height

mm

33

37

Height

H1

mm

73

73

Diameter

mm

95

95

Weight without coupling

kg

1.3

1.4

Weight with coupling

kg

1.5

1.7

PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH

Pressure loss graph

Typical error graph

16.01.2012 3

CORONA MWI 109Meter for rising pipes


Multi-Jet Meter | Wet Runner

GENERAL
Medium temperature range

Meter for rising pipes


0 ... 30

Temperature safety

0 ... 50

Ambient operating temperature

0 ... 55

Ambient storage temperature

0 ... 55

bar

16

Nominal pressure

PN

Display range

0.05 l ... 99,999 m

Pulse value

l/pulse 1
IP 68

Protection class

TECHNICAL DATA
Nominal flow rate
Nominal diameter

Q3

m/h

DN

mm

Overload flow rate

Q4

m/h

Transition flow rate

Q2

l/h

40

Minimum flow rate

Q1

l/h

25

l/h

Pressure loss at Q3

bar

0.52

Flow rate at 1 bar pressure loss

m/h

5.56

Q3

m/h

DN

mm

4
20

Starting flow rate

4
20

APPROVAL
Nominal flow rate
Nominal diameter
MID

TH 8627

Dynamic range vertical


installation (Q3/Q1)

40 / 80 / 100 / 160

16.01.2012 4

CORONA MWI 109Meter for rising pipes


Multi-Jet Meter | Wet Runner

DIMENSIONS

Nominal flow rate


Nominal diameter

Q3

m/h

DN

mm

4
20

Overall length (DIN ISO 4064)

mm

105

Overall length with coupling

L2

mm

203

Inch

G1B

Inch

Connection thread on meter


(ISO 228/1)
Connection thread of coupling
(DIN 2999)
Height

mm

18

Height

H1

mm

108

Diameter

mm

95

mm

82

Weight without coupling

kg

1.7

Weight with coupling

kg

2.0

Width

PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH

Pressure loss graph

Typical error graph

16.01.2012 5

Domestic Water Meter


Contact Water Meter MNM
for cold water

Features
Nominal diameter DN15 to DN50
Cold water up to 30C
(safe up to 50C)
Operating pressure up to 16 bar
Control pressure 25 bar
Horizontal installation
Wet dial multi-jet wheel cold water
meter
Metrological class B and C
(Qn1.5 and 2.5)
Very good initial sensibility
Excellent measuring results and long
stability
By order delivery with pulser for
required output
Possibility for additional pulser use
for fixed output

The cover lens is made of hardened


class
Insered filter
Possibility for internal flow restrictor
utilization
The smallest reading value of the
counter device is 0.05 litre
Plastic based coating of high
strength ensures corrosion
protection

Elin Wasserwerkstechnik

Elin Wasserwerkstechnik

Domestic Water Meter


Contact Water Meter MNM
for cold water
Type
Nominal diameter

mm
m3/h

15

20

MNM
25

32

32

40

50

Nominal volumetric flowrate

DN
Qn

1.5

2.5

3.5

10

15

Maximal volumetric flowrate

Qmax

m3/h

10

12

20

30

4.5

5.6

13

13

13

24.5

31.5

Transitional volumetric flowrate

Qt

m3/h
l/h

22.5

120

37.5

200

280

400

480

800

3,000

Minimal volumetric flowrate

Qmin

l/h

15

30

25

50

70

100

120

200

450

l/h

<8

<10

<8

<10

<15

<15

<15

<45

<45

Flowrate at

P=1bar

Initial sensibility
Metrological class
Displayed min. quantity

Displayed max. quantity

165

190

260

zoll

G 3/4

G1

G 1 1/4

mm

75

75

mm

36

mm

167

mm
kg

Connecting thread
Sizes

Weight

99 999

m3
mm

Built-in length

Width

0.05
260
G 1 1/2
G 1 1/4

260
G 1 1/2
G 1 1/4

300

270

G2

G 2 1/2

76

76

76

85

120

38

45

45

45

45

51

167

168

168

168

177

200

98

98

102

102

102

130

130

1.55

1.8

2.7

3.0

3.0

5.2

7.0

Pulser
Impulse values

liter/pulse

Switching component

1 or 10 or 100 or 1,000

Switch protection

Reed switch, plug type


Switching voltage Umax = 100 V AC/DC

Reed

Switching current Imax = 0,5 A


Switching power Pmax = 0.2 W
Switching power Pmax = 0.2 W

Pulse duration

at meter stop continous pulse possible


Protection

IP 65

Minor technical changes may occur in the course of further development.

Overall dimensions:

B
B

ELIN Wasserwerkstechnik Ges.m.b.H.


Hainburgerstrae 33, A-1030 Wien
Tel.: +43(0)1/71670-0
Fax: +43(0)1/71670-99
www.ewt.at export@ewt.at

Elin Wasserwerkstechnik

Domestic Water Meter


Contact Water Meter MNM
for cold water
Dial:

MNM Qn 1,5 m3/h


Klasse B 00000000

Material:

0 0 0 0 0

Meter body:
Counter device:
Cover lens:
Other applied material:

Head loss graph MNM

Brass
Plastic
Hardened glass
Stainless steel

Typical error graph MNM

1.0

Flow m /h

0.5

0.1

N
D

0.05

15
N
D

20

0.02

N
D

0.01

30

32

Loss of head
bar

0.2

Error in measurement

+5%

25

d
an

N
D

N
D

40

0.005

N
D

50

0.002

+2%
0
-2%

-5%

0.001
0.5

4 5

10

20

Q min

30

Flow m /h

Measuring error curve:


Error limits:

In the upper measuring range between Qmax and Qt


In the lower measuring range between Qt and Qmin

2%
5%

ELIN Wasserwerkstechnik Ges.m.b.H.


Hainburgerstrae 33, A-1030 Wien
Tel.: +43(0)1/71670-0
Fax: +43(0)1/71670-99
www.ewt.at export@ewt.at

Qt

Qn

Q max

CORONA MDI 110


Multi-Jet Meter | Dry Runner

APPLICATION
Domestic water meter
FEATURES

4 Modular multi-jet domestic meter with inductive scanning (without magnetic


influence)

4 System capability, with standard applicable pulse output 1 l/pulse (inductive).

4
4
4
4
4
4
4

CORONA MDI can be externed in any way - with IZAR RADIO COMPACT
868 I (radio module) or IZAR PULSE I (pulse transmitter)
Extremely low pressure loss and considerably extended measuring range
Records very small amounts of water consumption
Maximum long-term accuracy and absolutely corrosion-resistant
Measuring data better than specified by calibration regulations
Strainer insert in inlet connection for cleaning without damaging the seal
Capable of withstanding any load for a short time
Fine adjustment by regulating plug

CORONA MDI 110Meter for horizontal pipes


Multi-Jet Meter | Dry Runner

GENERAL
Medium temperature range

Meter for horizontal pipes


0 ... 30

Temperature safety

0 ... 50

Ambient operating temperature

0 ... 55

Ambient storage temperature

0 ... 55

bar

16

Nominal pressure

PN

Display range

0.05 l ... 99,999 m

Pulse value

l/pulse 1
IP 65

Protection class

TECHNICAL DATA
Nominal flow rate
Nominal diameter

Q3

m/h

DN

mm

2.5
15

Overload flow rate

Q4

m/h

3.125

Transition flow rate

Q2

l/h

50

80

Minimum flow rate

Q1

l/h

31.25

50

l/h

10

Pressure loss at Q3

bar

0.38

0.53

Flow rate at 1 bar pressure loss

m/h

4.1

5.55

Q3

m/h

DN

mm

2.5
15

4
20

TH 8630

TH 8630

50 / 80

50 / 80

Starting flow rate

4
20

APPROVAL
Nominal flow rate
Nominal diameter
MID

Dynamic range horizontal


installation (Q3/Q1)

16.01.2012 2

CORONA MDI 110Meter for horizontal pipes


Multi-Jet Meter | Dry Runner

DIMENSIONS

Nominal flow rate


Nominal diameter

Q3

m/h

DN

mm

2.5
15

4
20

Overall length (DIN ISO 4064)

mm

165

190

Overall length with coupling

L2

mm

245

288

Inch

GB

G1B

Connection thread on meter


(ISO 228/1)
Connection thread of coupling
(DIN 2999)

Inch

Height

mm

33

37

Height

H1

mm

73

73

Diameter

mm

95

95

Weight without coupling

kg

1.11

1.16

Weight with coupling

kg

1.31

1.46

PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH

Pressure loss graph

Typical error graph

16.01.2012 3

CORONA MDI 110Meter for rising pipes


Multi-Jet Meter | Dry Runner

GENERAL
Medium temperature range

Meter for rising pipes


0 ... 30

Temperature safety

0 ... 50

Ambient operating temperature

0 ... 55

Ambient storage temperature

0 ... 55

bar

16

Nominal pressure

PN

Display range

0.05 l ... 99,999 m

Pulse value

l/pulse 1
IP 68

Protection class

TECHNICAL DATA
Nominal flow rate
Nominal diameter

Q3

m/h

DN

mm

Overload flow rate

Q4

m/h

Transition flow rate

Q2

l/h

80

Minimum flow rate

Q1

l/h

50

l/h

12

Pressure loss at Q3

bar

0.45

Flow rate at 1 bar pressure loss

m/h

5.77

Q3

m/h

DN

mm

4
20

Starting flow rate

4
20

APPROVAL
Nominal flow rate
Nominal diameter
MID

TH 8630

Dynamic range vertical


installation (Q3/Q1)

50 / 80

16.01.2012 4

CORONA MDI 110Meter for rising pipes


Multi-Jet Meter | Dry Runner

DIMENSIONS

Nominal flow rate


Nominal diameter

Q3

m/h

DN

mm

4
20

Overall length (DIN ISO 4064)

mm

105

Overall length with coupling

L2

mm

203

Inch

G1B

Inch

Connection thread on meter


(ISO 228/1)
Connection thread of coupling
(DIN 2999)
Height

mm

18

Height

H1

mm

108

Diameter

mm

95

mm

82

Weight without coupling

kg

1.54

Weight with coupling

kg

1.86

Width

PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH

Pressure loss graph

Typical error graph

16.01.2012 5

ALTAIR V3
Rotary Piston Meter

APPLICATION
ALTAIR water meter is characterized by its versatility. Its large measuring
chamber means that it can be used for submetering or as a main meter.
Additionally, it is suitable for different types of water.
ALTAIR is a modular meter and therefore can be fitted at any time with IZAR
RADIO reading system, IZAR DOSING or the pulse emitter IZAR PULSE,
gateway to other systems.
FEATURES

4 DN 15 to DN 40
4 Start flow rate 2 l/h for DN 15
4 Low head loss
4 Installation in all position
4 New register with modularity "Ha + Ti"
4 Glass/Metal register in option
4 MID to R=500
4
4 High dynamic range

ALTAIR V3
Rotary Piston Meter

METROLOGICAL DATA
Nominal diameter
Length*

DN

mm

mm

Nominal flowrate

Q3

m/h

R*

15
110

Q3/Q1

15
170

20
190

25
260

32
260

40
300

2.5

2.5

6.3

10

16

160

160

160

160

160

160

Starting flowrate

l/h

Min. constructor's flowrate

l/h

20

40

40

Min. flowrate

Q1

l/h

15.6

15.6

25

39.4

62.5

100

Transition flowrate

Q2

l/h

25.0

25.0

40

64

100

160

Maximum flowrate

Q4

m/h

3.12

3.12

7.87

12.5

20

m/h

10

20

20

Max. constructor's flowrate

* Other value on request

APPROVAL
MID approval

ALTAIR V3
LNE-5582

Alimentarity

ACS-WRC-KTW

TEMPERATURE AND PRESSURE


C

ALTAIR V3
0..30

NP

bar

16

DN

mm

mm

Width

mm

90

Height

mm

122

Thread connections standard

inch

3/4"

Thread connections (in option)

inch
kg

Medium temperature range


Nominal pressure

DIMENSIONS

Nominal diameter
Length*

Weight

15
110

15
170

20
190

25
260

32
260

40
300

90

90

170

170

170

127

127

190

190

190

3/4"

1"

1"1/4

1"1/2

2"

1"1/4

1.05

1.2

1.34

5.15

5.25

5.45

* Other value on request

11.01.2012 2

ALTAIR V3
Rotary Piston Meter

PRECISION CURVE

HEAD LOSS (DELTA P = Q/KVS)


Nominal diameter
Length*
Kvs

DN

mm

mm

15
110

15
170

20
190

25
260

32
260

40
300

4.24

4.24

16.97

16.97

20

OPTIONS
Pulse emitter IZAR PULSE : 1impulse/liter
Non-return valve - Connector pair - Glass copper register

11.01.2012 3

AQUARIUS S / RS / P
Single-Jet Meter

APPLICATION
For measuring consumption in apartments and buildings for billing purposes
FEATURES

4 Single-jet impeller meter of fully dry-running design with magnetic coupling


4 Modularity with the HYDROMETER system world
4 Excellent starting flow rate
4 Low pressure loss
4 Installation position: horizontal, vertical, riser pipe, downpipe
4 Compact design
4 Rotatable counter
4 Shield against static magnetic fields according to VDDW standard and EN
4
4

14154
Working pressure 10 bar according to DIN 2401
Protection class IP 54

AQUARIUS S / RS / P
Single-Jet Meter

GENERAL
AQUARIUS S / RS / P
Medium temperature range cold
water
Medium temperature range
warm water
Nominal pressure

PN

0 ... 30

0 ... 90

bar

10

Display range

0.1 l ... 9,999 m/h

EC type approval EO 6 30 C

D 98 / 6.131.09

EC type approval EO 6 90 C

D 98 / 6.331.93

Metrological class

A/BH

Protection class

IP 54

Note:
HYDROMETER single-jet impeller meters are delivered calibrated in accordance with the calibration regulations. (AQUARIUS P with 10
l/pulse cannot be calibrated.)

VERSIONS

AQUARIUS S
Nominal flow rate
Overall length

AQUARIUS RS

AQUARIUS P
1.5
80

1.5
110

1.5
130

2.5
130

AQUARIUS S - radio segment


retrofittable

AQUARIUS RS - radio segment


mounted

10 / 100

10 / 100

10 / 100

AQUARIUS P - pulse output

Qn

m/h

mm

l/pulse

Note:
AQUARIUS S: radio segment IZAR RS 868 or 434 MHz retrofittable
AQUARIUS RS: with mounted and configured radio segment IZAR RS 868 or 434 MHz
AQUARIUS P: pulse output by reed switch, cable length 2 m LiYY 2 x 0.25 mm, contact rating 24 V ~ 0.2 A, max. cable length 20 - 50
m (depending on electrical perturbation). Switching amplifier have to be used at a longer distance.

11.01.2012 2

AQUARIUS S / RS / P
Single-Jet Meter

TECHNICAL DATA
Nominal flow rate
Overall length

Qn

m/h

mm

1.5
80

1.5
110

1.5
130

2.5
130

Nominal diameter

DN

mm

15

15

15

20

Maximum flow rate (short-term)

Qmax

m/h

Transition flow rate horizontal

Qt

l/h

120

120

120

200

Transition flow rate any position

Qt

l/h

150

150

150

250

Minimum flow rate horizontal

Qmin

l/h

30

30

30

50

Minimum flow rate any position

Qmin

l/h

60

60

60

100

Starting flow rate horizontal

l/h

12

Starting flow rate any position

l/h

14

14

14

18

Pressure loss at Qn

bar

0.19

0.19

0.19

0.25

DIMENSIONS

Nominal flow rate


Overall length

Qn

m/h

mm

1.5
80

1.5
110

1.5
130

2.5
130

Overall length with coupling

L2

mm

160

190

210

228

Overall length with tap coupling

L2

mm

138

168

188

Connection thread on meter

Inch

GB

GB

GB

G1B

Connection thread of coupling

Inch

Height

mm

14

14

14

17

Height (AQUARIUS S / P)

H1

mm

52

52

52

52

Height (AQUARIUS RS)

H1

mm

69

69

69

69

Diameter

mm

64

64

64

64

Weight without coupling

kg

0.4

0.44

0.54

0.54

Weight with coupling

kg

0.58

0.64

0.72

0.72

11.01.2012 3

AQUARIUS S / RS / P
Single-Jet Meter

PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH

Pressore loss graph

Typical error graph

11.01.2012 4

Potrebbero piacerti anche