Sei sulla pagina 1di 5

CUSTOMER SERVICES DIRECTORATE

1 ROND POINT MAURICE BELLONTE


31707 BLAGNAC CEDEX FRANCE
TELEPHONE: + 33 (0)5 67 19 06 22
E-MAIL: monitored.retrofit@airbus.com

RETROFIT INFORMATION LETTER - RIL


Subject: Inspect retainers on CFM56-5A/-5B engines
SB Reference: A320-71-1070 Rev 00 dated 23 NOV 2015
Aircraft type: A320 Family
Our Ref.: SA71M15017693 Rev 00 dated 26 NOV 2015

MANDATORY

MANDATORY

MANDATORY

Linked to this Service Bulletin, an EASA Airworthiness Directive is expected to be issued DEC 2015.

1. Retrofit Purpose
Starting from March 2015 several batches of non-conforming Aft Engine Mount Inner Retainer Brackets were
either fitted on aircraft powered by CFM56-5A/-5B Engines in production or delivered to Operators and
maintenance organizations by the part supplier Goodrich Aerostructures.
Investigation identified that retainer P/N 238-0252-505 has different surface finishing which could be a
negative factor to the life of the inner retainer bracket.
Inspection Service Bulletin A320-71-1060 covered by EASA AD 2013-0050 was previously issued to perform
a one-time inspection and replace damaged Dull finish Retainers by Bright ones.
AIRBUS SB A320-71-1070 is requiring an inspection for any installed inner retainer brackets or spare parts
originated from the reported suspected batch of units as per Goodrich Aerostructures SB RA 32071-165.
Affected retainers must be replaced by conforming Parts.
Operators having accomplished AOT A71N011-15 prior to SB A320-71-1070 issuance do not have to apply
SB A320-71-1070.
SB A320-71-1070 enables the identification and replacement of the non-conforming retainers PN 238-0252505 from the affected population.
This AIRBUS monitored retrofit campaign is applicable to:
1. A320 Family aircraft with affected retainers PN 238-0252-505 fitted on engines listed in SB RA
32071-165
2. Operators having purchased retainers PN 238-0252-505 with Purchase Order references listed in
SB RA 32071-165.
3. Operators having installed retainers PN 238-0252-505 which may come from an affected Purchase
Order batch listed in SB RA 32071-165.

RIL ref.: SA71M15017693 Rev00

Page 1 of 3

AIRBUS S.A.S. 2014. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT

C80_Retrofit Information Letter - RIL_FM1403178_v3.0

Date: 26 NOV 2015

CUSTOMER SERVICES DIRECTORATE


1 ROND POINT MAURICE BELLONTE
31707 BLAGNAC CEDEX FRANCE
TELEPHONE: + 33 (0)5 67 19 06 22
E-MAIL: monitored.retrofit@airbus.com

RETROFIT INFORMATION LETTER - RIL


2. Retrofit Organization
Aircraft will be inspected by the Operator/MRO
1)

AIRBUS requests the Operator to return the RIL Appendix completed with A/C details and Operator's
contact for the retrofit and embodiment planning.

2)

Material Delivery planning will be defined by the AIRBUS Retrofit Department.


The Operator will place a Purchase Order with Goodrich Aerostructures Group for the material to be
ordered.

3)

P/N 238-0252-505 units affected in accordance with SB RA 32071-165 must be returned to the
Supplier.

4)

Goodrich Aerostructures Group will return compliant units to the Operator/MRO in accordance with
the quantity of units returned.

5)

After the accomplishment of the inspection on impacted aircraft, Airbus requests the Operator to
activate the usual reporting method (AirbusWorld or sb.reporting@airbus.com).

3. Retrofit Program
The SB associated with this retrofit program is MANDATORY and must be accomplished before the AD
compliance timeframe.
AIRBUS Retrofit Department will support the Operators up to this date as per below conditions.

Material

Man-Hours

Spare units
(in stock on shelves)

Free Of Charge for PO placed before 01-MARCH-2016

For the accomplishment of SB A320-71-1070 before 01-MARCH-2016,


please contact Goodrich Aerostructures for the credit of man hours indicated
in the SB RA 32071-165.

Included in the retrofit program

AIRBUS Retrofit Department is responsible for the overall retrofit organization.


Please contact: monitored.retrofit@airbus.com

RIL ref.: SA71M15017693 Rev00

Page 2 of 3

AIRBUS S.A.S. 2014. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT

C80_Retrofit Information Letter - RIL_FM1403178_v3.0

Date: 26 NOV 2015

CUSTOMER SERVICES DIRECTORATE


1 ROND POINT MAURICE BELLONTE
31707 BLAGNAC CEDEX FRANCE
TELEPHONE: + 33 (0)5 67 19 06 22
E-MAIL: monitored.retrofit@airbus.com

RETROFIT INFORMATION LETTER - RIL


4. Retrofit Material to be ordered
1)

Identified aircraft listed in SB RA32071-165


EQUIPMENT
SB RA32071-165

PN

QTY PER AC

Retainer

238-0252-505

6 (3 per Engine)

Operator Purchase Order shall be sent to the following:


Goodrich Corporation - Aerostructures Group
850 Lagoon Drive
Chula Vista, CA 91910-2098
Attention: Direct Airline Sales
(Service Bulletin No. RA32071-165)
Website: parts.asg.goodrich.com
eMail: sparesales@utas.utc.com
Goodrich Cage Code: 51563

2)

Identified affected retainer with Purchase Order listed in SB RA32071-165

Operator should contact Goodrich Aerostructures Communication Centre to request a Return Merchandise
Agreement (RMA) and obtain FoC replacement upon return of the suspect units as defined in SB RA32071165
Request for RMA is to be sent to sparesales@utas.utc.com
Retainers are to be sent to:
Goodrich Aerostructures Group
Customer Returns Bldg. 29, Door 20
Marina Parkway at G St., Gate 66,
Chula Vista, CA 91910-2098
Attention: Bldg 29 Service Bulletin RA32071-165
eMail: sparesales@utas.utc.com

In order to benefit from these retrofit conditions, Purchase Order shall mention "Material ordered for
Monitored Retrofit on SB A320-71-1070 (RIL ref. SA71M15017693)".

RIL ref.: SA71M15017693 Rev00

Page 3 of 3

AIRBUS S.A.S. 2014. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT

C80_Retrofit Information Letter - RIL_FM1403178_v3.0

Date: 26 NOV 2015

CUSTOMER SERVICES DIRECTORATE


1 ROND POINT MAURICE BELLONTE
31707 BLAGNAC CEDEX FRANCE
TELEPHONE: + 33 (0)5 67 19 06 22
E-MAIL: monitored.retrofit@airbus.com

RIL Appendix
Subject: Inspect retainers on CFM56-5A/-5B engines
SB Reference: A320-71-1070 Rev 00 dated 23 NOV 2015
Aircraft type: A320 Family
Our Ref.: SA71M15017693 Rev 00 dated 26 NOV 2015

The focal point for this modification within our Airline is:
Airline /ICAO:
Contact name:

Intended retrofit start date (DD MMM YYYY): ..


Operator's intention for this retrofit campaign is to perform this modification:
(please strike through the rejected proposals)

1. In House
2. With Our Maintenance and Repair Organization
Please advise name and place for MRO in this field

Additional comments:

RIL ref: SA71M15017693 Rev00

Page 1 of 2

AIRBUS S.A.S. 2014. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT

C80_Retrofit Information Letter - RIL Appendix_FM1403180_v2.0

Date: 26 NOV 2015

CUSTOMER SERVICES DIRECTORATE


1 ROND POINT MAURICE BELLONTE
31707 BLAGNAC CEDEX FRANCE
TELEPHONE: + 33 (0)5 67 19 06 22
E-MAIL: monitored.retrofit@airbus.com

RIL Appendix
Current retainer PN 238-0252-505 installed on aircraft
MSN or A/C Reg. Number

Engine 1 ASSY S/N

Engine 2 ASSY S/N

Spares (Purchase Orders as listed in Goodrich Aerostructures SB RA32071-165)


If not installed on A/C:
Purchase order reference

Installed on A/C:

If installed on A/C:

Yes / No

Please precise MSN

Mixed with other


retainers on shelf
Yes / No

Please return this document by e-mail to: monitored.retrofit@airbus.com

RIL ref: SA71M15017693 Rev00

Page 2 of 2

AIRBUS S.A.S. 2014. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT

C80_Retrofit Information Letter - RIL Appendix_FM1403180_v2.0

Date: 26 NOV 2015

Potrebbero piacerti anche