Sei sulla pagina 1di 6

BITZER Output data

Created on : 3/23/2014 10:02:33 PM

AMONIAC

BITZER Software v6.4.0 rev1076

3/23/2014 / All data subject to change.

2/6

Table of content
Project survey............................................................................................................................................................ 3
Compressor Selection: Open-Type Reciprocating Compressors.............................................................................. 4
Technical Data: W6FA............................................................................................................................................... 5
Open-Type Reciprocating Compressors.................................................................................................................... 6

AMONIAC

BITZER Software v6.4.0 rev1076

3/23/2014 / All data subject to change.

3/6

Project survey
Selected compressors
Open-Type Reciprocating Compressors

Chosen accessory
Please select a compressor type

1x

W6FA

AMONIAC

BITZER Software v6.4.0 rev1076

3/23/2014 / All data subject to change.

4/6

Compressor Selection: Open-Type Reciprocating Compressors


Input Values
Cooling capacity
Refrigerant
Reference temperature
Evaporating SST
Condensing SDT
Liq. subc. (in condenser)
Suct. gas superheat
Useful superheat
Motor speed
Drive
Capacity Control

90.0 kW
R717
Dew point temp.
-15.00 C
30.0 C
5.00 K
5.00 K
100%
1450 /min
Coupling (1:1)
100%

Result
Compressor
Capacity steps
Cooling capacity
Cooling capacity *
Evaporator capacity
Shaft power
Condenser Capacity
COP/EER
COP/EER *
Mass flow
Operating mode
Compr. speed
Necces. driving motor
Discharge gas temp. w/o cooling

W6FA
100%
66.8 kW
65.4 kW
66.8 kW
19.32 kW
86.1 kW
3.46
3.38
211 kg/h
Coupling (1:1)
1450 /min
30.0 kW
143.5 C

Additional cooling/ Limitations (see Limits + T. Data)!


Largest compressor with less than 900 RPM.
Starting point for motor selection see T. Data/ Notes
*According to EN12900 (5K suction gas superheat, 0K liquid subcooling)

Application Limits Standard


Legend
water cooled cylinder heads

AMONIAC

BITZER Software v6.4.0 rev1076

3/23/2014 / All data subject to change.

Technical Data: W6FA


Dimensions and Connections

Technical Data
Technical Data
Displacement (1450 RPM 50Hz)
Displacement (1750 RPM 60Hz)
No. of cylinder x bore x stroke
Allowed speed range
Weight
Max. pressure (LP/HP)
Connection suction line
Connection discharge line
Oil type NH3
Extent of delivery (Standard)
Oil charge
Protective charge
Suction shut-off valve
Discharge shut-off valve
Pressure relief valve
Water-cooled cylinder heads
Available Options
Coupling (..-K) w. A/C + medium
Coupling (..-K) w. low temp.
Coupling housing
Motor pulley (..-S)
V-belts
Discharge gas temperature sensor
Start unloading
Connection cooling water
Capacity control
Oil service valve
Crankcase heater
Oil pressure monitoring
Suction line filter

151,6 m3/h
183,0 m3/h
6 x 82 mm x 55 mm
900 .. 1750 1/min
161 kg
19 / 25 bar
NW 50
NW 40
Reniso KC68 (Standard)
5,0 dm3
Standard
Standard
Standard
Standard
Standard
KK620 [<22kW] / KK630 [<45kW] (Option)
KK625 [<22kW] / KK630 [<45kW] (Option)
Option
190, 210, 230 mm (Option)
5 x SPA (Option)
Option (incl. INT69VS)
Option
R 3/4''
100-66-33% (Option)
Option
140 W (Option)
MP55A (Option)
Option

5/6

AMONIAC

BITZER Software v6.4.0 rev1076

3/23/2014 / All data subject to change.

6/6

Open-Type Reciprocating Compressors


Motor Selection:
The required driving motor is selected for starting conditions at direct start as well as at star-delta- or PW-start with start
unloading (bypass + check valve). The starting conditions refer to the following defined operation points resp. to the
maximum application limit of the compressor. Should the evaporation- or the condensing temperature of the plant be
higher at the start, an individual motor selection is necessary.
Table of max. evaporation temperature for motor selection:
HH H M L
R134a +20C +12,5C -5C -20C
R404A/ R507A +7,5C -5C -20C
R22 +12,5C -5C -20C
NH3 +15C +10C -5C -The stated motor data refer to IEC motors at which the pull-up torque does not fall below 90% of the max. torque. In
addition the following starting torques (referring to direct starting torque) must be reached:
2-cylinder compressors 220%
4-cylinder compressors 180%
6-cylinder compressors 160%
Should the motor not fulfil these criteria, an individual selection is also necessary.
Condenser capacity:
The condenser capacity can be calculated with or without heat rejection. This option can be set in the menu PROGRAM/
OPTIONS. The heat rejection is constantly 5% of the power consumption. The condensing capacity is to be found in the
line cond.cap. (with HR) resp. cond.cap.
Legend of connection positions according to "Dimensions":
1 High pressure connection (HP)
2 Discharge gas temperature sensor (HP)
3 Low pressure connection (LP)
4 CIC system: spray nozzle (LP)
4b CIC sensor
5 Oil fill plug
6 Oil drain (magnetic screw)
7 Oil filter
8 Oil return (oil separator)
8* Oil return with NH3 and insoluble oil
9 Oil and gas equalization (parallel operation)
9a Gas equalization (parallel operation)
9b Oil equalization (parallel operation)
10 Crankcase heater
11 Oil pressure connection +
12 Oil pressure connection
13 Cooling water connection
16 Connection for differential oil pressure switch "Delta-P"