Sei sulla pagina 1di 236

User Manual

For machine type:


FV 623 CF

45M623N5UK-01

HOT SPOT PLATINUM Kernel 5.7

Austrian Gaming Industries GmbH


07 2008 AGI GmbH Wiener Strasse 158 . A-2352 Gumpoldskirchen . Austria . Europe . Tel.: +43-2252-606 . www.austrian-gaming.com . e-mail: support@novomatic.com

GENERAL

All technical information contained in this manual has been developed and compiled with great care and has been
reproduced taking advantage of advanced controlling mechanisms. The manufacturer reserves the right to make
changes to this manual at any time.
AUSTRIAN GAMING INDUSTRIES GmbH gives no guarantee and accepts no legal responsibility (neither as a
liability nor in any other way) for any errors and consequences that may arise from incorrect statements or
incorrect use.
The author welcomes any notifications of errors or ambiguities. The product names used in this manual may be
registered trademarks and / or brands of the relevant companies belonging to the Novomatic Group.
All rights reserved.
Any form of reproduction (printing, photocopying or other means) of any part of this manual, and any processing,
multiplying and distributing by the use of electronic systems shall be prohibited unless
AUSTRIAN GAMING INDUSTRIES GmbH has given written consent.
This manual is part of the device and must be passed on together with the device to any new owner or holder
of the device. It must be kept for the whole useful life of the device and must be accessible to technical staff
at all times.

This manual was created in accordance with the European norm EN 62079:2001 and is valid for
HOT SPOT PLATINUM (FV-623) Kernel 5.7
until a newer manual version is released. The version number of the User Manual is indicated as the
identification number on the inner page margin.
For identification of the device refer to the ID plate attached on either side of the device.
The plate also contains the required official approval symbol (CE, CSA).


Illustr. 0.1

space for official approval symbol

ID Plate

Copyright AUSTRIAN GAMING INDUSTRIES GmbH


NOVOMATIC GROUP OF COMPANIES
Wiener Strasse 158
2352 Gumpoldskirchen, Austria, Europe
Internet: www.austrian-gaming.com
Technical Support
Page 2

Tel.: +43 2252 606-300 Fax: +43 2252 607-001

E-Mail: support@novomatic.com
07 2008 AGI GmbH

45M623N5UK-01

The instructions contained in this manual must be strictly observed.

GENERAL

About this manual


This manual is meant to be a permanent source of reference for the user. The individual sections contain
important information about:

Installation

Handling

Use

Service

Repairs

45M623N5UK-01

This manual is divided into five sections. Each chapter explains a specific area of how to use the machine.
In the enclosure you find the table of illustrations and the glossary.
Part I

Introduction

general information of the machine


general information of different components and elements
technical data

Part II

Installation

installation and initialization of the machine

Part III

Troubleshooting

description of possible sources of errors

Part IV

Game and Software

error messages of the software


accounting system
possibilities of configuration and initialization

Part V

Hardware

description of individual components and elements of the machine

Annex

07 2008 AGI GmbH

table of illustrations
glossary

Page 3

GENERAL

Part I

I.1

I.2

I.3

Introduction
Operating elements
Description of components
Machine dimensions

7
9
10
11

Part II

II.1

II.2

II.3

II.4

Installation
Inspection (damages caused by transport)
Installation instructions
Power up
Safety precautions

13
15
15
16
17

Part III

III.1

III.2

Troubleshooting
Lack of line voltage supply
Error messages of the software

21
23
24

Part IV

Game and Software

25

IV.1
IV.2
IV.3
IV.4
IV.5
IV.6
IV.7
IV.8
IV.9

Part V

V.1

V.2

V.3

V.4

V.5

V.6

V.7

V.8

V.9

V.10

V.11

V.12

V.13

Error handling
Remote in
Handpay credit
Hopper refill
Hopper dump
Out of Service (Locking of the machine)
Top light
Audit Menu
RAM Clear

27
49
51
53
55
57
59
61
109

Hardware
Power supply
Bill acceptor
Coin acceptor
Hopper
Monitors
COOLFIRE Motherboard
COOLFIRE Backplane
Top light
Illumination
Mechanical meters
Door optics/switches
Loudspeakers
Preventative maintenance

111
115
119
127
135
139
145
151
165
169
177
181
185
189

Annex

Table of Illustrations

Glossary

Page 4

45M623N5UK-01

Table of Contents

195
197
199

07 2008 AGI GmbH

GENERAL

Legend

45M623N5UK-01

DANGER

Warns of dangerous situations to the user (e. g. risk of electric shock).

ATTENTION

Special, situation-related and action-related danger warnings.

INFORMATION

NOTE

TROUBLESHOOTING

Refers to a related subject / part of this manual.

07 2008 AGI GmbH

Provides further information and/or explanation.

Provides additional instructions and tips.

Explains the debugging of errors.

Page 5

GENERAL

Technical Data

Type

HOT SPOT PLATINUM FV-623 (Video)

Dimensions in mm (l x h x d)

540 x 2086 x 420


Weight

ca. 101 kg


Power supply


230 V / 50 Hz / 1,6 A

resp. 110 V / 60 Hz


Power

250 W


Fuses

T 3 A 15 (230 V)
T 5 A (12 V)

Place of identification details



ID-Plate on the side of the machine.

Thermal danger

Certain parts become hot during

operation and cause injuries!

Electrical danger

Whenever the machine is open,

voltaged parts can be touched!

Power down the machine whenever

you do repair or maintenance work!

Mechanical danger

Note that some flanges within the

device are sharp-edged and cause

injuries!

Improper opening and closing of the

device can lead to contusion!


Favourable operating temperature in C

10 - 35


Humidity in %

30% - 80%

(non-condensing)

Page 6

07 2008 AGI GmbH

45M623N5UK-01


Manufacturer

Austrian Gaming Industries

Wiener Strasse 158

A-2352 Gumpoldskirchen

Austria

Part I Introduction
I.1

Operating elements

I.2

Description of components

I.3

Machine dimensions

45M623N5UK-01

Austrian Gaming Industries GmbH


07 2008 AGI GmbH Wiener Strasse 158 . A-2352 Gumpoldskirchen . Austria . Europe . Tel.: +43-2252-606 . www.austrian-gaming.com . e-mail: support@novomatic.com

45M623N5UK-01

INTRODUCTION

Page 8

07 2008 AGI GmbH

INTRODUCTION

I.1 Operating elements

3
4
5
45M623N5UK-01

6
7

623FV_Ansichten.eps

Illustr. I.1.1 Operating elements

1 Attendant keyswitch
2 Coin slot
3 Bill insertion
4 Main door lock
5 Main door lever
6 Door in door lever
7 Door in door lock

07 2008 AGI GmbH

Page 9

INTRODUCTION

I.2 Description of components


7

8
1

10

12

14

16

11
13

45M623N5UK-01

15
17

18

19

FV623_Komponenten.eps

Illustr. I.2.1 Description of components

1 Loudspeaker (monitor mask)


2 Coin acceptor
3 Mechanical meters
4 Door in door illumination
5 Door optics (sender)
6 Loudspeaker (main door)
7 Top light
8 Monitors
9 Switching power supply (behind monitors)
10 COOLFIRE Motherboard

P a g e
10

11 Bill acceptor
12 COOLFIRE Backplane
13 Stacker door with lock
14 Hopper
15 Door optics (receiver)
16 Ticket printer (optional)
17 Switching power supply (behind stacker)
18 Main switch
19 Drop door with lock
07 2008 AGI GmbH

INTRODUCTION

I.3 Machine dimensions


Machine weight depending on model up to max. 101 kg (incl. base).

2086

600

1938

45M623N5UK-01

1231

107

420

540
Z_FV623CF_Abmessungen.eps

Illustr. I.3.1 Machine dimensions FV-623

07 2008 AGI GmbH

P a g e
11

45M623N5UK-01

INTRODUCTION

P a g e
12

07 2008 AGI GmbH

45M623N5UK-01

Part II

Installation

II.1

Inspection (damages caused by transport)

II.2

Installation instructions

II.3

Power up

II.4

Safety precautions

Austrian Gaming Industries GmbH


07 2008 AGI GmbH Wiener Strasse 158 . A-2352 Gumpoldskirchen . Austria . Europe . Tel.: +43-2252-606 . www.austrian-gaming.com . e-mail: support@novomatic.com

45M623N5UK-01

INSTALLATION

P a g e
14

07 2008 AGI GmbH

INSTALLATION

II.1 Inspection (damages caused by transport)


1) Remove the shipping carton and the material used to secure machine components during transport
(necessary only for some types of cabinet).
2) Should any damages caused by transport have occurred on the exterior, report them immediately
to the sender and have them confirmed by the same.

II.2 Installation instructions







It must be ensured that the machine is operated in an upright position. Further, the machine has to be
screwed down tightly to the base by means of the mounting material included in the delivery.
The minimum distance between two machines should be 21 cm to avoid possible damage when opening
the main door. The minimum distance to a possible back wall or the like should be 10 cm.
The drilling jig (see illustr. II.2.1) has to be used in case the machine is to be installed on a table provided
by the customer (i.e. if the machine has been delivered without base).

361.5

76.7

143.2

261.2

464.2

540

353.2

37.7

15(4x)

8(8x)

430

378.5

285.5

270.5

255.5

140.5

45M623N5UK-01

62

65.5

rear cabinet edge

Z_CS_Bohrschablone.eps

Illustr. II.2.1 Drilling jig

NOTE

The width of the drilling jig corresponds to that of the respective cabinet (540 cm),
the depth does not correspond, because this jig is used for various cabinet types!
Take the back cabinet edge as reference edge (i.e. the back edge of the drilling jig corresponds
to the back cabinet edge).
See the drilling scheme (Illustr. II.2.2) for the necessary drillings of the respective machine type.

07 2008 AGI GmbH

P a g e
15

INSTALLATION

See the ID plate (see illustr. 0.1) for the machine (cabinet) type.
For pilot drilling use two twist drills ( 10 mm and 5 mm).
After the required drillings have been made by means of the drilling jig, continue with
redrilling using a cylinder saw 60 mm.

45M623N5UK-01

Z_CS_Bohrplan.eps

Illustr. II.2.2 Drilling scheme

II.3 Power up
1) Before start check the line voltage. The machine has been designed to sustain 230 V 10%, 50 Hz
or 110 V 10%, 60 Hz. Make sure that the line voltage is corresponds to the voltage indicated on
the machine.
2) As all machines of the HOT SPOT PLATINUM Series are equipped with an earthing connection,
it should be ensured that the main supply is also equipped with an earthing connection.
3) Plug in the main plug correctly.
4) Open the main door.
5) If the machine is equipped with a coin comparitor, place the reference coin in there.
6) Refill the hopper.
7) Switch on the machine.
8) Close the main door.
9) After a short self test the machine is ready for operation.
10) Credits can be added and a new game can be started.

P a g e
16

07 2008 AGI GmbH

INSTALLATION

II.4 Safety precautions



For operating safety and to avoid damage to the machine, read carefully and observe
the following instructions.

Because the attendee responsible for usual maintenance has to open the machine, he has to
get informed about the safety precautions.

There are static-sensitive parts inside the machine which could be damaged by electric discharge.
Ground yourself by touching a ground strap inside the machine to neutralize electric charges
before changing or maintaining inner parts.

Ground straps inside machine


are marked with yellow stickers.

DANGER

In case of emergency power off the machine!

45M623N5UK-01

Only disconnect the power line from the outlet achieves a powerless machine!
For machine with uninterruptible power supply (UPS) you have to switch it off, too!
Unplugging the machine with wet hands can result in
a risk of electric shock!

If there are unusual smells or sounds coming from the machine, unplug the unit from the AC outlet
immediately and for machines with an UPS power it off, too.
Contact a qualified service personnel.
Continued operation may be dangerous and can result in a risk of fire or electric shock.

Do not open the cabinet by force


There are potentially dangerous high voltage components inside.
Opening the cabinet can result in a serious risk of fire hazard or electric shock.
There are no user serviceable parts inside.
Refer all service to qualified service personnel.

Never insert objects into the cabinet ventilation openings


Do not push any objects through cabinet ventilation slots as they may touch dangerous voltage points
or cause short circuits that could result in a risk of fire or electric shock.

Never spill liquid of any kind (coffee, wine, etc.) on the machine.
In case of an accident, this may result in a risk of fire or electric shock.
Unplug the unit and have it checked by qualified service personnel.

Never use a water jet to clean the device!


Do not use organic solvent like thinner or abrasive materials to clean the device!

07 2008 AGI GmbH

P a g e
17

INSTALLATION

Avoid damages to the wires

Do not lead anything onto the power cord and do not bruise or stretch any wires.
Damaged wires can result in a risk of fire or short circuit.
Keep the wires away from where people will walk on them or stumble and be injured.

ATTENTION

Environment

Suitable for indoor use only!


Do not expose the machine under any circumstances to rain or temperatures greater than 50 C.
The operating temperature must not exceed 35 C.
If the machine has been exposed to very low temperatures, do not power up it immediately.

Be aware not to exceed the operation humidity range of 30 % to 80 % (not condensing).

Do not install it close to radiator heating either.


Do not install the machine in locations with rapidly changing temperatures or excessive dust.
This could cause the risk of fire hazard, short circuit or other damages.

Provide adequate space for ventilation

Opening on top, sides and in the bottom of the cabinet are provided for ventilation.
To ensure proper operation and to prevent overheating, these openings should not be blocked
or covered.
To allow hot air to escape make sure that there is a minimum space of 10 cm between the machine
and a wall or alike.
If the machine becomes too hot, it might cause a fire hazard.

The machine has to reach room temperature (convenient temperature is 10 C to 35 C).

P a g e
18

45M623N5UK-01

07 2008 AGI GmbH

INSTALLATION

MISCELLANEOUS

Influence of magnetic fields

Do not install machines with CRT monitors close to strong magnetic fields like loudspeakers
or fluorescent lamps.
Those equipments could bias the monitor, unusual noises could be heard.

Machines with LCD monitor

Do not hit or scratch the surface. High pressure of sharp objects could cause irreparable damages.
To clean the surface use some absorbent cotton or soft cloth and a window cleaner.
If the display accidentally breaks and the liquid crystal material leaks, it should be kept away from
the eyes or mouth.
In case of contact with hands, legs or clothes, it must be washed away thoroughly with soap.

45M623N5UK-01

NOTE












If you follow these instructions closely and the machine is maintained and handled in a proper way,
it complies with the usual safety standards.
The manufacturer warns explicitly against predictable, unconventional use of the machine as well as
predictable malpractice. Do not bypass the built-in safety precautions in the machine!

We hereby disclaim any warranties for improper handling of the machine.

Arbitrary alterations and changes of the machine are prohibited for safety reasons.
For security reasons any changes and exchanges of defective parts have to be accomplished with
originally or manufacturer-registered parts.
The manufacturer calls attention to the fact that spare parts that were not delivered by the
Austrian Gaming Industries are neither tested or approved by AGI.
The installation and/or use of such parts might negatively affect the machines performance.
The manufacturer cannot be held responsible for errors that result from such parts.

07 2008 AGI GmbH

P a g e
19

INSTALLATION

The following service instructions are for use by qualified or trained personnel only.
The owner of the machine has to assure that only qualified or trained personnel perform services.
To avoid personal injury or damage to the equipment, do not perform any servicing other than
such contained in this manual.

45M623N5UK-01

ATTENTION

P a g e
20

07 2008 AGI GmbH

Troubleshooting

III.1

Lack of line voltage supply

III.2

Error messages of the software

45M623N5UK-01

Part III

Austrian Gaming Industries GmbH


07 2008 AGI GmbH Wiener Strasse 158 . A-2352 Gumpoldskirchen . Austria . Europe . Tel.: +43-2252-606 . www.austrian-gaming.com . e-mail: support@novomatic.com

45M623N5UK-01

TROUBLESHOOTING

P a g e
22

07 2008 AGI GmbH

TROUBLESHOOTING

ATTENTION

Each power up is followed by a short self test. Then the machine is ready for operation.
If this is not the case, check the machine for the following possible error sources.

III.1 Lack of line voltage supply



The power supply is primary secured at 230 V with two T3A15 inert single-pole fuses.
The primary fuses are located on the front of the main switch module (illustr. III.1.1).
More details regarding (a) defective line voltage(s) can only be given by measurements
with suitable devices.

If the error cannot be cleared, please see part V - Power supply for further information.

45M623N5UK-01

fuses T3A15

main switch

Z_Schaltermodul_lang.jpg

Illustr. III.1.1 Main switch with fuses

ATTENTION

Usually errors in the electronics can only be handled by an expert.


The exchange of parts is the quickest way to perform a repair if this is eventually necessary.
If no spare parts are at hand, make use of our technical support and send us the defective
electronic part together with a short error description.

07 2008 AGI GmbH

P a g e
23

TROUBLESHOOTING

III.2 Error messages of the software



After the machine has been powered up, the major parts of the machine (e.g. hopper, CPU board etc.)
are subject to a self test.

If this test has been successful, the machine switches automatically to the ready-for-play status.
The error management engages each malfunction and/or manipulation is detected.

If the machine detects an error, the corresponding code is shown on the screen (see illustr. III.2.1).

Error handling (procedures to rectify an error):


1) Turn the attendant key.
2) Clear the error.
3) Release the attendant key.
4) Usually the machine should now be ready for operation again.

S_Fehleranzeige_UK.eps

Illustr. III.2.1 Error display

P a g e
24

07 2008 AGI GmbH

45M623N5UK-01

If an error cannot be cleared this way, see part IV - Game and Software.

45M623N5UK-01

Part IV

Game and Software

IV.1

Error handling

IV.2

Remote in

IV.3

Handpay credit

IV.4

Hopper refill

IV.5

Hopper dump

IV.6

Out of Service (Locking of the machine)

IV.7

Top light

IV.8

Audit Menu

IV.9

RAM Clear

Austrian Gaming Industries GmbH


07 2008 AGI GmbH Wiener Strasse 158 . A-2352 Gumpoldskirchen . Austria . Europe . Tel.: +43-2252-606 . www.austrian-gaming.com . e-mail: support@novomatic.com

45M623N5UK-01

GAME & SOFTWARE

P a g e
26

07 2008 AGI GmbH

GAME & SOFTWARE

IV.1 Error handling

45M623N5UK-01

attendant keyswitch

Z_FV623CF_Seitenansicht.eps

Illustr. IV.1.1 Attendant keyswitch for error handling

If an error occurs, the machine will interrupt the current game and switch automatically to failure mode.
1) An acoustic signal can be heard.
2) The blue light of the top light is flashing slowly respectively the red light is on.
3) The error message together with a short description is shown in the middle of the screen.
Below the procedure how to clear the error is explained (see illustr. IV.1.3).

07 2008 AGI GmbH

Page 27

GAME & SOFTWARE

IV.1.1 Explanation for clearing errors


1) Locate the error code according to the tables on the next pages.
2) Activate the attendant keyswitch (acoustic signal stops).
The program switches to or remains in the AUDIT MENU.
Clear the error.

If more errors occur, activate the attendant keyswitch until all errors have been cleared.
If an error cannot be cleared this way, follow the instructions of the error code table.

Errors are displayed in two ways:

Internal errors (always called E 99 9):

S_FehlerCF2_E_99_9_UK.jpg

Illustr. IV.1.2 Internal error - Screenshot

Note the error and inform our technical support (+43 2252 606-300) about it.

Other errors
Error code

Error name

Error handling

S_FehlerCF2_E_2101_UK.jpg

Illustr. IV.1.3 Error message - Explanation of elements

P a g e
28

07 2008 AGI GmbH

45M623N5UK-01

3) Release the attendant keyswitch.


The machine switches back to the game mode, already existing credits remain
(except if a RAM Clear has been performed!).

GAME & SOFTWARE

INFORMATION

Some errors demand a RAM Clear.


Find out more about RAM Clear at part IV.9.

ATTENTION

ATTENTION

If an error message is triggered by a malfunction of non-activation of individual meters the device


must be removed from operation and the meters circuit board must be exchanged.

If any hardware components like stacker box, hopper or coin acceptor are missing, no start-up
of the machine is possible.
Before the start-up screen is displayed, an error message appears on the screen.
Quitting this error can force restart of the machine but new appearing of this error message
(depends on software version and missing components).

TROUBLESHOOTING

45M623N5UK-01

Switch off the machine and replace the missing hardware component.
Now after restarting the machine the error can be cleared by turning the attendant keyswitch.

For further information see the following error handling table!

07 2008 AGI GmbH

P a g e
29

GAME & SOFTWARE

IV.1.2 Overview of possible errors


Event messages (can be viewed in the AUDIT MENU under EVENTS)

27 8 - Stacker full

27 10 - Bill rejected

27 11 - Bill excessive rejected

33 2 - Ticket low

34 3 - Hopper full

35 6 - Residual ticket printout failure

50 2 - Real time clock modified

50 3 - Periodic memory cleared

50 4 - System shutdown

50 5 - System power up

50 6 - System restart

61 1 - RAM error recovered

EE 03 - Game disabled by network

EE 04 - Game resumed by network

EE 05 - Machine initialized

EE 06 - Service mode entered

EE 07 - Service mode left

EE 08 - Configuration option changed
45M623N5UK-01

Warning messages (can be viewed in the AUDIT MENU under EVENTS)



EE 02 - Game disabled by network

63 3 - Main Door open

63 6 - Door in Door open
Error messages of the Door logger

DL 1 - Doorlogger interface not responding

DL 2 - ROM CRC error

DL 3 - RAM battery low
Error messages of the game selector (Dongle

ED 1 - The Game Selector is manipulated

ED 2 - The Game Selector is missing

ED 3 - Game Selector RAM or ROM error

ED 4 - Game Selector: time limited

ED 5 - Game Selector: games limited

ED 6 - Game Selector: wrong machine number

ED 7 - Game Selector: wrong machine version

ED 8 - Game Selector: version conflict

ED 9 - Game Selector: Timeout occurred
Error messages of the Mikohn Jackpot Controller

EE 11 - Jackpot controller missing

EE 12 - Jackpot communication lost

P a g e
30

07 2008 AGI GmbH

GAME & SOFTWARE

Error messages of the system



E0
- Init machine required

E0 1 - Init game required

E2
- RAM test failed

E7 0 - Meters were disconnected

E7 1 - Meters disconnected

E7 2 - SIMM write line manipulated
Error messages of the display

JD 1 - Display not responding

JD 2 - Display software wrong

45M623N5UK-01

Error messages of the physical reels



4
- Undefined error at reel X

4 2 - Sensor 1 error at reel X

4 3 - Sensor 2 error at reel X

4 4 - Sensor 1 not found at reel X

4 5 - Sensor 2 not found at reel X






4
4
4
4
4
4
4

6 - Reel X manually moved


8 - Wrong returnposition at reel X
9 - Reel X software has changed
10 - Reel X software wrong
11 - Reel interface X changed
12 - Reel interface X ROM error
13 - Reel interface X not responding

Error messages of the battery



12 3 - RAM battery low

12 4 - RAM battery empty

12 5 - Real time clock failure

12 6 - Serial communication failure

12 7 - Mainboard hardware failure

12 8 - Real time clock not set
Error messages of the physical lightwheel

7 00 - Undefined error at Lightwheel

7 09 - Lightwheel software has changed

7 10 - Lightwheel software wrong

7 12 - Lightwheel interface ROM error

7 13 - Lightwheel interface not responding
Error messages of the cashless transfer

CL 1 - Cashless transfer failed

07 2008 AGI GmbH

P a g e
31

GAME & SOFTWARE

Error messages of the coin acceptor



21 0 - Diverter error

21 1 - Coin optics failure

21 2 - Coin in jam

21 3 - Coin acceptor wrong pulse

21 4 - Coin acceptor disconnected

21 5 - Coin yo-yo (coin reverse)

21 6 - Top diverter optics disconnected

21 7 - Bottom diverter optics disconnected

45M623N5UK-01

Error messages of the bill acceptor



27 0 - Power up with bill in acceptor

27 1 - Power up with bill in stacker

27 2 - Jam in bill acceptor

27 3 - Jam in stacker

27 4 - Bill acceptor disconnected

27 5 - No stacker box

27 6 - Bill acceptor cheated

27 7 - Bill acceptor failure

27 8 - Stacker full

27 A - Bill acceptor failure

27 B - Bill acceptor failure

27 C - Bill acceptor failure

27 D - Bill acceptor failure

27 E - Bill acceptor failure

27 F - Bill acceptor failure

27 G - Bill acceptor failure

27 H - Bill acceptor failure

27 J - Bill acceptor failure

27 K - Bill acceptor failure

27 L - Bill acceptor failure
Error messages of the printer

33 0 - Printer disconnected

33 1 - Printer is not ready

33 3 - No ticket

33 4 - Paper jam

33 5 - Error during printing
Error messages of the hopper

32 00 - Hopper coin out jam

33 00 - Hopper empty

34 0 - Hopper disconnected

34 1 - Hopper tilt

34 2 - Hopper low

34 4 - Hopper limit reached

P a g e
32

07 2008 AGI GmbH

GAME & SOFTWARE

Error messages of the limits



35 0 - Credit limit reached

35 1 - LA win limit reached

35 2 - Jackpot limit reached

35 3 - Jackpot won

35 4 - Jackpot limit reached

35 5 - Cash button pressed

35 7 - Noncash win

45M623N5UK-01

Error messages of the doors



63 0 - Logic area was open

63 1 - Logic area open

63 2 - Drop door open

63 4 - Stacker door open

63 5 - Main Door optic error
Error messages of the RAM

61 - RAM error

62 0 - ROM CRC error

65 0 - Bad EEPROM

65 1 - EEPROM CRC check failed

65 2 - EEPROM configuration mismatch

65 3 - EEPROM structure mismatch

65 4 - EEPROM changed

68 0 - Program ROM changed
Error messages of the blackbox

69 0 - Blackbox inoperable

69 1 - Blackbox CRC check failed
Error messages of the 7-digit display

76 0 - Digit display not responding

76 1 - Digit display ROM CRC failed

76 2 - Digit display ID CRC failed
Error messages of the touch screen

80 0 - Touch screen missing

80 1 - Touch screen invalid response

80 2 - Touch screen invalid checksum

80 3 - Touch screen controller error
Error messages of the coolfire board

99 9 - Internal error

07 2008 AGI GmbH

P a g e
33

GAME & SOFTWARE

IV.I.3 Error handling table in numeric order


CL 1 - Cashless transfer failed

Handling:
Turn/release the attendant key.
If the error cannot be cleared, check the cashless connection.

DL 1 - Doorlogger interface not responding

Handling:
Turn/release the attendant key.
If the error cannot be cleared, check the connectors and the cables of the door log.
If the error cannot be cleared, the door log has to be exchanged.

DL 2 - ROM CRC error

Handling:
Turn/release the attendant key.
If the error cannot be cleared, the ROM (door log program) has to be exchanged.
DL 3 - RAM battery low

Handling:
Turn/release the attendant key.
If the error cannot be cleared, the RAM battery has to be exchanged.
If the machine has been switched off, it may loose data or receive wrong data.

45M623N5UK-01

ED 1 - The Game Selector is manipulated

Handling:
Perform a RAM Clear (
see part IV.9 - RAM Clear).
If the error cannot be cleared, the game selector has to be exchanged.

ED 2 - The Game Selector is missing

Handling:
Turn/release the attendant key.
Check the game selector. If the error cannot be cleared, ensure that the game selector is
properly seated.

ED 3 - Game Selector RAM or ROM Error

Handling:
Perform a RAM Clear (
see part IV.9 - RAM Clear).
If the error cannot be cleared, the game selector has to be exchanged.

ED 4 - Game Selector: time limited

Handling:
Turn/release the attendant key.
Check the game selector. If the error cannot be cleared, the game selector has to be exchanged.

P a g e
34

07 2008 AGI GmbH

GAME & SOFTWARE

ED 5 - Game Selector: games limited

Handling:
Turn/release the attendant key.
If the error cannot be cleared, the game selector has to be exchanged.

ED 6 - Game Selector: wrong machine number

Handling:
Turn/release the attendant key.
Check the game selector. If the error cannot be cleared, the game selector has to be exchanged.

ED 7 - Game Selector: wrong machine version

Handling:
Turn/release the attendant key.
Check the game selector. If the error cannot be cleared, the game selector has to be exchanged.

ED 8 - Game Selector: version conflict

Handling:

Turn/release the attendant key.


Check the game selector. If the error cannot be cleared, the game selector has to be exchanged.

45M623N5UK-01

ED 9 - Game Selector: timeout occurred

Handling:
Turn/release the attendant key.
Check the game selector. If the error cannot be cleared, the game selector has to be exchanged.

EE 11 - Jackpot Controller missing

Handling:
Turn/release the attendant key.
If the error cannot be cleared, the connectors of the jackpot controller have to be checked.

EE 12 - Jackpot Communication lost

Handling:
Turn/release the attendant key.
If the error cannot be cleared, the connectors of the jackpot controller have to be checked.

E0

- Init machine required

Handling:
Occurs after a RAM Clear. The basic settings must be made
(
see MACHINE > INITIAL SETUP).

E0 1 - Init game required

Handling:
Occurs after a RAM Clear. The basic settings must be made (

07 2008 AGI GmbH

MACHINE > GAME SETUP).

P a g e
35

GAME & SOFTWARE

E2

- RAM test failed

Handling:
Switch off/on the machine.
If the error cannot be cleared, the Coolfire mainboard has to be exchanged.

E7 0 - Meters were disconnected

Handling:
Turn/release the attendant key.

E7 1 - Meters disconnected

Handling:
Connect the meters.
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door and power down the machine.
Check the connectors of the meters Pay attention to any signs of manipulation attempts.
Power up the machine and close the Main Door.
If the error cannot be cleared, the meters have to be exchanged.

E7 2 - SIMM write line manipulated

JD 1 - Display not responding

Handling:
Turn/release the attendant key.
If the error cannot be cleared, check the connectors and cables of the display.
If the error cannot be cleared, the display has to be exchanged.

JD 2 - Display software wrong

45M623N5UK-01

Handling:
The Coolfire mainboard has to be exchanged.

Handling:
Turn/release the attendant key.
If the error cannot be cleared, check the connectors and cables of the display.
If the error cannot be cleared, the display has to be exchanged.

- Undefined error in reel X

Handling:
Open the Main Door and turn the attendant key.
Check the reel module systematically, release the attendant key and close the Main Door.

4 2

- Sensor 1 error in reel X

P a g e
36

Handling:
Open the Main Door and turn the attendant key.
Check whether the reel has worked itself loose from the axis or if the sensor on the
PCB reel light barrier (P366) is dirty. Release the attendant key and close the Main Door.
If the error cannot be cleared, the defective reel has to be exchanged.

07 2008 AGI GmbH

GAME & SOFTWARE

4 3

- Sensor 2 error in reel X

4 4

- Sensor 1 not found at reel X

45M623N5UK-01

4 6

4 8

4 9

Handling:
Open the Main Door and turn the attendant key.
Release the attendant key and close the Main Door.
If the error cannot be cleared, the reel may be damaged, has loosened from the motor axis
or is touching it.

- Wrong return position at reel X

Handling:
Open the Main Door and turn the attendant key.
Check if the sensors are dirty or defective. Release the attendant key and close the Main Door.
If the error cannot be cleared, the defective reel has to be exchanged.

- Reel X manually moved

Handling:
Open the Main Door and turn the attendant key.
Check if the sensors are dirty or defective. Release the attendant key and close the Main Door.
If the error cannot be cleared, the defective reel has to be exchanged.

4 5 - Sensor 2 not found at reel X

Handling:
Open the Main Door and turn the attendant key.
Check whether the reel has worked itself loose from the axis or if the sensor on the
PCB reel light barrier (P366) is dirty. Release the attendant key and close the Main Door.
If the error cannot be cleared, the defective reel has to be exchanged.

Handling:
Open the Main Door and turn the attendant key.
Release the attendant key and close the Main Door.
If the error cannot be cleared, the respective reel module and/or the LED/lamp controller board
has to be exchanged.

- Reel software X changed

Handling:
Turn/release the attendant key.

4 10 - Reel X software wrong

Handling:
Open the Main Door and turn the attendant key.
Perform a RAM Clear (
see part IV.9 - RAM Clear).
If the error cannot be cleared, the reel software has to be exchanged.
The reel software is placed on the reel interface.

4 11 - Reel interface X changed

Handling:

Turn/release the attendant key.


07 2008 AGI GmbH

P a g e
37

GAME & SOFTWARE

4 12 - Reel interface X ROM error

4 13 - Reel interface X not responding

Handling:
Open the Main Door and turn the attendant key.
Exchange the reel software on the reel interface. If the error cannot be cleared,
the reel software has to be exchanged. Release the attendant key and close the Main Door.

Handling:
Open the Main Door and turn the attendant key.
Release the attendant key and close the Main Door.
If the error cannot be cleared, the respective reel module and/or the LED/lamp controller board
have to be exchanged.

7 00 - Undefined error at lightwheel


Handling:
Turn/release the attendant key.
If the error cannot be cleared, check the connectors and cables of the lightwheel and/or change
the lightwheel interface.


7 09 -


Lightwheel software has changed


Handling:
Turn/release the attendant key.
If the error cannot be cleared, the connectors of the lightwheel should be checked.


7 10 -


Lightwheel software wrong


Handling:
Turn/release the attendant key.
If the error cannot be cleared, the lightwheel software has to be exchanged.

7 12 - Lightwheel interface ROM error

Handling:
Turn/release the attendant key.
If the error cannot be cleared, the interface ROM of the lightwheel or the lightwheel board
needs to be exchanged.

7 13 - Lightwheel interface not responding

45M623N5UK-01

Handling:
Turn/release the attendant key.
If the error cannot be cleared, check the connectors and cables of the lightwheel and/or
change the lightwheel interface.

12 3 - RAM battery low

P a g e
38

Handling:
Turn/release the attendant key.
The RAM battery has to be exchanged as soon as possible.
If the machine has been switched off it may loose data or receive wrong data.

07 2008 AGI GmbH

GAME & SOFTWARE

12 4 - RAM battery empty

12 5 - Real time clock failure

Handling:
Power down/up the machine.
If the error cannot be cleared, the mainboard has to be exchanged.
If the machine has been switched off it may loose data or receive wrong data.

Handling:
Turn the attendant key and check the time set. If necessary, adjust it.
The RAM battery may be empty.
If the error cannot be cleared, the mainboard has to be exchanged.

12 6 - Serial communication failure

Handling:
Turn/release the attendant key.
If the error cannot be cleared, check the network cables.

12 7 - Mainboard hardware failure

45M623N5UK-01

Handling:
Turn/release the attendant key.
If the error cannot be cleared, the mainboard has to be exchanged.

12 8 - Real time clock not set

Handling:
Turn the attendant key and open the Main Door.
Set current date and time in the real-time clock
(
see part IV.8 - AUDIT MENU > CALIBRATION > CLOCK SETUP).
Close the Main Door and release the attendant key.

21 0 - Diverter error

07 2008 AGI GmbH

Handling:
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door and power down the machine.
Check the coin diverter and the coin channels for jammed coins. Also check the connecting plugs
and the cables of the magnet. Power up the machine and close the Main Door. Perform the
coin diverter test (
see part IV.8 - AUDIT MENU > DIAGNOSTIC > COIN DIVERTER TEST).
If the error cannot be cleared, the coin diverter or the coin acceptor should be exchanged.
Also, the sensors may be defective, or may need to be re-adjusted.

P a g e
39

GAME & SOFTWARE

21 1 - Coin optics failure

21 2 - Coin in jam

Handling:
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door and power down the machine.
Check the coin acceptor for any signs of manipulation attempts. Check the connectors and the
cables of the coin acceptor systematically. Power up the machine and close the Main Door.
If the error cannot be cleared, the coin acceptor has to be exchanged
(
see part V - Coin acceptor).

21 4 - Coin acceptor disconnected

Handling:
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door and power down the machine.
The light barrier of the coin channel was blocked too long or a coin is stuck. Remove coins stuck
and check the connectors and cables of the light barrier.
Power up the machine and close the Main Door.

21 3 - Coin acceptor wrong pulse

Handling:
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door and power down the machine.
Check the coin acceptor and the coin channel optics for dirt or damage.
Furthermore, check the connectors and the cables of the coin optics and the coin acceptor.
The three light barriers have to be placed in the centre of the borings, the optical line between
transmitter and receiver must not be blocked. Power up the machine and close the Main Door.
If the error cannot be cleared, the coin acceptor or the light barriers have to be exchanged
(
see part V - Coin acceptor).

Handling:
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door and power down the machine.
Check the connectors and the cables of the coin acceptor systematically. Power up the machine
and close the Main Door. If the error cannot be cleared, the coin acceptor has to be exchanged
(
see part V - Coin acceptor).

21 5 - Coin yo-yo (coin reverse)

P a g e
40

Handling:
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door and power down the machine.
Check the coin acceptor for any signs of manipulation attempts. Furthermore, please check if a
reference coin is placed in the coin comparitor. Check the connectors and the cables of the coin
acceptor systematically. Power up the machine and close the Main Door.
If the error cannot be cleared, the coin acceptor or the coin diverter has to be exchanged
(
see part V - Coin acceptor).
Also, the sensors may be defective or may need to be re-adjusted.

07 2008 AGI GmbH

45M623N5UK-01

GAME & SOFTWARE

21 6 - Top diverter optics disconnected

21 7 - Bottom diverter optics disconnected

Handling:
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door and power down the machine.
Check the connectors and cables of the top coin optics.
Power up the machine and close the Main Door.
If the error cannot be cleared, the top coin optics have to be exchanged.

Handling:
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door and power down the machine.
Check the connectors and cables of the bottom coin optics.
Power up the machine and close the Main Door.
If the error cannot be cleared, the bottom coin optics have to be exchanged.

27 0 - Power up with bill in acceptor

Handling:
Turn/release the attendant key. The bill will be rejected.

45M623N5UK-01

27 1 - Power up with bill in stacker

Handling:
Turn/release the attendant key.
The bill is registered and transported into the stacker.

27 2 - Jam in bill acceptor

07 2008 AGI GmbH

Handling:
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door and power down the machine.
Try to remove the stuck bill. Power up the machine and close the Main Door.
If the error cannot be cleared, the bill acceptor may be disabled to continue the operation of the
game without bill acceptor. To do so, deactivate all bill acceptor channels in the
MACHINE SETUP > BILLS/COINS SETTINGS. Consequently, the bill acceptor has to be
exchanged (
see part V - Bill acceptor).

P a g e
41

GAME & SOFTWARE

27 3 - Jam in stacker

Handling:
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door and power down the machine.
Try to remove the stuck bill. Power up the machine and close the Main Door.
If the error cannot be cleared, the bill acceptor may be disabled to continue the operation of the
game without bill acceptor. To do so, deactivate all bill acceptor channels in the
MACHINE SETUP > BILLS/COINS SETTINGS. Consequently, the bill acceptor has to be
exchanged (
see part V - Bill acceptor).

ATTENTION
The stacker may contain a large amount of bills and the error clearing should be
carried out in a secure area.

27 4 - Bill acceptor disconnected

Handling:
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door and power down the machine.
Check the connectors and the cables of the bill acceptor. Make sure, that the bill acceptor has
been put in place properly. Power up the machine and close the Main Door.
If the error cannot be cleared, the bill acceptor may be disabled to continue the operation of the
game without bill acceptor. To do so, deactivate all bill acceptor channels in the
MACHINE SETUP > BILLS/COINS SETTINGS. Consequently, the bill acceptor has to be
exchanged (
see part V - Bill acceptor).

27 5 - No stacker box

P a g e
42

Handling:
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door and power down the machine.
Check if the stacker box is fixed correctly in its mounting. Furthermore, check the connectors
and the cables of the bill acceptor. Power up the machine and close the Main Door.
If the error cannot be cleared, the bill acceptor may be disabled to continue the operation of the
game without bill acceptor. To do so, deactivate all bill acceptor channels in the
MACHINE SETUP > BILLS/COINS SETTINGS. Consequently, the bill acceptor has to be
exchanged (
see part V - Bill acceptor).

07 2008 AGI GmbH

45M623N5UK-01

GAME & SOFTWARE

27 6 - Bill acceptor cheated

45M623N5UK-01

27 7 - Bill acceptor failure

Handling:
The stacker is full.
Open the Stacker Door and take out the stacker.
Remove the bills, put the stacker in its mounting and close the Stacker Door.
Turn/release the attendant key.

32 00 - Hopper coin out jam

Handling:
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door and power down the machine.
Check if the cables of the bill acceptor and the stacker are connected properly.
Power up the machine and close the Main Door.
If the error cannot be cleared, the bill acceptor may be disabled to continue the operation of the
game without bill acceptor. To do so, deactivate all bill acceptor channels in the
MACHINE SETUP > BILLS/COINS SETTINGS. Consequently, the bill acceptor has to be
exchanged (
see part V - Bill acceptor).

27 8 - Stacker full

Handling:
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door and power down the machine.
Check if the bill acceptor is dirty or damaged and if the connectors and cables are put in place
properly. If necessary, clean the bill acceptor. Check the bill acceptor for any manipulation.
Power up the machine and close the Main Door.
If the error cannot be cleared, the bill acceptor may be disabled to continue the operation of the
game without bill acceptor. To do so, deactivate all bill acceptor channels in the
MACHINE SETUP > BILLS/COINS SETTINGS. Consequently, the bill acceptor has to be
exchanged (
see part V - Bill acceptor).

Handling:
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door.
Check if a coin or dirt is stuck in the light barrier of the hopper ad remove it if necessary.
Close the Main Door. If the error cannot be cleared, the hopper has to be exchanged.

33 00 - Hopper empty

Handling:
Refill the hopper.
Turn the attendant key (to get directly to the Menu Hopper refill), then release the key again.

07 2008 AGI GmbH

P a g e
43

GAME & SOFTWARE

33 0 - Printer is disconnected

Handling:
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door and power down the machine.
Check the connectors and cables of the printer. Make sure, that the printer has been put in place
properly. Power up the machine and close the Main Door.
If the error cannot be cleared, the printer may be disabled in the machine setup to continue the
operation of the game without printer (MACHINE SETUP > PRINTER SETTINGS).
Consequently, the printer has to be exchanged (
see part V - Ticket Printer).

33 1 - Printer is not ready

Handling:
The printer is deactivated.
To use the printer activate it in the MACHINE SETUP > PRINTER SETTINGS.

33 3 - No ticket

Handling:
Turn/release the attendant key.
Check the fill level of the printer. The tickets from the box should be put in the printer properly.
33 4 - Paper jam

33 5 - Error during printing

Handling:
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door and power down the machine.
Try to remove the stuck paper in the printer. Power up the machine and close the Main Door.
If the error cannot be cleared, the printer may be disabled in the machine setup to continue the
operation of the game without printer (MACHINE SETUP > PRINTER SETTINGS).
Consequently, the printer has to be exchanged (
see part V - Ticket Printer).

Handling:
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door and power down the machine.
Check the connectors and the cables of the printer. Make sure that the printer has been put in
place properly. The tickets from the box should be put in the printer properly.
Power up the machine and close the Main Door.
If the error cannot be cleared, the printer may be disabled in the machine setup to continue the
operation of the game without printer (MACHINE SETUP > PRINTER SETTINGS).
Consequently, the printer has to be exchanged (
see part V - Ticket Printer).

34 0 - Hopper disconnected








P a g e
44

Handling:
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door.
Check if the hopper is installed and if both light diodes are illuminated. If the light diodes of the
hopper are not illuminated, check if the hopper is pushed all the way in. Check systematically the
connectors and the cables of the hopper. Power up the machine and close the Main Door.
If the error cannot be cleared, the hopper has to be exchanged (
see part V - Hopper).
07 2008 AGI GmbH

45M623N5UK-01

GAME & SOFTWARE

34 1 - Hopper tilt

34 2 - Hopper low

Handling:
Turn/release the attendant key.
If the error cannot be cleared, open the Main Door and power down the machine.
Check if a coin or dirt is stuck in the light barrier of the hopper and remove it if necessary.
Power up the machine and close the Main Door.
If the error cannot be cleared, the hopper has to be exchanged (
see part V - Hopper).

Handling:
Turn/release the attendant key.
Check the fill level of the hopper. The contact plates on the bottom of the hopper should be
covered with coins. The hopper should be refilled as soon as possible. Check whether the hopper
low level is activated in the software (MACHINE SETUP > HOPPER SETTINGS).

34 4 - Hopper limit reached

Handling:
Indicated on the screen with a special window and registered in the machine log file.
Perform a handpay.

45M623N5UK-01

35 0 - Credit limit reached

Handling:
Indicated on the screen with a special window and registered in the machine log file.
Perform a handpay.

35 1 - LA win limit reached (LA = Legislation Authority)

Handling:
Indicated on the screen with a special window and registered in the machine log file.
Perform a handpay.

35 2 - Jackpot limit reached

Handling:
Indicated on the screen with a special window and registered in the machine log file.
Perform a handpay.

35 3 - Jackpot won

Handling:
Indicated on the screen with a special window and registered in the machine log file.
Perform a handpay.

35 4 - Jackpot limit reached

Handling:
Indicated on the screen with a special window and registered in the machine log file.
Perform a handpay.

07 2008 AGI GmbH

P a g e
45

GAME & SOFTWARE

35 5 - Cash button pressed

Handling:
Indicated on the screen with a special window and registered in the machine log file.
Perform a handpay.

35 7 - Noncash win

Handling:
The won credit is higher than the cashable credit. Perform a handpay.

61

- RAM error

Handling:
Perform a RAM Clear (
see part IV.9 - RAM Clear).
Accounting data can be viewed, but they may be wrong.
If the error cannot be cleared, the mainboard has to be exchanged.

62 0 - ROM CRC error

Handling:
Perform a RAM Clear (
see part IV.9 - RAM Clear).
If the error cannot be cleared, the ROM (game program) has to be exchanged.

63 0 - Logic area was open

45M623N5UK-01

Handling:
Turn/release the attendant key.
63 1 - Logic area open

Handling:
Close the logic area. Turn/release the attendant key.

63 2 - Drop door open

63 4 - Stacker door open

Handling:
Close the Drop Door.
Turn/release the attendant key.
If the error cannot be cleared, check if the Drop Door is fixed correctly in its mounting.
In addition, check the connectors and the cables of the door switch.

Handling:
Close the Stacker Door
Turn/release the attendant key.
If the error cannot be cleared, check if the Stacker Door is fixed correctly in its mounting.
In addition, check the connectors and the cables of the micro switch.

63 5 - Main door optic error





P a g e
46

Handling:
Turn/release the attendant key.
If the error cannot be cleared, the defective door sensor has to be exchanged
(
see part V - Door optics/switches).
07 2008 AGI GmbH

GAME & SOFTWARE

65 0 - Bad EEPROM

Handling:
Turn/release the attendant key.
If the error cannot be cleared, the EEPROM has to be exchanged.

65 1 - EEPROM CRC check failed

Handling:
Turn/release the attendant key.
If the error cannot be cleared, the EEPROM has to be exchanged.

65 2 - EEPROM configuration mismatch

Handling:
Perform a RAM Clear (
see part IV.9 - RAM Clear).
If the error cannot be cleared, the EEPROM and/or the program ROM have to be exchanged.

65 3 - EEPROM structure mismatch

Handling:
Perform a RAM Clear (
see part IV.9 - RAM Clear).
If the error cannot be cleared, the EEPROM and/or the program ROM have to be exchanged.

45M623N5UK-01

65 4 - EEPROM changed

Handling:
Perform a RAM Clear (

68 0 - Program ROM changed

Handling:
Perform a RAM Clear (

see part IV.9 - RAM Clear).

69 0 - Blackbox inoperable

see part IV.9 - RAM Clear).

Handling:
Turn/release the attendant key.
If the error cannot be cleared, check the blackbox connection or exchange the blackbox
and/or the EEPROM.

69 1 - Blackbox CRC check failed

Handling:
Turn/release the attendant key.
If the error cannot be cleared, exchange the blackbox and/or the EEPROM.

76 0 - Digit display not responding

Handling:
Turn/release the attendant key.
If the error cannot be cleared, check the connectors and the cables of the 7 digit display.

07 2008 AGI GmbH

P a g e
47

GAME & SOFTWARE

76 1 - Digit display ROM CRC failed

Handling:
Turn/release the attendant key.
If the error cannot be cleared, check the connectors and the cables of the 7 digit display.

76 2 - Digit display ID CRC failed

Handling:
Turn/release the attendant key.
If the error cannot be cleared, check the connectors and the cables of the 7 digit display.
80 0 - Touch screen missing

80 1 - Touch screen invalid response

Handling:
Turn/release the attendant key.
If the error cannot be cleared, check the connectors and the cables of the touch screen.
Check the power supply of the touch screen.
Exchange the touch screen or the touch screen controller.

80 3 - Touchscreen Controller Error

Handling:
Turn/release the attendant key.
If the error cannot be cleared, check the connectors and the cables of the touch screen.
Check the power supply of the touch screen.
Exchange the touch screen or the touch screen controller.

80 2 - Touch screen invalid checksum

Handling:
Turn/release the attendant key.
If the error cannot be cleared, check the connectors and the cables of the touch screen.
Check the power supply of the touch screen.
Exchange the touch screen or the touch screen controller.

Handling:
Turn/release the attendant key.
If the error cannot be cleared, check the connectors and the cables of the touch screen.
Check the power supply of the touch screen.
Exchange the touch screen or the touch screen controller.

99 9 - Internal Error

P a g e
48

Handling:
Perform a RAM Clear .
If the error cannot be cleared, note down the error message and inform
our Technical Support by phone number +43 2252 606-300.

07 2008 AGI GmbH

45M623N5UK-01

GAME & SOFTWARE

IV.2 Remote in

ATTENTION

In countries where the remote function is prohibited by law this function must not be enabled
and/or has been disabled by the producer.

The assignment of the active buttons in the respective game is shown in the game complement.

How to execute a remote (available only in the idle mode and with closed Main Door):

45M623N5UK-01

1) Turn the attendant key (the machine switches to the AUDIT MENU).

2) Press the active buttons or in case of machines with touchscreen touch the respective fields to
go to the ATTENDANT menu.

3) Select the function REMOTE IN.

07 2008 AGI GmbH

P a g e
49

GAME & SOFTWARE

4) Press the respective buttons or in case of machines with touchscreen touch the respective fields to
add 1, 10, 100 or 1000 credits.
5) The selected credit is registered automatically on the remote meter
(or on the respective country-specific meter).
6) Release the attendant key.
45M623N5UK-01

7) The machine switches back to the game play mode.

The remote function can be used only if it has been enabled in the AUDIT MENU in
MACHINE SETUP > PARAMETER SETTINGS (
see part IV.8 - AUDIT MENU).

P a g e
50

07 2008 AGI GmbH

GAME & SOFTWARE

IV.3 Handpay credit

ATTENTION

In countries where the handpay function is prohibited by law this function must not be enabled
and/or has been disabled by the producer.

The assignment of the active buttons in the respective game is shown in the game complement.

If a limit has been reached during a game, you can get to this page automatically by turning
the attendant key.

How to execute a handpay (available only in the idle mode and with closed Main Door):

45M623N5UK-01

1) Turn the attendant key (the machine switches to the AUDIT MENU).

2) Press the active buttons or in case of machines with touchscreen touch the respective fields to
go to the ATTENDANT menu.

07 2008 AGI GmbH

P a g e
51

GAME & SOFTWARE

3) Select the function HANDPAY CREDIT.

4) Press the respective buttons or in case of machines with a touchscreen touch the respective fields
to handpay the current credit.
5) The handpaid credit is registered automatically on the handpay meter.
6) Release the attendant key.
45M623N5UK-01

7) The machine switches back to the game play mode.

The handpay function can only be used if it has been enabled in the AUDIT MENU in
MACHINE SETUP > PARAMETER SETTINGS (
see part IV.8 - AUDIT MENU).

P a g e
52

07 2008 AGI GmbH

GAME & SOFTWARE

IV.4 Hopper refill


The assignment of the active buttons in the respective game is shown in the game complement.

How to refill the hopper (available only in the idle mode):


1) Open the Main Door and refill the respective number of coins into the hopper.

45M623N5UK-01

1) Turn the attendant key (the machine switches to the AUDIT MENU).

3) Press the active buttons or in case of machines with touchscreen touch the respective fields to
go to the ATTENDANT menu.

4) Select the function HOPPER REFILL.

07 2008 AGI GmbH

P a g e
53

GAME & SOFTWARE

5) Press the active buttons or touch the respective fields to enter the sum of the refilled amount
of coins.
6) The refilled amount is registered automatically. This amount must exactly relate to the coins refilled,
otherwise the accounting will be incorrect.

7) Close the Main Door.


45M623N5UK-01

8) Release the attendant key.


9) The machine switches back to the game play mode.

P a g e
54

07 2008 AGI GmbH

GAME & SOFTWARE

IV.5 Hopper dump

ATTENTION

In countries where the hopper dump function is prohibited by law, this function must not be enabled
and/or has been disabled by the producer.

The assignment of the active buttons in the respective game is shown in the game complement.

How to dump the hopper (available only in the idle mode):


1) Open the Main Door.

45M623N5UK-01

2) Turn the attendant key (the machine switches to the AUDIT MENU).

3) Press the active buttons or in case of machines with touchscreen touch the respective fields
to go to the ATTENDANT menu.

4) Select the function HOPPER DUMP.

07 2008 AGI GmbH

P a g e
55

GAME & SOFTWARE

5) Press the active buttons or touch the respective fields to enter the sum of the amount to dump
in steps of 1, 10 or 100.
6) The dumped amount is registered automatically.
7) Close the Main Door.

45M623N5UK-01

8) Release the attendant key.


9) The machine switches back to the game play mode.

P a g e
56

07 2008 AGI GmbH

GAME & SOFTWARE

IV.6 Out of Service (Locking of the machine)




This function allows the attendant to lock the machine for the game play mode while it is switched on.
By using the Out of Service function it is not necessary to power down a defective machine but it may be
locked as long as the defect has not been repaired.

The assignment of the active buttons in the respective game is shown in the game complement.

How to put the machine out of service:

45M623N5UK-01

1) Turn the attendant key (the machine switches to the AUDIT MENU).

2) Press the active buttons or in case of machines with touchscreen touch the respective fields
to go to the ATTENDANT menu.

3) Select the function OUT OF SERVICE: INACTIVE.

07 2008 AGI GmbH

P a g e
57

GAME & SOFTWARE

4) Press the active button or touch the field Enter to lock the machine.

5) Release the attendant key.


6) The machine switches back to the game play mode. On the screen a message is displayed containing

45M623N5UK-01

the information, that the machine is out of service.

7) To unlock the machine, turn and release the attendant key.


The machine is now enabled for gambling.

P a g e
58

07 2008 AGI GmbH

GAME & SOFTWARE

45M623N5UK-01

IV.7 Top light


The top light indicates the different operational status (jackpot, error, service, etc.).

Novomatic Standard

Blue is lighting:

The SERVICE button has been pressed.

White is flashing fast:

The machine is in the idle mode and the Main Door or


the Door-in-Door system is open.

The light is flashing until the fist game has been finished.

Blue is flashing slowly:

Error - the machine is not ready for play.

The error message is shown on the screen


(
see part IV.1 - Error handling).

Blue is flashing slowly, white is flashing fast:

Error - the machine is not ready for play.

The error message is indicated in case of error and the Main Door
or the Door-in-Door system is open.

Blue and white are flashing slowly:

Handpay is required.
After the handpay has been finished the lamps stop flashing.

07 2008 AGI GmbH

P a g e
59

GAME & SOFTWARE

Bally France

Green is flashing:

A limit has been reached.


After the handpay has been finished the lamps stop flashing.

Red is lighting:

Error - the machine is not ready for play.

The error message is shown on the screen


(
see part IV.1 - Error handling).

Red is flashing:

The Main Door or the Door-in-Door system is open.

Yellow is flashing:

The SERVICE button has been pressed.

P a g e
60

45M623N5UK-01

07 2008 AGI GmbH

GAME & SOFTWARE

IV.8 Audit Menu


INFORMATION

Depending on machine configuration the items described in this part may vary.

INFORMATION

The respective active buttons (illuminated) are located on the keyboard below the control panel
shown on the screen. See game supplement.

IV.8.1

ATTENDANT Menu

45M623N5UK-01

Turn the attendant key to enter the ATTENDANT menu. This menu shows the accounting and statistic,
and several settings may be made. The pages can be selected by pressing the active buttons or in case of
machines with touchscreen by touching the respective fields.

The left illustration shows the AUDIT MENU at closed Main Door, the right illustration shows the extended
AUDIT MENU at opened Main Door.

07 2008 AGI GmbH

P a g e
61

GAME & SOFTWARE

ATTENDANT > REMOTE IN

Press the respective buttons or in case of machines with a touchscreen touch the respective fields to add
the desired amount (
see part IV.2 - Remote in).
The respective value and registered credit of each payment transaction are indicated.
Shows the credit added via the remote function.

CURRENT CREDIT

Shows the current credit.


45M623N5UK-01

REMOTE IN

P a g e
62

07 2008 AGI GmbH

GAME & SOFTWARE

45M623N5UK-01

ATTENDANT > HANDPAY CREDIT

CURRENT HANDPAY

Press the respective buttons or in case of machines with a


touchscreen touch the respective fields to handpay the current
credit (
see part IV.3 - Handpay credit).

CASHABLE CREDIT
FROM COIN
FROM BILL
FROM TICKET
TICKET SEMIPROMOTIONAL
SEMIPROMOTIONAL
CASHABLE

BANK

Indicates the total amount of all cashable credits.


Proportion of the cashable credit entered in coins.
Proportion of the cashable credit entered in bills.
Proportion of the cashable credit entered in tickets.
Proportion of the cashable credit entered in promotional tickets.
Proportion of the cashable credit entered via online system.
Proportion of the cashable credit which is not assignable to the
above mentioned credit types (e.g. remote).
Credit cashable from the bank display.

NONCASHABLE CREDIT

FROM TOKEN
TICKET PROMOTIONAL
TICKET NONCASHABLE
PROMOTIONAL
NONCASHABLE

Indicates the total amount of all non-cashable credits.


Non-cashable credits have to be gambled away!
Proportion of the non-cashable credit entered in tokens.
Proportion of the non-cashable credit entered in promotional tickets.
Proportion of the non-cashable credit entered in tickets.
Proportion of the non-cashable credit entered via online system.
Proportion of the non-cashable credit which is not assignable to the
above mentioned credit types.

ATTENTION

For each transaction, the monetary value and the corresponding credit amount are indicated.
Which kind of credit is deemed CASHABLE or NONCASHABLE may vary depending on the
jurisdiction.

07 2008 AGI GmbH

P a g e
63

GAME & SOFTWARE

ATTENDANT > HOPPER REFILL

Total value of all coins available in the hopper.


Total value of all coins available in the hopper for a certain period.
Indicates the hopper defined refill level.
Coins still missing for the hopper refill level set.
Enter the amount filled in the hopper by using the respective buttons
or the respective touchscreen fields
(
see part IV.4 - Hopper refill).

The number of coins, the respective value and the respective registered credit of each payment transaction
are indicated.

ATTENDANT > HOPPER DUMP

TOTAL HOPPER LEVEL


PERIODIC HOPPER LEVEL
HOPPER DUMP

Total value of all coins available in the hopper.


Total value of all coins available in the hopper for a certain period.
Press the respective buttons or the respective touchscreen fields to
enter the amount to dump the hopper
(
see part IV.5 - Hopper dump).

The number of coins, the respective value and the respective registered credit of each payment transaction
are indicated.
P a g e
64

07 2008 AGI GmbH

45M623N5UK-01

TOTAL HOPPER LEVEL


PERIODIC HOPPER LEVEL
HOPPER REFILL LEVEL
MISSING AMOUNT
HOPPER REFILL

GAME & SOFTWARE

45M623N5UK-01

ATTENDANT > OUT OF SERVICE

This function allows the attendant to lock the machine for the game play mode while it is switched on
(
see part IV.6 - Out of Service).

07 2008 AGI GmbH

P a g e
65

GAME & SOFTWARE

IV.8.2 ACCOUNTING Menu

45M623N5UK-01

ACCOUNTING > MASTER ACCOUNTING

TOTAL IN

COINS IN
TOKEN IN
BILL IN
REMOTE IN
CARD IN
TICKET IN

Total value of all coins, tokens, tickets and bills inserted and credits added
via the remote function.
Total value of all coins inserted via the coin acceptor.
Total value of all tokens accepted.
Total value of all bills accepted.
Total value of all credits added via the remote function.
Total value of all credits inserted via cashless card.
Total value of all credits inserted via ticket.

TOTAL OUT
COINS OUT
HANDPAY
CARD OUT
TICKET OUT

Total value of all credits paid out (hopper, handpay, card and vouchers).
Total value of all coins paid out via the hopper.
Total value of all amounts paid out via handpay function.
Total value of credits added to the cashless card.
Total value of credits paid out via ticket printer.

TOTAL IN-OUT

Difference between TOTAL IN and TOTAL OUT.

The respective value and the respective registered credit of the payment transaction are indicated.
P a g e
66

07 2008 AGI GmbH

45M623N5UK-01

GAME & SOFTWARE

TOTAL MONEY TO DROP


COINS TO DROP
TOKENS TO DROP
BILLS TO DROP

Total value of all coins and bills that can be removed.


Total value of all coins that can be removed from the drop box.
Total value of all tokens that can be removed.
Total value of all bills that can be removed from the stacker box.

TOTAL HOPPER LEVEL


COINS TO HOPPER
COINS OUT
HOPPER REFILL
HOPPER DUMP

Total value of all coins available in the hopper.


Total value of all coins diverted into the hopper via the coin acceptor.
Total value of all coins paid out via the hopper.
Total value of all coins refilled directly to the hopper.
Total value of all coins paid out via the hopper with the
hopper dump function.

TOTAL BET
TOTAL WON

Total value of all bets.


Total value of all wins.

MACHINE YIELD
TOTAL GAMES

Payout percentage.
Total number of all games played.

The respective value and the respective registered credit of the payment transaction are indicated.

07 2008 AGI GmbH

P a g e
67

TICKET IN
CASHABLE
NONCASHABLE
PROMOTIONAL

Total value of tickets accepted by the bill acceptor.


Cashable tickets accepted by the bill acceptor.
Non-cashable tickets accepted by the bill acceptor.
Promotional tickets accepted by the bill acceptor.

TICKET OUT
CASHABLE
NONCASHABLE
PROMOTIONAL

Total value of tickets paid out via the ticket printer.


Cashable tickets paid out via the ticket printer.
Non-cashable tickets paid out via the ticket printer.
Promotional tickets paid out via the ticket printer.

Furthermore, the TOTAL NUMBER OF ACCEPTED TICKETS and the TOTAL NUMBER OF PRINTED
TICKETS are indicated on this page.
The respective value and the respective registered credit of the payment transaction are indicated.

P a g e
68

07 2008 AGI GmbH

45M623N5UK-01

GAME & SOFTWARE

45M623N5UK-01

GAME & SOFTWARE

HANDPAY
CANCELLED CREDITS
WIN LIMIT JACKPOT
PROGRESSIVE JACKPOT
MYSTERY JACKPOT

Total value of all handpays.


Total value of all credits cancelled via handpay function.
Total value of all handpaid jackpot wins.
Total value of all handpaid external jackpots.
Total value of all handpaid mystery jackpots.

TOTAL WIN
WIN TO CREDIT
JP WIN TO CREDIT
WIN TO HANDPAY
WIN TO CARD
WIN TO TICKET

Total value of all wins.


Total value of all wins added to credit.
Total value of all jackpot wins added to credit.
Total value of all handpaid wins.
Total value of all wins transferred to the cashless card.
Total value of all wins paid out via Ticket Printer.

TOTAL BONUS
DEDUCT. BONUS
NON DEDUCT. BONUS
WAGER M. BONUS

Total value of the additional win option (bonusing system via network).
Tax-deductible part of the bonusing system.
Non-deductible part of the bonusing system.
Wager according to bonusing system.

The respective value and the respective registered credit of the payment transaction are indicated.

07 2008 AGI GmbH

P a g e
69

GAME & SOFTWARE

Indicates the available bill channels.


Value of one bill of the respective bill channel.
Total number of bills accepted on the respective bill channel.
Total number of credits inserted via the respective bill channel.
Total value of all credits inserted via the respective bill channel.

CHANNEL
VALUE ()
COUNT
CREDIT
TOTAL ()

Indicates the available coin channels.


Value of one coin of the respective coin channel.
Total number of coins accepted via the respective coin channel.
Total number of credits inserted via the respective coin channel.
Total value of credits inserted via the respective coin channel.

45M623N5UK-01

CHANNEL
VALUE ()
COUNT
CREDIT
TOTAL ()

P a g e
70

07 2008 AGI GmbH

45M623N5UK-01

GAME & SOFTWARE

CHANNEL
VALUE ()
COUNT
CREDIT
TOTAL ()

Indicates the available hopper channels.


Value of one coin of the respective hopper channel.
Total number of coins accepted on the respective hopper channel.
Total number of credits inserted via the respective hopper channel.
Total value of all credits inserted via the respective hopper channel.

COINS TO HOPPER
HOPPER REFILL
HOPPER DUMP
HOPPER LEVEL

Total amount of coins transported into the hopper.


Total amount of coins refilled into the hopper.
Total amount of coins removed from the hopper.
Total value of all coins available in the hopper.

07 2008 AGI GmbH

P a g e
71

GAME & SOFTWARE

ACCOUNTING > PERIODIC ACCOUNTING

Total value of all coins, tickets, tokens and bills inserted and credits added
via the remote function for a certain period.
Total value of all coins inserted via the coin acceptor for a certain period.

TOKEN IN
BILL IN
REMOTE IN
CARD IN
TICKET IN

Total value of all tokens accepted for a certain period.


Total value of all bills accepted for a certain period.
Total value of all credits added via the remote function for a certain period.
Total value of all credits added via card for a certain period.
Total value of all credits inserted via ticket for a certain period.

PERIODIC OUT

Total value of all credits paid out for a certain period.

COINS OUT
HANDPAY
CARD OUT
TICKET OUT

Total value of all coins paid out via the hopper for a certain period.
Total value of all credits paid out via the handpay function for a certain period.
Total value of all credits added to the cashless card for a certain period.
Total value of all credits paid out via ticket printer for a certain period.

PERIODIC IN-OUT

Difference between TOTAL IN and TOTAL OUT for a certain period.

The respective value and the respective registered credit of each payment transaction are indicated.

P a g e
72

07 2008 AGI GmbH

45M623N5UK-01

PERIODIC IN

COINS IN

GAME & SOFTWARE

PERIODIC MONEY TO DROP


COINS TO DROP

TOKENS TO DROP

Total value of all coins and bills that can be removed in a certain period.
Total value of all coins that can be removed from the drop box in a
certain period.
Total value of all tokens that can be removed for a certain period.

PERIODIC HOPPER LEVEL


COINS TO HOPPER

COINS OUT

Total value of all coins available in the hopper for a certain period.
Total value of all coins diverted into the hopper via the coin acceptor in
a certain period.
Total value of all coins paid out via the hopper in a certain period.

45M623N5UK-01

BILLS TO DROP

Total value of all bills that can be removed from the stacker box in a
certain period.

HOPPER REFILL
HOPPER DUMP

Total value of all coins refilled directly into the hopper in a certain period.
Total value of all coins paid out via the hopper with the hopper dump
function in a certain period.

PERIODIC BET
PERIODIC WON

Total value of all bets in a certain period.


Total value of all wins realized in a certain period.

MACHINE YIELD
PERIODIC GAMES

Payout percentage for a certain period.


Total number of games played in a certain period.

The respective value and the respective registered credit of each payment transaction are indicated.

07 2008 AGI GmbH

P a g e
73

TICKET IN
CASHABLE
NONCASHABLE
PROMOTIONAL

Total value of all tickets accepted in a certain period.


Total value of cashable tickets accepted in a certain period.
Total value of non-cashable tickets accepted in a certain period.
Total value of promotional tickets accepted in a certain period.

TICKET OUT
CASHABLE
NONCASHABLE

PROMOTIONAL

Total value of all tickets paid out via the ticket printer in a certain period.
Total value of cashable tickets paid out via the ticket printer in a certain period.
Total value of non-cashable tickets paid out via the ticket printer in a
certain period.
Total value of promotional tickets paid out via the ticket printer in a
certain period.

Furthermore, the TOTAL NUMBER OF ACCEPTED TICKETS in certain period and the TOTAL NUMBER
OF PRINTED TICKETS in a certain period are indicated on this page.
The respective value and the respective registered credit of each payment transaction are indicated.

P a g e
74

07 2008 AGI GmbH

45M623N5UK-01

GAME & SOFTWARE

45M623N5UK-01

GAME & SOFTWARE

HANDPAY
CANCELLED CREDITS

WIN LIMIT JACKPOT
PROGRESSIVE JACKPOT
MYSTERY JACKPOT

Total value of all handpays in a certain period.


Total value of all credits cancelled via handpay function in a certain
period.
Total value of all handpaid jackpot wins in a certain period.
Total value of all handpaid external jackpots in a certain period.
Total value of all handpaid mystery jackpots in a certain period.

TOTAL WIN
WIN TO CREDIT
JP WIN TO CREDIT
WIN TO HANDPAY
WIN TO CARD

WIN TO TICKET

Total value of all wins in a certain period.


Total value of all wins added to credit in a certain period.
Total value of all jackpot wins added to credit in a certain period.
Total value of all handpaid wins in a certain period.
Total value of all wins transferred to the cashless card in a certain
period.
Total value of all wins paid out via Ticket Printer in a certain period.

TOTAL BONUS

DEDUCT. BONUS
NON DEDUCT. BONUS
WAGER M. BONUS

Total value of the additional win option (bonusing system via network)
in a certain period.
Tax-deductible part of the bonusing system in a certain period.
Non-deductible part of the bonusing system in a certain period.
Wager according to bonusing system in a certain period.

The respective value and the respective registered credit of the payment transaction are indicated.

07 2008 AGI GmbH

P a g e
75

GAME & SOFTWARE

CHANNEL
VALUE ()
COUNT
CREDIT

Indicates the available bill channels.


Value of one bill of the respective bill channel.
Total number of bills accepted via the respective bill channel in a certain period.
Total number of credits inserted via the respective bill channel in a certain period.

Total value of credits inserted via the respective bill channel in a certain period.

CHANNEL
VALUE ()
COUNT
CREDIT
TOTAL ()

Indicates the available coin channels.


Value of one coin of the respective coin channel.
Total number of coins accepted via the respective coin channel in a certain period.
Total number of credits inserted via the respective coin channel in a certain period.
Total value of credits inserted via the respective coin channel in a certain period.

45M623N5UK-01

TOTAL ()

P a g e
76

07 2008 AGI GmbH

GAME & SOFTWARE

CHANNEL
VALUE ()
COUNT

CREDIT

Indicates the available hopper channels.


Value of one coin of the respective hopper channel.
Total number of coins accepted via the respective hopper channel
in a certain period.
Total number of credits inserted via the respective hopper channel

COINS TO HOPPER
HOPPER REFILL
HOPPER DUMP

Total amount of coins transported into the hopper in a certain period.


Total amount of coins refilled into the hopper in a certain period.
Total amount of coins removed from the hopper in a certain period.

45M623N5UK-01


TOTAL ()

HOPPER LEVEL

07 2008 AGI GmbH

in a certain period.
Total value of credits inserted via the respective hopper channel
in a certain period.

Total number of coins available in the hopper in a certain period.

P a g e
77

GAME & SOFTWARE

ACCOUNTING > HARD METER COPY

This page is an exact copy of the mechanical meters.


The pin assignment of the meters is country-specific.

P a g e
78

Total value of all bets in credits.


Total value of all wins in credits.
Total value of all credits added via remote function.
Total value of all credits paid out via handpay function.
Total value of all bills inserted in credits.
Total value of all coins inserted into the drop box in credits.
Total number of all games played.
Total value of all tokens inserted in credits.

45M623N5UK-01

BET
WIN
REMOTE
HANDPAY
BILLS
DROP
GAMES
TOKEN

ATTENTION

After a RAM Clear the parameters are 0 again!

07 2008 AGI GmbH

GAME & SOFTWARE

45M623N5UK-01

ACCOUNTING > SECURITY ACCOUNTING

MAIN DOOR
LAST OPEN
LAST CLOSE
OPEN COUNT
GAMES SINCE LAST CLOSE

Monitored status.
Date and time of last opening of the Main Door.
Date and time of last closing of the Main Door.
Number of openings of the Main Door.
Number of games played since last closing of the Main Door.

DOOR IN DOOR
LAST OPEN
LAST CLOSE
OPEN COUNT
GAMES SINCE LAST CLOSE

Monitored status.
Date and time of last opening of the Door-in-Door.
Date and time of last closing of the Door-in-Door.
Number of openings of the Door-in-Door.
Number of games played since last closing of the Door-in-Door.

COIN DROP DOOR


LAST OPEN
LAST CLOSE
OPEN COUNT
GAMES SINCE LAST CLOSE

Monitored status.
Date and time of last opening of the Drop Door.
Date and time of last closing of the Drop Door.
Number of openings of the Drop Door.
Number of games played since last closing of the Drop Door.

07 2008 AGI GmbH

P a g e
79

BILL DOOR
LAST OPEN
LAST CLOSE
OPEN COUNT
GAMES SINCE LAST CLOSE

Monitored status.
Date and time of last opening of the Stacker Door.
Date and time of last closing of the Stacker Door.
Number of openings of the Stacker Door.
Number of games played since last closing of the Stacker Door.

LOGIC AREA
POWER ON AFTER OPEN
OPEN COUNT
GAMES SINCE LAST CLOSE

Monitored status.
Date and time of last opening of the Logic Door.
Number of openings of the Door-in-Door.
Number of games played since last closing of the Logic Door.

METER CONNECT
LAST OPEN
LAST CLOSE
OPEN COUNT
GAMES SINCE LAST CLOSE

Monitored status.
Date and time of last disconnection of the mechanical meters.
Date and time of last connection of the mechanical meters.
Number of disconnections of the mechanical meters.
Number of games played since last connection of the
mechanical meters.

P a g e
80

07 2008 AGI GmbH

45M623N5UK-01

GAME & SOFTWARE

GAME & SOFTWARE

POWER FAIL
LAST POWER FAIL
LAST POWER ON
POWER FAIL COUNT
GAMES SINCE LAST POWER FAIL

Monitored status.
Date and time of last power down.
Date and time of last power on.
Number of power downs.
Number of games played since last power down interruption.

45M623N5UK-01

ACCOUNTING > PERIODIC METER CLEAR

PRESS CLEAR BUTTON TO CLEAR PERIODIC RAM


Press the respective button or the respective touchscreen field to clear the periodic RAM.

07 2008 AGI GmbH

P a g e
81

GAME & SOFTWARE

IIV.8.3

DIAGNOSTIC Menu

45M623N5UK-01

DIAGNOSTIC > PROGRAM VERSIONS

MACHINE NUMBER
MACHINE
EEPROM CONFIGURATION
KERNEL
MAINBOARD VERSION
MAINBOARD SERIAL NUMBER
BACKPLANE VERSION
GAME

P a g e
82

Indicates the configured machine number.


Indicates name, version and date of the complete machine software.
Indicates the EEPROM configuration.
Indicates version and date of the kernel.
Indicates the version of the mainboard.
Indicates the serial number of the mainboard.
Indicates the version of the backplane.
Indicates the name, version and date of the game.

07 2008 AGI GmbH

GAME & SOFTWARE

DIAGNOSTIC > DEVICE LISTING

Indicates the machine components which are recognized by the software.


The number and the form of the entries depends on the current equipment of the machine (bill acceptor,
ticket printer, etc.).

45M623N5UK-01

DIAGNOSTIC > MACHINE SELFTEST

Press Test button to start selftest


Press the respective button or touch the respective touchscreen field to start the selftest.
After the selftest is completed, a detailed listing of the tested devices is indicated.
07 2008 AGI GmbH

P a g e
83

GAME & SOFTWARE

45M623N5UK-01

DIAGNOSTIC > BUTTON AND LAMP TEST

LAMP TEST
BUTTON TEST

All lamps are flashing steadily as long as this page is enabled.


The current status of the buttons (ON/OFF) is indicated.

To go back, press HOLD 1 and HOLD 2 simultaneously


Press the respective buttons to return to the DIAGNOSTIC menu.

P a g e
84

07 2008 AGI GmbH

GAME & SOFTWARE

DIAGNOSTIC > VIDEO TEST

Select the function VIDEO TEST to show the test chart on the screen.
In case of eventual distortions or a defective colour reproduction the monitor can be readjusted according
to this test chart.

45M623N5UK-01

DIAGNOSTIC > AUDIO TEST

Press the respective buttons or touch the respective fields to start the audio test.
07 2008 AGI GmbH

P a g e
85

GAME & SOFTWARE

DIAGNOSTIC > TOUCH SCREEN TEST

Select the function TOUCH SCREEN TEST to check the calibration and functionality of the touchscreen.
Touch the screen at different places. At each touch a white point is enlightened on the screen.

45M623N5UK-01

DIAGNOSTIC > HOPPER TEST

Select the function HOPPER TEST to check the functionality of the hopper.
Follow the instructions indicated on the screen. Coins inserted are not registered!
P a g e
86

07 2008 AGI GmbH

GAME & SOFTWARE

DIAGNOSTIC > BILL ACCEPTOR TEST

The BILL ACCEPTOR TEST function can be used to check the functionality of the bill acceptor.

45M623N5UK-01

ATTENTION

If a bill is not detected, the reason may be that the insertion direction is not enabled in the menu item
MACHINE > BILL SETTINGS or the software is not programmed to accept the bill.

DIAGNOSTIC > COIN DIVERTER TEST

Select the function COIN DIVERTER TEST to test the functionality of the coin diverter.
Press the respective button or touch the respective field to switch the coin diverter ON or OFF.

07 2008 AGI GmbH

P a g e
87

GAME & SOFTWARE

IV.8.4

EVENT LOG Menu

45M623N5UK-01

EVENT LOG > MACHINE EVENTS

All errors including date and time when they have occurred are listed.
The error codes and error messages correspond to those listed in part IV.1.2.
In case of an overflow the respective oldest entries are overwritten.

P a g e
88

07 2008 AGI GmbH

GAME & SOFTWARE

EVENT LOG > BILL ACCEPTOR EVENTS

All accepted bills including date and time of their insertion are listed.
In case of an overflow the respective oldest entries are overwritten.

45M623N5UK-01

EVENTS > HANDPAY EVENTS

Lists all handpay events including date and time when they where paid out.
In case of an overflow the respective oldest entries are overwritten.

07 2008 AGI GmbH

P a g e
89

GAME & SOFTWARE

EVENT LOG > CASHLESS CARD EVENTS

All accepted card credits including date and time are listed.
In case of an overflow the respective oldest entries are overwritten.

45M623N5UK-01

EVENTS > JACKPOT EVENTS

Lists all external jackpots including date and time when they where hit.
In case of an overflow the respective oldest entries are overwritten.

P a g e
90

07 2008 AGI GmbH

GAME & SOFTWARE

EVENT LOG > TICKET OUT

Lists all ticket events including validation number, value, ticket number, date and time.
In case of an overflow the respective oldest entries are overwritten.

45M623N5UK-01

EVENTS > TICKET IN

Lists all ticket events including validation number, value, ticket number, date and time.
In case of an overflow the respective oldest entries are overwritten.

07 2008 AGI GmbH

P a g e
91

GAME & SOFTWARE

IV.8.5

GAME HISTORY Menu

GAME HISTORY

Game history of the selected game.


Current number of the game at a certain time.
Phase during the indicated game (1st deal is phase 1,
2nd deal is phase 2, etc.), depending on the indicated game.

Date
Time

Indicates the date of the game.


Indicates the time of the game.

Credit bef.
Bet
Win

Amount of credit before the game was started.


Bets realized in credits.
Wins in credits.

Gambles
Gamble in
Gamble out

Number of times gambled.


Value of wins which has been gambled.
Value of wins which has been paid out after gamble.

SINCE LAST GAME


Tokens in
Coins in
Bills in
Remote in
Card in
Bonus in
Ticket in
Collected

Total value of tokens inserted since last game.


Total value of coins inserted since last game.
Total value of bills inserted since last game.
Total value of all credits added via the remote function since last game.
Total value of all credits added via card since last game.
Total value of all credits added via online system since last game.
Total value of all credits inserted via tickets since last game.
Total value of all credits paid out via the hopper and the handpay function
since last game.

P a g e
92

45M623N5UK-01

GAME HISTORY
Game
Phase

07 2008 AGI GmbH

GAME & SOFTWARE

IV.8.6

GAME STATISTIC Menu

45M623N5UK-01

GAME STATISTIC > Selected Game

The game statistic depend on the selected game. If different bets (BET) are permitted in the game, the
first page always indicates the total statistic (BET - independent) and each BET available is represented
separately (e.g. page 2 = BET 1, page 3 = BET 2, etc.).

07 2008 AGI GmbH

P a g e
93

GAME & SOFTWARE

IV.8.7

GAME SETUP Menu

45M623N5UK-01

GAME SETUP > Selected Game

On this page several functions specific to the selected game can be featured.

P a g e
94

07 2008 AGI GmbH

GAME & SOFTWARE

IV.8.8

MACHINE SETUP Menu

45M623N5UK-01

MACHINE SETUP > LIMIT SETUP

INFORMATION

In comparison to the CREDIT LIMIT the CREDIT IN LIMIT must always be lower by AT LEAST the value
represented by the highest configuration bill (coin, token).
This ensures that by insertion of a bill (coin, token) only the CREDIT IN LIMIT may be reached and never
the CREDIT LIMIT.

CREDIT IN LIMIT


0...

If the limit has been reached, no more credits can be added (coin and
bill acceptor are blocked), also the remote function is disabled.
No CREDIT IN LIMIT.

CREDIT LIMIT


0...

Maximum credit value that may be reached in the game.


If the limit has been reached, a handpay is required.
No CREDIT LIMIT.

JACKPOT LIMIT


0...

Maximum value of win paid out by the machine (added to credit or


paid out via the hopper).
No JACKPOT LIMIT.

07 2008 AGI GmbH

P a g e
95

CELEBRATION LIMIT

Available only in cashless card systems.


If this limit is reached (under jackpot limit), a handpay to the cashless
card has to be performed!

DOUBLE UP LIMIT

Maximum credit value that may be reached in the double-up game.

HOPPER PAYOUT LIMIT





0...

Maximum number of coins that can be paid out via the hopper, if the
CASH button has been pressed or in case of wins. All amounts in
excess have to be paid out via the handpay function.
No HOPPER LIMIT.

TICKET PAYOUT LIMIT




0...

Maximum amount that can be paid out via the ticket printer.
All amounts in excess have to be paid out via the handpay function.
No TICKET LIMIT.

COINS IN LIMIT


0...

Indicates the number of coins that can be inserted without a game


played.
No COIN IN LIMIT.

MINIMUM HANDPAY

Minimum amount of win paid out via handpay.

EVEN HANDPAY

Indicates the rounding factor for handpay.


For example: if 50 is set, 1750 are paid instead of 1755, the
remaining 5 continue on the credit.

Press the corresponding buttons or touch the respective fields to perform the desired settings.
In each case a MIN and a MAX value are indicated in the range of which the current value can be set.
Due to regulation some value ranges may be limited or the possibility of setting may be prohibited
in general.

P a g e
96

07 2008 AGI GmbH

45M623N5UK-01

GAME & SOFTWARE

GAME & SOFTWARE

MACHINE SETUP > PARAMETER SETUP

Press the corresponding buttons or touch the respective fields to perform the desired settings.

INFORMATION

45M623N5UK-01

Depending on the game configuration and the game some of the following functions listed below may not
be available!

START MODE
0... RE-BET AT START

1... BET AND START

2... AUTOSTART

Determines the start mode.


If credits are available and the START button is pressed,
a game is started with the last bet.
A bet must be selected and the START button must be
pressed to start the game.
If credits are available, the START button has to pressed to
play a game or if the AUTOSTART button is pressed, a game
will be automatically started with the last bet.

REMOTE INPUT
0... DISABLED
1... ENABLED

Enables/disables the remote function.


The remote function is disabled.
The remote function is enabled.

HANDPAY CREDIT
0... DISABLED
1... ENABLED

Enables/disables the handpay function.


The handpay function is disabled.
The handpay function is enabled.

BILL INPUT
0... TO HOPPER

1... TO CREDIT
2... TO CREDIT/COMPULSORY GAME

3... TO CREDIT/PLAY 50%

Determines the bill accounting.


Bills are changed. The highest bill must be lower than the
hopper limit.
The value of inserted bills is added to the credit.
Bills inserted are added to the credit and a compulsory game
must be played before the system accepts a new bill.
Bills inserted are added to the credit. A minimum of 50 % of
the value of each inserted bill must be played before the
system accepts a new bill.

07 2008 AGI GmbH

P a g e
97

GAME & SOFTWARE

Determines the coin accounting.


Coins are registered on the CREDITS PLAYED meter until the maximum
bet is reached. A game is not started automatically unless the MAX BET
button is pressed.
Coins are registered on the CREDITS PLAYED meter until the maximum
bet is reached. The game starts automatically.
Coins are registered on the CREDITS PLAYED meter until the maximum
bet is reached - any subsequent coins are registered on the CREDIT meter.
A game is not started automatically unless the MAX BET button is pressed.
Coins are registered on the CREDIT meter. A game is not started
automatically unless the MAX BET button is pressed and enough credits
are available.
Coins are registered on the CREDIT meter.
No game can be started with the MAX BET button.

WIN OUTPUT
0... TO HOPPER
1... TO CREDIT

Determines the accounting of the wins.


All wins are paid out via the hopper.
All wins are registered on the CREDIT meter.

PAY AT JACKPOT LIMIT


0... WIN
1... WIN + CREDIT

Determines the way jackpots are handled.


Only the win is paid.
The win and the credit is paid.

PAY AT CREDIT LIMIT


0... WIN
1... WIN + CREDIT

Determines the way the credit limit is handled.


Only the win is paid.
The win and the credit is paid.

PARTIAL PAY MODE


0... NO PARTIAL HANDPAY
1... PARTIAL HANDPAY

Determines whether a partial payout can be made.


Partial payouts cannot be made. The entire amount must be handpaid.
System allows partial payout. The hopper pays coins until the
hopper limit is reached, the remaining amount must be handpaid.

HOPPER REMAINDER
0... TO CREDIT
1... TO HANDPAY
2... CREDIT + HANDPAY

Determines the way that non-cashable credits are handled.


Remaining amounts remain on the CREDIT meter.
Remaining amounts must be handpaid.
Remaining amounts remain on the CREDIT meter. After pressing the
CASH button a handpay of the remaining amount is offered.

LANGUAGE
0... ENGLISH
1... GERMAN
2... SPANISH
3... PORTUGUESE

Setting of the language.


4... FRENCH
5... NORWEGIAN
6... HUNGARIAN

P a g e
98

45M623N5UK-01

COIN INPUT
0... TO BET


1... TO BET/START

2... TO BET/TO CREDIT


3... TO CREDIT


4... TO CREDIT/CANCEL

07 2008 AGI GmbH

45M623N5UK-01

GAME & SOFTWARE

HOPPER DUMP
0... DISABLED
1... ENABLED

Enables/disables the hopper dump function.


Hopper dump is disabled.
Hopper dump is enabled.

HOPPER STRATEGY
0... HIGH VALUE + RETRY

1... HIGH VALUE

2... BALANCED

Determines the way payout is handled when two hoppers are used.
If the first hopper is already empty, the machine switches over to the
second hopper for payout.
High-value coins are preferred for payout, the remaining amount is
paid out in lower-value coins.
Wins are paid out with a balanced number of both high-value and
low-value coins.

WINCOUNTER SPEED
0... SLOW
1... FAST

Determines the win counting speed.


Win counting is slow.
Win counting is fast.

BILL ACCEPTOR SECURITY



0... OFF
1... 10 REJECTED
2... 5 REJECTED

Activates/deactivates disabling of the bill acceptor after insertion of


a bill failed.
The bill acceptor is never disabled.
The bill acceptor is disabled after 10 attempts failed.
The bill acceptor is disabled after 5 attempts failed.

BONUSING
0... DISABLED
1... ENABLED

Enables/disables a network bonus system.


The bonus is not accepted.
The bonus is accepted.

TICKET REDEMPTION
0... DISABLED
1... ENABLED

Enables/disables the ticket redemption via the bill acceptor.


Tickets will not be accepted.
Tickets will be accepted.

07 2008 AGI GmbH

P a g e
99

GAME & SOFTWARE

MACHINE SETUP > BILL/COIN ACCEPTOR SETUP

Indicates the bill acceptor to which the settings correspond.


Bill channels available.
Monetary value of the bills accepted via the respective bill channel.
Enables/disables the bill channel.
Bills are accepted only if they are inserted in a certain direction.

45M623N5UK-01

BILL ACCEPTOR X
CHANNEL
VALUE
ENABLE
DIRECTION

The bill acceptor and the coin acceptor are disabled when the are close to the CREDIT IN LIMIT.
COIN ACCEPTOR X
CHANNEL
VALUE
ENABLE
P a g e
100

Indicates the coin acceptor to which the settings correspond.


Coin channels available.
Monetary value of the coins accepted via the respective channel.
Enables/disables the coin channel.
07 2008 AGI GmbH

GAME & SOFTWARE

45M623N5UK-01

MACHINE > HOPPER SETUP

HOPPER X
CHANNEL
HOPPER FULL LEVEL


HOPPER LOW LEVEL



HOPPER REFILL LEVEL





ENABLE

07 2008 AGI GmbH

Indicates the hopper to which the settings correspond.


Hopper channels available.
If the adjusted value is reached, another 10 coins are diverted to the
hopper. All coins inserted afterwards are diverted to the drop box by means
of the coin diverter system.
If the adjusted value is reached, the message HOPPER EMPTY is
indicated on the screen after powering down and up the machine. After
turning the attendant key the machine switches to the AUDIT MENU item
Hopper refill (
see part IV.4 - Hopper refill).
The indicated number of coins equals the minimum coin level of the hopper
(depending on market). If the number of the coins inside the hopper is
below this level, the missing number of coins up to this value is indicated in
the menu Hopper refill at MISSING AMOUNT
(
see part IV.4 - Hopper refill). The HOPPER REFILL LEVEL
indicated on this screen is also indicated in the menu Hopper refill.
Enables/disables the hopper.

P a g e
101

GAME & SOFTWARE

MACHINE SETUP > INITIAL SETUP


This menu indicates the current basic settings.

DENOMINATION
CURRENCY
MAIN COIN
TOKENISATION

Indicates the defined accounting value.


Indicates the defined currency.
Indicates the denomination of the main coin (coin acceptor 1/first channel).
Indicates the number of credits per coin (=tokenisation).

MAXIMUM BET
MAXIMUM BET PER ROW
LA WIN LIMIT

GAME WIN LIMIT
ALARM SOUND
MACHINE NUMBER
TYPE OF VALIDATION

Indicates the maximum bet per game.


Indicates the maximum bet per payline.
Indicates the defined LA win limit (LA = Legislation Authority).
The machine will lock if this limit is exceeded.
Indicates the maximum win defined.
Indicates when the alarm sound is activated.
Indicates the configured machine number.
Indicates the defined type of ticket validation.

P a g e
102

07 2008 AGI GmbH

45M623N5UK-01

To change the basic settings first perform a RAM Clear (


see part IV.9 - RAM Clear). Then
press the corresponding buttons or touchscreen areas to select the desired settings.

GAME & SOFTWARE

45M623N5UK-01

If an ethernet network is used, this pages indicate the currently adjusted settings for the network protocol.
NETWORK PROTOCOL
NETWORK ADDRESS
FEATURES

Indicates the network protocol (i.e. IGT, GSP, GRIPS, etc.).


Indicates the network address.
Indicates the status of the individual features (enabled/disabled).
Those features which are not supported by the selected network protocol
are displayed in grey letters.

CONTROL

CASHLESS

BONUSING

TICKET VALIDATION




TICKET REDEMPTION




PROGRESSIVE JACKPOT

MYSTERY JACKPOT

If this feature is enabled, several machine settings can be adjusted via the
network server (i.e. to enable coin channels, bill acceptor).
Enables/disables the cashless card system.
To use a cashless card system, this feature has to be enabled.
Enables/disables a bonusing system via network (additional winning
option).
Enables/disables the ticket printer. To use a ticket printer for payout of
credits, this feature has to be enabled (ON), because this requires a
network protocol. The network protocol depends on the country of
installation. For some countries a second network protocol may be
required.
Enables/disables ticket accepting via bill acceptor. For ticket redemption via
bill acceptor this feature has to be enabled (ON), because this requires a
network protocol. The network protocol depends on the country of
installation. For some countries a second network protocol may be
required.
Enables/disables the jackpot control via the network protocol. The
progressive jackpot is triggered depending on a default win combination.
Enables/disables the jackpot control via the network protocol.
The mystery jackpot is triggered by a random process, independent of bets
or game events.

LINK TYPE
CASHLESS TYPE

Indicates the type of network connection (e.g. Standard, Fibre Optics).


Indicates the type of cashless system (e.g. Standard).

07 2008 AGI GmbH

P a g e
103

GAME & SOFTWARE

Indicates the type of the selected jackpot protocol.


Indicates the jackpot address.
Indicates the name of the progressive jackpot.
Indicates the conversion factor for the jackpot display.
Indicates the configuration of the jackpot levels.

45M623N5UK-01

JACKPOT PROTOCOL
JACKPOT ADDRESS
PROGRESSIVE GAME
SHOW WIN
JACKPOT LEVEL X

P a g e
104

07 2008 AGI GmbH

GAME & SOFTWARE

Indicates the fixed accounting value.


Indicates the number and type of the selected coin acceptor.
Coin channels available.
Definition of the coins accepted via the respective channel.
Indicates the number of credits per coin.

DENOMINATION
BILL ACCEPTOR X
CHANNEL
BILL
TOKENISATION

Indicates the fixed accounting value.


Indicates the number and type of the selected bill acceptor.
Bill channels available.
Definition of the bills accepted via the respective channel.
Indicates the number of credits per bill.

45M623N5UK-01

DENOMINATION
COIN ACCEPTOR X
CHANNEL
COIN
TOKENISATION

07 2008 AGI GmbH

P a g e
105

GAME & SOFTWARE

DENOMINATION
HOPPER X
CHANNEL
COIN
TOKENISATION

Indicates the fixed accounting value.


Indicates the number and type of the selected hopper.
Coin channels available.
Definition of the coins accepted via the respective channel.
Indicates the number of credits per coin.

45M623N5UK-01

MACHINE SETUP> GAMES ENABLE/DISABLE

On this page games can be enabled or disabled.


Games which have been disabled on this page cannot be selected in the game play mode.

P a g e
106

07 2008 AGI GmbH

GAME & SOFTWARE

IV.8.9

CALIBRATION Menu

45M623N5UK-01

CALIBRATION > CLOCK SETUP

yyyy-MMM-dd HH:mm:ss

07 2008 AGI GmbH

Current date and time. Press the respective buttons or touch the
respective fields to perform the settings.

P a g e
107

GAME & SOFTWARE

45M623N5UK-01

CALIBRATION > TOUCH SCREEN CALIBRATION

Follow the instructions indicated on the screen to calibrate the touchscreen.

P a g e
108

07 2008 AGI GmbH

GAME & SOFTWARE

IV.9 RAM Clear


1) Open the Main Door and power down the machine.
2) Open the logic door.
3) Turn the DIP switch 1 to ON (see illustr. IV.9.1).
4) Close the logic door.
5) Power up the machine.
6) After the query has been made press any button to perform a complete RAM Clear.

INFORMATION

Until this moment the RAM Clear may avoided if the machine is powered down before
a button is pressed.

45M623N5UK-01

7) After the RAM Clear is completed, power down the machine.


8) Open the logic door.
9) Turn the DIP switch 1 to OFF (see illustr. IV.9.1).
10) Close the logic door.

11) Power up the machine.


12) Close the Main Door.
13) The machine switches automatically to the AUDIT MENU to system page
MACHINE SETUP > INITIAL SETUP, where the basic settings must be fixed.
14) If a RAM Clear is performed in a cash runner machine with AGI internal jackpot, the machine must
be restarted once prior to determine the jackpot settings (initial value, increment, etc.).
Program ROM

EEPROM

Coolfire Kopie.eps

Illustr. IV.9.1 Position OF DIP switch 1


07 2008 AGI GmbH

P a g e
109

45M623N5UK-01

GAME & SOFTWARE

P a g e
11 0

07 2008 AGI GmbH

45M623N5UK-01

Part V

Hardware

V.1

Power supply

V.2

Bill acceptor

V.3

Coin acceptor

V.4

Hopper

V.5

Monitors and Touchscreen Controller

V.6

COOLFIRE Motherboard

V.7

COOLFIRE Backplane

V.8

Top light

V.9

Illumination

V.10

Mechanical meters

V.11

Door optics/switches

V.12

Loudspeakers

V.13

Preventative maintenance

Austrian Gaming Industries GmbH


07 2008 AGI GmbH Wiener Strasse 158 . A-2352 Gumpoldskirchen . Austria . Europe . Tel.: +43-2252-606 . www.austrian-gaming.com . e-mail: support@novomatic.com

45M623N5UK-01

HARDWARE

There are static-sensitive parts inside the machine which could be damaged by electric
discharge. Ground yourself by touching a ground strap inside the machine to neutralize
electric charges before changing or maintaining inner parts.

P a g e
11 2

Ground straps inside the machine are marked


with yellow stickers as shown beside.
07 2008 AGI GmbH

HARDWARE

Description of components
7

8
1

45M623N5UK-01

10

12

14

16

11
13
15
17

18

19

FV623_Komponenten.eps

Illustr. V.0.1 Description of components

1 Loudspeaker (monitor mask)


2 Coin acceptor
3 Mechanical meters
4 Door in door illumination
5 Door optics (sender)
6 Loudspeaker (main door)
7 Top light
8 Monitors
9 Switching power supply (behind monitors)
10 COOLFIRE Motherboard

07 2008 AGI GmbH

11 Bill acceptor
12 COOLFIRE Backplane
13 Stacker door with lock
14 Hopper
15 Door optics (receiver)
16 Ticket printer (optional)
17 Switching power supply (behind stacker)
18 Main switch
19 Drop door with lock
P a g e
11 3

HARDWARE

Block diagram:
main power supply

option:
coin acceptor

NFS distributor

option:
printer / jackpot controller

COOLFIRE
motherboard

door light barrier


receiver / transmitter

X25

level unit

X21

backplane supply
reel supply

buttons &
lamps

X26

X7/X8/X13/X17
X19
WBA illumination

roulette light box

toplight

X10/X11/X33

VFD display

X3

coin diverter

X6

modular power supply

reel print
coin channel optics

X5

touchscreen

X18

P 384
backplane

X15
X31

X22

doorswitch (BNP)

X24

1. monitor (VGA)
2. monitor (VGA)

X9

meters

X16

loudspeakers
left / right

TFT power supply

LED / lamps controller

X4
hopper

X12/X30/X32
X27

data
supply

power expansion

bill acceptor

X20/X28

network
(online systems)

X23
X2/X14

RS 485 network

IDE

45M623N5UK-01

Blockschaltbild_UK1.eps

Illustr. V.0.2 Block diagram

P a g e
11 4

07 2008 AGI GmbH

HARDWARE

V.1

Power supply

Position in the machine

V.1.2

Function

V.1.3

Troubleshooting

V.1.4

Exchange of the components

45M623N5UK-01

V.1.1

07 2008 AGI GmbH

P a g e
11 5

45M623N5UK-01

HARDWARE

There are static-sensitive parts inside the machine which could be damaged by electric
discharge. Ground yourself by touching a ground strap inside the machine to neutralize
electric charges before changing or maintaining inner parts.

P a g e
11 6

Ground straps inside the machine are marked


with yellow stickers as shown beside.
07 2008 AGI GmbH

HARDWARE

V.1.1

See illustr. V.0.1 on page 113.

V.1.2

Function

Type: NFS - 110 / 7602 P

Power supply for the following components:

24 V / DC for:

Hopper


12 V / DC for:

Hopper
COOLFIRE Backplane

COOLFIRE Backplane

5 V / DC for:

V.1.3

Troubleshooting

Check the connectors of the switching power supply.

V.1.4
45M623N5UK-01

Position in the machine

Exchange of the switching power supply

If any defects cannot be repaired, the defective switching power supply has to be exchanged.

F_623_SchaltnetzteilAusbau.jpg

Illustr. V.1.1 Switching power supply

Dismounting instructions for the switching power supply (see illustr. V.1.1):
1) Open the Main Door and disconnect the machine from the mains.
2) Remove the hopper cover and take out the hopper in forward direction.
3) Disconnect all connectors from the switching power supply.
4) Release the fixing devices.
5) Pull out the switching power supply in left direction and exchange it.
6) Assemble the switching power supply in reverse order.

07 2008 AGI GmbH

P a g e
11 7

45M623N5UK-01

HARDWARE

P a g e
11 8

07 2008 AGI GmbH

HARDWARE

45M623N5UK-01

07 2008 AGI GmbH

V.2

Bill acceptor

V.2.1

Position in the machine

V.2.2

Function

V.2.3

Troubleshooting

V.2.4

Exchange of the bill acceptor

V.2.5

Components of the bill acceptor

V.2.6

Empty stacker

V.2.7

Bills jammed in the bill acceptor

V.2.8

Adjustment of the bill acceptor

P a g e
11 9

45M623N5UK-01

HARDWARE

There are static-sensitive parts inside the machine which could be damaged by electric
discharge. Ground yourself by touching a ground strap inside the machine to neutralize
electric charges before changing or maintaining inner parts.

P a g e
120

Ground straps inside the machine are marked


with yellow stickers as shown beside.
07 2008 AGI GmbH

HARDWARE

V.2.1

See illustr. V.0.1 on page 113.

V.2.2

Troubleshooting

Check the bill acceptor whether it is fixed correctly in its mounting.


Check the connectors of the bill acceptor and the COOLFIRE Backplane.

V.2.4

Exchange of the bill acceptor

If any defects cannot be repaired, the defective bill acceptor has to be exchanged.

45M623N5UK-01

Function

Type: WBA-25-SS2, Cashflow SC83 or compatible.


The bill acceptor is programmed for the respective national currency.

V.2.3

Position in the machine

WBA25_624.eps

Illustr. V.2.1 Lock bar of the bill acceptor WBA-25-SS2

SC83_imGeraet.eps

Illustr. V.2.2 Bill acceptor Cashflow SC83

V.2.4.1 Dismounting instructions for the bill acceptor WBA-25-SS2:


1) Open the Main Door and disconnect the machine from the mains.
2) Press down the lock bar of the bill acceptor and simultaneously take out the bill acceptor in forward
direction (see illustr. V.2.1).
3) To remove the mouthpiece release both fixing screws and press the two bars located on the upper side
in forward direction. Then exchange the bill acceptor.
4) Assemble the bill acceptor in reverse order.

07 2008 AGI GmbH

P a g e
121

HARDWARE

V.2.4.2 Dismounting instructions for the bill acceptor Cashflow SC83:


1) Open the Main Door and disconnect the machine from the mains.
2) Press upwards on the release lever located on the front of the acceptor module and pull out
the bill acceptor (see illustr. V.2.3).

F_CashFlow_Ausbau.eps

Illustr. V.2.3

SC83_Einbau.eps

Exchange of the bill acceptor Cashflow SC83

3) Exchange the bill acceptor.


4) Pull back the bill acceptor into its retainer until the lock bar engages (see illustr. V.2.3).
5) Switch on the machine and close the Main Door.

Components of the bill acceptor

Transfer unit
cover

Latches

Bill slot

Locking bar of the


bill acceptor

Locking bar of the


stacker box

Stacker box
SC83_Komponenten.eps

Illustr. V.2.4 Components Cashflow SC83

P a g e
122

45M623N5UK-01

V.2.5

WBA 3D.eps

Illustr. V.2.5 Components WBA-25-SS2

07 2008 AGI GmbH

HARDWARE

V.2.6

Empty stacker

V.2.6.1 Collecting bills at bill acceptor WBA-25-SS2:

Stackertausch 3D.eps

Illustr. V.2.6 Collecting bills - WBA-25-SS2

1) Open the stacker door.


2) Press down the locking bar of the stacker and keep it pressed.
Take out the stacker in forward direction.

3) Open the stacker and collect the bills.


4) By re-inserting the stacker the locking bar engages automatically.

45M623N5UK-01

V.2.6.2 Collecting bills at bill acceptor Cashflow SC83:

SC83_Stacker1.eps / SC83_Stacker2.eps

Illustr. V.2.7 Collecting bills - Cashflow SC83

1) Open the stacker door.


2) Grab the yellow strap on the stacker box and pull it firmly to release it.
3) Open the stacker and collect the bills.
4) Re-insert the stacker

ATTENTION

Great amounts of money may be inside the stacker box!


Remove the stacker only in a safe surrounding!

07 2008 AGI GmbH

P a g e
123

HARDWARE

V.2.7

Removing jammed bills in the bill acceptor

V.2.7.1 Bill acceptor WBA-25-SS2

in the sensors

in the bill transporter

behind stacker box

Illustr. V.2.8 Removing jammed bills - WBA-25-SS2

Depending on the situation encountered jammed bills must be removed as shown in illustr. V.3.8.

45M623N5UK-01

V.2.7.2 Bill acceptor Cashflow SC83

ATTENTION

You must remove the acceptor module from the chassis to open the front sensor area!

Illustr. V.2.9 Removing jammed bills - Cashflow SC83

1) Remove the acceptor module.


2) Open the acceptor module and remove the jammed bills.
3) Re-insert the acceptor module.

P a g e
124

ATTENTION

Great amounts of money may be inside the stacker box!


Remove the stacker box only in a safe surrounding!

07 2008 AGI GmbH

HARDWARE

V.2.8

Adjustment of the bill acceptor


These instructions are only valid for the bill acceptor WBA-25-SS2, because the bill acceptor
Cashflow SC83 was designed no to require calibration.

The adjustment of the sensors is intended to compensate any slight age-related cloudiness of the
optical lenses (black and white adjustment) or any normal wear of the optical sensors.
Therefore, the adjustment procedure described below should be carried out when required.
Note: The adjustment is not a substitute for cleaning the sensor lenses!
The sensor lenses should also be cleaned before each sensor adjustment.
The below instructions should be followed strictly!

Description:
1) Release the connecting plugs from the WBA (e.g. by pulling out the acceptor unit).
2) Set DIP switches

45M623N5UK-01

8, 7, 6 and 5 to ON
1, 2, 3 and 4 to OFF

3) Connect the WBA to the power supply (by inserting the acceptor unit in the acceptor frame).

WBA.eps

Illustr. V.2.10 Acceptor unit of the bill acceptor

4) The emergency transport motor will first run forward approx. 2 seconds and then briefly reverse.
5) Now the reference paper KS-039 (EDP item no. 075626) can be inserted with the black end in first.
The WBA pulls the paper in automatically and moves it forward and backwards several times.
6) The auto-adjustment is completed once the reference paper has been ejected and the transport
motor has come to a halt. After that, the acceptor requires approx. another 2 - 3 seconds to write
the data to the internal memory chip.
7) Disconnect the acceptor unit from the power supply again and return the DIP switches to their
original status, which will normally be all switches in OFF position.

8) Connect the WBA to the power supply.


07 2008 AGI GmbH

P a g e
125

45M623N5UK-01

HARDWARE

P a g e
126

07 2008 AGI GmbH

HARDWARE

45M623N5UK-01

07 2008 AGI GmbH

V.3

Coin acceptor

V.3.1

Position in the machine

V.3.2

Function

V.3.3

Troubleshooting

V.3.4

Exchange of the coin acceptor

V.3.5

Programming

V.3.6

Block switch-over NRI

V.3.7

Teach Mode

P a g e
127

45M623N5UK-01

HARDWARE

There are static-sensitive parts inside the machine which could be damaged by electric
discharge. Ground yourself by touching a ground strap inside the machine to neutralize
electric charges before changing or maintaining inner parts.

P a g e
128

Ground straps inside the machine are marked


with yellow stickers as shown beside.
07 2008 AGI GmbH

HARDWARE

V.3.1

Position in the machine


See illustr. V.0.1 on page 113.

V.3.2

Function

Type: NRI-G13 coin acceptor, MC-40 coin comparitor or compatible.

The coin diverter below the coin acceptor sorts the coins into either the hopper or drop box.

V.3.3

Troubleshooting

If any defects of the coin acceptor cannot be repaired, the defective component has to be exchanged.
1) Open the Main Door and disconnect the machine from the mains.
2) Check if the coin acceptor is fixed correctly in its mounting.

45M623N5UK-01

3) Check the connections of the coin acceptor.


4) Check if the coin diverter can be freely moved between its two positions (if a coin diverter is installed).

07 2008 AGI GmbH

P a g e
129

HARDWARE

V.3.4

Exchange of the coin acceptor

If any defects of the coin acceptor cannot be repaired, the complete component has to be exchanged.

F_MnzprferAusbau.eps

Illustr. V.3.1 Exchange of the coin acceptor NRI-G13

Mnzkanallichtschranke.eps

Dismounting instructions for the coin acceptor NRI-G13 (see illustr. V.3.1):
1) Open the Main Door and disconnect the machine from the mains.
2) Take out the coin acceptor by grabbing it on the upper edge and pull it out from the brackets.
3) Disconnect the plug connectors between machine and coin comparitor.
4) Assemble the coin acceptor in reverse order.

Dismounting instructions for the coin comparitor MC-40 (see illustr. V.3.2):
1) Open the Main Door and disconnect the machine from the mains.
2) Press down the levers of the coin comparitor lock and take out the coin comparitor from its mounting.
Release the connectors.
3) Unscrew the coin optics board and release the connectors (only if the board is defective).
4) Exchange the coin comparitor (or the optics board).
5) Assemble the coin comparitor and the coin optics board in reverse order.

P a g e
130

07 2008 AGI GmbH

45M623N5UK-01

Illustr. V.3.2 Exchange of the coin comparitor MC-40

HARDWARE

V.3.5


Programming (NRI-G13)

The coin acceptor NRI-G13 is already programmed for the currency of the country of installation.
Programmed currencies and coins are described on the coin acceptor label. Programming of new
coins or currencies is carried out through the DIP switches on the backside of the coin acceptor.

Neu Plakette Mnzprfer.eps

Neu Dip-Schalter Mnzprfer.eps

45M623N5UK-01

Illustr. V.3.3 Programming of the coin acceptor NRI-G13

07 2008 AGI GmbH

P a g e
131

HARDWARE

V.3.6

Block switch-over NRI

Starting with model no. G-13/1 the validator offers the possibility to have two configurations, independent
from each other. To each of these blocks 12 individual coin channels are assigned with appropriate
tables (signals, denominations, sorting information). The programming is done either at NRI or at a
service station.
Although both blocks are programmed you can only work with one of them.
This type of validator can be recognized by the label with the extended indications.

This function is ideal for storing additionally to the actual currency a second coin combination with
individual interface information (table). For example in case of a currency conversion the actual
settings are deactivated and the new ones are activated. A further application can be if independent
from currency and alternative vending machine interface is selected.

For standard devices the switch-over is done by only one DIL-switch!

On the rear of the NRI G-13 two switch arrangements are positioned. For switching over from
block 0 to block 1 please use switch no. 8 of the right-hand switch arrangement. Please proceed
as follows:

P a g e
132

45M623N5UK-01

1) Switch off power supply.


2) Switch on switch no. 8 of the right-hand switch arrangement
- lower position = block 0 active only (left side on label)
- upper position = block 1 active only (right side on label)
3) Switch on power supply.
4) Check coin acceptance (please refer to label).

07 2008 AGI GmbH

HARDWARE

V.3.7

Teach Mode

By using the teach mode you can programme coins or token in channel 10 and 11. In all versions
of the G-13 validator the teach mode is programmable. However, a combination of the 2-price-totalizer
with sales counter and the teach mode does not make sense as the tasks of the switch for single coins
inhibit for the 12th channel would overlap each other.

Using the teach mode

The validator remains connected in the vending machine.

45M623N5UK-01

1) On the rear of the validator two Dual-In-Line switches are positioned. Switch no. 12 ON.
2) Depending on the intention to teach channel 10 or 11, please switch ON the appropriate switch.
3) Insert coins or token.
After insertion of the 10th coin (token) the validator gives an acoustic signal (click of the
acceptance gate). The measured values are now registered.
4) Turn switch no. 12 OFF.
5) Also turn appropriate switch for channel 10 or 11 OFF.
Once again the acceptance gate gives an acoustic signal (1 time), i.e. the programming has
been finished successfully.

Channel

10

11

12

13

ON

14

OFF
MP DIL_englisch.eps

Illustr. V.3.4 DIL switch on coin acceptor

In case the acceptance rate for a coin or token programmed by teach mode is not sufficient, you can
programme the coin or token with wider acceptance bandwidths. Therefore please
do the following:
1) DIL switch no. 12 ON. Teach mode is now active.
2) Turn switch for desired channel 10 or 11 ON.
3) Insert new coin or token at least 10 times.
The acceptance gate gives an acoustic signal (1 time). Coin values are registered.
4) Turn channel no. 10 and 11 ON.
Wide acceptance bandwidths are now calculated.
5) Turn switch no. 12 OFF.
6) Turn switch 10 and 11 OFF.
Coin or token is now programmed. The teach mode has now been finished and
the channel 10 and 11 are enabled.

07 2008 AGI GmbH

P a g e
133

HARDWARE

In case the acceptance gate gives an acoustic signal twice,


the following reasons could be possible:
1) Coin could not be programmed. It exists to overlapping of the acceptance limits
with already programmed coins / tokens.
2) An error has happened during measurements.
3) The programming has been interrupted.
4) The acceptance limits could not be assigned to a channel as switch no. 10 or 11
was turned ON first instead of switch no. 12.
If a coin or token could not be programmed the existing values remain stored in any case.

45M623N5UK-01

P a g e
134

07 2008 AGI GmbH

HARDWARE

45M623N5UK-01

07 2008 AGI GmbH

V.4

Hopper

V.4.1

Position in the machine

V.4.2

Function

V.4.3

Troubleshooting

V.4.4

Exchange of the hopper

V.4.5

Hopper high-level

P a g e
135

45M623N5UK-01

HARDWARE

There are static-sensitive parts inside the machine which could be damaged by electric
discharge. Ground yourself by touching a ground strap inside the machine to neutralize
electric charges before changing or maintaining inner parts.

P a g e
136

Ground straps inside the machine are marked


with yellow stickers as shown beside.
07 2008 AGI GmbH

HARDWARE

V.4.1

Position in the machine


See illustr. V.0.1 on page 113.

V.4.2

Function

Type: Universal hopper MK IV or compatible.

Storage of coins inserted by means of a diverter control system and payout of the wins.

V.4.3


Troubleshooting

Check if the hopper and the connectors are fixed correctly in their mounting.
Check if the hopper is pushed all the way in and if it is connected to the multi interface.
In addition, check if a coin is stuck and if the hopper needs cleaning.

Exchange of the hopper

45M623N5UK-01

V.4.4

F_Hopper.jpg

Illustr. V.4.1 Exchange of the hopper

07 2008 AGI GmbH

P a g e
137

HARDWARE

Dismounting instructions for the hopper (see illustr. V.4.1):


1) Open the Main Door and disconnect the machine from the mains.
2) Remove the hopper cover.
3) Take out the hopper in direction of the arrow.
4) Exchange the hopper.
5) Assemble the hopper in reverse order.

V.4.5

Hopper high-level

45M623N5UK-01

Two contact plates are located at the top inside the hopper. When the high level of the hopper is reached,
i.e. the two contact plates are reached, another 10 coins are diverted to the hopper. All coins inserted
afterwards are diverted to the drop box by means of the coin diverter system
(
see part IV.8 - AUDIT MENU > MACHINE > HOPPER SETUP).

P a g e
138

07 2008 AGI GmbH

HARDWARE

45M623N5UK-01

07 2008 AGI GmbH

V.5

Monitors

V.5.1

Position in the machine

V.5.2

Function

V.5.3

Troubleshooting

V.5.4

Exchange of the monitors

V.5.5

Adjustment of the screen

P a g e
139

45M623N5UK-01

HARDWARE

There are static-sensitive parts inside the machine which could be damaged by electric
discharge. Ground yourself by touching a ground strap inside the machine to neutralize
electric charges before changing or maintaining inner parts.

P a g e
140

Ground straps inside the machine are marked


with yellow stickers as shown beside.
07 2008 AGI GmbH

HARDWARE

V.5.1

See illustr. V.0.1 on page 113.

V.5.2

Troubleshooting

Check if the monitors and the connectors of the cables are fixed correctly in their mounting.

V.5.4

Exchange of the monitors

If any defects cannot be repaired, the defective monitor has to be exchanged.

45M623N5UK-01

Function

The monitors show the game play, the error messages and the audit system.

V.5.3

Position in the machine

F_623-V05_unten1.eps

623-V05_unten2.eps

Illustr. V.5.1 Exchange of the lower monitor (FV-623)

Dismounting instructions for the lower monitor:


1) Open the Main Door and disconnect the machine from the mains.
2) Open the lower monitor retainer inside the machine by lifting and turning it forward (see illustr. V.5.1).
3) Disconnect the plug and cable connectors of the monitor which has to be exchanged.
Do not touch circuit board! High voltage!
4) Grab the monitor with both hands and take it out of its retainer.
5) Exchange the defective monitor.
6) Assemble the monitor in reverse order.

07 2008 AGI GmbH

P a g e
141

HARDWARE

F_623-V05_oben1.eps

F_623-V05_oben2.eps

Illustr. V.5.2 Exchange of the upper monitor (FV-623)

1) Open the Main Door and disconnect the machine from the mains.
2) Open the upper monitor retainer inside the machine by lifting and turning it forward (see illustr. V.5.2).
3) Disconnect the plug and cable connectors of the monitor which has to be exchanged.
Do not touch circuit board! High voltage!
4) Disconnect the security chain on the left side.
5) Grab the monitor with both hands and take it out of its retainer.
6) Exchange the defective monitor.
7) Assemble the monitor in reverse order.

P a g e
142

07 2008 AGI GmbH

45M623N5UK-01

Dismounting instructions for the upper monitor:

HARDWARE

V.5.5

Adjustment of the screen

At the rear of the monitor, a print is attached for the adjustment of brightness, contrast and
geometry of the picture.

A
B
C
D
E
F_Einstellung_Monitor.eps

45M623N5UK-01

Illustr. V.5.3 Buttons for adjustment of the screen

Adjustment
The monitors can be adjusted via the buttons on the rear side of the respective monitor.



A Minimises the selected adjustment.


B Increases the selected adjustment.
C ON/OFF switch.
D Auto-adjustment. By pressing this button, an automatic adjustment sequence is started
by the monitors software.
E Adjustment menu: By pressing this button, the menu adjustment is shown on the screen.
Navigate to the functions which have to be set and adjust them. To leave the adjustment
menu, press EXIT.

07 2008 AGI GmbH

P a g e
143

45M623N5UK-01

HARDWARE

P a g e
144

07 2008 AGI GmbH

HARDWARE

45M623N5UK-01

07 2008 AGI GmbH

V.6

COOLFIRE Motherboard

V.6.1

Position in the machine

V.6.2

Function

V.6.3

Troubleshooting

V.6.4

Exchange of the mainboard

V.6.5

DIP switch

V.6.6

Exchange of other components

P a g e
145

45M623N5UK-01

HARDWARE

There are static-sensitive parts inside the machine which could be damaged by electric
discharge. Ground yourself by touching a ground strap inside the machine to neutralize
electric charges before changing or maintaining inner parts.

P a g e
146

Ground straps inside the machine are marked


with yellow stickers as shown beside.
07 2008 AGI GmbH

HARDWARE

V.6.1

See illustr. V.0.1 on page 113.

V.6.2




ATTENTION

When pushing in the COOLFIRE motherboard make sure that the connectors lock in correctly to the
COOLFIRE backplane.

V.6.3

45M623N5UK-01

Function

Game control and drive of the components.


The COOLFIRE motherboard is the mainboard of the machine. The security switch lock is located on the
front side of the COOLFIRE motherboard, between the two grips, and is responsible for the storing of the
accounting data. It is strictly prohibited to use a bridge connector for this switch (this might result in
data loss!).

Position in the machine

Troubleshooting

If any defects of the COOLFIRE motherboard (mainboard) cannot be repaired, the board has to be
exchanged.

V.6.4

Exchange of the COOLFIRE Motherboard

F_623CF_Tausch.eps

Illustr. V.6.1 Exchange of the mainboard

Dismounting instructions for the mainboard. (see illustr. V.6.1):


1) Open the Main Door and disconnect the machine from the mains.
2) Open the security switch lock.
3) Take both grips of the COOLFIRE motherboard and pull strongly to take it out.
4) Assemble the mainboard in reverse order.

07 2008 AGI GmbH

P a g e
147

HARDWARE

V.6.5

The DIP switch is used to perform a RAM Clear.


How to perform a RAM Clear see part IV.9.

Coolfire Kopie.eps

Illustr. V.6.2 DIP switch position

P a g e
148

07 2008 AGI GmbH

45M623N5UK-01

DIP switch

HARDWARE

V.6.6

Exchange of other components

F_MotherboardBest.eps

Illustr. V.6.3 Position game selector (1), game software (2), EEPROM (3)

45M623N5UK-01

V.6.6.1 Exchange of the game selector (1)


1) Take out the mainboard.
2) Remove the existing game selector from the motherboard by pulling it straight up.
3) Plug in the new game selector.
4) Install the mainboard back in again.

07 2008 AGI GmbH

P a g e
149

HARDWARE

V.6.6.2 Exchange of the game software (2)


1) Take out the mainboard.
2) Press both holding clips on the left and the right sideways (see illustr. V.6.4).
3) Tilt the software module towards the rear side of the motherboard and pull it out.
4) Insert the new software module in the plug-in socket at a slight angle (the software
module can be inserted only in one position!).
5) Tilt the software module to the front side of the motherboard until the two
holding clips click into their place.
6) Assemble the mainboard.
2

F_MotherboardBest.eps

Illustr. V.6.4 Exchange of the game software

V.6.6.3 Exchange of the EEPROM (3)

45M623N5UK-01

1) Take out the mainboard.


2) Remove the existing EEPROM by pulling it straight up.
3) Insert the new EEPROM (see illustr. V.6.5).

ATTENTION

Note the insertion direction!


4) EEPROM and the socket have a notch on one side.
When installing the EEPROM ensure that the notch on the EEPROM and the notch
on the socket both show in the same direction!
5) Install the mainboard back in again.

EEPROM+Sockel.eps

Illustr. V.6.5 Correct insertion position of the EEPROM

!
P a g e
150

ATTENTION

After the components have been exchanged, a RAM Clear may be necessary!
07 2008 AGI GmbH

HARDWARE

45M623N5UK-01

07 2008 AGI GmbH

V.7

COOLFIRE Backplane

V.7.1

Position in the machine

V.7.2

Function

V.7.3

Position of the connectors

V.7.4

Pin assignment

V.7.5

Troubleshooting

V.7.6

Exchange of the COOLFIRE Backplane

P a g e
151

45M623N5UK-01

HARDWARE

There are static-sensitive parts inside the machine which could be damaged by electric
discharge. Ground yourself by touching a ground strap inside the machine to neutralize
electric charges before changing or maintaining inner parts.

P a g e
152

Ground straps inside the machine are marked


with yellow stickers as shown beside.
07 2008 AGI GmbH

HARDWARE

V.7.1

Position in the machine

See illustr. V.0.1 on page 113.

V.7.2

Function

The COOLFIRE backplane is responsible for all input and output signals of the main electronic unit.

V.7.3

Position of the connectors

X16

X21

LED colour

function

red

+5 V

yellow

+12 V

green

+24 V

yellow

-12 V

X31

J2

J3 J7

J6

J1

LED colour

function

rot

release WBA

X25

X26

X23

X1

45M623N5UK-01

X22
1

X4
X27
X24

X10

X11

X33

X30

X12

X32

X9

Illustr. V.7.1 Pin assignment COOLFIRE backplane

X1 - Jumper for RS 232 level


X2 - EBA bill acceptor
X3 - VFD display
X4 - Network
X5 - Coin channel optics
X6 - Coin diverter
X7 - NRI coin acceptor
X8 - CC coin acceptor
X9 - Mechanical meters
X10, X11, X33 - Switching power supply
X12 - Hopper 2
X13 - 2. NRI coin acceptor (only 1 channel)
X14 - WBA bill acceptor
X15 - WBA illumination
X16 - Loudspeakers
07 2008 AGI GmbH

X2 X17

X13
X7

X8

X6
X5

X15
X14

X3

X18
X19

J4
X28

F_CF_384_3.jpg

X20

X17 - Cash Flow coin acceptor


X18 - Touchscreen
X19 - Jackpot controller
X20, X28 - RS 485 network
X21 - COOLFIRE motherboard X13
X22 - VGA 1
X23 - IDE
X24 - VGA 2
X25 - COOLFIRE motherboard X12
X26 - COOLFIRE motherboard X11
X27 - Power expansion
X30 - Hopper 1
X31 - Main wire loom (64 pins)
X32 - Hopper 3
Jn - Jumper
P a g e
153

HARDWARE

V.7.4

Pin assignment

J1 - Pin 1/2 pulldown resistor for ENABLE (coin acceptor)


Pin 2/3 pullup resistor for ENABLE (coin acceptor)
J2 - INH (bill acceptor)
J3 - ACK (bill acceptor)
J4 - RS 485 Jumper for timing
J6 - Monitoring (bill acceptor)
J7 - REJ (bill acceptor)

P a g e
154

PIN
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

FUNCTION
+5V DC
+5V DC
GND

GND
GND
GND
+12V DC
+12V DC
-12V DC
-12V DC
NTXD IN1
NTXD OUT
NTXD IN2
NTXD OUT
NRTS IN1
NRTS OUT
NRTS IN2
NRTS OUT
NRXD OUT
NRXD IN
Receiver OUTPUT_D
Receiver INPUT_D
NCTS OUT
NCTS IN
Receiver OUTPUT_C
Receiver INPUT_C

X1 - Jumper for RS 232 level


TTL
+ 5V DC

RS 232
+/- 12V DC

TX

pin 11/12

pin 13/14

RX

pin 19/20

pin 19/21
pin 20/22

RTS

pin 15/16

pin 17/18

CTS

pin 23/24

pin 23/25
pin 24/26

07 2008 AGI GmbH

45M623N5UK-01


Connector X1
Jumper for RS 232 Level (26 pin male connector)

HARDWARE

45M623N5UK-01

Connector X2
EBA bill acceptor (26 pin male connector)


























PIN
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

FUNCTION
+12V DC
BAGND
+12V DC
BAGND
VEND1
GND
VEND2
GND
VEND3
GND
BUSY
GND
ABN
GND
+5V DC
INH
+5V DC
nACK
+5V DC
nREJ
DATA VALID
GND
STK FULL
GND
N.C.
N.C.

Connector X3
VFD display (10 pin Lock Header)










PIN
01
02
03
04
05
06
07
08
09
10

07 2008 AGI GmbH

FUNCTION
+5V DC
GND
D-TX
D-DTR
D-RTS
N.C.
D-RX
N.C.
N.C.
D-RI

Connector X4
Network (8 pin Mini Fit Header)








PIN
01
02
03
04
05
06
07
08

FUNCTION
+5V DC
GND
+12V DC
-12V DC
NTXD
NRTS
NRXD
NCTS

Connector X5
Coin channel optics (5 pin Lock Header)





PIN
01
02
03
04
05

FUNCTION
+12V DC
GND
C_CH_A
C_CH_B
C_CH_C

Connector X6
Coin diverter (3 pin Lock Header)



PIN
01
02
03

FUNCTION
nCCHS1
nCCHS2
+12V DDC

Connector X7
NRI coin acceptor (10 pin male connector)










PIN
01
02
03
04
05
06
07
08
09
10

FUNCTION
NRI-GND
+12V DC
KAN5
KAN6
REJECT
nNRI-ENABLE
KAN1
KAN2
KAN3
KAN4
P a g e
155

HARDWARE

PIN
01
02
03
04
05
06
07
08

FUNCTION
TILT
N.C.
nCC-CREDIT
CC-GND
+12V DC
nCC-ENABLE
nCC-SENSE
GND

Connector X9
Mechanical meters (15 pin D-Sub female connector)















PIN
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15

FUNCTION
nMETER1

nMETER2
nMETER3
METER4
METER5
METER6
LAMPSON
METERCOUNT
L_AREA1
GND
GND
nMETER7
nMETER8
+12V DC
+12V DC

Connector X10, X11, X33


Switching power supply (12 pin Mini Fit Header)













P a g e
156

PIN
01
02
03
04
05
06
07
08
09
10
11
12

FUNCTION
+5V-PS
GND
+12V-L
PGND
+24V DC
BAGND
+5V-PS
GND
+12V-PS
PGND
nPFI
-12V DC

Connector X12
Hopper 2 (14 pin Mini Fit Header)














PIN
01
02
03
04
05
06
07
08
09
10
11
12
13
14

FUNCTION
H2_M+
H2_M+12V DC
GND
HIGH LEVEL
LOW LEVEL
COIN OUT
SECURITY
H2_INP1
H2_INP2
H2_INP3
+24V DC
PGND
+5V DC

Connector X13
NRI coin acceptor (only 1 channel)
(10 pin male connector)










PIN
01
02
03
04
05
06
07
08
09
10

45M623N5UK-01

Connector X8
CC coin acceptor (8 pin Lock Header)

FUNCTION
CC-GND

+12V DC
N.C.
N.C.
N.C.
nCC-ENABLE
N.C.
nCC-CREDIT
N.C.
N.C.

Connector X14
WBA bill acceptor (10 pin Mini Fit Header)










PIN
01
02
03
04
05
06
07
08
09
10

FUNCTION
+12V DC
nBA-RESET
+12V DC
GND
LED+
BAGND
BA-TXD
BA-RXD
LEDN.C.
07 2008 AGI GmbH

HARDWARE

Connector X15
WBA illumination (4 pin Lock Header)




PIN
01
02
03
04

FUNCTION

Connector X16
Loudspeakers (4 pin Mini Fit Header)




PIN
01
02
03
04

FUNCTION

45M623N5UK-01

PIN
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16

07 2008 AGI GmbH

PIN
01
02
03
04
05
06
07
08
09

FUNCTION
B-DCD
B-RX
B-TX
B-DTR
GND
B-DSR
B-RTS
B-CTS
B-RI

Connector X19
Jackpot controller (15 pin D-Sub male connector)

Connector X17
Cash Flow coin acceptor (16 pin male connector)

Connector X18
Touchscreen (9 pin D-Sub male connector)

FUNCTION

PIN
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15

FUNCTION
C-DCD
C-RX
C-TX
C-DTR
GND
GND
GND
GND
C-DSR
C-RTS
C-CTS
C-RI
N.C.
N.C.
N.C.

Connector X20, X28


RS 485 network (4 pin modular jack)




PIN
01
02
03
04

FUNCTION
N.C.
Signal A
Signal B
N.C.

P a g e
157

HARDWARE

P a g e
158

PIN
A01
A02
A03
A04
A05
A06
A07
A08
A09
A10
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
A21
A22
A23
A24
A25
A26
A27
A28
A29
A30
A31
A32

FUNCTION
GND
AOUT1GND
+5V-MB
IN2
GMD
IN12
IN6
GND
+5V-MB
OUT2
OUT9
GND
OUT6
OUT13
GND
+5V-MB
IN26
IN20
GND
IN30
IN24
GND
+5V-MB
OUT26
OUT21
GND
OUT30
IN33
IN42
GND
+5V-MB

PIN
B01
B02
B03
B04
B05
B06
B07
B08
B09
B10
B11
B12
B13
B14
B15
B16
B17
B18
B19
B20
B21
B22
B23
B24
B25
B26
B27
B28
B29
B30
B31
B32

FUNCTION
L_AREA1
+12V-MB
AOUT2+
IN1
IN10
IN11
IN5
IN14
IN15
IN16
OUT3
OUT10
OUT12
OUT7
OUT14
OUT16
IN25
IN19
IN28
IN29
IN23
IN32
OUT18
OUT20
OUT27
OUT22
OUT24
OUT31
IN41
IN35
IN36
IN37

PIN
C01
C02
C03
C04
C05
C06
C07
C08
C09
C10
C11
C12
C13
C14
C15
C16
C17
C18
C19
C20
C21
C22
C23
C24
C25
C26
C27
C28
C29
C30
C31
C32

FUNCTION
AOUT1+
+12V-MB
AOUT2IN9
IN3
IN4
IN13
IN7
IN8
OUT1
OUT4
OUT11
OUT5
OUT8
OUT15
IN17
IN18
IN27
IN21
IN22
IN31
OUT17
OUT19
OUT25
OUT28
OUT23
OUT29
OUT32
IN34
IN43
IN44
IN45

07 2008 AGI GmbH

45M623N5UK-01

Connector X21
COOLFIRE motherboard (96 pin female connector)

45M623N5UK-01

HARDWARE

Connector X22
VGA 1 (15 pin D-Sub female connector)

Connector X23
IDE (40 pin male connector)

PIN
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15

FUNCTION
R_OUT1
G_OUT1
B_OUT1
GND
GND
GND
GND
GND
N.C.
GND
GND
N.C.
HSYNC_OUT1
VSYNC_OUT1
N.C.

Connector X24
VGA 2 (15 pin D-Sub female connector)















PIN
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15

07 2008 AGI GmbH

FUNCTION
R_OUT2
G_OUT2
B_OUT2
GND
GND
GND
GND
GND
N.C.
GND
GND
N.C.
HSYNC_OUT2
VSYNC_OUT2
N.C.

PIN
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

FUNCTION
nD1RESET
GND
D1D7
D1D8
D1D6
D1D9
D1D5
D1D10
D1D4
D1D11
D1D3
D1D12
D1D2
D1D13
D1D1
D1D14
D1D0
D1D15
GND
N.C.
N.C.
GND
nD1IOWR
GND
nD1IORD
GND
D1IORDY
N.C.
N.C.
GND
D1INTRQ
nIOCS16
D1A3
N.C.
D1A2
D1A4
D1E_CS0
D1E_CS1
N.C.
GND

P a g e
159

HARDWARE

P a g e
160

PIN
A01
A02
A03
A04
A05
A06
A07
A08
A09
A10
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
A21
A22
A23
A24
A25
A26
A27
A28
A29
A30
A31
A32

FUNCTION
GND
GND
+5V-MB
OUT33
OUT36
GND
OUT37
OUT40
GND
+5V-MB
IN50
IN59
GND
IN54
IN63
GND
+5V-MB
OUT57
OUT60
GND
nPFI
nERID
GND
+5V-MB
nETXC
nECTSC
GND
nERXB
nEDSRB
nERTSB
GND
+5V-MB

PIN
B01
B02
B03
B04
B05
B06
B07
B08
B09
B10
B11
B12
B13
B14
B15
B16
B17
B18
B19
B20
B21
B22
B23
B24
B25
B26
B27
B28
B29
B30
B31
B32

FUNCTION
IN38
IN39
IN40
OUT34
OUT41
OUT43
OUT38
OUT45
OUT47
IN49
IN58
IN52
IN53
IN62
IN56
OUT49
OUT51
OUT58
OUT53
OUT55
INT_RES
nEDCDD
nECTSD
nERTSD
nERTSC
nEDSRC
nERIC
nERIB
nECTSB
nETXB
nERTSA
nECTSA

PIN
C01
C02
C03
C04
C05
C06
C07
C08
C09
C10
C11
C12
C13
C14
C15
C16
C17
C18
C19
C20
C21
C22
C23
C24
C25
C26
C27
C28
C29
C30
C31
C32

FUNCTION
IN46
IN47
IN48
OUT35
OUT42
OUT44
OUT39
OUT46
OUT48
IN57
IN51
IN60
IN61
IN55
IN64
OUT50
OUT52
OUT59
OUT54
OUT56
nERXD
nEDSRD
nEDTRD
nETXD
nEDTRC
nEDCDC
nERXC
nEDCDB
nEDTRB
nETXA
nEDTRA
nEDSRA

07 2008 AGI GmbH

45M623N5UK-01

Connector X25
COOLFIRE motherboard (96 pin female connector)

HARDWARE

45M623N5UK-01

Connector X26
COOLFIRE motherboard (96 pin female connector)
































PIN
A01
A02
A03
A04
A05
A06
A07
A08
A09
A10
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
A21
A22
A23
A24
A25
A26
A27
A28
A29
A30
A31
A32

07 2008 AGI GmbH

FUNCTION
nEDCDA
GND
D1A3
GND
+5V-MB
GND
D1D0
GND
+5V-MB
GND
D1D10
D1D6
GND
+5V-MB
GND
ED5
+5V-MB
GND
EA6
GND
nI/O_RESET
GND
nECTS2
+5V-MB
RES_CTRL4
GND
GND
GND
GND
GND
GND
GND

PIN
B01
B02
B03
B04
B05
B06
B07
B08
B09
B10
B11
B12
B13
B14
B15
B16
B17
B18
B19
B20
B21
B22
B23
B24
B25
B26
B27
B28
B29
B30
B31
B32

FUNCTION
nERIA
D1E_CS1
D1A2
nIOCS16
nD1IORDY
nD1IOWR
D1D14
D1D13
D1D12
D1D11
D1D5
D1D8
nD1RESET
ED1
ED3
ED6
EA2
EA4
EA7
nIORD
nECTS1
ERXD1
ERXD2
nCS_RES1
RES_CRTL5
RES_OUT2
R_OUT2
G_OUT2
B_OUT2
R_OUT1
G_OUT1
B_OUT1

PIN
C01
C02
C03
C04
C05
C06
C07
C08
C09
C10
C11
C12
C13
C14
C15
C16
C17
C18
C19
C20
C21
C22
C23
C24
C25
C26
C27
C28
C29
C30
C31
C32

FUNCTION
nERXA
D1E_CSO
D1A4
D1INTR
nD1IORD
D1D15
D1D1
D1D2
D1D3
D1D4
D1D9
D1D7
ED0
ED2
ED4
ED7
EA3
EA5
EA8
nIOWR
nERTS1
ETXD1
ETXD2
RES_CTRL3
RES_CTRL6
RES_IN1
nCS_RES0
VSYNC_OUT2
HSYNC_OUT2
VSYNC_OUT1
HSYNC_OUT1
GND

P a g e
161

HARDWARE

Connector X27
Power expansion (6 pin Mini Fit Header)

Connector X32
Hopper 3 (16 pin Mini Fit Header)

FUNCTION
+12V DC
GND
+5V DC
+12V DC
GND
+5V DC

Connector X30
Hopper 1 (14 pin Mini Fit Header)














P a g e
162

PIN
01
02
03
04
05
06
07
08
09
10
11
12
13
14

FUNCTION
H1_M+
H1_M+12V DC
GND
HIGH LEVEL
LOW LEVEL
COIN OUT
N.C.
SECURITY
H1_INP1
H1_INP2
H1_INP3
+24V DC
PGND

PIN
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16

FUNCTION
H3_M+
H3_M+12V DC
GND
HIGH LEVEL
LOW LEVEL
COIN OUT
N.C.
SECURITY
H3_INP1
H3_INP2
H3_INP3
+24V DC
PGND
+5V DC
N.C.

45M623N5UK-01

PIN
01
02
03
04
05
06

07 2008 AGI GmbH

HARDWARE

45M623N5UK-01

Connector X31
Main wire loom (46 pin female connector)
































PIN
A01
A02
A03
A04
A05
A06
A07
A08
A09
A10
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
A21
A22
A23
A24
A25
A26
A27
A28
A29
A30
A31
A32

07 2008 AGI GmbH

FUNCTION
GND
GND
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
GND
GND
IN13
IN14
IN15
IN16
IN17
IN18
IN19
IN20
GND
GND
IN21
IN22
IN23
IN24
IN25
IN26
IN27
IN28
+5V DC
+5V DC

PIN
C01
C02
C03
C04
C05
C06
C07
C08
C09
C10
C11
C12
C13
C14
C15
C16
C17
C18
C19
C20
C21
C22
C23
C24
C25
C26
C27
C28
C29
C30
C31
C32

FUNCTION
+12V-L
+12V-L
L1
LL2
L3
L4
L5
L6
L7
L8
+12V-L
+12V-L
L9
L10
L11
L12
L13
L14
L15
L16
+12V-L
+12V-L
L17
L18
L19
L20
L21
L22
L23
L24
+5V DC
+5V DC

P a g e
163

HARDWARE

V.7.5

If any defects occur, check whether all connectors are fixed correctly on the COOLFIRE backplane.

V.7.6

Troubleshooting

Exchange of the COOLFIRE Backplane

If any defects of the COOLFIRE backplane cannot be repaired, the defective part has to be exchanged.

45M623N5UK-01

Backplanetausch.eps

Illustr. V.7.2 Exchange of the COOLFIRE Backplane

Dismounting instructions for the COOLFIRE Backplane (see illustr. V.7.2):


1) Open the Main Door and disconnect the machine from the mains.
2) Dismount the COOLFIRE Motherboard (see part V - COOLFIRE Motherboard).
3) Remove the hopper cover and take out the hopper.
4) Release all connectors of the COOLFIRE backplane and loosen the fixing screws.
5) Unscrew the COOLFIRE backplane and take it out.
6) Assemble the COOLFIRE backplane in reverse order.

P a g e
164

07 2008 AGI GmbH

HARDWARE

V.8

Top light

Position in the machine

V.8.2

Function

V.8.3

Exchange of the top light

V.8.4

Exchange of the top light illumination

45M623N5UK-01

V.8.1

07 2008 AGI GmbH

P a g e
165

45M623N5UK-01

HARDWARE

There are static-sensitive parts inside the machine which could be damaged by electric
discharge. Ground yourself by touching a ground strap inside the machine to neutralize
electric charges before changing or maintaining inner parts.

P a g e
166

Ground straps inside the machine are marked


with yellow stickers as shown beside.
07 2008 AGI GmbH

HARDWARE

V.8.1

See illustr. V.0.1 on page 113.

V.8.2

Function

The top light indicates the different status of operation (jackpot, error, service...).

V.8.3

45M623N5UK-01

Position in the machine

Exchange of the top light

F_Lichtturm.JpG

Illustr. V.8.1 Top light

F_CS_LT_Schrauben.eps

Illustr. V.8.2 Fixing screw of the top light

Dismounting instructions for the top light:


1) Open the Main Door and disconnect the machine from the mains.
2) Open the lightbox frame.
3) Release the fixing screws of the connectors of the top light and exchange
the top light (see illustr. V.8.2).

07 2008 AGI GmbH

P a g e
167

HARDWARE

V.8.4

Exchange of the top light illumination

F_CS_LT_Teile.jpg

Dismounting instructions for the top light illumination:

The top light contains two lamps (T10 12V 2W).


1) Open the Main Door and disconnect the machine from the mains.
2) Release the nuts of the upper cover of the top light and remove the covers (see illustr. V.8.3).
3) Exchange the defective lamp.
4) Assemble in reverse order.

P a g e
168

07 2008 AGI GmbH

45M623N5UK-01

Illustr. V.8.3 Components of the top light

HARDWARE

V.9

Illumination

Bill acceptor illumination

V.9.2

Key illumination

V.9.3

Door in door illumination

V.9.4

Lightbox illumination

45M623N5UK-01

V.9.1

07 2008 AGI GmbH

P a g e
169

45M623N5UK-01

HARDWARE

There are static-sensitive parts inside the machine which could be damaged by electric
discharge. Ground yourself by touching a ground strap inside the machine to neutralize
electric charges before changing or maintaining inner parts.

P a g e
170

Ground straps inside the machine are marked


with yellow stickers as shown beside.
07 2008 AGI GmbH

HARDWARE

V.9.1

Bill acceptor illumination

V.9.1.1 Position in the machine


See illustr. V.0.1 on page 113.

V.9.1.2 Function

Blue illumination: bill acceptor is ready


Red illumination: bill acceptor is out of order

F_BNP_Bel.jpg

45M623N5UK-01

Illustr. V.9.1 Bill acceptor illumination

V.9.1.3 Exchange of the bill acceptor illumination

F_BNP_Beleuchtung.eps

Illustr. V.9.2 Bill acceptor illumination circuit board

07 2008 AGI GmbH

P a g e
171

HARDWARE

Dismounting instructions for the bill acceptor illumination:

The bill acceptor illumination is located on a circuit board inside the Main Door (see illustr. V.9.2).

45M623N5UK-01

1) Open the Main Door and disconnect the machine from the mains.
2) Disconnect the plug connections and remove the complete circuit board by unscrewing both nuts.
3) Exchange the unit, tighten the nuts and connect the cable connection with the circuit board.

P a g e
172

07 2008 AGI GmbH

HARDWARE

V.9.2

Key illumination

V.9.2.1 Position in the machine


See illustr. V.0.1 on page 113.

V.9.2.2 Function

The key illumination shows the active buttons during game playing. If the machine is not equipped
with a touchscreen, the functions of the bookkeeping are activated via the respectively illuminated buttons.

F_BNP_Bel.jpg

45M623N5UK-01

Illustr. V.9.3 Keyboard with illuminated button

V.9.2.3 Exchange of the key illumination


1) Open the Main Door and disconnect the machine from the mains.
2) Turn the lamp base of the defective lamp down and take out the lamp.
3) Exchange the lamp, press the base into the bracket, switch on the machine
and close the Main Door.

07 2008 AGI GmbH

P a g e
173

HARDWARE

V.9.3

Door in door illumination

V.9.3.1 Position in the machine


See illustr. V.0.1 on page 113.

V.9.3.2 Function

Fluorescent tube F15 W/133 (cold cathode)


Starter S2 4-22 W for 220 - 240 V resp. FS-2x for 110 V

45M623N5UK-01

V.9.3.3 Exchange of the door in door illumination

F_623_Lampen DiD_TIPR.jpg

Illustr. V.9.4 Door in door, open

Dismounting instructions for the door in door illumination:


1) Open the Main Door and disconnect the machine from the mains.
2) Open the door in door system.
3) Turn the defective fluorescent tube 90, take it out of its base and exchange it.
4) Assemble the illumination system in reverse order.

The starter for the fluorescent tube is located inside the machine down left at the housing.

P a g e
174

07 2008 AGI GmbH

HARDWARE

V.9.4

Lightbox illumination

V.9.4.1 Position in the machine


See illustr. V.0.1 on page 113.

V.9.4.2 Function

Fluorescent tube F15 W/133 (cold cathode)


Starter S2 4-22 W for 220 - 240 V resp. FS-2x for 110 V

45M623N5UK-01

V.9.4.3 Exchange of the lightbox illumination

F_623_Lichtkasten_offen.jpg

Illustr. V.9.5 Lightbox, open

F_623_Lichtkastenbeleuchtung.jpg

Illustr. V.9.6 Starter

Dismounting instructions for the lightbox illumination:


1) Open the Main Door and disconnect the machine from the mains.
2) Pull out the lightbox in forward direction.
3) Turn the defective fluorescent tube 90, take it out of its base and exchange it.
4) Assemble the illumination system in reverse order.

The starter for the fluorescent tube in the lightbox is located beside the fluorescent tube.

07 2008 AGI GmbH

P a g e
175

45M623N5UK-01

HARDWARE

P a g e
176

07 2008 AGI GmbH

HARDWARE

V.10

Mechanical meters

Position in the machine

V.10.2

Function

V.10.3

Troubleshooting

V.10.4

Exchange of the meters

45M623N5UK-01

V.10.1

07 2008 AGI GmbH

P a g e
177

45M623N5UK-01

HARDWARE

There are static-sensitive parts inside the machine which could be damaged by electric
discharge. Ground yourself by touching a ground strap inside the machine to neutralize
electric charges before changing or maintaining inner parts.

P a g e
178

Ground straps inside the machine are marked


with yellow stickers as shown beside.
07 2008 AGI GmbH

HARDWARE

V.10.1 Position in the machine


See illustr. V.0.1 on page 113.

V.10.2 Function
These mechanical meters represent the respective values of the machine accounting.

IN

OUT

BET

WIN

GAMES

REMOTE

HANDPAY

BILLS

45M623N5UK-01

Z_Zhlwerke.eps

IN
OUT
BET
WIN
GAMES
REMOTE
HANDPAY
BILLS

Total value of all coins and bills inserted and credits added via the remote function.
Total value of all credits paid out (hopper and handpay).
Total value of all bets in credits.
Total value of all wins in credits.
Total value of all games played.
Total value of all credits added via the remote function.
Total value of all credits paid out via handpay.
Total value of all bills inserted in credits.

V.10.3 Troubleshooting


Check the connectors of the meter unit.


If an error message is triggered by a malfunction or non-activation of individual meters the device
must be removed from operation and the meters circuit board must be exchanged.

07 2008 AGI GmbH

P a g e
179

HARDWARE

V.10.4 Exchange of the meters


If any defects cannot be repaired, the defective meter has to be exchanged.

F_623_Position Zaehlwerke.jpg

Illustr. V.10.1 Position of the meters

F_623_Zaehlwerktausch.jpg

Illustr. V.10.2 Exchange of the meters

Dismounting instructions for the meters:

45M623N5UK-01

1) Open the Main Door and disconnect the machine from the mains.
2) Unscrew the meter cover (see illustr. V.10.2).
3) Disconnect the main plug of the meters.
4) Unscrew the meter unit and exchange it.
5) Assemble the meter unit in reverse order.

P a g e
180

07 2008 AGI GmbH

HARDWARE

V.11

Door optics/switches

Position in the machine

V.11.2

Function

V.11.3

Troubleshooting

V.11.4

Exchange of the door optics/switches

45M623N5UK-01

V.11.1

07 2008 AGI GmbH

P a g e
181

45M623N5UK-01

HARDWARE

There are static-sensitive parts inside the machine which could be damaged by electric
discharge. Ground yourself by touching a ground strap inside the machine to neutralize
electric charges before changing or maintaining inner parts.

P a g e
182

Ground straps inside the machine are marked


with yellow stickers as shown beside.
07 2008 AGI GmbH

HARDWARE

V.11.1 Position in the machine


See illustr. V.0.1 on page 113.

V.11.2 Function

The door optics/switches monitor the openings and closings of the machine doors.

V.11.3 Troubleshooting

Check the connectors of the optic boards/switches for any damages.

V.11.4 Exchange of the door optic boards/switch


If any defects cannot be repaired, the defective door optic board/switches have to be exchanged.

45M623N5UK-01

F_Trschalter.eps

35500583.jpg

Illustr. V.11.1 Exchange of the door switch resp. the door switch board

Dismounting instructions for door switches:


1) Open the Main Door and disconnect the machine from the mains.
2) Release the plug connectors of the defective door switch.
3) Unscrew the fixing screws and remove the door switch.
4) Exchange the defective door switch.
5) Assemble in reverse order.

07 2008 AGI GmbH

P a g e
183

HARDWARE

receiver

transmitter

F_623CF_Tuersensor_Gehaeuse.jpg
F_623CF_Tuersensor_Tuer.jpg

Illustr. V.11.2 Exchange of the door optic boards

Dismounting instructions for door optic boards:

45M623N5UK-01

1) Open the Main Door and disconnect the machine from the mains.
2) Release the hexagon screws and the connectors and exchange the defective board.

P a g e
184

07 2008 AGI GmbH

HARDWARE

V.12

Loudspeakers

Position in the machine

V.12.2

Volume control

V.12.3

Troubleshooting

45M623N5UK-01

V.12.1

07 2008 AGI GmbH

P a g e
185

45M623N5UK-01

HARDWARE

There are static-sensitive parts inside the machine which could be damaged by electric
discharge. Ground yourself by touching a ground strap inside the machine to neutralize
electric charges before changing or maintaining inner parts.

P a g e
186

Ground straps inside the machine are marked


with yellow stickers as shown beside.
07 2008 AGI GmbH

HARDWARE

V.12.1 Position in the machine


See illustr. V.0.1 on page 113.

V.12.2 Volume control


Loudspeaker: 8 Ohm, 10 W

F_623CF_LS_MainDoor.jpg

F_623CF_Monitormaske.jpg

Illustr. V.12.2 Loudspeakers in the monitor mask

45M623N5UK-01

Illustr. V.12.1 Loudspeakers in the Main Door (bottom)

F_623CF_Lautstaerke.jpg

Illustr. V.12.3 Volume control

V.12.3 Troubleshooting

Check the connectors of the loudspeakers and the potentiometer.

Loudspeaker left:
Loudspeaker rights:

If any defects of the loudspeakers cannot be repaired, exchange the defective part.

07 2008 AGI GmbH

+ red/black
+ orange/green

- orange/black
- orange/black

P a g e
187

45M623N5UK-01

HARDWARE

P a g e
188

07 2008 AGI GmbH

HARDWARE

45M623N5UK-01

07 2008 AGI GmbH

V.13

Preventative maintenance

V.13.1

Bill acceptor

V.13.2

Coin acceptor (optics)

V.13.3

Door optics

V.13.4

Monitor / Touchscreen

V.13.5

Maintenance intervals

P a g e
189

45M623N5UK-01

HARDWARE

Before starting any maintenance work make sure, that the machine is disconnected from the mains by
pulling the power plug out of the socket.
The following service instructions are for use by qualified or trained personnel only.
To avoid personal injury or damage to the equipment, do not perform any servicing other
than such contained in this manual.
If you follow these instructions closely and the machine is maintained and handled in a proper way, it
complies with the usual safety standards.
Periodic cleaning prevents a lot of failures.

There are static-sensitive parts inside the machine which could be damaged by electric
discharge. Ground yourself by touching a ground strap inside the machine to neutralize
electric charges before changing or maintaining inner parts.

P a g e
190

Ground straps inside the machine are marked


with yellow stickers as shown beside.
07 2008 AGI GmbH

HARDWARE

ATTENTION

To avoid excessive errors perform the cleaning procedures with recommended frequency.
Never use a water jet to clean the device!

V.13.1 Bill acceptor


Cleaning:

reader sensors

45M623N5UK-01

magnetic sensor

reader sensors

F_WBA_Reinigung1.eps

Illustr. V.13.2 Cleaning of the bill acceptor

F_WBA_Reinigung2.eps

Illustr. V.13.1 Bill acceptor, open

Description:

If reader sensors or magnetic sensors are dirty this may result in error messages as when bills are jammed,
or the identification precision may increase, which may result in bills being rejected more frequently.
To clean the reader head / magnetic sensor use a soft cloth or cotton bud.
If necessary, a standard head cleaner for cassette recorder can be used.

ATTENTION

Do not use organic solvent like thinner!


Do not use abrasive materials!

Recommended maintenance interval: monthly

If bill acceptance does not improve after cleaning the sensors may require re-adjusting.

CLEANING

Cleaning towels for the WBA bill acceptor are available from AGI (Cleaning card kit).

07 2008 AGI GmbH

P a g e
191

HARDWARE

V.13.2 Coin acceptor (optics)


Cleaning of the coin acceptor NRI / MC-40:


1) Optics:
To clean the optics inside the coin acceptor take out the coin acceptor.
To do so unclick the front cover and take out the coin acceptor PCB.
Clean the optics on the back with compressed air (do not exceed 60 psi).
Perform the same operation on the optics located on the back of the coin acceptor.
2) Thorough cleaning:
Remove the coin acceptor.
Clean the outside of the coin acceptor with a short-hair brush and with isopropyl alcohol.
Remove the sample coin from the sample coin holder unit.
Clean the inside of the coin acceptor using a spray-on contact cleaner or a short-hair brush.
Replace the sample coin. Insert the coin acceptor into the coin acceptor holder.
3) Cleaning of the coin optics board:

45M623N5UK-01

Open the fixing screw of the coin optics board. Clean the optics with a short-hair brush or a cotton bud
and with isopropyl alcohol. Be careful not do bend the optics. Re-install the coin optics board.

F_Mnzprfer_ausgebaut.eps

Illustr. V.13.3 Coin optics board NRI

F_Mnzkanallichtschranke.eps

Illustr. V.13.4 Coin optics board MC-40

ATTENTION

Do not use organic solvent like thinner! Do not use abrasive materials!

Recommended maintenance interval: 3-monthly

NOTE

Make sure that the sensors are adjusted properly and that there are no obstructions
in the optical transmission distance between the transmitter and the receiver.

P a g e
192

07 2008 AGI GmbH

HARDWARE

V.13.3 Door optics


Description:

If the machine has many errors of the Main Door, clean the door optics with a short-hair brush
or a cotton bud and with isopropyl alcohol.
To re-align the optics the fixing screws have to be loosened.

receiver

transmitter

45M623N5UK-01

F_623CF_Tuersensor_Gehaeuse.jpg
F_623CF_Tuersensor_Tuer.jpg

Illustr. V.13.5 Cleaning of the door optics

Recommended maintenance interval: semi-yearly

V.13.4 Monitor / Touchscreen


Description:

The touchscreen should be cleaned at least once a week using a soft cloth and window cleaner.
In addition, the touchscreen requires regular calibration, which will depend on how much it is
used but should at least be done once a week. When calibrating the touchscreen make sure that
you are looking at the screen straight from above (from the players seated position!) and are not
touching the metal cabinet of the terminal with your body.

Recommended maintenance interval: weekly

07 2008 AGI GmbH

P a g e
193

HARDWARE

V.13.5 Maintenance intervals


Machine part

Interval

Bill acceptor
Coin acceptor
Door optics
Reel light barrier
Lamps of the reel unit
Reel axis O-rings
Monitor / Touchscreen
Ticket printer EPIC 950 (print head)

monthly
3-monthly
semi-yearly
semi-yearly
semi-yearly
after 200.000 games played or after 3 years
weekly
3-monthly

45M623N5UK-01

P a g e
194

07 2008 AGI GmbH

Annex
Table of Illustrations

45M623N5UK-01

Glossary

Austrian Gaming Industries GmbH


07 2008 AGI GmbH Wiener Strasse 158 . A-2352 Gumpoldskirchen . Austria . Europe . Tel.: +43-2252-606 . www.austrian-gaming.com . e-mail: support@novomatic.com

45M623N5UK-01

ANNEX

P a g e
196

07 2008 AGI GmbH

ANNEX

45M623N5UK-01

Table of Illustrations
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.

0.1
I.1.1
I.2.1
I.3.1
II.2.1
II.2.2
III.1.1
III.2.1
IV.1.1
IV.1.2
IV.1.3
IV.9.1
V.0.1
V.0.2
V.1.1
V.2.1
V.2.2
V.2.3
V.2.4
V.2.5
V.2.6
V.2.7
V.2.8
V.2.9
V.2.10
V.3.1
V.3.2
V.3.3
V.3.4
V.4.1
V.5.1
V.5.2
V.5.3
V.6.1
V.6.2
V.6.3
V.6.4
V.6.5
V.7.1
V.7.2
V.8.1
V.8.2
V.8.3

07 2008 AGI GmbH

ID Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Operating elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Description of components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Machine dimensions FV-623 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Drilling jig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Drilling scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Main switch with fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Error display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Attendant keyswitch for error handling . . . . . . . . . . . . . . . . . . . . . . . . 27
Internal error - Screenshot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Error message - Explanation of elements . . . . . . . . . . . . . . . . . . . . . . 28
Position OF DIP switch 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Description of components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Switching power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Lock bar of the bill acceptor WBA-25-SS2 . . . . . . . . . . . . . . . . . . . . . 121
Bill acceptor Cashflow SC83 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
Exchange of the bill acceptor Cashflow SC83 . . . . . . . . . . . . . . . . . . . 122
Components Cashflow SC83 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Components WBA-25-SS2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Collecting bills - WBA-25-SS2 . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Collecting bills - Cashflow SC83 . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Removing jammed bills - WBA-25-SS2 . . . . . . . . . . . . . . . . . . . . . . . 124
Removing jammed bills - Cashflow SC83 . . . . . . . . . . . . . . . . . . . . . 124
Acceptor unit of the bill acceptor . . . . . . . . . . . . . . . . . . . . . . . . . . 125
Exchange of the coin acceptor NRI-G13 . . . . . . . . . . . . . . . . . . . . . . 130
Exchange of the coin comparitor MC-40 . . . . . . . . . . . . . . . . . . . . . . 130
Programming of the coin acceptor NRI-G13 . . . . . . . . . . . . . . . . . . . . 131
DIL switch on coin acceptor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
Exchange of the hopper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
Exchange of the lower monitor (FV-623) . . . . . . . . . . . . . . . . . . . . . . 141
Exchange of the upper monitor (FV-623) . . . . . . . . . . . . . . . . . . . . . . 142
Buttons for adjustment of the screen . . . . . . . . . . . . . . . . . . . . . . . . 143
Exchange of the mainboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
DIP switch position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Position game selector (1), game software (2), EEPROM (3) . . . . . . . . . . . 149
Exchange of the game software . . . . . . . . . . . . . . . . . . . . . . . . . . 150
Correct insertion position of the EEPROM . . . . . . . . . . . . . . . . . . . . . 150
Pin assignment COOLFIRE backplane . . . . . . . . . . . . . . . . . . . . . . . 153
Exchange of the COOLFIRE Backplane . . . . . . . . . . . . . . . . . . . . . . 164
Top light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
Fixing screw of the top light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
Components of the top light . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168

Page 197

ANNEX

V.9.1
V.9.2
V.9.3
V.9.4
V.9.5
V.9.6
V.10.1
V.10.2
V.11.1
V.11.2
V.12.1
V.12.2
V.12.3
V.13.1
V.13.2
V.13.3
V.13.4
V.13.5

Bill acceptor illumination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171


Bill acceptor illumination circuit board . . . . . . . . . . . . . . . . . . . . . . . 171
Keyboard with illuminated button . . . . . . . . . . . . . . . . . . . . . . . . . . 173
Door in door, open . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174
Lightbox, open . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
Starter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
Position of the meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
Exchange of the meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
Exchange of the door switch resp. the door switch board . . . . . . . . . . . . . 183
Exchange of the door optic boards . . . . . . . . . . . . . . . . . . . . . . . . . 184
Loudspeakers in the Main Door (bottom) . . . . . . . . . . . . . . . . . . . . . . 187
Loudspeakers in the monitor mask . . . . . . . . . . . . . . . . . . . . . . . . . 187
Volume control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187
Bill acceptor, open . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
Cleaning of the bill acceptor . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
Coin optics board NRI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
Coin optics board MC-40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
Cleaning of the door optic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193

45M623N5UK-01

Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.
Illustr.

Page 198

07 2008 AGI GmbH

ANNEX

Glossary


Bill acceptor

Device used for checking and collecting or denying banknotes


or printed tickets.


Bill acceptor channel

The bill acceptor has various software channels, which are used for
recognition of different bills. Each channel is programmed for a single
type of bill.


Booksize PC

Personal computer in DIN A4 format. Manages all functions of the


the machine. A keyboard can be connected for inputting data.

45M623N5UK-01

Calibration

Function used to set the display precision for touchscreens.


Cancel Credit

Equivalent to handpay. The credit is cancelled from the machine, and is


paid out by the operator or attendant.


Coin channel

The coin acceptor has various software channels, which are used for
recognition of different coins. Each channel is programmed for a single
type of coin.


DIP/DIL switch

Dual in-line package switch; a number of microswitches on a bracket.


Different settings are possible which depend on the position of the
switches.

Dongle

Special connector used as to copy-protected software.


Gamble Function

Grounding strap

Handpay

Game function to double wins. This function is embedded in the game,


and is accessed during present phases of the game.
Metallic, non-isolated cable, used to balance electric potentials.


Hopper

Payout of wins or credits by an attendant or operator.


Coin dispenser; coins for payout of wins or credits are collected in
the hopper

07 2008 AGI GmbH

P a g e
199

ANNEX

Jackpot

Keycode

Bets collected to a stock until a player reaches the win criteria.

Security code, used for repairs purposes.


LED

Light Emitting Diode; light source based on semiconductor technique.


Features high mechanical rigidity and an extremely long life.


Mechanical meters

Mechanic device counting recurring actions, like coin insertions,


remotes or wins.

Pin

Power switching unit

Unit supplying voltage to the logic unit of the machine.

Push up

Book credit to a game. Carried out by the operator.

Connector, plug.

45M623N5UK-01


Reference coin

Remote

The coin is used in the coin comparitor to check the validity of


inserted coins.
Function used to book credits.


Reset

This function is used to clear the whole machine software. All


bookkeeping statistics and all user-specific settings are cleared and
set to Zero or to their default values.


ROM


Abr. for: Read Only Memory; A type of memory that can be read but not
written in normal operation. Special techniques are required to initialize
the contents of a ROM, which are usually considered permanent and is
powered by a small long-life battery.

P a g e
200

07 2008 AGI GmbH

ANNEX


Sorter

Coin deviator; depending on the position of the sorter, coins are


collected in the hopper or in the cashbox.


Stand-by

Sleeping mode, into which the machine changes when no game is


being played.


Test switch

Used for calling the Test Menu. The test switch is located inside the
machine.


TFT

Thin film transistor; a liquid crystal monitor. Every bitpoint is driven by a


transistor. Best resolution results are obtained with TFT displays.


Ticket printer

Printing unit, used for printing credit tickets, which can be used to cash
wins or for moneyless payout purposes.

45M623N5UK-01

Token


Touchscreen

Credit coin, used instead of money during games.


Touch-sensitive monitor. Certain functions can be accessed by touching
the buttons displayed directly on the monitor.

Zapper error

Suspicion of manipulation.

07 2008 AGI GmbH

P a g e
201

45M623N5UK-01

ANNEX

P a g e
202

07 2008 AGI GmbH

FEEDBACK FORM

Please spare some minutes of your time to answer the following questions as precisely as possible
and send the form back to us.
You can reach us
by phone under +43 2252 606 300,

by fax under +43 2252 607 001. You can also

send us an E-mail to support@novomatic.com.

1.) Were you satisfied with the execution of the order?

If NO, please indicate why.

2.)

NO
c

If YES, please indicate the damage.

Were there any problems during the setting into operation


of the machine?
If YES, please indicate.

45M623N5UK-01

3.)

Have the machines been damaged during transport?

YES
c

4.)

5.)

6.)

7.)

Are there any serious problems during the game operation?


If YES, please indicate.

Are you satisfied with the software functions?


If NO, please indicate suggestions for improvement?

Are you satisfied with the error handling?


If NO, please indicate suggestions for improvement?

Are you satisfied with the cash handling?


If NO, please indicate suggestions for improvement?

07 2008 AGI GmbH

Page 203

FEEDBACK FORM


8.) Do you think that the machine is user-optimized?

If NO, please indicate suggestions for improvement?

YES
c

NO
c

10.) Are you satisfied with the spare parts supply?



If NO, please indicate why.

11.) Are you satisfied with our Technical Support?



If NO, please indicate why.

12.) Are our machines attractive for the players?



If NO, please indicate why.

13.) Other general suggestions for improvement:

Are you satisfied with the hardware?


If NO, please indicate suggestions for improvement?

45M623N5UK-01

9.)

Remitter:

Thank you!
P a g e
204

07 2008 AGI GmbH

ELEK38010094-3.xls / Plug-Pinning

Plug Pinning: Hauptkabelbaum Classic Streamline & Diplomat Streamline


CSL-622,DSL 623
Art.Nr: 38010094-3
Stecker 01 : 64pol. VG-Federleiste; Art.Nr:13350032 (AMP: 925 486-1)
Pin

colour

Farbe

qmm

01a
01c
02a
02c
03a
03c
04a
04c
05a
05c
06a
06c
07a
07c
08a
08c
09a
09c
10a
10c
11a
11c
12a
12c
13a
13c
14a
14c
15a
15c
16a
16c
17a
17c
18a
18c
19a
19c
20a
20c
21a
21c
22a
22c
23a
23c
24a
24c

red
red
nc
nc
nc
nc
violet/brown
white/violet
white/orange
yellow/blue
white/black
red/blue
brown/black
grey/black
pink/blue
grey
green/black
grey/violet
pink
white/blue
orange/black
yellow
orange/black
yellow
blue/black
brown/blue
orange/brown
pink/brown
grey/green
yellow/violet
blue/violet
pink/grey
white/yellow
white/red
yellow/red
violet/black
yellow/pink
pink/orange
pink/black
red/black

rot
rot
nc
nc
nc
nc
violett/braun
wei/violett
wei/orange
gelb/blau
wei/schwarz
rot/blau
braun/schwarz
grau/schwarz
rosa/blau
grau
grn/schwarz
grau/violett
rosa
wei/blau
orange/schwarz
gelb
orange/schwarz
gelb
blau/schwarz
braun/blau
orange/braun
rosa/braun
grau/grn
gelb/violett
blau/violett
rosa/grau
wei/gelb
wei/rot
gelb/rot
violett/schwarz
gelb/rosa
rosa/orange
rosa/schwarz
rot/schwarz

orange/black

orange/schwarz

nc

nc

orange/black

orange/schwarz

nc
brown/grey
nc
green /brown
nc

nc
braun/grau
nc
grn/braun
nc

0.35
0.35
***
***
***
***
0.35
0.35
0.50
0.35
0.50
0.35
0.50
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.5
0.5
0.35
0.5
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.5
0.35
0.5
0.35
0.5
0.35
***
0.5
***
0.35
***
0.35
***

AGI
2352 Gumpoldskirchen
Wiener Strae 158

Funktion
+5VDC fr OP-S
+5VDC fr OP-R
***
***
***
***
RESERVE
RESERVE
Schlsselschalter 3 (TEST)
PLAY 7 LINES
Schlsselschalter 2 (AUDIT)

PLAY 5 LINES
Schlsselschalter 1 (ATTENDANT)

BET 2 PER LINE


doorswitch (receiver)
PLAY 3 LINES
doorswitch (door in door)
BET 1 PER LINE
doorswitch (BNP)
PLAY 1 LINE
GND
+12VDC fr Toplight
GND
+12VDC fr Hebeleinheit
doorswitch (drop)
SERVICE
SERVICE
COLLECT
COLLECT
PLAY 9 LINES
PLAY 9 LINES
doorswitch (transmitter)
AUTO START
enable lever
TAKE WIN
toplight (reserve)
GAMBLE
toplight (blue)
BET 10 PER LINE
toplight (white)
GND
***
GND
***
BET 5 PER LINE
***
BET 3 PER LINE
***

Funktion-allg.

Treiber

kurz. Bezeichnung

VCC +5VDC
VCC +5VDC
VCC +5VDC
VCC +5VDC
INPUT 28
OUTPUT 24
INPUT 27
OUTPUT 23
INPUT 26
OUTPUT 22
INPUT 25
OUTPUT 21
INPUT 24
OUTPUT 20
INPUT 23
OUTPUT 19
INPUT 22
OUTPUT 18
INPUT 21
OUTPUT 17
GND
+12VDC
GND
+12VDC
INPUT 20
OUTPUT 16
INPUT 19
OUTPUT 15
INPUT 18
OUTPUT 14
INPUT 17
OUTPUT 13
INPUT 16
OUTPUT 12
INPUT 15
OUTPUT 11
INPUT 14
OUTPUT 10
INPUT 13
OUTPUT 9
GND
+12VDC
GND
+12VDC
INPUT 12
OUTPUT 8
INPUT 11
OUTPUT 7

***
***
***
***
***

***
***
***
***
S22
H22
S21
H21
KEY3
H06
KEY2
H05
KEY1
H04
ST02
H03
S18
H02
S17
H01
***
***
***
***
S16
H15
S15
H14
S14
H13
S13
ST04
S12
ST03
S11
H20
S10
H19
S09
H18
***
***
***
***
S08
***
S07
***

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

ULN2064
ULN2064
ULN2064
ULN2064
ULN2064
ULN2064
ULN2064
ULN2064

***
***
***
***
***
ULN2803

***
ULN2803
ULN2803
ULN2803
ULN2803
ULN2803
ULN2803
ULN2803

***
***
***
***
***
ULN2803
ULN2803

Erstellt von Geischlger


nderungsstand: 03
Seite 1 von 10

ELEK38010094-3.xls / Plug-Pinning
25a
25c
26a
26c
27a
27c
28a
28c
29a
29c
30a
30c
31a
31c
32a
32c

yellow/brown
white/grey
red/brown
red/grey
yellow/black
orange/violet
red/violet
white/brown
yellow/grey
blue/grey
pink/violet
blue/green
orange/black
yellow
orange/black
yellow

gelb/braun
wei/grau
rot/braun
rot/grau
gelb/schwarz
orange/violett
rot/violett
wei/braun
gelb/grau
blau/grau
rosa/violett
blau/grn
orange/schwarz
gelb
orange/schwarz
gelb

0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.5
0.5
0.5
0.5

PLAY 7 LINES
START
PLAY 5 PER LINE
TAKE WIN
BET 2 PER LINE
GAMBLE
PLAY 3 PER LINES
BET 10 PER LINES
BET 1 PER LINE
BET 5 PER LINE
PLAY 1 LINE
BET 3 PER LINE
GND fr Tasten
+12VDC fr Lampen
GND fr Tasten
+12VDC fr Lampen

INPUT 10
OUTPUT 6
INPUT 9
OUTPUT 5
INPUT 8
OUTPUT 4
INPUT 7
OUTPUT 3
INPUT 6
OUTPUT 2
INPUT 5
OUTPUT 1
GND
+12VDC
GND
+12VDC

***
***
***
***

S06
H12
S05
H11
S04
H10
S03
H09
S02
H08
S01
H07
GND
+12VDC
GND
+12VDC

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***
***
***

***
***
***
***

+5VDC
OP-R
GND
***

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***
***
***

***
***
***
***

***
START
GND
+12VDC

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***
***
***

***
***
***
***

+5VDC
OP-S
***
***

ULN2803
ULN2803
ULN2803
ULN2803
ULN2803
ULN2803

(Anschlu an P369 Lichtschranke Empfnger)


Stecker 02: 4pol. Molex Buchsengehuse; (1-reihig) RM2,54 Art.Nr:13100014 (Molex 22-01-2045)
Pin
01
02
03
04

colour

Farbe

red
rot
pink/blue
rosa/blau
orange/black orange/schwarz
nc
nc

qmm

Funktion

0.35
0.35
0.35

+5VDC
doorswitch (receiver)
GND
***

(Anschlu an Hebeleinheit)
Stecker 03: 4pol. MINI-FIT Buchsengehuse Art.Nr:13100026 (Molex Nr:39-01-2040)
Pin
01
02
03
04

colour

Farbe

white/red
wei/rot
white/yellow
wei/gelb
orange/black orange/schwarz
yellow
gelb

qmm
0.35
0.35
0.35
0.5

Funktion
enable lever (Freigabe)
S12 (START)
GND
+12VDC

(Anschlu an P368 Lichtschranke Sende-Diode)


Stecker 04: 4pol. Molex Buchsengehuse; (1-reihig) RM2,54 Art.Nr:13100014 (Molex 22-01-2045)
Pin

colour

Farbe

qmm

01
02
03
04

red
pink/grey
nc
nc

rot
rosa/grau
nc
nc

0.35
0.35

AGI
2352 Gumpoldskirchen
Wiener Strae 158

Funktion
+5VDC
doorswitch (transmitter diode)
***
***

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

Erstellt von Geischlger


nderungsstand: 03
Seite 2 von 10

ELEK38010094-3.xls / Plug-Pinning
(Walzenversorgung)
Stecker 05: 6pol. Mini-Fit Buchsengehuse; Art.Nr:13100029 (Molex 39-01-2060)
Pin

colour

Farbe

qmm

01
02
03
04
05
06

green
black
yellow
black
white
black

grn
schwarz
gelb
schwarz
wei
schwarz

1.0
1.0
1.0
1.0
1.0
1.0

Funktion
+24VDC(S)
GND(S)

+12VDC(S)
GND(S)

+12VDC(R)
GND(R)

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***
***
***
***
***

***
***
***
***
***
***

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***

***
***

***
***

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***
***
***

***
***
***
***

+12VDC
H19
H18
H20

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***
***
***
***
***
***
***
***
***
***
***
***
***
***
***
***
***

***
***
***
***
***
***
***
***
***
***
***
***
***
***
***
***
***
***

+5VDC
+5VDC
+5VDC
GND
GND
+12VDC
+12VDC
+12VDC
+24VDC
+5VDC
+5VDC
GND
GND
-12VDC
(Option +12VDC)
(Option +12VDC)
PFD
+24VDC

+24VDC(S)
GND(S)

+12VDC(S)
GND(S)

+12VDC(R)
GND(R)

(Touchscreen)
Stecker 06: 2pol. Molex Stiftgehuse; Art.Nr:13050002 (Molex 03-09-2021)
Pin

colour

Farbe

qmm

01
02

black
yellow

schwarz
gelb

1.0
1.0

Funktion
GND
+12VDC

(Toplightstecker)
Stecker 07: 4pol MOLEX Buchsengehuse; Art.Nr: 13100002 (Molex Nr:03-09-1040)
Pin
01
02
03
04

colour

Farbe

yellow
gelb
pink/orange
rosa/orange
red/black
rot/schwarz
violet/black violett/schwarz

qmm
0.5
0.5
0.5
0.5

Funktion
+12VDC
toplight (blau)
toplight (wei)
toplight (reserve)

(=rot)
(=gelb)
(=grn)

(Anschlu am NFS-Adapter-NGC)
Stecker 08: 18pol MOLEX Mini-Fit Stiftgehuse; Art.Nr:13100036 (Molex Nr:39-01-2181)
Pin

colour

Farbe

qmm

01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18

red
red
red
black
black
yellow
yellow
yellow
green
red
red
black
black
violet
nc
nc
orange
green

rot
rot
rot
schwarz
schwarz
gelb
gelb
gelb
grn
rot
rot
schwarz
schwarz
violett
nc
nc
orange
grn

1.0
1.0
0.5
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
***
***
0.5
1.0

AGI
2352 Gumpoldskirchen
Wiener Strae 158

Funktion
+5VDC
+5VDC
+5VDC
GND (Ringkern - NFS)
GND (Sternpunkt)
+12VDC (fr Backplane)
+12VDC (fr Sternpunkt)
+12VDC (fr Backplane)
+24VDC (fr Sternpunkt)
+5VDC
+5VDC
GND (fr Backplane)
GND (fr Backplane)
-12VDC
***
***
PFD
+24VDC (fr Backplane)

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

Erstellt von Geischlger


nderungsstand: 03
Seite 3 von 10

ELEK38010094-3.xls / Plug-Pinning
(Anschlu am Modularnetzteil)
Stecker 09: 6pol MOLEX Buchsengehuse Mini-Fit; Art.Nr: 13100029 (Molex Nr:39-01-2060)
Pin

colour

Farbe

qmm

01
02
03
04
05
06

white
white
white
black
black
black

wei
wei
wei
schwarz
schwarz
schwarz

1.0
1.0
1.0
1.0
1.0
0.5

Funktion

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***
***
***
***
***

***
***
***
***
***
***

+12VDC
+12VDC
+12VDC
GND
GND
GND

Funktion-allg.

Treiber

kurz. Bezeichnung

***

***

+12VDC

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***
***
***
***
***
***
***
***
***
***
***

***
***
***
***
***
***
***
***
***
***
***
***

+5VDC
GND
+12VDC
GND
+24VDC
GND
+5VDC
nc
+12VDC
nc
PFD
-12VDC

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***

***
***

+12VDC
nc

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***
***
***

***
***
***
***

audio-rechts
audio-GND
audio-links
audio-GND

+12VDC
+12VDC (Sternpunkt)
+12VDC
GND
GND
GND

(Anschlu fr Walzenprint P331-1)


Stecker 11: 6.3mm Fast-On, Art.Nr: 13800004 (AMP 5-160 432-3) oder Seno Nr.
Pin

colour

Farbe

qmm

white

wei

1.0

Funktion
+12VDC

(Anschlu an Backplane, Backplaneversorgung)


Stecker 12: 12pol MOLEX Buchsengehuse Mini-Fit; Art.Nr: 13100032 (Molex Nr:39-01-2120)
Pin

colour

Farbe

qmm

01
02
03
04
05
06
07
08
09
10
11
12

red
black
white
black
green
black
red
nc
yellow
nc
orange
violet

rot
schwarz
wei
schwarz
grn
schwarz
rot
nc
gelb
nc
orange
violett

1.0
1.0
1.0
1.0
1.0
1.0
1.0
***
1.0
***
0.5
1.0

Funktion
+5VDC
GND
+12VDC (Trafo)
GND
+24VDC
GND
+5VDC
nc
+12VDC
nc
PFD
-12VDC

(Optionaler Anschlu fr ST12/Pin03)


Stecker 13: 2pol. Molex Buchsengehuse Mini-Fit; Art.Nr:13100053 (Molex 39-01-2020)
Pin

colour

Farbe

qmm

01
02

yellow
nc

gelb
nc

1.0
***

Funktion
+12VDC
nc

(Anschlu an Backplane, Lautsprecher [X16])


Stecker 14: 4pol MOLEX Buchsengehuse Mini-Fit; Art.Nr: 13100026 (Molex Nr:39-01-2040)
Pin
01
02
03
04

colour

Farbe

red/black
rot/schwarz
orange/black orange/schwarz
orange/green orange/grn
orange/black orange/schwarz

AGI
2352 Gumpoldskirchen
Wiener Strae 158

qmm
0.35
0.35
0.35
0.35

Funktion
audio-rechts
GND
audio-links
GND

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

Erstellt von Geischlger


nderungsstand: 03
Seite 4 von 10

ELEK38010094-3.xls / Plug-Pinning
(Anschlu an Zhlwerke)
Stecker 15: 15pol Sub-D Buchsengehuse; Art.Nr: 13600092 (AMP 164532-4)
Pin
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15

colour

Farbe

red/green
rot/grn
pink/green
rosa/grn
green
grn
yellow/violet gelb/violett
blue/violet
blau/violett
brown/violet braun/violett
pink/orange
rosa/orange
green/grey
grn/grau
red/black
rot/schwarz
orange/black orange/schwarz
orange/black orange/schwarz
blue
blau
orange/red
orange/rot
yellow
gelb
yellow
gelb

qmm

Funktion

Funktion-allg.

Treiber

kurz. Bezeichnung

0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35

meter 1
meter 2
meter 3
meter 4
meter 5
meter 6
lamps on
metercount
m-security
GND
GND
meter 7
meter 8
+12VDC
+12VDC

***
***
***
***
***
***
***
***
***
***
***
***
***
***
***

***
***
***
***
***
***
***
***
***
***
***
***
***
***
***

meter 1
meter 2
meter 3
meter 4
meter 5
meter 6
lamps on
metercount
m-security
GND
GND
meter 7
meter 8
+12VDC
+12VDC

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***
***
***
***
***
***

***
***
***
***
***
***
***

GND
***
Tilt
credit output
***
+12VDC
enable

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***
***
***

***
***
***
***

Funktion-allg.

Treiber

***
***
***

***
***
***

(Anschlu an CC-46)
Stecker 16: 7pol Buchsengehuse RM2.54; Art.Nr: 13100073 (Molex 22-01-2075)
Pin

colour

Farbe

qmm

01
02
03
04
05
06
07

black
nc
orange
blue
nc
yellow
violet

schwarz
nc
orange
blau
nc
gelb
violett

0.35
***
0.35
0.35
***
0.35
0.35

Funktion
GND
***
Tilt
credit output
***
+12VDC
enable

(Anschlu an WBA-Statusanzeige)
Stecker 17: 4pol Buchsengehuse RM2.54; Art.Nr: 13100014 (Molex 22-01-2045)
Pin

colour

Farbe

qmm

01
02
03
04

yellow
pink
blue
violet

gelb
rosa
blau
violett

0.35
0.35
0.35
0.35

Funktion
+12VDC
LED A (rot)
LED B (grn)
LED C (gelb)

+12VDC
LED A (rot)
LED B (grn)
LED C (gelb)

(Anschlu an Mnzkanallichtschranke 1 [oben])


Stecker 18: 3pol Buchsengehuse RM2.54; Art.Nr: 13100066 (Molex 22-01-2035)
Pin

colour

Farbe

qmm

01
02
03

black
pink/grey
yellow

schwarz
rosa/grau
gelb

0.35
0.35
0.35

AGI
2352 Gumpoldskirchen
Wiener Strae 158

Funktion
GND
Signal A
+12VDC

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

kurz. Bezeichnung
GND
Signal A
+12VDC

Erstellt von Geischlger


nderungsstand: 03
Seite 5 von 10

ELEK38010094-3.xls / Plug-Pinning
(Anschlu an Mnzkanallichtschranke 2 [unten])
Stecker 19: 3pol Buchsengehuse RM2.54; Art.Nr: 13100066 (Molex 22-01-2035)
Pin

colour

Farbe

qmm

01
02
03

black
white/violet
yellow

schwarz
wei/violett
gelb

0.35
0.35
0.35

Funktion

Funktion-allg.

Treiber

***
***
***

***
***
***

GND
Signal B
+12VDC

kurz. Bezeichnung
GND
Signal B
+12VDC

(Anschlu an Mnzweiche)
Stecker 20: 2pol. Molex Buchsengehuse Mini-Fit; Art.Nr:13100053 (Molex 39-01-2020)
Pin

colour

Farbe

qmm

01
02

yellow
red/violet

gelb
rot/violett

0.35
0.35

Funktion

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***

***

+12VDC
CCHS1

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***
***

***
***
***

Funktion-allg.

Treiber

***
***
***
***
***

***
***
***
***
***

Funktion-allg.

Treiber

***
***
***
***

***
***
***
***

+12VDC
CCHS1

(Anschlu an Backplane, Mnzweiche)


Stecker 21: 3pol Buchsengehuse RM2.54; Art.Nr: 13100066 (Molex 22-01-2035)
Pin

colour

Farbe

qmm

01
02
03

red/violet
nc
yellow

rot/violett
nc
gelb

0.35
***
0.35

Funktion
CCHS1
nc
+12VDC

CCHS1
nc
+12VDC

(Anschlu an Backplane, Mnzkanallichtschranke [X5])


Stecker 22: 5pol Buchsengehuse RM2.54; Art.Nr: 13100058 (Molex 22-01-2055)
Pin

colour

Farbe

qmm

01
02
03
04
05

yellow
black
pink/grey
white/violet
nc

gelb
schwarz
rosa/grau
wei/violett
nc

0.35
0.35
0.35
0.35
***

Funktion
+12VDC
GND
Signal A
Signal B
nc

kurz. Bezeichnung
+12VDC
GND
Signal A
Signal B
***

(Anschlu an Backplane, WBA-Statusanzeige [X15])


Stecker 23: 4pol Buchsengehuse RM2.54; Art.Nr: 13100014 (Molex 22-01-2045)
Pin

colour

Farbe

qmm

01
02
03
04

yellow
pink
blue
violet

gelb
rosa
blau
violett

0.35
0.35
0.35
0.35

AGI
2352 Gumpoldskirchen
Wiener Strae 158

Funktion
+12VDC
LED A (rot)
LED B (grn)
LED C (gelb)

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

kurz. Bezeichnung
+12VDC
LED A (rot)
LED B (grn)
LED C (gelb)

Erstellt von Geischlger


nderungsstand: 03
Seite 6 von 10

ELEK38010094-3.xls / Plug-Pinning
(Anschlu an Backplane, CC-46 [X8])
Stecker 24: 8pol Buchsengehuse RM2.54 Art.Nr: 13100044 (Molex 22-01-2085)
Pin

colour

Farbe

qmm

01
02
03
04
05
06
07
08

orange
nc
blue
black
yellow
violet
nc
nc

orange
nc
blau
schwarz
gelb
violett
nc
nc

0.35
***
0.35
0.35
0.35
0.35
***
***

Funktion

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***
***
***
***
***
***
***

***
***
***
***
***
***
***
***

Tilt
***
credit output
GND
+12VDC
enable
***
***

Tilt
***
credit output
GND
+12VDC
enable
***
***

(Anschlu an Backplane, Zhlwerke [X9])


Stecker 25: 15pol Sub-D Stecker; Art.Nr: 13600091 (AMP: 167293-1)
Pin
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15

colour

Farbe

red/green
rot/grn
pink/green
rosa/grn
green
grn
yellow/violet gelb/violett
blue/violet
blau/violett
brown/violet braun/violett
pink/orange
rosa/orange
green/grey
grn/grau
red/black
rot/schwarz
orange/black orange/schwarz
orange/black orange/schwarz
blue
blau
orange/red
orange/rot
yellow
gelb
yellow
gelb

qmm

Funktion

Funktion-allg.

Treiber

kurz. Bezeichnung

0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35

meter 1
meter 2
meter 3
meter 4
meter 5
meter 6
lamps on
metercount
m-security
GND
GND
meter 7
meter 8
+12VDC
+12VDC

***
***
***
***
***
***
***
***
***
***
***
***
***
***
***

***
***
***
***
***
***
***
***
***
***
***
***
***
***
***

meter 1
meter 2
meter 3
meter 4
meter 5
meter 6
lamps on
metercount
m-security
GND
GND
meter 7
meter 8
+12VDC
+12VDC

Stecker 26: 2pol Mini-Fit Buchsengehuse Art.Nr: 13100053 (Molex 39-01-2020)


(Stecker fr Banknotenprfer-Trschalter)
Pin
01
02

colour

Farbe

pink
rosa
orange/black orange/schwarz

qmm

Funktion

Funktion-allg.

Treiber

kurz. Bezeichnung

0.35
0.35

S17
GND

***
***

***
***

S17
GND

Funktion

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***
***
***

***
***
***
***

GND
serielle Verbindung
serielle Verbindung
GND

(Anschlu am Backplane [X28])


Stecker 28: 4pol Tel. Modulstecker; Art.Nr: 13800031
Pin

colour

Farbe

qmm

01
02
03
04

yellow
green
brown
white

gelb
grn
braun
wei

AWG26
AWG26
AWG26
AWG26

AGI
2352 Gumpoldskirchen
Wiener Strae 158

***
***
***
***

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

Erstellt von Geischlger


nderungsstand: 03
Seite 7 von 10

ELEK38010094-3.xls / Plug-Pinning
(Anschlu am Platine P422)
Stecker 29: 4pol Tel. Modulstecker; Art.Nr: 13800031
Pin

colour

Farbe

qmm

01
02
03
04

yellow
green
brown
white

gelb
grn
braun
wei

AWG26
AWG26
AWG26
AWG26

Funktion
***
***
***
***

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***
***
***

***
***
***
***

GND
serielle Verbindung
serielle Verbindung
GND

(Anschlu an Backplane, NRI [X7])


Stecker 30: 10pol Pfostenverbinder, schneidklemm Art.Nr: 13300001 (Harting 09 18 510 7803)
Pin

colour

Farbe

qmm

Funktion

Funktion-allg.

Treiber

kurz. Bezeichnung

01
02
03
04
05
06
07
08
09
10

red
grey
grey
grey
grey
grey
grey
grey
grey
grey

rot
grau
grau
grau
grau
grau
grau
grau
grau
grau

AWG28/7
AWG28/7
AWG28/7
AWG28/7
AWG28/7
AWG28/7
AWG28/7
AWG28/7
AWG28/7
AWG28/7

Flachbandkabel RM1.27
Flachbandkabel RM1.27
Flachbandkabel RM1.27
Flachbandkabel RM1.27
Flachbandkabel RM1.27
Flachbandkabel RM1.27
Flachbandkabel RM1.27
Flachbandkabel RM1.27
Flachbandkabel RM1.27
Flachbandkabel RM1.27

GND
+12VDC
Channel 5
Channel 6
Reject
ENABLE
Channal 1
Channal 2
Channal 3
Channal 4

***
***
***
***
***
***
***
***
***
***

***
***
***
***
***
***
***
***
***
***

(Anschlu am NRI)
Stecker 31: 10pol Pfostenverbinder, schneidklemm Art.Nr: 13300001 (Harting 09 18 510 7803)
Pin

colour

Farbe

qmm

Funktion

Funktion-allg.

Treiber

kurz. Bezeichnung

01
02
03
04
05
06
07
08
09
10

red
grey
grey
grey
grey
grey
grey
grey
grey
grey

rot
grau
grau
grau
grau
grau
grau
grau
grau
grau

AWG28/7
AWG28/7
AWG28/7
AWG28/7
AWG28/7
AWG28/7
AWG28/7
AWG28/7
AWG28/7
AWG28/7

Flachbandkabel RM1.27
Flachbandkabel RM1.27
Flachbandkabel RM1.27
Flachbandkabel RM1.27
Flachbandkabel RM1.27
Flachbandkabel RM1.27
Flachbandkabel RM1.27
Flachbandkabel RM1.27
Flachbandkabel RM1.27
Flachbandkabel RM1.27

GND
+12VDC
Channel 5
Channel 6
Reject
ENABLE
Channal 1
Channal 2
Channal 3
Channal 4

***
***
***
***
***
***
***
***
***
***

***
***
***
***
***
***
***
***
***
***

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***
***
***
***
***

***
***
***
***
***
***

(Spannungsversorgung 6,5" TFT)


Stecker 32: 6pol. Mini-Fit Stiftgehuse; Art.Nr:13100056 (Molex 39-01-2061)
Pin

colour

Farbe

qmm

01
02
03
04
05
06

black
black
red
yellow
yellow
green

schwarz
schwarz
rot
gelb
gelb
grn

1.0
1.0
1.0
1.0
1.0
1.0

AGI
2352 Gumpoldskirchen
Wiener Strae 158

Funktion
GND(S)
GND(S)

+5VDC(S)
+12VDC(S)
+12VDC(S)

+24VDC(S)

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

GND(S)
GND(S)

+5VDC(S)
+12VDC(S)
+12VDC(S)

+24VDC(S)

Erstellt von Geischlger


nderungsstand: 03
Seite 8 von 10

ELEK38010094-3.xls / Plug-Pinning
(Anschlu an P422)
Stecker 33: 4pol MOLEX Buchsengehuse Mini-Fit; Art.Nr: 13100026 (Molex Nr:39-01-2040)
Pin
01
02
03
04

colour

Farbe

black
schwarz
orange/black orange/schwarz
red
rot
yellow
gelb

qmm
0.5
0.5
0.5
1.0

Funktion

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***
***
***

***
***
***
***

GND(T)
GND(S)
+5VDC(S)
+12VDC(S)

Funktion-allg.

Treiber

kurz. Bezeichnung

***

***

+12VDC

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***
***
***
***
***
***
***
***
***
***
***

***
***
***
***
***
***
***
***
***
***
***
***

+5VDC
GND
***
GND
+24VDC
***
***
GND
***
***
***
***

GND(T)
GND(S)
+5VDC(S)
+12VDC

(Anschlu fr Lichterkessel Roulette P393-1)


Stecker 34: 6.3mm Fast-On, Art.Nr: 13800004 (AMP 5-160 432-3) oder Seno Nr.
Pin

colour

Farbe

qmm

white

wei

1.0

Funktion
+12VDC

(Anschlu an Backplane, zustzliche Backplaneversorgung)


Stecker 35: 12pol MOLEX Buchsengehuse Mini-Fit; Art.Nr: 13100032 (Molex Nr:39-01-2120)
Pin

colour

Farbe

qmm

01
02
03
04
05
06
07
08
09
10
11
12

red
black
nc
black
green
nc
nc
black
nc
nc
nc
nc

rot
schwarz
nc
schwarz
grn
nc
nc
schwarz
nc
nc
nc
nc

1.0
1.0
***
1.0
1.0
***
***
1.0
***
***
***
***

Funktion
+5VDC
GND
nc
GND
+24VDC
nc
nc
GND
nc
nc
nc
nc

Stecker 37: 2pol Mini-Fit Buchsengehuse Art.Nr: 13100053 (Molex 39-01-2020)


(Stecker fr LED Controller +24V)
Pin

colour

Farbe

qmm

Funktion

Funktion-allg.

Treiber

kurz. Bezeichnung

01
02

green
black

grn
schwarz

1.0
1.0

+24VDC
GND

***
***

***
***

+24VDC
GND

Funktion-allg.

Treiber

kurz. Bezeichnung

***
***
***
***

***
***
***
***

(Anschlu an Led Streifen oben)


Stecker 38: 4pol Buchsengehuse RM2.54; Art.Nr: 13100014 (Molex 22-01-2045)
Pin

colour

Farbe

qmm

01
02
03
04

nc
nc
green
black

nc
nc
grn
schwarz

***
***
0.35
0.35

AGI
2352 Gumpoldskirchen
Wiener Strae 158

Funktion
nc
nc
+24VDC
GND

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

***
***
+24VDC
GND

Erstellt von Geischlger


nderungsstand: 03
Seite 9 von 10

ELEK38010094-3.xls / Plug-Pinning
Stecker 39: 2pol Mini-Fit Buchsengehuse Art.Nr: 13100053 (Molex 39-01-2020)
(Stecker fr Topper-Versorgung +12VDC )
Pin

colour

Farbe

qmm

Funktion

Funktion-allg.

Treiber

kurz. Bezeichnung

01
02

black
yellow

schwarz
gelb

0.5
0.5

GND
+12VDC

***
***

***
***

GND
+12VDC

Key 01 (Attendant), 2x 6,3x0,8mm Winkelflachsteckhlsen 90 gewinkelt (AGI Nr: 13650094 + 21000183)


Pin

colour

Farbe

NO brown/black braun/schwarz
C orange/black orange/schwarz

qmm

Funktion

Funktion-allg.

Treiber

kurz. Bezeichnung

0.5
0.5

Attendant Switch
GND

***
***

***
***

KEY 01
GND

Key 02 (Audit), 2x 6,3x0,8mm Winkelflachsteckhlsen 90 gewinkelt (AGI Nr: 13650094 + 21000183)


Pin

colour

Farbe

NO white/black wei/schwarz
C orange/black orange/schwarz

qmm

Funktion

Funktion-allg.

Treiber

kurz. Bezeichnung

0.5
0.5

Auditor Switch
GND

***
***

***
***

KEY 02
GND

Key 03 (Test), 2x 6,3x0,8mm Winkelflachsteckhlsen 90 gewinkelt (AGI Nr: 13650094 + 21000183)


Pin

colour

Farbe

NO white/orange wei/orange
C orange/black orange/schwarz

AGI
2352 Gumpoldskirchen
Wiener Strae 158

qmm

Funktion

Funktion-allg.

Treiber

kurz. Bezeichnung

0.5
0.5

Test Switch
GND

***
***

***
***

KEY 03
GND

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

Erstellt von Geischlger


nderungsstand: 03
Seite 10 von 10

ELEK38010094-3.xls / Plug-Description

Stecker-Verbindungsliste: Hauptkabelbaum Classic Streamline & Diplomat Streamline


CSL-622,DSL 623
Art.Nr: 38010094-3
Stecker 01: 64pol. VG-Buchsengehuse; Art.Nr: 13350032 (AMP: 925 486-1)
(Anschlu an Backplane) [X31]
Stecker 02: 4pol. MOLEX Buchsengehuse; (1-reihig) RM2,54 Art.Nr:13100014 (Molex 22-01-2045)

(Anschlu an P369 Lichtschranke Empfnger)


Stecker 03: 4pol. MINI-FIT Buchsengehuse Art.Nr: 13100026 (Molex Nr:39-01-2040)
(Anschlu an Hebeleinheit)
Stecker 04: 4pol. MOLEX Buchsengehuse; (1-reihig) RM2,54 Art.Nr:13100014 (Molex 22-01-2045)

(Anschlu an P368 Lichtschranke Sende-Diode)


Stecker 05: 6pol. Mini-Fit Buchsengehuse; Art.Nr:13100029 (Molex 39-01-2060)

(Walzenversorgung)
Stecker 06: 2pol. MOLEX Stiftgehuse; Art.Nr:13050002 (Molex 03-09-2021)

(Touchscreen)
Stecker 07: 4pol MOLEX Buchsengehuse; Art.Nr: 13100002 (Molex Nr:03-09-1040)
(Anschlu an Toplightstecker)
Stecker 08: 18pol Molex Mini-Fit Stiftgehuse; Art.Nr:13100036 (Molex 39-01-2181)
(Anschlu an Adapter NFS-Netzteil)
Stecker 09: 6pol MOLEX Buchsengehuse Mini-Fit; Art.Nr: 13100029 (Molex 39-01-2060)
(Anschlu am Modularnetzteil)
Stecker 11: 6.3mm Flachstecker
6.3mm Flachstecker: AMP 5-160 432-3 oder Seno
Steckhlsengehuse fr 6.3mm: AMP 926539-1 oder Seno
(Anschlu an Display bei Walzenmaschinen)

Art.Nr. 13800004
Art.Nr. 21000007

Stecker 12: 12pol MOLEX Buchsengehuse Mini-Fit; Art.Nr: 13100032 (Molex 39-01-2120)
(Anschlu an Backplane) [X11]
Stecker 13: 2pol MOLEX Buchsengehuse Mini-Fit; Art.Nr: 13100053 (Molex 39-01-2020)
(Optionaler Anschlu fr ST12/Pin03)
Stecker 14: 4pol MOLEX Buchsengehuse Mini-Fit; Art.Nr: 13100026 (Molex 39-01-2040)
(Anschlu an Backplane, Lautsprecher [X16])
Stecker 15: 15pol Sub-D Buchsengehuse; Art.Nr: 13600092 (AMP 164532-4)
inkl. Gehuse fr 15pol. Sub-D
Art.Nr. 13600021
(Anschlu an Zhlwerke)
Stecker 16: 7pol Buchsengehuse RM2.54 Art.Nr: 13100073 (Molex 22-01-2075)
(Anschlu an CC-46)
Stecker 17: 4pol Buchsengehuse RM2.54 Art.Nr: 13100014 (Molex 22-01-2045)
(Anschlu an WBA-Statusanzeige)

AGI
2352 Gumpoldskirchen
Wiener Strae 158

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

Erstellt von Geischlger


nderungsstand: 03
Seite 1 von 4

ELEK38010094-3.xls / Plug-Description
Stecker 18: 3pol Buchsengehuse RM2.54 Art.Nr: 13100066 (Molex 22-01-2035)
(Anschlu an Mnzkanallichtschranke 1)
Stecker 19: 3pol Buchsengehuse RM2.54 Art.Nr: 13100066 (Molex 22-01-2035)
(Anschlu an Mnzkanallichtschranke 2)
Stecker 20: 2pol MOLEX Buchsengehuse Mini-Fit; Art.Nr: 13100053 (Molex 39-01-2020)
(Anschlu an Mnzweiche)
Stecker 21: 3pol Buchsengehuse RM2.54 Art.Nr: 13100066 (Molex 22-01-2035)
(Anschlu an Backplane, Mnzweiche[X6])
Stecker 22: 5pol Buchsengehuse RM2.54 Art.Nr: 13100058 (Molex 22-01-2055)
(Anschlu an Backplane, Mnzkanallichtschranke [X5])
Stecker 23: 4pol Buchsengehuse RM2.54 Art.Nr: 13100014 (Molex 22-01-2045)
(Anschlu an Backplane, LED-WBA [X15])
Stecker 24: 8pol Buchsengehuse RM2.54 Art.Nr: 13100044 (Molex 22-01-2085)
(Anschlu an Backplane, CC-46 [X8])
Stecker 25: 15pol Sub-D Stecker Art.Nr: 13600091 (AMP: 167293-1)
inkl. Gehuse fr 15pol. Sub-D
Art.Nr. 13600021
(Anschlu an Backplane, Zhlwerke [X9])
Stecker 26: 2pol Mini-Fit Buchsengehuse Art.Nr: 13100053 (Molex 39-01-2020)
(Stecker fr Banknotenprfer-Trschalter)
Stecker 28: 4pol Tel. Modulstecker Art.Nr: 13800031
(Anschlu an Backplane [X28], fr Platine P422)
Stecker 29: 4pol Tel. Modulstecker Art.Nr: 13800031
(serieller Anschlu fr Platine P422)
Stecker 30: 10pol Pfostenverbinder, schneidklemm Art.Nr: 13300001 (Harting 09 18 510 7803)
(Anschlu an Backplane fr NRI [X7])
Stecker 31: 10pol Pfostenverbinder, schneidklemm Art.Nr: 13300001 (Harting 09 18 510 7803)
(Anschlu NRI)
Stecker 32: 6pol MOLEX Stiftgehuse Mini-Fit; Art.Nr: 13100056 (Molex 39-01-2061)
(Anschlu fr Spannungsversorgung 6,5" TFT)
Stecker 33: 4pol MOLEX Buchsengehuse Mini-Fit; Art.Nr: 13100026 (Molex 39-01-2040)
(Anschlu an P422)
Stecker 34: 6.3mm Flachstecker
6.3mm Flachstecker: AMP 5-160 432-3 oder Seno
Steckhlsengehuse fr 6.3mm: AMP 926539-1 oder Seno
(Anschlu an Lichtkreis bei Grandroulette)

Art.Nr. 13800004
Art.Nr. 21000007

Stecker 35: 12pol MOLEX Buchsengehuse Mini-Fit; Art.Nr: 13100032 (Molex 39-01-2120)
(Anschlu an Backplane) [X10] zustzliche Backplaneversorgung
Stecker 37: 2pol Mini-Fit Buchsengehuse Art.Nr: 13100053 (Molex 39-01-2020)
(Stecker fr LED-Controller +24V)

AGI
2352 Gumpoldskirchen
Wiener Strae 158

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

Erstellt von Geischlger


nderungsstand: 03
Seite 2 von 4

ELEK38010094-3.xls / Plug-Description
Stecker 38: 4pol Buchsengehuse RM2.54 Art.Nr: 13100014 (Molex 22-01-2045)
(Anschlu an LED Streifen oben + 24VDC)
Stecker 39: 2pol Mini-Fit Buchsengehuse Art.Nr: 13100053 (Molex 39-01-2020)
(Stecker fr Topper Versorgung +12V)
Key01,Key02,Key03 mit 2x6,3x0,8mm Winkelflachsteckhlsen 90 mit Gehuse (AGI Nr:13650094+21000183)
(Anschlu fr Schlsselschalter)
S01 bis S15 und S21 je 2x 2.8mm x 0.5 Flachstecker 90 gewinkelt
2.8mm Flachstecker: INARCA 0010982001
Art.Nr.13800055
(Anschlu fr Lorenzo Tasten)

H01 bis H15 und H21 je 2x 2.8mm x 0.5 Flachstecker 90 gewinkelt


2.8mm Flachstecker: INARCA 0010982001
Art.Nr.13800055
(Anschlu fr Lorenzo Lampen)
S16, S18 je 2x 4.8mm Flachstecker mit Steckhlsengehuse
4.8mm x 0,5 Flachstecker: Inarca 0010915001
Art.Nr. 13800100
Steckhlsengehuse fr 4.8mm: Art.Nr. 21000100
(Anschlu fr Trschalter DROP und Trchalter DOOR in DOOR)

LS-r, LS-l je mit 2x 4.8mm x 0.5 Flachstecker mit Steckhlsengehuse


4.8mm x 0,5 Flachstecker: Inarca 0010915001
Art.Nr. 13800100
Steckhlsengehuse fr 4.8mm: Art.Nr. 21000100
(Anschlu fr Lautsprecher)
13800093
(3x 1.0 = 3.0mm)
Kappe : 13800097 (grn)
X1 Crimp. oder Parallelverbinder
(wei) +12V ungeregelt
13800091
(6x 1.0 +1x 0.5= 6.5mm)
Kappe : 13800095 (schwarz)
X2 Crimp. oder Parallelverbinder
(gelb) +12V
13800091
(9x 1.0 + 1x 0.5 = 9.5mm)
Kappe : 13800095 (schwarz)
X3 Crimp. oder Parallelverbinder
(schwarz) GND
13800094
(3x 0.35= 1.05mm)
Kappe : 13800096 (gelb)
X4 Crimp. oder Parallelverbinder
(schwarz) GND
13800094
(3x 0.35= 1.05mm)
Kappe : 13800096 (gelb)
X5 Crimp. oder Parallelverbinder
(gelb) +12 VDC
13800092
(9x 0.5 = 4.5mm)
Kappe : 13800098 (blau)
X6 Crimp. oder Parallelverbinder
(gelb) +12 VDC
13800092
(9x 0.5 = 4.5mm)
Kappe : 13800098 (blau)
X7 Crimp. oder Parallelverbinder
(orange/schwarz) GND
13800092
(9x 0.5 = 4.5mm)
Kappe : 13800098 (blau)
X8 Crimp. oder Parallelverbinder
(orange/schwarz) GND
13800092
(9x 0.5 = 4.5mm)
Kappe : 13800098 (blau)
X9 Crimp. oder Parallelverbinder
(gelb) +12 VDC
13800093
(3x 1.0 + 1x 0.35 = 3.35mm)
Kappe : 13800097 (grn)
X10 Crimp. oder Parallelverbinder
(grn) +24V
13800094
(4x 0.5= 2.00mm)
Kappe : 13800096 (gelb)
AGI
2352 Gumpoldskirchen
Wiener Strae 158

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

Erstellt von Geischlger


nderungsstand: 03
Seite 3 von 4

ELEK38010094-3.xls / Plug-Description
X11 Crimp. oder Parallelverbinder
(orange/schwarz) GND fr SS
X12 Crimp. oder Parallelverbinder
(wei/gelb) Start Taste
X13 Crimp. oder Parallelverbinder
(orange/schwarz) GND

13800094
(4x 0.5= 2.00mm)
Kappe : 13800096 (gelb)
13800094
(4x 0.35 + 1x 0.5= 1.9mm)
Kappe : 13800096 (gelb)
13800094
(3x 0.5= 1.5mm)
Kappe : 13800096 (gelb)

X14 Crimp. oder Parallelverbinder


(orange/schwarz) GND

AGI
2352 Gumpoldskirchen
Wiener Strae 158

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

Erstellt von Geischlger


nderungsstand: 03
Seite 4 von 4

ELEK38010094-3.xls

Verlegeplan

Verlegeplan: Hauptkabelbaum Classic Streamline & Diplomat Streamline


CSL-622,DSL 623
Art.Nr: 38010094-3
Nr

Farbe

colour

mm

von

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

rot
rot
violett/braun
wei/violett
wei/orange
gelb/blau
wei/schwarz
rot/blau
braun/schwarz
grau/schwarz
rosa/blau
grau
grn/schwarz
grau/violett
rosa

red
red
violet/brown
white/violet
white/orange
yellow/blue
white/black
red/blue
brown/black
grey/black
pink/blue
grey
green/black
grey/violet
pink

0.35
0.35
0.35
0.35
0.50
0.35
0.50
0.35
0.50
0.35
0.35
0.35
0.35
0.35
0.35

ST01/Pin01a
ST01/Pin01c
ST01/Pin04a
ST01/Pin04c
ST01/Pin05a
ST01/Pin05c
ST01/Pin06a
ST01/Pin06c
ST01/Pin07a
ST01/Pin07c
ST01/Pin08a
ST01/Pin08c
ST01/Pin09a
ST01/Pin09c
ST01/Pin10a

ST04/Pin01
ST02/Pin01
S21
H21
KEY 3
H06
KEY 2
H05
KEY 1
H04
ST02/Pin02
H03
S18
H02
ST26/Pin01

17
18
18a
18b
18c
19
20
21
22
23
24
25
26
27
28
29
30
30a
30b
31
32
33
34
35
36
37
38
39
40
41

wei/blau
orange/schwarz
orange/schwarz
orange/schwarz
orange/schwarz
gelb
orange/schwarz
gelb
blau/schwarz
braun/blau
orange/braun
rosa/braun
grau/grn
gelb/violett
blau/violett
rosa/grau
wei/gelb
wei/gelb
wei/gelb
wei/rot
gelb/rot
violett/schwarz
gelb/rosa
rosa/orange
rosa/schwarz
rot/schwarz
braun/grau
grn/braun
gelb/braun
wei/grau

white/blue
orange/black
orange/black
orange/black
orange/black
yellow
orange/black
yellow
blue/black
brown/blue
orange/brown
pink/brown
grey/green
yellow/violet
blue/violet
pink/grey
white/yellow
white/yellow
white/yellow
white/red
yellow/red
violet/black
yellow/pink
pink/orange
pink/black
red/black
brown/grey
green /brown
yellow/brown
white/grey

0.35
0.5
0.5
0.5
0.5
0.5
0.35
0.5
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.5
0.35
0.5
0.35
0.5
0.35
0.35
0.35
0.35

ST01/Pin10c
ST01/Pin11a
X11
X11
X11
ST01/Pin11c
ST01/Pin12a
ST01/Pin12c
ST01/Pin13a
ST01/Pin13c
ST01/Pin14a
ST01/Pin14c
ST01/Pin15a
ST01/Pin15c
ST01/Pin16a
ST01/Pin16c
ST01/Pin17a
X12
X12
ST01/Pin17c
ST01/Pin18a
ST01/Pin18c
ST01/Pin19a
ST01/Pin19c
ST01/Pin20a
ST01/Pin20c
ST01/Pin23a
ST01/Pin24a
ST01/Pin25a
ST01/Pin25c

H01
X11
KEY 3
KEY 2
KEY 1
ST07/Pin01
ST02/Pin03
ST03/Pin04
S16
H15
S15
H14
S14
H13
S13
ST04/Pin02
X12
S12
ST03/Pin02
ST03/Pin01
S11
ST07/Pin04
S10
ST07/Pin02
S09
ST07/Pin03
S08
S07
S06
H12

AGI
Wiener Strae 158
2352 Gumpoldskirchen

bis

(NO)
(1)
(1)
(1)
(1)
(1)
(1)

(1)

(NO)
(1)
(NO)
(1)
(NO)
(1)
(NO)

(NO)

(NO)
(NO)
(NO)
(NO)
(NO)
(NO)
(1)

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

Funktion

Lnge

+5VDC (NFS)
+5VDC (NFS)
RESERVE
RESERVE
Schlsselschalter 3 (Test)
PLAY 7 LINES
Schlsselschalter 2 (Audit)
PLAY 5 LINES
Schlsselschalter 1 (Attendant)
BET 2 PER LINE
doorswitch (receiver)
PLAY 3 LINES
doorswitch (door in door)
BET 1 PER LINE
doorswitch (BNP)

1510
1070
1320
1320
1750
1240
1780
1190
1810
1120
1070
1220
1070
1090
1270

PLAY 1 LINE
GND
GND
GND
GND
+12VDC
GND
+12VDC
doorswitch (drop)
SERVICE
SERVICE
COLLECT
COLLECT
PLAY 9 LINES
PLAY 9 LINES
doorswitch (transmitter)
START
START
START
enable lever
TAKE WIN
toplight (reserve)
GAMBLE
toplight (blue)
BET 10 PER LINE
toplight (white)
BET 5 PER LINE
BET 3 PER LINE
PLAY 7 LINES
AUTO START

1090
1340
510
540
570
2290
1070
1010
1425
1170
1170
1120
1120
1370
1370
1510
300
1190
810
1010
1470
2290
1390
2290
1390
2290
1340
1290
1240
1390

Erstellt von Geischlger


nderungsstand: 03
Seite 1 von 4

ELEK38010094-3.xls

Verlegeplan
42
43
44
45
46
47
48
49
50
51
52
52a
52b
53
53a
53b
53c
53d

rot/braun
rot/grau
gelb/schwarz
orange/violett
rot/violett
wei/braun
gelb/grau
blau/grau
rosa/violett
blau/grn
orange/schwarz
orange/schwarz
orange/schwarz
orange/schwarz
orange/schwarz
orange/schwarz
schwarz
schwarz

red/brown
red/grey
yellow/black
orange/violet
red/violet
white/brown
yellow/grey
blue/grey
pink/violet
blue/green
orange/black
orange/black
orange/black
orange/black
orange/black
orange/black

55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90

black
black

0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.5
0.5
0.5
0.35
0.35
0.35
0.35
0.5

ST01/Pin26a
ST01/Pin26c
ST01/Pin27a
ST01/Pin27c
ST01/Pin28a
ST01/Pin28c
ST01/Pin29a
ST01/Pin29c
ST01/Pin30a
ST01/Pin30c
ST01/Pin22a
X14
X14
ST01/Pin21a
X13
X13
X13
X13

S05
H11
S04
H10
S03
H09
S02
H08
S01
H07
X14
S16
S18
X13
ST26/Pin02
ST03/Pin03
ST38/Pin04
ST39/Pin01

orange/schwarz
orange/schwarz
orange/schwarz
orange/schwarz
orange/schwarz
orange/schwarz
orange/schwarz
orange/schwarz
orange/schwarz

orange/black
orange/black
orange/black
orange/black
orange/black
orange/black
orange/black
orange/black
orange/black

0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5

ST01/Pin31a
X7
X7
X7
X7
X7
X7
X7
X7

X7
S07
S21
S08
S13
S09
S10
S11
S12

gelb
gelb
gelb
gelb
gelb
gelb
gelb
gelb
gelb
orange/schwarz
orange/schwarz
orange/schwarz
orange/schwarz
orange/schwarz
orange/schwarz
orange/schwarz
orange/schwarz
orange/schwarz
gelb
gelb
gelb
gelb
gelb
gelb
gelb
gelb
gelb

yellow
yellow
yellow
yellow
yellow
yellow
yellow
yellow
yellow

0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5

ST01/Pin31c
X6
X6
X6
X6
X6
X6
X6
X6
ST01/Pin32a
X8
X8
X8
X8
X8
X8
X8
X8
ST01/Pin32c
X9
X9
X9
X9
X9
X9
X9
X9

X6
H07
H21
H08
H13
H09
H10
H11
H12
X8
S01
S02
S03
S04
S05
S06
S14
S15
X9
H01
H02
H03
H04
H05
H06
H14
H15

orange/black
orange/black
orange/black
orange/black
orange/black
orange/black
orange/black
orange/black
orange/black

yellow
yellow
yellow
yellow
yellow
yellow
yellow
yellow
yellow

AGI
Wiener Strae 158
2352 Gumpoldskirchen

(NO)
(1)
(NO)
(1)
(NO)
(1)
(NO)
(1)
(NO)
(1)

(C)
(C)
(C)
(C)
(C)
(C)
(C)
(C)

(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(C)
(C)
(C)
(C)
(C)
(C)
(C)
(C)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

PLAY 5 LINES
TAKE WIN
BET 2 PER LINE
GAMBLE
PLAY 3 LINES
BET 10 PER LINE
BET 1 PER LINE
BET 5 PER LINE
PLAY 1 LINE
BET 3 PER LINE
GND
GND
GND
GND
GND
GND
GND
GND

1190
1470
1120
1390
1220
1390
1090
1340
1090
1290
340
1265
830
840
530
270
1650
1600

GND
GND
GND
GND
GND
GND
GND
GND
GND

1270
220
250
170
200
220
220
300
220

+12VDC
+12VDC
+12VDC
+12VDC
+12VDC
+12VDC
+12VDC
+12VDC
+12VDC
GND
GND
GND
GND
GND
GND
GND
GND
GND
+12VDC
+12VDC
+12VDC
+12VDC
+12VDC
+12VDC
+12VDC
+12VDC
+12VDC

1320
270
300
220
250
170
170
250
170
1120
270
270
200
300
170
220
300
250
1020
170
170
300
200
270
320
200
250

Erstellt von Geischlger


nderungsstand: 03
Seite 2 von 4

Verlegeplan
91
schwarz
92
schwarz
93
schwarz
94
schwarz
95
schwarz
96
schwarz
97 orange/schwarz
98
schwarz
98a
schwarz
98b
schwarz
99
gelb
100
gelb
101
gelb
102
gelb
103
gelb
103a
gelb
103b
gelb
104
rot
105
rot
106
rot
107
schwarz
108
gelb
109
gelb
110
grn
111
grn
112
grn
112a
grn
113
schwarz
114
schwarz
115
violett
116
orange
117
grn
118
wei
119
wei
120
wei
121
wei
122
wei
123
schwarz
124
schwarz
125
126
127
128

rot/schwarz
orange/schwarz
orange/grn
orange/schwarz

black
black
black
black
black
black

ELEK38010094-3.xls

black
black
black
yellow
yellow
yellow
yellow
yellow
yellow
yellow
red
red
red
black
yellow
yellow
green
green
green
green
black
black
violet
orange
green
white
white
white
white
white
black
black

1.0
1.0
1.0
1.0
1.0
1.0
0.5
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
0.5
1.0
1.0
0.5
1.0
1.0
1.0
1.0
1.0
1.0
0.35
1.0
1.0
1.0
0.5
1.0
1.0
1.0
1.0
1.0
1.0
0.5
1.0

ST08/Pin05
X3
X3
X3
X3
X3
X3
X3
X3
X3
ST08/Pin07
X2
X2
X2
X2
X2
X2
ST08/Pin01
ST08/Pin02
ST08/Pin03
ST08/Pin04
ST08/Pin06
ST08/Pin08
ST08/Pin09
X10
X10
X10
ST08/Pin12
ST08/Pin13
ST08/Pin14
ST08/Pin17
ST08/Pin18
ST09/Pin01
ST09/Pin02
X1
X1
ST09/Pin03
ST09/Pin06
ST09/Pin05

X3
ST32/Pin01
ST32/Pin02
ST05/Pin02
ST12/Pin04
ST06/Pin01
ST33/Pin02
ST05/Pin04
ST35/Pin04
ST35/Pin02
X2
ST05/Pin03
ST32/Pin04
ST32/Pin05
ST06/Pin02
ST33/Pin04
ST39/Pin02
ST12/Pin01
ST32/Pin03
ST33/Pin03
ST09/Pin04
ST13/Pin01
ST12/Pin09
X10
ST05/Pin01
ST32/Pin06
ST38/Pin03
ST12/Pin02
ST12/Pin06
ST12/Pin12
ST12/Pin11
ST12/Pin05
ST12/Pin03
X1
ST05/Pin05
ST34
ST11
ST33/Pin01
ST05/Pin06

GND (NFS)
GND (NFS)
GND (NFS)
GND (NFS)
GND (NFS)
GND (NFS)
GND (NFS)
GND (NFS)
GND (NFS)
GND (NFS)
+12VDC (NFS)
+12VDC (NFS)
+12VDC (NFS)
+12VDC (NFS)
+12VDC (NFS)
+12VDC (NFS)
+12VDC (NFS)
+5VDC (NFS)
+5VDC (NFS)
+5VDC (NFS)
GND (NFS)
+12VDC (NFS)
+12VDC (NFS)
+24VDC (NFS)
+24VDC (NFS)
+24VDC (NFS)
+24VDC (NFS)
GND (NFS)
GND (NFS)
-12VDC (NFS)
PFD
+24VDC (NFS)
+12VDC (Trafo)
+12VDC (Trafo)
+12VDC (Trafo)
+12VDC (Trafo)
+12VDC (Trafo)
GND (Trafo)
GND (Trafo)

200
990
990
920
500
880
940
920
530
530
300
820
1090
1090
780
1040
1580
600
1090
1040
1380
620
600
430
690
1220
1500
600
600
600
600
600
1680
150
1190
1850
2610
2120
1240

red/black
orange/black
orange/green
orange/black

0.35
0.35
0.35
0.35

ST14/Pin01
ST14/Pin02
ST14/Pin03
ST14/Pin04

LS-r
LS-r
LS-l
LS-l

audio rechts
audio-GND
audio links
audio-GND

1340
1340
940
940

orange/black

AGI
Wiener Strae 158
2352 Gumpoldskirchen

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

Erstellt von Geischlger


nderungsstand: 03
Seite 3 von 4

Verlegeplan

ELEK38010094-3.xls

129
130
131
132
133
134
135
136
137
138
139
140
141
142
143

rot/grn
rosa/grn
grn
gelb/violett
blau/violett
braun/violett
rosa/orange
grn/grau
rot/schwarz
orange/schwarz
orange/schwarz
blau
orange/rot
gelb
gelb

red/green
pink/green
green
yellow/violet
blue/violet
brown/violet
pink/orange
green/grey
red/black
orange/black
orange/black
blue
orange/red
yellow
yellow

0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35

ST15/Pin01
ST15/Pin02
ST15/Pin03
ST15/Pin04
ST15/Pin05
ST15/Pin06
ST15/Pin07
ST15/Pin08
ST15/Pin09
ST15/Pin10
ST15/Pin11
ST15/Pin12
ST15/Pin13
ST15/Pin14
ST15/Pin15

ST25/Pin01
ST25/Pin02
ST25/Pin03
ST25/Pin04
ST25/Pin05
ST25/Pin06
ST25/Pin07
ST25/Pin08
ST25/Pin09
ST25/Pin10
ST25/Pin11
ST25/Pin12
ST25/Pin13
ST25/Pin14
ST25/Pin15

meter 1
meter 2
meter 3
meter 4
meter 5
meter 6
lamps on
metercount
m-security
GND
GND
meter 7
meter 8
+12VDC
+12VDC

1145
1145
1145
1145
1145
1145
1145
1145
1145
1145
1145
1145
1145
1145
1145

144
145
146
147
148

schwarz
orange
blau
gelb
violett

black

orange
blue
yellow
violet

0.35
0.35
0.35
0.35
0.35

ST16/Pin01
ST16/Pin03
ST16/Pin04
ST16/Pin06
ST16/Pin07

ST24/Pin04
ST24/Pin01
ST24/Pin03
ST24/Pin05
ST24/Pin06

GND
Tilt
credit output
+12VDC
enable

1435
1435
1435
1435
1435

149
150
151
152

gelb
rosa
blau
violett

yellow
pink
blue
violet

0.35
0.35
0.35
0.35

ST17/Pin01
ST17/Pin02
ST17/Pin03
ST17/Pin04

ST23/Pin01
ST23/Pin02
ST23/Pin03
ST23/Pin04

+12VDC
LED A (rot)
LED B (grn)
LED C (gelb)

1455
1455
1455
1455

153
154
155
156
157
158
159
160

gelb
gelb
gelb
schwarz
schwarz
schwarz
rosa/grau
wei/violett

yellow
yellow
yellow
black
black
black
pink/grey
white/violet

0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35

ST22/Pin01
X5
X5
ST22/Pin02
X4
X4
ST22/Pin03
ST22/Pin04

X5
ST18/Pin03
ST19/Pin03
X4
ST18/Pin01
ST19/Pin01
ST18/Pin02
ST19/Pin02

+12VDC
+12VDC
+12VDC
GND
GND
GND
Signal A
Signal B

1475
290
220
1425
240
270
1565
1595

161
162

rot/violett
gelb

red/violet
yellow

0.35
0.35

ST21/Pin01
ST21/Pin03

ST20/Pin02
ST20/Pin01

CCHS1
+12VDC

1295
1295

163

4xAWG26

ST28

ST29

serielle Verbindung

990

164

AWG 28/7

ST-30

ST31

Flachbandkabel

1355

165
166

rot
rot

red
red

1.0
1.0

ST08/Pin10
ST08/Pin11

ST35/Pin01
ST12/Pin07

+5VDC
+5VDC

630
600

167
168

grn
schwarz

green
black

1.0
1.0

ST35/Pin05
ST35/Pin08

ST37/Pin01
ST37/Pin02

+24VDC
GND

870
870

AGI
Wiener Strae 158
2352 Gumpoldskirchen

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

Erstellt von Geischlger


nderungsstand: 03
Seite 4 von 4

ELEK38010094-3.xls/Ergnzung
Folgende Kontakte werden im Hauptkabelbaum 38010094-3 verwendet.
AGI Art.Nr.

Bezeichnung

Molex Nr.

Verwendung

Anzahl

13650061

Buchsenkontakt crimp. fr VG-Federleiste

AMP: 166500-2

ST01

56

alle belegten Pins

13650002

Stiftkontakt crimp. 1190TL geg. AWG 14-20

02-09-2101

ST-06
Gesamt

2
2

Pin 01,02

13650008

Buchsenkontakt crimpb. Molex 1189TL gegurtet

02-09-1102

ST-07
Gesamt

4
4

Pin 01,02,03,04

13650074

Stiftkontakt crimp. 5558T geg. AWG 16 Phosphor Bronze

39-00-0083

ST-08
ST-32
Gesamt

14
6
20

Pin 01,02, 04-09,10,11,12-14,18


Pin 01-06

13650075

Stiftkontakt crimp. Molex 5558 geg. AWG 18-24 Phosphor Br.

39-00-0061

ST-08
Gesamt

2
2

Pin 03,17

13650072

Buchsenkontakt crimpb. Molex 5556 T geg. AWG 16 Phosphor Br.

39-00-0079

ST-05
ST-13
ST-12
ST-09
ST-33
ST-35
ST-37
Gesamt

6
1
9
5
1
5
2
29

Pin 01-06
Pin 01
Pin 01-06,07,09,12
Pin 01-05
Pin 04
Pin 01,02,04,05,08
Pin 01,02

13650073

Buchsenkontakt crimpb. Molex 5556 T geg. AWG 18-24 Phosphor Br.

39-00-0059

ST-03
ST-09
ST-12
ST-14
ST-26
ST-33
ST-20
ST-39
Gesamt

4
1
1
4
2
3
2
2
19

Pin 01-04
Pin 06
Pin 11
Pin 01-04
Pin 01,02
Pin 01,02,03
Pin 01,02
Pin 01,02

AGI
2352 Gumpoldskirchen
Wiener Strae 158

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

Pin

Erstellt von Geischlger


nderungsstand: 03
Seite 1 von 4

ELEK38010094-3.xls/Ergnzung
13650013

Buchsenkontakt crimp. 40445-T Geg. AWG 22-30

97-00-0444

ST-02
ST-04
ST-16
ST-17
ST-18
ST-19
ST-21
ST-22
ST-23
ST-24
ST-38
Gesamt

3
2
5
4
3
3
2
4
4
5
2
37

Pin 01-03
Pin 01,02
Pin 01,03,04,06,07
Pin 01-04
Pin 01-03
Pin 01-03
Pin 01,03
Pin 01-04
Pin 01-04
Pin 01,03-06
Pin 03,04

13650067

Buchsenkontakt crimp. fr Sub-D

AMP: 166051-1

ST15

15

Pin: 01 - 15

13650068

Stiftkontakt crimp. fr Sub-D

AMP: 166053-1

ST25

15

Pin: 01 - 15

13800004

Flachsteckhlse 6.3 x 0.8mm crimpbar

Seno 0010129001

ST11
ST34
Gesamt

1
1
2

13800100

Flachsteckhlse 4.8 x 0.5mm crimpbar (Querschnitt 0.3 - 1.0)


Material CU ZN

Seno 0010915001

S16
S18
LS-L
LS-R
Gesamt

2
2
2
2
8

AGI
2352 Gumpoldskirchen
Wiener Strae 158

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

Pin: No; C
Pin: No; C
Pin: +; Pin: +; -

Erstellt von Geischlger


nderungsstand: 03
Seite 2 von 4

ELEK38010094-3.xls/Ergnzung
13800055

13650094

Flachsteckhlse INARCA 2,8mm x 0,5 90 gewinkelt

6,3x0,8mm Winkelflachsteckhlse 90, crimpb, geg., 0,50-1,50mm

AGI
2352 Gumpoldskirchen
Wiener Strae 158

Seno 0010982001

Tyco 1-280050-2

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

S01
S02
S03
S04
S05
S06
S07
S08
S09
S10
S11
S12
S13
S14
S15
S21

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Pin: NO; C
Pin: NO; C
Pin: NO; C
Pin: NO; C
Pin: NO; C
Pin: NO; C
Pin: NO; C
Pin: NO; C
Pin: NO; C
Pin: NO; C
Pin: NO; C
Pin: NO; C
Pin: NO; C
Pin: NO; C
Pin: NO; C
Pin: NO; C

H01
H02
H03
H04
H05
H06
H07
H08
H09
H10
H11
H12
H13
H14
H15
H21
Gesamt

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
64

Pin: 01; 02
Pin: 01; 02
Pin: 01; 02
Pin: 01; 02
Pin: 01; 02
Pin: 01; 02
Pin: 01; 02
Pin: 01; 02
Pin: 01; 02
Pin: 01; 02
Pin: 01; 02
Pin: 01; 02
Pin: 01; 02
Pin: 01; 02
Pin: 01; 02
Pin: 01; 02

Key 01
Key 02
Key 03
Gesamt

2
2
2
6

Pin: C; NO
Pin: C; NO
Pin: C; NO

Erstellt von Geischlger


nderungsstand: 03
Seite 3 von 4

ELEK38010094-3.xls/Ergnzung
21000183

Gehuse fr 6,3x0,8mm Winkelflachsteckhlsen 90

AGI
2352 Gumpoldskirchen
Wiener Strae 158

Tyco 0-180 984-0

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

Key 01
Key 02
Key 03
Gesamt

2
2
2
6

Pin: C; NO
Pin: C; NO
Pin: C; NO

Erstellt von Geischlger


nderungsstand: 03
Seite 4 von 4

ELEK38010094-3.xls/nderungen _Changes

beim KB 38010094-3 wurde gegenber 38010094-2 folgendes gendert:


(Changes 38010094-3 to 38010094-2)
Schlsselschalter mit gewinkelter 6.3mm Flachsteckhlse ausgefhrt, Querschnitt auf 0.5 qmm erhht
(KEYS with right-angled 6,3mm Fast On Connectors, wire cross section 0.5 qmm)

beim KB 38010094-2 wurde gegenber 38010094-1 folgendes gendert:


ST01: zustzlich 100mmm Certobandumwickelung
ST03: Doppelanschlag entfernt, dafr X12 dazu
ST05: Verlngerung um 34cm + Certobandumwickelung
ST08: Pin 10 und Pin11 dazu (rot +5V) (Leitung 165 und 166)
ST12: Pin07 dazu (rot +5V) (Leitung 168)
ST18 und ST19: 20mm lnger, damit kein Problem beim durchfdeln entsteht
Crimpverbinder X4 und X5 mssen nach rckwrts gebunden werden
Certoband dazu
ST27 und S17 entfernt (Leitung 16 und 54 entfernt)
ST31: FBK um 30mm verlngert
ST33 Pin 4 gelbe Leitung +12V dazu von X2 (1.0) (Leitung 103a)
ST35 neu dazu
ST37 neu dazu (+24V Versorgung fr LED Controller im Trbereich) (Leitungen 167 u. 168)
ST38 neu dazu (Versorgung fr Led Leiste oben +24V)
ST39 neu dazu (Versorgung fr Topper +12V) (gelb 103b und schwarz 53d)
S18 um 80mm verlngert
X11 neu dazu (orange/schwarz 18,18a,18b,18c)
X12 neu dazu (3x ws/ge Leitungen 30,30a,30b)
X13 neu dazu (orange/schwarz 53,53a,53b, schwarz 53c,53d)
X14 neu dazu (orange/schwarz 52,52a,52b)
X2 (gelb 1.0 und 0.5 dazu) ( Leitung: 103a und 103b)
X10 grn 0.35 dazu fr ST38 (Leitung 112a)
X3 schwarz 2x 1.0 dazu (Leitung 98a und 98b)

AGI
2352 Gumpoldskirchen
Wiener Strae 158

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

Erstellt von Geischlger


nderungsstand: 03
Seite 1 von 2

ELEK38010094-3.xls/nderungen _Changes

English:
ST01: additional 100mmm Certotape
ST03: no doublecrimp, X12 additionaly
ST05: extra length 34cm + Certotape
ST08: Pin 10 and Pin11 additionaly (red +5V) (line 165 and 166)
ST12: Pin07 additionaly (red +5V) (line 168)
ST18 and ST19: 20mm longer
Crimpconnector X4 and X5 must be fixed backwards using cable tie
Certotape additionaly
ST27 and S17 canceld (line 16 und 54 canceld)
ST31: FBK 30mm longer
ST33 Pin 4 yellow line +12V additionaly from X2 (1.0) (line 103a)
ST35 new
ST37 new (line 167 and 168)
ST38 new (supply for Led +24V)
ST39 new (supply for Topper +12V) (yellow 103b and black 53d)
S18: 80mm longer
X11 new (orange/black 18,18a,18b,18c)
X12 new (3x wht/yel line 30,30a,30b)
X13 new (orange/black 53,53a,53b, black 53c,53d)
X14 new (orange/black 52,52a,52b)
X2 (yellow 1.0 and 0.5 new) ( line: 103a and 103b)
X10 green 0.35 new for ST38 (line 112a)
X3 black 2x 1.0 new (line 98a and 98b)

AGI
2352 Gumpoldskirchen
Wiener Strae 158

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

Erstellt von Geischlger


nderungsstand: 03
Seite 2 von 2

ELEK38010094-3.xls/Backplanepinning

Pinbelegung der 64pol. VG-Federleiste (NGC-BOARD Backplane)


Pinnbelegung BACKPLANE
(64pol. VG-Messerleiste)
Pin Nr: Hardware-Funktion
1a
1c
2a
2c
3a
3c
4a
4c
5a
5c
6a
6c
7a
7c
8a
8c
9a
9c
10a
10c
11a
11c
12a
12c
13a
13c
14a
14c
15a
15c
16a
16c
17a
17c
18a
18c
19a
19c
20a
20c
21a
21c
22a
22c
23a
23c

GND
+12VDC
GND
+12VDC
INPUT 5
OUTPUT 1
INPUT 6
OUTPUT 2
INPUT 7
OUTPUT 3
INPUT 8
OUTPUT 4
INPUT 9
OUTPUT 5
INPUT 10
OUTPUT 6
INPUT 11
OUTPUT 7
INPUT 12
OUTPUT 8
GND
+12VDC
GND
+12VDC
INPUT 13
OUTPUT 9
INPUT 14
OUTPUT 10
INPUT 15
OUTPUT 11
INPUT 16
OUTPUT 12
INPUT 17
OUTPUT 13
INPUT 18
OUTPUT 14
INPUT 19
OUTPUT 15
INPUT 20
OUTPUT 16
GND
+12VDC
GND
+12VDC
INPUT 21
OUTPUT 17

AGI
2352 Gumpoldskirchen
Wiener Strae 158

Pinnbelegung Kabelbaum
(64pol. VG-Federleiste)
Treiber

Pin Nr:
32a
31a
30a

ULN2803
29a
ULN2803
28a
ULN2803
27a
ULN2803
26a
ULN2803
25a
ULN2803
24a
ULN2803
23a
ULN2803
22a
21a
20a
ULN2803
19a
ULN2803
18a
ULN2803
17a
ULN2803
16a
ULN2803
15a
ULN2803
14a
ULN2803
13a
ULN2803

Funktion

GND
32c +12VDC
GND
31c +12VDC
Taste 1
30c Lampe 7
Taste 2
29c Lampe 8
Taste 3
28c Lampe 9
Taste 4
27c Lampe 10
Taste 5
26c Lampe 11
Taste 6
25c Lampe 12
Taste 7
24c nc
Taste 8
23c nc
GND
22c +12VDC
GND
21c +12VDC
Taste 9
20c toplight (wei) 1
Taste 10
19c toplight (blau) 2
Taste 11
18c toplight (reserve) 3
Taste 12
17c Freigabe Hebel
Taste 13
16c Trschalter-optisch (transmitter-doorswitch)
Taste 14
15c Lampe 13
Taste 15
14c Lampe 14
Trschalter DROP

13c Lampe 15
GND
12c +12VDC
11a
GND
11c +12VDC
Trschalter BNP
10a
10c Lampe 1
12a

ULN2064

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

Bezeichnung

k. Bezeichnug

GND
+12VDC
GND
+12VDC
S01
H07
S02
H08
S03
H09
S04
H10
S05
H11
S06
H12
S07
***
S08
***
GND
+12VDC
GND
+12VDC
S09
H18
S10
H19
S11
H20
S12
***
S13
***
S14
H13
S15
H14
S16
H15
GND
+12VDC
GND
+12VDC
S17
H01

GND
+12VDC
GND
+12VDC
PLAY 1 LINE
BET 3 PER LINE
BET 1 PER LINE
BET 5 PER LINE
PLAY 3 LINES
BET 10 PER LINE
BET 2 PER LINE
GAMBLE
PLAY 5 LINES
TAKE WIN
PLAY 7 LINES
AUTO START
BET 3 PER LINE

***
BET 5 PER LINE

***
GND
+12VDC
GND
+12VDC
BET 10 PER LINE
TOPLIGHT (white)
GAMBLE
TOPLIGHT (blue)
TAKE WIN
TOPLIGHT (reserve)
AUTO START
enable lever

PLAY 9 LINES
doorswitch (transmitter)

COLLECT
PLAY 9 LINES
SERVICE

COLLECT
doorswitch-drop

SERVICE
GND
+12VDC
GND
+12VDC
doorswitch-BNP
PLAY 1 LINE

Erstellt von Geischlger


nderungsstand: 03
Seite 1 von 2

ELEK38010094-3.xls/Backplanepinning

24a

INPUT 22
24c

25a

9a
OUTPUT 18 ULN2064

INPUT 23
25c

26a

8a
OUTPUT 19 ULN2064

INPUT 24
26c

27a

7a

INPUT 25

28a

6a

INPUT 26

29a

5a

INPUT 27

30a

4a
OUTPUT 23 ULN2064

INPUT 28
30c

31a
31c
32a
32c

3a

OUTPUT 24 ULN2064
VCC +5VDC
VCC +5VDC
VCC +5VDC
VCC +5VDC

AGI
2352 Gumpoldskirchen
Wiener Strae 158

Schlsselschalter 2

6c Lampe 5

OUTPUT 22 ULN2064

29c

Schlsselschalter 1

7c Lampe 4

OUTPUT 21 ULN2064

28c

Trschalter-optisch (receiver doorswitch)

8c Lampe 3

OUTPUT 20 ULN2064

27c

Trschalter (Tre in Tre)

9c Lampe 2

2a
1a

Schlsselschalter 3

5c Lampe 6
Schalter 21
4c Lampe 21
nc
3c nc
VCC +5VDC
2c VCC +5VDC
VCC +5VDC
1c VCC +5VDC

HAUPTKABELBAUM Classic Streamline


Art.Nr:38010094-3
Datum: 19.07.2007

S18
H02
?
H03
KEY1
H04
KEY2
H05
KEY3
H06
S21
H21
S22
H22
VCC +5VDC
VCC +5VDC
VCC +5VDC
VCC +5VDC

doorswitch (door in door)


BET 1 PER LINE
doorswitch (receiver)
PLAY 3 LINES
attendant-?
BET 2 PER LINE
audit-?
PLAY 5 LINES
test-?
PLAY 7 LINES
RESERVE
RESERVE
***

***
VCC +5VDC
VCC +5VDC
VCC +5VDC
VCC +5VDC

Erstellt von Geischlger


nderungsstand: 03
Seite 2 von 2

Potrebbero piacerti anche