Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
BUSSMANN
SERIES
The protection
SERIESS
Eaton offers more possibilities
and powerful solutions to
meet your needs.
1007July 2015
Eaton.com/bussmannseries
iii
Quik-Spec
Coordination Panels
iv
Power Module
Panel
Power Module
Switch
CUBEFuse
Safety Switches
Circuit
Protection
1007July 2015
Surge Protective
Devices
Eaton.com/bussmannseries
Quik-Spec Coordination
Panels (QSCP)
Power Module
Panel
CUBEFuse
Safety Switches
Power Module
Switch
Circuit
Protection
Surge Protective
Devices
1007July 2015
Eaton.com/bussmannseries
Circuit
Protection
vi
Surge Protective
Devices
Disconnects
Safety
Switches
Fuse Holders
and Blocks
Power
Distribution
Fuse Block
1007July 2015
Panel-Mount
Fuse Holders
Eaton.com/bussmannseries
Power
Distribution
Blocks
DIN-Rail
Terminal
Blocks
A
E
A
B
D
B
Chiller
C
Parallel
refrigeration rack
Cooling tower D
Condenser/
fluid cooler
Chiller/parallel
refrigeration rack
Cooling tower
Condenser/fluid
cooler
1007July 2015
Eaton.com/bussmannseries
vii
Photovoltaic
Fuses
viii
DC/Solar
Circuit Breakers
Solar String
Protectors
Modular
Fuse Holders
Photovoltaic
SPDs
UL and IEC
SPDs
1007July 2015
AC/DC
Safety
Switches
Eaton.com/bussmannseries
High Speed
Fuses
AC Fuses
AC
Circuit
Breakers
C
D
C
B
10
2
1
1
3
7
1
4
7
3
5
Wire harness
Combiner box
Re-combiner box
Inverter
Photovoltaic fuses
AC/DC switches
AC fuses
Combiner box
Re-combiner box
Inverter
10 AC breakers
1007July 2015
Eaton.com/bussmannseries
ix
Selective coordination
Eaton offers the broadest circuit protection and electrical safety solutions in the industry that enable customers to achieve
code compliance more effectively and economically than our competitors. Whats more, we offer technical expertise and a
support structure to help achieve project goals, whether facing new construction, expansion or renovation.
Circuit protection
1007July 2015
Eaton.com/bussmannseries
Accessories
Accessories
Services and
application guide
Services and
application guide
Surge protective
devices
Telecom protection
products
Medium voltage
fuses
New
product
New
product
Connectors
New
product
Power distribution
& terminal blocks
Index by
part number
Fuse holders
and blocks
Low voltage
branch circuit
Solar
products
Low voltage
supplementary
Electronic
fuses
Disconnects
New
product
High speed
fuses
New
product
Surge protective
devices
High speed
fuses
New
product
Telecom protection
products
Quik-Spec
electrical gear
xi
Eaton.com/bussmannseries
1007July 2015
Index by
part number
Disconnects
Electronic
fuses
Connectors
Low voltage
supplementary
Power distribution
& terminal blocks
Solar
products
Fuse holders
and blocks
Low voltage
branch circuit
Quik-Spec
electrical gear
Table of contents
Red indicates new information
Vertical market product pages . . . . . . . . . . . . . .iv
Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iv
HVAC/C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .vi
Solar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viii
Electrical safety and reliability . . . . . . . . . . . . . . . . . . . . . . .x
Eaton circuit protection solutions comply with major industrial standards and agency requirements such as: BS, IEC, DIN, UL, NEMA, CSA, CE, C-UL, etc. and are manufactured at facilities that are ISO 9000 certified.
This catalog is intended to present product data and provide technical information that will help the end user with design application. Eaton reserves the right, without notice, to change design or construction or any products and
to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this catalog. Once a product has been selected, it should be tested by the
user in all possible applications. Further, Eaton takes no responsibility for errors or omissions contained in this catalog, or for mis-application of any Eaton product. Extensive product information is available in the Eaton product
2015 Eaton
data sheets available on line at www.cooperbussmann.com/DatasheetsEle.
xii
1007July 2015
Eaton.com/bussmannseries
Table of contents
Red indicates new information
Section 6 - High speed semiconductor
fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-1
General applications . . . . . . . . . . . . . . . . . . . . . . . . . .6-2
North American fuses and accessories
DFJ, FWA, FWH, FWJ, FWP, FWX, KAC, KBC, . . .6-4
Square body fuses and accessories
DIN 43 620, DIN 43 653, flush-end contact,
French Style, US Style 170E, 170F, 170H, 170M .6-22
British BS 88 fuses and accessories
CT, ET, EET, FE, FEE, FM, FMM, LCT, LET,
LMMT, LMT, MMT, MT . . . . . . . . . . . . . . . . . . . . .6-94
Ferrule fuses and accessories
FWA, FWC, FWH, FWJ, FWK, FWL, FWP,
FWS, FWX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-103
1007July 2015
Eaton.com/bussmannseries
xiii
Intro
Table of contents
Red indicates new information
Non-Fused UL 98
30 to 1200A enclosed disconnects . . . . . . . . . . . . . . . .12-43
Non-Fused UL 508
16 to 80A enclosed disconnects . . . . . . . . . . . . . . . . 12-45
Fused, dead front disconnect switches . . . . . . . . . . 12-47
xiv
1007July 2015
Eaton.com/bussmannseries
Table of contents
Intro
Catalog sections
Page
dimension fuses..........................................4-1
electrical gear........................8-1
1007July 2015
Eaton.com/bussmannseries
xv
Ballasts
Indoor
Fluorescent
Holder(s)
HLR
Fuse
GLQ
GMQ
Holder(s)
HLQ
Holder(s)
HPF
HPS
Fuse
KTK-R
FNQ-R
LP-CC
Holder(s)
HPS-RR
HPF-RR
KTQ
BBS
HPS-L
HPF-L
Fuse
SC 0-15
Holder(s)
HPF-EE
HPS-EE
SC 20
HPF-JJ
HPS-JJ
SC 25-30 HPF-FF
HPS-FF
Fuse
BAF
KTK
FNM
FNQ
Holder(s)
HEB
HEX
HPC-D
Fuse
KTK-R
FNQ-R
LP-CC
Holder(s)
HEY
Protected by
non-time-delay fuses.
xvi
Fuse recommendations
Volts
0-250
0-600
1007July 2015
Eaton.com/bussmannseries
Fuse(s)
LPN-RK_SP, FRN-R
LPS-RK_SP, FRS-R
LPJ_SP, LP-CC,
FNQ-R, TCF
Fuse recommendations
Volts
0-250
0-300
0-600
Fuse(s)
KTN-R
JJN
KTS-R
JKS, KTK-R
JJS, FCF_RN
Fuse recommendation
Volts
0-250
0-300
0-480
0-600
0-600
0-600
Fuse(s)
LPN-RK_SP
FRN-R, NON
JJN
SC 25 to SC 60
LPS-RK_SP
FRS-R, NOS
JJS
LPJ_SP, LP-CC
FNQ-R, JKS, KTK-R,
TCF, SC 12 to SC 20,
FCF_RN
No Motor Load
Fuse recommendations
Volts
0-250
0-300
0-600
0-600
0-600
Combination Motor
Loads and Other Loads
Motor Loads
150%* of the FLA of largest motor (if there are two or more
motors of same size, one is considered to be the largest) plus
the sum of all the FLA for all other motors plus 100% of noncontinuous, non-motor load plus 125% of continuous, nonmotor load.
150%* of the FLA of largest motor (if there are two or more
motors of same size, one is considered to be the largest) plus
the sum of all the FLA for all other motors.
Fuse(s)
LPN-RK_SP, FRN-R
JJN
LPS-RK_SP, FRS-R
JJS
LPJ_SP, LP-CC
JKS, KTK-R, LPT
Fuse recommendations
Volts
0-25O
0-600
0-600
Fuse(s)
LPN-RK_SP, FRN-R
LPS-RK_SP, FRS-R
LPJ- SP, LP-CC
*A max. of 175% (or the next standard size if 175% does not
correspond to a standard size) is allowed for all but wound
rotor and all dc motors.
1007July 2015
Fuse recommendation
Volts
0-600
Eaton.com/bussmannseries
Fuse(s)
KRP-C_SP
xvii
Backup overload w/
motor starter and shortcircuit protection
Fuse recommendations
125% of motor FLA or next size larger.
Volts
0-250
0-600
Fuse(s)
FRN-R
FRS-R
Fuse recommendations
130% of motor FLA or next size larger.
Short-circuit only
Short-circuit only
175%* of motor FLA or next size larger. (If 175% does not
correspond to a standard size). If this will not allow motor to
start, due to higher than normal inrush currents or longer than
normal acceleration times (5 sec. or greater), fuse may be
sized up to 225% or next size smaller.
Max. of 300%* of motor FLA or next size larger (if 300% does
not correspond to a standard size). If this will not allow motor
to start due to higher than normal inrush currents or longer
than normal acceleration times (5 sec. or greater), fuses
through 600 amps may be sized up to 400% or next size
smaller.
Volts
0-250
0-600
Fuse recommendations
Volts
0-250
0-600
Compare the min. melting time-current characteristics of the fuses with the time-current characteristics of the overload relay
curve. The size fuse which is selected should be such that short.circuit protection is provided by the fuse and overload
protection is provided by the controller overload relays.
Fuse(s)
LPN-RK_SP, FRN-R
LPS-RK_SP, FRS-R
LPJ_SP, TCF
Fuse recommendations
Volts
0-250
0-300
0-600
Above 600V
Fuse(s)
LPN-RK_SP
LPS-RK_SP
Fuse(s)
KTN-R
JJN
KTS-R
JJS
LP-CC, JKS, KTK-R,
LPT, FCF_RN
Fuse recommendations
Volts
2400
4800
7200
Fuse(s)
JCK, JCK-A, JCH
JCL, JCL-A, JCG
JCR, 7.2 WKMSJ
Solenoids (coils)
Fuse recommendation
Branch circuit
fuses
Volts
0-250
0-600
0-600
Supplementary
fuses
Fuse recommendation
Volts
0-32
0-125
0-250
0-500
xviii
1007July 2015
Eaton.com/bussmannseries
Fuse(s)
Best: LPN-RK_SP
FRN-R
LPS-RK_SP
FRS-R
LPJ_SP, LP-CC
FNQ-R, TCF
Fuse(s)
MDL 9-30A,
FNM 20-30A
MDA 25-30A,
FNM 12-15A
MDL 116-8A,
MDA 210-20A,
FNM 110-10A,
MDQ 1100-7A
FNQ 110-30A
Primary and
secondary
protection
Without thermal
overload
protection
With thermal
overload
protection
Transformer
impedance of 6%
or less
Transformer
impedance of
more than 6% but
less than 10%
NEC maximums
Optimum protection
C
D
Maximum Fuse
fuse size
Maximum
Size
% of primary FLA
(or next FLA size smaller)
A = 250%
B = 250%
C = 600%
D = 600%
E = 400%
F = 400%
% of secondary FLA
A = 167% or next size smaller
B = 125% or next size larger*
C = 167% or next size smaller
D = 125% or next size larger*
E = 167% or next size smaller
F = 125% or next size larger*
Fuse recommendations
Volts
250V
600V
Fuse(s)
LPN-RK_SP, FRN-R
KRP-C_SP, LPJ_SP, LPS-RK_SP, FNQ-R, FRS-R, TCF
1007July 2015
Eaton.com/bussmannseries
xix
Primary
protection
only
Primary
and
secondary
protection
Transformer
impedance less than
or equal to 6%
Primary
at code
max. of
300%
Secondary
Over 600V
Secondary at
code max. of
250%
Secondary
600V or
Below
Secondary at
code max. of
250%
Fuse Recommendations
Transformer impedance greater than 6%
but less than 10%
Unsupervised
installations
Transformer
impedance Less than
or equal to 6%
Transformer
impedance greater
than 6% but less
than 10%
Primary
at code
max.of
300%
Secondary
Over 600V
Secondary at
code max. of
225%
Secondary
600V or
Below
Secondary at
code max. of
250%
Secondary
Over 600V
Secondary
600V or
Below
Secondary
Over 600V
Secondary
600V or
Below
Volts
250V
600V
Fuse(s)
LPN-RK_SP, FRN-R
LPS-RK_SP, LPJ-_SP,
KRP-C_SP, FRS-R, FNQ-R,
TCF
2475V
JCD
2750V
JCX
2750/5500V JCW
5500V
MV05, 5.5 ABWNA,
5.5 AMWNA, 5.5 FFN
7200V
7.2 AMWNA, 7.2 TDLSJ,
7.2 TFLSJ
8300V
JCZ, JDZ, 8.25 FFN
15500V
MV155, 15.5 CAVH
17500V
17.5 CAV, 17.5 TDM
24000V
24 TDM, 24 TFM, 24 FFM
36000V
36 CAV, 36 TDQ, 36 TFQ
38000V
38 CAV
Short-circuit
protection only
Volts
0-130
0-250
0-500
0-600
0-700
0-1000
xx
1007July 2015
Eaton.com/bussmannseries
Fuse(s)
FWA
FWX
FWH
FWC, KAC, KBC
FWP, 170M Series,
SPP
FWJ, 170M Series,
SPJ
Contents
Page
1-2
1-5
Volts
600V . . . . .
600V . . . . .
600V . . . . .
1-7
1-8
1-9
CF . . . . . . . TCF*. . . . . . . . . . . . . . . . .
FCF. . . . . . . . . . . . . . . . . .
WCF. . . . . . . . . . . . . . . . .
*Class J performance
600V . . . . .
600V . . . . .
600V . . . . .
1-10
1-12
1-14
CF . . . . . . . Holder system. . . . . . . . . .
600V . . . . .
1-16
G . . . . . . . . SC . . . . . . . . . . . . . . . . . .
600/480V. .
1-18
J . . . . . . . . LPJ-_SP . . . . . . . . . . . . .
LPJ-_SPI indicator . . . . . .
JKS . . . . . . . . . . . . . . . . .
600V . . . . .
600V . . . . .
600V . . . . .
1-19
1-19
1-20
K5 and H. . . NON . . . . . . . . . . . . . . . .
NOS . . . . . . . . . . . . . . . .
250V . . . . .
600V . . . . .
1-21
1-21
L . . . . . . . . KRP-C_SP . . . . . . . . . . . .
KRP-CL . . . . . . . . . . . . . .
KLU . . . . . . . . . . . . . . . . .
KTU . . . . . . . . . . . . . . . . .
600V . . . . .
600V . . . . .
600V . . . . .
600V . . . . .
1-22
1-23
1-24
1-24
RK1 . . . . . . LPN-RK_SP . . . . . . . . . . .
LPN-RK_SPI indicator . . . .
LPS-RK_SP . . . . . . . . . . .
LPS-RK_SPI indicator . . . .
KTN-R . . . . . . . . . . . . . . .
KTS-R . . . . . . . . . . . . . . .
250V . . . . .
250V . . . . .
600V . . . . .
600V . . . . .
250V . . . . .
600V . . . . .
1-25
1-25
1-25
1-25
1-28
1-29
250V . . . . .
250V . . . . .
600V . . . . .
600V . . . . .
1-30
1-30
1-31
1-31
T. . . . . . . . . JJN . . . . . . . . . . . . . . . . .
JJS . . . . . . . . . . . . . . . . .
300V . . . . .
600V . . . . .
1-32
1-33
Plug fuses .
125V . . . . .
125V . . . . .
1-34
1-35
125V . . . . .
..........
1-36
1-36
SL, TL and W . . . . . . . . . .
P, S, T and TC . . . . . . . . .
MB Edison base circuit
breakers . . . . . . . . . . . . . .
SA fuse adapters . . . . . . . . .
1007July 2015
Eaton.com/bussmannseries
Low voltage
branch circuit
fuses
Description
Fuse holder and block selection guide
Class fuse dimensions
Fuses by fuse class
Class
Fuses
CC . . . . . . . LP-CC . . . . . . . . . . . . . . .
FNQ-R . . . . . . . . . . . . . . .
KTK-R . . . . . . . . . . . . . . .
1-1
Class
Fuses
Volts
CC
LP-CC
FNQ-R
KTK-R
600V . . . . . . . . . . . . . . . . . . . .1-7
600V . . . . . . . . . . . . . . . . . . . . 1-8
600V . . . . . . . . . . . . . . . . . . . . 1-9
Page
Holders
OPM-1038R and
OPM-1038RSW
OPM-NG-SC3
CHCC_D
Blocks
BCM panel/DIN-Rail mount . . . . . . . . . . . . . . . . . . . . . . . .9-32
HPF-RR
Class
Fuses
Volts
SC
600/480V . . . . . . . . . . . . . . . 1-18
BCM
HPS-RR
Page
Holders
HP front panel accessible, front panel mount . . . . . . . . . . 9-53
Blocks
HP
Class
Fuses
Volts
K5 and H
NON
NOS
250V . . . . . . . . . . . . . . . . . . .1-21
600V . . . . . . . . . . . . . . . . . . . 1-21
BG and G
Page
Blocks
Modular knifeblade
HM250
1-2
1007July 2015
Eaton.com/bussmannseries
Modular type
HM600
Fuses
Volts
KRP-C_SP
KRP-CL
KLU
KTU
600V . . . . . . . . . . . . . . . . . . .1-22
600V . . . . . . . . . . . . . . . . . . .1-23
600V . . . . . . . . . . . . . . . . . . .1-24
600V . . . . . . . . . . . . . . . . . . .1-24
Page
Low voltage
branch circuit
fuses
Class
Blocks
51215 1-pole, panel mount*
51235 3-pole, panel mount*
51215
Class
Fuses
Volts
RK1
LPN-RK_SP
LPS-RK_SP
KTN-R
250V . . . . . . . . . . . . . . . . . . .1-25
600V . . . . . . . . . . . . . . . . . . .1-25
250V . . . . . . . . . . . . . . . . . . .1-28
51235
Page
Blocks
Modular knifeblade fuse blocks 250/600V, panel mount . . 9-17
RM250 1- to 3-pole 250V, panel/DIN-Rail mount . . . . . . . 9-24
RM600 1- to 3-pole 600V, panel/DIN-Rail mount . . . . . . . 9-24
Class
Fuses
Volts
RK5
FRN-R
250V . . . . . . . . . . . . . . . . . . .1-30
Modular knifeblade
RM250
RM600
Modular knifeblade
RM250
RM600
Page
Blocks
Modular knifeblade fuse blocks 250/600V, panel mount . . 9-17
RM250 1- to 3-pole 250V, panel/DIN-Rail mount . . . . . . . 9-24
RM600 1- to 3-pole 600V, panel/DIN-Rail mount . . . . . . . 9-24
Class
Fuses
Volts
JJN
JJS
300V . . . . . . . . . . . . . . . . . . .1-32
600V . . . . . . . . . . . . . . . . . . .1-33
Page
Blocks
BH modular-style, panel mount (<60A) . . . . . . . . . . . . . . .9-41
T300 1- to 4-pole 300V, panel mount . . . . . . . . . . . . . . . .9-36
T600 1- to 3-pole 600V, panel mount . . . . . . . . . . . . . . . .9-38
T300
BH
1007July 2015
Eaton.com/bussmannseries
T600
1-3
Class
Fuses
Volts
J, CF
600V . . . . . . . . . . . . . . .1-10
600V . . . . . . . . . . . . . . .1-19
600V . . . . . . . . . . . . . . .1-20
*Class J performance
Page
Holders
TCFH CUBEFuse holder, panel/DIN-Rail mount . . . . . . . . . 1-16
CH Class J modular 1- to 3-pole, panel/
DIN-Rail mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-11
Safety J modular holders,
panel/DIN-Rail mount . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-14
TCFH
Modular type
Safety J
CH
Blocks
Power
distribution
fuse block
Modular
knifeblade
JP
Class
Fuses
Volts
Plug fuses
W, TL, T,
P and TC
JM600
JP
BH
Page
Fuse only
60
100
200
400
600
Desired fuse
(case) amp size
30
30
60
60
100
100
200
100
200
400
1-4
With switch
Catalog no.
(pairs) 250V
NO.263-R
NO.213-R
NO.216-R
NO.226-R
NO.2621-R
NO.2641-R
NO.242-R
NO.2661-R
NO.2662-R
NO.2664-R*
With grounded
outlet
60
Desired fuse
(case) amp size
100
200
400
600
30
30
60
60
100
100
200
100
200
400
1007July 2015
Eaton.com/bussmannseries
Catalog no.
(pairs) 600V
NO.663-R
NO.216-R
NO.616-R
NO.626-R
NO.2621-R
NO.2641-R
NO.642-R
NO.2661-R
NO.2662-R
NO.2664-R*
Amp Range
1-30
2.25 (57.2)
0.81 (20.6)
70-100
4.63 (117.5)
1.13 (28.6)
3.63 (92.1)
2.11 (53.6)
5.25 (133.3)
35-60
110-200
225-400
450-600
2.38 (60.3)
5.75 (146.1)
7.12 (181.0)
8.00 (203.2)
1.06 (27.0)
1.63 (41.4)
2.60 (66.0)
2.63 (66.7)
1.00 (25.4)
0.75 (28.6)
3.26 (82.8)
1.87 (47.6)
4.38 (111.1)
3.00 (76.2)
6.00 (152.4)
3.31 (84.0)
0.63 (15.9)
1.38 (34.9)
2.12 (54.0)
1A to 60A
1.13 (28.6)
1.62 (41.2)
2.00 (50.8)
A
C
D
A
E
0.50 (12.7)
0.41 (10.4)
0.19 (4.8)
0.38 (9.5)
0.25 (6.4)
0.53 (13.5)
0.13 (3.2)
I F
0.56 (14.2)
0.72 (18.3)
Low voltage
branch circuit
fuses
0.28 (7.1)
0.28 (7.1)
0.40 (10.3)
0.53 (13.5)
70A to 600A
0.41" (0.005)
(10.3mm)
Basic dimensions are same as Class H, one-time (NON and NOS) and superlag renewable RES and REN fuses. NOTE: These
fuses can be used to replace existing Class H, RK1 and RK5 fuses relating to dimensional compatibility.
Ferrule styles
Amp
range
10-30
35-60
250V
A
2 (50.8)
3 (76.2)
0.56 (14.3)
0.81 (20.6)
600V
A
5.0 (127.0)
5.5 (139.7)
0.81 (20.6)
1.06 (27.0)
250V
A
600V
A
70-100
5.88 (149.2)
1.06 (26.9)
7.88 (200.0)
1.34 (34.0)
225-400
8.63 (219.1)
2.38 (60.5)
11.63 (295.3)
2.59 (65.8)
110-200
450-600
7.13 (181.0)
10.38 (263.5)
1.56 (39.6)
9.63 (244.5)
2.88 (73.2)
13.38 (339.7)
600V
A
1.84 (46.7)
A
B
3.13 (79.5)
70-100
5.88 (149.2)
1.16 (29.5)
7.88 (200.0)
1.16 (29.5)
225-400
8.63 (219.1)
2.38 (60.5)
11.63 (295.3)
2.38 (60.5)
110-200
450-600
250V
A
7.13 (181.0)
10.38 (263.5)
1.66 (42.2)
2.88 (73.2)
9.63 (244.5)
13.38 (339.7)
1.66 (42.2)
2.88 (73.2)
1007July 2015
Eaton.com/bussmannseries
1-5
601-800
8.63 (219.1)
2.40 (61.0)
C1
6.75 (171.5)
C2
5.75 (146.1)
3.75 (95.3)
2.00 (50.8)
0.38 (9.5)
0.63 (15.9)
J1
J2
J3
J4
3.00 (76.2)
6.75 (171.5)
5.75 (146.1)
3.75 (95.3)
2.38 (60.3)
0.44 (11.1)
0.63 (15.9)
801-1200
10.75 (273.1)
2.40 (61.0)
6.75 (171.5)
5.75 (146.1)
3.75 (95.3)
2.00 (50.8)
0.38 (9.5)
0.63 (15.9)
1800-2000
10.75 (273.1)
3.50 (88.9)
6.75 (171.5)
5.75 (146.1)
3.75 (95.3)
2.75 (69.9)
0.50 (12.7)
0.63 (15.9)
1350-1600
2001-2500
3000
3500-4000
4500-5000
6000
10.75 (273.1)
10.75 (273.1)
10.75 (273.1)
10.75 (273.1)
10.75 (273.1)
10.75 (273.1)
4.80 (122.0)
5.00 (127.0)
5.75 (146.1)
6.25 (158.8)
7.13 (181.0)
6.75 (171.5)
6.75 (171.5)
6.75 (171.5)
6.75 (171.5)
6.75 (171.5)
5.75 (146.1)
5.75 (146.1)
5.75 (146.1)
5.75 (146.1)
5.75 (146.1)
3.75 (95.3)
3.50 (88.9)
3.75 (95.3)
4.00 (101.6)
3.75 (95.3)
4.75 (120.7)
3.75 (95.3)
5.25 (133.4)
3.75 (95.3)
5.75 (146.1)
0.75 (19.1)
0.75 (19.1)
0.75 (19.1)
1.00 (25.4)
1.00 (25.4)
0.63 (15.9)
0.63 (15.9)
0.63 (15.9)
0.63 (15.9)
0.63 (15.9)
1.75 (44.5)
1.75 (44.5)
1.75 (44.5)
1.75 (44.5)
1.75 (44.5)
J3
J2
C2
1.38 (34.9)
1.38 (34.9)
0.88 (22.2)
1.63 (41.3)
1.63 (41.3)
1.63 (41.3)
0.81 (20.6)
0.81 (20.6)
0.88 (22.2)
0.88 (22.2)
0.88 (22.2)
J2
J4
801A
to
2000A
C1
601A
to
800A
1.38 (34.9)
J1
J4
1.38 (34.9)
0.88 (22.2)
J3
J1
1.38 (34.9)
2001A
to
3000A
3500A
to
4000A
4500A
to
6000A
G
D
F
B
Amp range
35-60
0.88 (22.2)
1-30
70-100
0.88 (22.2)
0.41 (10.3)
2.16 (54.8)
0.75 (19.1)
1.56 (39.7)
0.84 (21.4)
0.56 (14.3)
110-200
2.44 (61.9)
0.88 (22.2)
1.69 (42.9)
0.84( 21.4)
450-600
3.06 (77.8)
1.25 (31.8)
2.03 (51.6)
0.88 (22.2)
225-400
601-800
801-1200
2.75 (69.9)
3.38 (85.7)
4.00 (101.6)
JJS 600V
Amp range
35-60
1.56 (39.7)
1-30
70-100
1.50 (38.1)
2.95 (75.0)
1.00 (25.4)
1.75 (44.5)
2.00 (50.8)
B
0.56 (14.3)
0.81 (20.6)
0.75 (19.1)
1.84 (46.8)
2.22 (56.4)
2.53 (64.3)
C
2..36 (59.9)
0.89 (22.6)
1.08 (27.4)
D
1.64 (41.7)
110-200
3.25 (82.6)
0.88 (22.2)
2.50 (63.5)
1.66 (42.1)
450-600
3.98 (101.2)
1.25 (31.8)
2.96 (75.0)
1.78 (45.2)
225-400
601-800
1-6
3.63 (92.1)
4.33 (109.9)
1.00 (25.4)
1.75 (44.5)
2.72 (69.1)
3.17 (80.6)
0.86 (21.8)
1.73 (44.1)
1.88 (47.6)
1007July 2015
Eaton.com/bussmannseries
AMP
RATING
20
25
30
3
3/
4
4/
6
8
10
12
15
200
Low voltage
branch circuit
fuses
Specifications:
Description: Time-delay, current-limiting,
rejection-type fuse 12 seconds (minimum)
at 200% rated amps.
Dimensions: 1332 x 1 12 (10.3 x 38.1mm).
Ratings:
Volts 600Vac (or less)
300Vdc (12-212A and 20-30A)
150Vdc (2810-15A)
Amps 12-30A
IR 200kA RMS Sym.
20kA DC
/
fl/
/
1
1/
LP-CC Class CC
100
CURRENT IN AMPS
1000
100
.01
10
.1
.4
TIME IN SECONDS
10
Typical applications:
Specialized circuits
Industrial control
Isolated, in-line fuse holder
Catalog numbers (amps)
LP-CC-12
LP-CC-2-12
LP-CC-7 12
LP-CC- 10
LP-CC-2- 10
LP-CC-8
LP-CC-810
LP-CC-3
LP-CC-9
LP-CC-1
LP-CC-3-210
LP-CC-10
LP-CC-1-18
LP-CC-3-12
LP-CC-12
LP-CC-1- 4
LP-CC-4
LP-CC-15
LP-CC-1-410
LP-CC-4-12
LP-CC-20
LP-CC-1-12
LP-CC-5
LP-CC-25
LP-CC-1-610
LP-CC-5-610
LP-CC-30
LP-CC-1-8 10
LP-CC-6
LP-CC-2
LP-CC-6-14
LP-CC-2-14
LP-CC-7
1007July 2015
Eaton.com/bussmannseries
1-7
FNQ-R-7-1/2
FNQ-R-5
FNQ-R-3
FNQ-R-1
100
AMP
RATING
10
TIME IN SECONDS
Specifications:
Description: Time-delay, branch circuit,
rejection-type fuse.
Dimensions: 1332 x 1 12 (10.3 x 38.1mm).
Ratings:
Volts 600Vac (or less)
300Vdc (15-20A)
32Vdc (Self Certified)
Amps 14-30A
IR 200kA RMS Sym.
20kA DC (15 and 20A only)
Agency information: CE, Std. 248-4, Class CC, UL Listed,
Guide JDDZ, File E4273 CSA Certified,
Class 1422-01, File 53787, RoHS compliant.
FNQ-R-1/2
FNQ-R Class CC
0.1
FNQ-R-2
FNQ-R-7
FNQ-R-12
FNQ-R-2-14
FNQ-R-7-12
FNQ-R-610
FNQ-R-2-12
FNQ-R-8
FNQ-R-34
FNQ-R-2-810
FNQ-R-9
FNQ-R-810
FQN-R-3
FNQ-R-10
FNQ-R-1
FNQ-R-3-210
FNQ-R-12
FNQ-R-1-18
FNQ-R-3-12
FNQ-R-15
FNQ-R-1-14
FNQ-R-4
FNQ-R-17-12
FNQ-R-1- 10
FNQ-R-4- 2
FNQ-R-1-410
FNQ-R-5
FNQ-R-25
FNQ-R-1-12
FNQ-R-5-610
FNQ-R-30
0.01
200
FNQ-R- 10
CURRENT IN AMPS
300
400
500
FNQ-R-6-14
100
FNQ-R-6
FNQ-R-1-810
10
FNQ-R-1-610
FNQ-R-310
0.08
FNQ-R-14
FNQ-R-20
1-8
1007July 2015
Eaton.com/bussmannseries
KTK-R Class CC
Low voltage
branch circuit
fuses
Specifications:
Description: Fast-acting, branch circuit,
rejection-type fuse.
Dimensions: 1332 x 1 12 (10.3 x 38.1mm).
Ratings:
Volts 600Vac (or less)
Amps 110-30A
IR 200kA RMS Sym.
Agency information: CE, Std. 248-4, Class CC,
UL Listed, Guide JDDZ, File E4273 CSA
Certified, File 53787, Class 1422-02, RoHS
compliant.
Features and benefits:
Current limitation at Class CC levels provides maximum
component short-circuit current protection.
200kA interrupting rating provides high ratings for control
circuit locations.
Class CC rejection feature, with appropriate fuse block,
prevents inserting lesser-rated supplementary fuses.
Typical applications:
Specialized circuits
Industrial control
Isolated, in-line fuse holders (street lighting)
Catalog numbers (amps)
KTK-R-110
KTK-R-1
KTK-R-7
KTK-R-18
KTK-R-1-12
KTK-R-8
KTK-R-210
KTK-R-2
KTK-R-9
KTK-R-14
KTK-R-2-12
KTK-R-10
KTK-R-310
KTK-R-3
KTK-R-12
KTK-R-410
KTK-R-3-12
KTK-R-15
KTK-R-12
KTK-R-4
KTK-R-20
KTK-R-610
KTK-R-5
KTK-R-25
KTK-R-34
KTK-R-6
KTK-R-30
1007July 2015
Eaton.com/bussmannseries
1-9
TCF10
Available with
indication
TCF15
TCF50
TCF35
TCF70
TCF30
TCF17- 2
TCF20
TCF25
TCF40
TCF45
TCF60
TCF80
TCF90
TCF17-12RN
TCF6RN
TCF25RN
TCF3RN
Specifications:
Description: Finger-safe fuse and fuse holder system;
dual-element, time-delay fuse; 10 seconds minimum
operating time at 500% rated amps.
Dimensions: See dimensions illustration.
Poles: 1-pole (gangable)
Ratings:
Volts 600Vac (or less)
300Vdc (or less)
Amps 1-100A
IR 300kA RMS Sym. (UL)
200kA RMS Sym. (CSA)
100kA DC (ULand CSA)
Agency information: CE, UL Listed Guide JDDZ, File
E4273, CSA Certified Fuse: Class 1422- 02, File 53787, UL
Listed Fuse holder: Guide IZND, File E214079, CSA
Certified Fuse holder: Class 6225-01, File 47235.
TCF10RN
TCF15RN
TCF40RN
TCF20RN
TCF45RN
TCF30RN
TCF60RN
TCF35RN
TCF100
TCF50RN
TCF80RN
TCF90RN
TCF100RN
TCF70RN
Carton
qty.
12
12
6
1-10
1007July 2015
Eaton.com/bussmannseries
10
Dimensions in (mm)
Low voltage
branch circuit
fuses
Fuse
amps
1-15
17 12
20
25-30
35-40
45-50
60
70
80-90
100
11
A
1.88
(47.75)
1.88
(47.75)
1.88
(47.75)
1.88
(47.75)
2.13
(54.10)
2.13
(54.10)
2.13
(54.10)
3.01
(76.45)
3.01
(76.45)
3.01
(76.45)
B
0.75
(19.05)
0.75)
(19.05)
0.75)
(19.05)
0.75
(19.05)
1.00
(25.40)
1.00
(25.40)
1.00
(25.40)
1.00
(25.40)
1.00
(25.40)
1.00
(25.40)
Dimensions - in (mm)
C
D
E
1.00
0.23
0.04
(25.40)
(5.84)
(1.02)
1.00
0.31
0.04
(25.40)
(7.87)
(1.02)
1.00
0.31
0.04
(25.40)
(7.87)
(1.02)
1.00
0.31
0.04
(25.40)
(7.87)
(1.02)
1.13
0.36
0.04
(28.58)
(9.10)
(1.02)
1.13
0.44
0.04
(28.58) (11.13)
(1.02)
1.13
0.44
0.04
(28.58) (11.13)
(1.02)
1.26
0.49
0.06
(32.00) (12.45)
(1.60)
1.26
0.49
0.06
(32.00) (12.45)
(1.60)
1.26
0.57
0.06
(32.00) (14.48)
(1.60)
F
0.63
(15.93)
0.63
(15.93)
0.63
(15.93)
0.63
(15.93)
0.63
(15.93)
0.63
(15.93)
0.63
(15.93)
0.58
(14.78)
0.58
(14.78)
0.58
(14.78)
G
0.28
(7.11)
0.28
(7.11)
0.28
(7.11)
0.28
(7.11)
0.38
(9.65)
0.38
(9.65)
0.38
(9.65)
0.38
(9.65)
0.38
(9.65)
0.38
(9.65)
1007July 2015
Eaton.com/bussmannseries
1-11
FCF20RN
FCF45RN
FCF90RN
FCF6RN
FCF30RN
FCF60RN
FCF3RN
FCF10RN
FCF15RN
FCF25RN
FCF35RN
FCF40RN
FCF50RN
FCF70RN
FCF80RN
Other ratings/specifications:
Watts loss at rated current: FCF15RN: 3.48W
FCF30RN: 5.45W
FCF60RN: 7.27W
Operating and storage temperature range:
-40 to 80C
Material specifications:
Case: glass filled PES (Polyethersulfone)
Terminals: copper alloy
Terminal plating: electroless tin
Carton quantity and weight
Amp
rating
1-30A
35-60A
70-100A
1-12
1007July 2015
Eaton.com/bussmannseries
FCF100RN
Dimensions in (mm)
Low voltage
branch circuit
fuses
100,000
100A
60A
10,000
30A
15A
1,000
100,000
10,000
1,000
100
300,000
A
100
1-15
20
25-30
35-40
45-50
60
70
80-90
100
A
1.88
(47.75)
1.88
(47.75)
1.88
(47.75)
2.13
(54.10)
2.13
(54.10)
2.13
(54.10)
3.01
(76.45)
3.01
(76.45)
3.01
(76.45)
B
0.75
(19.05)
0.75
(19.05)
0.75
(19.05)
1.00
(25.40)
1.00
(25.40)
1.00
(25.40)
1.00
(25.40)
1.00
(25.40)
1.00
(25.40)
Dimensions - in (mm)
C
D
E
1.00
0.23
0.04
(25.40)
(5.84)
(1.02)
1.00
0.31
0.04
(25.40)
(7.87)
(1.02)
1.00
0.31
0.04
(25.40)
(7.87)
(1.02)
1.13
0.36
0.04
(28.58)
(9.10)
(1.02)
1.13
0.44
0.04
(28.58) (11.13)
(1.02)
1.13
0.44
0.04
(28.58) (11.13)
(1.02)
1.26
0.49
0.06
(32.00) (12.45)
(1.60)
1.26
0.49
0.06
(32.00) (12.45)
(1.60)
1.26
0.57
0.06
(32.00) (14.48)
(1.60)
F
0.63
(15.93)
0.63
(15.93)
0.63
(15.93)
0.63
(15.93)
0.63
(15.93)
0.63
(15.93)
0.58
(14.78)
0.58
(14.78)
0.58
(14.78)
G
0.28
(7.11)
0.28
(7.11)
0.28
(7.11)
0.38
(9.65)
0.38
(9.65)
0.38
(9.65)
0.38
(9.65)
0.38
(9.65)
0.38
(9.65)
100A
30A
40A
50A
60A
20A
15A
6A
100
TIME IN SECONDS
Fuse
amps
10A
1000
3A
1A
10
0.1
10,000
CURRENT IN AMPS
1,000
100
10
0.01
1007July 2015
Eaton.com/bussmannseries
1-13
WCF 690V
Agency information:
UL Recognized Fuse: Guide JFHR, File E56412
cURus component certified C22.2
CE compliance for the European Union low voltage
directive
Other ratings/specifications:
Watts loss at rated current:
WCF15RN: 3.48W
WCF30RN: 5.45W
WCF60RN: 7.27W
WCF100RN: 11.50W
Operating and storage temperature range: -40 to 90C
Material specifications:
Case: glass filled PES (Polyethersulfone)
Terminals: copper alloy
Terminal plating: electroless tin
Installation:
Fits 690V WCF holders. See page 1-16
Application:
Wind systems:
- Transformer protection
- Pitch and speed control
- Turbine HVAC and lighting
Amp
rating
1-30A
35-60A
70-100A
Carton
qty.
12
12
6
1-14
1007July 2015
Eaton.com/bussmannseries
WCF100RN
Dimensions in (mm)
100A
60A
50A
40A
35A
10,000
1,000
300,000
100,000
10,000
100
100
1,000
1-15
20
25-30
35-40
45-50
60
70
80-90
100
A
1.88
(47.75)
1.88
(47.75)
1.88
(47.75)
2.13
(54.10)
2.13
(54.10)
2.13
(54.10)
3.01
(76.45)
3.01
(76.45)
3.01
(76.45)
B
0.75
(19.05)
0.75)
(19.05)
0.75
(19.05)
1.00
(25.40)
1.00
(25.40)
1.00
(25.40)
1.00
(25.40)
1.00
(25.40)
1.00
(25.40)
Dimensions - in (mm)
C
D
E
1.00
0.23
0.04
(25.40)
(5.84)
(1.02)
1.00
0.31
0.04
(25.40)
(7.87)
(1.02)
1.00
0.31
0.04
(25.40)
(7.87)
(1.02)
1.13
0.36
0.04
(28.58)
(9.10)
(1.02)
1.13
0.44
0.04
(28.58) (11.13)
(1.02)
1.13
0.44
0.04
(28.58) (11.13)
(1.02)
1.26
0.49
0.06
(32.00) (12.45)
(1.60)
1.26
0.49
0.06
(32.00) (12.45)
(1.60)
1.26
0.57
0.06
(32.00) (14.48)
(1.60)
F
0.63
(15.93)
0.63
(15.93)
0.63
(15.93)
0.63
(15.93)
0.63
(15.93)
0.63
(15.93)
0.58
(14.78)
0.58
(14.78)
0.58
(14.78)
G
0.28
(7.11)
0.28
(7.11)
0.28
(7.11)
0.38
(9.65)
0.38
(9.65)
0.38
(9.65)
0.38
(9.65)
0.38
(9.65)
0.38
(9.65)
100A
30A
40A
50A
60A
20A
15A
6A
100
TIME IN SECONDS
Fuse
Amps
10A
1000
3A
1A
10
0.1
10,000
CURRENT IN AMPS
1,000
100
10
0.01
1007July 2015
Eaton.com/bussmannseries
1-15
Low voltage
branch circuit
fuses
100,000
690V (Wind)
TCFH30NW
TCFH60NW
TCFH100NW
Construction: Finger-safe
Ampacity
(holds any CUBEFuse)
(1-30A)
(1-60A)
(1-100A)
Ratings:
Material specifications:
Holder case: glass filled PBT
Interface clips: copper alloy
Interface clip plating: tin
Terminals: steel
DIN-Rail spring: stainless steel
Agency information:
UL Listed fuse holder: Guide IZLT, File E14853
CSA Certified fuse holder: Class 6225-01, File 47235
cURus component Certified
CE compliance for the European Union low voltage directive
690 self certified.
600
1-60
6-60
1-60
35-60
600
1-100
6-100
1-100
35-100
690
1-30
690
1-60
690
1-100
10-8AWG 25Lb-In
18-12AWG 20Lb-In
18-10AWG 25Lb-In*
TCFH60N / TCFH60NW
Single
Dual
14-10AWG 20Lb-In
8-4AWG 35Lb-In
18-10AWG 20Lb-In
8-6AWG 35Lb-In
TCFH100N / TCFH100NW
Single
Dual
18-10AWG 25Lb-In**
8-1AWG 40Lb-In
1007July 2015
Eaton.com/bussmannseries
6AWG 45Lb-In
Dimensions in (mm)
Low voltage
branch circuit
fuses
14-10
10-1
14-4
10-6
Dimensions - in (mm)
H
I
J
K
L
M
2.30
0.76
1.36
0.15
2.60
1.03
1.60
0.17
2.91
1.05
2.01
0.15
0.80
2.51
(73.81) (26.74) (50.93) (3.81) (20.39) (63.65)
1007July 2015
Eaton.com/bussmannseries
1-17
SC Class G
Specifications:
Description: Fast-acting (12-6A),
time-delay (7-60A) fuse.
Dimensions: See dimensions
illustration.
Ratings:
Volts 600Vac (12-20A)
480Vac (25-60A)
170Vdc (12-20A)
300Vdc (30 and 60A only)
Amps 12-60A
IR 100kA RMS Sym.
10kA DC
Agency information: CE, Std. 248-5,
Class G, UL Listed, Guide JDDZ, File E4273,
CSA Certified, Class 1422-01, File 53787,
RoHS compliant.
Features and benefits:
Current limiting for component protection, providing Class G
energy-limitation for branch circuit protection.
100kA interrupting rating provides cost-effective branch
circuit fusing.
Variations in length help prevent overfusing.
Typical applications:
Fusible branch panelboards
HVAC branch circuit protection
Catalog numbers (amps)
SC-6
SC-12
SC-30
SC-50
SC-3
SC-7
SC-15
SC-35
SC-60
SC-1- 2
SC-4
SC-8
SC-20
SC-40
SC-2
SC-5
SC-10
SC-25
SC-45
10,000
Length
2 to -15
1.31 (33.3)
Diameter
0.41 (10.4)
20
1.41 (35.8)
0.41 (10.4)
25 to -30
1.62 (41.2)
0.41 (10.4)
(Length)
35 to -60
2.25 (57.1)
0.41 (10.4)
0.41"
1,000
A
100
100
(10.41mm)
AMP
RATING
Fuse amps
60
30
20
15
1,000
100,000
SC-2-12
SC-1
10,000
SC-12
1-18
1007July 2015
Eaton.com/bussmannseries
LPJ-2-14SP
LPJ-8SP*
LPJ-50SP*
LPJ-250SP*
LPJ-2-810SP
LPJ-10SP*
LPJ-70SP*
LPJ-2SP
LPJ-2- 2SP
1
LPJ-3SP
LPJ-3-210SP
LPJ-3-12SP
LPJ-4SP
LPJ-7SP*
LPJ-9SP*
LPJ-12SP*
LPJ-15SP*
LPJ-17-12SP*
LPJ-20SP*
LPJ-45SP*
LPJ-60SP*
LPJ-175SP*
LPJ-225SP*
LPJ-300SP*
LPJ-400SP*
LPJ-450SP*
LPJ-110SP*
LPJ-600SP*
LPJ-100SP*
TIME IN SECONDS
600A
400A
125A
200A
250A
60A
80A
100A
30A
15A
10A
10,000
1,000
100
10
600A
400A
200A
100A
60A
10,000
30A
15A
1,000
A
100
LPJ-350SP*
LPJ-80SP*
LPJ-90SP*
100,000
AMP
RATING
LPJ-200SP*
200,000
LPJ-40SP*
CURRENT IN AMPS
300,000
LPJ-6SP*
LPJ-1-810SP
.01
100,000
LPJ-150SP*
LPJ-35SP*
.1
10,000
LPJ-30SP*
1,000
LPJ-5SP
10
100
LPJ-5-610SP
LPJ-125SP*
100
LPJ-1-610SP
LPJ-1- 4SP
LPJ-25SP*
Low voltage
branch circuit
fuses
AMP
RATING
200
Specifications:
Description:
Dual-element,
time-delay fuse;
10 seconds(minimum) at 500% rated amps. Now
available with optional indication on select ratings
(see catalog numbers table).
Dimensions: See page 1-5 for Class J dimensions.
Ratings:
Volts 600Vac (or less)
300Vdc (or less)
Amps 1-600A
IR 300kA RMS Sym.
100kA DC
Agency information: CE, UL Listed, Guide JFHR, File
E56412, CSA Certified (200k AIR) Class J per CSA-22.2 No.
248.8, Class 1422-02, File 53787, RoHS compliant.
6A
300
indication
LPJ-1SP
1A
Available with
3A
LPJ_SP Class J
LPJ-500SP*
*Available with optional permanent replace fuse indication. To order, place I at end of
catalog number. Example: LPJ-6SPI.
Available with silver plated terminals. Add SP/ in front of catalog number.
1007July 2015
Eaton.com/bussmannseries
1-19
TIME IN SECONDS
CURRENT IN AMPS
AMP
RATING
600
400
200
100
60
10,000
30
A
1,000
200,000
100,000
100,000
400,000
10,000
1-20
10,000
.01
1,000
.1
100
JKS-225
JKS-250
JKS-300
JKS-350
JKS-400
JKS-450
JKS-500
JKS-600
40
JKS-70
JKS-80
JKS-90
JKS-100
JKS-110
JKS-125
JKS-150
JKS-175
JKS-200
600A
10
1,000
JKS-15
JKS-20
JKS-25
JKS-30
JKS-35
JKS-40
JKS-45
JKS-50
JKS-60
400A
100
JKS-1
JKS-2
JKS-3
JKS-4
JKS-5
JKS-6
JKS-8
JKS-10
JKS-12
AMP
RATING
JKS
200A
300
100A
30A
Specifications:
Description: Fast-acting,
current-limiting fuse.
Dimensions: See page 1-5 for
Class J dimensions.
Ratings:
Volts 600Vac (or less)
Amps 1-600A
IR 200kA RMS Sym.
Agency information: CE, Std.
248-8, Class J, UL Listed, Guide
JDDZ, File E4273, CSA Certified, Class 1422-02,
File 53787.
60A
JKS Class J
1007July 2015
Eaton.com/bussmannseries
NOS-12
NOS-70
NOS-200
NOS-2
NOS-15
NOS-75
NOS-225
Specifications:
Description: General purpose,
non-current-limiting fuses.
Dimensions: See page 1-5 for
dimensions.
Ratings:
Volts NON:
250Vac
125Vdc (0-100A)
NOS:
600Vac
Amps 18-600A
IR 50kA RMS Sym. (NON and NOS Class
K5 0-60A)
10kA RMS Sym. (NON and NOS Class H 65-600A)
50kA @ 125Vdc (NON Class K5 0-60A)
10kA @ 125Vdc (NON Class H 65-100A)
Agency information: CE, UL Listed 250V: Class K5
(0-60A), Std. 248-9, Class H (65-600A), Std. 248-6, (125Vdc:
NON 0-100), 600V: Class K5 (0-60A), Std. 248-9, Class H
(70-600A), Std. 248-6, Guide JDDZ, File E4273, CSA
Certified 250V: (0-12, 65-600), 600V: (0-600), Class
1421-01, File 53787.
NOS-3
NOS-20
NOS-80
NOS-250
NOS-4
NOS-25
NOS-90
NOS-300
NOS-5
NOS-30
NOS-100
NOS-350
NOS-6
NOS-35
NOS-110
NOS-400
NOS-7
NOS-40
NOS-125
NOS-450
NOS-8
NOS-45
NOS-150
NOS-500
NOS-9
NOS-50
NOS-175
NOS-600
NOS-10
NOS-60
Low voltage
branch circuit
fuses
Clip
amp
size
30
100
60
200
30
60
100
100
200
100
200
400
60
100
600V
Fuse
amp
size
Clip
amp
size
Catalog
number
(pair)
NO.213
30
100
NO.216
NO.226
60
200
Catalog
number
(pair)
NO.263
NO.216
30
60
60
100
NO.663
NO.616
NO.626
200
NO.2621
100
200
NO.2621
400
NO.2642
200
400
NO.2642
400
600
600
600
NO.2641
NO.2661
NO.2662
NO.2664
100
100
200
400
400
600
600
600
NO.2641
NO.2661
NO.2662
NO.2664
NON-5
NON-40
NON-12
NON-6
NON-45
NON-175
NON-200
NON-34
NON-6-14
NON-50
NON-225
NON-810
NON-7
NON-60
NON-250
NON-1
NON-8
NON-65
NON-300
NON-1-14
NON-9
NON-70
NON-350
NON-1-12
NON-10
NON-75
NON-400
NON-1-610
NON-12
NON-80
NON-450
NON-2
NON-15
NON-90
NON-500
NON-2-12
NON-20
NON-100
NON-600
NON-3
NON-25
NON-110
NON-3-210
NON-30
NON-125
NON-4
NON-35
NON-150
1007July 2015
Eaton.com/bussmannseries
1-21
KRP-C_SP Class L
KRP-C-700SP
KRP-C-650SP
Specifications:
Description: Time-delay fuse 4
seconds (minimum) at 500% rated amps.
Dimensions: See page 1-6 for Class L
dimensions.
Ratings:
Volts 600Vac (or less)
300Vdc (601-2000A, 3000A)
Amps 601-6000A
(use KRP-CL for current ratings
under 601A)
IR 300kA RMS Sym.
100kA DC
Agency information: CE, UL Listed248-10, Guide JFHR, File E56412,
CSA Certified (200k AIR), Class 1422-02,
File 53787, Class L per CSA C22.2, No. 248.10, RoHS
compliant.
KRP-C-750SP
KRP-C-800SP
KRP-C-801SP
KRP-C-900SP
1-22
1007July 2015
Eaton.com/bussmannseries
AMP
RATING
100,000
10,000
1,000
300,000
1,000
6,000A
5,000A
4,000A
3,000A
2,500A
2,000A
1,600A
1,200A
800A
601A
100,000
10
10,000
100
TIME IN SECONDS
1000,000
4000A
5000A
6000A
1600A
2000A
2500A
3000A
800A
AMP
RATING
Low voltage
branch circuit
fuses
300
1200A
200,000
100,000
1,000
.01
10,000
.1
CURRENT IN AMPS
Class L case size for amp ratings from 225 to 600A allows
downsize fusing of large Class L fused switches for improved
circuit protection.
Typical applications:
Large distribution switchboards
Power panelboards
Machinery disconnects
Catalog numbers (amps)
KRP-CL-225
KRP-CL-350
KRP-CL-500
KRP-CL-250
KRP-CL-400
KRP-CL-600
KRP-CL-300
KRP-CL-450
1007July 2015
Eaton.com/bussmannseries
1-23
KTU Class L
KLU Class L
Specifications:
Description: Fast-acting, bolt-mount
fuse.
Dimensions: See page 1-6 for Class L
dimensions.
Ratings:
Volts 600Vac (or less)
Amps 601-6000A
IR 200kA RMS Sym.
Agency information: CE, Std. 248-10,
Class L, UL Listed, Guide JDDZ, File
E4273 CSA Certified, Class 1422-02,
File 53787, RoHS compliant.
Specifications:
Description: Time-delay, bolt-mount fuse
- 5 seconds (minimum) at 500% rated
amps. See KRP-CL for amp ratings below
601A.
Dimensions: See page 1-6 for Class L
dimensions.
Ratings:
Volts 600Vac (or less)
Amps 601-4000A
IR 200kA RMS Sym.
Agency information: CE, Std. 248-10,
Class L, UL Listed, Guide JDDZ, File E4273,
CSA Certified, CSA Class 1422-02, File 53787,
RoHS compliant.
KTU-601
KTU-1000
KTU-2001
KLU-601
KLU-1200
KLU-2500
KTU-650
KTU-1100
KTU-2400
KLU-650
KLU-1500
KLU-3000
KTU-700
KTU-1200
KTU-2500
KLU-700
KLU-1600
KLU-4000
KTU-750
KTU-1400
KTU-3000
KLU-800
KLU-1800
KTU-800
KTU-1500
KTU-3500
KLU-1000
KLU-2000
KTU-801
KTU-1600
KTU-4000
KTU-850
KTU-1800
KTU-5000
KTU-900
KTU-2000
KTU-6000
1-24
1007July 2015
Eaton.com/bussmannseries
Typical applications:
Large distribution switchboards
Power panelboards
Motor control centers
Machinery disconnect switches
Low voltage
branch circuit
fuses
Available with
Specifications:
Description:
Current-limiting,
dual-element,
time-delay fuse; 10 seconds
(minimum) at 500% rated amps
(8 seconds for 0-30A sizes).
Now available with optional
indication on select ratings
(see catalog numbers table).
Dimensions: See page 1-5 for
Class RK1 dimensions.
Ratings:
Volts LPN-RK:
250Vac (or less)
125Vdc (0-60A)
250Vdc (70-600A)
LPN-RK-110SP
LPN-RK-3-12SP
LPN-RK- 100SP
LPN-RK-4SP
LPN-RK-70SP*
LPN-RK-210SP
LPN-RK-4-12SP
LPN-RK-80SP*
LPN-RK-310SP
LPN-RK-5SP
LPN-RK-90SP*
LPN-RK-410SP
LPN-RK-5-610SP
LPN-RK-100SP*
15
LPN-RK-12SP
LPN-RK-6SP
LPN-RK-110SP*
LPN-RK-610SP
LPN-RK-6-14SP
LPN-RK-125SP*
LPN-RK-810SP
LPN-RK-8SP
LPN-RK-150SP*
LPN-RK-1SP
LPN-RK-9SP
LPN-RK-175SP*
LPN-RK-1-18SP
LPN-RK-10SP
LPN-RK-200SP*
LPN-RK-1-14SP
LPN-RK-12SP
LPN-RK-225SP*
LPN-RK-1-410SP
LPN-RK-15SP
LPN-RK-250SP*
LPN-RK-1-610SP
LPN-RK-17-12SP
LPN-RK-300SP*
LPN-RK-1- 1 SP
0
LPN-RK-20SP
LPN-RK-350SP*
LPN-RK-2SP
LPN-RK-25SP
LPN-RK-400SP*
LPN-RK-2-14SP
LPN-RK-30SP
LPN-RK-450SP*
LPN-RK-2-12SP
LPN-RK-35SP*
LPN-RK-500SP*
LPN-RK-2-810SP
LPN-RK-40SP*
LPN-RK-600SP*
LPN-RK-3SP
LPN-RK-45SP*
LPN-RK-3-210SP
LPN-RK-50SP*
LPS-RK:
LPN-RK-60SP*
*Available with optional indication. To order, place I at end of catalog number. Example:
LPN-RK-35SPI.
0-60A fuses available with Nickel plate option. (Ex: LPS-RK30SPNP) 70-600A fuses available
with Tin plate option. Example: LPS-RK-100SP-TP.
LPS-RK-2-14SP
LPS-RK-10SP*
LPS-RK- 10SP
LPS-RK-2-12SP
LPS-RK-12SP*
LPS-RK-110SP*
LPS-RK-310SP
LPS-RK-2-810SP
LPS-RK-15SP*
LPS-RK-125SP*
LPS-RK-410SP
LPS-RK-3SP
LPS-RK-17-12SP*
LPS-RK-150SP*
LPS-RK-12SP
LPS-RK-3-210SP
LPS-RK-20SP*
LPS-RK-175SP*
LPS-RK-610SP
LPS-RK-3-12SP
LPS-RK-25SP*
LPS-RK-200SP*
LPS-RK-810SP
LPS-RK-4SP
LPS-RK-30SP*
LPS-RK-225SP*
LPS-RK-1SP
LPS-RK-4-12SP
LPS-RK-35SP*
LPS-RK-250SP*
LPS-RK-1-18SP
LPS-RK-5SP
LPS-RK-40SP*
LPS-RK-300SP*
LPS-RK-1-14SP
LPS-RK-5-610SP
LPS-RK-45SP*
LPS-RK-350SP*
LPS-RK-1-410SP
LPS-RK-6SP*
LPS-RK-50SP*
LPS-RK-400SP*
LPS-RK-1-12SP
LPS-RK-6-14SP*
LPS-RK-60SP*
LPS-RK-450SP*
LPS-RK-1-610SP
LPS-RK-7SP*
LPS-RK-70SP*
LPS-RK-500SP*
LPS-RK-1-810SP
LPS-RK-8SP*
LPS-RK-80SP*
LPS-RK-600SP*
LPS-RK-2SP
LPS-RK-9SP*
LPS-RK-90SP*
LPS-RK-100SP*
*Available with optional replace fuse indication. To order, place I at end of Catalog
Number. Example: LPS-RK-15SPI.
1007July 2015
Eaton.com/bussmannseries
1-25
61/4
4
5
8
10
12
11/4
21/2
32/10
300
AMP RATING
16/10
400 600
1/2
200
8/10
100
6/10
60
3/10
4/10
15 20 30
1/10
300
2/10
LPN-RK
15/100
LPN-RK
AMP RATING
100
100
10
TIME IN SECONDS
1,000
10
61/4
10
AMP RATING
32/10
400 600
200
11/4
100
1
16/10
21/2
4
5
8
12
60
8/10
30
1 /2
6/10
20
4/10
300
2/10
LPS-RK
1/10
15/100
CURRENT IN AMPS
10,000
100
20
1,000
.1
.01
.01
100
.1
.1
3/10
TIME IN SECONDS
10
LPS-RK
AMP RATING
100
TIME IN SECONDS
TIME IN SECONDS
10
CURRENT IN AMPS
10,000
1,000
20
.01
100
.1
CURRENT IN AMPS
1-26
1007July 2015
Eaton.com/bussmannseries
AMP
RATING
400,000
Low voltage
branch circuit
fuses
100,000
600
400
200
100
60
10,000
30
200,000
100,000
1,000
10,000
1,000
1007July 2015
Eaton.com/bussmannseries
1-27
KTN-R-30
KTN-R-35
KTN-R-40
KTN-R-45
KTN-R-50
KTN-R-60
KTN-R-70
KTN-R-75
KTN-R-80
KTN-R-90
KTN-R-100
KTN-R-110
KTN-R-125
KTN-R-150
KTN-R-175
KTN-R-200
KTN-R-225
KTN-R-250
KTN-R-300
KTN-R-350
KTN-R-400
KTN-R-450
KTN-R-500
KTN-R-600
1-28
1007July 2015
Eaton.com/bussmannseries
Typical applications:
Panelboards
600A
400A
200A
60A
30A
100
10
TIME IN SECONDS
300
AMPERE
RATING
Low voltage
branch circuit
fuses
Specifications:
Description: Fast-acting, current-limiting
fuse.
Dimensions: See page 1-5 for Class RK1
dimensions.
Ratings:
Volts 600Vac (or less)
Amps 1-600A
IR 200kA RMS Sym.
Agency information: CE, Std. 248-12,
Class RK1, UL Listed, Guide JDDZ, File
E54273, CSA Certified, C22.2 No. 248.12, Class
1422-02, File 53787.
100A
.1
10,000
.01
1,000
400,000
AMPERE
RATING
KTS-R-125
KTS-R-150
KTS-R-175
KTS-R-200
KTS-R-225
KTS-R-250
KTS-R-300
KTS-R-350
KTS-R-400
KTS-R-450
KTS-R-500
KTS-R-600
40
KTS-R-30
KTS-R-35
KTS-R-40
KTS-R-45
KTS-R-50
KTS-R-60
KTS-R-70
KTS-R-75
KTS-R-80
KTS-R-90
KTS-R-100
KTS-R-110
KTS-R-1
KTS-R-2
KTS-R-3
KTS-R-4
KTS-R-5
KTS-R-6
KTS-R-8
KTS-R-10
KTS-R-12
KTS-R-15
KTS-R-20
KTS-R-25
100
100,000
100
10,000
60
30
1,000
200,000
100,000
200
10,000
400
1,000
600
1007July 2015
Eaton.com/bussmannseries
1-29
FRN-R-2-14
FRN-R-12*
FRN-R-110
FRN-R-15100
FRN-R-2-12
FRN-R-15*
FRN-R-125
FRN-R-210
FRN-R-2-810
FRN-R-17-12*
FRN-R-150
FRN-R-14
FRN-R-3
FRN-R-20*
FRN-R-175
FRN-R-310
FRN-R-3-210
FRN-R-25*
FRN-R-200
FRN-R-410
FRN-R-3-12
FRN-R-30*
FRN-R-225
FRN-R-12
FRN-R-4
FRN-R-35*
FRN-R-250
FRN-R-610
FRN-R-4-12
FRN-R-40*
FRN-R-300
FRN-R-810
FRN-R-5
FRN-R-45*
FRN-R-350
FRN-R-1
FRN-R-5-610
FRN-R-50*
FRN-R-400
FRN-R-1-18
FRN-R-6
FRN-R-60*
FRN-R-450
FRN-R-1-14
FRN-R-6-14
FRN-R-70
FRN-R-500
FRN-R-1-410
FRN-R-7
FRN-R-75
FRN-R-600
FRN-R-1-12
FRN-R-7-12
FRN-R-80
FRN-R-1-610
FRN-R-8*
FRN-R-85
FRN-R-1- 10
FRN-R-9*
FRN-R-90
*Available with indication. To order, place ID at the end of the catalog number.
Example: FRN-R-30ID
400
600
200
Amp
Rating
200
100
60
10,000
30
A
1,000
200,000
FRN-R-18
600
400
100,000
FRN-R-100
100,000
1,000
FRN-R-10*
FRN-R
10,000
400,000
Combination starters
Machinery disconnects
FRN-R-110
100
Typical applications:
Power panelboards
Motor control centers
60
8
10
15
Specifications:
Description: Dual-element, time-delay
fuse 10 seconds (minimum) at 500%
rated amps (8 seconds for 0-30A sizes).
Available with indication on select ratings
(see catalog numbers table).
Dimensions: See page 1-5 for Class RK5
dimensions.
Ratings:
Volts 250Vac (or less)
125Vdc (110-60A, 110-200A)
250Vdc (225-600A)
Available
Amps 110-600A
with
indication
IR 200kA RMS Sym.
20kA DC
Agency information: CE, Std. 248-12, Class RK5,
UL Listed, Guide JDDZ, File E4273, CSA Certified, Class
1422-01, File 53787.
30
1007July 2015
Eaton.com/bussmannseries
Low voltage
branch circuit
fuses
Specifications:
Description: Dual-element, time-delay fuse 10
seconds (minimum) at500% rated amps. Now
available with optional indication on select ratings
(see catalog numbers table).
Dimensions: See page 1-5 for Class RK5 dimensions.
Ratings:
Volts 600Vac (or less)
300Vdc 110-30A, 65-600
250Vdc 35-60A
Amps 110-600A
IR 200kA RMS Sym.
.
20kA DC
Available
with
indication
FRS-R-10*
FRS-R-12*
FRS-R-15*
FRS-R-17-12*
FRS-R-20*
FRS-R-25*
FRS-R-30*
FRS-R-35*
FRS-R-40*
FRS-R-45*
FRS-R-50*
FRS-R-60*
FRS-R-65
FRS-R-70
FRS-R-75
FRS-R-80
FRS-R-90
FRS-R-100
FRS-R-110
FRS-R-125
FRS-R-150
FRS-R-175
FRS-R-200
FRS-R-225
FRS-R-250
FRS-R-300
FRS-R-350
FRS-R-400
FRS-R-450
FRS-R-500
FRS-R-600
*Available with indication. To order, place ID at the end of the catalog number.
Example: FRS-R-7ID.
FRS-R (600V)
100,000
600A
400A
200A
100A
60A
30A
10,000
15A
A
1,000
200,000
FRS-R-2
FRS-R-2-14
FRS-R-2-12
FRS-R-2-810
FRS-R-3
FRS-R-3-210
FRS-R-3-12
FRS-R-4
FRS-R-4-12
FRS-R-5
FRS-R-5-610
FRS-R-6*
FRS-R-6-14*
FRS-R-7*
FRS-R-7-12*
FRS-R-8*
FRS-R-9*
1,000
FRS-R-110
FRS-R-18
FRS-R-15100
FRS-R-210
FRS-R-14
FRS-R-310
FRS-R-410
FRS-R-12
FRS-R-610
FRS-R-810
FRS-R-1
FRS-R-1-18
FRS-R-1-14
FRS-R-1-410
FRS-R-1-12
FRS-R-1-610
FRS-R-1 810
Amp
Rating
400,000
100,000
Combination starters
Machinery disconnects
10,000
Typical applications
Power panelboards
Motor control centers
1007July 2015
Eaton.com/bussmannseries
1-31
JJN-1
JJN-15
JJN-40
JJN-80
JJN-150
JJN-300
JJN-600
JJN-2
JJN-20
JJN-45
JJN-90
JJN-175
JJN-350
JJN-700
JJN-3
JJN-25
JJN-50
JJN-100
JJN-200
JJN-400
JJN-800
JJN-6
JJN-30
JJN-60
JJN-110
JJN-225
JJN-450
JJN-1000
JJN-10
JJN-35
JJN-70
JJN-125
JJN-250
JJN-500
JJN-1200
JJN
1007July 2015
Eaton.com/bussmannseries
Low voltage
branch circuit
fuses
Specifications:
Description: Very fast-acting,
current-limiting fuse.
Dimensions: See page 1-6 for Class T
dimensions.
Ratings:
Volts 600Vac (or less)
Amps 1-800A
IR 200kA RMS Sym.
Agency information: CE, Std. 248-15, Class T, UL Listed,
Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File
53787, RoHS compliant.
JJS
JJS-15
JJS-40
JJS-80
JJS-150
JJS-300
JJS-600
JJS-2
JJS-20
JJS-45
JJS-90
JJS-175
JJS-350
JJS-800
JJS-3
JJS-25
JJS-50
JJS-100
JJS-200
JJS-400
JJS
JJS-6
JJS-30
JJS-60
JJS-110
JJS-225
JJS-450
JJS-10
JJS-35
JJS-70
JJS-125
JJS-250
JJS-500
1007July 2015
1-33
Plug fuses
SL and TL
Specifications:
Description: Fast-acting plug
fuse.
Dimensions: Edison base plug.
Construction: Brass threads
with plastic body.
Ratings:
Volts 125Vac
Amps 12-12A
IR 10kA RMS Sym.
Agency information: CE, Std. 248-11, UL Listed, Guide
JEFV, File E12112.
Specifications
Description: Time-delay,
loaded link plug fuse.
Dimensions:
SL Rejection base
TL Edison base
Construction:
SL Plastic base with rejection threads
TL Brass threads with plastic body
Ratings:
Volts 125Vac
Amps 15-30A
IR 10kA RMS Sym.
Agency information: CE, Std. 248-11, UL Listed, Guide
JEFV, File E12112.
W-2 12
W-3
W-4
W-5
W-6
W-6 12
W-7
W-8
W-10
W-12
W-DUMMY**
*W-15, W-20, W-25, and W-30 plug fuses obsoleted. Suggest replacing with either T-(Amp)
or TL-(Amp) plug fuses.
** Non-conductive dummy base. Not a fuse.
SL-20
SL-25
SL-30
TL-20
TL-25
TL-30
1-34
1007July 2015
Eaton.com/bussmannseries
P and TC
Specifications:
Description: Dual-element, time-delay plug
fuse.
Dimensions:
S Rejection base
T Edison base
Construction:
S Plastic base with rejection threads
T Brass threads with plastic body
Ratings:
Volts 125Vac
Amps S: 14-30A
T: 310-30A
IR 10kA RMS Sym.
Agency information: CE, Std. 248-11, Type S and T:
UL Listed (0-614) Guide JFHR, File E56412 (7-30A) Guide
JEFV, File E12112; CSA Certified, Class 1423-01, File
53787.
Specifications:
Description:
P - Type P dual-element fuse
TC - Type D dual-element, time-delay fuse
Dimensions: Edison base
Construction: Brass threads with plastic
body.
Ratings:
Volts 125Vac or less
Amps 15-30A
IR 10kA
Agency information:
P - CSA Certified
TC - CSA Certified (Class 1423-01, File # 53787)
S-2-810
S-3
S-3-210
S-3-12
S-4
S-4-12
S-5
S-5-610
S-6
S-6-14
S-7
S-8
S-9
S-10
S-12
T-4
T-4-12
T-5
T-5-610
T-6
T-6-14
T-7
T-8
T-9
T-10
T-12
T-14
T-15
T-20
T-25
T-30
Low voltage
branch circuit
fuses
S and T
S-14
S-15
S-20
S-25
S-30
1007July 2015
Eaton.com/bussmannseries
1-35
Specifications:
Description: Edison base manual reset circuit breakers.
Dimensions: Edison base
Construction: Brass threads with plastic body
Ratings:
Volts 125Vac only
Amps 15-20A
IR 10kA RMS Sym.
Agency information: UL Listed, File E14942
Features and benefits:
Fit standard Edison base fuse receptacles.
Resettable upon overload event.
Typical applications:*
Replacing Edison base plug fuses in residential fuse panels.
Catalog numbers* (Amps)
MB-15
MB-20
* Not for use in box cover units or for inductive loads.
Specifications:
Description: Adapters for using Type S and SL rejection
fuses in Edison base fuse sockets.
Agency information: UL Listed, File E12853; CSACertified
File #6225-01, File #47235.
SA-1*
SA-1-14*
SA-1-610*
SA-2*
SA-2-12*
SA-3-210*
SA-4*
SA-5*
SA-6-14*
SA-8*
SA-10*
SA-15**
SA-20**
SA-30**
SA-1-14
SA-1-610
SA-2
SA-2-12
SA-3- 10
SA-4
SA-5
SA-6- 4
SA-8
SA-10
SA-15
SA-20
SA-30
Accepts fuses
S-1 or smaller
S-1-14 or smaller
S-1-610 or smaller
S-2 or S-1-810
S-2-12 to S-1-810
S-3-210 to S-1-810
S-4 to S-3-12
S-5 to S-3-12
S-6-14 to S-3-12
S-8 to S-7
S-10 to S-7
S-15 to S-7
S-20
S-30 to S-25
S-15 to S-7
SA 30
S-30 to S-25
SA-20
1-36
1007July 2015
Accepts fuses
SA-15
S-20
Eaton.com/bussmannseries
Solar fuses
Contents
Eaton.com/bussmannseries
2-1
Solar
products
Description
Page
Fuse holder and block selection guide
2-2
Volt
Fuses
Size
600Vdc . . . . . . . . . . .PVM . . . . . 13/32 x 1 1/2 . . . . . . . . . 2-4
600Vac /300Vdc . . . . PVCF. . . . .CUBEFuse . . . . . . . . . . 2-5
600Vac/dc . . . . . . . . .PVS-R. . . . RK5 . . . . . . . . . . . . . . . . . 2-7
1000Vdc . . . . . . . . . .PV. . . . . . .10x38mm . . . . . . . . . . . . . 2-8
1000Vdc . . . . . . . . . .HPV. . . . . .10x38mm
(in-line assembly). . . . . . . . 2-9
1000/1100Vdc . . . . . .PV . . . . . . .14x51mm . . . . . . . . . . . 2-10
1000Vdc . . . . . . . . . .NH. . . . . . .NH Sizes 1, 2, 3 . . . . . . . 2-11
1000Vdc . . . . . . . . . . XL PV . . . . XL Size 01, 1, 2, 3 . . . . . .2-12
1300/1500Vdc . . . . . .PV. . . . . . .14x65mm . . . . . . . . . . . . 2-15
1200/1500Vdc . . . . . .XL PV . . . . XL Size 01, 1, 2, 3 . . . . . 2-16
Solar fuses
600 Volts
Fuses
Midget . . . . . . . . . . . . . .
CF . . . . . . . . . . . . . . . . .
RK5 . . . . . . . . . . . . . . . .
PVM . . . . . . . . . . . 600V . . . . . . . . . .
CFPV . . . . . . . . . . 600V . . . . . . . . . .
PVS-R . . . . . . . . . 600V . . . . . . . . . .
Volts
Page
2-4
2-5
2-7
Holders
TCFH CUBEFuse holder, panel/DIN-Rail mount . . . . . . . . . . . . . 1-16
CHM DIN-Rail mount holders . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2
HEB in-line holders. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-46
Blocks
CHM
HEB
TCFH
BMM
Modular
knifeblade
R600
CHPV
CH14
HEB
SD1-D-PV
SB1XL-S
SB2XL-S
SB3L-S
HPV
1000 Volts
Fuses
Volts
10x38mm . . . . . . . . . . .
14x51mm . . . . . . . . . . .
NH Sizes 1, 2 and 3 . . . .
01XL . . . . . . . . . . . . . . .
1XL . . . . . . . . . . . . . . . .
2XL . . . . . . . . . . . . . . . .
3L . . . . . . . . . . . . . . . . .
PV-_A10 . . . . . . . .
PV-_A14 . . . . . . . .
PV-_ANH . . . . . . .
PV-_A-01XL . . . . .
PV-_A-1XL . . . . . .
PV-_A-2XL . . . . . .
PV-_A-3L . . . . . . .
1000V . . . . . . . . .
1000/1100V. . . . .
1000V . . . . . . . . .
1000V . . . . . . . . .
1000V . . . . . . . . .
1000V . . . . . . . . .
1000V . . . . . . . . .
Page
2-8
2-10
2-11
2-12
2-12
2-12
2-12
Holders
Blocks
2-12
2-12
2-12
2-11
2-11
2-11
2-2
Eaton.com/bussmannseries
Solar fuses
1500 Volts
Fuses
Volts
01XL . . . . . . . . . . .
1XL . . . . . . . . . . . .
2XL . . . . . . . . . . . .
3L . . . . . . . . . . . . .
14x65mm
PV-_A-01XL-15 . . . .
PV-_A-1XL-15 . . . . .
PV-_A-2XL-15 . . . . .
PV-_A-3L-15 . . . . . .
PV-_A14*. . . . . . . . .
1500V . . . . . . . . .
1500V . . . . . . . . .
1500V . . . . . . . . .
1500V . . . . . . . . .
1300/1500V. . . . .
Page
2-16
2-16
2-16
2-16
2-15
2-16
2-16
2-16
Blocks
SB1XL-S
SB2XL-S
SB3L-S
Solar
products
* Available with tags for bolt mounting or 10mm fixings for mounting in modular blocks for 10mm
diameter fuses.
** IEC only to 1500Vdc.
Eaton.com/bussmannseries
2-3
Solar fuses
Amp
rating
10
15
30
30 A
CURRENT IN AMPS
1,000
.01
15 A
20 A
.1
100
Typical applications:
Solar combiner boxes
Solar string protectors
10
AMP
RATING
10
TIME IN SECONDS
Specifications:
Description: A range of UL 2579
fast-acting 600Vdc Midget fuses specifically
designed to protect solor power systems in
extreme ambient temperature, high cycling
and low level fault current conditions (reverse
current, multi-array fault).
Dimensions: 1332 x 1 12
(10.3 x 38.1mm).
Ratings:
Volts 600Vdc to UL 2579
Amps 4-30A
IR 50kA DC (4-30A)
Agency information: UL Listed 2579, Guide JFGA, File
E335324, CSA Component Certified C22.2. RoHS compliant.
100
8A
10 A
PVM
5A
In = Rated current
PVM-7
PVM-10
PVM-20
PVM-5
PVM-8
PVM-12
PVM-25
PVM-6
PVM-9
PVM-15
PVM-30
Dimensions - (mm)
1.5"
0.031
(38.1mm)
0.407"
0.005
(10.3mm)
Eaton.com/bussmannseries
Solar fuses
Photovoltaic CUBEFuse
PVCF 600V
Agency information:
UL 2579 Listed Fuse: Guide JFGA, File E335324
CSA Certified Fuse: Class C22.2
RoHS compliant
PVCF50RN
PVCF80RN
PVCF40RN
PVCF60RN
PVCF90RN
PVCF45RN
PVCF70RN
PVCF100RN
Other ratings/specifications:
Watts loss at rated current: PVCF35RN: 5.45W
PVCF60RN: 7.27W
PVCF100RN: 11.50W
Operating and storage temperature range: -40 to 90C
Material specifications:
Case: glass filled PES (Polyethersulfone)
Terminals: copper alloy
Terminal plating: electroless tin
Carton quantity and weight
Amp
Carton
rating
qty.
PVCF-35-60A
12
PVCF-70-100A
6
Eaton.com/bussmannseries
2-5
Solar
products
Maximize uptime and reliability using fuses designed and listed to UL 2579: Low Voltage Fuses - Fuses for Photovoltaic
Systems.
Minimize chances of equipment failure and personnel injury
when using full range fuses having the industrys fastest
response time to low-magnitude faults.
Maximize return on investment with fuses proven to
withstand harsh temperatures.
Minimize design time, operating outage time and
replacement cost with fuses qualified in excessively
changing enviromental conditions.
Simplify compatibility with readily available industry
standard Class CF holders.
Temperature derating: designed to maximize rated capacity in
elevated environmental temperatures.
Overload protection: proven to clear faults faster than the UL
requirement.
Power loss: minimal energy consumption leading to increased
efficiency.
Solar fuses
Photovoltaic CUBEFuse
Dimensions in (mm)
Fuse
amps
A
2.13
35-40
(54.10)
2.13
45-50
(54.10)
2.13
60
(54.10)
3.01
70
(76.45)
3.01
80-90
(76.45)
3.01
100
(76.45)
G
0.38
(9.65)
0.38
(9.65)
0.38
(9.65)
0.38
(9.65)
0.38
(9.65)
0.38
(9.65)
100,000
1000
F
0.63
(15.93)
0.63
(15.93)
0.63
(15.93)
0.58
(14.78)
0.58
(14.78)
0.58
(14.78)
100A
35A
40A
50A
60A
Dimensions - in (mm)
C
D
E
1.13
0.36
0.04
(28.58)
(9.10)
(1.02)
1.13
0.44
0.04
(28.58) (11.13)
(1.02)
1.13
0.44
0.04
(28.58) (11.13)
(1.02)
1.26
0.49
0.06
(32.00) (12.45)
(1.60)
1.26
0.49
0.06
(32.00) (12.45)
(1.60)
1.26
0.57
0.06
(32.00) (14.48)
(1.60)
B
1.00
(25.40)
1.00
(25.40)
1.00
(25.40)
1.00
(25.40)
1.00
(25.40)
1.00
(25.40)
100
100A
60A
50A
40A
35A
10,000
1,000
300,000
100,000
10,000
1,000
100
10
100
TIME IN SECONDS
CUBEFuse holders
1
Catalog numbers
(amps)
Non-indicating
PVCF35RN
PVCF40RN
PVCF45RN
PVCF50RN
PVCF60RN
PVCF70RN
PVCF80RN
PVCF90RN
PVCF100RN
10,000
CURRENT IN AMPS
1,000
100
10
0.01
0.1
2-6
Eaton.com/bussmannseries
Solar fuses
Time-current
characteristic curvesaverage melt
T
100A 200A 400A
60A
100
10
100,000
Current in Amps
10,000
Typical applications:
Photovoltaic systems
Inverters
Solar DC safety switches
Recombiner boxes
1,000
0.01
100
0.1
10
30A
1000
Solar
products
Specifications:
Description: A range of UL 2579 fast-acting
600Vdc Class RK5 fuses specifically designed
to protect solar power systems in extreme
ambient temperature, high cycling and low
level fault current conditions (reverse current,
multi-array fault).
Dimensions: See page 1-3 for Class RK5
dimensions.
Ratings:
Volts 600Vac to UL 248-12
600Vdc to UL 2579
Amps 20-400A
IR 200kA RMS Sym. AC
20kA DC (20-60A)
10kA DC (70-400A)
Agency information: UL Std. 248-12, Class RK5, UL Listed,
Guide JFGA, File E335324. Photovoltaic to UL 2579, CSA
Component Certified C22.2.
Time in Seconds
PVS-R-70
PVS-R-175
PVS-R-25
PVS-R-80
PVS-R-200
PVS-R-30
PVS-R-90
PVS-R-225
PVS-R-35
PVS-R-100
PVS-R-250
PVS-R-40
PVS-R-110
PVS-R-300
PVS-R-50
PVS-R-125
PVS-R-350
PVS-R-60
PVS-R-150
PVS-R-400
Eaton.com/bussmannseries
2-7
Solar fuses
Time constant:
1-3ms
PV Fuse coordination:
With thin film cells and 4, 5 and 6 crystalline silicon
cells
Agency information:
UL Listed to 2579*, Guide JFGA, File E335324
IEC 60269-6 (gPV)
CSA File 53787, Class 1422-30 (1-15A), 20-30A Pending
CCC (1-20A) (25-30A pending)
RoHS Compliant
Description:
A range 10x38mm, 1000Vdc PV fuses for the protection
and isolation of photovoltaic strings. The fuses are
specifically designed for use in PV systems with extreme
ambient temperature, high cycling and low fault current
conditions (reverse current, multi-array fault) string arrays.
Available with four mounting styles for application
flexibility.
10x38mm
Catalog symbols:
Typical applications:
1-20A*
PV-(amp)A10F (cylindrical)
PV-(amp)A10-T (bolt mounting)
PV-(amp)A10-1P (single PCB tab)
PV-(amp)A10-2P (dual PCB tab)
PV-(amp)10F-CT (in-line, crimp terminals)
25-30A** PV10M-(amp) (cylindrical)
PV10M-(amp)-CT (in-line, crimp terminals)
Combiner boxes
BPVM_
CHPV_
1A3400-09
HPV-DV-_A
Description
1000Vdc modular fuse block
with optional cover
1- and 2-pole modular fuse holders
with optional open fuse indication
PCB fuseclip
In-line fuse holder assembly
Data Sheet #
10265
Lit # 3185
2131
2157
Bolt
fixing
PV-1A10-T
PV-2A10-T
PV-3A10-T
PV-3-5A10-T
PV-4A10-T
PV-5A10-T
PV-6A10-T
PV-8A10-T
PV-10A10-T
PV-12A10-T
PV-15A10-T
PV-20A10-T
PCB fixing
single pin
PV-1A10-1P
PV-2A10-1P
PV-3A10-1P
PV-3-5A10-1P
PV-4A10-1P
PV-5A10-1P
PV-6A10-1P
PV-8A10-1P
PV-10A10-1P
PV-12A10-1P
PV-15A10-1P
PV-20A10-1P
PCB fixing
double pin
PV-1A10-2P
PV-2A10-2P
PV-3A10-2P
PV-3-5A10-2P
PV-4A10-2P
PV-5A10-2P
PV-6A10-2P
PV-8A10-2P
PV-10A10-2P
PV-12A10-2P
PV-15A10-2P
PV-20A10-2P
In-line with
crimp terminal
PV-1A10F-CT
PV-2A10F-CT
PV-3A10F-CT
PV-3-5A10F-CT
PV-4A10F-CT
PV-5A10F-CT
PV-6A10F-CT
PV-8A10F-CT
PV-10A10F-CT
PV-12A10F-CT
PV-15A10F-CT
PV-20A10F-CT
Rated
amps
1
2
3
3.5
4
5
6
8
10
12
15
20
25
30
Rated
volts
Vdc
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
Eaton.com/bussmannseries
Interrupting
rating
50kA
50kA
50kA
50kA
50kA
50kA
50kA
50kA
50kA
50kA
50kA
50kA
20kA
20kA
I2t (A2s)
PreTotal @
arcing rated volts
0.15
0.4
1.2
3.4
4
11
6.6
18
9.5
26
19
50
30
90
3
32
7
70
12
120
22
220
34
350
325
1860*
536
3360*
Watts loss
0.8In
In
0.8
1.5
0.6
1.0
0.8
1.3
0.9
1.4
1.0
1.5
1.0
1.6
1.1
1.8
1.2
2.1
1.2
2.3
1.5
2.7
1.7
2.9
2.1
3.6
1.7
2.9
1.7
3.3
Solar fuses
HPV 1000Vdc
Packaging
Bulk packed in cartons, 180 fuse assemblies per carton. Carton
weight 19.3 Lbs (8.7543kg).
Fuse assemblies poly bagged with PV fuse element, two
insulating boots (for lineside and loadside), and one pressure
sensitive label to be applied on outside after complete assembly
to the wire harness.
Amps
Description:
HPV-DV-1A
PV-1A10F-CT
HPV-DV-2A
PV-2A10F-CT
HPV-DV-2.5A
PV-2.5A10F-CT
HPV-DV-3A
PV-3A10F-CT
Ratings
2.5
3
HPV-DV-3.5A
PV-3.5A10F-CT
Volts
1000Vdc
HPV-DV-4A
PV-4A10F-CT
Amps
1-20A
HPV-DV-5A
PV-5A10F-CT
IR
33kA
HPV-DV-6A
PV-6A10F-CT
HPV-DV-8A
PV-8A10F-CT
HPV-DV-10A
PV-10A10F-CT
10
HPV-DV-12A
PV-12A10F-CT
12
HPV-DV-15A
PV-15A10F-CT
15
HPV-DV-20A
PV-20A10F-CT
20
Agency information
Conductors
Solar
products
HPV-DV-(amp)A
HPV catalog
number
Catalog symbol:
3.5
For fuse specifications and derating curves see data sheet no. 10121 at
www.cooperbussmann.com/DatasheetsEle.
Recommended tools
Terminals
Boot material
-40C to +90C
1007July 2015
Eaton.com/bussmannseries
2-9
Solar fuses
Typical applications:
Combiner boxes
Inverters
Description:
A range of 14x51mm PV fuses specifically designed for
protecting and isolating photovoltaic strings. These fuses
are capable of interrupting low overcurrents associated
with faulted PV systems (reverse current, multi-array
fault).
Dimensions - mm
Ratings:
Volts
Amps
IR
Agency information:
UL Listed, Guide JFGA, File E335324. Photovoltaic to
UL 2579
Rated
amps
15
20
25
32
Rated
volts DC
1100
1100
1000
1000
I2t (A2s)
PreTotal @
arcing rated volts
14
265
27
568
65
943
120
1740
Watts loss
0.8In
In
2.1
4
2.7
5
2.7
5.1
3.3
6.2
1007July 2015
Eaton.com/bussmannseries
Solar fuses
NH photovoltaic fuses
Solar
products
Description:
Typical applications:
Recombiner boxes
Inverters
Ratings:
Fuse size
NH1
NH2
NH3
Volts 1000Vdc
Amps 32-400A
IR
50kA
Fuse block
SD1-D-PV
SD2-D-PV
SD3-D-PV
Agency information:
Optional microswitches*:
Part
number
170H0236
170H0238
BVL50
Tab size/
mm (inch)
250/6.3 (14)
110/2.8 (0.11)
187/4.8 (316)
Connection
Quick connect
Quick connect
Quick connect
Volts
250
250
250
Amps
2
2
6
Energy integrals
I2t (A2S)
Current
rating
(amps) Prearcing
Total at
1000V
Watts loss
Fuse
size
Current
rating
(amps)
NH1
63
Energintegrals
Energy
I2tI2(A2S)
Watts loss
Prearcing
Total at
1000V
0.8In
In
470
4300
12
0.8In
In
Part number
with bolt holes
PV-32ANH1
NH1
32
80
720
PV-63ANH1-B
PV-40ANH1
NH1
40
185
1670
PV-80ANH1-B
NH1
80
640
5760
15
PV-50ANH1
NH1
50
400
3600
11
PV-100ANH1-B
NH1
100
1300
11,700
16
PV-63ANH1
NH1
63
470
4300
12
PV-125ANH1-B
NH1
125
2600
23,400
17
PV-80ANH1
NH1
80
640
5760
15
PV-160ANH1-B
NH1
160
5200
46,800
14
27
PV-100ANH1
NH1
100
1300
11,700
16
PV-200ANH1-B
NH1
200
10,200
82,000
13
25
PV-125ANH1
NH1
125
2600
23,400
17
PV-250ANH2-B
NH2
250
17,000
136,000
19
38
PV-160ANH1
NH1
160
5200
46,800
14
27
PV-315ANH3-B
NH3
315
32,000
260,000
26
44
PV-200ANH1
NH1
200
10,200
82,000
13
25
PV-355ANH3-B
NH3
355
38,000
310,000
29
48
PV-250ANH2
NH2
250
17,000
136,000
19
38
PV-400ANH3-B
NH3
400
61,000
490,000
32
50
PV-300ANH3
NH3
300
32,000
260,000
24
40
PV-315ANH3
NH3
315
32,000
260,000
26
44
PV-350ANH3
NH3
350
44,500
370,000
27
45
PV-355ANH3
NH3
355
44,500
370,000
28
46
PV-400ANH3
NH3
400
67,500
550,000
30
50
Part number
1007July 2015
Eaton.com/bussmannseries
2-11
Solar fuses
Typical applications:
Recombiner boxes
Inverters
Fuse size
01XL
1XL
2XL
3L
Part number
SB1XL-S
SB1XL-S
SB2XL-S
SB3L-S
Description
1-pole block
1-pole block
1-pole block
1-pole block
Optional microswitches:
Blade 170H0235 or 170H0237 for size 01XL
170H0236 or 170H0238 for sizes 1XL, 2XL and 3L
Bolt-in 170H0069 for all sizes
Catalog symbols:
Blade PV-(amp)A(size)XL
Bolt-In PV-(amp)A(size)XL-B
Agency information:
01
Bladed version
PV-63A-01XL
PV-80A-01XL
PV-100A-01XL
PV-125A-01XL
PV-160A-01XL
PV-200A-1XL
PV-160A-2XL
PV-200A-2XL
PV-250A-2XL
PV-315A-2XL
PV-350A-2XL
PV-355A-2XL
PV-350A-3L
PV-400A-3L
PV-500A-3L
PV-600A-3L
PV-630A-3L*
Bolted version
PV-63A-01XL-B
PV-80A-01XL-B
PV-100A-01XL-B
PV-125A-01XL-B
PV-160A-01XL-B
PV-200A-1XL-B
PV-160A-2XL-B
PV-200A-2XL-B
PV-250A-2XL-B
PV-315A-2XL-B
PV-350A-2XL-B
PV-355A-2XL-B
PV-350A-3L-B
PV-400A-3L-B
PV-500A-3L-B
PV-600A-3L-B
PV-630A-3L-B*
Rated
amps
63
80
100
125
160
200
160
200
250
315
350
355
350
400
500
600
630*
Rated
volts
Vdc
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
I2t (A2s)
Interrupting
rating
50kA
50kA
50kA
50kA
50kA
33kA
33kA
33kA
33kA
33kA
33kA
33kA
50kA
50kA
50kA
50kA
50kA
1007July 2015
Eaton.com/bussmannseries
Pre-arcing
260
490
870
1930
3900
9400
2780
4950
9450
16,600
26,000
26,000
31,000
44,500
85,000
137,000
137,000
Total @
rated volts
1900
3600
6300
13,900
28,100
27,260
21,000
37,000
70,000
123,000
192,000
192,000
161,200
231,400
442,000
712,400
712,400
Watts loss
0.8In
In
13
24
17
29
18
32
20
40
22
44
31
60
25
44
28
50
34
60
40
66
42
68
42
68
40
65
48
82
50
85
80
108
92
118
Solar fuses
1000Vdc XL photovoltaic fuses for solar applications
3L blade size
3L bolt size
Solar
products
1007July 2015
Eaton.com/bussmannseries
2-13
Solar fuses
10000
200A
1000
160A
125A
100A
80A
100
63A
10
0.1
0.01
10
100
1000
1000
1007July 2015
Eaton.com/bussmannseries
Solar fuses
Description:
A range of 14 x 65mm package PV fuses specifically
designed for protecting and isolating photovoltaic strings.
These fuse links are capable of interrupting low
overcurrents associated with faulted PV systems (reverse
current, multi-array fault).
Available in four mounting styles for application
flexibility.
Typical applications:
Combiner boxes Inverters PV wire harnesses
Dimensions/configurations - mm:
66.70
+0.6
-2.0
10.10
14x65mm
Cylindrical PV-(amp)A14LF
90.07 / 88.07
15.22
15.02
77.12 / 75.12
69.34 / 67.34
4.70
(cylindrical)
(cylindrical with tags)
(cylindrical with 10mm fixings)
(in-line with crimp terminals)
10.99
PV-(amp)A14LF
PV-(amp)A14L-T
PV-(amp)A14LF10F
PV-(amp)A-CT__
14.30
14.10
Agency information:
14.22
14.02
86.77 / 84.77
10.25
10.05
CCC pending
118
14
RoHS compliant
* Crimp terminal version is UL Recognized to UL 2579.
Cylindrical with
10mm fixings
PV-2.25A14LF10F
PV-2.5A14LF10F
PV-3A14LF10F
PV-3.5A14LF10F
PV-4A14LF10F
PV-15A14LF10F
PV-20A14LF10F
PV-25A14LF10F
PV-32A14LF10F
In-line with
crimp terminals
PV-2.25A-CT
PV-2.5A-CT
PV-3A-CT
PV-3.5A-CT
PV-4A-CT
PV-15A-CT
PV-20A-CT
Rated
amps
2.25
2.5
3.0
3.5
4.0
15
20
25
32
Rated
volts
Vdc
1500
1500
1500
1500
1500
1500
1500
1300
1300
Interrupting
rating
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
I2t (A2s)
Total at
Pre-arcing rated voltage
4
8
5
10
8
14
12
23
18
34
14
160
34
400
65
550
105
900
Watts loss
0.8 In
In
1.4
2.3
1.5
2.5
1.7
2.8
1.8
3.0
2.0
3.3
3.2
5.8
3.6
6.5
4.1
7.5
5.7
10.4
1007July 2015
Eaton.com/bussmannseries
2-15
Solar
products
Solar fuses
Agency information:
UL Listed, Guide JFGA, File E335324.
Photovoltaic to UL 2579
IEC 60269-6 gPV
CSA Class 1422-30, File 53787
RoHS compliant
Description:
Typical applications:
Recombiner boxes
Catalog symbols:
Blade PV-(amp)A(size)XL-15
Bolt-In PV-(amp)A(size)XL-B-15
Inverters
Part number
SB1XL-S
SB1XL-S
SB2XL-S
SB3L-S
Description
1-pole block
1-pole block
1-pole block
1-pole block
Optional microswitches:
Blade 170H0235 or 170H0237 for size 01XL
170H0236 or 170H0238 for sizes 1XL, 2XL & 3L
Bolt-in 170H0069 for all sizes
01
Bladed version
PV-50A-01XL-15
PV-63A-01XL-15
PV-80A-01XL-15
PV-100A-01XL-15
PV-125A-01XL-15
PV-160A-01XL-12
PV-100A-1XL-15
PV-125A-1XL-15
PV-160A-1XL-15
PV-200A-1XL-15
PV-125A-2XL-15
PV-160A-2XL-15
PV-200A-2XL-15
PV-250A-2XL-15
PV-250A-3L-15
PV-315A-3L-15
PV-355A-3L-15
PV-400A-3L-15
Bolted version
PV-50A-01XL-B-15
PV-63A-01XL-B-15
PV-80A-01XL-B-15
PV-100A-01XL-B-15
PV-125A-01XL-B-15
PV-160A-01XL-B-12
PV-100A-1XL-B-15
PV-125A-1XL-B-15
PV-160A-1XL-B-15
PV-200A-1XL-B-15
PV-125A-2XL-B-15
PV-160A-2XL-B-15
PV-200A-2XL-B-15
PV-250A-2XL-B-15
PV-250A-3L-B-15
PV-315A-3L-B-15
PV-355A-3L-B-15
PV-400A-3L-B-15
Rated
amps
50
63
80
100
125
160
100
125
160
200
125
160
200
250
250
315
355
400
Rated
volts
Vdc
1500
1500
1500
1500
1500
1200
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
I2t (A2s)
Interrupting
rating
30kA
30kA
30kA
30kA
30kA
30kA
30kA
30kA
30kA
30kA
30kA
30kA
30kA
30kA
30kA
30kA
30kA
30kA
1007July 2015
Eaton.com/bussmannseries
Pre-arcing
75
362
565
1100
2200
5000
1250
1950
4200
9400
2200
5000
8800
16,600
22,300
38,000
44,500
58,000
Total @
rated volts
1000
2250
3300
6600
10,500
24,000
6000
9360
20,160
45,120
15,000
32,000
51,000
85,000
92,000
160,000
184,000
240,000
Watts loss
0.8In
In
14
25
15
26
19
35
22
40
23
42
26
52
24
43
25
52
30
58
31
61
25
44
29
48
32
57
40
70
32
50
36
66
44
80
49
91
Solar fuses
1500Vdc XL photovoltaic fuses
3L blade size
3L bolt size
Solar
products
1007July 2015
Eaton.com/bussmannseries
2-17
Solar fuses
1500Vdc XL photovoltaic fuses
1007July 2015
Eaton.com/bussmannseries
Contents
Description
Page
3-2
Low voltage
supplementary
fuses
1007July 2015
Eaton.com/bussmannseries
3-1
Limiters
Catalog number
Volts
K.........................
UH . . . . . . . . . . . . . . . . . . . . . . . .
68000 . . . . . . . . . . . . . . . . . . . . .
64000 . . . . . . . . . . . . . . . . . . . . .
ANN fast-acting limiter . . . . . . . . .
ANL time-delay limiter . . . . . . . . .
600V . . . . . . . . . . . . . . . . . . . . . 3-4
250V . . . . . . . . . . . . . . . . . . . . . 3-4
600V . . . . . . . . . . . . . . . . . . . . . 3-4
600V . . . . . . . . . . . . . . . . . . . . . 3-4
125Vac/80Vdc . . . . . . . . . . . . . 3-10
80Vdc . . . . . . . . . . . . . . . . . . . 3-10
Page
CH
Modular
Type
Safety J
Holders
HM250
JM600
HM600
Modular knifeblade
BH
Volts
BAF . . . . . . . . . . . . . . . . . . . . . . .
KTK . . . . . . . . . . . . . . . . . . . . . . .
KLM . . . . . . . . . . . . . . . . . . . . . . .
FNM . . . . . . . . . . . . . . . . . . . . . .
FNQ . . . . . . . . . . . . . . . . . . . . . . .
250V . . . . . . . . . . . . . . . . . . . . . 3-5
600V . . . . . . . . . . . . . . . . . . . . . 3-5
600Vac/dc . . . . . . . . . . . . . . . . . 3-6
250V . . . . . . . . . . . . . . . . . . . . . 3-7
500V . . . . . . . . . . . . . . . . . . . . . 3-7
Page
Holders
OPM-NG-SC3
OPM-1038R and
OPM-1038RSW
HPG
CH
HPM
HPC-D
HPS
HEB
HPF
Blocks
BCM panel/DIN-Rail with adapters . . . . . . . . . . . . . . . . . . . . . . . . . . .9-32
4421 and 4515 single-pole fuse blocks . . . . . . . . . . . . . . . . . . . . . . .9-57
HEX and
HEY
3-2
NDNF1-WH
Eaton.com/bussmannseries
BCM
CCP
Class CC
Volts
BBS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600V . . . . . . . . . . . . . . .
Page
3-8
Holder
HPS-L panel mount holder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-53
Blocks
BCM panel/DIN-Rail with adapters . . . . . . . . . . . . . . . . . . . . . . . . . . 9-32
4421 and 4515 single-pole fuse blocks . . . . . . . . . . . . . . . . . . . . . . 9-57
BCM
HPS-L
Volts
125V . . . . . . . . . . . . . . . 3-8
125V . . . . . . . . . . . . . . . 3-8
250V . . . . . . . . . . . . . . . 3-9
250V . . . . . . . . . . . . . . . 3-9
600V . . . . . . . . . . . . . . . 3-10
KAZ 13/32" X 2* . . . . . . . . . . . . . . . . . . .
*Not a fuse. Pin actuator only.
600V . . . . . . . . . . . . . . . 3-10
Low voltage
supplementary
fuses
HLD
Holders
1/4" X 1/4": HLD panel mount visual indication . . . . . . . . . . . . . . . . 9-52
1/4" X 1/4": HK panel mount lamp indicating. . . . . . . . . . . . . . . . . . . 9-52
HK
Blocks
1/4" X 1 1/4": 8000 for visual indication . . . . . . . . . . . . . . . . . . . . . 9-55
13/32" X 1 1/2": 4-pole signal block cat. # 3839
(not shown in catalog)*
13/32" X 2: 1-pole signal block cat. # 2778
(not shown in catalog)*
13/32" X 2: 2-pole signal block cat. # 2837
(not shown in catalog)*
13/32" X 2: 3-pole signal block cat. # 2838
(not shown in catalog)*
8000
Volts
ATC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ATM . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MAX . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
32Vdc . . . . . . . . . . . . . . 3-13
32Vdc . . . . . . . . . . . . . . 3-13
32Vdc . . . . . . . . . . . . . . 3-14
Page
Holders
ATC: HHC, HHD, HHF, HHG and ATC-FHID In-line holders . . . . . . . . 3-13
ATM: HHL, HHM and ATM-FHID In-line holders . . . . . . . . . . . . . . . . 3-14
MAX: HHX, MAX-FHID In-line holders . . . . . . . . . . . . . . . . . . . . . . . 3-14
easy ID
illuminating holders
HHL and
HHM
HHX
Volts
300V . . . . . . . . . . . . . . .
300V . . . . . . . . . . . . . . .
300V . . . . . . . . . . . . . . .
300V . . . . . . . . . . . . . . .
300V . . . . . . . . . . . . . . .
Page
3-11
3-11
3-12
3-12
3-12
Holders
GLQ and GMQ: HLQ rejection holder . . . . . . . . . . . . . . . . . . . . . . . . 3-11
GLR, GMF and GRF: HLR and HLR-2A non-rejection holders . . . . . . . 3-12
Eaton.com/bussmannseries
K 600V
UH 250V
Specifications:
Description: Cable limiters.
Ratings:
Volts 600Vac
IR 200kA RMS Sym.
@ 600Vac
Agency information: UL
Listing: KDM, KDR, KDP and
KFM, KCM, KCM-B and KCR.
Specifications:
Description: Cable limiters.
Ratings:
Volts up to 250Vac
IR 100kA RMS Sym.
Terminals:
Center bolt-to-offset bolt copper or aluminum conductors.
Conductors:
Copper or aluminum conductors are permitted per the listed
cable size. Select the catalog symbol for the system
conductor size. See data sheet 1042 for dimensions.
Cable
size
Catalog
number
Cable
size
*Tubular terminals
Typical applications:
Designed specifically for use in residental applications.
Catalog numbers
Center bolt-type terminal and off-set bolt-type terminal
Catalog
number
Copper cable
size
Aluminum cable
size
UHA
2/0AWG
4/0AWG
UHJ-M
3/0AWG
250kcmil
KCY
#4
KCF
4/0
UHJ-T
350kcmil
500kcmil
KCZ
#3
KCH
250kcmil
UHJ-W
600kcmil
800kcmil
KCA
#2
KCJ1, 2
350kcmil
KCB
#1
KCM1, 2,
KCC
1/0
KCV
KCD1, 2
2/0
KCR1,
KCE
3/0
KCS
500kcmil
600kcmil
750kcmil
1000kcmil
Specifications:
Description: Welder limiters.
Ratings:
Volts 600Vac (or less)
IR 200kA RMS Sym.
#12
KDD
2/0
KQT
#10
KDE
3/0
KFZ
#8
KDF
4/0
KIG
#6
KDH
250kcmil
KDY
#4
KDJ3
350kcmil
KDA
#2
KDM1,3
500kcmil
KDB
#1
KDU
600kcmil
KDC
1/0
KDR1,2
750kcmil
4/0
KQO
350kcmil
250kcmil
KDT
500kcmil
4/0
KDP1
500kcmil
KFT
250kcmil
KFM1
750kcmil
KEW
350kcmil
*Copper conductors only.
**Copper or aluminum conductors.
1
UL Listed (File E90818), 600Vac, 200k A I.R..
2
Available with shrink tube _V suffix.
3
Available with molded rubber boots. Boot can be purchased separately, order Part# - BOOT-KCM.
Accessories
Boots can be purchased separately.
For KCM BOOT-KCM
Nominal
amp rating
300
68600
Class H
600
64200
Class J
200
64300
Class J
300
Eaton.com/bussmannseries
BAF
KTK
Description:
Description:
Ratings:
Ratings:
Interrupting rating
at system voltage
Agency
information
250
Vac
125
Vac
UL
CSA
1/4 to 1
35A
10kA
1-1/2 to 2-1/2
100A
10kA
100A
10kA
4 to 10
200A
10kA
12 to 15
750A
10kA
20 to 30
200A
10kA
Interrupting rating
at rated voltage
1/10 to 30
Agency
information
600Vac
UL
CSA
100kA
X
Low voltage
supplementary
fuses
Fuse amp
range
Fuse
amp
range
Agency information:
Agency information:
Catalog numbers (amps)
CE
KTK-1/10
KTK-3/4
KTK-4
KTK-12
KTK-1/8
KTK-1
KTK-5
KTK-15
KTK-2/10
KTK-1-1/4
KTK-6
KTK-20
KTK-1/4
KTK-1-1/2
KTK-7
KTK-25
KTK-3/10
KTK-2
KTK-7-1/2
KTK-30
KTK-2-1/2
KTK-8
BAF-1-810 BAF-6
BAF-12
KTK-4/10
BAF-12
BAF-2
BAF-15
KTK-1/2
KTK-3
KTK-9
KTK-3-1/2
KTK-10
BAF-6-14
BAF-610
BAF-2-12
BAF-7
BAF-20
KTK-6/10
BAF-810
BAF-3
BAF-8
BAF-25
Features:
BAF-1
BAF-4
BAF-9
BAF-30
BAF-1-12
BAF-5
BAF-10
C
Features:
Typical applications:
Meter circuits
Typical applications:
Control circuits
Meter circuits
R
For superior electrical protection, Eaton recommends upgrading BAF fuse
applications to Bussmann series Low-Peak LP-CC fuses See page 1-7.
Eaton.com/bussmannseries
3-5
KLM
Description:
Fast-acting supplemental fuse.
For superior protection, Eaton recommends
upgrading to Bussmann series Low-Peak Class
CC fuses. See data sheet # 1023.
For protecting DC photovoltaic systems, Eaton
recommends using Bussmann series PVM
10x30mm PV fuses. See data sheet # 10121.
Ratings:
Interrupting rating
at rated voltage
Fuse
amp
range
1/10 to 30
Agency
information
600
Vac
600
Vdc
UL
CSA
100kA
50kA
Electrical characteristics:
% of amp rating
Opening time
110%
4 Hours minimum
135%
Agency information:
KLM-1
KLM-5
KLM-15
KLM-18
KLM-1-14
KLM-6
KLM-20
KLM-210
KLM-1-12
KLM-7
KLM-25
KLM-14
KLM-2
KLM-8
KLM-30
KLM-310
KLM-2-12
KLM-9
KLM-12
KLM-3
KLM-10
KLM-34
KLM-4
KLM-12
Features:
Eaton.com/bussmannseries
FNM
FNQ
Description:
Description:
Ratings:
Ratings:
Fuse
amp
range
Interrupting rating at
system voltage
250Vac
125Vac
Fuse
amp
range
Agency
information
UL
CSA
35A
10kA
1-1/8 to 3-1/2
100A
10kA
4 to 10
200A
10kA
12 to 30
10kA
1/10 to 30
Agency
information
500Vac
UL
CSA
10kA
X
Low voltage
supplementary
fuses
1/10 to 1
Interrupting rating
at rated voltage
Agency information:
Agency information:
FNQ-1/10
FNQ-8/10
FNQ-3-2/10 FNQ-9
FNM-110
FNM-810
FNM-2-12
FNM-6-14
FNQ-1/8
FNQ-1
FNQ-3-1/2
FNM-18
FNM-1
FNM-2-810
FNM-7
FNQ-15/100
FNQ-1-1/8
FNQ-4
FNQ-12
FNM-15100
FNM-1-18
FNM-3
FNM-8
FNQ-3/16
FNQ-1-1/4
FNQ-4-1/2
FNQ-14
FNM-210
FNM-1-14
FNM-3-210
FNM-9
FNQ-2/10
FNQ-1-1/2
FNQ-5
FNQ-15
FNM-14
FNM-1-410
FNM-3-12
FNM-10
FNQ-1/4
FNM-310
FNM-1-12
FNM-4
FNM-12
FNQ-3/10
FNQ-2
FNQ-6
FNQ-25
FNM-410
FNM-1-610
FNM-4-12
FNM-15
FNM-12
FNM-1-810
FNM-5
FNM-20
FNQ-4/10
FNQ-2-1/4
FNQ-6-1/4
FNQ-30
FNM-610
FNM-2
FNM-5-610
FNM-25
FNQ-1/2
FNQ-2-1/2
FNQ-7
FNM-34
FNM-2-14
FNM-6
FNM-30
FNQ-6/10
FNQ-3
FNQ-8
Features:
Features:
Typical applications:
Typical applications:
For superior electrical protection, Eaton recommends upgrading FNM and FNQ fuse
applications to Bussmann series Low-Peak LP-CC fuses See page 1-7.
Recommended fuse blocks and fuse holders for
13
32 x 1 12 fuses See page 3-2
Data Sheet: 2028
FNQ-10
Carton quantity
Amps
Qty.
1/10 to 30
10
For superior electrical protection, Eaton recommends upgrading FNM and FNQ fuse
applications to Bussmann series Low-Peak LP-CC fuses See page 1-7.
Recommended fuse blocks and fuse holders for
13
32 x 1 12 fuses See page 3-2
Data Sheet: 1012
Eaton.com/bussmannseries
3-7
BBS
GBA
Description:
GLD
Specifications:
Class: Supplemental
Description: Fast-acting, pin indication
fuse.
Dimensions: 14 x 1 14
(6.6 x 31.7mm) 3AG.
Ratings:
Volts See Agency Info below
Amps 12-15A
IR See Agency Info below
Agency information: CE,
Std. 248-14, UL Listed, 0-5A/125Vac, 10,000 AIC,
Guide JDYX, File E19180, UL Recognized,
6A/125Vac, 1000AIC 8-15A/50Vac/dc, 300 AIC
Guide JDYX2, File E19180, CSA Certified: 05A/125Vac, 10,000 AIC Class 1422-01, File 53787.
BBS
Ratings:
Fuse
amp
range
Interrupting rating at
system voltage
Agency
information
600
Vac
250
Vac
48
Vac
UL
CSA
10kA
7 to 10
10kA
12 to 30*
1/10 to 6
600Vac
1/10 to 6A
Agency information:
CE
250Vac
7 to 10A
BBS-8/10
BBS-4
BBS-15
BBS-2/10
BBS-1
BBS-5
BBS-20
BBS-1/4
BBS-1-1/2
BBS-6
BBS-4/10
BBS-1-6/10
BBS-7
BBS-1/2
BBS-1-8/10
BBS-8
BBS-6/10
BBS-2
BBS-10
BBS-3/4
BBS-3
BBS-12
Typical applications:
Control circuits
Electronic circuits
GLD catalog numbers (amps)
GLD-12
GLD-2
GLD-6
GLD-34
GLD-3
GLD-10
BBS-25
GLD-1
GLD-4
GLD-12
BBS-30
GLD-1-12
GLD-5
GLD-15
Features:
48Vac
12 to 30A
GBA-12
GBA-2
GBA-8
GBA-34
GBA-3
GBA-10
GBA-1
GBA-4
GBA-15
GBA-1-12
GBA-5
Typical applications:
Control circuits
Electronic circuits
Hand-held meters
HID ballasts
Page 3-3
Page 3-3
Data Sheet: 2010 (0-30A)
3-8
Pin indication
MIC
FNA
Description:
Description:
MIC
Ratings:
Interrupting rating
at voltage rating
Fuse
amp
range
UL
CSA
35A
2 to 3
100A
5 to 10
200A
15
750A
10kA
250Vac
1/10 to 6A
Ratings:
Fuse
amp
range
Interrupting rating at
system voltage
Agency
information
250
Vac
125
Vac
32
Vac
UL
CSA
1/10 to
8/10
35A
10kA
1 to 6
200A
10kA
6-1/4 to 15
10kA
20 to 30
1kA
Electrical characteristics:
Dual-tube
construction
12A and up
Agency information:
Opening time
110%
Indefinitely
135%
1 hour max.
CE
Agency information:
CE
Features:
FNA-1/10
FNA-1
FNA-1/8
FNA-1-1/8
FNA-3
FNA-9
FNA-3-2/10
FNA-10
FNA-15/100 FNA-1-1/4
FNA-3-1/2
FNA-12
FNA-2/10
FNA-1-4/10
FNA-4
FNA-15
FNA-1/4
FNA-1-1/2
FNA-4-1/2
FNA-20
FNA-3/10
FNA-1-6/10
FNA-5
FNA-25
FNA-4/10
FNA-1-8/10
FNA-5-6/10
FNA-30
FNA-1/2
FNA-2
FNA-6
FNA-6/10
FNA-2-1/4
FNA-6-1/4
FNA-3/4
FNA-2-1/2
FNA-7
FNA-8/10
FNA-2-8/10
FNA-8
Typical applications:
Control circuits
PLC Circuits
MIC-8
MIC-25
MIC-2
MIC-10
MIC-30
MIC-3
MIC-15
MIC-5
MIC-20
Features:
C
Recommended signal block for, 1332 x 1 12
indicating fuses
Page 3-3
Page 3-3
Eaton.com/bussmannseries
3-9
Low voltage
supplementary
fuses
32
Vac
% of fuse rating
Agency
information
250
Vac
20 to 30
32Vac
20 to 30A
FNA
ANN-90
ANN-225
ANN-400
ANN-35
ANN-100
ANN-250
ANN-500
ANN-40
ANN-125
ANN-275
ANN-600
ANN-50
ANN-150
ANN-300
ANN-700
ANN-60
ANN-175
ANN-325
ANN-800
ANN-80
ANN-200
ANN-350
MIS
KAZ
Specifications:
Class: Supplemental
Description: Non timedelay pin indication fuse.
Dimensions: 1332 x 2
(10.3 x 50.8mm).
Ratings:
Volts 600Vac
Amps 1-12A
IR 200kA
Features and benefits:
Type MIS has a pin
indicator providing visual
identification of failed
circuits, resulting in faster
troubleshooting (reduced
circuit downtime).
Type MIS can be used in circuits rated
600V or less.
Type MIS has an interrupting
rating of 200kA.
Typical applications:
480V control circuits
PLC circuits
Catalog numbers (amps)
MIS-1
MIS-2
MIS-3
MIS-4
MIS-5
MIS-8
MIS-10
MIS-12
Test specifications
Specifications:
Description: Non-fuse
actuator.
Dimensions: 1332 x 2
(10.3 x 50.8mm).
Ratings:
Volts 600Vac
Amps N/A
IR 200kA
Agency information:
CE, UL Listed, Guide
JDVS, File E58836.
Features and benefits:
Bussmann series signal
blocks 2778, 2837
or 2838 with KAZ
actuators mounted in parallel with
fuses having a rating of 50A or larger
to provide blown fuse dropout of
shunt-trip fused switches.
Type KAZ can be used in circuits rated
600V or less.
Type KAZ has an interrupting rating of
200kA.
Typical applications:
Large, shunt-trip fused switches
Fuse protected circuits rated 50A or
larger with shunt-trip devices.
Catalog number: KAZ
Fuse
Load
Opening time
All
110%
4 hrs. (min.)
1-5A
150%
6 min. (max.)
6-12A
150%
12 min. (max.)
13
Page 3-3
Page 3-3
ANL-125
ANL-130
ANL-150
ANL-175
ANL-200
ANL-225
ANL-250
ANL-275
ANL-300
ANL-325
ANL-350
ANL-400
ANL-500
ANL-600
ANL-675
ANL-750
Specifications
Description: Limiter fuse blocks for ANL
and ANN.
4164 furnished with nylon inserted locknuts
4164-FR furnished with standard hex nuts
Dimensions: Length: 3.38
Width: 0.95
Height: 1.62
Studs center to center: 2.43
Ratings:
Volts 125Vac
80Vdc
32Vdc (self certified)
Amps 10-800A
Poles: 1 - stud terminal
Eaton.com/bussmannseries
GLQ
GMQ
Specifications:
Class: Supplemental
Description: Fast-acting,
size-rejecting in-line fuse.
Construction: Glass tube.
Ratings:
Volts 300Vac (or less)
Amps 1-10A
IR 10kA
Agency information: CE, UL Listed Std. 248-14, (Guide
JDYX, File E19180), CSA Certified C22.2 No. 248.14,
(Class 1422-01,File 53787).
Description: Time-delay,
size-rejecting in-line fuse.
Construction: Ceramic tube.
Ratings:
Volts 300Vac (or less)
Amps 12-614A
IR 10kA
Agency information: CE, UL Listed Std. 248-14, (Guide
JDYX, File E19180), CSA Certified, (Class 1422-01,
File 53787)
Low voltage
supplementary
fuses
Specifications:
Class: Supplemental
Typical applications:
In-line lighting ballast protection
Typical applications:
In-line lighting ballast protection
Holder1, 2
HLQ-1-61 0
HLQ-1-61 0
HLQ-1-61 0
HLQ-3 -21 0
HLQ-3 -21 0
Fuse
GLQ-3
GLQ-4
GLQ-5
GLQ-9
GLQ-10
Holder1, 2
HLQ-3 -21 0
HLQ-5
HLQ-5
HLQ-10
HLQ-10
1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235
10A, 300Vac.
2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a
keyhole punch using separate mounting clip #6374 for panels of thickness 0.043to 0.062 or #4909
for thickness 0.030 to 0.042.
Do not put tension on line (rear) terminal of fuse holder.
Holders1, 2
Fuse
Holders3, 4
GMQ-12
HLQ-12
GMQ-2-12
HLQ-3 -210
GMQ-610
HLQ-1-610
GMQ-3
HLQ-3 -210
GMQ-810
HLQ-1-610
GMQ-3 -210
HLQ-3 -210
GMQ-1
HLQ-1-610
GMQ-4
HLQ-5
GMQ-1-14
HLQ-1-610
GMQ-5
HLQ-5
GMQ-1-610
HLQ-1-610
GMQ-6 -14
HLQ-8
GMQ-2
HLQ-3 -210
1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235
10A, 300Vac.
2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a
keyhole punch using separate mounting clip #6374 for panels of thickness 0.043to 0.062 or #4909
for thickness 0.030 to 0.042
Do not put tension on line (rear) terminal of fuse holder.
HLQ
fuse holders
for both GLQ and GMQ fuses.
Eaton.com/bussmannseries
3-11
GLR
GMF
Specifications:
Class: Supplemental
Description: Fast-acting,
non-rejection, in-line fuse.
Construction: Glass tube.
Ratings:
Volts 300Vac (or less)
Amps 316-15A
IR 10kA
Agency information: CE, UL Listed Std. 248-14,
0-15A/300Vac (Guide JDYX, File E19180), CSA Certified
C22.2, No. 248-14, 0-10A/300V (Class 1422-01, File 53787).
GRF
Typical applications:
In-line lighting ballast protection
Catalog numbers (amps) and non-rejection holders
Fuse
GLR-12
GLR-1
GLR-1-12
GLR-1 -61 0
GLR-2
GLR-3
GLR-4
GLR-5
Holder1, 2*
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
Fuse
GLR-6
GLR-7
GLR-8
GLR-9
GLR-10
GLR-12
GLR-15
Holder1, 2*
HLR
HLR
HLR
HLR
HLR
HLR
HLR-2A
1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01,
File 47235 12A, 300Vac.
2) Units can be panel-mounted either in a knockout hole with a separate steel clip
(BK/A-104) or in a keyhole punch using separate mounting clip #6374 for panels of
thickness 0.043to 0.062 or #4909 for thickness 0.030 to 0.042.
* For two leads (one each for line and loadside) order HLR-2A,
15A, 300V
Specifications:
Class: Supplemental
Description: Time-delay,
non-rejection, in-line fuse.
Construction: Glass tube.
Ratings:
Volts 300Vac (or less)
Amps 310-10A
IR 10kA
Agency information: CE, UL Listed Std. 248-14 0-10A,
(Guide JDYX, File E19180), CSA Certified, (Class 1422-01, File
53787).
An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comes
WITHOUT leads. The customer inserts #18 insulated solid copper wire into the line side
receptacle as well as into the load side receptacle. It has the same body dimensions,
utilizes the same mounting hole, and takes the same mounting clips as the HLR. The A
fuse holder is UL Recognized, 10A, 300Vac, Guide IZLT2, File E14853 and CSA
Certified, 10A, 300Vac, Class 6225-01, File 47235.
Do not put tension on line (rear) terminal of fuse holder.
Typical applications:
In-line lighting ballast protection
Catalog numbers (amps) and non-rejection holders
Fuse
GMF-31 0
GMF-12
GMF-61 0
GMF-81 0
GMF-1
GMF-1-14
GMF-1-61 0
GMF-2
GMF-2 -12
GMF-2 -81 0
3-12
Holder1, 2*
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comes WITHOUT leads.
The customer inserts #18 insulated solid copper wire into the line side receptacle as well as into the
load side receptacle. It has the same body dimensions, utilizes the same mounting hole, and takes
the same mounting clips as the HLR. The A fuse holder is UL Recognized, 10A, 300Vac, Guide
IZLT2, File E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235.
Do not put tension on line (rear) terminal of fuse holder.
HLR-2A
Fuse
GMF-3
GMF-3 -21 0
GMF-4
GMF-5
GMF-6 -14
GMF-7
GRF-8
GMF-10
GRF-10
1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235
12A, 300Vac.
2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a
keyhole punch using separate mounting clip #6374 for panels of thickness 0.043to 0.062 or #4909
for thickness 0.030 to 0.042.
Holder1, 2*
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
fuse holder
HLR
fuse holder
Eaton.com/bussmannseries
ATC fuse
(actual size)
Available
with
indication
Available
with
indication
ATM
(actual size)
LED indicator
Specifications:
Description: In-line fuse holders for
ATC blade-type fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 32Vdc
Amps: 80% continuous of fuse
rating. See catalog numbers
table for individual fuses sizes.
Catalog numbers
Fuse holder
description
Black w/ cover
Fuse
amps
1-40
1-20
1-30
1-20
1-30
1-30
1-20
Electrical
connection
#16 red leadwire
#16 black leadwire
#12 yellow leadwire
#16 yellow leadwire
#12 yellow leadwire
#12 red leadwire
#18 to 14 black leadwire
1-20
ATM-LP
Specifications:
Description: Fast-acting blade fuse.
Construction: Colored plastic housing
with zinc fuse element.
Ratings:
Volts 32Vdc
Amps 1-30A
IR 1000A
Agency information: UL Listed Guide
FHXT, File AU 169 (2-30A non-indicating
ATM).
Features and benefits:
Color coded plastic housing for easy
identification of fuse ratings
Typical applications:
Automotive
Non-indicating
*Indicating
Color
ATC-1
Black
Catalog
numbers
HHA
HHC
HHD
HHF
HHG
HHR
HHS
ATC-2
Gray
ATC-FHID
ATM-4
ATC-3
ATC-3ID
Violet
ATM-5
ATM-5ID
ATM-5LP
Tan
ATM-7-1/2
ATM-7-1/2ID
ATM-7-1/2LP
Brown
ATM-10
ATM-10ID
ATM-10LP
Red
ATM-15
ATM-15ID
ATM-15LP
Blue
ATM-20
ATM-20ID
ATM-20LP
Yellow
ATM-25
ATM-25ID
ATM-25LP
Clear
ATC-4
Pink
ATC-5
ATC-5ID
Tan
ATC-7-1/2
ATC-7-1/2ID
Brown
ATC-10
ATC-10ID
Red
ATC-15
ATC-15ID
Blue
ATC-20
ATC-20ID
Yellow
ATC-25
ATC-25ID
Clear
ATC-30
ATC-30ID
Green
ATC-35
ATC-35ID
Blue-Green
ATC-40
ATC-40ID
Orange
Yellow
Black
Black w/ cover
Black w/ cover
Black w/ cover
Blue w/ cover
Indicating holder
Black w/ cover
*Indicating
Low-profile
Color
ATM-1
Black
ATM-2
Gray
ATM-3
ATM-3ID
Violet
Pink
ATM-30
ATM-30ID
ATM-30LP
*Call Eaton customer satisfaction for ordering information.
Green
0.91"
0.38" 0.30"
0.5"
0.25"
4.0" + 0.25"
0.364"
Non-indicating
1.125"
4.0" + 0.25"
Eaton.com/bussmannseries
3-13
Low voltage
supplementary
fuses
Specifications:
Description: Fast-acting
blade fuse.
Construction: Colored plastic
housing with zinc fuse element.
Ratings:
Volts 32Vdc
Amps 1-40A
IR 1000A
Agency information: UL
Recognized, (1-40A) (Guide
JFHR2, File E56412), SAE Standard
J1284.
ATM fuse
HHX, MAX-FHID
MAX Maxifuse
Available
with
indication
(actual size)
LED indicator
Specifications:
Description: In-line fuse holders for
ATM Fuses.
Ratings:
Volts: 32Vdc
Amps: 80% continuous of fuse
rating. See catalog numbers
table for individual fuses sizes.
Catalog numbers
Catalog Fuse holder
numbers description
HHH
Black w/ cover
Fuse
amps
1-30
HHL
Black w/ cover
1-20
HHLP
Black w/ cover
1-30
HHM
Black w/ cover
1-30
HHU
Black w/ cover
1-30
Indicating holder
ATM-FHID
1-20
Black w/ cover
Electrical
connection
#16 black leadwire,
5 length
#16 black leadwire,
4 length stripped to 1/4
#16 black leadwire,
5 length
#12 red leadwire,
4 length stripped to 1/4
#16 black leadwire,
Specifications:
Description: Fast-acting blade fuse.
Construction: Colored plastic housing
with zinc fuse element.
Ratings:
Volts 32Vdc
Amps 20-80A (non-indicating)
20-100A (indicating)
IR 1000A
Features and benefits:
Color coded plastic housing for easy
identification of fuse ratings
Typical applications:
Automotive
Specifications:
Description: In-line fuse holders for
MAXI Fuses.
Ratings:
Volts: 32Vdc
Amps: 80% continuous of fuse
rating. See catalog numbers
table for individual fuses sizes.
Catalog numbers
Catalog
numbers
HHX
MAX-FHID
Fuse holder
description
Black w/ cover
Fuse
amps
20-60
Indicator black
20-60
w/ cover
Non-indicating
*Indicating
MAX-20
MAX-20ID
Color
Yellow
MAX-25
Gray
MAX-30
MAX-30ID
Green
MAX-35
Brown
MAX-40
MAX-40ID
Orange
MAX-50
MAX-50ID
Red
MAX-60
MAX-60ID
Blue
MAX-70
MAX-70ID
Tan
MAX-80
MAX-80ID
Clear
Dimensions - in
3.35"
6.70"
4.75"
4.75"
.25"
MAX-100ID
Purple
*Call Eaton customer satisfaction for ordering information.
.59"
.41"
Page 3-15
BUSSMANN SERIES FULL LINE CATALOG 1007July 2015
6.70"
1.37"
1.56"
.25"
Electrical
connection
#6 red leadwire,
5 with blunt ends
#6 red leadwire,
Eaton.com/bussmannseries
1.90
0.075
3.96
0.156
.295"
(7.49mm)
.330"
(8.38mm)
4.98
0.196
Color
ATR-5
Tan
ATR-7-1/2
Brown
ATR-10
Red
ATR-15
Blue
ATR-20
Yellow
ATR-25
Clear
ATR-30
Green
.053"
(1.35mm)
11.18
0.440
.150"
(3.81mm)
1.57
0.062
3.18
0.125
3.66
0.144
2.18
0.086
4.47
0.176
1.65 0.05
0.065 0.002
(TYP-4)
(2.03 0.25mm)
.090"
(2.29mm)
1.57
0.062
3.66
0.144
0.08" 0.01"
.200"
(5.08mm)
Catalog
Number
Clip
Mat.*
Finish
1A5600
Cart.
Brass
Satin
Finish Tin
Low voltage
supplementary
fuses
Specifications:
Description: Fast-acting color
coded 2-leg micro blade fuse.
Construction: Colored plastic
housing with zinc fuse element.
Ratings:
Volts 32Vdc
Amps 5-30A
IR 1000A
3.66
0.144
1A5780
Dimensional data
DIA. HOLE
19.30
0.760
4.45
0.175
1A5779
3.18
0.125
BASE
6.88
0.271
14.68
0.578
FUSECLIPS
1.24
0.049
1
6.35
0.250
4.75
0.187
11.10
0.437
BASE
1.27
0.050
FUSECLIPS
5.08
0.200
8.64
0.340
2.54
0.100
1.45
0.057
3.18
0.125
4.06
0.160
2.54 0.05
0.100 0.002
(TYP-4)
5.08
0.200
DIA. HOLE
MOUNTING LAYOUT
3.66
0.144
1.57
0.062
3.66
0.144
4.47
0.176
SPECIFICATIONS
3.66
0.144
FUSECLIPS . . . . . . . .
BASE MATERIAL
1.65 0.05
0.065 0.002
(TYP-4)
DIA. HOLE
SPECIFICATIONS
BASE MATERIAL
.....
CURRENT RATING . . . . .
15 AMPS
VOLTAGE RATING . . . . .
500V AC
-50C
TEMPERATURE RATING . .
-58F
CURRENT RATING . . . . .
15 AMPS
VOLTAGE RATING . . . . .
500V AC
MOUNTING LAYOUT
FUSECLIPS . . . . . . . .
.....
TO
*Spg. Br. - spring bronze; BeCu - beryllium copper; cart. brass cartridge brass
145C
292F
Eaton.com/bussmannseries
3-15
3-16
Eaton.com/bussmannseries
Contents
Description
Page
Electronic
fuses
1007July 2015
Eaton.com/bussmannseries
4-1
C519
C520
Specifications
Description:
Time-delay fuse.
Dimensions:
5 x 15mm
(0.197 X 0.591).
Construction:
Glass tube.
Ratings:
Volts 125Vac (3.57A)
250Vac
(125mA-3A)
32Vdc (self certified)
Amps 125mA-7A
IR 25A (350mA @ 600Vac)
35A (125mA-1A @ 250Vac)
100A (1.25-3A @ 250Vac)
400A (3.5-7A @ 125Vac)
10kA (125mA-3A @ 125Vac)
Agency information: CE, UL Listed
File E19180, Guide JDYX
125mA-250mA and 375mA-3A, UL
Recognized, File E19180, Guide
JDYX2, 350mA and 3.5A-7A, CSA
Certification File 53787, Class
1422-01, 125mA-250mA and
375mA-3A.
Specifications
Description:
Fast-acting fuse.
Dimensions:
5 x 15mm
(0.197 X 0.591).
Construction:
Glass tube.
Ratings:
Volts 250Vac
32Vdc (self
certified)
Amps 100mA-5A
IR 35A (100mA-750mA @
250Vac)
10kA (100mA-5A @ 125Vac)
100A (1.5-3.5A @ 250Vac)
200A (4-5A @ 250Vac)
Agency information: CE,
UL Recognized File E19180, Guide
JDYX2CSA Certification File 53787,
Class 1422-01.
Specifications
Description: Fast-acting
fuse.
Typical applications
Electronic circuits
Printed circuit boards
Electronic ballast protection
Catalog number (amps)
With axial leads
C517-3-R
Typical applications
Electronic circuits
Printed circuit boards
Catalog numbers (amps)
C515-2.5-R
C515-3-R
C515-3.5-R
C515-4-R
C515-5-R
C515-6-R
C515-7-R
C519-2.25-R
C519-2.5-R
C519-3-R
C519-3.5-R
C519-4-R
C519-5-R
C518-4-R
C518-5-R
C520-3.5-R
C520-4-R
C520-5-R
1007July 2015
Eaton.com/bussmannseries
S500-V (GDB-V)*
(axial leads)
S500 (GDB)*
Typical applications
Electronic circuits
Catalog numbers (amps)
S500-32-R
S500-40-R
S500-50-R
S500-63-R
S500-80-R
S500-100-R
S500-125-R
S500-160-R
S500-200-R
S500-250-R
S500-315-R
S500-400-R
S500-500-R
S500-630-R
S500-800-R
S500-1-R
S500-1.25-R
S500-1.6-R
S500-2-R
S500-2.5-R
S500-3.15-R
S500-4-R
S500-5-R
S500-6.3-R
S500-8-R
S500-10-R
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
40
50
63
80
100
I2t
0.000047
0.00011
0.00020
0.00057
0.0012
0.003
0.005
0.008
0.016
0.028
0.058
0.018
0.018
0.035
0.067
0.60
0.84
1.6
4.2
6.1
13
22
42
69
-
Max voltage
drop (mV)
3200
2500
2400
2000
1200
1100
1000
2000
1700
1400
1300
1100
220
220
190
200
200
190
150
150
130
130
120
120
120
120
Options
Axial leads, put V in P/N,
*When ordering GDBversion, do not
add -R suffix to part number.
S505-V
(axial leads)
S505
Specifications
Description: Timedelay, high-breaking
capacity fuse.
Construction:
Ceramic tube, silverplated brass endcaps.
Ratings:
Volts 250Vac (or less)
32Vdc (self
certified)
Amps 500mA-12A
IR 1500A @ 250Vac
Agency information: UL, CSA,
SEMKO, VDE, BSI, IMQ, PSE/JET,
CCC, EK, FIMKO.
See data sheet for complete agency
information. Not all approvals apply
to all ratings.
Specifications
Description: Fastacting, high-breaking
capacity fuse.
Construction:
Ceramic tube,
nickel-plated brass
endcaps (silverplated endcaps 50mA-400mA).
Ratings:
Volts 250Vac (or less)
32Vdc (self certified)
Amps 50mA-10A**
IR 1500A @ 250Vac
Agency information: CE, cURus,
SEMKO, VDE, IMQ, CCC, CSA, BSI.
See data sheet for complete agency information. Not all approvals apply to all ratings.
Features and benefits
Fast-acting for maximum protection.
High break capacity for use in higher
fault energy electronic circuitry.
Conforming to IEC standards.
Typical applications
Electronic circuits
Catalog numbers (amps)
Typical applications
Electronic circuits
Catalog numbers (amps)
Catalog
numbers
S501-50-R
S501-63-R
S501-80-R
S501-100-R
S501-125-R
S501-160-R
S501-200-R
S501-250-R
S501-315-R
S501-400-R
S501-500-R
S501-630-R
S501-800-R
S501-1-R
S501-1.25-R
S501-1.6-R
S501-2-R
S501-2.5-R
S501-3.15-R
S501-4-R
S501-5-R
S501-6.3-R
S501-8-R
S501-10-R
I2t
Typical voltage
drop (mV)
0.0017
0.0005
0.0011
0.0018
0.0037
0.008
0.020
0.027
0.010
0.018
0.038
0.064
0.097
0.146
0.313
0.748
2.0
3.9
8.1
14
25
48
N/A
N/A
9000
3300
2600
2300
1900
1600
1350
1300
1400
1200
1050
1200
490
330
297
239
205
190
160
160
155
150
N/A
N/A
Catalog
numbers
Typical
I2t
Max voltage
drop (mV)
S505-500-R
0.188*
295
S505-800-R
0.632*
189
S505-1-R
1.28
152.5
S505-1.25-R
2.22
150
S505-1.6-R
6.78
125
S505-2-R
9.60
118.5
S505-2.5-R
16.60
115
S505-3.15-R
36.60
102.5
S505-4-R
38.45*
86.5
S505-5-R
71.30*
77.5
S505-6.3-R
197
75
S505-8-R
311
75
S505-10-R
397
72
S505-12-R
713.7*
77
*The typical I2t value was measured at 10 times of rated
current under DC.
Options
Options
Axial leads, put V in P/N.
*When ordering GDAversion, do not
add -R suffix to part number.
**GDA is not available above 6.3A.
1007July 2015
4-3
Electronic
fuses
IR
(amps)
(axial leads)
S501 (GDA)*
Specifications
Description: Fastacting, low-breaking
capacity fuse.
Construction:
Glass tube, nickelplated brass endcaps
(silver-plated endcaps, 32-125mA).
Ratings:
Volts 250Vac (or less)
32Vdc (self certified)
Amps 32mA-10A
IR See catalog table
Agency information: CE, cURus,
SEMKO, VDE, BSI, IMQ, CCC.
See data sheet for complete agency
information. Not all approvals apply to all
ratings.
Catalog
numbers
S501-V (GDA-V)*
S505H (S505H-V)*
S506-V (GDC-V)*
(axial leads)
S506 (GDC)*
Specifications
Description: Timedelay, high-breaking
capacity fuse.
Construction:
Ceramic tube, nickelplated brass endcaps.
Ratings:
Volts 600Vac/400Vdc
500mA-5A
6.3A-10A
500Vac/400Vdc
Amps 500mm-10A
IR 35A @ 250Vac
Agency information: cURus, CCC,
CQC, TUV, PSE/JET.
See data sheet for complete agency
information. Not all approvals apply to all
ratings.
Specifications
Description: Timedelay, low-breaking
capacity fuse.
Construction: Glass
tube, nickel-plated
brass endcaps.
Ratings:
Volts 250Vac (or less)
32Vdc (self certified)
Amps 32mA-15A**
IR 35A @ 250Vac
Agency information: UR, CSA,
cURus, SEMKO, VDE, BSI, IMQ,
PSE/JET, CCC.
See data sheet for complete agency
information. Not all approvals apply to all
ratings.
Typical
I2t (A2s)1
0.188
0.632
1.28
2.22
6.78
11.44
24.23
43.55
38.45
71.3
111.4
228.2
349.5
295
189
153
150
125
128
126
121
90
89
80
76
72
Options
Axial leads, put V in P/N.
Max voltage
drop (mV)3
(axial leads)
Typical
I2t
S506-32-R
S506-40-R
S506-50-R
S506-63-R
S506-80-R
S506-100-R
S506-125-R
S506-160-R
S506-200-R
S506-250-R
S506-315-R
S506-400-R
S506-500-R
S506-630-R
S506-800-R
S506-1-R
S506-1.25-R
S506-1.6-R
S506-2-R
S506-2.5-R
S506-3.15-R
S506-4-R
S506-5-R
S506-6.3-R
S506-8-R
S506-10-R
S506-12.5-R
S506-15-R
0.0051
0.0072
0.0095
0.021
0.038
0.045
0.063
0.093
0.114
0.265
0.621
0.872
0.827
1.33
2.78
6.45
10.05
21.7
31.6
59.4
96.4
71.8
142.5
237.6
255.8
450
1019.5
1091.7
Max voltage
drop (mV)
1050
920
800
760
580
490
390
320
340
270
250
210
140
150
75
87.5
86
82
77
72.5
68.5
67
60.5
54
55
54
45
65.5
Options
Axial leads, put V in P/N.
*When ordering GDCversion, do not add
-R suffix to part number.
**GDC series is not available above 6.3A.
1007July 2015
Eaton.com/bussmannseries
5 x 20mm UL fuses
GMA
GMC
Specifications
Description:
Fast-acting fuse.
Dimensions:
5 x 20mm
(0.197 x 0.788).
Construction:
Glass tube,
nickel-plated brass
endcaps.
Ratings:
Volts 250Vac (63mA-2.5A)
125Vac (3.15-15A)
32Vdc (self certified)
Amps 63mA-15A
IR 35A (63mA- 1A @ 250Vac,
p.f. = 0.7-0.8)
10kA (63mA-6A @ 125Vac,
p.f. = 0.7-0.8)
100A (1.25-2.5A @ 250Vac,
p.f. = 0.7-0.8)
200A (7-8A @ 125Vac, p.f. = 1.0)
150A (10-15A @ 125Vac,
p.f. = 1.0)
Agency information: CE, Std.
248-14 ULListed Guide JDYX, File
E19180, 0-6A, UL Recognized, Guide
JDYX2, File E19180, 7-15A, CSA
Certified, Class 1422-01,File 53787, 0-6.
Specifications
Description: Medium
time-delay fuse.
Dimensions: 5 x 20mm
(0.197 x 0.788).
Construction: Glass
tube, nickel-plated brass
endcaps.
Ratings:
Volts 250Vac (63mA3.15A)
125Vac (3.5-10A)
32Vdc (self certified)
Amps 63mA-10A
IR 35A (63mA- 1A @ 250Vac,
p.f. = 0.7-0.8)
10kA (63mA-6A @ 125Vac, p.f.
= 0.7-0.8)
100A (1.25-3.15A @ 250Vac,
p.f. = 0.7-0.8)
200A (6.3-10A @ 125Vac, p.f.
= 1.0)
Agency information: CE, Std. 248-14,
ULListed Guide JDYX, File E19180,
0-6.3A, UL Recognized, Guide JDYX2,
File E19180, 7-8A, CSA Certified, Class
1422-01, File 53787, 0-6.3A.
GMC-10A
GMA-V-4-R
GMA-V-5-R
GMA-V-6-R
GMA-V-7-R
GMA-V-8-R
GMA-V-10-R
GMA-V-15-R
GMA-4-R
GMA-5-R
GMA-6-R
GMA-7-R
GMA-8-R
GMA-10-R
GMA-15-R
GMC-V-2.5-R
GMC-V-3.15-R
GMC-V-3.5-R
GMC-V-4-R
GMC-V-5-R
GMC-V-6-R
GMC-V-6.3-R
GMC-V-7-R
GMC-V-8-R
GMC-V-10-R
GMC-2.5-R
GMC-3.15-R
GMC-3.5-R
GMC-4-R
GMC-5-R
GMC-6-R
GMC-6.3-R
GMC-7-R
GMC-8-R
GMC-10-R
GMD
GMD
Specifications
Description: Timedelay fuse.
Dimensions:
5 x 20mm
(0.197 x 0.788).
Construction:
Glass tube, nickelplated brass
endcaps.
Ratings:
Volts 250Vac
32Vdc (self certified)
Amps 125mA-4A
IR 10kA (125mA-3A @ 125Vac,
p.f. = 0.7-0.8)
10kA (4A @ 125Vac,
p.f. = 1.0)
35A (125mA-1A @ 250Vac,
p.f. = 0.7-0.8)
100A (1.2A-3.A @ 250Vac,
p.f. = 0.7-0.8)
200A (4A @ 250Vac,
p.f. = 1.0)
Agency information: CE, ULListed
Guide JDYX, File E19180, 125mA-3A,
UL Recognized, Guide JDYX2, File
E19180, 4A, CSA Certified, Class
1422-01, File 53787, 0-4A, PSE/JET.
File 1641-31003-1001, 1.2A-4A.
Features and benefits
Time-delay compatibility for inductive circuits.
Conforming to UL standards.
Typical applications
Electronic circuits
Catalog numbers (amps)
With axial leads
GMD-V-125-R
GMD-V-500-R
GMD-V-150-R
GMD-V-600-R
GMD-V-200-R
GMD-V-630-R
GMD-V-250-R
GMD-V-750-R
GMD-V-300-R
GMD-V-800-R
GMD-V-315-R
GMD-V-1-R
GMD-V-375-R
GMD-V-1.2-R
GMD-V-400-R
GMD-V-1.25-R
Without axial leads
GMD-125-R
GMD-500-R
GMD-150-R
GMD-600-R
GMD-200-R
GMD-630-R
GMD-250-R
GMD-750-R
GMD-300-R
GMD-800-R
GMD-315-R
GMD-1-R
GMD-375-R
GMD-1.2-R
GMD-400-R
GMD-1.25-R
GMD-V-1.5-R
GMD-V-1.6-R
GMD-V-2-R
GMD-V-2.5-R
GMD-V-3-R
GMD-V-4-R
GMD-1.5-R
GMD-1.6-R
GMD-2-R
GMD-2.5-R
GMD-3-R
GMD-4-R
Data Sheet:2019
1007July 2015
Eaton.com/bussmannseries
4-5
Electronic
fuses
AGA
AGW
AGX
Specifications
Description: Fast-acting
fuse.
Dimensions:
1
4 x 58
(6.4 x 15.9mm).
Construction: Glass tube.
Ratings:
Volts 125Vac (or less)
32Vdc (self certified)
Amps 1-30A
IR 10kA (1-112A @ 125Vac)
200A (2-5A @ 125Vac)
1000A (6-30A @ 32Vac)
Agency information: CE, Std. 24814, UL File E19180, UL Listed, Guide
JDYX 0-312A UL Recognized, Guide
JDYX2 12-30A.
Specifications
Description: Fast-acting
fuse.
Dimensions: 14 x 78
(6.4 x 22.2mm).
Construction: Glass
tube.
Ratings:
Volts 32Vac
32Vdc (self certified)
Amps 1-30A
Specifications
Description: Fast-acting
fuse.
Dimensions: 14 x 1
(6.4 x 25.4mm).
Construction: Glass tube.
Ratings:
Volts 250Vac (116-20A)
125Vac (25-30A)
32Vdc (116-30A)
Amps 116-30A
IR 35A (116-1A @ 250Vac)
10kA (116-10A @ 125Vac)
200A (15-20A @ 125Vac)
100A (25-30A @ 125Vac)
1000A (8-30A @ 32Vac)
Agency information: cULus: AGX
0-10A (Guide JDYX, File E 19180 and
Guide JDYX7, File E19180), UL
Recognized Card: AGX 15-30A (Guide
JDYX2, File E19180), CSA Component
Acceptance Card : AGX 15-30A (Class
No. 1422-01, File 53787)
AGW-4
AGW-15
AGW-1- 12
AGW-5
AGW-20
AGW-2
AGW-6
AGW-25
AGW-2- 12
AGW-7-12
AGW-30
AGW-3
AGW-10
Typical applications
Electronic circuits
AGA-5
AGA-15
AGA-1-12
AGA-6
AGA-20
AGA-2
AGA-7
AGA-25
Typical applications
Electronic circuits
AGA-2-12
AGA-7-12
AGA-30
AGA-3
AGA-10
1007July 2015
AGX-14
AGX-1-12
AGX-310
AGX-2
AGX-10
AGX-38
AGX-2-12
AGX-15
AGX-410
AGX-3
AGX-20
AGX-12
AGX-4
AGX-25
AGX-34
AGX-5
AGX-30
AGX-1
AGX-6
AGX-1-14
AGX-7
AGX-8
Specifications
Description:
Fast-acting fuse.
Dimensions: 14 x 1 14
(6.4 x 31.7mm).
Specifications
Description: Fast-acting fuse.
Dimensions:
1
4 x 1 14 (6.4 x 31.7mm).
Specifications
Description: Very
fast-acting fuse.
Dimensions:
1
4 x 1 14
(6.4 x 31.7mm).
Construction:
Ceramic cartridge with
nickel-plated brass
endcaps.
Ratings:
Volts 250Vac/125Vdc
Amps 1-30A
IR 200A @ 250Vac
200A (20-30A @ 125Vac/dc)
10,000A (1A -15A @
125Vac/dc)
Agency information:
CE, Std. 248-14, UL Recognized,
1-30,125Vdc/250Vac, File E56412,
Guide JFHR2, CSA Accepted, 1-30,
125Vdc/250Vac, File 53787, Class
1422-30.
Construction: Glass
tube with nickel-plated
brass endcaps.
Ratings:
Volts 250Vac (120-10A)
32Vac (12-40A)
32Vdc (self certified)
Amps 120-40A
IR 35A (120-1A @ 250Vac)
100A (114-3A @ 250Vac)
200A (4-10A @ 250Vac)
10kA (120-10A @ 125Vac)
1000A (12-40A @ 32Vac)
AGC-V-1- 14-R
AGC-V-1- 12-R
AGC-V-2-R
AGC-V-2- 14-R
AGC-V-2- 12-R
AGC-V-3-R
AGC-V-4-R
AGC-V-5-R
AGC-V-6-R
AGC-V-7-R
AGC-V-7- 12-R
AGC- 20-R
AGC-110-R
AGC-18-R
AGC-316-R
AGC-210-R
AGC-14-R
AGC-310-R
AGC-38-R
AGC-12-R
AGC-34-R
AGC-1-R
AGC-1- 4-R
AGC-1- 12-R
AGC-2-R
AGC-2- 14-R
AGC-2- 12-R
AGC-3-R
AGC-4-R
AGC-5-R
AGC-6-R
AGC-7-R
AGC-7- 12-R
AGC-V-8-R
AGC-V-9-R
AGC-V-10-R
AGC-V-12-R
AGC-V-14-R
AGC-V-15-R
AGC-V-20-R
AGC-V-25-R
AGC-V-30-R
AGC-V-35-R
AGC-V-40-R
AGC-8-R
AGC-9-R
AGC-10-R
AGC-12-R
AGC-14-R
AGC-15-R
AGC-20-R
AGC-25-R
AGC-30-R
AGC-35-R
AGC-40-R
*CSA approvals for 25A and 30A are at 125Vac IR 1000A and Vdc IR 400A
(IR 1000A at 75Vdc)
**Interrupting ratings measured at 70% 80% power factor on AC. The
interrupting ratings for 18A and 20A were measured at 85%-95% power factor
on AC. The interrupting ratings for 25A and 30A were measured at 89% power
factor on AC.
Typical applications
Electronic circuits
Catalog numbers (amps)
With axial leads
GBB-V-1-R
GBB-V-1-14-R
GBB-V-2-R
GBB-V-3-R
GBB-V-4-R
GBB-V-5-R
Typical applications
Electronic circuits
Catalog numbers (amps)
With axial leads
ABC-V- 14-R
ABC-V- 12-R
ABC-V- 34-R
ABC-V-1-R
ABC-V-1- 12-R
ABC-V-2-R
ABC-V-2- 12-R
ABC-V-3-R
ABC-V-4-R
ABC-V-5-R
ABC-V-6-R
ABC-V-7-R
ABC-V-8-R
ABC-V-10-R
ABC-V-12-R
ABC-V-15-R
ABC-V-18-R
ABC-V-20-R
ABC-V-25-R
ABC-V-30-R
ABC- 14-R
ABC- 12-R
ABC- 34-R
ABC-1-R
ABC-1- 12-R
ABC-2-R
ABC-2- 12-R
ABC-3-R
ABC-4-R
ABC-5-R
ABC-6-R
ABC-7-R
ABC-8-R
ABC-10-R
ABC-12-R
ABC-15-R
ABC-18-R
ABC-20-R
ABC-25-R
ABC-30-R
GBB-V-6-R
GBB-V-7-R
GBB-V-8-R
GBB-V-9-R
GBB-V-10-R
GBB-V-12-R
GBB-V-15-R
GBB-V-20-R
GBB-V-25-R
GBB-V-30-R
GBB-15-R
GBB-20-R
GBB-25-R
GBB-30-R
Eaton.com/bussmannseries
4-7
Electronic
fuses
MDL-V (axial
leads)
MDL
Specifications
Description:
Time-delay fuse.
Dimensions: 14 x 1 14
(6.4 x 31.7mm).
Construction:
Glasstube with nickel-plated brass endcaps.
Ratings:
Volts 250Vac (116-8A)
32Vac (9-30A)
32Vdc (Self Certified)
Amps 116-30A
IR* 35A (116-1A @ 250Vac)
100A (114-3A @ 250Vac)
200A (4-8A @ 250Vac)
10000A (116-8A @ 125Vac)
1000A (9-30A @ 32Vac)
MDQ
MDA
Specifications
Description:
Dual-element,
time-delay fuse.
Dimensions: 14 x 1 14
(6.4 x 31.7mm).
Specifications
Description: Time-delay fuse.
Dimensions: 14 x 1 14 (6.35 x
31.75mm).
Construction: Ceramic tube
with nickel-plated brass
endcaps.
Ratings:
Volts 250Vac (or less)
125Vdc (20A- 30A)
32Vdc (Self certified)
Amps 14-30A
IR** 35A (14-1A @ 250Vac)
100A (112-2A @ 250Vac)
200A (212-10A @ 250Vac)
750A (12-15A @ 250Vac)
1500A (20-30A @ 250Vac)
10kA (14-30A @ 125Vac)
10kA (20-30A @ 125Vdc)
Construction: Glass
tube with nickel-plated
brass endcaps.
Ratings:
Volts 250Vac (1100-7A)
32Vac (712-15A)
32Vdc (Self Certified)
Amps 1100-15A
IR 35A (1100-1A @ 250Vac)
100A (114-3A @ 250Vac)
200A (4-7A @ 250Vac)
1000A (712-12A @ 32Vac)
Agency information: Std. 248-14,
UL Listed, File E19180; Guide JDYX,
1
16-7A CSA Certification, File 47233,
Class 1422-01, 116 -7A, UL Recognized,
Guide JDYX2, File E19180, 7.1-30A.
Features and benefits
Dual-element design allows closer
sizing to inductive circuits than any
other fuses.
Typical applications
Electronic relay and control circuits
Catalog numbers (amps)
MDL-V-1-R
MDL-V-1- 1 4-R
MDL-V-1- 12-R
MDL-V-2-R
MDL-V-2- 14-R
MDL-V-2- 12-R
MDL-V-3-R
MDL-V-3- 210-R
MDL-V-4-R
MDL-V-5-R
MDL-V-6-R
MDL-V-7-R
MDL-V-8-R
MDL-V-9-R
MDL-V-10-R
MDL-V-12-R
MDL-V-15-R
MDL-V-20-R
MDL-V-25*
MDL-V-30*
MDL- 116-R
MDL- 110-R
MDL- 18-R
MDL- 210-R
MDL- 316-R
MDL- 14-R
MDL- 310-R
MDL- 38-R
MDL- 12-R
MDL- 34-R
MDL-1-R
MDL-1- 14-R
MDL-1- 12-R
MDL-2-R
MDL-2- 14-R
MDL-2- 12-R
MDL-3-R
MDL-3- 210-R
MDL-4-R
MDL-5-R
MDL-6-R
MDL-7-R
MDL-8-R
MDL-9-R
MDL-10-R
MDL-12-R
MDL-15-R
MDL-20-R
MDL-25*
MDL-30*
MDQ-V-1-12
MDQ-V-1-610
MDQ-V-1-810
MDQ-V-2
MDQ-V-2-14
MDQ-V-2-12
MDQ-V-2-810
MDQ-V-3
MDQ-V-3-210
MDQ-V-4
MDQ-V-5
MDQ-V-6
MDQ-V-6-14
MDQ-V-7
MDQ-V-7-12
MDQ-V-8
MDQ-V-9
MDQ-V-10
MDQ-V-12
MDQ-15
MDQ-1-12
MDQ-1-610
MDQ-1-810
MDQ-2
MDQ-2-14
MDQ-2-12
MDQ-2-810
MDQ-3
MDQ-3-210
MDQ-4
MDQ-5
MDQ-6
MDQ-6-14
MDQ-7
MDQ-7-12
MDQ-8
MDQ-9
MDQ-10
MDQ-12
MDQ-15
1007July 2015
MDA-V-3-R
MDA-V-4-R
MDA-V-5-R
MDA-V-6-R
MDA-V-7-R
MDA-V-8-R
MDA-V-10-R
MDA-V-12-R
MDA-V-15-R
MDA-V-20-R
MDA-V-25A-R
MDA-V-30A-R
MDA-12-R
MDA-15-R
MDA-20-R
MDA-25A-R
MDA-30A-R
HTC-45M
HTC-50M
HTC-60M
1.303"
Mounting Holes
(33.1mm)
Dimensions - in (mm)
1.303"
(33.1mm)
Printed Circuit
Board
Specifications
Description: Four-leg PCB stand-off
fuse holder.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 250V
Amps: 6.3A
Agency information:
See specifications table notes 1, 4.
Dimensions - in (mm)
HTC-65M (4-Leg)
Mounting Holes
_ 0.002" Dia. (Typ.)
0.051" +
( 1.30 _+ 0.05mm)
0.394"
.886"
(3.5mm)
(10.0mm)
Printed Circuit
Board
0.512"
(3.5mm)
0.512"
(13.0mm)
S
FU E
.591"
mm)
S
FU E
(15.0mm)
0.461"
0.461"
(11.7mm)
.102
.138"
(13.0mm)
(11.7mm)
(9.0mm)
.551"
0.394"
.354"
(22.5mm)
(10.0mm)
Specifications
Terminals Tin-plated brass with 3mm (HTC-35M, -55M)
and 4.8mm (HTC-70M).
Molded materials High temperature thermoplastic that
meets the flammability ratings of UL 94VO; Glow Wire Test:
960C per IEC 695-2-1.
Solderability In accordance with IEC 68-2-20.
Electrical Contact resistance: <10mW;
_
Insulation
Resistance: >10MW;
_
dielectric strength >2000Vac.
_
Ratings 250V, 10A, UL
(1.3mm)
1)
2)
3)
4)
5)
1007July 2015
Eaton.com/bussmannseries
4-9
Electronic
fuses
Dimensions - in (mm)
Specifications
Description: PCB horizontal mount
bayonet cap and fuse holder.
Dimensions: See dimensions
illustration.
Ratings:
See specifications table.
Agency information:
See specifications table notes 1, 2.
4
HBH-I
HBV-I
(for 14 x 1 14 fuses)
HBH-M
HBV-M
HBW-I
(for 14 x 1 14 fuses)
(for 14 x 1 14 fuses)
HBW-M
PCB horizontal
mount
without stability
Specifications
Description: PCB
horizontal mount
fuse holder.
Dimensions: See
dimensions
illustration.
Ratings:
See specifications table.
Specifications
Description: PCB
vertical mount fuse
holder with stability
pins.
Dimensions: See
dimensions illustration.
Ratings:
See specifications table.
pins
Dimensions - in (mm)
Dimensions - in (mm)
Specifications
Description: PCB
vertical mount fuse
holder without stability
pins.
Dimensions: See dimensions
illustration.
0
Ratings:
See specifications table.
Dimensions - in (mm)
(13.5mm)
0.531"
(5.0mm)
0.200"
HBV
0.510"
(13.0mm)
0.510"
(5.0mm)
0.200"
(13.5mm)
0.531"
(47.0mm)
(47.0mm)
1.855"
(10.0mm)
0.400"
1.855"
(1.3mm)
Panel
PC Board
(10.0mm)
0.400"
PC Board
0.040"
0.040"
0.580"
Panel
Dia. 2 Holes
(1.3mm)
(1.05mm)
(1.05mm)
(14.9mm)
0.050"
HBW
(13.0mm)
(14.9mm)
0.580"
FBI
FBM
4-10
1007July 2015
Eaton.com/bussmannseries
HTC-15M, HTC-140M
PCB mounted fuse holder and snap-on cover
0.217 "
1.047"
(13.5mm)
(9.0mm)
HTC-140M
Cover
0.571"
(14.5mm)
(5.5mm)
0.531"
0.345"
(26.6mm)
Mounting Holes
0.890"
(22.60mm)
0.866"
(22.0mm)
0.177"
(4.5mm)
0.319"
(23.6mm)
0.61"
(15.5mm)
(0.79mm)
0.012"
0.217"
(0.3mm)
(5.5mm)
0.50"
0.50"
(12.7mm)
(12.7mm)
4.32mm
HTC-210M
2.54mm
6.22mm
3.91mm
2.85mm
1A3399
PCB fuseclips with end stops and straight leads
Catalog numbers
Clip material*
Finish
1A3399-01
Beryllium copper* Silver
1A3399-04-R
Beryllium copper* Bright tin
1A3399-10-R
Spring bronze
Bright tin
8.73mm
6.26mm
0.062"
0.115"
0.125"
(1.6mm)
(2.9mm)
0.254"
(3.2mm)
0.237"
(6.5mm)
0.060"
(6.0mm)
(1.5mm)
2.29mm
2.54mm
1.46mm
2.54mm
0.225"
(5.7mm)
0.125"
(3.2mm)
Electronic
fuses
0.157"
(3.99mm)
0.929"
0.031"
BUSS
(12.7mm)
BUSS
0.50"
(8.1mm)
0.177"
(4.5mm)
BUSS
HTC-200M
0.030"
(1.6mm)
0.188"
(4.8mm)
0.180"
1A5018
0.440"
(4.57mm)
0.230"
(5.84mm)
(11.2mm)
0.140"
0.047"
(3.7mm)
(1.2mm)
0.180"
(4.6mm)
1A5601
PCB fuseclips (0-7A)
Catalog number
Clip material
1A5601
Cartridge brass
Data Sheet: 2131
0.246"
0.344" + 0.015"
(6.3mm)
(8.73mm + 0.38mm)
Finish
Bright tin
0.344" + 0.015"
(8.73mm + 0.38mm)
0.141" + 0.015"
(3.58mm + 0.38mm)
0.022" + 0.002"
0.060"
0.266"
(1.5mm)
(6.75mm)
0.032" + 0.002"
(0.56mm + 0.05mm)
1A5602
PCB fuseclips (0-7A)
Catalog number
Clip material
1A5602
Cartridge brass
Data Sheet: 2131
0.250"
(6.35mm)
(0.81mm + 0.05mm)
0.219"
(5.57mm)
Finish
Bright tin
0.500"
(6.35mm)
0.140"
(3.56mm)
0.093"
0.216"
(5.48mm)
0.250"
(12.70mm)
1007July 2015
(2.36mm)
LEGS TO FIT
IN 0.052" (1.3mm) DIA.
HOLES ON CENTER
0.047"
(1.19mm)
Eaton.com/bussmannseries
4-11
(2.6mm)
1A3398
0.250"
(7.1mm)
(6.35mm)
0.155"
0.245"
(3.94mm)
(6.2mm)
0.410"
(10.4mm)
0.060"
(1.5mm)
0.320"
(8.13mm)
0.140"
0.102" Dia.
(2.6mm)
"
0.280"
(3.6mm) (7.1mm)
1A1907
PCB fuseclips with end stops and straight leads
Catalog numbers
Clip material*
Finish
1A1907-02
Cartridge brass
None/bright dipped
1A1907-03-R
High performance copper* Bright tin
1A1907-05
High performance copper* Silver
1A1907-06-R
Cartridge brass
Bright tin
0.102" Dia.
(2.6mm)
0.255"
(6.5mm)
0.280"
(7.1mm)
0.155"
(3.94mm)
0.245"
(6.2mm)
0.410"
0.102" Dia.
(10.4mm)
0.060"
0.140"
(1.5mm)
(2.6mm)
(8.13mm)
0.280"
0.245"
(6.2mm)
out leads
Finish
Bright tin
Bright tin
0.280"
(7.1mm)
(3.6mm) (7.1mm)
0.320"
1A4533
PCB fuseclips without end stops or angled
Catalog numbers
Clip material*
1A4533-01-R
High performance copper*
1A4533-06-R
Cartridge brass
0.280"
(7.1mm)
0.155"
(3.94mm)
0.102"
(2.6mm)
0.410"
(10.4mm)
0.255"
(6.5mm)
0.060"
(1.5mm)
0.320"
0.150"
(3.81mm)
0.228"
0.280"
(7.11mm)
(5.79mm)
0.323"
(8.20mm)
1A4534
0.245"
(6.2mm)
(8.13mm)
0.155"
(3.94mm)
0.102"
(2.6mm)
0.410"
(10.4mm)
0.255"
(6.5mm)
0.060"
(1.5mm)
0.320"
0.150"
(3.81mm)
0.228"
(8.13mm)
(5.79mm)
0.323"
(8.20mm)
1A1119
0.132"
0.285"
(3.4mm)
(7.24mm)
0.420"
0.187"
(10.67mm)
0.250"
(6.5mm)
(4.8mm)
0.312"
(7.9mm)
0.290"
0.155"
0.080"
(2.03mm)
0.280"
(7.11mm)
(7.4mm)
(3.9mm)
0.360"
(9.14mm)
1A1120
PCB fuseclips without end stops or angled
Catalog numbers
Clip material*
1A1120-02
Cartridge brass
1A1120-05
High performance copper*
1A1120-06-R
High performance copper*
1A1120-09-R
Cartridge brass
in leads
Finish
None/bright dipped
Silver
Bright tin
Bright tin
0.272
[6.91]
0.250
[6.35]
0.080
[2.03]
0.320
[8.13]
0.130.003
[3.3mm0.08]
C
L
0.400.010
[10.160.25]
0.155.010
[3.940.25]
4-12
1007July 2015
Eaton.com/bussmannseries
0.290.010
[7.370.25]
0.363.003
[9.220.08]
0.187
[4.75] 0.312
[7.92]
End
stop
5681-08
No
5681-01
5681-15-R
5682-01
5682-02
5682-11-R
5682-41-R
5682-44-R
Yes
Dimensions (Inches)
D
E
B (To
(Height)
(Width)
Hole
dia.
Nickel
0.265
0.41
0.32
0.132 Fig. 2
BeCu
Silver
0.108
BeCu
Bright tin
0.131
0.262
0.41
0.32
0.132 Fig. 1
Bright tin
0.132
Clip
mat.**
BeCu
Spg. br.
Spg. br.
BeCu
Spg. br.
Spg. br.
Finish
Silver
Bright tin
Silver
Bright tin
0.106
Ref.
Figure 1
D
E
Figure 2
Electronic
fuses
1007July 2015
Eaton.com/bussmannseries
4-13
5674-01
5674-10
5674-41
End
stop
No
Yes
Clip
mat.**
Finish
BeCu
Silver
Spg. br.
Bright tin
BeCu
Bright tin
Spg. br.
Bright tin
B (To
Dimensions (Inches)
D
E
0.362
(Height) (Width)
0.52
0.38
Hole
dia. Ref.
0.168
0.356
0.52
0.38
0.172 Fig. 1
0.172 Fig. 2
1A3400***
For 13/32 diameter fuses
With end stops and straight leads
Dimensional data
0.050" 0.437"
Figure 1
(1.27mm) (11.1mm)
0.218"
(5.54mm)
0.142" Dia.
(3.61mm)
0.470"
(11.94mm)
0.710"
(18.03mm)
Specifications:
0.080"
0.380"
(2.03mm)
(9.65mm)
0.470"
(11.94mm)
1A3400-12
Catalog
number
1A3400-09
1A3400-10
1A3400-12
Clip
material
Copper-clad steel
Copper-clad steel
Spring brass
Finish
Bright tin
Silver
Bright tin
***For RoHS compliant version add -R option code suffix to part number.
5956-16
5960-07
End
stop
No
5960-09
5960-44
5960-51
5960-53
Clip
mat.**
Finish
end stop)
BeCu
Silver
0.168
Nickel
0.20
Spg. br.
BeCu
Yes
5960-61-R
5960-62-R
Spg. br.
5960-63-R
Silver
Spg. br.
Bright dip*
Spg. br.
Bright tin
Spg. br.
Spg. br.
Spg. br.
5960-64-R
Bright tin
Spr. br.
Bright dip*
Bright tin
Bright tin
Bright tin
Dimensions (inches)
B (To
0.312
0.71
0.47
(Contact) (Height)
(Width)
0.20
0.168
0.20
Hole
dia.
Ref.
0.172 Fig. 2
0.196
0.172
0.387
0.71
0.47
0.168
0.197
0.196 Fig. 1
0.172
0.196
0.168
0.132
0.20
0.172
0.20
0.128
Figure 2
5591-42
5591-52-R
5592-01
End
stop
Yes
No
Clip
mat.**
Finish
Spg. br.
Bright tin
Spg. br.
BeCu
Bright dip*
Silver
Dimensions (inches)
C
D
E
Hole
B (To
end stop) (Contact) (Height) (Width) dia.
0.26
0.252
0.51
0.56
0.89
0.875
0.60
0.60
Ref.
0.172 Fig. 1
0.20
Fig. 2
1007July 2015
Eaton.com/bussmannseries
Amp
rating
20A max.
30A max.
15A max.
Contents
Description
Page
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Current-liminting fuses
E-Rated 2.75kV - 15.5kV . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
R-Rated 2.4kV - 7.2kV . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-20
PT E-Rated 2.475kV - 38kV . . . . . . . . . . . . . . . . . . . . . . . 5-24
PT fast-acting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-30
British IEC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-31
DIN IEC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-32
Expulsion fuse links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-33
EEI-NEMA Type K and T Type H and N . . . . . . . . . . . . . . 5-35
Medium voltage
fuses
1007July 2015
Eaton.com/bussmannseries
5-1
Fuse types
5-2
1007July 2015
Eaton.com/bussmannseries
Current-limiting
Catalog symbols:
2CLE-_E
JCX-_E
Ratings:
Description:
Volts 2.75kV
Amps 10 to 450A
Interrupting ratings
50kA RMS Sym (2CLE-_E)
Agency information:
Amp rating
Fuse
mounting
type
Diameter
A
Clip center
B
Length
C
Mounting
(including live parts, end fittings)*
Porcelain
insulator
Glass-polyester
insulator
Live parts
(including end
fittings)
2CLE-PNM-C
2CLE-GNM-C
CLE-NL-C
2CLE-PDM-C
2CLE-GDM-C
CLE-DL-C
CLE-DF-C
2CLE-PNM-D
2CLE-GNM-D
CLE-NL-D
2CLE-PDM-D
2CLE-GDM-D
CLE-DL-D
2CLE-PNM-E
2CLE-GNM-E
CLE-NL-E
2CLE-PDM-E
5CLE-GDM-E
CLE-DL-E
CLE-DF-E
End fittings
(disconnect
only)
CLE
Non-disconnect
60
Disconnect**
60
10E225E
Single barrel
Non-disconnect
60
Disconnect**
60
250E300E
350X-450X
Double barrel
Non-disconnect
60
Disconnect**
60
2 (51)
8.1 (206)
9.5 (241)
3 (76)
7 (178)
10.9 (277)
3 (76)
7 (178)
10.9 (277)
CLE-DF-D
Medium voltage
fuses
15E25E
Single barrel
Recommended fuseclips:
C
B
Description
Fuse
diameter in (mm)
Catalog
number
Enclosed fuseclip
2 (51)
A3354710*
Enclosed fuseclip
3 (76)
A3354730*
Open fuseclip
3 (76)
1A0065
3 (76)
9078A67G04
3.31
(84.1)
B
A
1007July 2015
Eaton.com/bussmannseries
5-3
Current-limiting
Amp rating
Diameter
B
Clip centers
C
Interrupting
rating kA
(RMS Sym.)
Number of
barrels
Installation
location
Catalog
number
9.2 (234)
2 (51)
7 (178)
40
Indoor/outdoor
JCX-1E
9.2 (234)
2 (51)
7 (178)
40
Indoor/outdoor
JCX-2E
9.2 (234)
2 (51)
7 (178)
40
Indoor/outdoor
JCX-3E
9.2 (234)
2 (51)
7 (178)
40
Indoor/outdoor
JCX-5E
9.2 (234)
2 (51)
7 (178)
40
Indoor/outdoor
JCX-7E
10
9.2 (234)
2 (51)
7 (178)
40
Indoor/outdoor
JCX-10E
10
10.9 (277)
3 (76)
7 (178)
50
Indoor
2CLE-10E
15
9.5 (241)
2 (51)
8.1 (206)
50
Indoor
2CLE-15E
20
9.5 (241)
2 (51)
8.1 (206)
50
Indoor
2CLE-20E
25
9.5 (241)
2 (51)
8.1 (206)
50
Indoor
2CLE-25E
30
10.9 (277)
3 (76)
7 (178)
50
Indoor
2CLE-30E
40
10.9 (277)
3 (76)
7 (178)
50
Indoor
2CLE-40E
50
10.9 (277)
3 (76)
7 (178)
50
Indoor
2CLE-50E
65
10.9 (277)
3 (76)
7 (178)
50
Indoor
2CLE-65E
80
10.9 (277)
3 (76)
7 (178)
50
Indoor
2CLE-80E
100
10.9 (277)
3 (76)
7 (178)
50
Indoor
2CLE-100E
125
10.9 (277)
3 (76)
7 (178)
50
Indoor
2CLE-125E
150
10.9 (277)
3 (76)
7 (178)
50
Indoor
2CLE-150E
200
10.9 (277)
3 (76)
7 (178)
50
Indoor
2CLE-200E
225
10.9 (277)
3 (76)
7 (178)
50
Indoor
2CLE-225E
250*
10.9 (277)
3 (76)
7 (178)
50
Indoor
2CLE-250E
300*
10.9 (277)
3 (76)
7 (178)
50
Indoor
2CLE-300E
350**
10.9 (277)
3 (76)
7 (178)
50
Indoor
2CLE-350X
400**
10.9 (277)
3 (76)
7 (178)
50
Indoor
2CLE-400X
450**
10.9 (277)
3 (76)
7 (178)
50
Indoor
2CLE-450X
* 250A and 300A ratings may also be applied at 280 and 325 amps respectively, but fuses will no longer be complaint with ANSI E Rating criteria.
** Does not comply with ANSI C37.46 for E rating.
1007July 2015
Eaton.com/bussmannseries
Current-limiting
Catalog symbols:
Description:
General purpose:
5CLE-_E-D (10-25A)
5CLE-_E (10-1350A)
5HLE-_E (10-450A)
JCY-_E (1-25A)
MV055F_ (10-450A)
Ratings*:
Volts 5.5kV
Amps 1 to 1350A
Agency information:
Fuse
mounting
type
Voltage
BIL (kV)
Diameter
A
Clip center
B
Length
C
Porcelain insulator
Glass-polyester
insulator
Live parts
(including
end fittings)
5CLE-PNM-D
5CLE-GNM-D
CLE-NL-D
5CLE-PDM-D
5CLE-GDM-D
CLE-DL-D
5CLE-PNM-C
5CLE-GNM-C
CLE-NL-C
5CLE-PDM-C
5CLE-GDM-C
CLE-DL-C
5CLE-PNM-E
5CLE-GNM-E
CLE-NL-E
5CLE-PDM-E
5CLE-GDM-E
CLE-DL-E
End fittings
(disconnect
only)
CLE
10E-D25E-D
30E250E
Single barrel
Non-disconnect
60
Disconnect**
60
15E25E
Single barrel
Non-disconnect
60
Disconnect**
60
300E450E
Double barrel
Non-disconnect
60
Disconnect**
60
Consult factory
3.0 (76.2)
14.0 (355.6)
17.9 (454.7)
CLE-DF-D
2.0 (50.8)
11.5 (292.1)
12.9 (327.7)
3.0 (76.2)
14.0 (355.6)
17.9 (454.7)
60
4.0 (101.6)
N/A
N/A
4.0 (101.6)
N/A
N/A
10E-D250E
Single barrel
Non-disconnect
60
Disconnect
60
300E450E
Double barrel
Non-disconnect
60
Disconnect
60
CLE-DF-C
CLE-DF-E
HLE
3.0 (76.2)
12.0 (304.8)
15.9 (403.9)
3.0 (76.2)
12.0 (304.8)
15.9 (403.9)
5HLE-PNM-D
5HLE-GNM-D
CLE-NL-D
5HLE-PDM-D
5HLE-GDM-D
CLE-DL-D
5HLE-PNM-E
5HLE-GNM-E
CLE-NL-E
5HLE-PDM-E
5HLE-GDM-E
CLE-DL-E
CLE-DF-D
CLE-DF-E
3.31
(84.1)
B
A
1007July 2015
Eaton.com/bussmannseries
5-5
Medium voltage
fuses
Amp rating
Mounting
(including live parts, end fittings)*
Length A
Diameter B
Clip centers C
Interrupting
rating kA
(RMS Sym.)
11.2 (284)
2 (51)
9 (229)
40
Indoor/outdoor
JCY-1E
11.2 (284)
2 (51)
9 (229)
40
Indoor/outdoor
JCY-2E
11.2 (284)
2 (51)
9 (229)
40
Indoor/outdoor
JCY-3E
11.2 (284)
2 (51)
9 (229)
40
Indoor/outdoor
JCY-5E
11.2 (284)
2 (51)
9 (229)
40
Indoor/outdoor
JCY-7E
10
11.2 (284)
2 (51)
9 (229)
40
Indoor/outdoor
JCY-10E
10
17.9 (455)
3 (76)
14 (356)
63
Indoor/outdoor
5CLE-10E-D
10
15.9 (404)
3 (76)
12 (305)
63
Indoor/outdoor
5HLE-10E
15
11.2 (284)
2 (51)
9 (229)
40
Indoor/outdoor
JCY-15E
15
12.9 (328)
2 (51)
11.5 (292)
50
Indoor
5CLE-15E*
15
17.9 (455)
3 (76)
14 (356)
63
Indoor/outdoor
5CLE-15E-D
15
15.9 (404)
3 (76)
12 (305)
63
Indoor/outdoor
5HLE-15E
20
11.2 (284)
2 (51)
9 (229)
40
Indoor/outdoor
JCY-20E
20
12.9 (328)
2 (51)
11.5 (292)
50
Indoor
5CLE-20E*
20
17.9 (455)
3 (76)
14 (356)
63
Indoor/outdoor
5CLE-20E-D
20
15.9 (404)
3 (76)
12 (305)
63
Indoor/outdoor
5HLE-20E
25
11.2 (284)
2 (51)
9 (229)
40
Indoor/outdoor
JCY-25E
25
12.9 (328)
2 (51)
11.5 (292)
50
Indoor
5CLE-25E*
25
17.9 (455)
3 (76)
14 (356)
63
Indoor/outdoor
5CLE-25E-D
25
15.9 (404)
3 (76)
12 (305)
63
Indoor/outdoor
5HLE-25E
30
17.9 (455)
3 (76)
14 (356)
63
Indoor/outdoor
5CLE-30E
30
15.9 (404)
3 (76)
12 (305)
63
Indoor/outdoor
5HLE-30E
40
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
5CLE-40E
40
15.9 (404)
3 (76)
12 (305)
63
Indoor/outdoor
5HLE-40E
50
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
5CLE-50E
50
15.9 (404)
3 (76)
12 (305)
63
Indoor/outdoor
5HLE-50E
65
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
5CLE-65E
65
15.9 (404)
3 (76)
12 (305)
63
Indoor/outdoor
5HLE-65E
80
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
5CLE-80E
80
15.9 (404)
3 (76)
12 (305)
63
Indoor/outdoor
5HLE-80E
100
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
5CLE-100E
100
15.9 (404)
3 (76)
12 (305)
63
Indoor/outdoor
5HLE-100E
125
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
5CLE-125E
125
15.9 (404)
3 (76)
12 (305)
63
Indoor/outdoor
5HLE-125E
150
17.9 (455)
3 (76)
14 (356)
63
Indoor/outdoor
5CLE-150E
150
15.9 (404)
3 (76)
12 (305)
63
Indoor/outdoor
5HLE-150E
175
17.9 (455)
3 (76)
14 (356)
63
Indoor/outdoor
5CLE-175E
175
15.9 (404)
3 (76)
12 (305)
63
Indoor/outdoor
5HLE-175E
200
17.9 (455)
3 (76)
14 (356)
63
Indoor/outdoor
5CLE-200E
200
15.9 (404)
3 (76)
12 (305)
63
Indoor/outdoor
5HLE-200E
250
17.9 (455)
3 (76)
14 (356)
63
Indoor/outdoor
5CLE-250E
250
15.9 (404)
3 (76)
12 (305)
63
Indoor/outdoor
5HLE-250E
300
17.9 (455)
3 (76)
14 (356)
63
Indoor/outdoor
5CLE-300E
300
15.9 (404)
3 (76)
12 (305)
63
Indoor/outdoor
5HLE-300E
350
17.9 (455)
3 (76)
14 (356)
63
Indoor/outdoor
5CLE-350E
350
15.9 (404)
3 (76)
12 (305)
63
Indoor/outdoor
5HLE-350E
400
17.9 (455)
3 (76)
14 (356)
63
Indoor/outdoor
5CLE-400E
400
15.9 (404)
3 (76)
12 (305)
63
Indoor/outdoor
5HLE-400E
450
17.9 (455)
3 (76)
14 (356)
63
Indoor/outdoor
5CLE-450E
450
15.9 (404)
3 (76)
12 (305)
63
Indoor/outdoor
5HLE-450E
Number of
barrels
Installation
location
Catalog number
5-6
1007July 2015
Eaton.com/bussmannseries
Current-limiting
Diameter
B
Clip centers
C
Interrupting
rating kA
(RMS Sym.)
Number of
Barrels
Installation
location
15.7 (399)
2 (51)
12 (305)
50
Indoor
MV055F1CAX5E
15.7 (399)
2 (51)
12 (305)
50
Indoor
MV055F1CAX7E
Amp rating
Catalog Number
10
15.7 (399)
2 (51)
12 (305)
50
Indoor
MV055F1CAX10E
10
15.7 (399)
3 (76)
12 (305)
50
Indoor
MV055F1DAX10E
15
15.7 (399)
2 (51)
12 (305)
50
Indoor
MV055F1CAX15E
15
15.7 (399)
3 (76)
12 (305)
50
Indoor
MV055F1DAX15E
20
15.7 (399)
2 (51)
12 (305)
50
Indoor
MV055F1CAX20E
20
15.7 (399)
3 (76)
12 (305)
50
Indoor
MV055F1DAX20E
25
15.7 (399)
2 (51)
12 (305)
50
Indoor
MV055F1CAX25E
25
15.7 (399)
3 (76)
12 (305)
50
Indoor
MV055F1DAX25E
30
15.7 (399)
2 (51)
12 (305)
50
Indoor
MV055F1CAX30E
30
15.7 (399)
3 (76)
12 (305)
50
Indoor
MV055F1DAX30E
40
15.7 (399)
2 (51)
12 (305)
50
Indoor
MV055F1CAX40E
40
15.7 (399)
3 (76)
12 (305)
50
Indoor
MV055F1DAX40E
50
15.7 (399)
2 (51)
12 (305)
50
Indoor
MV055F1CAX50E
50
15.7 (399)
3 (76)
12 (305)
50
Indoor
MV055F1DAX50E
65
15.7 (399)
2 (51)
12 (305)
50
Indoor
MV055F1CAX65E
65
15.7 (399)
3 (76)
12 (305)
50
Indoor
MV055F1DAX65E
80
15.7 (399)
3 (76)
12 (305)
50
Indoor
MV055F1DAX80E
100
15.7 (399)
3 (76)
12 (305)
50
Indoor
MV055F1DAX100E
15.7 (399)
3 (76)
12 (305)
50
Indoor
MV055F1DAX125E
15.7 (399)
3 (76)
12 (305)
50
Indoor
MV055F1DAX150E
175
15.7 (399)
3 (76)
12 (305)
50
Indoor
MV055F1DAX175E
200
15.7 (399)
3 (76)
12 (305)
50
Indoor
MV055F1DAX200E
250
15.7 (399)
3 (76)
12 (305)
50
Indoor
MV055F2DAX250E
300
15.7 (399)
3 (76)
12 (305)
50
Indoor
MV055F2DAX300E
350
15.7 (399)
3 (76)
12 (305)
50
Indoor
MV055F2DAX350E
400
15.7 (399)
3 (76)
12 (305)
50
Indoor
MV055F2DAX400E
450
15.7 (399)
3 (76)
12 (305)
50
Indoor
MV055F2DAX450E
Description
Fuse
diameter in (mm)
Catalog
number
Enclosed fuseclip
2 (51)
A3354710*
Enclosed fuseclip
3 (76)
A3354730*
Open fuseclip
3 (76)
1A0065
3 (76)
9078A67G04
1007July 2015
Eaton.com/bussmannseries
5-7
Medium voltage
fuses
125
150
Current-limiting
HCL clip-lock
Catalog symbols:
Indicator*
0.5 (12.7)
0.25
(6.4)
4.31 (109.5)
1.25
(31.8)
Ratings*:
Volts 5.5kV
Amps 10 to 900A
1.25
(31.8)
7.94 (201.7)
* See catalog number tables for voltages, ampacities and interrupting ratings by
catalog number.
Agency information:
11.62 (295.1)
Dimensions - in (mm)
BHLE/CLE bolt-on
2.12
(53.8)
A
Indicator to be
located here
2.12
(53.8)
1.75
14.50
3.31
(84.1)
C
A
16.00
Indicator to be
located here
3.31
(84.1)
9.29
3.31
(84.1)
1.19
2.12
(53.8)
C
18.38
A
5-8
1007July 2015
Eaton.com/bussmannseries
Current-limiting
Number of barrels
Catalog number
10
63
5AHLE-10E
15
63
5AHLE-15E
20
63
5AHLE-20E
25
63
5AHLE-25E
30
63
5AHLE-30E
40
63
5AHLE-40E
50
63
5AHLE-50E
65
63
5AHLE-65E
80
63
5AHLE-80E
100
63
5AHLE-100E
125
63
5AHLE-125E
150
63
5AHLE-150E
175
63
5AHLE-175E
200
63
5AHLE-200E
250
63
5AHLE-250E
300
63
5AHLE-300E
350
63
5AHLE-350E
400
63
5AHLE-400E
450
63
5AHLE-450E
Dimensions - in (mm)
Overall length
A
Diameter
B
Hole centers
C
Interrupting
rating kA
(RMS Sym.)
Number of
barrels
Installation
location
Catalog
number
10
16.8 (427)
3 (76)
N/A
63
Indoor
5HCL-10E
15
16.8 (427)
3 (76)
N/A
63
Indoor
5HCL-15E
20
16.8 (427)
3 (76)
N/A
63
Indoor
5HCL-20E
25
16.8 (427)
3 (76)
N/A
63
Indoor
5HCL-25E
30
16.8 (427)
3 (76)
N/A
63
Indoor
5HCL-30E
40
16.8 (427)
3 (76)
N/A
63
Indoor
5HCL-40E
50
16.8 (427)
3 (76)
N/A
63
Indoor
5HCL-50E
65
16.8 (427)
3 (76)
N/A
63
Indoor
5HCL-65E
80
16.8 (427)
3 (76)
N/A
63
Indoor
5HCL-80E
100
16.8 (427)
3 (76)
N/A
63
Indoor
5HCL-100E
125
16.8 (427)
3 (76)
N/A
63
Indoor
5HCL-125E
150
16.8 (427)
3 (76)
N/A
63
Indoor
5HCL-150E
175
16.8 (427)
3 (76)
N/A
63
Indoor
5HCL-175E
200
22.8 (579)
3 (76)
N/A
63
Indoor
5HCL-200E
250
22.8 (579)
3 (76)
N/A
63
Indoor
5HCL-250E
300
22.8 (579)
3 (76)
N/A
63
Indoor
5HCL-300E
400
22.8 (579)
3 (76)
N/A
63
Indoor
5HCL-400E
450
22.8 (579)
3 (76)
N/A
63
Indoor
5HCL-450E
500
22.8 (579)
3 (76)
N/A
63
Indoor
5HCL-500E
600
22.8 (579)
3 (76)
N/A
63
Indoor
5HCL-600E
750
22.8 (579)
3 (76)
N/A
63
Indoor
5HCL-750E
900
22.8 (579)
3 (76)
N/A
63
Indoor
5HCL-900E
1007July 2015
Amp Rating
Eaton.com/bussmannseries
5-9
Current-limiting
Overall length
A
Diameter
B
Hole centers
C
Interrupting
rating kA
(RMS Sym.)
Number of
barrels
Installation
location
Catalog
number
10
19.2 (488)
3 (76)
17.9 (455)
63
Indoor
5BHLE-10E
15
19.2 (488)
3 (76)
17.9 (455)
63
Indoor
5BHLE-15E
20
19.2 (488)
3 (76)
17.9 (455)
63
Indoor
5BHLE-20E
25
19.2 (488)
3 (76)
17.9 (455)
63
Indoor
5BHLE-25E
30
19.2 (488)
3 (76)
17.9 (455)
63
Indoor
5BHLE-30E
40
19.2 (488)
3 (76)
17.9 (455)
63
Indoor
5BHLE-40E
50
19.2 (488)
3 (76)
17.9 (455)
63
Indoor
5BHLE-50E
65
19.2 (488)
3 (76)
17.9 (455)
63
Indoor
5BHLE-65E
80
19.2 (488)
3 (76)
17.9 (455)
63
Indoor
5BHLE-80E
100
19.2 (488)
3 (76)
17.9 (455)
63
Indoor
5BHLE-100E
125
19.2 (488)
3 (76)
17.9 (455)
63
Indoor
5BHLE-125E
150
19.2 (488)
3 (76)
17.9 (455)
63
Indoor
5BHLE-150E
175
19.2 (488)
3 (76)
17.9 (455)
63
Indoor
5BHLE-175E
200
19.2 (488)
3 (76)
17.9 (455)
63
Indoor
5BHLE-200E
200
25.1 (637)
3 (76)
23.7 (602)
63
Indoor
5BHCL-200E
250
19.2 (488)
3 (76)
17.9 (455)
63
Indoor
5BHLE-250E
250
25.1 (637)
3 (76)
23.7 (602)
63
Indoor
5BHCL-250E
300
19.2 (488)
3 (76)
17.9 (455)
63
Indoor
5BHLE-300E
300
25.1 (637)
3 (76)
23.7 (602)
63
Indoor
5BHCL-300E
350
19.2 (488)
3 (76)
17.9 (455)
63
Indoor
5BHLE-350E
400
19.2 (488)
3 (76)
17.9 (455)
63
Indoor
5BHLE-400E
400
25.1 (637)
3 (76)
23.7 (602)
63
Indoor
5BHCL-400E
450
19.2 (488)
3 (76)
17.9 (455)
63
Indoor
5BHLE-450E
450
25.1 (637)
3 (76)
23.7 (602)
63
Indoor
5BHCL-450E
500
25.1 (637)
3 (76)
23.7 (602)
63
Indoor
5BHCL-500E
600
25.1 (637)
3 (76)
23.7 (602)
63
Indoor
5BHCL-600E
600
28.9 (734)
4 (102)
18.4 (467)
40
Indoor
5CLE-600E
750
25.1 (637)
3 (76)
23.7 (602)
63
Indoor
5BHCL-750E
750
28.9 (734)
4 (102)
18.4 (467)
40
Indoor
5CLE-750E
900
25.1 (637)
3 (76)
23.7 (602)
63
Indoor
5BHCL-900E
1100
19.8 (503)
4 (102)
18.4 (467)
31
Indoor
5CLE-1100E
1350
19.8 (503)
4 (102)
18.4 (467)
31
Indoor
5CLE-1350E
1007July 2015
Eaton.com/bussmannseries
Current-limiting
Catalog symbols:
8CLE-_E-D (10-25A)
8CLE-_E (10-350A)
8HLE-_E (10-350A)
Ratings*:
Description:
Volts 8.3kV
Amps 10 to 350A
Agency information:
Amp rating
Fuse
mounting
type
Voltage
BIL
(kV)
Length
C
Glass-polyester
insulator
Live parts
End fittings
(including
(disconnect
end fittings) only)
8CLE-PNM-D
8CLE-GNM-D
CLE-NL-D
8CLE-PDM-D
8CLE-GDM-D
CLE-DL-D
8CLE-PNM-C
8CLE-GNM-C
CLE-NL-C
8CLE-PDM-C
8CLE-GDM-C
CLE-DL-C
8CLE-PNM-E
8CLE-GNM-E
CLE-NL-E
8CLE-PDM-E
8CLE-GDM-E
CLE-DL-E
8HLE-PNM-D
8HLE-GNM-D
CLE-NL-D
8HLE-PDM-D
8HLE-GDM-D
CLE-DL-D
8HLE-PNM-E
8HLE-GNM-E
CLE-NL-E
8HLE-PDM-E
8HLE-GDM-E
CLE-DL-E
CLE
Non-disconnect
75
Disconnect**
75
15E25E
Single Barrel
Non-disconnect
75
Disconnect**
75
200E350E
Double barrel
Non-disconnect
75
Disconnect
75
10E-175E
Single barrel
Non-disconnect
75
Disconnect**
75
200E350E
Double barrel
Non-disconnect
75
Disconnect**
75
3.0 (76)
14 (356)
17.9 (455)
2.0 (51)
14 (356)
15.5 (394)
3.0 (76)
14 (356)
17.9 (455)
CLE-DF-D
CLE-DF-C
Medium voltage
fuses
10E-D25E-D
30E175E
Single barrel
CLE-DF-E
HLE
3.0 (76)
12 (305)
15.9 (404)
3.0 (76)
12 (305)
15.9 (404)
CLE-DF-D
CLE-DF-E
Recommended fuseclips:
Description
Catalog
number
Enclosed fuseclip
2 (51)
A3354710*
Enclosed fuseclip
3 (76)
A3354730*
Open fuseclip
3 (76)
1A0065
3 (76)
9078A67G04
3.31
(84.1)
B
A
1007July 2015
Eaton.com/bussmannseries
5-11
Current-limiting
Interrupting
rating kA
(RMS Sym.)
Number of
barrels
Installation
location
Catalog
number
Indoor/outdoor
8CLE-10E-D
Indoor
8CLE-15E*
Indoor/outdoor
8CLE-15E-D
Amp rating
Length A
Diameter B
10
17.9 (455)
3 (76)
14 (356)
50
15
15.5 (394)
2 (51)
14 (356)
50
15
17.9 (455)
3 (76)
14 (356)
50
20
15.5 (394)
2 (51)
14 (356)
50
Indoor
8CLE-20E*
20
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
8CLE-20E-D
25
15.5 (394)
2 (51)
14 (356)
50
Indoor
8CLE-25E*
8CLE-25E-D
25
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
30
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
8CLE-30E
40
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
8CLE-40E
50
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
8CLE-50E
65
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
8CLE-65E
80
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
8CLE-80E
100
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
8CLE-100E
125
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
8CLE-125E
150
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
8CLE-150E
175
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
8CLE-175E
200
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
8CLE-200E
250
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
8CLE-250E
300
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
8CLE-300E
350
17.9 (455)
3 (76)
14 (356)
50
Indoor/outdoor
8CLE-350E
15.9 (404)
3 (76)
12 (305)
50
Indoor/outdoor
8HLE-10E
15
15.9 (404)
3 (76)
12 (305)
50
Indoor/outdoor
8HLE-15E
20
15.9 (404)
3 (76)
12 (305)
50
Indoor/outdoor
8HLE-20E
25
15.9 (404)
3 (76)
12 (305)
50
Indoor/outdoor
8HLE-25E
30
15.9 (404)
3 (76)
12 (305)
50
Indoor/outdoor
8HLE-30E
40
15.9 (404)
3 (76)
12 (305)
50
Indoor/outdoor
8HLE-40E
50
15.9 (404)
3 (76)
12 (305)
50
Indoor/outdoor
8HLE-50E
65
15.9 (404)
3 (76)
12 (305)
50
Indoor/outdoor
8HLE-65E
80
15.9 (404)
3 (76)
12 (305)
50
Indoor/outdoor
8HLE-80E
100
15.9 (404)
3 (76)
12 (305)
50
Indoor/outdoor
8HLE-100E
125
15.9 (404)
3 (76)
12 (305)
50
Indoor/outdoor
8HLE-125E
150
15.9 (404)
3 (76)
12 (305)
50
Indoor/outdoor
8HLE-150E
175
15.9 (404)
3 (76)
12 (305)
50
Indoor/outdoor
8HLE-175E
200
15.9 (404)
3 (76)
12 (305)
50
Indoor/outdoor
8HLE-200E
250
15.9 (404)
3 (76)
12 (305)
50
Indoor/outdoor
8HLE-250E
300
15.9 (404)
3 (76)
12 (305)
50
Indoor/outdoor
8HLE-300E
350
15.9 (404)
3 (76)
12 (305)
50
Indoor/outdoor
8HLE-350E
1007July 2015
Eaton.com/bussmannseries
Current-limiting
Catalog symbols:
Volts 8.3kV
Amps 10 to 350A
0.5 (12.7)
1.25
(31.8)
1.25
(31.8)
* See catalog number tables for voltages, ampacities and interrupting ratings by
catalog number.
7.94 (201.7)
Agency information:
0.25
(6.4)
4.31 (109.5)
Ratings*:
Indicator*
Medium voltage
fuses
A
Indicator to be
located here
3.31
(84.1)
2.12
(53.8)
C
A
1007July 2015
Eaton.com/bussmannseries
5-13
Current-limiting
AHLE Type fuses (special dimension fuses for use with 7.2kV rated, 800 amp AMPGARD motor starting assemblies)
Amp rating
Number of barrels
Catalog number
10
50
8AHLE-10E
15
50
8AHLE-15E
20
50
8AHLE-20E
25
50
8AHLE-25E
30
50
8AHLE-30E
40
50
8AHLE-40E
50
50
8AHLE-50E
65
50
8AHLE-65E
80
50
8AHLE-80E
100
50
8AHLE-100E
125
50
8AHLE-125E
150
50
8AHLE-150E
175
50
8AHLE-175E
200
50
8AHLE-200E
250
50
8AHLE-250E
300
50
8AHLE-300E
350
50
8AHLE-350E
Diameter
Hole centers
Interrupting
rating kA
(RMS Sym.)
10
19.25 (488.9)
3 (76.2)
17.88 (454.2)
50
Indoor
8BHLE-10E
15
19.25 (488.9)
3 (76.2)
17.88 (454.2)
50
Indoor
8BHLE-15E
20
19.25 (488.9)
3 (76.2)
17.88 (454.2)
50
Indoor
8BHLE-20E
25
19.25 (488.9)
3 (76.2)
17.88 (454.2)
50
Indoor
8BHLE-25E
30
19.25 (488.9)
3 (76.2)
17.88 (454.2)
50
Indoor
8BHLE-30E
40
19.25 (488.9)
3 (76.2)
17.88 (454.2)
50
Indoor
8BHLE-40E
50
19.25 (488.9)
3 (76.2)
17.88 (454.2)
50
Indoor
8BHLE-50E
65
19.25 (488.9)
3 (76.2)
17.88 (454.2)
50
Indoor
8BHLE-65E
80
19.25 (488.9)
3 (76.2)
17.88 (454.2)
50
Indoor
8BHLE-80E
100
19.25 (488.9)
3 (76.2)
17.88 (454.2)
50
Indoor
8BHLE-100E
125
19.25 (488.9)
3 (76.2)
17.88 (454.2)
50
Indoor
8BHLE-125E
150
19.25 (488.9)
3 (76.2)
17.88 (454.2)
50
Indoor
8BHLE-150E
175
19.25 (488.9)
3 (76.2)
17.88 (454.2)
50
Indoor
8BHLE-175E
200
19.25 (488.9)
3 (76.2)
17.88 (454.2)
50
Indoor
8BHLE-200E
250
19.25 (488.9)
3 (76.2)
17.88 (454.2)
50
Indoor
8BHLE-250E
300
19.25 (488.9)
3 (76.2)
17.88 (454.2)
50
Indoor
8BHLE-300E
350
19.25 (488.9)
3 (76.2)
17.88 (454.2)
50
Indoor
8BHLE-350E
Amp rating
Number of
barrels
Installation
location
Catalog
number
Overall length
Diameter
Hole centers
Interrupting
rating kA
(RMS Sym.)
Number of
barrels
Installation
location
Catalog
number
8HCL-65E
65
22.5 (571.5)
3 (76.2)
N/A
50
Indoor/outdoor
80
22.5 (571.5)
3 (76.2)
N/A
50
Indoor/outdoor
8HCL-80E
100
22.5 (571.5)
3 (76.2)
N/A
50
Indoor/outdoor
8HCL-100E
125
22.5 (571.5)
3 (76.2)
N/A
50
Indoor/outdoor
8HCL-125E
150
22.5 (571.5)
3 (76.2)
N/A
50
Indoor/outdoor
8HCL-150E
175
22.5 (571.5)
3 (76.2)
N/A
50
Indoor/outdoor
8HCL-175E
200
22.5 (571.5)
3 (76.2)
N/A
50
Indoor/outdoor
8HCL-200E
250
22.5 (571.5)
3 (76.2)
N/A
50
Indoor/outdoor
8HCL-250E
300
22.5 (571.5)
3 (76.2)
N/A
50
Indoor/outdoor
8HCL-300E
350
22.5 (571.5)
3 (76.2)
N/A
50
Indoor/outdoor
8HCL-350E
5-14
1007July 2015
Eaton.com/bussmannseries
Current-limiting
Ratings*:
Volts 15.5kV
Amps 10 to 300A
Agency information:
Description:
Recommended fuseclips:
Catalog symbols:
General purpose
Description
Fuse
diameter in (mm)
Catalog
number
Enclosed fuseclip
2 (51)
A3354710*
Enclosed fuseclip
3 (76)
A3354730*
Open fuseclip
3 (76)
1A0065
3 (76)
9078A67G04
MV155F_
Amp rating
Fuse
mounting
type
Voltage
BIL (kV)
Diameter
Clip center
Length
Mounting
(including live parts, end fittings)*
Porcelain insulator
Glass-polyester
insulator
Live parts
(including
end fittings)
End fittings
(disconnect
only)
CLE
15E25E
Single barrel
Disconnect
10E-D25E-D
30E150E
Single barrel
175E300E
Double barrel
Non-disconnect
Disconnect
95
15CLE-PNM-C
15CLE-GNM-C
CLE-NL-C
110
15CLE-HPNM-C
CLE-NL-C
15CLE-PDM-C
15CLE-GDM-C
CLE-DL-C
CLE-DF-C
110
15CLE-HPDM-C
CLE-DL-C
CLE-DF-C
95
15CLE-PNM-D
15CLE-GNM-D
CLE-NL-D
95
110
95
2 (51)
3 (76)
20 (508)
20 (508)
21.5 (546)
23.9 (607)
15CLE-HPM-D
CLE-NL-D
15CLE-PDM-D
15CLE-GNM-D
CLE-DL-D
CLE-DF-D
CLE-DF-D
110
15CLE-HPDM-D
CLE-DL-D
Non-disconnect
110
15CLE-PNM-E
CLE-NL-E
Disconnect
110
15CLE-PDM-E
CLE-DL-E
CLE-DF-E
15HLE-PNM-D
15HLE-GNM-D
CLE-NL-D
15HLE-PDM-D
15HLE-GDM-D
CLE-DL-D
3 (76)
20 (508)
23.9 (607)
HLE
10E-125E
Single barrel
Non-disconnect
95
Disconnect
95
150E250E
Double barrel
Non-disconnect
95
Disconnect
95
3 (76)
15 (381)
18.9 (480)
3 (76)
15 (381)
18.9 (480)
CLE-DF-D
15HLE-PNM-E
CLE-NL-E
15HLE-PDM-E
CLE-DL-E
CLE-DF-E
LHLE
65E150E
Single barrel
Non-disconnect
Not available
Not available
CLE-NL-D
Disconnect
Not available
Not available
CLE-DL-D
CLE-DF-D
175E300E
Double barrel
Non-disconnect
Not available
Not available
CLE-NL-E
Disconnect
Not available
Not available
CLE-DL-E
CLE-DF-E
3 (76)
3 (76)
18 (457)
18 (457)
20.53 (521)
20.53 (521)
3.31
(84.1)
B
B
A
BUSSMANN SERIES FULL LINE CATALOG
1007July 2015
Eaton.com/bussmannseries
5-15
Medium voltage
fuses
Non-disconnect
Diameter
B
Clip centers
C
10
23.9 (607)
3 (76)
20 (508)
15
21.5 (546)
2 (51)
20 (508)
Amp rating
Interrupting
rating kA
(RMS Sym.)
Number of
barrels
Installation
location
Catalog
number
63
Indoor/outdoor
15CLE-10E-D
31.5
Indoor
15CLE-15E*
15
23.9 (607)
3 (76)
20 (508)
63
Indoor/outdoor
15CLE-15E-D
20
21.5 (546)
2 (51)
20 (508)
31.5
Indoor
15CLE-20E*
20
23.9 (607)
3 (76)
20 (508)
63
Indoor/outdoor
15CLE-20E-D
25
21.5 (546)
2 (51)
20 (508)
31.5
Indoor
15CLE-25E*
25
23.9 (607)
3 (76)
20 (508)
63
Indoor/outdoor
15CLE-25E-D
30
23.9 (607)
3 (76)
20 (508)
63
Indoor/outdoor
15CLE-30E
40
23.9 (607)
3 (76)
20 (508)
63
Indoor/outdoor
15CLE-40E
50
23.9 (607)
3 (76)
20 (508)
63
Indoor/outdoor
15CLE-50E
65
23.9 (607)
3 (76)
20 (508)
63
Indoor/outdoor
15CLE-65E
80
23.9 (607)
3 (76)
20 (508)
63
Indoor/outdoor
15CLE-80E
100
23.9 (607)
3 (76)
20 (508)
63
Indoor/outdoor
15CLE-100E
125
23.9 (607)
3 (76)
20 (508)
63
Indoor/outdoor
15CLE-125E
150
23.9 (607)
3 (76)
20 (508)
63
Indoor/outdoor
15CLE-150E
175
23.9 (607)
3 (76)
20 (508)
63
Indoor/outdoor
15CLE-175E
200
23.9 (607)
3 (76)
20 (508)
63
Indoor/outdoor
15CLE-200E
250
23.9 (607)
3 (76)
20 (508)
63
Indoor/outdoor
15CLE-250E
300
23.9 (607)
3 (76)
20 (508)
63
Indoor/outdoor
15CLE-300E
10
18.9 (480)
3 (76)
15 (381)
63
Indoor/outdoor
15HLE-10E
15
18.9 (480)
3 (76)
15 (381)
63
Indoor/outdoor
15HLE-15E
20
18.9 (480)
3 (76)
15 (381)
63
Indoor/outdoor
15HLE-20E
25
18.9 (480)
3 (76)
15 (381)
63
Indoor/outdoor
15HLE-25E
30
18.9 (480)
3 (76)
15 (381)
63
Indoor/outdoor
15HLE-30E
40
18.9 (480)
3 (76)
15 (381)
63
Indoor/outdoor
15HLE-40E
50
18.9 (480)
3 (76)
15 (381)
63
Indoor/outdoor
15HLE-50E
65
18.9 (480)
3 (76)
15 (381)
63
Indoor/outdoor
15HLE-65E
80
18.9 (480)
3 (76)
15 (381)
63
Indoor/outdoor
15HLE-80E
100
18.9 (480)
3 (76)
15 (381)
63
Indoor/outdoor
15HLE-100E
125
18.9 (480)
3 (76)
15 (381)
63
Indoor/outdoor
15HLE-125E
150
18.9 (480)
3 (76)
15 (381)
63
Indoor/outdoor
15HLE-150E
175
18.9 (480)
3 (76)
15 (381)
63
Indoor/outdoor
15HLE-175E
200
18.9 (480)
3 (76)
15 (381)
63
Indoor/outdoor
15HLE-200E
250
18.9 (480)
3 (76)
15 (381)
63
Indoor/outdoor
15HLE-250E
15LHLE-65E
20.5 (521)
3 (76)
18 (457)
50
Indoor/outdoor
80
20.5 (521)
3 (76)
18 (457)
50
Indoor/outdoor
15LHLE-80E
100
20.5 (521)
3 (76)
18 (457)
50
Indoor/outdoor
15LHLE-100E
125
20.5 (521)
3 (76)
18 (457)
50
Indoor/outdoor
15LHLE-125E
150
20.5 (521)
3 (76)
18 (457)
50
Indoor/outdoor
15LHLE-150E
175
20.5 (521)
3 (76)
18 (457)
50
Indoor/outdoor
15LHLE-175E
200
20.5 (521)
3 (76)
18 (457)
50
Indoor/outdoor
15LHLE-200E
250
20.5 (521)
3 (76)
18 (457)
50
Indoor/outdoor
15LHLE-250E
300
20.5 (521)
3 (76)
18 (457)
50
Indoor/outdoor
15LHLE-300E
1007July 2015
Eaton.com/bussmannseries
Current-limiting
Diameter B
Clip centers C
18.7 (475)
2 (51)
15 (381)
50
Indoor
MV155F1CBX5E
18.7 (475)
2 (51)
15 (381)
50
Indoor
MV155F1CBX7E
10
18.7 (475)
2 (51)
15 (381)
50
Indoor
MV155F1CBX10E
10
18.7 (475)
3 (76)
15 (381)
50
Indoor
MV155F1DBX10E
15
18.7 (475)
2 (51)
15 (381)
50
Indoor
MV155F1CBX15E
15
18.7 (475)
3 (76)
15 (381)
50
Indoor
MV155F1DBX15E
20
18.7 (475)
2 (51)
15 (381)
50
Indoor
MV155F1CBX20E
20
18.7 (475)
3 (76)
15 (381)
50
Indoor
MV155F1DBX20E
25
18.7 (475)
2 (51)
15 (381)
50
Indoor
MV155F1CBX25E
25
18.7 (475)
3 (76)
15 (381)
50
Indoor
MV155F1DBX25E
30
18.7 (475)
2 (51)
15 (381)
50
Indoor
MV155F1CBX30E
30
18.7 (475)
3 (76)
15 (381)
50
Indoor
MV155F1DBX30E
40
18.7 (475)
3 (76)
15 (381)
50
Indoor
MV155F1DBX40E
50
18.7 (475)
3 (76)
15 (381)
50
Indoor
MV155F1DBX50E
65
18.7 (475)
3 (76)
15 (381)
50
Indoor
MV155F1DBX65E
65
21.7 (551)
3 (76)
18 (457)
50
Indoor
MV155F1DCX65E
80
18.7 (475)
3 (76)
15 (381)
50
Indoor
MV155F1DBX80E
80
21.7 (551)
3 (76)
18 (457)
50
Indoor
MV155F1DCX80E
100
18.7 (475)
3 (76)
15 (381)
50
Indoor
MV155F1DBX100E
100
21.7 (551)
3 (76)
18 (457)
50
Indoor
MV155F1DCX100E
125
18.7 (475)
3 (76)
15 (381)
50
Indoor
MV155F2DBX125E
125
21.7 (551)
3 (76)
18 (457)
50
Indoor
MV155F2DCX125E
150
18.7 (475)
3 (76)
15 (381)
50
Indoor
MV155F2DBX150E
150
21.7 (551)
3 (76)
18 (457)
50
Indoor
MV155F2DCX150E
175
18.7 (475)
3 (76)
15 (381)
50
Indoor
MV155F2DBX175E
175
21.7 (551)
3 (76)
18 (457)
50
Indoor
MV155F2DCX175E
200
18.7 (475)
3 (76)
15 (381)
50
Indoor
MV155F2DBX200E
200
21.7 (551)
3 (76)
18 (457)
50
Indoor
MV155F2DCX200E
Number of
barrels
Installation
location
Catalog number
1007July 2015
Eaton.com/bussmannseries
5-17
Medium voltage
fuses
Amp rating
Interrupting rating kA
(RMS Sym.)
Current-limiting
HCL
Catalog symbols:
Indicator*
0.5 (12.7)
Ratings*:
Volts 15.5kV
Amps 10 to 300A
4.31 (109.5)
* See catalog number tables for voltages, ampacities and interrupting ratings by
catalog number.
1.25
(31.8)
1.25
(31.8)
Agency information:
7.94 (201.7)
Dimensions - in (mm)
BHLE
2.12
(53.8)
A
Indicator to be
located here
3.31
(84.1)
2.12
(53.8)
C
A
0.25
(6.4)
1007July 2015
Eaton.com/bussmannseries
Current-limiting
Length
A
Diameter
B
Hole centers
C
Interrupting
rating kA
(RMS Sym.)
Number of
barrels
Installation
location
Catalog number
22.2 (563)
3 (76)
20.9 (531)
63
Indoor/outdoor
15BHLE-10E
15
22.2 (563)
3 (76)
20.9 (531)
63
Indoor/outdoor
15BHLE-15E
20
22.2 (563)
3 (76)
20.9 (531)
63
Indoor/outdoor
15BHLE-20E
25
22.2 (563)
3 (76)
20.9 (531)
63
Indoor/outdoor
15BHLE-25E
30
22.2 (563)
3 (76)
20.9 (531)
63
Indoor/outdoor
15BHLE-30E
40
22.2 (563)
3 (76)
20.9 (531)
63
Indoor/outdoor
15BHLE-40E
50
22.2 (563)
3 (76)
20.9 (531)
63
Indoor/outdoor
15BHLE-50E
65
22.2 (563)
3 (76)
20.9 (531)
63
Indoor/outdoor
15BHLE-65E
80
22.2 (563)
3 (76)
20.9 (531)
63
Indoor/outdoor
15BHLE-80E
100
22.2 (563)
3 (76)
20.9 (531)
63
Indoor/outdoor
15BHLE-100E
125
22.2 (563)
3 (76)
20.9 (531)
63
Indoor/outdoor
15BHLE-125E
150
22.2 (563)
3 (76)
20.9 (531)
63
Indoor/outdoor
15BHLE-150E
175
22.2 (563)
3 (76)
20.9 (531)
63
Indoor/outdoor
15BHLE-175E
200
22.2 (563)
3 (76)
20.9 (531)
63
Indoor/outdoor
15BHLE-200E
250
22.2 (563)
3 (76)
20.9 (531)
63
Indoor/outdoor
15BHLE-250E
300
25.1 (637)
3 (76)
23.7 (602)
50
Indoor
15BHCL-300E
400
25.1 (637)
3 (76)
23.7 (602)
50
Indoor
15BHCL-400E
HCL clip-lock
22.8 (579)
3 (76)
N/A
63
Indoor
15HCL-10E
15
22.8 (579)
3 (76)
N/A
63
Indoor
15HCL-15E
20
22.8 (579)
3 (76)
N/A
63
Indoor
15HCL-20E
25
22.8 (579)
3 (76)
N/A
63
Indoor
15HCL-25E
30
22.8 (579)
3 (76)
N/A
63
Indoor
15HCL-30E
40
22.8 (579)
3 (76)
N/A
63
Indoor
15HCL-40E
50
22.8 (579)
3 (76)
N/A
63
Indoor
15HCL-50E
65
22.8 (579)
3 (76)
N/A
50
Indoor
15HCL-65E
80
22.8 (579)
3 (76)
N/A
50
Indoor
15HCL-80E
100
22.8 (579)
3 (76)
N/A
50
Indoor
15HCL-100E
125
22.8 (579)
3 (76)
N/A
50
Indoor
15HCL-125E
150
22.8 (579)
3 (76)
N/A
50
Indoor
15HCL-150E
200
22.8 (579)
3 (76)
N/A
50
Indoor
15HCL-200E
250
22.8 (579)
3 (76)
N/A
50
Indoor
15HCL-250E
300
22.8 (579)
3 (76)
N/A
50
Indoor
15HCL-300E
Medium voltage
fuses
10
1007July 2015
Eaton.com/bussmannseries
5-19
Current-limiting
Ratings:
Volts
2.4kV (nominal)
Amps 25-450A
Interrupting ratings
50kA Sym
80kA Asym
Agency information:
Description:
Dimensions - in [mm]
Catalog symbols:
Construction
Code-(amps)R Construction
2CLS-25
2ACLS-25
JCK-_R
Standard (2R-24R)
JCK-A-_R
2HCLS-_R
2BCLS-_R
Bolt-on (25A/2R-24R)
Dimension
Amp
range
Standard short
25-230A
10.8 (274)
3 (76)
3 (76)
390-450A
10.8 (274)
3 (76)
3 (76)
3.3 (84)
AMPGARD
Hookeye*
70-230A
10.8 (274)
3 (76)
3 (76.
390-450A
10.8 (274)
3 (76)
3 (76)
3.3 (84)
25-230A
19.2 (488)
17.9 (455)
3 (76)
390-450A
19.2 (488)
17.9 (455)
3 (76)
3.3 (84)
Bolt-on
Description
Fuseclips
25-230A
25-450A
Gripping tab
for Hookeye
constructions
Cat. No.
3 Enclosed fuseclip*
A3354730
3 Open fuseclip
1A0065
9078A67G04
Indicator
C
B
Fuse holders
Non-disconnect holder, porcelain
25-230A
Single barrel
390-450A
Double barrel
Bolt-on
2CLE-PNM-D
2CLE-GNM-D
2CLE-PDM-D
2CLE-GDM-E
2CLE-PNM-E
2CLE-GNM-E
2CLE-PDM-E
2CLE-GDM-E
Indicator
D
C
2.12
[53.8]
3.0
[76.2]
B
A
3.0
[76.2]
R
Designation
AMPGARD Hookeye
Standard
Regular
Hermetically sealed
Bolt-on
Number
of barrels
25
2CLS-25* (90)
2ACLS-25* (90)
2HCLS-25* (90)
2BCLS-25* (90)
70
2R
JCK-2R (165)
JCK-A-2R (165)
2HCLS-2R (170)
2BCLS-2R (170)
100
3R
JCK-3R (220)
JCK-A-3R (220)
2HCLS-3R (245)
2BCLS-3R (245)
130
4R
JCK-4R (320)
JCK-A-4R (320)
2HCLS-4R (340)
2BCLS-4R (340)
150
5R
JCK-5R (410)
JCK-A-5R (410)
2HCLS-5R (430)
2BCLS-5R (430)
170
6R
JCK-6R (480)
JCK-A-6R (480)
2HCLS-6R (500)
2BCLS-6R (500)
200
9R
JCK-9R (720)
JCK-A-9R (720)
2HCLS-200* (1000)
2BCLS-9R (1000)
230
12R
JCK-12R (970)
JCK-A-12R (970)
2HCLS-230* (1250)
2BCLS-12R (1250)
390
18R
JCK-18R (1430)
JCK-A-18R (1430)
2HCLS-390* (1700)
2BCLS-18R (1700)
450
24R
JCK-24R (1880)
JCK-A-24R (1880)
2HCLS-24R (2100)
2BCLS-24R (2100)
*
5-20
1007July 2015
Eaton.com/bussmannseries
Current-limiting
4.8kV
Dimensions - in [mm]
Catalog symbols:
Code-(amps)R Construction
Dimension
Amp
range
Construction
JCL-_R
30-230A
15.9 (404)
3 (76)
3 (76)
5LCLS-_R
Standard short
390-450A
15.9 (404)
3 (76)
3 (76)
3.3 (84)
Standard long
70-230A
17.9 (455)
3 (76)
3 (76)
390-450A
17.9 (455)
3 (76)
3 (76)
3.3 (84)
AMPGARD
Hookeye*
30-230A
15.9 (404)
3 (76)
3 (76)
390-450A
15.9 (404)
3 (76)
3 (76)
3.3 (84)
30-230A
19.2 (488)
17.9 (455)
3 (76)
390-450A
19.2 (488)
17.9 (455)
3 (76)
3.3 (84)
5CLS-30
JCL-A-_R
5ACLS-30
5HCLS-30
5HCLS-_R
5BCLS-30
Bolt-on (30A)
5BCLS-_R
Bolt-on
Ratings:
Volts
4.8kV (nominal)
Amps 30-450A
Interrupting ratings
50kA Sym
80kA Asym
Agency information:
Gripping tab
for Hookeye
constructions
BIL
(kV)
Description
30-450A
Bolt-on
3 Enclosed fuseclip*
A3354730
3 Open fuseclip
1A0065
9078A67G04
60
5HLE-PNM-D
60
5HLE-GNM-D
60
5HLE-PDM-D
60
5HLE-GDM-D
60
5HLE-PNM-E
60
5HLE-GNM-E
60
5HLE-PDM-E
60
5HLE-GDM-E
60
5CLE-PNM-D
60
5CLE-GNM-D
60
5CLE-PDM-D
60
5CLE-GDM-D
75
8CLE-PDM-D
75
8CLE-GDM-D
60
5CLE-PDM-E
60
5CLE-GDM-E
30-230A
Single barrel
390-450A
Double barrel
Cat. No.
Fuseclips
30-230A
Medium voltage
fuses
Indicator
Indicator
D
C
2.12
[53.8]
3.0
[76.2]
3.0
[76.2]
B
A
70-230A
Single barrel
390-450A
Double Barrel
1007July 2015
Eaton.com/bussmannseries
5-21
Current-limiting
R
Designation
AMPGARD Hookeye
Standard - short
Standard - long
Regular
Hermetically sealed
Bolt-on
Number
of barrels
30
5CLS-30* (95)
5ACLS-30* (95)
5HCLS-30* (95)
5BCLS-30* (95)
70
2R
JCL-2R (165)
5LCLS-2R (165)
JCL-A-2R
5HCLS-2R (180)
5BCLS-2R (180)
100
3R
JCL-3R (220)
5LCLS-3R (220)
JCL-A-3R
5HCLS-3R (270)
5BCLS-3R (270)
130
4R
JCL-4R (320)
5LCLS-4R (320)
JCL-A-4R
5HCLS-4R (350)
5BCLS-4R (350)
150
5R
JCL-5R (410)
5LCLS-5R (410)
JCL-A-5R
5HCLS-5R (450)
5BCLS-5R (450)
170
6R
JCL-6R (480)
5LCLS-6R (480)
JCL-A-6R
5HCLS-6R (540)
5BCLS-6R (540)
200
9R
JCL-9R (720)
5LCLS-9R (720)
JCL-A-9R
5HCLS-9R (700)
5BCLS-9R (700)
230
12R
JCL-12R (970)
5LCLS-12R (970)
JCL-A-12R
5HCLS-12R (1000)
5BCLS-12R (1000)
390
18R
JCL-18R (1430)
5LCLS-18R (1430)
JCL-A-18R
5HCLS-18R (1450)
5BCLS-18R (1450)
450
24R
JCL-24R (1880)
5LCLS-24R (1880)
JCL-A-24R
5HCLS-24R (2000)
5BCLS-24R (2000)
600
32R
5BCLS-32R (2600)
650
36R
5BCLS-36R (3000)
800
44R
5BCLS-44R (3250)
5-22
1007July 2015
Eaton.com/bussmannseries
Current-limiting
Dimensions - in [mm]
Construction
Code-(amps)R
Construction
8CLS-_R
7CLS-_R
8ACLS-_R
7ACLS-_R
7BCLS-_R
Standard
Dimension
Amp
range
70-230A
15.8 (401)
3 (76)
3 (76)
3.3 (84)
390-450A
15.8 (401)
3 (76)
3 (76)
AMPGARD
Hookeye
70-230A
15.8 (401)
3 (76)
3 (76)
390-450A
15.8 (401)
3 (76)
3 (76)
3.3 (84)
70-230A
19.2 (488)
17.9 (455)
3 (76)
Bolt-on
390-650A
19.2 (488)
17.9 (455)
3 (76)
3.3 (84)
800A
19.2 (488)
17.9 (455)
4 (102)
3.3 (84)
Ratings:
Volts
7.2kV (nominal)
Amps 25-450A
Interrupting ratings
50kA Sym
80kA Asym
Gripping tab
for Hookeye
constructions
D
C
Indicator
BIL
(kV)
Description
Cat. No.
Bolt-on
Fuseclips
70-450A
3 Enclosed fuseclip*
A3354730
3 Open fuseclip
1A0065
9078A67G04
75
8HLE-PNM-D
75
8HLE-GNM-D
75
8HLE-PDM-D
75
8HLE-GDM-D
75
8HLE-PNM-E
75
8HLE-GNM-E
75
8HLE-PDM-E
75
8HLE-GDM-E
EFGHI
E = 3 [76.2]
F = 2.5 [63.5]
G = 2.04 [51.81
H = 0.96 [24.4]
I= 0.5 [12.7]
70-230A
Single barrel
390-450A
Double barrel
Medium voltage
fuses
70-230A
Indicator
D
C
2.12
[53.8]
B
A
3.0
[76.2]
3.0
[76.2]
Amp rating
R
Designation
AMPGARD Hookeye
Bolt-on
Number
of barrels
70
2R
8CLS-2R (160)
8ACLS-2R (160)
7BCLS-2R (160)
100
3R
8CLS-3R (250)
8ACLS-3R (250)
7BCLS-3R (250)
130
4R
8CLS-4R (325)
8ACLS-4R (325)
7BCLS-4R (325)
150
5R
8CLS-5R (390)
8ACLS-5R (390)
7BCLS-5R (390)
170
6R
8CLS-6R (500)
8ACLS-6R (500)
7BCLS-6R (500)
200
9R
7CLS-9R (750)
7ACLS-9R (750)
7BCLS-9R (750)
230
12R
7CLS-12R (1000)
7ACLS-12R (1000)
7BCLS-12R (1000)
390
18R
7CLS-18R (1450)
7ACLS-18R (1450)
7BCLS-18R (1450)
450
24R
7CLS-24R (2500)
7ACLS-24R (2500)
7BCLS-24R (2500)
650
36R
7BCLS-36R (3000)
800
44R
7BCLS-44R (3250)
1007July 2015
Eaton.com/bussmannseries
5-23
Current-limiting
Ratings*:
PT E-Rated fuses
Agency information:
Description:
2.475kV
2NCLPT-_
3.6kV
3.6ABCNA_
3.6ABWNA_
3.6CAV_
5.5kV
JCW-_
5CLPT-_E
5NCLPT-_E
5NCLPT-_E-A
5.5ABWNA_E
5.5AMWNA_E
5.5CAV_E
5.5CAVH_E
7.2kV
7.2ABWNA_
7.2ABCNA_
7.2AMWNA_E
7.2CAV_
8.3kV
8CLPT-_E-A
8CLPT-_E-B
8NCLPT-_E
8NCLPT-_E-A
8NCLPT-_E-B
12kV
12ABCNA_
12CAV_
15.5kV
15CLPT-_E
15NCLPT-_E-A
15NCLPT-_E-B
15.5CAV_E
15.5CAVH_E
17.5kV
17.5ABGNA_
17.5CAV_
24kV
24ABGNA_
24CAV_
25.5kV
25CLPT-_E
36kV
36ABGNA_
36CAV_
38kV
38CAV_E
38CAVH_E
38CLPT-_E
B
A
Recommended fuseclips:
Description
Cat. No.
1A1837
A3354705
1A0835
Indicator
1007July 2015
Eaton.com/bussmannseries
Current-limiting
Length
A
Diameter
B
Indicating
Non-indicating
0.25
2NCLPT-.25E (63)
0.5
2NCLPT-.5E (63)
2NCLPT-1E (40)
2NCLPT-2E (40)
2NCLPT-5E (25)
4.5 (114)
0.8 (20)
3.9 (99)
Recommended
fuseclip
1A1837
Cat. No.
1A1837
PTFB-2500-JCD
Length
A
Diameter
B
Indicating
Non-indicating
Recommended
fuseclip
1A1837
8.7 (221)
1.6 (41)
7.6 (193)
3.6CAV2 (50)
5.6 (142)
1 (25)
4.4 (112)
3.6ABWNA3.15 (50)
3.15
7.7 (195)
1 (25)
6.5 (165)
3.6ABCNA3.15 (50)
6.3
5.6 (142)
1 (25)
4.4 (112)
3.6ABWNA6.3 (50)
3.6ABCNA6.3 (50)
3.6ABCNA10 (50)
6.3
10
7.7 (195)
1 (25)
6.5 (165)
Medium voltage
fuses
2
3.15
A3354705
1007July 2015
Eaton.com/bussmannseries
5-25
Current-limiting
Length
A
Diameter
B
0.5
5.6 (142)
0.8 (20)
0.5
5.6 (142)
1 (25)
0.5
7.4 (188)
1.6 (41)
0.5
9.5 (241)
Clip centers
C
Indicating
Non-indicating
Recommended
fuseclip
4.8 (122)
5.5AMWNA0.5E (50)
1A1837
4.4 (112)
5.5ABWNA0.5E (50)
A3354705
6.2 (157)
5.5CAVH0.5E (63)
JCW-1/2E (40)
1.6 (41)
8.1 (206)
5CLPT-.5E (80)
5NCLPT-.5E-A (63)
5.6 (142)
1 (25)
4.4 (112)
5.5ABWNA1E (50)
A3354705
5.6 (142)
0.8 (20)
4.8 (122)
5.5AMWNA1.0E (50)
1A1837
7.4 (188)
1.6 (41)
6.2 (157)
5.5CAVH1E (63)
JCW-1E (40)
9.5 (241)
1.6 (41)
8.1 (206)
5CLPT-1E (80)
5NCLPT-1E-A (63)
1.5
9.5 (241)
1.6 (41)
8.1 (206)
5CLPT-1.5E (80)
5.6 (142)
1 (25)
4.4 (112)
5.5ABWNA2E (50)
A3354705
5.6 (142)
0.8 (20)
4.8 (122)
5.5AMWNA2.0E (50)
1A1837
7.4 (188)
1.6 (41)
6.2 (157)
5.5CAVH2E (63)
JCW-2E (40)
1A0835
5.6 (142)
1 (25)
4.4 (112)
5.5ABWNA3E (50)
A3354705
5.6 (142)
0.8 (20)
4.8 (122)
5.5AMWNA3.0E (50)
1A1837
9.5 (241)
1.6 (41)
8.1 (206)
5CLPT-3E (80)
1A0835
7.4 (188)
1.6 (41)
6.2 (157)
5.6 (142)
0.8 (20)
4.8 (122)
7.3 (185)
1.6 (41)
5.9 (150)
9.5 (241)
1.6 (41)
8.1 (206)
5.6 (142)
1 (25)
5.6 (142)
1A0835
1A0835
1A0835
JCW-3E (40)
1A0835
5.5AMWNA4.0E (50)
1A1837
JCW-4E (40)
1A0835
5CLPT-5E (80)
1A0835
4.4 (112)
5.5ABWNA5E (50)
A3354705
0.8 (20)
4.8 (122)
5.5AMWNA5.0E (50)
1A1837
7.3 (185)
1.6 (41)
5.9 (150)
JCW-5E (40)
1A0835
10
9.5 (241)
1.6 (41)
8.1 (206)
5CLPT-10E (80)
15
7.4 (188)
1.6 (41)
6.2 (157)
5.5CAV15E (63)
1A0835
Amp rating
Fuse
mounting
type**
Catalog number
BIL
(kV)
Glass-polyester insulator
Non-disconnect
60
5CLPT-PNM-A
5CLPT-GNM-A
CLPT-NL
Disconnect
60
5CLPT-PDM-A
5CLPT-GDM-A
CLPT-DL
CLPT-DF
1007July 2015
Eaton.com/bussmannseries
Current-limiting
Amp rating
Length
A
Diameter
B
Clip centers
C
0.5
5.6 (142)
0.8 (20)
5.6 (142)
0.8 (20)
5.6 (142)
Recommended
fuseclip
Indicating
Non-indicating
4.8 (122)
7.2AMWNA0.5E (50)
4.8 (122)
7.2AMWNA1.0E (50)
0.8 (20)
4.8 (122)
7.2AMWNA2.0E (50)
8.7 (221)
1.6 (41)
7.5 (190)
7.2CAV2 (63)
1A0835
5.6 (142)
0.8 (20)
4.8 (122)
7.2AMWNA3.0E (50)
1A1837
3.15
5.6 (142)
1 (25.4)
4.4 (112)
7.2ABWNA3.15 (45)
3.15
7.7 (195)
1 (25.4)
6.5 (165)
7.2ABCNA3.15 (45)
5.6 (142)
0.8 (20)
4.8 (122)
7.2AMWNA4.0E (50)
8.7 (221)
1.6 (41)
7.5 (190)
7.2CAV4 (63)
1A0835
5.6 (142)
0.8 (20)
4.8 (122)
7.2AMWNA5E (50)
1A1837
8.7 (221)
1.6 (41)
7.5 (190)
7.2CAV6 (63)
1A0835
6.3
5.6 (142)
1 (25.4)
4.4 (112)
7.2ABWNA6.3 (45)
6.3
7.7 (195)
1 (25.4)
6.5 (165)
7.2ABCNA6.3 (45)
10
8.7 (221)
1.6 (41)
7.5 (190)
7.2CAV10 (63)
1A1837
A3354705
1A1837
A3354705
1A0835
Diameter
B
Clip centers
C
Non-indicating
Recommended
fuseclip
0.5
9.5 (241)
1.6 (41)
8.1 (206)
8CLPT-.5E-A (80)
5 (127)
1.1 (28)
8NCLPT-.5E-A (50)
1A0835
4 (102)
8NCLPT-1E (50)
9.5 (241)
1.6 (41)
A3354705
8.1 (206)
8NCLPT-1E-A (50)
1A0835
1A1837
Indicating
8 (203)
0.8 (20)
7.2 (183)
8NCLPT-2E (25)
9.5 (241)
1.6 (41)
8.1 (206)
8NCLPT-2E-A (50)
12.9 (328)
1.6 (41)
11.5 (292)
8CLPT-3E-B (80)
8NCLPT-3E-B (50)
Medium voltage
fuses
Amp rating
Length
A
1A0835
8 (203)
0.8 (20)
7.2 (183)
8NCLPT-4E (25)
1A1837
5 (127)
1.1 (28)
4 (102)
8NCLPT-5E (50)
A3354705
12.9 (328)
1.6 (41)
11.5 (292)
8CLPT-5E-B (50)
8NCLPT-5E-B (50)
10
12.9 (328)
1.6 (41)
11.5 (292)
8CLPT-10E-B (50)
8NCLPT-10E-B (50)
1A0835
0.52
310
Glass-polyester insulator
75
8CLPT-PNM-A
8CLPT-GNM-A
CLPT-NL
75
8CLPT-PDM-A
8CLPT-GDM-A
CLPT-DL
CLPT-DF
Non-disconnect
75
8CLPT-PNM-B
8CLPT-GNM-B
CLPT-NL
Disconnect***
75
8CLPT-PDM-B
8CLPT-GDM-B
CLPT-DL
CLPT-DF
Fuse mounting
type**
BIL
(kV)
Non-disconnect
Disconnect***
*
Refers to 8CLPT and 8NCLPT-A or -B fuses only.
** End fittings supplied only when required.
*** Disconnect mountings provide a means for fuse extraction only. Do not use a disconnect mounting for load switching or fuse removal while energized.
1007July 2015
Eaton.com/bussmannseries
5-27
Current-limiting
Amp rating
Length
A
Diameter
B
Clip centers
C
Indicating
Non-indicating
Recommended
fuseclip
8.7 (221)
1.6 (41)
7.5 (190)
12CAV2 (40)
1A0835
3.15
7.7 (195)
1 (25)
6.5 (165)
12ABCNA3.15 (45)
A3354705
Length
A
Diameter
B
Clip centers
C
0.5
12.9 (328)
1.6 (41)
12.9 (328)
1.6 (41)
12.9 (328)
12.9 (328)
3
3
Amp rating
Indicating
Non-indicating
11.5 (292)
15.5CAVH0.5E (80)
15NCLPT-.5E-A (63)
11.5 (292)
15.5CAVH1E (80)
15NCLPT-1E-A (63)
1.6 (41)
11.5 (292)
15.5CAVH2E (80)
15NCLPT-2E-A (63)
1.6 (41)
11.5 (292)
15.5CAV3E (80)
17.6 (447)
1.6 (41)
16.1 (409)
15NCLPT-3E-B (63)
17.6 (447)
1.6 (41)
16.1 (409)
15CLPT-3E-B (63)
12.9 (328)
1.6 (41)
11.5 (292)
15.5CAV5E (80)
17.6 (447)
1.6 (41)
16.1 (409)
15CLPT-5E-B (80)
15NCLPT-5E-B (63)
12.9 (328)
1.6 (41)
11.5 (292)
15.5CAV7E (80)
10
17.6 (447)
1.6 (41)
16.1 (409)
15CLPT-10E-B (50)
15NCLPT-10E-B (63)
Recommended
fuseclip
1A0835
0.52
310
*
**
Glass-polyester insulator
95
15CLPT-PNM-A
15CLPT-GNM-A
CLPT-NL
Disconnect**
95
15CLPT-PDM-A
15CLPT-GDM-A
CLPT-DL
CLPT-DF
Non-disconnect
95
15CLPT-PNM-B
15CLPT-GNM-B
CLPT-NL
CLPT-DF
Disconnect**
95
15CLPT-PDM-B
15CLPT-GDM-B
CLPT-DL
Fuse mounting
type*
BIL
(kV)
Non-disconnect
Length
A
Diameter
B
Indicating
Non-indicating
17.5CAV2 (40)
17.5CAV4 (40)
17.5CAV6 (40)
17.5CAV10 (40)
8.7 (221)
1.6 (41)
7.5 (190)
10
1007July 2015
Eaton.com/bussmannseries
Recommended
fuseclip
1A0835
Current-limiting
Length
A
Diameter
B
Clip centers
C
13.49 (340)
1.6 (41)
12.2 (310)
2
3
4
Indicating
Non-indicating
24CAV2 (40)
24CAV3 (40)
24CAV4 (40)
Recommended
fuseclip
1A0835
Length
A
Diameter
B
Clip centers
C
Indicating
Non-indicating
0.5
17.6 (447)
1.6 (41)
16.1 (410)
25CLPT-.5E (44)
17.6 (447)
1.6 (41)
16.1 (410)
25CLPT-1E (44)
Recommended
fuseclip
1A0835
Fuse mounting
type*
BIL
(kV)
Glass-polyester insulator
Non-disconnect
150
25CLPT-PNM-A
25CLPT-NL
Disconnect**
150
25CLPT-PDM-A
25CLPT-DL
CLPT-DF
Dimensions - in (mm)
Amp rating
2
4
Length
A
Diameter
B
Clip centers
C
17.3 (439)
1.6 (41)
16.1 (410)
Indicating
Non-indicating
36CAV2 (40)
36CAV4 (40)
Recommended
fuseclip
1A0835
Length
A
Diameter
B
Clip centers
C
Indicating
Recommended
fuseclip
Non-indicating
0.5
17.3 (439)
1.6 (41)
16.1 (409)
38CAVH0.5E (38)
0.5
18.6 (472)
1.6 (41)
17.1 (434)
38CLPT-0.5E (44)
17.3 (439)
1.6 (41)
16.1 (409)
38CAVH1E (38)
17.3 (439)
1.6 (41)
16.1 (409)
38CAVH2E (38)
1A0835
17.3 (439)
1.6 (41)
16.1 (409)
38CAV4E (38)
Fuse mounting
type
Porcelain insulator
Disconnect
Not applicable
Not applicable
25CLPT-NL
CLPT-DF
Non-disconnect
Not applicable
Not applicable
25CLPT-DL
1007July 2015
Eaton.com/bussmannseries
5-29
Medium voltage
fuses
Current-limiting
Fast-acting PT fuses
HVA, HVB,
HVJ, HVL, HVR,
HVT, HVU,
HVW & HVX
Test specifications
Basic catalog
numbers
HVA, HVB, HVJ, HVL
Specifications
Description:
Medium voltage, non-time delay, fast-acting fuses.
Dimensions: See basic catalog numbers table.
Ratings:
Volts: 1-10kV (see basic catalog numbers table)
Amps: 116-10A (see basic catalog numbers table)
Typical applications
Medium voltage instrument protection
Medium voltage circuit protection
Basic catalog
numbers
HVA, HVR
HVB, HVT
HVJ, HVU
HVL, HVX
Fuse block
catalog number
4528
4529
N/A
N/A
Basic
catalog
number
HVA
HVB
HVJ
HVL
HVR
HVW
HVT
HVU
HVX
kV
1
2.5
5
10
1
1.2
2.5
5
10
Amp ratings
1
16, 110, 18, 210, 14, 310, 38, 12,
3
4, 1, 1 12, 2, 3, 4, 6, 10
1
2, 34, 1, 1 12, 2, 3
1
16, 18, 14, 12, 34, 1 12, 2, 4, 6, 10
1
16, 18, 14, 12, 1, 1 12, 2, 3
1
2, 1, 2, 3, 4, 5
1, 2, 3, 4, 5, 8
1
2, 1, 2, 3, 5
1
2, 1, 2, 3, 4, 5
1
2, 1, 3, 5
Maximum S.C.
20kW DC/30kVA AC
20kW DC/30kVA AC
20kW DC/30kVA AC
20kW DC/30kVA AC
kVA-500 AC only
kVA-12,000 AC only
kVA-1250 AC only
kVA-2500 AC only
kVA-5,000 AC only
Dimensions - in (mm)
Diameter
Length
0.41 (10.4)
3 (76.1)
0.41
0.81
0.81
0.41
0.41
0.41
0.81
0.81
Amps
___
1007July 2015
Fuse clip
catalog number
5960
5960
4180
4180
Eaton.com/bussmannseries
(10.4)
(20.6)
(20.6)
(10.4)
(10.4)
(10.4)
(20.6)
(20.6)
4.5 (114.2)
5 (126.9)
10 (254)
3 (76.2)
2.25 (57.1)
4.5 (114.2)
5 (126.9)
10.0 (253.8)
Basic cat.
number
3.6WJON6
3.6WDOH6
3.6WFOH6
3.6WDLSJ
3.6WFLSJ
3.6WDFHO
3.6WFFHO
3.6WKFHO
5.5VFNHA
5.5VKNHA
7.2WFNHO
7.2WKNHO
7.2WFMSJ
7.2WKMSJ
Volts
3.6kV
3.6kV
3.6kV
3.6kV
3.6kV
3.6kV
3.6kV
3.6kV
5.5kV
5.5kV
7.2kV
7.2kV
7.2kV
7.2kV
Breaking
capacity
50kA
50kA
50kA
50kA
50kA
50kA
50kA
50kA
60kA
60kA
40kA
40kA
63kA
63kA
Dimensions - in (mm)
Amp ratings
Length
Diameter
5, 6.3, 10, 16, 20, 25, 31.5, 40, 50
7.56 (192)
1.4 (35.6)
7.56 (192)
2 (50.8)
50, 63, 80, 100, 125
160, 200
7.56 (192)
3 (76.2)
50, 63, 80, 100, 125
11.5 (292.1)
2 (50.8)
160, 200
11.5 (292.1)
3 (76.2)
50, 63, 80, 100, 125
10 (254)
2 (51)
160, 200
10 (254)
3 (76.2)
3 (76.2)
250, 315, 355, 400
10 (254)
2R-6R
15.86 (402.8)
3 (76.2)
9R-24R
15.86 (402.8)
3 (76.2)
25, 31.5, 40, 50, 63, 80, 100, 125, 160 15.86 (402.8)
3 (76.2)
200, 224, 250, 315
15.86 (402.8)
3 (76.2)
25, 31.5, 40, 50, 63, 80, 125, 160
17.40 (442)
3 (76.2)
17.40 (442)
3 (76.2)
200, 224, 250, 315, 355
_____
Dimensional standard
BS 2692 (TA1) Interchangeable with GEC Type K2 PA
BS 2692 (TA1) or DIN 43625
BS 2692 (TA1) or DIN 43625
DIN 43625
DIN 43625
BS 2692 (TA2)
BS 2692 (TA2)
BS 2692 (TA2)
ANSI R-Rated
ANSI R-Rated
BS 2692 (TA4)
BS 2692 (TA4)
DIN 43625
DIN 43625
Amps
___
1007July 2015
Eaton.com/bussmannseries
5-31
Medium voltage
fuses
Table of ratings
Current-limiting
_____
Amps
___
Catalog numbers
kV
3.6
7.2
12
17.5
24
36
Catalog numbers
3.6ADOSJ(amp)
3.6WDOSJ(amp)
3.6WFOSJ(amp)
3.6ADLSJ(amp)
3.6WDLSJ(amp)
3.6WFLSJ(amp)
3.6WKLSJ(amp)
7.2TDLSJ(amp)
7.2TFLSJ(amp)
7.2WKMSJ(amp)
12TDLEJ(amp)
12THLEJ(amp)
12TKLEJ(amp)
12TXLEJ(amp)*
17.5TDLSJ(amp)*
17.5TFLSJ(amp)*
17.5TDMEJ(amp)
17.5THMEJ(amp)
17.5TKMEJ(amp)
24TDMEJ(amp)
24THMEJ(amp)
24TFMEJ(amp)
24TXMEJ(amp)*
36TDQSJ(amp)
36TFQSJ(amp)
36TXQEJ(amp)*
Amp ratings
6.3, 10, 16, 20, 25, 31.5, 40
50, 63, 80, 100, 125
160, 200
25, 40
50, 63, 80, 100, 125
160, 200
250, 315, 400
6.3, 10, 16, 20, 25, 31.5, 40, 50, 63
80, 100, 125, 160
200, 225, 250, 315, 355
6.3, 10, 16, 20, 25, 31.5, 40, 50, 63
80, 100
125
160, 200
6.3, 10, 16, 20, 25, 31.5, 40
50
6.3, 10, 16, 20, 25, 31.5, 40, 50, 63
80, 100
125
6.3, 10, 16, 20, 25, 31.5, 40, 50
63
80, 100*1
1252, 160
3.153, 6.3, 10, 16, 20, 25
31.5, 40, 50
63
IR RMS Sym
40kA
50kA
40kA
63kA
35.5kA
50kA
50kA
31.5kA
35.5kA
20kA
Recommended fuseclips for DIN style fuses 270303, A3354745 see page 120.
*Not compliant with VDE 0670, part 402.
1
-IR RMS Sym is 63kA
2
-IR RMS Sym is 40kA
3
-IR RMS Sym is 20kA
Striker In
Operated Position
Diameter
Dimensions - In (mm)
0.59"
15.0mm
1.77"
45.0mm
5-32
1.02"
1.34"
34.0mm 26.0mm
Length
1007July 2015
Eaton.com/bussmannseries
Typical applications:
Primary side transformer protection
Feeder protection
Capacitor bank protection
Ratings:
Volts: 15 to 72kV
Amps: 1 to 100A
Breaking capacity: depends on voltage but is approximately 8kA
Agency information:
Type T: complies with ANSI C37-42
Type K: complies with ANSI C37-42
Features and benefits
Wide range of options available from 15kV to 72kV in ANSI
T and K characteristics.
Extra rapid option also available.
Packaging:
Up to and including 50A: 25 in a carton
From 60A to 100A: 10 in a carton
To avoid incorrect replacement the fuse links have colour
coded labels:
Pink label: Type XA
Yellow label: Type K
Green label: Type T
Use of application
Expulsion fuse links current ratings should be selected on the
basis of maximum expected transient no damage currents
rather than on full load current. In addition, the selection of
higher current ratings will reduce the possibility of supply
interruption due to transient surges such as those due to
lightning strikes.
Links should be handled with a reasonable degree of care
when installing. Excessively rough handling may damage the
element.
It is normal, under certain fault conditions, for arc
extinguishing material and/or metal particles to be expelled
from the fuse assembly. It is therefore recommended that
reasonable precautions be taken to prevent the installation
being approached by unauthorised persons.
Rated
voltage
(kV)
15
25
46
72
1st letter
Type of current characteristics
2nd letter
Type of termination
Rated current
(A)
1, 2, 3, 4, 5,
T = complies with ANSI C 37-42 requirements for slow B = a fixed NEMA button head link
6, 7.5, 8, 10,
acting T characteristics
U = a universal link, with double tail and slip off 12, 15, 20,
NEMA button head
25, 30, 40,
K = complies with ANSI C 37-42 requirements for fast
50, 60, 65,
D = double tailed link without NEMA button
75, 80, 100
acting K characteristics
head
XA = this type of expulsion fuse link has an extra rapid
BR = as pattern B but the button head is
characteristic. It is suitable for applications where a
attached via a 1/4 UNF thread to allow use of
high degree of system protection is required at the
an extension rod.
expense of discrimination
See outline drawings opposite page for
S = Solid links rated at 100A are also available in both reference
button head and universal versions for fitting into
expulsion fuse carriers where required. These can be
ordered in a similar way using the abbreviation S, e.g.
15SB, etc
1007July 2015
Eaton.com/bussmannseries
5-33
Medium voltage
fuses
15kV
533 (21)
25kV
660 (26)
46kV
787 (31)
72kV
1016 (40)
1-50A
60-100A
5-34
1007July 2015
Eaton.com/bussmannseries
Specifications
Description: Medium
voltage fuses: Type H
(high surge), EEI-NEMA
Type K (fast-acting),
EEI-NEMA Type T
(slow-acting).
Ratings:
Amps: 1-200A
(See catalog
numbers tables)
EEI-NEMA
Type T
(Slow)
FL11T1
FL11T2
FL11T3
FL11T5
FL11T6
FL11T8
FL11T10
FL11T12
FL11T15
FL11T20
FL11T25
FL11T30
FL11T40
FL11T50
FL11T65
FL11T80
FL11T100
FL11T140
FL11T200
Amps
1
2
3
5
6
8
10
12
15
20
25
30
40
50
65
80
100
140
200
Catalog numbers
EEI-NEMA
EEI-NEMA
Type K
Type T
(Fast)
(Slow)
FL3K1
FL3T1
FL3K2
FL3T2
FL3K3
FL3T3
FL3K5
FL3T5
FL3K6
FL3T6
FL3K8
FL3T8
FL3K10
FL3T10
FL3K12
FL3T12
FL3K15
FL3T15
FL3K20
FL3T20
FL3K25
FL3T25
FL3K30
FL3T30
FL3K40
FL3T40
FL3K50
FL3T50
FL3K65
FL3T65
FL3K80
FL3T80
FL3K100
FL3T100
FL3K140
FL3T140
FL3K200
FL3T200
Amps
1
2
3
5
6
8
10
12
15
20
25
30
40
50
65
80
100
140
200
Medium voltage
fuses
Catalog numbers
Type H
EEI-NEMA
(High
Type K
surge)
(Fast)
FL11H1
FL11K1
FL11H2
FL11K2
FL11H3
FL11K3
FL11H5
FL11K5
FL11K6
FL11H8
FL11K8
FL11K10
FL11K12
FL11K15
FL11K20
FL11K25
FL11K30
FL11K40
FL11K50
FL11K65
FL11K80
FL11K100
FL11K140
FL11K200
Catalog numbers
EEI-NEMA
Type K
Amps
FL12K8
8
FL12K10
10
FL12K12
12
FL12K15
15
FL12K25
25
FL12K50
50
1007July 2015
Eaton.com/bussmannseries
5-35
Description
Catalog
number
Enclosed fuseclip
1.77 (45)
3.50 (89)
2.50 (63)
1.77 (45)
Enclosed fuseclip
2 (51)
3.75 (95)
1.98 (50)
2.01 (51)
0.4 (10)
A3354710*
Enclosed fuseclip
3 (76)
4.14 (105)
2.45 (62)
3.01 (76)
0.4 (10)
A3354730*
Open fuseclip
3 (76)
1A0065
3 (76)
9078A67G04
Figure 1
Figure 2
Figure 3
F
E
5-36
1007July 2015
Eaton.com/bussmannseries
Contents
Description
Page
TM
High speed
fuses
1007July 2015
Eaton.com/bussmannseries
6-1
General applications
Rated voltage
Power factor
X
1.0
0.9
0.8
Melting characteristic
Clearing integrals
104
6-2
2
103
6
4
2
102
6
4
2
101
6
4
2
100
6
4
Power losses
101
6
4
2
102
6
4
2
103
6
4
2
104
0.7
Arc voltage
6
4
101
8 102
8 103
1.5
1.0
0.3
0.4
0.5
COS w
103
9
8
7
6
5
4
3
200 300
1.0
Kp
0.8
400
500
Eg
600 660
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
70
Ib
80 90 100%
105
0.3
Eg
1.4
1.2 UL
0.2
0.5
0.4
0.2
0.1
Cut-off current
Time In Seconds
The melting
characteristic
shows the virtual
melting time in
seconds as a
function of the
prospective current
in amps rms. The
fuses are specially
constructed for
short-circuit
protection against
high level fault
currents. Loading
and operation of
the fuse in the noncontinuous/dashed
section of the melt
curve must be
avoided. The curve
can also be read
as the real melting
time as a function
of the RMS value
of the pre-arc current.
104
103
A
B
2 10 2
102
103
104
Prospective Current in Amps RMS
105
106
1007July 2015
Eaton.com/bussmannseries
General applications
that obtainable in the same circuit if that fuse were replaced
with a solid conductor of equal impedance.
A asymmetrical current
B symmetrical current
Parallel connection
Overloads
Frequency of Occurrence
Less than once per month
DC operation
Reduction Factor
1.0
High speed
fuses
Thread
configuration
5
16 18, M8
3
8 16, M10
3
8 24
1
2 13, M12
1
2 20
*1 Nm = 0.7375 lb-ft
0.9
0.8
Reduction of permissible
(IEC cross section)
load current when the
conductor cross section is less than that given in IEC
Publication 269-1 and 4 valid for Bussmann series high
speed fuses.
0.5 0.6
0 .7
0.8
0.9
1.0
Application assistance
1007July 2015
Eaton.com/bussmannseries
6-3
North American
Introduction
General information
Accessories
Fuse bases
Amps
1000-4000
70-1000
35-2500
35-1600
1-1000
5-1200
40-600
35-2000
Amp
range
1-600
1000-4000
70-1000
35-2500
35-1600
1-1000
35-800
5-1200
35-2000
Volts
600
130
150
250
500
600
600
700
1000
Volts
130
150
250
500
600
700
800
1000
AC
X
X
X
X
X
X
6-4
DC
X
X
X
X
X
X
Page
6-5
6-6
6-8
6-10
6-12
6-14
6-15
6-16
6-19
6-21
All Eaton North American style fuses are tested at their rated
voltage. Eaton should be consulted for applications
exceeding those values.
Accessories
1007July 2015
Eaton.com/bussmannseries
DFJ Class J
Specifications
Description: High speed, current-limiting fuse. The
Bussmann series DFJ drive fuse will provide
maximum protection for AC and DC drives and
controllers and meet NEC branch circuit protection
requirements. The drive fuse has the lowest I2t of
any branch circuit fuse to protect power
semiconductor devices that utilize diodes, GTOs,
SCRs and SSRs.
Dimensions: See page 1-5 for Class J dimensions.
Construction: Melamine tube with silver fuse
element.
Ratings:
Volts 600Vac (or less), 450Vdc (or less, 15-600A)
Amps 1-600A
IR 200kA RMS Sym., 100kA DC
Agency information: CE, UL Listed, Std. 248-8, Class J,
Guide JDDZ, File E4273, CSA Certified, Class 1422-02, File
53787.
Features and benefits
Easily coordinated with existing and new variable speed
drives and electric controllers.
Standard Class J dimensions allowing the use of readily
available fuse blocks, holders, and switches.
Allows the lowest let-thru energy of any branch circuit
overcurrent protective device.
Typical applications
Protection of AC and DC drives
Equipment using power semiconductor devices
Catalog
number
DFJ-1
DFJ-2
DFJ-3
DFJ-4
DFJ-5
DFJ-6
DFJ-8
DFJ-12
DFJ-15
DFJ-20
DFJ-25
DFJ-30
DFJ-35
DFJ-40
DFJ-45
DFJ-50
DFJ-60
DFJ-70
DFJ-80
DFJ-90
DFJ-100
DFJ-110
DFJ-125
DFJ-150
DFJ-175
DFJ-200
DFJ-225
DFJ-250
DFJ-300
DFJ-350
DFJ-400
DFJ-450
DFJ-500
DFJ-600
Rated current
RMS amps
1
2
3
4
5
6
8
12
15
20
25
30
35
40
45
50
60
70
80
90
100
110
125
150
175
200
225
250
300
350
400
450
500
600
4
110
8
365
12
610
20
1000
55
1100
90
1900
90
1900
140
2800
290
6000
450
3100
650
4600
1010
7200
1460
10500
1710
9500
3580
20000
5080
28000
6310
35000
9850
54500
11420
51000
17000
74500
23500
103000
38800
170000
62200
272000
44600
270000
79500
480000
138000
830000
Watts
loss
4.1
4.0
4.9
5.5
6.8
8.6
8.6
8.7
8.5
12
13
13
13
17
15
19
23
24
29
30
36
39
40
56
52
57
1007July 2015
Eaton.com/bussmannseries
6-5
North American
Arc voltage
Specifications
Description: North American
style flush-end high speed fuses.
Dimensions: See dimensions
illustrations.
Ratings:
Volts: 130Vac
Amps: 1000-4000A
IR: 200kA RMS Sym.
50kA @130Vdc
Agency information: CE, UL Recognized JFHR2.E91958 on
1000-2000A fuses
Catalog number
FWA-1000AH-2000AH
FWA-2500AH-3000AH
FWA-4000AH
Dimensions - in
Fig.
1
1
2
B
2.0
3.0
3.5
1.5
1.0
0.5
0.15
26
C
1.0
1.5
1.5
65
1.5
Fig. 1: 1000-3000A
104
Catalog
numbers
FWA-1000AH
FWA-1200AH
FWA-1500AH
FWA-2000AH
FWA-2500AH
FWA-3000AH
FWA-4000AH
Eg
130
Thread depth
Tapped 38-24 x 12
Tapped 12-20 x 12
Tapped 12-20 x 12
1.875
Typical applications
DC common bus
DC drives
Power converters/rectifiers
Reduced voltage starters
100
1007July 2015
Eaton.com/bussmannseries
Eg
150
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
70
1.0
Kp
0.8
50
Fig. 2: 4000A
1.875
100
Electrical characteristics
I2t (A2 Sec)
Rated current
Clearing
RMS-amps
Pre-arc
at 130V
1000
170000
460000
1200
270000
730000
1500
520000
1400000
2000
860000
2400000
2500
1500000
4100000
3000
2100000
5700000
4000
3400000
9200000
Catalog numbers
0.3
0.2
200
Power losses
Electrical characteristics
Total Clearing I2t
300
UL
Ib
80 90 100%
Watts
loss
60
70
78
108
130
150
257
FWA-1000AH
FWA-1200AH
FWA-1500AH
FWA-2000AH
FWA-2500AH
FWA-3000AH
FWA-4000AH
2
102
6
4
2
101
6
4
2
10
6
4
2
101
6
4
2
102
6
4
2
103
6
4
2
2
103
6 8
2
4
104
Prospective Current In Amps RMS
High speed
fuses
104
105
105
2
FWA-4000AH
FWA-3000AH
104
FWA-2500AH
FWA-2000AH
FWA-1500AH
FWA-1200AH
FWA-1000AH
103
103
104
105
1007July 2015
Eaton.com/bussmannseries
6-7
North American
Arc voltage
Specifications
Description: North American style
stud-mount fuses.
Dimensions: See dimensions
illustrations.
Ratings:
Volts: 150Vac/dc*
Amps: 70-1000A
IR: 100kA Sym. (70-400A)
200kA Sym. (450-1000A)
20kA @150Vdc (70-800A)
100kA @ 80Vdc (70-1000A)
*1000A rated @ 80Vdc.
Agency information: CE, UL Recognized JFHR2.E91958
Electrical characteristics
Total clearing I2t
Dimensions - in
Fig. 1: 70-400A
1.5
1.0
0.3
0.2
0.15
22
1)
70
102
1.936
1.156
Eg
150
0.125
1.000
Fig. 2: 500-1000A
0.438
3.500
2.438
1.250
1.000
Catalog
number
FWA-70B
FWA-80B
FWA-100B
FWA-125B
FWA-150B
FWA-200B
FWA-250B
FWA-300B
FWA-350B
FWA-400B
FWA-500A
FWA-600A
FWA-700A
FWA-800A
FWA-1000A
1) 500-1000A Range
2) 70-400A Range
2.656
2.188
0.750 0.312
2)
0.250
1.500
Rated
current
RMS-amps
70
80
100
125
150
200
250
300
350
400
500
600
700
800
1000
Typical applications
DC common bus
DC drives
Power converters/rectifiers
Reduced voltage starters
1.0
Kp
0.8
50
100
Eaton.com/bussmannseries
Eg
150
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
70
Ib
80 90 100%
Watts
loss
6.9
7.7
9.0
11.2
13.5
17.6
22.5
27.0
30.6
35.2
35.0
47.0
49.0
58.0
60.0
0.406
100
Electrical characteristics
I2t (A2 Sec)
Clearing
Pre-arc
at 150V
470
4000
670
6000
1200
12000
1870
18000
2700
26000
4780
45000
7470
70000
10760
100000
15700
140000
20300
180000
39000
120000
46000
140000
75000
220000
92000
280000
170000
510000
6-8
200
Power losses
0.5
300
UL
FWA-500A
FWA-600A
FWA-700A
FWA-800A
FWA-1000A
2
102
6
4
2
101
6
4
2
100
6
4
2
101
6
4
FWA-70A
FWA-80A
FWA-100A
FWA-125A
FWA-150A
2
102
6
4
2
103
6
4
FWA-200A
FWA-250A
FWA-300A
FWA-350A
FWA-400A
2
4
10
102
6 8
2
4
6
103
Prospective Current In Amps RMS
104
High speed
fuses
6
4
FWA-400A
FWA-350A
2
FWA-300A
FWA-250A
104
FWA-200A
FWA-150A
6
FWA-100A
10
FWA-80A
FWA-70A
102
2
102
2
103
2
104
6
105
1007July 2015
Eaton.com/bussmannseries
6-9
North American
Arc voltage
Specifications
Description: North American style
stud-mount and flush-end fuses.
Dimensions: See dimensions
illustrations.
Ratings:
Volts: 250Vac/dc
Amps: 35-2500A
IR: 200kA RMS Sym.
50kA@250Vdc (35-800A)
Agency information: CE, UL Recognized JFHR2.E56412
and CSA Component Acceptance file Class 1422-30, (53787)
on 35-800A fuses (50kA IR @250Vdc).
Electrical characteristics
Total clearing I2t
1.5
1.0
1)
0.5
Catalog numbers
0.15
Fig. 1:
35-800A
D
2.59
2.44
2.94
3.03
1.50
75
125
200
250
E
2.25
2.19
2.25
2.28
F
0.34
0.34
0.41
0.41
G
0.63
1.00
1.00
1.50
H
0.13
0.19
0.25
0.25
J
0.52
0.47
0.75
0.78
300
Tapped
thread
depth
3
8-24 x 12
3
8--24 x 12
Fig. 3:
1500-2500A
A
A D E C
Rated
current
RMS-amps
35
40
45
50
60
70
80
90
100
125
150
175
200
225
250
275
300
350
400
450
500
600
700
800
1000
1200
1500
1600
2000
2500
G
H
1007July 2015
Eaton.com/bussmannseries
800
600
500
400
1)
300
200
50
1.0
Kp
0.8
100
2)
150
200
Eg
1) 35-800A Range
2) 1000-2500A Range
250
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
70
Ib
80 90 100%
Watts
loss
4.2
5.2
5.7
6.0
8.1
7.2
8.1
9.0
10.0
12.5
15.7
18.5
22
24
27
31
32
39
44
49
54
62
72
84
100
103
140
140
151
163
UL
103
Electrical characteristics
I2t (A2 Sec)
Clearing
Pre-arc
at 250V
50
230
60
310
80
390
100
520
140
740
330
1400
430
1850
570
2450
740
3150
1130
4850
1620
6950
2170
9300
2790
12000
3210
14700
3960
18100
4720
21600
6000
27300
10600
48600
14500
66100
22100
101000
28000
128000
41100
188000
48800
190000
59000
230000
44000
360000
92000
750000
120000
880000
160000
1200000
320000
2300000
670000
4700000
Eg
1) 35-800A Range
2) 1000-2500A Range
Fig. 2:
1000-1200A
Catalog
number
FWX-35A
FWX-40A
FWX-45A
FWX-50A
FWX-60A
FWX-70A
FWX-80A
FWX-90A
FWX-100A
FWX-125A
FWX-150A
FWX-175A
FWX-200A
FWX-225A
FWX-250A
FWX-275A
FWX-300A
FWX-350A
FWX-400A
FWX-450A
FWX-500A
FWX-600A
FWX-700A
FWX-800A
FWX-1000AH
FWX-1200AH
FWX-1500AH
FWX-1600AH
FWX-2000AH
FWX-2500AH
2)
0.3
0.2
Dimensions - in
Amp
range
Fig. A
B
C
35-60
1
3.19 0.81 1.59
70-200
1
3.13 1.22 1.59
225-600
1
3.84 1.50 1.59
700-800
1
3.84 2.00 1.59
1000-1200
2
2.59 3.00 1.50
1500-2500
3
2.59 3.50 1.50
1mm = 0.0394 / 1 = 25.4mm
Power losses
Watts loss at rated current is
given in the electrical char
acteristics. The curve allows
the calculation of the power
losses at load currents lower
than the rated current. The
correction factor, K p , is
given as a function of the
RMS load current, Ib , in %
of the rated current .
1.4
1.2
Typical applications
DC common bus
DC drives
Power converters/rectifiers
Reduced voltage starters
North American
Time-current curve
Time-current curve
104
6
4
104
103
FWX-200A
FWX-350A
FXW-400A
FWX-500A
FWX-600A
FWX-800A
102
FWX-1000AH
FWX-1200AH
FWX-1500AH
FWX-1600AH
FWX-2000AH
FWX-2500AH
10
101
6
4
2
100
103
6
4
FWX-35A
FWX-40A
FWX-60A
FWX-70A
FWX-100A
FWX-150A
101
102
103
104
102
103
Prospective Current In Amps RMS
104
101
6
4
2
0
10
6
4
2
101
6
4
2
102
6
4
105
103
6
4
FWX-800A
FWX-600A
FWX-400A
FWX-300A
FWX-200A
103
2
4
6
104
Prospective Current In Amps RMS
105
High speed
fuses
104
2
104
6
FWX-2500AH
FWX-150A
FWX-100A
FWX-70A
FWX-60A
FWX-45A
FWX-35A
102
102
103
104
10
105
FWX-2000AH
FWX-1600AH
FWX-1500AH
FWX-1200AH
FWX-1000AH
104
6
4
103
103
104
105
1007July 2015
Eaton.com/bussmannseries
6-11
North American
Specifications
Description: North American style
stud-mount fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 500Vac/dc (35-800A only)
Amps: 35-1600A
IR: 200kA Sym.
50kA @ 500Vdc (35-800A)
Agency information: CE, UL Recognized JFHR2.E91958
FWH-_B (35-200A, 1000-1200A), JFHR2.E56412
FWH-_A (225-600A), CSA Component Acceptance Class
1422-30, File 53787 (35-1600A).
Electrical characteristics
Total clearing I2t
Dimensions - in
Fig.
1
1
1
1
1
1
1
2
A
B
3.188 0.813
3.625 0.947
3.625 1.156
4.340 1.500
4.340 2.000
6.340 2.500
6.969 3.000
See Drawing
Fig. 1: 35-1200A
C
1.593
1.736
1.836
2.090
2.090
2.090
3.219
1.5
1.0
0.5
0.3
0.2
Catalog numbers
2)
250
400
1) 35-800A Range
2) 1000-1600A Range
E
2.193
2.807
2.768
2.750
2.780
3.440
4.475
F
0.344
0.352
0.344
0.410
0.410
0.530
0.625
G
0.719
0.750
1.000
1.000
1.500
2.000
2.375
Catalog
numbers
FWH-35B
FWH-40B
FWH-45B
FWH-50B
FWH-60B
FWH-70B
FWH-80B
FWH-90B
FWH-100B
FWH-125B
FWH-150B
FWH-175B
FWH-200B
FWH-225A
FWH-250A
FWH-275A
FWH-300A
FWH-325A
FWH-350A
FWH-400A
FWH-450A
FWH-500A
FWH-600A
FWH-700A
FWH-800A
FWH-1000A
FWH-1200A
FWH-1400A
FWH-1600A
Eg
500
H
0.125
0.125
0.188
0.250
0.250
0.380
0.438
J
0.518
0.375
0.406
0.750
0.780
1.300
1.120
G F
0.125
1)
0.15
100
D
2.541
2.853
2.892
3.440
3.530
4.970
5.465
B
J
0.5
10.219
0.625
3.219
3.5
103
800
600
2)
500
400
300
100
1.0
Kp
0.8
1007July 2015
Eaton.com/bussmannseries
1)
200
300
400
Eg
500
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
70
Ib
80 90 100%
Watts
loss
8
7.5
7.5
7.5
9.9
10.6
12.7
15
17
25
30
35
40
39
41
46
51
53
58
65
74
84
108
120
129
145
180
210
230
1.2
Electrical characteristics
I2t (A2 Sec)
Clearing
Pre-arc
at 500V
34
150
76
320
105
450
135
670
210
900
210
900
305
1400
360
1600
475
2000
800
3500
1100
4600
1450
6200
1900
8500
4600
23300
6300
32200
7900
40300
9800
49800
13700
63800
14500
72900
19200
96700
24700
127000
29200
149000
41300
206000
55000
298000
76200
409000
92000
450000
122000
600000
200000
1000000
1400000
290000
1.625
1.750
0.75
4.25
6.219
8.969
Rated
current
RMS-amps
35
40
45
50
60
70
80
90
100
125
150
175
200
225
250
275
300
325
350
400
450
500
600
700
800
1000
1200
1400
1600
UL
1.6
Power losses
A
D
E
C
Fig. 2: 1400-1600A
2.0
Arc voltage
Typical applications
DC common bus
DC drives
Power converters/rectifiers
Reduced voltage starters
North American
104
6
4
2
103
6
4
102
FWH-300A
FWH-400A
FWH-500A
FWH-600A
FWH-800A
2
102
6
4
101
6
4
101
FWH-900A
FWH-1000A
FWH-1200A
FWH-1400A
FWH-1600A
2
100
6
4
FWH-80B
FWH-90B
FWH-100B
FWH-125B
FWH-150B
FWH-175B
FWH-200B
FWH-35B
FWH-40B
FWH-45B
FWH-50B
FWH-60B
FWH-70B
2
101
6
4
2
102
6
4
100
101
102
2
103
6
4
103
2
10
2
4
6 8
2
103
Prospective Current In Amps RMS
102
104
104
102
105
High speed
fuses
103
104
Prospective Current In Amps RMS
105
105
FWH-1600A
FWH-1400A
FWH-1200A
FWH-1000A
104
Peak Let-Through Current
104
6
4
103
FWH-800A
FWH-600A
FWH-500A
FWH-400A
FWH-300A
FWH-250A
103
FWH-200B
6
FWH-150B
FWH-125B
FWH-100B
FWH-80B
FWH-60B
FWH-50B
FWH-40B
FWH-35B
102
102
102
103
104
105
102
103
104
Prospective Short-Circuit Current Symmetrical RMS
105
1007July 2015
Eaton.com/bussmannseries
6-13
North American
KAC-1
KAC-2
KAC-3
KAC-4
KAC-5
KAC-6
KAC-7
KAC-8
KAC-9
KAC-10
KAC-12
KAC-15
KAC-17.5
KAC-20
KAC-25
KAC-30
KAC-35
KAC-40
KAC-45
KAC-50
KAC-60
KAC-70
KAC-80
KAC-90
KAC-100
KAC-110
KAC-125
KAC-150
Specifications
Description: North American style
stud-mount fuses. These 600V fuses are
supplied as replacements only. For new
installations, Eaton recommends the 700V
FWP fuse.
Dimensions: See dimensions illustrations.
Ratings:
Volts: 600Vac
Amps: 1-1000A
IR: 200kA RMS Sym.
Agency information: CE, UL Recognized
JFHR2.E56413 on 1-600A only.
KAC-175
KAC-200
KAC-225
KAC-250
KAC-300
KAC-350
KAC-400
KAC-450
KAC-500
KAC-600
KAC-700
KAC-800
KAC-1000
Dimensions - in
Amp
range
1-30A
35-60A
70-100A
110-200A
225-400A
450-800A
1000A
Fig.
1
2
2
2
2
1
1
A
2.875
4.375
5.000
5.140
6.182
6.250
7.250
B1
2.500
4.750
4.750
B2
3.750
4.063
4.390
4.815
B3
3.500
3.656
3.766
4.565
C
1.875
2.750
2.750
2.906
3.000
3.063
3.063
D
0.406
0.625
0.750
1.000
1.625
2.000
2.750
0.343
0.406
0.406
0.562
F
0.563
0.813
1.000
1.500
2.000
2.500
3.500
G
0.063
0.094
0.125
0.188
0.250
0.250
0.375
H
0.257
0.468
0.609
0.718
0.687
0.563
0.563
B1
C
F
H
Fig. 2: 35-400A
A
B2
B3
C
D
G
F
E
H
1007July 2015
Eaton.com/bussmannseries
Dimensions - in
Fig.
1
2
1
1
1
3
A
B
C
4.375 3.750 3.500
See Drawing
4.406 3.719 3.594
5.125 4.188 3.563
5.125 4.389 3.687
See Drawing
KBC-35
KBC-40
KBC-45
KBC-50
KBC-60
KBC-70
KBC-80
KBC-90
KBC-100
KBC-110
KBC-125
KBC-150
KBC-175
KBC-200
KBC-225
KBC-250
KBC-300
KBC-350
KBC-400
KBC-450
KBC-500
KBC-600
KBC-800
D
E
F
G
H
I
2.750 0.343 0.625 0.813 0.094 0.468
2.906 0.312 0.875 1.219 0.187 0.375
2.906 0.406 1.000 1.500 0.250 0.719
2.875 0.406 1.500 2.000 0.250 0.757
A
B
C
D
High speed
fuses
0.312
0.750
1.000
2.906
3.656
0.125
4.406
Fig. 2: 70-100A
Fig. 3: 800A
2.859
2.500
/" - 24 /"
0.750
3.750
4.000
4.000
0.750
3.750
1007July 2015
Eaton.com/bussmannseries
6-15
North American
Arc voltage
Specifications
Description: North American style
stud-mount fuses.
Dimensions: See dimensions
illustrations.
Ratings:
Volts: 700Vac/dc
Amps: 5-1200A
IR: 200kA RMS Sym.
50kA @700Vdc
Agency information: CE, UL Recognized JFHR2.E91958
FWP-_B (5-100A, 700-1200A), JFHR2.E56412 FWP-_A
(125-600A) and CSA Component Acceptance file Class
1422-30, (53787) on 5-800A
1.5
Electrical characteristics
Total clearing I2t
Dimensions - in
A
B
2.870 0.563
4.375 0.813
4.406 0.947
5.090 1.500
5.090 2.000
7.090 2.500
6.630 2.000
See Drawing
See Drawing
C
1.855
2.750
2.594
2.840
2.840
2.840
2.844
1.0
0.5
0.3
0.2
2)
1)
0.15
316
D
2.477
3.708
3.625
4.190
4.280
5.720
5.562
Power losses
E
2.477
3.312
3.563
3.500
3.530
4.190
5.062
Catalog numbers
Catalog
numbers
FWP-5B
FWP-10B
FWP-15B
FWP-20B
FWP-25B
FWP-30B
FWP-35B
FWP-40B
FWP-50B
FWP-60B
FWP-70B
FWP-80B
FWP-90B
FWP-100B
FWP-125A
FWP-150A
FWP-175A
FWP-200A
FWP-225A
FWP-250A
FWP-300A
FWP-350A
FWP-400A
FWP-450A
FWP-500A
FWP-600A
FWP-700A
FWP-800A
FWP-900A
FWP-1000A
FWP-1200A
3)
460
604
1) 35-100A Range
2) 125-600A Range
3) 700-1200A Range
F
0.250
0.344
0.344
0.410
0.410
0.530
0.625
G
0.405
0.725
0.750
1.000
1.500
2.000
1.500
700
H
0.063
0.125
0.125
0.250
0.250
0.380
0.250
Eg
I
0.250
0.542
0.375
0.750
0.780
1.300
0.875
Fig. 1: 5-800A
Fig. 2: 900-1000A
Fig. 3: 1200A
3.500
1.375
5.966
7.594
A D E C
9.590 6.840
3.844
5.154
0.625
F
3.500
2.750
0.5
3.844
10.844
0.625
1.031
0.125
0.500
1.625
1.750
4.250
0.750
Rated
current
RMS-amps
5
10
15
20
25
30
35
40
50
60
70
80
90
100
125
150
175
200
225
250
300
350
400
450
500
600
700
800
900
1000
1200
UL
1.6
1.4
1.2
103
1)
8
6
5
4
3
300
400
2)
500
1007July 2015
Eaton.com/bussmannseries
Eg
700
1.0
Kp
0.8
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
Electrical characteristics
I2t (A2 Sec)
Clearing
Pre-arc
at 700V
1.6
10
3.6
20
10
75
26
180
44
340
58
450
34
160
76
320
135
600
210
950
305
2000
360
2400
415
2700
540
3500
1800
7300
2900
11700
4200
16700
5500
22000
7700
31300
10500
42500
17600
71200
23700
95600
31000
125000
36400
137000
45200
170000
66700
250000
54000
300000
78000
450000
91500
530000
120000
600000
195000
1100000
600
1) 125-600A range
2) 35-100 & 700-1200A range
70
Ib
80 90 100%
Watts
loss
1.5
4
5.5
6
7
9
12
12
12
15.5
18
21
25
27
28
32
35
43
45
48
58
65
78
94
107
122
125
140
150
170
190
Typical applications
DC common bus
DC drives
Power converters/rectifiers
Reduced voltage starters
North American
Time-current curve
Time-current curve
104
6
4
104
6
4
2
103
103
6
4
6
4
6
4
6
4
2
Virtual Pre-Arcing Time In Seconds
2
101
6
4
2
100
6
4
FWP-5B
FWP-10B
FWP-15B
FWP-20B
FWP-25B
FWP-30B
2
101
6
4
101
6
4
FWP-35B
FWP-40B
FWP-50B
FWP-60B
FWP-70B
FWP-80B
FWP-90B
FWP-100B
2
100
6
4
2
101
6
4
2
2
102
102
6
4
6
4
2
103
103
6
4
6
4
2
104
FWP-700A
FWP-800A
FWP-900A
FWP-1000A
FWP-1200A
102
102
104
2
101
102
103
2
4
6 8
2
103
Prospective Current In Amps RMS
102
104
104
FWP-1200A
FWP-1000A
6
4
High speed
fuses
FWP-800A
FWP-700A
2
FWP-30B
FWP-25B
104
6
4
10
2
FWP-20B
FWP-15B
FWP-10B
FWP- 5B
10
6
4
6
4
10
6
FWP-100B
4
101
101
102
103
104
105
FWP-70B
FWP-60B
FWP-50B
FWP-40B
FWP-35B
2
10
102
2
103
2
104
6
105
1007July 2015
Eaton.com/bussmannseries
6-17
North American
Time-current curve
10
105
102
FWP-150A
FWP-200A
FWP-300A
FWP-400A
FWP-600A
101
Virtual Pre-Arcing Time In Seconds
104
FWP-600A
FWP-400A
FWP-300A
FWP-200A
FWP-150A
103
100
102
102
103
101
102
103
104
102
103
104
105
Prospective
RMS
ProspectiveCurrent
CurrentInInAmperes
Amps RMS
6-18
104
1007July 2015
Eaton.com/bussmannseries
105
North American
Arc voltage
Specifications
Description: North American style
stud-mount fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 1000Vac/800Vdc
Amps: 35-2000A
IR: 25kA (35-200A)
100kA (250-2000A)
50kA @ 800Vdc
(35-200A, 450-600A)
Agency information: CE, UL
Recognized JFHR8.E91958 on
35-600A only.
B
0.940
1.125
1.526
2.000
2.500
3.500
Fig. 1: 35-2000A
C
3.110
3.085
3.261
3.500
3.465
3.312
1.0
Catalog numbers
0.5
0.3
0.2
0.15
200
D
4.235
4.266
4.803
4.811
5.984
5.472
1200
500
E
4.180
4.156
4.055
4.150
4.706
4.962
F
0.352
0.352
0.445
0.433
0.562
0.625
800
G
0.750
1.000
1.000
1.500
2.000
2.750
A
D
E
C
H
0.125
0.188
0.250
0.250
0.375
0.500
Eg
1000
I
0.380
0.407
0.819
0.764
1.201
0.880
G F
B
J
Catalog
numbers
FWJ-35A
FWJ-40A
FWJ-50A
FWJ-60A
FWJ-70A
FWJ-80A
FWJ-90A
FWJ-100A
FWJ-125A
FWJ-150A
FWJ-175A
FWJ-200A
FWJ-250A
FWJ-300A
FWJ-350A
FWJ-400A
FWJ-500A
FWJ-600A
FWJ-800A
FWJ-1000A
FWJ-1200A
FWJ-1400A
FWJ-1600A
FWJ-1800A
FWJ-2000A
Rated
current
RMS-amps
35
40
50
60
70
80
90
100
125
150
175
200
250
300
350
400
500
600
800
1000
1200
1400
1600
1800
2000
UL
800
400
Kp
200
30 40 50
600
60
Eg
Electrical characteristics
I2t (A2 Sec)
Clearing
Pre-arc
at 1000V
210
2000
300
2500
470
3500
670
5000
1100
6900
1550
9700
1900
12000
2800
17500
4800
35000
6300
45000
7500
65000
11700
80000
16000
112000
23500
164000
231000
33000
47000
330000
39500
329000
61000
520000
87000
500000
190000
1100000
370000
2100000
470000
2700000
700000
4000000
925000
5300000
1330000
7600000
70
Ib
80 90 100%
Watts
loss
7
8
10
11
12
13
14
15
16
25
30
32
50
56
62
67
95
105
182
206
240
248
267
239
244
High speed
fuses
Amp
range
Fig. A
35-60
1 5.000
70-100 1 4.932
125-200 1 5.685
250-400 1 5.768
500-600 1 7.201
800-2000 1 6.811
1.5
1600
Power losses
Electrical characteristics
Total clearing I2t
2000
1007July 2015
Eaton.com/bussmannseries
6-19
North American
Time-current curve
10
Time-current Curve
104
6
4
2
103
103
6
4
102
2
101
6
4
FWJ-200A
FWJ-250A
FWJ-300A
FWJ-350A
FWJ-400A
FWJ-500A
FWJ-600A
6
4
2
100
6
4
101
6
4
2
103
FWJ-800A
FWJ-1000A
FWJ-1200A
FWJ-1400A
FWJ-1600A
FWJ-1800A
FWJ-2000A
6
4
2
100
6
4
2
101
102
6
4
2
101
6
4
2
2
102
6
4
6
4
6
4
2
FWJ-40A
FWJ-50A
FWJ-60A
FWJ-70A
FWJ-80A
FWJ-90A
FWJ-100A
FWJ-125A
FWJ-150A
FWJ-175A
102
6
4
2
103
6
4
6
4
2
104
2
104
102
103
103
104
10
6
4
104
6
4
10
6
4
102
102
103
104
105
104
Prospective
Current
In Amperes
Prospective
Current
in AmpsRMS
1007July 2015
Eaton.com/bussmannseries
105
BS style
Stud type
Connector type
High speed
fuses
C5268
1007July 2015
Eaton.com/bussmannseries
6-21
Introduction
General information
Page
Application information
6-23
Volts
(IEC/UL)
690/700
Size
000,00
1*, 1, 2, 3
1*, 2, 3
4
23, 24
00, 1, 2, 3
00
1000
1250/1300
1000-2000
DCFuses
1*, 1, 2, 3
4
24
1*, 1, 2, 3
4
23
5
Class
aR
aR/gR
aR
aR
aR
aR
aR
aR
aR
aR
gR
aR
aR
aR
aR
aR
aR
aR
aR
aR
aR
aR
aR
aR
aR
Fuse style
DIN 43 653
DIN 43 620
DIN 43 653
Flush End Contact
US Style
French Style
Fuse Curves
DIN 43 620
Flush End Contact
Flush End Contact
DIN 43 620
DIN 43 653
DIN 43 653
Flush End Contact
US Style
Fuse Curves
Flush End Contact
Flush End Contact
DIN 43 653
Flush End Contact
US Style
Fuse Curves
Flush End Contact
Flush End Contact
Flush End Contact
Accessories
Indicator system
Fuse bases
Page
6-25
6-28
6-30
6-32
6-34
6-36
6-38
6-40
6-43
6-45
6-48
6-52
6-54
6-56
6-58
6-60
6-62
6-65
6-67
6-69
6-71
6-73
6-75
6-78
6-80
6-81
Page
6-92
6-93
Volts
690
1250
AC
X
X
6-22
Square body style fuses are a very attractive solution for high
power applications which require a compact design with
superior performance. The construction and design of square
body style fuses make it easy for Eaton to manufacture
custom products. Our cataloged offering provides only a
sample of the wide variety of product which is available.
Voltage rating
DC
1007July 2015
Eaton.com/bussmannseries
1.2
1
0.8
0.6
40
20
20
40
60
80
High speed
fuses
1007July 2015
Eaton.com/bussmannseries
6-23
170M3669 (400A)
103
Application parameters
Amps
60 Seconds
Once per hour
10 Seconds
2-3 times per week
20 Seconds (max.) Once per month
0.5 Seconds
Less than once per month
300A
500A
700A
1100A
Voltage data
(5) voltage applied to fuse during fault conditions
(+10%)
400V
Temperature data
(6) Temperature inside cubicle in which fuse is located (natural convection cooling only)
60C
102
101
Profile Line
(2) Overload
(3a)
(3b)Overload
(4) Impulse
Frequency of occurrence
Time In Seconds
100
Thyrister data
(7) Thyrister peak voltage withstand
1000V
(8) Thyrister I2t withstand at 10 milliseconds*
90,000A2s
*Note: The I2t withstand of the thyrister may be given for other impulse durations (i.e., 1.5 ms,
3.5 ms, or 8.3 ms); however, the stated fuse I2t is valid for all impulse durations of 10 ms or
less.
Application procedure
Step
Procedure
Remarks
(Item 2)
OK
(Item 3a)
OK
OK
OK
(Item 3b)
(Item 4)
101
102
102
Special fuses
Other high speed fuses are available from Eaton with voltage
ratings of 380 to 10,000V and current ratings up to 10,000A
in a single unit configuration. Fuses can be supplied with
open fuse, pin indicators. Various types of microswitches
are also available (see page 6-92).
The tentatively selected fuse 170M3669 with microswitch 170H0069 meets all application parameters; no further
selection would be necessary.
6-24
103
Current In Amperes
1007July 2015
Eaton.com/bussmannseries
Specifications
Description: Square body DIN
43-653 stud mount high speed
fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 690Vac (IEC)
700Vac (UL)
Amps: 10-400A
IR: 200kA RMS Sym.
Agency information: CE,
Designed and tested to IEC
60269: Part 4. UL Recognized
E125085.JFHR2, CSACertified:
Class 53787, File 1422-30 on
Size 000.
Electrical
characteristics
1.5
Total clearing I t
2
Size
000
00
D
40
51
E
21
30
F
20
28
0.5
0.4
0.3
0.2
Eg
G
51
67
H
8
10
54
K
2
2
Indicator
300
400
500
Eg
600 690
1.0
Kp
0.8
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
70
Ib
80 90 100%
Dimensions (mm)
Type 00B/60, 00BTN/60
30
62
64
54 Max
78
200
Typical applications
DC Common bus
DC Drives
Power converters/rectifiers
100
Power losses
UL
High speed
fuses
Dimensions - mm
Type -U/80, -/80, -TN/80
1.0
1.4
1.2
103
9
8
7
6
Arc voltage
48
Indicator
1007July 2015
Eaton.com/bussmannseries
6-25
Catalog numbers
-TN/80
-/80
Type T
Visual
indicator
indicator
for micro
170M1358
170M1408
170M1359
170M1409
170M1360
170M1410
170M1361
170M1411
170M1362
170M1412
170M1363
170M1413
170M1364
170M1414
170M1365
170M1415
170M1366
170M1416
170M1367
170M1417
170M1368
170M1418
170M1369
170M1419
170M1370
170M1420
170M1371
170M1421
170M1372
170M1422
170M2608
170M2658
170M2609
170M2659
170M2610
170M2660
170M2611
170M2661
170M2612
170M2662
170M2613
170M2663
170M2614
170M2664
170M2615
170M2665
170M2616
170M2666
170M2617
170M2667
170M2618
170M2668
170M2619
170M2669
170M2620
170M2670
170M2621
170M2671
Catalog numbers
-U/80
Without
indicator
170M1308
170M1309
170M1310
170M1311
170M1312
170M1313
170M1314
170M1315
170M1316
170M1317
170M1318
170M1319
170M1320
170M1321
170M1322
6-26
00B/60
Visual
indicator
00BTN/60
Type T
indicator
for micro
Electrical characteristics
Size
000
170M2708
170M2709
170M2710
170M2711
170M2712
170M2713
170M2714
170M2715
170M2716
170M2717
170M2718
170M2719
170M2720
170M2721
170M2758
170M2759
170M2760
170M2761
170M2762
170M2763
170M2764
170M2765
170M2766
170M2767
170M2768
170M2769
170M2770
170M2771
00
Rated
current
RMS-amps
10
16
20
25
32
40
50
63
80
100
125
160
200
250
315
25
32
40
50
63
80
100
125
160
200
250
315
350
400
1007July 2015
Eaton.com/bussmannseries
Watts
loss
3.0
5.5
7
9
10
12
15
16
19
24
28
32
37
42
52
6
7
9
10
12
15
20
25
30
35
45
55
60
70
25A
32A
40A
50A
63A
80A
100A
125A
160A
200A
250A
315A
350A
400A
32A
40A
50A
63A
104
80A
100A
125A
160A
200A
250A
315A
Time-current curve
16A
20A
25A
Time-current curve
10A
104
103
103
102
102
10
A
A
100
101
102
100
101
102
103
1x104
101
103
1x101
102
103
Prospective Current In Amps RMS
104
102
103
Prospective Current in Amps RMS
104
103
250A
200A
160A
125A
100A
80A
63A
50A
40A
32A
25A
20A
16A
10A
104
103
102
102
2x101
1x101
A
1x101
A
102
103
104
Prospective Short-Circuit Current Symmetrical RMS
105
2x10
1x101
102
103
104
105
1007July 2015
Eaton.com/bussmannseries
6-27
High speed
fuses
104
1x104
Arc voltage
Specifications
Description: Square body DIN 43
620 blade style high speed fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 690Vac
Amps: 10-315A
IR: 200kA RMS Sym.
Agency information: CE, Designed and tested to IEC
60269: Part 4. UL Recognized E125085.JFHR2. and CSA
Component Acceptance file Class 1422-30, (53787)
Power losses
Electrical
characteristics
Total clearing I2t
Dimensions - mm
DIN 000 Type T
54 Max
Indicator
15
48
79
21
35
6-28
1007July 2015
Eaton.com/bussmannseries
Catalog numbers
DIN
Type T
indicator
for micro
170M1558D*
170M1559D*
170M1560D*
170M1561D*
170M1562D*
170M1563D*
170M1564D*
170M1565D*
170M1566D
170M1567D
170M1568D
170M1569D
170M1570D
170M1571D
170M1572D
Catalog numbers
Size
000
00
Electrical characteristics
Rated
current
RMS-amps
10
16
20
25
32
40
50
63
80
100
125
160
200
250
315
Rated current
The rated current of this fuse range has been given with
copper conductors that have a current density of 1.3A/mm2
(IEC 60269-4). For conductor cross section according to IEC
60269-1, the fuses with a rated current higher than 125A
must be derated. Please contact Eaton for application
assistance.
High speed
fuses
1007July 2015
Eaton.com/bussmannseries
6-29
Specifications
Description: Square body DIN 43
653 stud-mount high speed fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 690Vac (IEC)
700Vac (UL)
Amps: 40-2000A
IR: 200kA RMS Sym.
Agency information: CE,
Designed and tested to IEC
60269: Part 4. UL Recognized
E125085.JFHR2, CSACertified:
Class 53787, File 1422-30.
A
50
50
50
51
B
104
108
108
109
Dimensions - mm
B**
134
138
138
139
1.5
1.0
2) 1)
0.5
0.4
0.3
0.2
Eg
C
78
78
78
78
C**
108
108
108
108
D***
58
66
75
90
E
45
53
61
76
H
22
25
25
30
UL
5
4
3
200
1.0
Kp
0.8
Power losses
Electrical
characteristics
Total clearing I2t
1.4
1.2
103
9
8
7
6
Arc voltage
300
400
Eg
500
600 690
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
70
Ib
80 90 100%
C
A
11
E
6-30
1007July 2015
11
B
Eaton.com/bussmannseries
Catalog numbers
-TN/80
Type T
indicator
for micro
170M3058
170M3059
170M3060
170M3061
170M3062
170M3063
170M3064
170M3065
170M3066
170M3067
170M3068
170M3069
170M3070
170M3071
170M3072
170M3073
170M4058
170M4059
170M4060
170M4061
170M4062
170M4063
170M4064
170M4065
170M4066
170M4067
170M4068
170M4069
170M5058
170M5059
170M5060
170M5061
170M5062
170M5063
170M5064
170M5065
170M5066
170M5067
170M5068
170M6058
170M6059
170M6060
170M6061
170M6062
170M6063
170M6064
170M6065
170M6066
170M6067
170M6068
170M6069
170M6070
170M6071
Catalog numbers
-KN/80
Type K
-/110
indicator
visual
for micro
for micro
170M3108
170M3158
170M3109
170M3159
170M3110
170M3160
170M3111
170M3161
170M3112
170M3162
170M3113
170M3163
170M3114
170M3164
170M3115
170M3165
170M3116
170M3166
170M3117
170M3167
170M3118
170M3168
170M3119
170M3169
170M3120
170M3170
170M3121
170M3171
170M3122
170M3172
170M3123
170M3173
170M4108
170M4158
170M4109
170M4159
170M4110
170M4160
170M4111
170M4161
170M4112
170M4162
170M4113
170M4163
170M4114
170M4164
170M4115
170M4165
170M4116
170M4166
170M4117
170M4167
170M4118
170M4168
170M4119
170M4169
170M5108
170M5158
170M5109
170M5159
170M5110
170M5160
170M5111
170M5161
170M5112
170M5162
170M5113
170M5163
170M5114
170M5164
170M5115
170M5165
170M5116
170M5166
170M5117
170M5167
170M5118
170M5168
170M6108
170M6158
170M6109
170M6159
170M6110
170M6160
170M6111
170M6161
170M6112
170M6162
170M6113
170M6163
170M6114
170M6164
170M6165
170M6115
170M6116
170M6166
170M6117
170M6167
170M6118
170M6168
170M6119
170M6169
170M6120
170M6170
170M6121
170M6171
-TN/110
Type T
indicator
for micro
170M3208
170M3209
170M3210
170M3211
170M3212
170M3213
170M3214
170M3215
170M3216
170M3217
170M3218
170M3219
170M3220
170M3221
170M3222
170M3223
170M4208
170M4209
170M4210
170M4211
170M4212
170M4213
170M4214
170M4215
170M4216
170M4217
170M4218
170M4219
170M5208
170M5209
170M5210
170M5211
170M5212
170M5213
170M5214
170M5215
170M5216
170M5217
170M5218
170M6208
170M6209
170M6210
170M6211
170M6212
170M6213
170M6214
170M6215
170M6216
170M6217
170M6218
170M6219
170M6220
170M6221
-KN/110
Type K
indicator
-KN/80
170M3258
170M3259
170M3260
170M3261
170M3262
170M3263
170M3264
170M3265
170M3266
170M3267
170M3268
170M3269
170M3270
170M3271
170M3272
170M3273
170M4258
170M4259
170M4260
170M4261
170M4262
170M4263
170M4264
170M4265
170M4266
170M4267
170M4268
170M4269
170M5258
170M5259
170M5260
170M5261
170M5262
170M5263
170M5264
170M5265
170M5266
170M5267
170M5268
170M6258
170M6259
170M6260
170M6261
170M6262
170M6263
170M6264
170M6265
170M6266
170M6267
170M6268
170M6269
170M6270
170M6271
Size
1*
Rated
RMS-amps
40
50
63
80
100
125
160
200
250
315
350
400
450
500
550
630
200
250
315
350
400
450
500
550
630
700
800
900
400
450
500
550
630
700
800
900
1000
1100
1250
500
550
630
700
800
900
1000
1100
1250
1400
1500
1600
1800
2000
1007July 2015
Electrical characteristics
Eaton.com/bussmannseries
Clearing
loss
9
11
14
18
21
26
30
35
40
50
55
60
65
70
75
80
45
55
58
60
65
70
72
75
80
85
95
100
65
70
75
80
90
95
105
110
115
120
130
95
100
105
110
115
120
125
130
140
155
160
160
165
175
High speed
fuses
-/80
visual
watts
indicator
170M3008
170M3009
170M3010
170M3011
170M3012
170M3013
170M3014
170M3015
170M3016
170M3017
170M3018
170M3019
170M3020
170M3021
170M3022
170M3023
170M4008
170M4009
170M4010
170M4011
170M4012
170M4013
170M4014
170M4015
170M4016
170M4017
170M4018
170M4019
170M5008
170M5009
170M5010
170M5011
170M5012
170M5013
170M5014
170M5015
170M5016
170M5017
170M5018
170M6008
170M6009
170M6010
170M6011
170M6012
170M6013
170M6014
170M6015
170M6016
170M6017
170M6018
170M6019
170M6020
170M6021
6-31
Specifications
Description: Square body flush
end contact high speed fuses.
Dimensions: See dimensions
illustrations.
Ratings:
Volts: 690Vac (IEC)
700Vac (UL)
Amps: 40-2000A
IR: 200kA RMS Sym.
Agency information: CE, Designed and tested to IEC
60269: Part 4. UL Recognized E125085.JFHR2, CSA
Certified: Class 53787, File 1422-30.
Electrical
characteristics
Total clearing I2t
1.5
1.0
1.4
1.2
103
9
8
7
6
Arc voltage
Power losses
2) 1)
0.5
0.4
0.3
0.2
Eg
UL
5
4
3
200
1.0
Kp
0.8
300
400
500
Eg
600 690
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
70
Ib
80 90 100%
Dimensions - mm
Type -B/-, -BKN/-, -G/-, -GKN/-
Size
1*
1
2
3
A
50
50
50
51
B
51
51
51
53
D
59
69
77
92
E
45
53
61
76
F
M8
M8
M10
M12
F** (in)
5
16 - 18 UNC-2B
5
16 - 18 UNC-2B
3
8 - 16 UNC-2B
1
2 - 13 UNC-2B
G
5
8
10
10
H
17
20
24
30
6-32
1007July 2015
Eaton.com/bussmannseries
Catalog numbers
-GKN/Type K
indicator
for micro
170M3558
170M3559
170M3560
170M3561
170M3562
170M3563
170M3564
170M3565
170M3566
170M3567
170M3568
170M3569
170M3570
170M3571
170M3572
170M3573
170M4558
170M4559
170M4560
170M4561
170M4562
170M4563
170M4564
170M4565
170M4566
170M4567
170M4568
170M4569
170M5558
170M5559
170M5560
170M5561
170M5562
170M5563
170M5564
170M5565
170M5566
170M5567
170M5568
170M6558
170M6559
170M6560
170M6561
170M6562
170M6563
170M6564
170M6565
170M6566
170M6567
170M6568
170M6569
170M6570
170M6571
Electrical characteristics
Size
1*
Rated
current
RMS-amps
40
50
63
80
100
125
160
200
250
315
350
400
450
500
550
630
200
250
315
350
400
450
500
550
630
700
800
900
400
450
500
550
630
700
800
900
1000
1100
1250
500
550
630
700
800
900
1000
1100
1250
1400
1500
1600
1800
2000
Watts
loss
9
11
14
18
21
26
30
35
40
50
55
60
65
70
75
80
45
55
58
60
65
70
72
75
80
85
95
100
65
70
75
80
90
95
105
110
115
120
130
95
100
105
110
115
120
125
130
140
155
160
160
165
175
1007July 2015
High speed
fuses
-B/Visual
indicator
170M3408
170M3409
170M3410
170M3411
170M3412
170M3413
170M3414
170M3415
170M3416
170M3417
170M3418
170M3419
170M3420
170M3421
170M3422
170M3423
170M4408
170M4409
170M4410
170M4411
170M4412
170M4413
170M4414
170M4415
170M4416
170M4417
170M4418
170M4419
170M5408
170M5409
170M5410
170M5411
170M5412
170M5413
170M5414
170M5415
170M5416
170M5417
170M5418
170M6408
170M6409
170M6410
170M6411
170M6412
170M6413
170M6414
170M6415
170M6416
170M6417
170M6418
170M6419
170M6420
170M6421
Catalog numbers
-BKN/Type K
-G/indicator
visual
for micro
indicator
170M3458
170M3508
170M3459
170M3509
170M3460
170M3510
170M3461
170M3511
170M3462
170M3512
170M3463
170M3513
170M3464
170M3514
170M3465
170M3515
170M3466
170M3516
170M3467
170M3517
170M3468
170M3518
170M3469
170M3519
170M3470
170M3520
170M3471
170M3521
170M3472
170M3522
170M3473
170M3523
170M4458
170M4508
170M4459
170M4509
170M4460
170M4510
170M4461
170M4511
170M4462
170M4512
170M4463
170M4513
170M4464
170M4514
170M4465
170M4515
170M4466
170M4516
170M4467
170M4517
170M4468
170M4518
170M4469
170M4519
170M5458
170M5508
170M5459
170M5509
170M5510
170M5460
170M5461
170M5511
170M5462
170M5512
170M5463
170M5513
170M5464
170M5514
170M5465
170M5515
170M5466
170M5516
170M5467
170M5517
170M5518
170M5468
170M6458
170M6508
170M6459
170M6509
170M6460
170M6510
170M6461
170M6511
170M6462
170M6512
170M6463
170M6513
170M6464
170M6514
170M6465
170M6515
170M6466
170M6516
170M6467
170M6517
170M6468
170M6518
170M6469
170M6519
170M6470
170M6520
170M6471
170M6521
Eaton.com/bussmannseries
6-33
Arc voltage
Specifications
Description: Square body US
style high speed fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 690Vac (IEC)
700Vac (UL)
Amps: 40-200A
IR: 200kA RMS Sym.
Agency information: CE, Designed and tested to IEC
60269: Part 4. UL Recognized E125085.JFHR2, CSA
Certified: Class 53787, File 1422-30.
Electrical
characteristics
Total clearing I2t
1.5
1.0
2) 1)
0.5
0.4
0.3
0.2
A
50
50
50
51
B
110
136
135
135
B**
148
157
159
155
C1
85
104
105
106
C1**
123
126
125
125
Dimensions - mm
Type -FU/-, -FKE/-, FU/115-, -FKE/115
Size
1*
1
2
3
Power losses
C2
72
78
78
77
C2**
110
100
99
97
D
59
69
77
92
E
45
53
61
76
H
20
25
25
36
I
10
14
14
16
6-34
C1
200
300
1.0
Kp
0.8
400
Eg
500
600 690
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
70
1007July 2015
Eaton.com/bussmannseries
Ib
80 90 100%
C2
Typical applications
DC common bus
DC drives
Power converters/rectifiers
Reduced voltage starters
A
E
UL
1.4
1.2
103
9
8
7
6
Catalog numbers
-FKE/115
Type K
indicator
for micro
170M3758
170M3759
170M3760
170M3761
170M3762
170M3763
170M3764
170M3765
170M3766
170M3767
170M3768
170M3769
170M3770
170M3771
170M3772
170M3773
170M4758
170M4759
170M4760
170M4761
170M4762
170M4763
170M4764
170M4765
170M4766
170M4767
170M4768
170M4769
170M5758
170M5759
170M5760
170M5761
170M5762
170M5763
170M5764
170M5765
170M5766
170M5767
170M5768
170M6758
170M6759
170M6760
170M6761
170M6762
170M6763
170M6764
170M6765
170M6766
170M6767
170M6768
170M6769
170M6770
170M6771
Electrical characteristics
Size
1*
Rated
current
RMS-amps
40
50
63
80
100
125
160
200
250
315
350
400
450
500
550
630
200
250
315
350
400
450
500
550
630
700
800
900
400
450
500
550
630
700
800
900
1000
1100
1250
500
550
630
700
800
900
1000
1100
1250
1400
1500
1600
1800
2000
Watts
loss
9
11
14
18
21
26
30
35
40
50
55
60
65
70
75
80
45
55
58
60
65
70
72
75
80
85
95
100
65
70
75
80
90
95
105
110
115
120
130
95
100
105
110
115
120
125
130
140
155
160
160
165
175
1007July 2015
High speed
fuses
-FU/without
indicator
170M3608
170M3609
170M3610
170M3611
170M3612
170M3613
170M3614
170M3615
170M3616
170M3617
170M3618
170M3619
170M3620
170M3621
170M3622
170M3623
170M4608
170M4609
170M4610
170M4611
170M4612
170M4613
170M4614
170M4615
170M4616
170M4617
170M4618
170M4619
170M5608
170M5609
170M5610
170M5611
170M5612
170M5613
170M5614
170M5615
170M5616
170M5617
170M5618
170M6608
170M6609
170M6610
170M6611
170M6612
170M6613
170M6614
170M6615
170M6616
170M6617
170M6618
170M6619
170M6620
170M6621
Catalog numbers
-FKE/Type K
-FU/115
indicator
without
for micro
indicator
170M3658
170M3708
170M3659
170M3709
170M3660
170M3710
170M3661
170M3711
170M3662
170M3712
170M3663
170M3713
170M3664
170M3714
170M3665
170M3715
170M3666
170M3716
170M3667
170M3717
170M3668
170M3718
170M3669
170M3719
170M3670
170M3720
170M3721
170M3671
170M3672
170M3722
170M3673
170M3723
170M4658
170M4708
170M4659
170M4709
170M4660
170M4710
170M4661
170M4711
170M4662
170M4712
170M4663
170M4713
170M4664
170M4714
170M4665
170M4715
170M4666
170M4716
170M4667
170M4717
170M4668
170M4718
170M4669
170M4719
170M5658
170M5708
170M5659
170M5709
170M5660
170M5710
170M5661
170M5711
170M5662
170M5712
170M5663
170M5713
170M5664
170M5714
170M5665
170M5715
170M5666
170M5716
170M5667
170M5717
170M5668
170M5718
170M6658
170M6708
170M6659
170M6709
170M6660
170M6710
170M6661
170M6711
170M6662
170M6712
170M6663
170M6713
170M6664
170M6714
170M6715
170M6665
170M6666
170M6716
170M6667
170M6717
170M6668
170M6718
170M6669
170M6719
170M6670
170M6720
170M6671
170M6721
Eaton.com/bussmannseries
6-35
Arc voltage
Specifications
Description: Square body French
style high speed fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 690Vac (IEC)
700Vac (UL)
Amps: 40-1500A
IR: 200kA RMS Sym.
Agency information: CE, Designed and tested to IEC
60269: Part 4. UL Recognized E125085.JFHR2 and CSA
Component Acceptance file Class 1422-30, (53787) on Sizes
(1, 2, 3) only
1.5
Electrical
characteristics
Total clearing I2t
Dimensions - mm
Type -E/-, -EKN/-
Size
1*
1
2
3
A
50
50
50
51
B
102
111
126
126
C
76
86
91
91
D
59
69
77
92
E
45
53
61
76
1.0
Power losses
0.5
0.4
0.3
0.2
Eg
H
18
25
30
36
I
9
11
13
13
1.4
1.2
103
9
8
7
6
UL
5
4
3
200
1.0
Kp
0.8
300
400
500
Eg
600 690
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
70
Ib
80 90 100%
J
13
11
12
13
H
I
J
6-36
1007July 2015
Eaton.com/bussmannseries
Catalog numbers
Electrical characteristics
Rated
I2t (A2 sec)
current
Clearing Watts
Size RMS-amps
Pre-arc
at 660V
loss
40
40
270
9
50
77
515
11
63
115
770
14
80
185
1250
18
100
360
2450
21
125
550
3700
26
160
1100
7500
30
1*
200
2200
15000
35
28500
40
250
4200
315
7000
46500
50
350
10000
68500
55
A
400 A
15000
105000
60
450
21000
140000
65
500
27000
180000
70
200
1650
11500
45
250
3100
21000
55
315
6200
42000
58
350
8500
59000
60
400
13500
91500
65
1
450
17000
120000
70
500
25000
170000
72
34000
230000
75
550
630
52000
350000
80
700
69500
465000
85
800
105000
725000
95
400
11000
74000
65
450
15500
105000
70
500
21500
145000
75
550
28000
190000
80
2
630
41000
275000
90
700
60500
405000
95
800
86000
575000 105
900
125000
840000
110
4
103
10
1000
180000
1250000105 115
Prospective Current
In Amperes RMS
500
14000
95000
95
550
19500
135000 100
630
31000
210000 105
700
44500
300000
110
800
69500
465000
115
3
900
100000
670000 120
1000
140000
945000 125
1100
190000
1300000 130
1250
290000
1950000 140
1400
370000
2450000 155
1500
460000
3100000 160
400A
450A
500A
550A
630A
700A
800A
900A
1000A 1100A
1250A
Catalog numbers
-E/
-EKN/Type T
Type K
indicator
indicator
for micro
for micro
170M3308
170M3358
170M3309
170M3359
104
170M3310
170M3360
170M3311
170M3361
170M3312
170M3362
170M3313
170M3363
103
170M3314
170M3364
170M3315
170M3365
170M3316
170M3366
170M3317
170M3367
102
170M3318
170M3368
170M3319
170M3369
170M3320
170M3370
170M3321
170M3371
101
170M4308
170M4358
170M4309
170M4359
170M4310
170M4360
0
10
170M4311
170M4361
170M4312
170M4362
170M4313
170M4363
170M4314
170M4364
101
170M4315
170M4365
170M4316
170M4366
170M4317
170M4367
170M4318
170M4368
2
10
170M5308
170M5358
170M5309
170M5359
170M5310
170M5360
170M5311
170M5361
103
170M5312
170M5362
170M5313
170M5363
170M5314
170M5364
170M5315
170M5365
4
1x10
1x102 170M5366
170M5316
170M6308
170M6358
170M6309
170M6359
170M6310
170M6360
170M6311
170M6361
170M6312
170M6362
170M6313
170M6363
170M6314
170M6364
170M6315
170M6365
170M6316
170M6366
170M6317
170M6367
170M6318
170M6368
High speed
fuses
1007July 2015
Eaton.com/bussmannseries
6-37
Time-current curve
Time-current curve
200A
250A
315A
350A
400A
450A
500A
550A
630A
700A
800A
900A
104
103
102
A
A
101
100
101
102
103
1x104
1x102
103
104
105
104
105
630A
550A 500A
450A
400A
350A
315A
250A
200A
160A
125A
100A
80A
63A
50A
40A
105
103
2x10
A
2
1x102
103
104
105
Prospective Short-Circuit Current Symmetrical RMS
250A
200A
103
A
2
1x102
103
6-38
900A
700A
550A
450A
350A
104
2x10
106
Eaton.com/bussmannseries
104
105
106
800A
630A
500A
400A
315A
Time-current curve
104
103
102
102
A
A
Virtual Pre-Arcing Time In Seconds
A
101
100
101
101
100
101
102
102
103
103
1x102
103
104
1x104
105
103
104
Prospective Current In Amps RMS
105
1250A
1000A
800A
630A
500A
400A
105
1100A
900A
700A
550A
450A
1800A
1500A
1250A
1000A
800A
630A
500A
105
2000A
1600A
1400A
1100A
900A
700A
550A
104
104
2x103
1x102
High speed
fuses
106
104
103
1x104
500A
550A 630A
700A 800A
900A 1000A
1100A
1250A
1400A 1500A
1600A 1800A
2000A
Time-current curve
400A
450A
500A
550A
630A
700A
800A
900A
1000A 1100A
1250A
A
1x103
104
105
106
Prospective Short-Circuit Current Symmetrical RMS
107
2x10
A
3
1x103
104
105
106
Prospective Short-Circuit Current Symmetrical RMS
107
1007July 2015
Eaton.com/bussmannseries
6-39
Arc voltage
Specifications
Description: Square body DIN
43 620 blade style high speed
fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 690Vac (IEC)
700Vac (UL)
Amps: 40-1000A
IR: 200kA RMS Sym.
Agency information: CE, Designed and tested to IEC
60269: Part 4. UL Recognized E125085.JFHR2.
CSA, Class 53787, File 1422-30 with the exception of
catalog number 170M4867D.
Power losses
Electrical
characteristics
Total clearing I2t
Dimensions (mm)
Type DIN 1*, DIN 2, DIN 3
Size
1*
2
3
A
69
69
68
B
135
150
150
D
58
71
88
E
45
55
76
F
40
48
60
H
20
26
33
Indicator
H
D
6-40
1007July 2015
Eaton.com/bussmannseries
Catalog numbers
Catalog numbers
DIN Type T
indicator
for micro
170M3808D
170M3809D
170M3810D
170M3811D
170M3812D
170M3813D
170M3814D
170M3815D
170M3816D
170M3817D
170M3818D
170M3819D
170M4863D
170M4864D
170M4865D
170M4866D
170M4867D
170M5808D
170M5809D
170M5810D
170M5811D
170M5812D
170M5813D
170M5814D
170M5820D
170M5816D
170M5817D
170M6808D
170M6809D
170M6810D
170M6811D
170M6812D
170M6813D
170M6814D
170M6892D
170M8554D
170M8555D
170M8556D
170M8557D
Size
1*
Electrical characteristics
Rated
I2t (A2sec)
current
Clearing
RMS-amps Pre-arc
at 660V
40
40
285
50
78
550
63
120
850
80
185
1350
100
360
2600
125
550
3900
160
1150
8250
200
2300
16500
250
4350
31000
315
7300
52000
350
10000
73000
400
16000
115000
21500
155000
450
500
27000
190000
550
33500
240000
630
48500
345000
700
69500
495000
400
11000
79000
450
16000
115000
500
21500
155000
550
29000
215000
630
41000
295000
700
60500
430000
800
86000
610000
900
125000
895000
1000
180000 1300000
1100
245000 1750000
500
14000
99500
550
19500
140000
630
31000
220000
700
45000
320000
800
69500
490000
900
100000
720000
1000
140000
985000
1100
190000 1400000
1250
300000 2150000
1400
380000 2700000
1500
470000 3350000
1600
585000 4150000
Time-current curve
Rated current
The rated current of this fuse range has been given with
copper conductors that have a current density of 1.3A/mm2
(IEC 60269-4). For conductor cross section according to IEC
60269-1, the fuses must be derated. Please contact
Bussmann for application assistance.
1007July 2015
Eaton.com/bussmannseries
6-41
Time-current curve
Time-current curve
6-42
Eaton.com/bussmannseries
Arc voltage
Specifications
Description: Square body flush
end contact high speed fuses.
Dimensions: See dimensions
illustrations.
Ratings:
Volts: 690Vac
Amps: 1000-4000A
IR: 200kA RMS Sym.
Agency information: CE, Designed and tested to IEC
60269: Part 4. UL Recognized E125085.JFHR2.
Electrical
characteristics
Total clearing I2t
1.5
1.0
Power losses
1)
0.5
0.4
0.3
0.2
Eg
Dimensions - mm
Type 4B/-, 4BKN/-, 4G/-, 4GKN/-
Size
4B
4G
F (in)
M10 10 deep
1
2 -13 UNC-2B 10 deep
105
G
33
38
5
4
3
200
1.0
Kp
0.8
300
400
500
Eg
600 690
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
70
Ib
80 90 100%
UL
High speed
fuses
1.4
1.2
103
9
8
7
6
105
15
56
53
67
1007July 2015
Eaton.com/bussmannseries
6-43
Catalog numbers
Catalog
-BKN/Type K
indicator
for micro
170M7078
170M7079
170M7080
170M7081
170M7082
170M7083
170M7084
170M7085
170M7086
-B/visual
indicator
170M7058
170M7059
170M7060
170M7061
170M7062
170M7063
170M7064
170M7065
170M7066
numbers
-G/visual
indicator
170M7098
170M7099
170M7100
170M7101
170M7102
170M7103
170M7104
170M7105
170M7106
-GKN/Type K
indicator
for micro
170M7118
170M7119
170M7120
170M7121
170M7122
170M7123
170M7124
170M7125
170M7126
Size
Electrical characteristics
Watts loss
Norm. Liquid
cool.
cool.
175
315
195
355
205
375
220
405
245
445
275
495
305
555
325
585
355
640
104
1000A
1250A
1400A
1600A
2000A
2200A
2500A
3000A
3500A
4000A
Time-current curve
B
4000A
3500A
3000A
2500A
2200A
2000A
1600A
1400A
1250A
1000A
103
102
A
A
101
105
104
100
2x103
A
1x103
104
101
102
103
1x104
1x103
104
105
Prospective Current in Amps RMS
106
6-44
1007July 2015
105
106
Eaton.com/bussmannseries
107
Arc voltage
Specifications
Description: High speed
square body fuses, for the
protection of the power rectifier
section of the equipment.
Dimensions: See dimensions
illustrations.
Ratings:
Volts: 660Vac
Amps: 1000-4000A
IR: 300kA RMS Sym.
Agency information: CE, Designed and tested to IEC
60269: Part 4. UL Recognized E125085.JFHR2.
Size 24
Size 23
This curve gives the peak arc voltage, UL, which may
appear across the fuse during its operation as a function of
the applied working voltage Eg , (rms) at a power factor of
15%.
Electrical characteristics
Power losses
Size 23
Size 24
High speed
fuses
Size 24
Size 23
Watts loss at rated current is given in the electrical
characteristics. The curve allows the calculation of the power
losses at load currents lower than the rated current. The
correction factor, Kp, is given as a function of the RMS load
current, Ib, in % of the rated current.
Typical applications
Power converters/rectifiers
Reduced voltage starters
1007July 2015
Eaton.com/bussmannseries
6-45
6
Fuse
size
23
-BKE/55
Type K
indicator
-BU/55
visual
indicator
170M6858
170M6859
170M6860
170M6861
170M6862
170M6863
170M6864
170M6865
170M6866
170M6867
170M6868
170M6869
170M6870
170M6898
170M6899
170M6900
170M6901
170M6902
170M6903
170M6904
170M6905
170M6906
170M6907
170M6908
170M6909
170M6910
Catalog numbers:
Fuse
size
24
-BU/60
without
indicator
170M7138
170M7139
170M7140
170M7141
170M7142
170M7143
170M7144
170M7145
170M7146
170M7147
170M7148
170M7149
170M6878
170M6879
170M6880
170M6881
170M6882
170M6883
170M6884
170M6885
170M6886
170M6887
170M6888
170M6889
170M6890
170M6918
170M6919
170M6920
170M6921
170M6922
170M6923
170M6924
170M6925
170M6926
170M6927
170M6928
170M6929
170M6930
Catalog number
-BKN/60
-GU/60
Type K
without
indicator
indicator
-GKN/60
Type K
indicator
170M7158
170M7159
170M7160
170M7161
170M7162
170M7163
170M7164
170M7165
170M7166
170M7167
170M7168
170M7169
A2s @ 500V
Data Sheet: 170K6332
Catalog number
-BKN/55
-GU/55
Type K
visual
indicator
indicator
170M7198
170M7199
170M7200
170M7201
170M7202
170M7203
170M7204
170M7205
170M7206
170M7207
170M7208
170M7209
170M7218
170M7219
170M7220
170M7221
170M7222
170M7223
170M7224
170M7225
170M7226
170M7227
170M7228
170M7229
-GKE/55
Type K
indicator
170M6958
170M6959
170M6960
170M6961
170M6962
170M6963
170M6964
170M6965
170M6966
170M6967
170M6968
170M6969
170M6970
Rated
voltage
(V)
690
500
-GKN/55
Type K
indicator
170M6938
170M6939
170M6940
170M6941
170M6942
170M6943
170M6944
170M6945
170M6946
170M6947
170M6948
170M6949
170M6950
Rated
voltage
(V)
660
600
550
Electrical characteristics
2
2
Rated
I t (A sec)
current
Clearing
RMS-amp
Pre-arc
at 660V
1000
79,000
530,000
1100
95,000
635,000
1250
155,000
1,050,000
1400
200,000
1,350,000
1500
240,000
1,650,000
1600
315,000
2,150,000
1800
450,000
3,050,000
2000
625,000
4,200,000
2200
805,000
5,400,000
2500
1,250,000
8,350,000
3000
2,250,000
15,500,000
3500
3,450,000
21,000,000
4000
5,000,000
27,500,000
Electrical characteristics
2
2
Rated
I t (A sec)
current
Clearing at
RMS-amp
Pre-arc
660V
2000
340000
2300000
2500
650000
4350000
3000
1100000
7300000
3500
1800000
12000000
4000
2700000
18000000
4500
3800000
25500000
5000
5450000
36500000
5500
7400000
49500000
6000
9600000
64000000
6500
12500000
83000000
7000
15000000
100000000
93000000
7500
18500000
Watt
loss
(W)
170.0
185.0
190.0
210.0
215.0
220.0
230.0
240.0
255.0
265.0
285.0
315.0
340.0
Watts
loss
(W)
340
390
430
460
490
520
540
560
580
600
630
660
Dimensions - mm
Size 23
Size 24
Type BU/ 55, - BKE/ 55, - BKN/ 55, - GU/ 55, - GKE/ 55, - GKN/ 55
Type BU/ 55, - BKE/ 55, - BKN/ 55, - GU/ 55, - GKE/ 55, - GKN/ 55
Size
23G
23B
6-46
Size
24BKN
A
2x2 M10
24GKN
/ 16UNC-2B
3 8
1007July 2015
A
2x3 M12
Eaton.com/bussmannseries
Time-current curve
Time-current curve
1007July 2015
Eaton.com/bussmannseries
6-47
Arc voltage
Specifications
Description: Square body DIN43
620 blade style high speed fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 690Vac (IEC)
Amps: 10-800A
IR: 300kA RMS Sym.
Agency information: CE, Designed and tested to IEC
60269: Part 4. UL Recognized E125085.JFHR2.
characteristics
Total clearing I t
1,5
1,0
0,5
0,4
0,3
0,2
200
300
400
500
600
8
7
6
5
4
3
200
300
400
Eg
700
1,0
A
49
68
68
68
B Max
78.5
135
150
150
1 mm = 0.0394 1 = 25.4 mm
6-48
D Max
60
66
74
89
E
30
52
60
75
F Min
35
40
48
60
Eg
700
0,4
0,3
0,2
0,15
0,1
30
40
50
60
Typical applications
DC common bus
DC drives
Power converters/rectifiers
Reduced voltage starters
H
15
20
25
32
1007July 2015
70
Size
00
1
2
3
600
Kp
0,8
0,7
0,6
0,5
Dimensions - mm
Type DIN 00, DIN 1, DIN 2, DIN 3
500
Power losses
Electrical
3
UL
2,5
2
1,8
1,6
1,4
1,2
103
Eaton.com/bussmannseries
80 90
Ib
100%
Catalog numbers
Catalog
numbers
Type T
indicator
for micro
170M2691
170M2692
170M2693
170M2694
170M2695
170M2696
170M2697
170M2698
170M2699
170M2700
170M2701
170M2702
170M4176
170M4177
170M4178
170M4179
170M4180
170M4181
170M4182
170M4183
170M4184
170M4185
170M4186
170M5881
170M5882
170M5883
170M5884
170M5885
170M5886
170M5887
170M5888
170M5889
170M6080
170M6081
170M6082
170M6083
170M6084
170M6085
170M6086
170M6087
Size
00
RMS
amp
rating*
10
16
20
25
32
40
50
63
80
100
125
160
50
63
80
100
125
160
200
250
315
350
400
200
250
315
350
400
450
500
550
630
350
400
450
500
550
630
700
800
Electrical characteristics
Watts
loss
3.5
5.5
6
8
9
10
11
14
16
19
23
29
12
15
17
20
23
28
31
35
41
45
48
33
40
46
50
53
59
66
70
79
55
59
62
67
70
85
93
99
High speed
fuses
*The RMS amp rating of this fuse range is given with open fuse bases connected to copper
conductors according to IEC 60269, Part 1, table 10. When used in enclosed fuse bases/
disconnects, derating factors have to be observed.
Please contact Eaton for application assistance.
Watts loss provided at rated current.
Microswitch ordered separately. See accessories on page 6-92 and 6-93.
For fuse curves see pages 6-50 and 6-51.
1007July 2015
Eaton.com/bussmannseries
6-49
Time-current curve
Time-current curve
104
103
103
102
102
10
1s
400A
315A
200A
125A
103
10-4
5x101
104
103
104
5x104
160A
125A100A
80A 63A
50A 40A
32A 5A
2
20A 16A
10A
10
103
103
104
Amp
105
105
102
102
350A
250A
160A
102
6-50
10-2
10-3
10-4
10
2x102
10
80A
10-3
10-1
50A
125A
80A
50A
32A
20A
10A
10-2
1s
100A
160A
100A
63A
40A
25A
10-1
10
63A
104
16A
A
400A 350
315A250A
200A 160A
104
125A100A
80A 63A
50A
103
105
2x102
10
1007July 2015
Eaton.com/bussmannseries
102
103
104
Amp
105
Time-current curve
Time-current curve
104
103
103
102
102
10
1s
10-2
1s
10-1
10-2
10-3
10-3
10-4
102
103
104
105
10-4
102
104
105
105
105
630A
0A
550A 50 A
0
450A 10
5A
350A 31
250A 200A
104
103
103
104
105
Amp
106
103
2x102
102
700A
550A
450A
350A
630A 550A
500A 450A
400A
350A
315A
250A
10-1
10
800A
630A
500A
400A
104
200A
800A
0A
700A 63A
0
550A 0 0A
450A 40
350A
104
103
2x102
102
103
104
105
1007July 2015
Eaton.com/bussmannseries
Amp
106
6-51
Arc voltage
Specifications
Description: Square body DIN 43
653 stud-mount high speed fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 1000Vac (20-250A)
900Vac (315A)
2
Amps: 20-315A
IR: 150kA RMS Sym.
Agency information: CE, Designed and tested to
IEC 60269: Part 4. UL Recognized E125085.JFHR2.
CSA Class 53787, File 1422-30 with the exception of catalog
number 170M4815.
Electrical
characteristics
1,5
Dimensions - mm
Type 00TN/80 00/80
Size
00/80
00TN/80
Max A
54
54
B
98
98
6-52
C
78
78
D
51
51
1,0
0,4
0,3
200
400
600
800
Max E
30
30
Power losses
0,5
0,2
F
28
28
67
1000
Eg
8
7
6
5
4
3
1,0
200
0,8
0,7
0,6
0,5
400
800
Eg
0,3
0,2
0,15
0,1
30
40
50
60
70
Eaton.com/bussmannseries
1000
0,4
1007July 2015
600
Kp
Typical applications
DC common bus
DC drives
Power converters/rectifiers
Reduced voltage starters
H
10
10
3
UL
2,5
2
1,8
1,6
1,4
1,2
103
80
Ib
90 100%
Catalog numbers
Electrical characteristics
00/80
00TN/80
I2t (A2 sec)
visual
Type T
Rated
Clearing
indicator for indicator for
Rated
current
at rated Watts
micro
micro
Size voltage RMS amps Pre-arc
voltage loss
170M4802 170M4822
1000
20
20
140
5
170M4803 170M4823
1000
25
30
210
7
170M4804 170M4824
1000
32
55
390
9
170M4805 170M4825
1000
35
69
500
10
170M4806 170M4826
1000
40
100
690
11
170M4807 170M4827
1000
50
170
1200
13
170M4808 170M4828
1000
63
280
2000
18
1000
80
500
3500
22
170M4809 170M4829 00
170M4810 170M4830
1000
100
950
6850
25
170M4811 170M4831
1000
125
1500
11500
33
170M4812 170M4832
1000
160
3000
22000
37
170M4813 170M4833
1000
200
5600
40500
40
170M4814 170M4834
1000
250
10000
74000
48
170M4815 170M4835
900
315
18000 115000
58
Not CSA rated.
Watts loss provided at rated current.
Microswitch ordered separately. See accessories on page 6-92 and 6-93.
103
102
10
1s
315A *
10-1
200A
125A
50A
80A
35A
25A
250A
160A
100A
63A
20A
40A
32A
Catalog numbers
10-2
10-3
10-4
10
103
102
104
104
315A
250A
200A160A
125A 100A
80A 63A
50A 40A
35A 32A
25A 20A
103
102
2x10
10
102
103
104
Prospective Short-Circuit
Prospective
Short-Circuit Current
Current symmetrical
SymmetricalRMS
RMS
Amp
105
1007July 2015
Eaton.com/bussmannseries
6-53
High speed
fuses
Arc voltage
Specifications
Description: Square body mount
high speed fuses.
Dimensions: See dimensions
illustrations.
Ratings:
Volts: 1000Vac.
Amps: 50-1400A
IR: 125kA RMS Sym.
Agency information: CE, Designed and tested to IEC
60269: Part 4. UL Recognized E125085.JFHR2.
Power losses
Electrical
characteristics
Total clearing I2t
1,5
1,0
0,5
0,4
0,3
0,2
500
600
700
800
900
Eg
1000
3
UL
2,5
2
1,8
1,6
1,4
1,2
103
8
7
6
5
4
3
500
1,0
0,8
0,7
0,6
0,5
600
700
800
900
Eg
Kp
0,4
0,3
0,2
0,15
0,1
30
40
50
60
70
80
Ib
90 100%
Dimensions - mm
Type KN/110
Size
1*KN/110
1KN/110
2KN/110
3KN/110
A
80
80
80
81
B
138
138
138
139
C
108
108
108
108
Max D1 E
61
43
69
51
77
59
92
74
G
6
6
6
6
H
22
25
25
30
Type TN/110
Size
A
1*TN/110 80
1TN/110 80
2TN/110 80
3TN/110 81
1mm = 0.0394
I
11
11
11
11
Type-TN/110
Type-KN/110
6-54
B
C
138
108
138
108
138
108
139
108
/ 1 = 25.4mm
1007July 2015
Eaton.com/bussmannseries
1000
Max D2 E
61
43
69
51
75
59
90
74
G
6
6
6
6
H
22
25
25
30
I
11
11
11
11
Size
1*
Rated
voltage
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
900
Electrical
Rated
current
RMS
amps
50
63
80
100
125
160
200
250
315
350
400
160
200
250
315
350
400
450
500
550
630
250
315
350
400
450
500
550
630
700
800
315
350
400
450
500
550
630
700
800
900
1000
1100
1250
1400
characteristics
I2t (A2 Sec)
Clearing
at rated
Pre-arc
voltage
135
815
215
1300
460
2750
860
5100
1450
8600
2850
17500
4950
29500
9550
57000
21500
130000
29000
175000
42000
250000
2200
13500
4150
24500
7750
46000
16500
98500
21500
130000
31000
185000
44500
265000
63000
375000
84500
500000
125000
755000
6750
40000
13500
81500
16500
99000
26000
155000
35500
210000
49500
295000
66000
390000
93500
555000
130000
770000
195000
1200000
9200
54500
13000
77500
19000
115000
27000
160000
37500
225000
52000
310000
82500
490000
115000
700000
170000
1050000
250000
1500000
340000
2050000
460000
2750000
575000
3400000
795000
4200000
Watts
loss
20
25
30
35
40
45
48
50
60
65
70
40
45
52
60
65
70
80
85
90
98
65
75
80
85
90
95
100
110
115
125
90
95
105
107
110
115
120
125
135
145
150
155
175
185
1007July 2015
High speed
fuses
Catalog numbers
-KN/110
-TN/110
Type K
Type T
indicator for
indicator for
micro
micro
170M3965
170M3981
170M3966
170M3982
170M3967
170M3983
170M3968
170M3984
170M3969
170M3985
170M3970
170M3986
170M3971
170M3987
170M3972
170M3988
170M3973
170M3989
170M3974
170M3990
170M3975
170M3991
170M4965
170M4980
170M4966
170M4981
170M4967
170M4982
170M4968
170M4983
170M4969
170M4984
170M4970
170M4985
170M4971
170M4986
170M4972
170M4987
170M4973
170M4988
170M4974
170M4989
170M5966
170M5981
170M5967
170M5982
170M5968
170M5983
170M5969
170M5984
170M5970
170M5985
170M5971
170M5986
170M5972
170M5987
170M5973
170M5988
170M5974
170M5989
170M5975
170M5990
170M8614
170M8629
170M8615
170M8630
170M8616
170M8631
170M8617
170M8632
170M8618
170M8633
170M8619
170M8634
170M8620
170M8635
170M8621
170M8636
170M8622
170M8637
170M8623
170M8638
170M8624
170M8639
170M8625
170M8640
170M8626
170M8641
170M8627
170M8642
Catalog numbers
Eaton.com/bussmannseries
6-55
Arc voltage
Specifications
Description: Square body flush
end contact high speed fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 1000Vac.
Amps: 50-1400A
IR: 150kA (Est. 300kA) RMS Sym.
Agency information: CE, Designed and tested to IEC
60269: Part 4. UL Recognized E125085.JFHR2.
Power losses
Electrical
characteristics
Total clearing I2t
1,5
1,0
0,5
0,4
0,3
0,2
500
600
700
800
900
Eg
1000
3
UL
2,5
2
1,8
1,6
1,4
1,2
103
8
7
6
5
4
3
500
1,0
0,8
0,7
0,6
0,5
600
Size
A
B
1*BKN/75+GKN/75 72.5
74
1BKN/75+GKN/75
73.2
74
2BKN/75+GKN/75
73.2
74.4
3BKN/75+GKN/75
73.3
75.4
3BKN/90+GKN/90
80.3
91.4
* Valid for fuses type GKN/-.
1mm = 0.0394 / 1 = 25.4mm
6-56
800
900
Eg
0,4
0,3
0,2
0,15
0,1
30
40
50
60
70
80
F
M8
M8
M10
M12
M12
F* (in)
5
16 18 UNC-2B
5
16 18 UNC-2B
3
8 16 UNC-2B
1
2 13 UNC-2B
1
2 13 UNC-2B
Min G
5
8
10
10
10
1007July 2015
H
17.5
20
24
30
30
Eaton.com/bussmannseries
Ib
90 100%
1000
Kp
Dimensions - mm
Type BKN/- and GKN/-
700
Catalog numbers
Rated
voltage
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
900
Electrical characteristics
I2t (A2 sec)
Rated
Clearing
current
at rated
RMS-amps Pre-arc
voltage
50
135
815
63
215
1300
80
460
2750
100
860
5100
125
1450
8600
160
2850
17500
4950
29500
200
250
9550
57000
315
21500
130000
350
29000
175000
400
42000
250000
160
2200
13500
200
4150
24500
250
7750
46000
315
16500
98500
350
21500
130000
400
31000
185000
450
44500
265000
500
63000
375000
550
84500
500000
630
125000
755000
250
6750
40000
315
13500
81500
350
16500
99000
400
26000
155000
450
35500
210000
500
49500
295000
550
66000
390000
630
93500
555000
700
130000
770000
800
195000
1200000
315
9200
54500
350
13000
77500
400
19000
115000
450
27000
160000
500
37500
225000
550
52000
310000
630
82500
490000
700
115000
700000
800
170000
1050000
900
250000
1500000
1000
340000
2050000
1100
460000
2750000
1250
575000
3400000
1400
795000
4200000
**Overall length is 90mm, for all other fuses the overall length is 75mm.
Watts loss provided at rated current.
Microswitch ordered separately. See accessories on page 6-92 and 6-93.
For fuse curves see pages 6-60 and 6-61.
1007July 2015
6-57
Watts
loss
20
25
30
35
40
45
48
50
60
65
70
40
45
52
60
65
70
80
85
90
98
65
75
80
85
90
95
100
110
115
125
90
95
105
107
110
115
120
125
135
145
150
155
175
185
High speed
fuses
Catalog numbers
-BKN/-GKN/Type K
Type K
indicator for indicator for
micro
micro
Size
170M3951 170M3921
170M3952 170M3922
170M3953 170M3923
170M3954 170M3924
170M3955 170M3925
170M3956 170M3926
1*
170M3957 170M3927
170M3958 170M3928
170M3959 170M3929
170M3960 170M3930
170M3961 170M3931
170M4951 170M4921
170M4952 170M4922
170M4953 170M4923
170M4954 170M4924
170M4955 170M4925
1
170M4956 170M4926
170M4957 170M4927
170M4958 170M4928
170M4959 170M4929
170M4960 170M4930
170M5952 170M5922
170M5953 170M5923
170M5954 170M5924
170M5955 170M5925
170M5956 170M5926
170M5957 170M5927
2
170M5958 170M5928
170M5959 170M5929
170M5960 170M5930
170M5961 170M5931
170M8600 170M8500
170M8601 170M8501
170M8602 170M8502
170M8603 170M8503
170M8604 170M8504
170M8605 170M8505
170M8606 170M8506
3
170M8607 170M8507
170M8608 170M8508
170M8609 170M8509
170M8610 170M8510
170M8611 170M8511
170M8612** 170M8512**
170M8613** 170M8513**
Eaton.com/bussmannseries
Arc voltage
Specifications
Description: Square body US
style high speed fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 1000Vac.
Amps: 50-1400A
IR: 150kA RMS Sym.
Agency information: CE, Designed and tested to IEC
60269: Part 4. UL Recognized E125085.JFHR2.
Dimensions - mm
Type FKE/115
Size
1*FKE/115
1FKE/115
2FKE/115
3FKE/115
B
156
160
160
159
C1
130
127
127
128
6-58
C2
101
102
102
101
1,5
Power losses
1,0
0,5
0,4
0,3
0,2
500
600
700
800
900
D
59
69
77
92
E
45
53
61
76
H
20
25
25
36
I
10
14
14
16
8
7
6
5
4
3
Electrical
characteristics
Total clearing I2t
3
UL
2,5
2
1,8
1,6
1,4
1,2
103
Eg
1000
1007July 2015
500
1,0
0,8
0,7
0,6
0,5
600
700
800
900
1000
Kp
0,4
0,3
0,2
0,15
0,1
30
40
50
60
70
80
Typical applications
DC common bus
DC drives
Power converters/rectifiers
Reduced voltage starters
Ib
90 100%
Eaton.com/bussmannseries
Eg
Catalog numbers
Size
1*
Electrical characteristics
Rated
current
RMS-amps
50
63
80
100
125
160
200
250
315
350
400
160
200
250
315
350
400
450
500
550
630
250
315
350
400
450
500
550
630
700
800
315
350
400
450
500
550
630
700
800
900
1000
1100
1250
1400
Watts
loss
20
25
30
35
40
45
48
50
60
65
70
40
45
52
60
65
70
80
85
90
98
65
75
80
85
90
95
100
110
115
125
90
95
105
107
110
115
120
125
135
145
150
155
175
185
High speed
fuses
Catalog numbers
-FKE/115
Type K
indicator for
micro
170M3531
170M3532
170M3533
170M3534
170M3535
170M3536
170M3537
170M3538
170M3539
170M3540
170M3541
170M4531
170M4532
170M4533
170M4534
170M4535
170M4536
170M4537
170M4538
170M4539
170M4540
170M5531
170M5532
170M5533
170M5534
170M5535
170M5536
170M5537
170M5538
170M5539
170M5540
170M8531
170M8532
170M8533
170M8534
170M8535
170M8536
170M8537
170M8538
170M8539
170M8540
170M8541
170M8542
170M8543
170M8544*
1007July 2015
Eaton.com/bussmannseries
6-59
Time-current curve
Time-current curve
104
103
102
103
104
5x104
10-4
102
104
105
104
103
103
104
105
Amp
106
103
105
630A 550A
A
500A 450
0A
400A 35
A
5
1
3
250A
200A 160A
104
103
2x102
102
103
1007July 2015
104
105
6-60
550A
450A
10-2
10-3
2x102
102
250A
10-4
5x101
350A
10-3
10-1
160A
350A
250A
100A
160A
63A
10-2
1s
630A
500A
400A
315A
400A
315A
200A
125A
80A
10-1
10
200A
1s
50A
102
Eaton.com/bussmannseries
Amp
106
Time-current curve
Time-current curve
104
104
103
103
10
1s
700A
550A
450A
350A
10-1
800A
630A
500A
400A
315A
10-2
10-3
10
1s
10-1
10-2
10-3
10-4
102
103
104
105
10-4
102
104
105
800A
630A
500A
400A
315A
700A
550A
450A
350A
250A
104
103
103
104
105
Amp
106
105
*11205000AA
A
1400 A
1100
900A
700A
550A
450A
350A
800A
630A
500A
400A
315A
104
103
2x102
102
103
104
105
Amp
106
1007July 2015
Eaton.com/bussmannseries
6-61
High speed
fuses
105
103
2x102
102
*
1400A 1250A
1100A 1000A
900A 800A
700A 630A
550A 500A
450A 400A
350A 315A
102
250A
102
Arc voltage
Specifications
Description: Square body DIN
43 620 blade style high speed
fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 1000Vac (IEC)
Amps: 1000-2700A
IR: 125kA RMS Sym.
Agency information: CE, designed and tested to IEC
60269: Part 4. UL Recognized E125085.JFHR2.
Power losses
Electrical
characteristics
Total clearing I2t
Catalog numbers
Fuse
size
6-62
Catalog number
-SBKN/90
-BKN/95
Type K
Type K
indicator
indicator
170M7636
170M7639
170M7963
170M7090
170M7640
170M7658
170M7542
170M7031
170M7548
170M7034
170M7544
170M7035
170M7036
170M7037
Rated
voltage
(V)
1000
Electrical characteristics
2
2
Rated
I t (A sec)
current
Clearing
RMS-amp
Pre-arc
at 1000V
1000
180000
1100000
1100
250000
1500000
1500
600000
3600000
1700
850000
5000000
2000
1450000
8600000
2200
2000000
12000000
2500
3000000
18000000
2700
3700000
22000000
1007July 2015
Watt
loss
(W)
195
200
250
260
270
280
295
310
Eaton.com/bussmannseries
Dimensions - mm
Type 4BKN/ 95
Type 4SBKN/ 95
High speed
fuses
1007July 2015
Eaton.com/bussmannseries
6-63
6-64
1007July 2015
Eaton.com/bussmannseries
Arc voltage
Specifications
Description: High speed square
body fuses, for the protection of
the power rectifier section of the
equipment.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 1000Vac
Amps: 2000-5000A
IR: 300kA RMS Sym.
Agency information: CE, designed and tested to IEC
60269: Part 4. UL Recognized E125085.JFHR2.
4200-5000A
2000-3500A
This curve gives the peak arc voltage, UL, which may
appear across the fuse during its operation as a function of
the applied working voltage Eg , (rms) at a power factor of
15%.
Electrical characteristics
Total clearing I2t
2000-3500A
4200-5000A
Power losses
Catalog numbers
Cat. number
Rated
-BKN/85
Fuse
voltage
Type K
size
(V)
indicator
24
170M7608
170M7680
170M7567
170M7568
170M7569
170M7498
170M7488
170M7622
1000
Typical applications
Power converters/rectifiers
Reduced voltage starters
Electrical characteristics
2
2
Rated
I t (A sec)
current
Clearing at
RMS-amp
Pre-arc
1000V
2000
3000
3200
3500
4000
4200
4500
5000
885000
2900000
3300000
4500000
6800000
8000000
10000000
14000000
5700000
19000000
20000000
27000000
40000000
47500000
59000000
82500000
High speed
fuses
Dimensions - mm
Watt
loss
(W)
345
430
440
450
475
485
495
540
1007July 2015
Eaton.com/bussmannseries
6-65
Time-current curve
Time-current curve
6-66
Eaton.com/bussmannseries
Arc voltage
Specifications
Description: Square body DIN
43 653 stud-mount high speed
fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 1250Vac (IEC)
1300Vac (UL)
Amps: 50-1400A
IR: 100kA RMS Sym.
Agency information: CE, Designed and tested to IEC
60269: Part 4. UL Recognized E125085.JFHR2, CSA
Certified: Class 53787, File 1422-30.
Power losses
Electrical
characteristics
1.5
K
1.25
1.0
amperages:.
Size
Amps.
1*
400A
1
500-630A
2
630-1000A
3
800-1400A
A
80
80
80
81
B
138
138
138
139
D**
58
66
75
90
E
45
53
61
76
**Microswitch.
1mm = 0.0394 / 1 = 25.4mm
H
20
25
25
30
1.4
103
8
6
5
4
3
400
1.0
Kp
0.8
600
800
Eg
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
70
Ib
80 90 100%
Typical applications
DC common bus
DC drives
Power converters/rectifiers
Reduced voltage starters
Size
1*
1
2
3
108
A
A
80
80
80
81
B
138
138
138
139
D
58
66
75
90
E
45
53
61
76
High speed
fuses
UL
1.8
Dimensions - mm
Size
1*
1
2
3
3
2.5
H
20
25
25
30
H
11
D
E
6
E
11
B
1007July 2015
Eaton.com/bussmannseries
6-67
Catalog numbers
-TN/110
-/110
Type T
visual
indicator
indicator
for micro
170M3138
170M3188
170M3139
170M3189
170M3140
170M3190
170M3141
170M3191
170M3142
170M3192
170M3143
170M3193
170M3144
170M3194
170M3145
170M3195
170M3146
170M3196
170M3147
170M3197
170M3148
170M3198
170M4138
170M4188
170M4139
170M4189
170M4140
170M4190
170M4191
170M4141
170M4142
170M4192
170M4143
170M4193
170M4144
170M4194
170M4145
170M4195
170M4146
170M4196
170M4147
170M4197
170M5138
170M5188
170M5139
170M5189
170M5140
170M5190
170M5141
170M5191
170M5142
170M5192
170M5143
170M5193
170M5144
170M5194
170M5145
170M5195
170M5146
170M5196
170M5147
170M5197
170M5148
170M5198
170M5149
170M5199
170M5150
170M5200
170M6138
170M6188
170M6139
170M6189
170M6140
170M6190
170M6141
170M6191
170M6142
170M6192
170M6143
170M6193
170M6144
170M6194
170M6145
170M6195
170M6146
170M6196
170M6147
170M6197
170M6148
170M6198
170M6149
170M6199
170M6150
170M6200
170M6151
170M6201
Catalog numbers
-KN/110
Type K
indicator
for micro
170M3238
170M3239
170M3240
170M3241
170M3242
170M3243
170M3244
170M3245
170M3246
170M3247
170M3248
170M4238
170M4239
170M4240
170M4241
170M4242
170M4243
170M4244
170M4245
170M4246
170M4247
170M5238
170M5239
170M5240
170M5241
170M5242
170M5243
170M5244
170M5245
170M5246
170M5247
170M5248
170M5249
170M5250
170M6238
170M6239
170M6240
170M6241
170M6242
170M6243
170M6244
170M6245
170M6246
170M6247
170M6248
170M6249
170M6250
170M6251
Size
1*
Rated
current
RMS-amps
50
63
80
100
125
160
200
250
315
350
400
160
200
250
315
350
400
450
500
550
630
250
280
315
350
400
450
500
550
630
700
800
900
1000
315
350
400
450
500
550
630
700
800
900
1000
1100
1250
1400
Electrical characteristics
I2t (A2 sec)
Clearing
Clearing
Pre-arc
at 1000V
at 1250V
135
815
1100
215
1300
1750
420
2500
3350
750
4450
5950
1450
9000
11500
2600
16000
21000
5150
31000
41000
9200
54500
73000
18500
115000
150000
27000
165000
220000
53000
265000
335000
1900
11500
15500
3800
22500
30000
7750
46000
61500
15000
90000
120000
20000
125000
165000
29500
175000
235000
42000
250000
335000
69500
340000
435000
95000
465000
590000
130000
660000
6500
38500
51500
9350
55500
74500
13000
77500
105000
16500
97500
135000
23000
140000
180000
34000
205000
270000
48000
285000
380000
62000
370000
495000
115000
575000
730000
160000
795000
1050000
245000
1200000
1550000
360000
1750000
480000
2350000
9500
58000
77500
13500
81500
110000
19500
120000
160000
31000
185000
245000
39000
235000
310000
55000
325000
435000
83500
495000
665000
115000
705000
940000
205000
995000
1300000
305000
1500000
1900000
450000
2150000
2750000
575000
2800000
3600000
810000
3950000
1250000
6000000
6-68
1007July 2015
Watts
loss
15
20
25
30
35
40
45
55
60
65
70
45
50
60
65
70
75
80
85
95
100
65
70
75
80
85
90
95
100
110
115
120
125
135
85
90
95
100
105
110
115
120
125
130
135
140
145
150
Eaton.com/bussmannseries
Arc voltage
Specifications
Description: Square body flush
end contact high speed fuses.
Dimensions: See dimensions
illustrations.
Ratings:
Volts: 1250Vac (IEC)
1300Vac (UL)
Amps: 50-1400A
IR: 100kA RMS Sym.
Agency information: CE, Designed and tested to IEC
60269: Part 4. UL Recognized E125085.JFHR2, CSA
Certified: Class 53787, File 1422-30.
Electrical
characteristics
Total clearing I2t
Size
1*
1*
1
1
2
2
2
3
3
3
Type
BKN + GKN/75
BKN/80
BKN + GKN/75
BKN/80
BKN + GKN/75
BKN/80
BKN + GKN/90
BKN + GKN/75
BKN/80
BKN + GKN/90
A
74
80
74
80
74
80
80
74
81
81
B
75
81
75
81
75
81
91
76
83
91
D
59
59
69
69
77
77
77
92
92
92
1.5
K
1.25
1.0
0.5
0.4
0.3
0.2
Eg
E
45
45
53
53
61
61
61
76
76
76
F
M8
M8
M8
M8
M10
M10
M10
M12
M12
M12
F** (in)
16 - 18 UNC-2B
16 - 18 UNC-2B
8 - 16 UNC-2B
8 - 16 UNC-2B
2 - 13 UNC-2B
3
1
2 - 13 UNC-2B
G
5
5
8
8
10
10
10
10
10
10
UL
1.8
1.4
103
8
6
5
4
3
400
1.0
Kp
0.8
600
800
Eg
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
70
Ib
80 90 100%
H
17
17
20
20
24
24
24
30
30
30
High speed
fuses
Dimensions - mm
Type -BKN/-, -GKN/-
Power losses
3
2.5
1007July 2015
Eaton.com/bussmannseries
6-69
Catalog numbers
-BKN/75
-BKN/80
Type K
Type K
indicator
indicator
for micro
for micro
170M3388 170M3438
170M3389 170M3439
170M3390 170M3440
170M3391 170M3441
170M3392 170M3442
170M3393 170M3443
170M3394 170M3444
170M3395 170M3445
170M3396 170M3446
170M3397 170M3447
170M3448
170M4388 170M4438
170M4389 170M4439
170M4390 170M4440
170M4391 170M4441
170M4392 170M4442
170M4393 170M4443
170M4394 170M4444
170M4395 170M4445
170M4396 170M4446
170M4397 170M4447
170M5388 170M5438
170M5389 170M5439
170M5390 170M5440
170M5391 170M5441
170M5392 170M5442
170M5393 170M5443
170M5394 170M5444
170M5395 170M5445
170M5396 170M5446
170M5397 170M5447
170M5398 170M5448
Catalog numbers
170M6338
170M6339
170M6340
170M6341
170M6342
170M6343
170M6344
170M6345
170M6346
170M6347
170M6348
170M6349
170M6538
170M6539
170M6540
170M6541
170M6542
170M6543
170M6544
170M6545
170M6546
170M6547
170M6548
170M6549
-BKN/90
Type K
indicator
for micro
170M5494
170M5495
170M5496
170M5497
170M5498
170M5499
170M5500
170M6494
170M6495
170M6496
170M6497
170M6498
170M6499
170M6500
170M6501
-GKN/75
Type K
indicator
for micro
170M3488
170M3489
170M3490
170M3491
170M3492
170M3493
170M3494
170M3495
170M3496
170M3497
170M4488
170M4489
170M4490
170M4491
170M4492
170M4493
170M4494
170M4495
170M4496
170M4497
170M5588
170M5589
170M5590
170M5591
170M5592
170M5593
170M5594
170M5595
170M5596
170M5597
170M5598
170M6588
170M6589
170M6590
170M6591
170M6592
170M6593
170M6594
170M6595
170M6596
170M6597
170M6598
170M6599
-GKN/90
Type K
indicator
for micro
170M5644
170M5645
170M5646
170M5647
170M5648
170M5649
170M5650
170M6644
170M6645
170M6646
170M6647
170M6648
170M6649
170M6650
170M6651
Rated
current
RMSSize amps
50
63
80
100
125
1*
160
200
250
315
350
400
160
200
250
315
350
1
400
450
500
550
630
250
280
315
350
400
450
2
500
550
630
700
800
900
1000
315
350
400
450
500
550
630
3
700
800
900
1000
1100
1250
1400
6-70
1007July 2015
Electrical characteristics
Pre-arc
135
215
420
750
1450
2600
5150
9200
18500
27000
53000
1900
3800
7750
15000
20000
29500
42000
69500
95000
130000
6500
9350
13000
16500
23000
34000
48000
62000
115000
160000
245000
360000
480000
9500
13500
19500
31000
39000
55000
83500
115000
205000
305000
450000
575000
810000
1250000
I2t (A2sec)
Clearing
at 1000V
815
1300
2500
4450
9000
16000
31000
54500
115000
165000
265000
11500
22500
46000
90000
125000
175000
250000
340000
465000
660000
38500
55500
77500
97500
140000
205000
285000
370000
575000
795000
1200000
1750000
2350000
58000
81500
120000
185000
235000
325000
495000
705000
995000
1500000
2150000
2800000
3950000
6000000
Clearing
at 1250V
1100
1750
3350
5950
11500
21000
41000
73000
150000
220000
335000
15500
30000
61500
120000
165000
235000
335000
435000
590000
51500
74500
105000
135000
180000
270000
380000
495000
730000
1050000
1550000
77500
110000
160000
245000
310000
435000
665000
940000
1300000
1900000
2750000
3600000
Eaton.com/bussmannseries
Watts
loss
15
20
25
30
35
40
45
55
60
65
70
45
50
60
65
70
75
80
85
95
100
65
70
75
80
85
90
95
100
110
115
120
125
135
85
90
95
100
105
110
115
120
125
130
135
140
145
150
Arc voltage
Specifications
Description: Square body US
style high speed fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 1250Vac (IEC)
1300Vac (UL)
Amps: 50-1400A
IR: 100kA RMS Sym.
Agency information: CE,
Designed and tested to IEC
60269: Part 4. UL Recognized
E125085.JFHR2, CSACertified:
Class 53787, File 1422-30.
Power losses
1.5
K
1.25
1.0
Electrical
characteristics
2
Total clearing I t
500-630A
630-1000A
800-1400A
3
2.5
UL
1.8
1.4
103
8
6
5
4
3
400
1.0
Kp
0.8
600
800
Eg
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
70
Ib
80 90 100%
Size
1*
1
2
3
B
156
160
160
159
C1
130
127
127
128
C2
101
102
102
101
D
59
69
77
92
E
45
53
61
76
H
20
25
25
36
I
10
14
14
16
C1
C2
High speed
fuses
Dimensions - mm
Type -FU/115, -FKE/115
1007July 2015
Eaton.com/bussmannseries
6-71
Catalog numbers
Catalog numbers
-FKE/115
-FU/115
Type K
without
indicator
indicator
for micro
170M3688 170M3738
170M3689 170M3739
170M3690 170M3740
170M3691 170M3741
170M3692 170M3742
170M3693 170M3743
170M3694 170M3744
170M3695 170M3745
170M3696 170M3746
170M3697 170M3747
170M4688 170M4738
170M4689 170M4739
170M4690 170M4740
170M4691 170M4741
170M4692 170M4742
170M4693 170M4743
170M4694 170M4744
170M4695 170M4745
170M4696 170M4746
170M4697 170M4747
170M5688 170M5738
170M5689 170M5739
170M5690 170M5740
170M5691 170M5741
170M5692 170M5742
170M5693 170M5743
170M5694 170M5744
170M5695 170M5745
170M5696 170M5746
170M5697 170M5747
170M5698 170M5748
170M5699 170M5749
170M5700 170M5750
170M6688 170M6738
170M6689 170M6739
170M6690 170M6740
170M6691 170M6741
170M6692 170M6742
170M6693 170M6743
170M6694 170M6744
170M6695 170M6745
170M6696 170M6746
170M6697 170M6747
170M6698 170M6748
170M6699 170M6749
170M6700 170M6750
170M6701 170M6751
Size
1*
Rated
current
RMS-amps
50
63
80
100
125
160
200
250
315
350
160
200
250
315
350
400
450
500
550
630
250
280
315
350
400
450
500
550
630
700
800
900
1000
315
350
400
450
500
550
630
700
800
900
1000
1100
1250
1400
Electrical characteristics
Pre-arc
135
215
420
750
1450
2600
5150
9200
18500
27000
1900
3800
7750
15000
20000
29500
42000
69500
95000
130000
6500
9350
13000
16500
23000
34000
48000
62000
115000
160000
245000
360000
480000
9500
13500
19500
31000
39000
55000
83500
115000
205000
305000
450000
575000
810000
1250000
Clearing
at 1250V
1100
1750
3350
5950
11500
21000
41000
73000
150000
220000
15500
30000
61500
120000
165000
235000
335000
51500
74500
105000
135000
180000
270000
380000
495000
730000
77500
110000
160000
245000
310000
435000
665000
940000
1300000
1900000
6-72
1007July 2015
Watts
loss
15
20
25
30
35
40
45
55
60
65
45
50
60
65
70
75
80
85
95
100
65
70
75
80
85
90
95
100
110
115
120
125
135
185
90
95
100
105
110
115
120
125
130
135
140
145
150
Eaton.com/bussmannseries
Time-current curve
Time-current curve
160A
200A
250A
315A
350A
400A
450A
500A 550A
630A
Size 1* 50-400A:1250V
104
103
102
A
A
101
100
101
102
103
1x104
105
103
400A
350A
315A
250A
200A
160A
125A
100A
80A
63A
50A
104
630A
550A
500A
450A
400A
350A
315A
250A
200A
160A
103
A
1x102
A
103
104
105
Prospective Short-Circuit Current Symmetrical RMS
106
2x10
1x102
103
104
105
Prospective Short-Circuit Current Symmetrical RMS
106
1007July 2015
Eaton.com/bussmannseries
6-73
High speed
fuses
105
104
2x102
103
104
Prospective Current In Amp RMS
1x102
Time-current curve
Time-current curve
250A
280A
315A 350A
400A
450A
500A 550A
630A
700A
800A
900A
1000A
104
103
102
A
A
101
100
101
102
103
1x104
1x102
103
104
Prospective Current In Amp RMS
105
104
103
2x102
A
1x102
103
104
105
Prospective Short-Circuit Current Symmetrical RMS
106
6-74
1007July 2015
Eaton.com/bussmannseries
Arc voltage
Specifications
Description: High speed
square body fuses, for the
protection of the power rectifier
section of the equipment.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 1250Vac (IEC)
Amps: 1400-2500A
IR: 125kA RMS Sym.
Agency information: CE, Designed and tested to IEC
60269: Part 4. UL Recognized E125085.JFHR2. CSA
Certified E125085.JFHR2.
Power losses
Electrical
characteristics
Total clearing I2t
High speed
fuses
Catalog numbers
Fuse
size
4
Catalog number
-BKN/105
-SBKN/105
Type K
Type K
indicator
indicator
170M7217
170M7597
170M7676
170M7532
170M7633
170M7592
170M7107
170M7595
170M7512
170M7510
170M7511
170M7976
170M7513
170M7546
170M7516
170M7978
Rated
voltage
(V)
1250
Electrical characteristics
2
2
Rated
I t (A sec)
current
Clearing
RMS-amp
at 1250V
Pre-arc
1400
800000
5000000
1500
1000000
6200000
1700
1400000
8700000
1800
1700000
11000000
2000
2300000
14500000
2200
3100000
19500000
2400
4000000
25000000
2500
4500000
28000000
Watt
loss
(W)
195
200
220
225
235
245
255
260
1007July 2015
Eaton.com/bussmannseries
6-75
Dimensions - mm
Type 4BKN/ 105
106.6
6-76
1007July 2015
Eaton.com/bussmannseries
Time-current curve
Time-current curve
1007July 2015
Eaton.com/bussmannseries
6-77
Arc voltage
Specifications
Description: High speed square
body fuses, for the protection of the
power rectifier section of the
equipment.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 1250Vac (IEC)
Amps: 630-2800A
IR: 125kA RMS Sym.
Agency information: CE, Designed and tested to IEC
60269: Part 4. UL Recognized.
Power losses
Electrical
characteristics
Total clearing I2t
Catalog numbers
Fuse
size
23
-BU/75
without
indicator
170M6775
170M6776
170M6777
170M6805
170M6778
170M6779
170M6780
170M6781
170M6782
170M6783
-BKE/75
Type K
indicator
170M6795
170M6796
170M6797
170M6807
170M6798
170M6799
170M6800
170M6801
170M6802
170M6803
Catalog number
-BKN/75
-BU/80
Type K
without
indicator
indicator
170M6785
170M6786
170M6787
170M6806
170M6788
170M6789
170M6790
170M6791
170M6792
170M6793
-BKE/80
Type K
indicator
-BKN/80
Type K
indicator
Rated
voltage
(V)
1250
170M6784
170M6815
170M6816
170M6817
170M6804
170M6833
170M6834
170M6835
170M6794
170M6827
170M6828
170M6829
1100
Electrical characteristics
2
2
Rated
I t (A sec)
current
Clearing at
RMS-amp
Pre-arc
1250V
630
38000
310000
700
54000
440000
800
78000
640000
900
120000
980000
1000
155000
1250000
1100
220000
1750000
1250
330000
2700000
1400
460000
3800000
1600
820000
5200000
1800
1200000
7600000
2000
1800000
11000000
2200
2300000
14500000
16000000
2500
3200000
2800
5000000
24000000
A2s @ 1000V
Data Sheet: 170K6638
6-78
1007July 2015
Eaton.com/bussmannseries
Watts
loss
(W)
170
180
190
200
210
220
230
240
250
260
270
280
290
300
Dimensions - mm
1007July 2015
Eaton.com/bussmannseries
6-79
Typical applications
AC and DC drives
High power converters/rectifiers
Dimensions - mm (in)
6-80
1007July 2015
Eaton.com/bussmannseries
Power losses
750Vdc 63-500A
Specifications
Description: High speed fuses, for the
protection of DC circuits in equipment.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 750Vdc
Amps: 63-500A
IR: 750Vdc IR: 100kA, L/R = 100 ms.
1000Vdc IR: 100kA, L/R = 40 ms
Agency information: Consult Eaton.
bulehighspeedtechnical@eaton.com
Electrical
characteristics
Arc voltage
Catalog numbers
Fuse
size
-BK/130
170E3577
170E3578
170E3579
170E3580
170E3581
170E5417
170E5418
170E8335
170E8336
170E8337
170E9681
-EK/-
170E3583
170E3584
170E3585
170E3586
170E3587
170E5420
170E5421
170E8345
170E8346
170E8347
170E9685
Electrical characteristics
Rated
Rated
Watt
voltage
current
loss
(Vdc)
RMS-amp
(W)
750
63
80
100
125
160
200
250
250
315
400
500
10.0
13.0
16.0
21.0
26.0
37.0
46.0
47.0
57.0
73.0
91.0
High speed
fuses
1*
Catalog numbers
1007July 2015
Eaton.com/bussmannseries
6-81
Dimensions - mm
Type BK/ 130
Size/
Size/Type
e/T
e/
/Ty
Type
1* BK/130
1 BK/130
2 BK/130
3 BK/130
A
129
130
130
131
B
43
51
59
74
D
61
69
77
90
Type EK/ -
Size/Type
1* EK/155
1 EK/165
2 EK/170
3 EK/170
6-82
1007July 2015
A
124
124
124
125
B
156
166
170
170
C
129
129
129
130
D
180
191
205
206
Eaton.com/bussmannseries
E
43
51
59
74
F
36
37
42
51
G
41
41
48
56
H
9
11
13
13
I
9
14
21
20
J
18
25
30
36
Time-current curve
Time-current curve
1007July 2015
Eaton.com/bussmannseries
6-83
Time-current curve
Time-current curve
6-84
1007July 2015
Eaton.com/bussmannseries
Power losses
1200Vdc 160-420A
Specifications
Description: High speed fuses that
provide superior protection in light and
heavy harsh DC traction applications as
1200Vdc and below circuits, and as DC
link/power converters.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 1200Vdc
Amps: 160-420A
IR: 1200Vdc = 100kA L/R: 15 ms.
Agency information: Consult Eaton.
bulehighspeedtechnical@eaton.com
Electrical
characteristics
Arc Voltage
2SKN / 140
-SKNB/140
Type K
indicator
170F8230
170F8231
170F8232
170F8233
170F8234
170F8235
Rated
voltage
(Vdc)
1200
Electrical characteristics
Max I2t (A2sec) @ 1000Vdc
Rated
current
RMS-amp
L/R = 15ms L/R = 45ms
160
12000
20000
200
20000
35000
250
43000
75000
315
87000
150000
400
180000
310000
420
215000
375000
Watts
loss
(W)
75.0
85.0
94.0
104.0
120.0
122.0
High speed
fuses
Fuse
type
Cat. numbers
Catalog numbers
Dimensions - mm
1007July 2015
Eaton.com/bussmannseries
6-85
6-86
1007July 2015
Eaton.com/bussmannseries
Power losses
2000Vdc 10-125A
Specifications
Description: High speed fuses for the
protection of DC circuits in equipment.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 2000Vdc
Amps: 10-125A
IR: 2000Vdc = 40kA @ L/R 30ms.
Agency information: Consult Eaton.
bulehighspeedtechnical@eaton.com
Electrical
characteristics
Arc voltage
Catalog Numbers
Fuse
type
(gR)
2000
10
16
20
25
32
40
50
63
80
7
11
13
17
22
27
34
43
50
Fuse
type
(aR)
1*SKN/246
Cat. number
Electrical characteristics
Watt
-SKN/246
Rated
Rated
loss
Type K
current
voltage
(W)
indicator
RMS-amp
(Vdc)
170E3937
20
13
170E3938
25
16
170E3939
32
20
170E3940
40
25
170E3941
2000
50
32
170E3942
63
40
170E3943
80
51
170E3944
100
64
170E3945
125
80
High speed
fuses
1*SKN/246
Cat. number
Electrical characteristics
Rated
-SKN/246
Rated
Watt
voltage
Type K
current
loss
(Vdc)
indicator
RMS-amp
(W)
170E3976
170E3970
170E3950
170E3951
170E3952
170E3953
170E3954
170E3955
170E3956
Dimensions - mm
1007July 2015
Eaton.com/bussmannseries
6-87
Time-current curve
Time-current curve
6-88
1007July 2015
Eaton.com/bussmannseries
4000Vdc 20-450A
Power losses
Specifications
Description: High speed fuses for the
protection of DC circuits in equipment.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 4000Vdc
Amps: 20-450A
IR: 60kA L/R: 25 ms.
Agency information: Consult Eaton.
bulehighspeedtechnical@eaton.com
Electrical
characteristics
Arc voltage
Typical applications
DC Common bus
DC Drives
Power converters/rectifiers
Reduced voltage starters
Fuse
type
1*SKN/394
2 SKN/394
2//2SKN/394
Cat. numbers
-SKN/394
Rated
Type K
voltage
indicator
(Vdc)
170E3914
170E3915
170E3916
170E3917
170E3918
170E3919
170E3984
170E3933
170E3922
170E8882
170E8883
170E8884
170E8885
170E8886
170E8887
170E8888
4000
High speed
fuses
Catalog numbers
Electrical characteristics
Rated
Watts
current
loss
RMS-amp
(W)
20
25
32
40
50
63
80
100
125
160
200
250
315
350
400
450
23
28
34
45
57
72
91
114
143
182
228
285
360
400
455
515
1007July 2015
Eaton.com/bussmannseries
6-89
Dimensions - mm
Type 1* SKN/ 394
6-90
1007July 2015
Eaton.com/bussmannseries
Time-current curve
Time-current curve
1007July 2015
Eaton.com/bussmannseries
6-91
Indicator systems
Microswitch
Microswitch
170H0235
170H0236
170H0237
170H0238
170H0069
BUL50
Size
000
00
1*
1
2
3
4
23
24
6-92
6.3 x 0.8mm
Lugs
X
X
X
DIN 43 653
Type T
170H0236
170H0238
170H0235
170H0237
170H0235
170H0237
170H0235
170H0237
170H0235
170H0237
170H0235
170H0237
2.8 x 0.5mm
Lugs
X
X
Type K
DIN 43 620
Type T
170H0236
170H0238
170H0069
170H0235
170H0237
170H0069
170H0235
170H0237
170H0236
170H0238
170H0069
170H0069
Indicator
Type
T
T
T
T
K
Type K
Amps
2
2
2
2
2
6
French Style
Type T
170H0236
170H0238
170H0236
170H0238
170H0236
170H0238
170H0236
170H0238
Flush End
Type T
Type K
170H0069
170H0235
170H0237
Type K
US Style
Type K
170H0069
170H0069
170H0069
170H0069
170H0069
170H0069
170H0069
170H0069
170H0069
1007July 2015
170H0069
170H0069
170H0069
170H0069
Eaton.com/bussmannseries
170H0069
170H3004
Catalog
number
170H3003
170H3004
170H3005
170H3006
Max
volts
1000
1000
1400
1400
Amp
rating
630
1250
630
1250
Center
distance
80mm
80mm
110mm
110mm
The fuse bases rated 1250A can also be used for the fuses
with higher rated current if the maximum load current is
derated according to the table below:
Fuse amp
rating
1400
1500
1600
1800
2000
Fixed center
base style
170H1007
170H1013
Max
volts
1000
660
UL Recognized to UL 512.
Max. fuse
amp rating
400
200
Fuse
size
00, 000
0000,000
170H1013
Max. fuse
amp rating
100
400
400
600
100
400
400
700
Data Sheet
1206
1207
1208
1209
1200
1201
1202
1203
High speed
fuses
Modular
base style
1BS101
1BS102
1BS103
1BS104
BH-0xxx
BH-1xxx
BH-2xxx
BH-3xxx
Part number
SD00-D
SD1-D
SD2-D
1007July 2015
Eaton.com/bussmannseries
6-93
British BS 88
Introduction
General information
British BS 88 contents
Fuse
Amp
volts
range
240
6-900
690
6-710
Page
6-95
6-98
Accessories
Indicator system and fuse bases
6-102
Vac
240
690
Vdc
150
500
All Bussmann series British style fuses are tested to IEC 269:
Part 4. This standard requires a test voltage which is 5%
higher than the rated voltage. In North America, fuses are
required to clear only their rated voltage.
Accessories
6-94
1007July 2015
Eaton.com/bussmannseries
British BS 88
Arc voltage
Specifications
Description: BS 88 style
stud-mount fuses.
Dimensions: See dimensions
illustrations.
Ratings:
Volts: 240Vac/150Vdc
Amps: 6-900A
IR: 200kA RMS Sym.
Agency information: CE, Designed and tested to: BS 88
Part 4, IEC 269 Part 4, UL Recognized. All fuses above have
been tested at 318Vac. Consult Eaton for specific UL
Recognition status.
Electrical characteristics
Total clearing I2t
1.0
0.8
0.6
1)
0.4
0.2
50
Catalog numbers
2)
100
150
Eg
200
250
1) LCT
2) LET, LMT, LMMT
7.1
26.2 41.8 56
9.7
17.7
19.1
Fig. 3: LMT
Fig. 4: LMMT
25.4
25.4
31
13.5
59
31 59 84
84
13.5
10.3
10.3
41
83
38.1
Indicator (Optional)
2)
250
100
Power losses
1)
500
1.0
Kp
0.8
200
1) LCT
2) LET, LMT, LMMT
300
Eg
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
70
Ib
80 90 100%
Electrical characteristics
12.7
8.4
UL
38
Catalog
numbers
6LCT
10LCT
12LCT
16LCT
20LCT
25LET
32LET
35LET
50LET
63LET
80LET
100LET
125LET
160LET
180LETa
160LMT
200LMT
250LMT
315LMT
355LMT
400LMT
450LMT
400LMMT
500LMMT
630LMMT
710LMMT
800LMMT
900LMMT
Type
LCT
LET
LMT
LMMT
Rated
current
RMS-amps
6
10
12
16
20
25
32
35
50
63
80
100
125
160
180
160
200
250
315
355
400
450
400
500
630
710
800
900
Pre-arc
2
3.8
7
20
25
18
32
50
100
180
300
600
600
1100
1600
1100
1500
3200
6000
8000
14000
18000
6000
14000
24000
32000
52000
75000
Clearing
at 240V
9
22
32
100
160
250
450
600
1400
2200
3800
7500
7500
16000
29000
16000
20000
40000
75000
100000
160000
220000
80000
170000
300000
460000
600000
800000
Watts
loss
1.0
2.5
2.5
2.5
4.0
4.0
5.0
5.0
7.0
9.0
10.0
10.0
16.0
20.0
21.0
17.0
28.0
28.0
35.0
35.0
40.0
42.0
60.0
64.0
75.0
77.0
82.0
97.0
Typical applications
DC common bus
AC and DC drives
Power converters/rectifiers
Reduced voltage starters
1007July 2015
Eaton.com/bussmannseries
6-95
High speed
fuses
8.7
1.2
28 38 47
6.4
1.4
Fig. 2: LET
Dimensions - mm
Fig. 1: LCT
5.5
1.6
750
British BS 88
Time-current curve
Time-current curve
104
6
4
104
6
4
103
103
6
4
6
4
2
6
4
2
102
101
6
4
2
100
6
4
2
101
6
4
25LET
32LET
35LET
50LET
63LET
100
6
4
2
101
101
6
4
6
4
2
102
102
6
4
6
4
103
103
6
4
6
4
2
104
80LET
100LET
125LET
160LET
180LETa
6
4
6LCT
10LCT
12LCT
16LCT
20LCT
102
2
4
6 8
101
102
Prospective Current In Amps RMS
104
103
101
8 102
900LMMT
800LMMT
710LMMT
630LMMT
450LMT
400 & 500LMMT
355LMT
315LMT
250LMT
6
4
2
104
180LET
200LMT
160LET & LMT
125 & 100LET
80LET
4
2
103
6
4
63LET
50LET
35LET
32LET
25LET
2
10
20LCT
16LCT
12LCT
10LCT
6LCT
6
4
2
101
6-96
101
SYMMETRICAL FAULT
FULLY ASYMMETRICAL FAULT
4
102
103
104
1007July 2015
105
Eaton.com/bussmannseries
8 103
British BS 88
Time-current curve
Time-current curve
104
104
6
4
6
4
2
103
103
6
4
6
4
101
6
4
6
4
2
100
6
4
2
101
6
4
2
101
6
4
2
100
6
4
2
101
6
4
102
6
4
102
6
4
103
103
6
4
6
4
2
2
102
8 103
8 104
104
102
8 103
8 104
900LMMT
800LMMT
710LMMT
630LMMT
450LMT
400 & 500LMMT
355LMT
315LMT
250LMT
6
4
2
10
104
400LMMT
500LMMT
630LMMT
710LMMT
800LMMT
900LMMT
102
2
Virtual Pre-Arcing Time In Seconds
160LMT
200LMT
250LMT
315LMT
355LMT
400LMT
450LMT
102
6
4
180LET
200LMT
160LET & LMT
125 & 100LET
80LET
6
4
2
103
6
4
63LET
50LET
35LET
32LET
25LET
2
102
20LCT
16LCT
12LCT
10LCT
6LCT
6
4
2
101
10
SYMMETRICAL FAULT
FULLY ASYMMETRICAL FAULT
4
102
103
104
105
1007July 2015
Eaton.com/bussmannseries
6-97
British BS 88
Arc voltage
Specifications
Description: BS 88 style
stud-mount fuses.
Dimensions: See dimensions
illustrations.
Ratings:
Volts: 690Vac/500Vdc
Amps: 6-710A
IR: 200kA RMS Sym.
Agency information: CE, Designed and tested to: BS 88
Part 4, IEC 269 Part 4, UL Recognized. MT and MMT
350Vdc (IEC) rating. Consult Eaton for UL Recognition
status.
Electrical
characteristics
1.6
1.4
Dimensions - mm
Fig. 1: CT
5.5
8.7
0.8
0.6
0.2
1)
2)
Eg
200
300
400
500
600 690
7.1
12.7
17.1
600 660
1) CT
2) ET, FE, EET, FEE, FM, FMM
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
Ib
80 90 100%
70
25.4
50
25.4
50
113
14
31.8
37
10.3
10.3
19
41
38.1
1.0
Kp
0.8
Eg
400
13.5
6-98
200
Fig. 4: FM, MT
46 70 94
19.1
500
Typical applications
DC common bus
DC drives
Power converters/rectifiers
Reduced voltage starters
8.7
11.9
2)
48 63.5 77
9.7
8.7
1.0
Fig. 2: ET, FE
6.4
1)
1000
Power losses
1.2
0.4
UL
1500
1007July 2015
Eaton.com/bussmannseries
38
Figs. 4 & 5 A Dimensions
Type
A
FM
80-85mm
FMM
80-85mm
MT
85mm
MMT
85mm
83
113
British BS 88
Catalog numbers
ET
FE
EET
FEE
FM
FMM
MT
MMT
Time-current curve
104
6
4
2
103
6
4
25ET
32ET
35ET
40ET
45ET
56ET
63ET
80ET
2
102
6
4
Virtual Pre-Arcing Time In Seconds
CT
Watts
loss
2
3
3
7
7
7
11
11
9
11
14
16
18
9
9
11
11
12
17
20
20
23
19
27
35
39
24
32
36
46
46
52
40
40
44
48
48
55
55
85
90
100
100
100
120
26
26
27
32
35
42
51
42
42
42
47
51
54
60
57
64
64
86
105
2
101
6
4
6CT
10CT
12CT
16CT
20CT
2
100
6
4
2
101
6
4
2
102
6
4
2
103
6
4
2
104
8 101
8 102
8 103
315MT 355MT
280MT
250MT
105
180MT
160MT
4
2
710MMT
630MMT
560MMT
500MMT
450MMT
400MMT
355MMT
315MMT
280MMT
200MT
225MMT
200MMT
180MMT
104
Type
High speed
fuses
Catalog
numbers
6CT
10CT
12CT
16CT
20CT
25ET
32ET
35ET
40ET
45ET
56ET
63ET
80ET
35FE
40FE
45FE
50FE
63FE
71FE
80FE
90FE
100FE
90EET
110EET
140EET
160EET
100FEE
120FEE
140FEE
160FEE
180FEE
200FEE
180FM
200FM
225FM
250FM
280FM
315FM
350FM
400FMM
450FMM
500FMM
550FMM
630FMM
700FMM
160MT
180MT
200MT
250MT
280MT
315MT
355MT
180MMT
200MMT
225MMT
280MMT
315MMT
355MMT
400MMT
450MMT
500MMT
560MMT
630MMT
710MMT
Electrical characteristics
Rated
I2t (A2 sec)
current
Clearing Clearing
RMS-amps Pre-arc
at 415V
at 660V
6
1.8
8.5
12
10
7
30
48
12
10
40
65
16
16
66
110
20
32
150
220
25
25
150
250
32
32
190
350
35
52
310
500
40
103
600
900
45
103
680
1100
56
135
950
1500
63
171
1200
2000
80
360
2500
4000
35
33
130
200
40
52
180
300
45
76
270
450
50
103
380
600
63
135
480
750
71
210
600
950
80
250
900
1500
90
360
1300
2100
100
470
1800
2800
90
490
3000
4500
110
600
4000
6500
140
1050
7000
12000
160
1500
10000
17000
100
400
1600
2400
120
540
1900
3100
140
850
2500
3800
160
1000
3700
5700
180
1400
5300
8400
200
1900
7100
11400
180
1400
7500
13500
200
2600
10500
18500
225
3700
14500
26500
37500
250
5200
20500
280
7000
30500
55000
315
10000
40000
77000
350
15000
60000
105000
400
10000
40000
72500
450
15000
60000
105000
500
20000
82000
150000
550
30000
120000
215000
630
45000
180000
310000
700
60000
245000
420000
160
2400
15000
25000
180
3800
25000
38000
200
6000
40000
58000
250
11500
80000
110000
280
16500
100000
150000
180000
315
19000
125000
355
22000
160000
200000
180
1650
12000
18000
200
2200
16000
23000
225
3700
26000
40000
280
6600
47000
70000
315
8600
62000
91000
355
13500
97000
140000
400
21000
150000
220000
450
30000
220000
320000
500
42000
300000
450000
560
60000
430000
640000
630
68500
500000
720000
710
78000
600000
850000
6
4
2
103
6
4
2
20CT
16CT
12CT
10CT
6CT
102
6
4
160EET
140EET
110EET
90EET
80ET
63ET
56ET
45ET
40ET
35ET
32ET
25ET
101
101
102
103
104
105
1007July 2015
Eaton.com/bussmannseries
6-99
British BS 88
Time-current curve
104
Time-current curve
104
6
4
2
103
6
4
2
101
6
4
90EET
110EET
140EET
160EET
2
100
6
4
2
10
6
4
180MMT
200MMT
225MMT
280MMT
315MMT
355MMT
6
4
2
100
6
4
2
101
102
6
4
6
4
6
4
2
103
2
104
6
4
6
4
2
103
6
4
2
101
2
102
400MMT
450MMT
500MMT
560MMT
630MMT
710MMT
2
102
103
160MT
180MT
200MT
250MT
280MT
315MT
355MT
6
4
2
102
6
4
8 102
8 103
8 104
6
4
2
104
102
4
6 8
2
4
103
Prospective Current In Amps RMS
315MT 355MT
280MT
250MT
105
180MT
160MT
4
2
710MMT
630MMT
560MMT
500MMT
450MMT
400MMT
355MMT
315MMT
280MMT
200MT
225MMT
200MMT
180MMT
104
6
4
2
103
6
4
2
20CT
16CT
12CT
10CT
6CT
102
6
4
160EET
140EET
110EET
90EET
80ET
63ET
56ET
45ET
40ET
35ET
32ET
25ET
101
6-100
101
102
103
104
1007July 2015
105
Eaton.com/bussmannseries
104
British BS 88
Time-current curve
103
Time-current curve
104
6
4
6
4
2
6
4
103
6
4
180FM
200FM
220FM
250FM
280FM
315FM
350FM
102
6
4
2
101
6
4
2
35FE
40FE
45FE
50FE
63FE
71FE
80FE
90FE
100FE
100
6
4
2
101
6
4
2
102
6
4
2
101
6 100FEE
4 120FEE
140FEE
2 160FEE
180FEE
100 200FEE
6
4
2
101
6
4
2
102
6
4
103
6
4
2
104
400FMM
450FMM
500FMM
550FMM
630FMM
700FMM
102
6
4
Virtual Pre-Arcing Time In Seconds
104
8 102
8 103
8 104
103
6
4
2
104
102
2
103
6
4
2
100FE
90FE
80FE
71FE
63FE
50FE
45FE
40FE
35FE
102
6
4
2
101
102
103
104
450FMM
400FMM
104
8
6
4
103
200FEE
105
180FEE
160FEE
140FEE
500FMM
550FMM
350FM
315FM
280FM
250FM
225FM
200FM
180FM
High speed
fuses
104
630FMM
104
700FMM
6
2
105
101
4
6 8
2
4
103
Prospective Current In Amps RMS
120FEE
100FEE
102
103
104
105
1007July 2015
Eaton.com/bussmannseries
6-101
Indicator system
Trip-indicators
Trip-indicator
Dimensions - mm
TI500
500
700
130
0.3
1.5A
100,000
23
46
TI700
700
1000
350
0.45
1.5A
100,000
23
46
Details
Fuse mount
Indicator kits
(Includes one
indicator
and two clips)
B
21
C
6
Ref.
TI250
TI500
TI600
TI700
TI1100
TI1500
TI2000
TI2500
Dim. A (mm)
37.6
47.5
55.7
61.8
98.4
120.6
147.5
198.3
For use
with fuse ref.
LET
LMT and LMMT
FE, FEE and ET
FM and FMM
MT and MMT
50.8
NO
NC
NC
NO
Dimensions - in mm
6-102
6.0
Terminal arrangement
4A
6A
0.7A DC
2A DC
1000V
1500V
110Vdc
1007July 2015
Eaton.com/bussmannseries
6.35
6.8
RMS volts
250
500
600
700
1100
1500
2000
2500
14
RMS
volts
250
250
660
660
700
E
0.8
Electrical specifications
Type
Maximum RMS voltage
Maximum peak voltage
Maximum DC voltage
Cold resistance (ohms)
Maximum permissible steady-state current
Interrupting capacity (RMS Symm.)
Pre-Arcing I2t
Total I2t (max volts)
Trip
indicator
8.7
Ferrule
Table of contents
Basic catalog
Number
FWA
FWX
FWH
FWC
FWP
FWK
FWJ
FWL/FWS
Volts
150
250
500
600
690V/700
750
1000
1250/1500/2000
Amp
range
5-60
1-50
0.25-30
6-32
1-100
5-60
20-30
2-30
Accessories
Fuse holders
Page
6-104
6-106
6-108
6-112
6-114
6-118
6-120
6-122
6-123
Amps
5-60
1-50
0.25-30
6-32
20-100
1-50
5-60
20-30
20-30
8-15
2-6
AC
X
X
X
X
X
X
X
X
X
X
X
DC
X
X
X
X
X
X
X (800Vdc)
X (1000Vdc)
X (1000Vdc)
X (1000Vdc)
Eaton offers a full line of ferrule style (cylindrical clipmounted) fuses, designed and tested to meet standards and
requirements in various locations around the world. Their
unique design and construction provide:
Superior cycling capability
Low energy let-through (I2t)
Ferrule fuses provide an excellent solution for small UPS,
small AC drives and other low power applications where
space is at a premium.
Voltage rating
1007July 2015
Eaton.com/bussmannseries
6-103
High speed
fuses
Volts
150
250
500
600
700 (22 x 58mm)
700 (14 x 51mm)
750
1000
1250
1500
2000
General information
Ferrule
Arc voltage
Specifications
Description: Ferrule style high
speed fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 150Vac/dc
Amps: 5-60A
IR: 100kA Sym.
Agency information: CE, ULRecognized JFHR2.E91958.
Electrical
characteristics
Total clearing I2t
1.5
1.0
0.3
0.2
0.15
2)
22
Dimensions
A
B
1.5 (38.1)
0.375 (9.5)
2.0 (50.8)
0.625 (15.9)
70
Eg
102
1) 5-30A Range
2) 35-60A Range
150
50
100
150
0.6
0.5
0.4
0.3
0.2
0.1
Size
10 x 38mm
(1332 x 112)
21 x 51mm
(1316 x 2)
Fuse block
BMM603xB
No block
J70032-xCR*
No block
J70032-xCR*
J70032-xCR*
J70100-xCR*
No block
No block
No block
30 40 50
60
70
Typical applications
DC common bus
DC drives
Power converters/rectifiers
Reduced voltage starters
Pre-arc
1.6
3.6
14
33
58
100
75
100
130
170
250
Ib
80 90 100%
Clearing
at 150V
8
16
55
130
220
400
800
1000
1300
1600
2400
Rated
current
RMS-amps
5
10
15
20
25
30
35
40
45
50
60
6-104
1.0
Kp
0.8
Eg
Electrical characteristics
I2t (A2 sec)
Catalog
numbers
FWA-5A10F
FWA-10A10F
FWA-15A10F
FWA-20A10F
FWA-25A10F
FWA-30A10F
FWA-35A21F
FWA-40A21F
FWA-45A21F
FWA-50A21F
FWA-60A21F
C
0.406 (10.3)
0.811 (20.6)
Catalog
number
FWA 5-30A10F
FWA 35-60A21F
FWX 1-50A14F
FWH 0.250-030A6F
FWH 1-30A14F
FWP 1-50A14F
FWP 20-100A22F
FWJ 30-30A14F
FWS 2-15A20F
FWL 20-30A20F
100
Catalog numbers
Dimensions - in (mm)
Amp
range
5-30
35-60
200
1)
0.5
300
Power losses
UL
Eaton.com/bussmannseries
Watts
loss
1
2.7
3.3
3.8
4.9
4.9
4.5
5.1
6
7.3
8.0
Ferrule
Time-current curve
103
102
Time-current curve
104
6
4
6
4
2
6
4
103
6
4
6
4
102
6
4
Virtual Pre-Arcing Time In Seconds
104
2
101
FWA-5A10F
FWA-10A10F
FWA-15A10F
FWA-20A10F
FWA-25A10F
FWA-30A10F
6
4
2
100
6
4
2
101
102
103
2
100
6
4
2
6
4
102
6
4
6
4
103
6
4
2
2
2
101
102
104
103
101
102
FWA-30A10F
FWA-25A10F
FWA-20A10F
FWA-15A10F
6
4
2
FWA-12A10F
FWA-10A10F
FWA-5A10F
102
10
6
4
2
102
101
103
101
FWA-60A21F
FWA-50A21F
FWA-45A21F
FWA-40A21F
FWA-35A21F
High speed
fuses
104
103
104
2
101
6
4
101
6
4
6
4
104
FWA-35A21F
FWA-40A21F
FWA-45A21F
FWA-50A21F
FWA-60A21F
2
2
102
103
104
105
101
101
102
103
104
105
1007July 2015
Eaton.com/bussmannseries
6-105
Ferrule - UL
Specifications
Description: Ferrule style high
speed fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 250Vac/dc
Amps: 1-50A
IR: 200kA RMS Sym.
50kA @ 250Vdc
Agency information: CE, UL Recognized JFHR2.E91958
1-50A and CSA Component Acceptance file Class 1422-30,
1422-90 (53787) 5-30A.
1.5
Electrical
characteristics
2
Total clearing I t
1.0
0.5
0.3
0.2
0.15
2)
125
200
Eg
250
300
14.3
(0.563")
15.5
(0.610")
Catalog
number
FWX-1A14F
FWX-2A14F
FWX-3A14F
FWX-4A14F
FWX-5A14F
FWX-10A14F
FWX-15A14F
FWX-20A14F
FWX-25A14F
FWX-30A14F
FWX-50A14F
400
1)
300
200
50
1.0
Kp
0.8
100
2)
150
200
Eg
250
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
70
Ib
80 90 100%
Size
14 x 51mm
(916 x 2)
Typical applications
DC common bus
DC drives
Power converters/rectifiers
Reduced voltage starters
Electrical characteristics
Rated
I2t (A2sec)
current
Clearing
RMS-amps
Pre-arc
at 250V
1
5
1.6
13
10
3.6
24
15
14
83
20
33
200
25
58
300
30
100
500
50
200
1800
Watts
loss
1.3
3.4
3.8
4.6
5.3
5.9
5.7
6-106
600
500
Catalog numbers
Dimensions - mm (in)
50.8
(2.000")
800
1)
UL
103
Power losses
75
1.4
1.2
Arc voltage
1007July 2015
Eaton.com/bussmannseries
Time-current curve
High speed
fuses
1007July 2015
Eaton.com/bussmannseries
6-107
Ferrule
Agency information
Catalog symbols:
FWH-(amp)A6F
FWH5-(amp)A6F
CE
RoHS compliant
Description:
Eatons Bussmann series of FWH 6x32mm ferrule high speed
fuses are for the protection of DC common bus, DC drives, power
converters/rectifiers and reduced rated voltage starters.
Ratings
Features:
Volts
1000Vac (2A)
600Vdc (1-5A)
Dimensions:
31.8
(1.25)
Amps
6.4
(0.25)
0.25-30A
Interrupting rating
30kA AC (2A)
20kA AC (25-30A)
50kA DC (1-5A)
3.2
(0.125)
Typical applications:
Opening times:
Amp range
150%
200%
300%
0.25-7A
> 30 min.
> 30 min.
10 sec.
10-30A
> 30 min.
> 30 min.
10 sec.
DC common bus
DC drives
Power converters/rectifiers
Catalog numbers:
I2t (A2s)
Rated voltage
Catalog numbers
Amps
Vac
Vdc
Pre-arcing
Clearing @ 500Vac
Standard
RoHS compliant
0.25
500
0.01
0.05
2.7
FWH-250A6F
FWH-250A6FR
0.5
500
0.05
0.25
1.2
FWH-500A6F
FWH-500A6FR
500
600
0.4
1.7
FWH-001A6F
FWH-001A6FR
1000
600
1.3
3.5
3.2
FWH-002A6F
FWH-002A6FR
3.15
500
600
3.1
7.7
2.9
FWH-3.15A6F
FWH-3.15A6FR
500
600
FWH-004A6F
FWH-004A6FR
500
600
15
40
2.1
FWH-005A6F
FWH-005A6FR
6.3
500
36
90
2.3
FWH-6.30A6F
FWH-6.30A6FR
500
50
125
2.5
FWH-007A6F
FWH-007A6FR
10
500
9.9
139
2.86
FWH5-010A6F
FWH5-010A6FR
12.5
500
20
60
3.53
FWH5-12-5A6F
FWH5-12-5A6FR
15
500
44
146
3.08
FWH5-015A6F
FWH5-015A6FR
16
500
48
177
4.48
FWH5-016A6F
FWH5-016A6FR
20
500
75
259
4.26
FWH5-020A6F
FWH5-020A6FR
25
500
126
345
FWH-025A6F
FWH-025A6FR
30
500
145
430
FWH-030A6F
FWH-030A6FR
1007July 2015
Eaton.com/bussmannseries
Time-current curve
Time-current curve
104
6
4
FWH-002A6F
FWH-3.15A6F
FWH-005A6F
103
FWH-6.30A6F
FWH-007A6F
6
4
2
102
6
4
2
101
6
4
2
100
6
4
2
101
6 FWH-.250A6F
4 FWH-.500A6F
FWH-001A6F
2
102
4x103
.2
.4
.6
.8
100
101
102
High speed
fuses
1007July 2015
Eaton.com/bussmannseries
6-109
Ferrule
Arc voltage
Specifications
Description: Ferrule style high
speed fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 500Vac
Amps: 1-30A
IR: 200kA RMS Sym.
50kA @500Vdc
Agency information: CE, UL Recognized 1-30A and CSA
Component Acceptance file Class 1422-30, (53787) on:
5 - 30A.
Power losses
Electrical characteristics
Total clearing I2t
1.5
1.0
Catalog numbers
0.5
0.3
0.2
0.15
100
250
400
Dimensions - mm (inches)
50.8
(2.000")
14.3
(0.563")
15.5
(0.610")
Catalog
numbers
Size
FWH-1A14F
14 x 51mm
9
FWH-2A14F
( 16 x 2)
FWH-3A14F
FWH-4A14F
FWH-5A14F
FWH-6A14F
FWH-10A14F
FWH-12A14F
FWH-15A14F
FWH-20A14F
FWH-25A14F
FWH-30A14F
Eg
500
UL
1.6
1.2
103
800
600
500
400
300
100
1.0
Kp
0.8
200
300
1007July 2015
0.3
0.2
0.1
30 40 50
60
70
Ib
80 90 100%
Electrical characteristics
Rated
I2t (A2 sec)
current
Clearing
RMS-amps
Pre-arc
at 500V
1
5
1.6
6.4
6
1.6
6.4
10
3.6
13
12
15
10
40
20
26
96
25
49
191
30
58
232
Typical applications
DC common bus
DC drives
Power converters/rectifiers
Reduced voltage starters
500
0.4
Eaton.com/bussmannseries
400
Eg
0.6
0.5
6-110
2.0
Watts
loss
2.3
1.5
1.5
4
5.5
6
7
9
10
FWH-5A14F
FWH-10A14F
FWH-15A14F
FWH-20A14F
FWH-25A14F
FWH-30A14F
6
4
2
101
6
4
2
100
6
4
2
10
6
4
2
102
6
4
2
103
6
4
2
10
101
102
103
High speed
fuses
6
4
2
FWH-30A14F
FWH-25A14F
103
10
6
4
2
FWH-20A14F
FWH-15A14F
FWH-10A14F
FWH-5A14F
6
4
2
10
101
102
103
104
105
1007July 2015
Eaton.com/bussmannseries
6-111
Ferrule
Arc voltage
Specifications
Description: Ferrule style high
speed fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 600Vac/700Vdc (6-25A)
600Vac (30-32A)
Amps: 6-32A
IR: 200kA RMS Sym.
50kA @ 700Vdc (6-25A)
Agency information: CE, UL Recognized JFHR8.E91958
6-32A and CSA Component Acceptance file Class 1422-30,
(53787) on (6-32A).
Electrical characteristics
2
Total clearing I t
1.5
1.0
Power losses
0.5
Dimensions - mm (in)
38.1
(1.500")
250
400
10.3
(0.406")
9.5
(0.375")
Eg
500
Catalog
numbers
Size
FWC-2A10F
FWC-3A10F
FWC-4A10F
FWC-6A10F
FWC-8A10F
FWC-10A10F
FWC-12A10F 10 x 38mm
FWC-16A10F (1332 x 112)
FWC-20A10F
FWC-25A10F
FWC-30A10F
FWC-32A10F
600
UL
1.2
103
800
600
500
400
300
200
1.0
Kp
0.8
Eg
300
400
500
600
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
70
Ib
80 90 100%
Typical applications
DC Common bus
DC Drives
Power converters/rectifiers
Reduced voltage starters
Electrical characteristics
Rated
I2t (A2 sec)
current
Clearing
RMS-amps
Pre-arc
at 600V
2
0.5
3
3
1.6
11
4
5.2
32
6
4
30
8
6
50
10
9
70
12
15
120
16
25
150
20
34
260
25
60
390
600
30
95
32
95
600
6-112
1.6
Catalog numbers
0.3
0.2
0.15
100
2.0
1007July 2015
Eaton.com/bussmannseries
Watts
loss
1.2
1.5
1.5
1.5
2.0
2.5
3.0
3.5
4.8
6.0
7.5
7.5
6
4
2
103
FWC-6A10F
FWC-8A10F
FWC-10A10F
FWC-12A10F
FWC-16A10F
FWC-20A10F
FWC-25A10F
FWC-30A10F & FWC-32A10F
6
4
2
102
6
4
2
101
6
4
2
100
6
4
2
101
6
4
2
102
6
4
2
103
6
4
2
10
101
8 102
8 103
High speed
fuses
4
2
103
10
6
4
2
FWC-12A10F
FWC-10A10F
FWC-8A10F
FWC-6A10F
6
4
2
10
101
102
103
104
105
1007July 2015
Eaton.com/bussmannseries
6-113
Ferrule
FWP 690V/700V:
1-50A (14 x 51mm)
striker optional
Arc voltage
Specifications
Description: Ferrule style high
speed fuses with and without
indicating striker.
Dimensions: See dimensions
illustrations.
Ratings:
FWP with
Volts: 690Vac (IEC)
striker option.
700Vac (UL)
800Vdc (5-50A)
Amps: 1-50A
IR: 200kA RMS Sym.
50kA @800Vdc
Agency information: CE, UL Recognized JFHR2.E91958,
CSA Component Acceptance file Class 1422-30, 1422-90
(53787) for versions with1.4
out indicator only.
1.2
K
Designed and
1.0
tested to IEC 60269:
0.9
Part 4.
0.8
0.7
0.6
Electrical
characteristics
0.5
2
Total clearing I t
0.4
1)
2)
Power losses
Catalog
numbers
Without striker
FWP-1A14F
FWP-2A14F
FWP-2.5A14F
FWP-3A14F
FWP-4A14F
FWP-5A14F
FWP-10A14F
FWP-15A14F
FWP-20A14F
FWP-25A14F
FWP-30A14F
FWP-32A14F
FWP-40A14F
FWP-50A14F
With striker*
FWP-10A14FI
FWP-15A14FI
FWP-20A14FI
FWP-25A14FI
FWP-30A14FI
FWP-32A14FI
FWP-40A14FI
FWP-50A14FI
Dimensions - mm (in)
Without striker
14.3
(0.563")
Size
With Striker
59 (2.323")
51 (2.00")
13 (0.511")
14 x 51mm
(916" x 2")
14 x 51mm
(916 x 2)
4
200
1.0
Kp
0.8
300
400
500
600
Eg
700
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
70
Ib
80 90 100%
1007July 2015
1
2
2.5
3
4
5
10
15
20
25
30
32
40
50
10
15
20
25
30
32
40
50
Electrical characteristics
Rated
I2t (A2 sec)
Minimum
Clearing at
melting
rated voltage
1.6
3.6
8.6
26.0
46.5
58
68
84
200
3.6
8.6
26.0
46.5
58
68
84
200
11.0
38.5
70
230
375
485
600
750
1800
38.5
70
230
375
485
600
750
1800
5 (0.197")
6-114
Current
RMS-amps
15.5
(0.610")
UL
Catalog numbers
14.3
(0.563")
1.4
1.2
103
9
8
7
6
g
The total clearing I2t at
0.3
200 300
400
500 600 700
rated voltage and at power
1) 5-30A Range
factor of 15% are given in
2) 32-50A Range
the electrical
characteristics. For other voltages, the clearing I2t is found by
multiplying by correction factor, K, given as a function of
applied working voltage, Eg, (rms).
50.8
(2.000")
Eaton.com/bussmannseries
Watts
loss
1.5
4
5.5
6
7
9
7.6
8
9
4
5.5
6
7
9
7.6
8
9
Without striker
FWP 5-50A: 660V/700V (14 x 51mm)
Time-current curve
104
6
4
2
103
6
4
2
102
FWP-25A14F
FWP-30A14F
FWP-32A14F
FWP-40A14F
FWP-50A14F
6
4
2
101
6
4
2
100
101
6
4
FWP-5A14F
FWP-10A14F
FWP-15A14F
FWP-20A14F
2
6
4
2
102
6
4
2
103
6
4
2
104
101
102
103
High speed
fuses
FWP-50A14F
FWP-40A14F
FWP-32A14F
FWP-30A14F
FWP-25A14F
6
4
2
103
6
4
2
FWP-20A14F
FWP-15A14F
FWP-10A14F
FWP-5A14F
102
6
4
2
101
101
102
103
104
105
1007July 2015
Eaton.com/bussmannseries
6-115
Ferrule - IEC/UL
FWP 690V/700V:
20-100A (22 x 58mm)
striker optional
Specifications
Description: Ferrule style high
speed fuses with and without
indicating striker.
Dimensions: See dimensions
illustration.
Ratings:
FWP with
striker
Volts: 690Vac (IEC)
option.
700Vac (UL)
500Vdc (20-100A)
Amps: 20-100A
IR: 200kA RMS Sym.
50kA @ 500Vdc
Agency information: CE, UL Recognized JFHR2.E91958,
CSA Component Acceptance file Class 1422-30, 1422-90
(53787).
1.4
1.2
1.0
0.9
0.8
0.7
0.6
Electrical
characteristics
Total clearing I2t
Power losses
Catalog
numbers
Without striker
FWP-20A22F
FWP-25A22F
FWP-32A22F
FWP-40A22F
FWP-50A22F
FWP-63A22F
FWP-80A22F
FWP-100A22F
With striker
FWP-20A22FI
FWP-25A22FI
FWP-32A22FI
FWP-40A22FI
FWP-50A22FI
FWP-63A22FI
FWP-80A22FI
FWP-100A22FI
0.4
300
400
500
600
Eg
700
Dimensions - mm (in)
Without striker
58.0
(2.283")
22.2
(0.875")
15.0
(0.591")
With striker
66 (2.598")
58 (2.283")
5
(0.197")
16 (0.630"
Size
22 x 58mm
(78" x 2932")
22 x 58mm
(78" x 2932")
5
4
200
1.0
Kp
0.8
300
400
500
600
Eg
700
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
70
1007July 2015
20
25
32
40
50
63
80
100*
20
25
32
40
50
63
80
100*
Typical applications
DC common bus
DC drives
Power converters/rectifiers
Reduced voltage starters
Rated
current
RMS-amps
Ib
80 90 100%
Electrical characteristics
I2t (A2 sec)
Minimum
Clearing at
melting
rated voltage
Watts
loss
19.0
34.0
53.5
68
135
280
600
1100
5
6
8
9
9.5
11
13.5
16
19.0
34.0
53.5
68
135
280
600
1100
260
410
605
750
1600
3080
6600
12500
260
410
605
750
1600
3080
6600
12500
22.2 (0.874")
6-116
UL
Catalog numbers
0.5
0.3
200
1.4
1.2
103
9
8
7
6
Arc voltage
Eaton.com/bussmannseries
5
6
8
9
9.5
11
13.5
16
Without striker
FWP 20-100A: 660V/700V (22 x 58mm)
Time-current curve
104
6
4
2
103
6
4
2
102
FWP-50A22F
FWP-63A22F
FWP-80A22F
FWP-100A22F
6
4
2
101
6
4
2
10
6
4
FWP-20A22F
FWP-25A22F
FWP-32A22F
FWP-40A22F
2
101
6
4
2
102
6
4
2
103
6
4
2
104
101
102
103
104
FWP-100A22F
FWP-80A22F
FWP-63A22F
High speed
fuses
FWP-50A22F
2
103
6
FWP-40A22F
FWP-32A22F
FWP-25A22F
FWP-20A22F
2
102
102
103
104
105
1007July 2015
Eaton.com/bussmannseries
6-117
Ferrule
Typical applications
DC common bus
DC drives
Power converters/rectifiers
Reduced voltage starters
Catalog numbers
Catalog
numbers
FWK-5A20F
FWK-8A20F
FWK-10A20F
FWK-15A20F
FWK-20A20F
FWK-25A20F
FWK-30A20F
FWK-35A25F
FWK-40A25F
FWK-50A25F
FWK-60A25F
Size
20 x 127mm
(1316 x 5)
25 x 146mm
(1 x 534)
Electrical characteristics
Rated
I2t (A2 sec)
current
Clearing
RMS-amps
Pre-arc
at 750Vdc
5
8.5
16
8
50
100
95
200
10
15
100
240
20
125
315
25
400
1100
30
800
2600
35
1300
4300
40
1600
5300
50
3100
12000
60
5900
24000
Dimensions - mm (in)
Fig. 1: 5-30A
127.0
(5.000")
20.5
(0.807")
16.0
(0.630")
Fig. 2: 35-60A
146.05
(5.75")
25.4
(1")
20.64
(0.813")
1007July 2015
Eaton.com/bussmannseries
FWK-20A20F
103
FWK-25A20F
FWK-30A20F
FWK-40A25F
FWK-50A25F
FWK-60A25F
102
Virtual Pre-Arcing Time In Seconds
6
4
2
101
6
4
2
10
6
4
FWK-5A20F
FWK-8A20F
2
10
FWK-10A20F
6
4
2
10
4x10
101
102
103
High speed
fuses
1007July 2015
Eaton.com/bussmannseries
6-119
Ferrule
Arc voltage
Specifications
Description: Ferrule style high
speed fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 1000Vac/800Vdc
Amps: 20-30A
IR: 25kA RMS Sym.
20kA @ 800Vdc
Agency information: CE, UL Recognized JFHR2.E91958
1.5
Electrical
characteristics
1.0
0.15
200
500
800
Dimensions - mm (in)
66.7
(2.626")
1000
Catalog
numbers
FWJ-20A14F
FWJ-25A14F
FWJ-30A14F
Size
14 x 67mm
9
( 16 x 258)
200
1.0
Kp
0.8
600
Eg
0.6
0.5
0.4
0.3
0.2
0.1
30 40 50
60
70
Ib
80 90 100%
Typical applications
DC common bus
DC drives
Power converters/rectifiers
Reduced voltage starters
1007July 2015
Electrical characteristics
I2t (A2 sec)
Clearing
Pre-arc
at 1000V
25
220
33
350
52
450
Fuseclips:
Catalog number: 5591 (see data sheet 2132)
400
Rated
current
RMS-amps
20
25
30
14.5
(0.571")
800
Catalog numbers
Eg
15.9
(0.625")
6-120
1200
0.5
UL
1600
Power losses
0.3
0.2
2000
Eaton.com/bussmannseries
Watts
loss
9
11
14
6
4
2
103
6
4
2
102
6
4
2
10
6
4
FWJ-20A14F
FWJ-25A14F
FWJ-30A14F
2
100
6
4
2
10
10
10
10
6
4
2
6
4
2
6
4
2
101
8 102
8 103
High speed
fuses
FWJ-30A14F
FWJ-25A14F
FWJ-20A14F
103
102
2
10
101
102
103
104
105
1007July 2015
Eaton.com/bussmannseries
6-121
Ferrule
Typical applications
DC Common bus
DC Drives
Power converters/rectifiers
Reduced voltage starters
Traction aux circuits
Capacitor protection
Time-current curve
Catalog numbers
Catalog
numbers
FWS-2A20F
FWS-6A20F
FWS-8A20F
FWS-10A20F
FWS-12A20F
FWS-15A20F
FWL-20A20F
FWL-25A20F
FWL-30A20F
Size
20 x 127mm
(1316 x 5)
20 x 127mm
(1316 x 5)
Electrical characteristics
Rated
I2t (A2 sec)
current
Clearing
Pre-arc
at 1000Vdc
RMS-amps
2
0.8
2.4
6
27
81
8
64
192
10
118
277
12
170
380
15
209
500
20
675
1550
25
1200
2760
30
1850
4300
Dimensions - mm (in)
127.0
(5.000")
Watts
loss
4.4
6.7
7.6
3.0
3.4
5.0
5.9
6.5
7.5
20.5
(0.807")
16.0
(0.630")
20.5
(0.807")
2.0
16.0
(0.630")
2.0
(0.079")
6-122
1007July 2015
Eaton.com/bussmannseries
Fuse blocks
Fuse holders
Specifications
Catalog Symbol: CH
Description: DIN-Rail mount
fuse holders
Agency information:
UL File E14853, Guide IZLT
Listed, IZLT2 Recognized
CSA: File 47235, CHPV and
CHM - Class 6225-30,
CHCC - Class 6225-01
Ratings: 600V/30A (UL)
690V/32A (IEC)
Features and benefits
Finger-safe design - No exposed contacts
DIN-Rail mount (35mm) - Fits standard mounting rails
Optional open fuse indication lights tells fuse status at a
glance
Handle/fusepuller easily installs and removes fuses
Available in single and multi-pole configurations
Wire ready lugs and spade terminal connections save
installation time
CE marking
Available up to 1000Vdc
PLC device available for remote monitoring
Specifications
Catalog symbol: J70032,
J70100
Description: Fuse blocks
for 22x58mm and 14x51mm
fuses.
Ratings:
Volts: 700Vac/dc
Amps: 32-100A
Withstand: 200kA RMS Sym.
Agency information: CE, UL Recognized, Guide IZLT2,
File E14853
Flammability rating: UL 94V0
Catalog numbers
Catalog
numbers
Fuse
size
J70032-2CR
14x51
J70032-1CR
J70032-3CR
JM70100-1CR
22x58
JM70100-2CR 22x58
JM70100-3CR
32
Poles
Max wire
size
100
#2
Amps
32
32
100
100
1
3
2
3
#2
#2
#2
#2
Terminations
Box Lug w/
BoxClip
lug w/
Retaining
retaining clip
#2
Typical applications
Switchboard panel, control consoles, small motors,
transformers, and similar applications
High speed
fuses
1007July 2015
Eaton.com/bussmannseries
6-123
Faster lead-time.
Better protection.
More energy efficient.
6-124
1007July 2015
Eaton.com/bussmannseries
Application data
Contents
Description
Page
CAMaster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-20
SAFEloc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-20
Red Spot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-20
The current rating of the fuse should not be less than the full
load current of the circuit. The circuit should be so designed
that small overloads of long duration will not be of frequent
occurrence.
Cable ratings and protection
1007July 2015
Eaton.com/bussmannseries
7-1
7
Cable size (mm2)
1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
Capacitor circuits
Ambient temperature
7-2
kW
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22.0
30.0
37.0
45.0
55.0
75.0
90.0
110.0
132.0
150.0
185.0
200.0
225.0
250.0
280.0
335.0
355.0
1007July 2015
Rating motor
A
0.8
1.1
1.5
2.0
30
3.6
5.0
6.5
8.4
11.0
15.0
20.0
27.0
33.0
38.0
54.0
66.0
79.0
98.0
135.0
155.0
185.0
220.0
250.0
310.0
335.0
375.0
415.0
460.0
562.0
596.0
Eaton.com/bussmannseries
Direct on-line
Standard
Motor circuit
(gG)
(gM)
A
A
4
4
6
6
10
16
16
20
20
25
20M25
40
32M40
50
32M50
63
32M63
80
63M80
80
63M80
100
63M100
125
100M125
160
100M160
160
100M160
250
200M250
250
200M250
315
200M315
355
315M400
355
315M400
450
400M500
500
400M500
560
560
630
710
800
-
Asst. start
standard
(gG)
A
2
2
4
4
6
01
01
61
61
2 20
25
32
40
50
50
80
80
100
100
160
160
200
250
315
355
400
400
450
500
630
710
Typical applications
Lighting, heating and other circuits not subject to temporary
surges and where available short-circuit current are
relatively low.
Basic catalog numbers
Time-Delay CSA Type D fuses
Catalog
numbers
Volts
CDN*
250Vac
CDS**
600Vac
Amp
ratings
10, 12, 15, 20, 25, 30, 35, 40, 45, 50, 60,
70, 80, 90, 100, 110, 125, 150, 175, 200,
225, 250, 300, 350, 400, 450, 500, 600
10, 12, 15, 20, 25, 30, 35, 40, 45, 50, 60,
70, 80, 90, 100, 110, 125, 150,175, 200,
225, 250, 300, 350, 400, 450, 500, 600
Volts
250Vac
Dimensions - in (mm)
CDN/PON 250Vac
CDS 600Vac
Ferrule: 1 to 60A
C
A
D
Knifeblade: 70 to 600A
A
Overall
2.0 (50.8)
3.0 (76.2)
5.88 (149.4)
7.3 (185.4)
8.63 (219.2)
10.38 (263.7)
5.0 (127.0)
5.5 (139.7)
7.88 (200.2)
9.63 (244.6)
11.63 (295.4)
13.38 (339.9)
B Max
Diameter
0.56 (14.3)
0.81 (20.6)
0.81 (20.6)
1.06 (27.0)
2-pole
Fuse
250V
600V
250V
600V
1-30A
HM25030-1 HM60030-1 HM25030-2 HM60030-2
35-60A
HM25060-1 HM60060-1 HM25060-2 HM60060-2
70-100
HM25100-1 HM60100-1 HM25100-2 HM60100-2
110-200
HM25200-1 HM60200-1 HM25200-2 HM60200-2
225-400
HM25400-1 HM60400-1 HM25400-2 HM60400-2
450-600
HM25600-1 HM60600-1 HM25600-2 HM60600-2
See data sheets 100289 (30-60A) and 3192 (70-600A) for terminal
C Min
Blade length
1.0 (25.4)
1.38 (34.9)
1.88 (47.6)
2.25 (57.2)
1.0 (25.4)
1.38 (34.9)
1.88 (47.6)
2.25 (57.2)
D Min
Barrel length
4.13 (104.8)
4.63 (117.5)
5.19 (131.8)
6.13 (115.6)
7.13 (118.1)
8.19 (208.0)
E
Blade thickness
0.13 (3.2)
0.19 (4.8)
0.25 (6.4)
0.25 (6.4)
0.13 (3.2)
0.19 (4.8)
0.25 (6.4)
0.25 (6.4)
3-pole
250V
HM25030-3
HM25060-3
HM25100-3
HM25200-3
HM25400-3
HM25600-3
options.
600V
HM60030-3
HM60060-3
HM60100-3
HM60200-3
HM60400-3
HM60600-3
F
Blade width
0.75 (19.1)
1.13 (28.6)
1.63 (41.3)
2 (50.8)
0.75 (19.1)
1.13 (28.6)
1.63 (41.3)
2 (50.8)
1007July 2015
Eaton.com/bussmannseries
7-3
1-pole
Amp
ratings
15, 20, 25, 30, 35, 40, 45, 50, 60
To Order
Catalog symbol
and volts
D
Dimensions
Dimensions - in (mm)
Typical applications
For use in circuits subject to surge currents such as those
caused by motors, transformers and other inductive loads
0.22
0.81
0.22
(20.57)
(5.56)
(5.56)
2.0
0.06
(1.59)
0.34
(50.8)
2.80
0.94
(8.73)
(71.04)
(23.81)
3.31
(84.14)
CGL 1-30
0.22
0.81
0.22
(20.64)
(5.56)
(5.56)
2.0
0.06
0.50
(50.8)
2.80
(1.59)
1.06
(12.7)
(71.04)
(26.92)
3.5
(88.9)
CGL 35-60
1.34
0.343
0.343
(34.04)
(8.71)
(8.71)
2.39
(60.72)
3.64
0.09
(2.29)
0.75
1.375
(19.05)
(34.93)
(92.47)
4.31
(109.54)
CGL 70-100
0.343
0.343
(8.71)
(8.71)
CGL-1
CGL-2
CGL-3
CGL-4
CGL-6
CGL-10
CGL-15
CGL-20
CGL-25
CGL-30
CGL-35
CGL-40
CGL-45
CGL-50
CGL-60
CGL-70
CGL-80
CGL-90
CGL-100
CGL-110
CGL-125
CGL-150
CGL-175
CGL-200
CGL-225
CGL-250
CGL-300
CGL-350
CGL-400
CGL-450
CGL-500
CGL-600
3.00
(38.1)
5.31
(134.87)
CGL 110-200
0.19
0.38
1.0
(9.53)
(4.76)
(25.4)
1.0
3.0
(25.4)
2.38
(76.2)
(60.33)
5.25
(133.35)
8.19
(207.96)
CGL 225-400
1.0
0.41
(25.4)
(10.32)
1.0
(25.4)
3.0
(76.2)
5.25
(133.35)
8.19
(207.96)
CGL 450-600
(3.18)
1.50
(19.05)
(109.22)
Fuse amps
Catalog symbol
1-32
RS32_
35-60
RS63_
70-100
RS100_
110-200
RS200_
225-400
RS400_
See Red Spot data sheet No. 10083 for details.
7-4
0.125
0.75
(76.2)
4.30
1007July 2015
Eaton.com/bussmannseries
0.60
(15.24)
0.375
(9.53)
3.00
(76.2)
CIF21 HRCI-CA
CIF06 HRCI-CB
Specifications
Description: The HRCI-CA fuse provides
both overload and short-circuit protection to
HRCI requirements. Offset blades for bolt-on
mounting. CIF21 fuse fits the Bussmann
series Rep Spot fuse holder (data sheet
10083) and CAMaster fuse holder
(data sheet 4132).
Dimensions: See dimensions illustration.
Construction: Ceramic body.
Ratings:
Volts: 600Vac
250Vdc
Amps: 1-30A
IR: 200kA RMS Sym.
Agency information: CE, CSA C22.2, No. 106-M92.
Mounting: Bolt-on.
Specifications
Description: A miniature industrial fuse that
provides both short-circuit and overload
protection and the CIF06 fits the 30A SAFEloc
fuse holder (data sheet 4133).
Dimensions: See dimensions illustration.
Construction: Ground ceramic body with
plated end caps.
Ratings:
Volts: 600Vac
250Vdc
Amps: 1-30A
IR: 200kA RMS Sym.
Agency information: CE, CSA C22.2 No. 106-M92 (3-30A
only).
Mounting: Clip-in offset blades.
Catalog numbers
Catalog
number
1CIF21
3CIF21
6CIF21
10CIF21
15CIF21
20CIF21
25CIF21
30CIF21
Catalog numbers
Catalog
number
1CIF06
3CIF06
6CIF06
10CIF06
15CIF06
20CIF06
25CIF06
30CIF06
Amp
rating
1
3
6
10
15
20
25
30
Typical applications
For use in circuits subject to surge currents such as those
caused by motors, transformers and other inductive loads
Amp
rating
1
3
6
10
15
20
25
30
Typical applications
For use in circuits subject to surge currents such as those
caused by motors, transformers and other inductive loads
Dimensions - in (mm)
2.15 (54.5)
1.44 (35.5)
0.19 (4.7)
0.54 (13.8)
0.44 (11.1)
1.75 (44.5)
0.03 (0.81)
2.38 (60.4)
1.44 (35.5)
Dimensions - in (mm)
0.5 (12.7)
0.54 (13.8)
0.03 (3.5)
0.14 (3.5)
Recommended fuse holders
SAFEloc P/N C30_
1007July 2015
Eaton.com/bussmannseries
7-5
Dimensions
CJ HRCI-J
Specifications
Description: HRCI-J fast-acting
fuses are industrial duty fuses with
the excellent current-limiting
characteristics of fast-acting HRCI-J
fuses to limit damage to equipment
and installations by the thermal and
magnetic energy associated with a
large short-circuit fault current.
Overload characteristics limit cable
damage due to low overload currents.
Dimensions: See catalog numbers table and dimensions
illustrations.
Construction: Ceramic body fuse.
Ratings:
Volts: 600Vac (or less)
250Vdc
Amps: 1-600A
IR: 200kA
Agency information: CSA C22.2 No. 106 M92; designed
to BS 88:2, IEC 60269-2.
70CJ to 600CJ
1CJ to 60CJ
A
K
H
G
Catalog numbers
Catalog numbers
Catalog
number
1CJ
3CJ
6CJ
10CJ
15CJ
20CJ
25CJ
30CJ
35CJ
40CJ
45CJ
50CJ
60CJ
70CJ
80CJ
90CJ
100CJ
110CJ
125CJ
150CJ
175CJ
200CJ
225CJ
250CJ
300CJ
350CJ
400CJ
450CJ
500CJ
600CJ
Amp
rating
1
3
6
10
15
20
25
30
35
40
45
50
60
70
80
90
100
110
125
150
175
200
225
250
300
350
400
450
500
600
Dimensions - in (mm)
E
2.25 (57)
0.5 (12.7)
0.81 (20.6)
2.38 (60)
0.63 (16)
1.06 (27)
4.63 (117)
3.63 (92)
1.13 (28)
0.75 (19)
0.13 (3.2)
1 (25.4)
0.5 (12.7)
0.28 (7.1)
0.38 (9.5)
2.63 (67)
5.75 (146)
4.38 (111)
1.63 (41)
1.13 (28.6)
0.19 (4.8)
1.38 (35)
0.69 (17.5)
0.28 (7.1)
0.38 (9.5)
3 (76)
7.13 (181)
5.25 (133)
2.13 (54)
1.63 (41)
0.25 (6.3)
1.88 (47.6)
0.94 (24)
0.41 (10.3)
0.53 (13.5)
3.38 (86)
8 (203)
6 (152)
2.63 (66)
2 (51)
0.38 (9.5)
2.13 (54)
1 (25.4)
0.53 (13.5)
0.69 (17.5)
3.75 (96)
1007July 2015
Eaton.com/bussmannseries
F
A
L
C
J
E
Catalog numbers
A Max
2.25 (57)
B Max
0.94 (24)
C Max
3.38 (86)
D Nom
0.38 (9.2)
Dimensions - in (mm)
E Nom
F Nom
G Nom
0.04 (1.0)
2.88 (73)
0.21 (5.2)
2.25 (57)
0.94 (24)
3.38 (86)
0.38 (9.2)
0.04 (1.0)
2.28 (58)
1.06 (27)
3.56 (91)
3.56 (91)
0.5 (12.7)
0.05 (1.2)
2.88 (73)
2.75 (70)
2.75 (70)
1.44 (37)
1.44 (37)
4.38 (111)
4.38 (111)
0.75 (19)
0.75 (19)
0.09 (2.5)
0.09 (2.5)
3.69 (94)
3.69 (94)
2.28 (58)
1.06 (27)
0.5 (12.7)
0.05 (1.2)
H Nom
0.31 (8)
J Max
1 (25.4)
K Nom
0.10 (2.6)
L Max
2.38 (60)
1 (25.4)
0.10 (2.6)
2.38 (60)
2.88 (73)
0.21 (5.2)
0.31 (8)
2.88 (73)
0.21 (5.2)
0.41 (10.5)
0.41 (10.5)
1.09 (28)
0.13 (3.2)
0.13 (3.2)
2.38 (61)
0.34 (8.7)
0.34 (8.7)
0.41 (10.5)
0.41 (10.5)
1.5 (38.5)
1.5 (38.5)
2.91 (74)
2.91 (74)
0.21 (5.2)
1.09 (28)
2.38 (61)
CAMaster holder
CM30CF
CM60CF
4132 (CAMaster).
1007July 2015
Eaton.com/bussmannseries
7-7
Standard fuses
Catalog
Amp
numbers ratings
1CIH07
1
3CIH07
3
6CIH07
6
10CIH07
10
15CIH07
15
20CIH07
20
25CIH07
25
30CIH07
30
35CIK07
35
40CIK07
40
50CIK07
50
60CIK07
60
80CIL14
80
90CIL14
90
100CIL14
100
Dimensions
HRC Form II
Specifications
Description: HRC Form II
current-limiting fuses.
Dimensions: See catalog
numbers table and dimensions
illustrations.
Construction: Ceramic body.
Ratings:
Volts: 600Vac (or less)
250Vdc
Amps: 2-600A
IR: 200kA RMS Sym.
Agency information: CE, CSA C22.2 No.106_M92;
BS 88:2, IEC 60269:2.
A
H
J
B
L09C/M09C/P09C
(Center blades)
E
K07C/K07CR/
L14C/M14C
(Offset blades)
H07C
(Offset blades)
Typical applications
Used to protect motor control circuits, together with
contactors and overload protection relays to provide Type 2
coordination - per IEC 60947-4.
D
H
P11C/R11C
(Center blades)
E
Catalog numbers
Catalog
Amp
number
rating
2H07C
2
4H07C
4
6H07C
6
10H07C
10
15H07C
15
20H07C
20
25H07C
25
30H07C
30
40K07C
40
50K07C
50
60K07C
60
80K07CR
80
100K07CR 100
80L14C
80
100L14C
100
125M14C* 125
150M14C* 150
200M14C* 200
80L09C*
80
100L09C*
100
125M09C
125
150M09C
150
200M09C
200
250P09C* 250
300P09C* 300
350P09C* 350
400P09C* 400
250P11C
250
300P11C
300
350P11C
350
400P11C
400
450R11C
450
500R11C
500
600R11C
600
A
1.38 (35)
1.38 (35)
2.19 (56)
2.19 (56)
2.19 (56)
B
0.56 (14)
0.56 (14)
0.88 (22)
0.88 (22)
0.88 (22)
C
3.38 (85)
3.38 (85)
0.5 (13)
4.38 (111)
0.56 (14.3)
(14.3)
0.56
3.75
3.75(95)
(95)
0.88 (21.4)
(21.4)
0.88
2.38
2.38 (60)
(60)
0.88 (21.4)
(21.4)
0.88
5 5(127)
(127)
3.06 (178)
2.31 (59)
5.38 (136)
3.06 (178)
3.06 (178)
2.31 (59)
2.31 (59)
8.25 (210)
3.19 (81)
3.19 (81)
2.88 (73)
2.88 (73)
2.56 (65)
2.56 (65)
1.5 (38)
1.5 (38)
1.5 (38)
1.5 (38)
0.38 (9)
3.44 (87)
3.44 (87)
2.38
2.38 (60)
(60)
2.56 (65)
2.56 (65)
Dimensions - in (mm)
E
F
0.06 (1.2)
2.88 (73)
D
0.38 (9)
4.38 (111)
5.38 (136)
8.25 (210)
8.25 (210)
0.5 (13)
0.5 (13)
0.75 (19)
0.75 (19)
0.56
0.56 (14)
(14)
0.75 (19)
0.75 (19)
0.06 (1.2)
0.31 (8)
0.06 (1.2)
2.88 (73)
0.22 (5.6)
0.22 (5.6)
0.31 (8)
0.06 (1.2)
2.88 (73)
0.22 (5.6)
0.31 (8)
0.09 (2.4)
0.09 (2.4)
3.69 (94)
0.34 (8.7)
0.13
0.13 (3.2)
(3.2)
4.38 (111)
4.38 (111)
0.34 (8.7)
0.13 (3.2)
(3.2)
0.13
0.13 (3.2)
3.69 (94)
4.38 (111)
4.38 (111)
1 (25.4)
1 (25.4)
0.19 (5)
5.25 (133)
1 (25.4)
0.25 (6.3)
0.25 (6.3)
5.25 (133)
5.25 (133)
H
0.31 (8)
2.88 (73)
0.19 (4.8)
1 (25.4)
G
0.22 (5.6)
0.19 (4.8)
0.19 (5)
0.34 (8.7)
0.34 (8.7)
0.34 (8.7)
0.34 (8.7)
J
K
0.56 (14)
0.56 (14)
CSA category
HRCII-C
HRCII-C
0.88 (22)
0.88 (22)
0.88 (22)
HRCII-MISC
HRCII-MISC
0.44 (11)
0.44 (11)
HRCII-MISC
0.56 (14)
0.56 (14)
0.44 (11)
0.44 (11)
11 (25.4)
(25.4)
0.41 (10)
0.63 (16)
0.41 (10)
0.41 (10)
0.63 (16)
0.63 (16)
0.5 (13)
0.5 (13)
1 (25)
1 (25)
1 (25)
1 (25)
HRCII-C
HRCII-C
HRCII-C
HRCII-MISC
HRCII-MISC
HRCII-C
HRCII-C
HRCII-MISC
HRCII-MISC
HRCII-C
HRCII-C
HRCII-C
Recommended fuse holders: Red Spot up to 400A (data sheet 10083) and CAMaster up to 100A (data sheet 4132).
1007July 2015
Eaton.com/bussmannseries
Specifications
Description: The NSD and ESD are low voltage
fuses complying with general purpose gG
characteristics.
Construction: Ceramic body.
Ratings:
Volts: 240-550Vac (see catalog numbers table)
Amps: 2-63A (see catalog numbers table)
20M25-63M100A motor starter ratings
(see catalog numbers table)
IR: 33kA (SSD)
80kA (NSD, ESD)
Agency information: CE, meets the requirements of
BS 88 Part 1 and IEC 60269-1.
Mounting: Offset blades.
Specifications
Description: The STD to DEO types are low
voltage fuses complying with general purpose gG
characteristics.
Construction: Ceramic body.
Ratings:
Volts: 240-550Vac (see catalog numbers
table)
Amps: 2-200A (see catalog numbers table)
20M25-200M315A motor starter ratings
(see catalog numbers table)
IR: 33kA (STD)
80kA (NITD, AAO, BAO, CEO, DEO, OSD)
Agency information: CE, meets the requirements of
BS 88 Part 1 and IEC 60269-1.
Mounting: Offset bolted blades.
Max AC
voltage
ratings
240
550
BS 88
ref.
E1
F1
550
415
F2
F2
415
To order
F1
To order, specify basic catalog number and amp rating. Example: SSD-20
Basic
catalog
numbers
STD
NITD
AAO
BAO
Typical applications
The STD type are used in 240V street lighting cut-outs
NITD to DEO types used for industrial and general purpose
applications
CEO
Holder catalog
numbers
32NNSF
63ENSF
DEO
OSD
Amp
ratings
2, 4, 6, 10, 16, 20, 25, 32
2, 4, 6, 10, 16, 20, 25, 32
20M25*, 20M32*, 32M40*, 32M50*, 32M63*
2, 4, 6, 10, 16, 20, 25, 32,
32M40*, 32M50*, 32M63*
40, 50, 63, 63M80*, 63M100*
32, 40, 50, 63, 80, 100
100M125*, 100M160*, 100M200*
125, 160, 200, 200M315*
80, 100
100M125*, 100M160*
Max AC
voltage BS 88
ratings ref.
240
550
415
550
500
500
A3
550
A4
415
415
500
415
To order
To order, specify basic catalog number and amp rating. Example: BAO-16
Block/holder
catalog numbers
CM32FC, RS20_
CM32F, RS32_
CM63F, RS63_
CM100F, RS100_
BH-0111
1007July 2015
Eaton.com/bussmannseries
7-9
Specifications
Description: Low voltage fuses that
comply with general purpose gG
characteristics and available up to 400A
with two hole mount and up to 1250A
with four hole mount.
Construction: Ceramic body.
Ratings:
Volts: 415/550Vac, 250Vdc (see
catalog numbers table)
Amps: 2-400A (see catalog numbers table)
63M80-400M500A motor starter ratings (see
catalog numbers table)
IR: See catalog numbers table
Agency information: CE, meets the requirements of
BS 88 Parts 1 and 2 and IEC 60269-1.
Mounting: Center bolted blades, two-hole mount.
Specifications
Description: Low voltage fuses
complying with general purpose gG
characteristics and available up to
400A with two hole mount and up
to 1250A with four hole mount.
Construction: Ceramic body.
Ratings:
Volts: 415/690Vac, 250/400Vdc
(see catalog numbers
table for details)
Amps: 355-1250
IR: see catalog numbers table
Agency information: CE, meets the requirements of
BS 88 Parts 1 and 2 and IEC269-1.
Mounting: Center bolted blades, four-hole mount.
Basic catalog numbers
CD
DD
ED
EFS
Amp
ratings
2, 4, 6, 10, 16, 20
25, 32
2, 4, 6, 10, 16, 20
25, 32
40, 50, 63
63M80*, 63M100*
40, 50, 63
80, 100,
100M125*, 100M160*,
100M200*, 100M200*
125, 160, 200,
200M250*, 200M315*
250, 315, 355, 400, 315M400*
400M500*
125, 160, 200, 250, 315
Interrupting
ratings (kA)
AC
DC
80
40
80
80
40
80
8
40
80
80
40
80
80
80
80
80
Max voltage
ratings
BS 88
AC
DC
ref.
550 250
500
550 250
500
500 250
500
500 250
500
B1
415
415
B2
415
415
Basic
catalog
numbers
EF
Interrupting
Max voltage
Amp
ratings (kA)
ratings
BS 88
ratings
AC
DC
AC
DC
ref.
355, 400
80
415
C1
400M500*
80
550
FF
450, 500, 560, 630
80
40
690
400
C2
FG
450, 500, 560, 630
80
40
550
400
GF
710, 800
80
40
550
250
C3
GG
710, 800, 1000, 1250
80
550
GH
710, 800, 1000, 1250
80
550
To order
To order, specify basic catalog number and amp rating. Example: FG-450
B4
To order
To order, specify basic catalog number and amp rating. Example: BC-40
Block/holder
catalog numbers
BH-0111 Modular fuse block
BH-____ Modular fuse block
BH-0111 Modular fuse block
BH-____ Modular fuse block
BH-____ Modular fuse block
BH-____ Modular fuse block
BH-1131 Modular fuse block
Data Sheets 4110 (AC), 4111 (AD), 4113 (BC), 4114 (BD),
4116 (CD), 4118 (DD), 4119 (ED) and 4121 (EFS)
7-10
Data Sheets 4120 (EF), 4102 (FF), 4122 (FG), 4103 (GF), 4104
(GG) and 4108 (GH)
1007July 2015
Eaton.com/bussmannseries
Specifications
Description: DIN style Type D
low voltage fuses.
Dimensions: See catalog
numbers table and dimensions
illustrations.
Construction: Ceramic body.
Ratings:
Volts: 500Vac
Amps: 2-100A
IR: 50kA
Agency information: CE, D type fuses complying with
DIN 49360 Part 2 and DIN 49515, operating class gL.
Catalog numbers
Catalog
numbers
2D16
4D16
6D16
10D16
16D16
20D16
25D16
2D27
4D27
6D27
10D27
16D27
20D27
25D27
35D33
50D33
63D33
80D125
100D125
Amp
ratings
2
4
6
10
16
20
25
2
4
6
10
16
20
25
35
50
63
80
100
Dimension
D (mm)
6
6
6
8
10
12
14
6
6
6
8
10
12
14
16
18
20
5
7
Color
code
Pink
Brown
Green
Red
Grey
Blue
Yellow
Pink
Brown
Green
Red
Grey
Blue
Yellow
Black
White
Copper
Silver
Red
Figure
number
1
Specifications
Description: Low voltage Neozed fuses
suitable for use on 250Vdc systems.
Dimensions: See catalog numbers table and
dimensions illustration.
Construction: Ceramic body.
Ratings:
Volts: 400Vac
Amps: 2-63A
IR: 50kA
Agency information: CE
Catalog numbers
Catalog
numbers
2NZ01
4NZ01
6NZ01
10NZ01
16NZ01
20NZ02
25NZ02
35NZ02
50NZ02
63NZ02
Amp
ratings
2
4
6
10
16
20
25
35
50
63
Dimension
D (mm)
11
11
11
11
11
15
15
15
15
15
Color
code
Pink
Brown
Green
Red
Grey
Blue
Yellow
Black
White
Copper
Dimensions - mm
D
3
4
36
Additional fuse links: Quick acting fuselinks in body sized D16, D27, D33 and
D125 rated 2-100A. Reference number suffixed Q, i.e. 10D27Q. Voltage rating 500V.
Gauge rings and keys can also be supplied.
Dimensions - mm
Figure 1
Figure 2
Figure 3
Figure 4
1007July 2015
Eaton.com/bussmannseries
7-11
NH HRC fuses
Volts: 500Vac
690Vac
Amps: 2-1250A
IR: 120kA
Frequency: 50Hz
Operating frequency: 45-62Hz
Agency information: IEC 60269, VDE 0636, DIN 43620
Part 1 to 4, VDE Mark and CE.
Ratings:
___NHG___B
Specifications
Class: gG/gL
Description: DIN
square bodied, dual
indication industrial
fuses.
Construction: Steatite
insulator, corrosionproof (aluminum) metal
parts with full-contact,
silver-plated copper
blades.
Sizes: DIN 000 to 4.
Selectivity ratio: 1:1.6 up to 500Vac.
Fuse blocks
SD00-D
SD1-D
SD2-D
Size
000-00
1*, 1
02, 2, 03, 3
Dimensions - mm
Fuse
size
000
00
0
01
1
02
2
03
3
4
a1
78.5 1.5
78.5 1.5
125 2.5
135 2.5
135 2.5
150 2.5
150 2.5
150 3
150 3
200
a2
(max)
54
54
68
75
75
75
75
75
75
84
45
45
62
62
62
62
62
62
62
80
a3
1.5
1.5
+3/-1.5
2.5
2.5
2.5
2.5
2.5
2.5
a4
49 1.5
49 1.5
68 +1.5/-3
68 2.5
68 2.5
68 2.5
68 2.5
68 2.5
68 2.5
90
b
(nom)
15
15
15
15
20
20
25
25
32
50
c1
( 8)
35
35
35
40
40
48
48
60
60
85
c2
(nom)
10
11
11
11
11
11
11
11
11
11
D
(nom)
2 0.5
7.0 0.5
2.5 0.5
2.5 0.5
2.5 0.5
2.5 0.5
2.5 0.5
2.5 0.5
3.0 0.5
3
e1
(max)
41
48
48
48
53
53
61
61
75
120
1007July 2015
Eaton.com/bussmannseries
e2
(max)
21
30
30
30
52
52
60
60
70
87
e3
(max)
16
25
25
25
25
25
25
25
25
e4
(nom)
6
6
6
6
6
6
6
6
6
8
f
(max)
8
15
15
15
15
15
15
15
18
30
NH HRC fuses
500Vac
Size
000
00
01
Rated
current
(amps)
Carton
quantity
2
4
6
10
16
20
25
32
35
40
50
63
80
100
50
63
80
100
125
160
6
10
16
20
25
32
35
40
50
63
80
100
125
160
6
10
16
20
25
32
35
40
50
63
80
100
125
160
2NHG000B
4NHG000B
6NHG000B
10NHG000B
16NHG000B
20NHG000B
25NHG000B
32NHG000B
35NHG000B
40NHG000B
50NHG000B
63NHG000B
80NHG000B
100NHG000B
50NHG00B
63NHG00B
80NHG00B
100NHG00B
125NHG00B
160NHG00B
6NHG0B
10NHG0B
16NHG0B
20NHG0B
25NHG0B
32NHG0B
35NHG0B
40NHG0B
50NHG0B
63NHG0B
80NHG0B
100NHG0B
125NHG0B
160NHG0B
6NHG01B
10NHG01B
16NHG01B
20NHG01B
25NHG01B
32NHG01B
35NHG01B
40NHG01B
50NHG01B
63NHG01B
80NHG01B
100NHG01B
125NHG01B
160NHG01B
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
500Vac
Size
Rated
current
(amps)
50
50NHG1B
63
63NHG1B
80
80NHG1B
100
100NHG1B
125
125NHG1B
1
160
160NHG1B
200
200NHG1B
224
224NHG1B
250
250NHG1B
315
315NHG1B
355
355NHG1B
35
35NHG02B
40
40NHG02B
50
50NHG02B
63
63NHG02B
80
80NHG02B
02
100
100NHG02B
125
125NHG02B
160
160NHG02B
200
200NHG02B
224
224NHG02B
250
250NHG02B
250
250NHG2B
300
300NHG2B
315
315NHG2B
355
355NHG2B
2
400
400NHG2B
425
425NHG2B
450
450NHG2B
500
500NHG2B
250
250NHG03B
315
315NHG03B
03
355
355NHG03B
400
400NHG03B
315
315NHG3B
355
355NHG3B
400
400NHG3B
425
425NHG3B
3
450
450NHG3B
500
500NHG3B
630
630NHG3B
800
800NHG3B
500
500NHG4G
630
630NHG4G
4*
800
800NHG4G
1000
1000NHG4G
1250
1250NHG4G
* Size 4 is for a fuse with a single indicator link with slotted end tags.
Carton
quantity
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
1
1
1
1
1
1007July 2015
Eaton.com/bussmannseries
7-13
NH HRC fuses
690Vac
Size
Rated
current
(amps)
Carton
quantity
2
2NHG000B-690
4
4NHG000B-690
6
6NHG000B-690
10
10NHG000B-690
000
16
16NHG000B-690
20
20NHG000B-690
25
25NHG000B-690
32
32NHG000B-690
35
35NHG000B-690
40
40NHG000B-690
50
50NHG000B-690
63
63NHG000B-690
50
50NHG00B-690
00
63
63NHG00B-690
80
80NHG00B-690
100
100NHG00B-690
125
125NHG00B-690
160*
160NHG00B-690
50
50NHG1B-690
63
63NHG1B-690
80
80NHG1B-690
1
100
100NHG1B-690
125
125NHG1B-690
160
160NHG1B-690
200
200NHG1B-690
224
224NHG1B-690
250
250NHG1B-690
200
200NHG2B-690
2
224
224NHG2B-690
250
250NHG2B-690
315
315NHG2B-690
250
250NHG3B-690
315
315NHG3B-690
3
355
355NHG3B-690
400
400NHG3B-690
425
425NHG3B-690
500
500NHG3B-690
4
630
630NHG4B-690
800
800NHG4B-690
* 160 amps rated at 660Vac.
** Size 4 is for a fuse with a single indicator link with slotted end tags.
7-14
1007July 2015
Eaton.com/bussmannseries
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
1
1
NH fuse bases
Catalog numbers
SD*-D, SD*-S
Up to 690V / 160 - 1250A
sizes 000 to 4
Size
Amps: up to 1250A
SD00-D
TD00-D
SD1-D
250A
400A
3
1
630A
160A
Carton Compatible
quantity fuse siz e
DIN screw
1
00
Ratings:
Catalog
numbers
Current
(amps )
Poles
TD1-D
SD2-D
TD2-D
SD3-D
TD3-D
01
and
1
02
and
2
03
and
3
SD4-S (Screw
1250A
000
and
00
connection only)
Neutral
NH size
Amps
Catalog
number
Carton
quantity
250
SDL-1
400
SDL-2
630
SDL-3
Catalog
number
Carton
quantity
C00-3
FEH
Protection accessories
Current
(amps)
00*
0
1
2
3
160A
160A
250A
400A
630A
Terminal cover
1
Catalog
number
CS00*
CS0
CS1
CS2
CS3
Catalog numbers
Kit description
TD00-IP20
TD1-IP20
TD2-IP20
TD3-IP20
SD12-SK
SD3-SK
Carton
quantity
6
6
6
6
6
Catalog number
SD12-PB
SD3-PB
SD3
Separator
3
Catalog
number
BC00*
BC0
BC1-2
BC1-2
BC3
Carton
quantity
2
2
2
2
2
Shroud kits
NH
Size
1007July 2015
Eaton.com/bussmannseries
7-15
With indicator
C08G2I
C08G4I
C08G6I
C08G8I
C08G10
C08G12
C08G16
C08G20
C08G10I
C08G12I
C08G16I
C08G20I
Rated voltage
(Vac)
400
Amps
0.5
1
2
4
6
8
Interrupting rating at
rated voltage
(kA)
20
10
12
16
20
With indicator
C10G1I
C10G2I
C10G4I
C10G6I
C10G8I
C10G10I
C10G12I
C10G16I
C10G20I
C10G25I
C10G32I
C10G321
C10G40I
C10G50I
Rated voltage
(Vac)
500
400
400
500
500
400
Amps
0.5
1
2
4
6
8
10
12
16
20
25
32
32
32
40
50
Interrupting rating
at rated voltage
(kA)
120
Recommended
fuse holder
CHM
DIN-Rail*
BMM
modular block
With indicator
C14G1I
C14G2I
C14G4I
-
With striker
C14G2S
C14G4S
C14G6
C14G8
C14G10
C14G12
C14G16
C14G20
C14G25
C14G32
C14G40
C14G50
C14G6I
C14G8I
C14G10I
C14G12I
C14G16I
C14G20I
C14G25I
C14G32I
C14G40I
C14G50I
C14G6S
C14G8S
C14G10S
C14G12S
C14G16S
C14G20S
C14G25S
C14G32S
C14G40S
C14G50S
Rated voltage
(Vac)
690
500
690
500
690
500
690
500
690
500
690
500
690
500
690
500
690
500
400
Amps
1
2
4
6
8
10
12
16
20
25
32
40
50
Interrupting rating
at rated voltage
(kA)
Recommended
fuse holder
80
120
80
120
80
120
80
120
80
120
80
120
80
120
80
120
80
CH14
DIN-Rail**
120
D
7-16
1007July 2015
Eaton.com/bussmannseries
With indicator
C22G2I
C22G4I
C22G6I
C22G8I
C22G10I
C22G12I
C22G16I
C22G20I
C22G25I
C22G32I
C22G40I
C22G50I
C22G63I
C22G80I
C22G100I
C22G125I
With striker
C22G4S
C22G6S
C22G8S
C22G10S
C22G12S
C22G16S
C22G20S
C22G25S
C22G32S
C22G40S
C22G50S
C22G63S
C22G80S
C22G100S
C22G125S
Rated voltage
(Vac)
690
500
400
Amps
2
4
6
8
10
12
16
20
25
32
40
50
63
80
100
125
Interrupting rating
at rated voltage
(kA)
80
Recommended
holder/block
CH22
DIN-Rail*
JM70100
modular block
120
* Not recommended for use with indicator version, use striker version to acutate optional, external microswitch.
Dimensions - mm
C
Catalog symbol
C08M
C10M
C14M
C22M
A
8
10
14.3
22
B
31.5
38
51
58
C
6.3
10
13
16
Indicator/striker
D
E
8
4
8
4
1007July 2015
Eaton.com/bussmannseries
7-17
Catalog numbers
C08M1
C08M2
C08M4
C08M6
C08M8
400
Amps
Interrupting rating
at rated voltage
(kA)
1
2
4
6
8
20
With indicator
C10M0-25
C10M0-5
C10M1
C10M2
C10M4
C10M6
C10M8
C10M10
C10M12
C10M16
C10M20
C10M25
C10M1I
C10M2I
C10M4I
C10M6I
C10M8I
C10M10I
C10M12I
C10M16I
C10M20I
C10M25I
Rated voltage
(Vac)
500
400
Amps
0.25
0.5
1
2
4
6
8
10
12
16
20
25
Interrupting rating
at rated voltage
(kA)
120
Recommended
fuse holder
CHM
DIN-Rail*
BMM
modular block
With indicator
With striker
C14M0-25
C14M0.5
C14M1
C14M2
C14M4
C14M6
C14M8
C14M10
C14M12
C14M16
C14M20
C14M25
C14M32
C14M40
C14M50
C14M1I
C14M2I
C14M4I
C14M6I
C14M8I
C14M10I
C14M12I
C14M16I
C14M20I
C14M25I
C14M32I
C14M40I
C14M50I
C14M2S
C14M4S
C14M6S
C14M8S
C14M10S
C14M12S
C14M16S
C14M20S
C14M25S
C14M32S
C14M40S
C14M50S
Rated voltage
(Vac)
690
500
690
500
690
500
690
500
690
500
690
500
690
500
690
500
690
500
400
Amps
0.25
0.5
1
2
4
6
8
10
12
16
20
25
32
40
50
Interrupting rating at
rated voltage (kA)
120
80
80
120
80
120
80
120
80
120
80
120
80
120
80
120
80
120
80
120
** Not recommended for use with indicator version, use striker version to acutate optional, external microswitch.
7-18
1007July 2015
Recommended
fuse holder
Eaton.com/bussmannseries
CH14
DIN-Rail**
With indicator
With striker
C22M2
C22M4
C22M6
C22M8
C22M10
C22M12
C22M16
C22M20
C22M25
C22M32
C22M40
C22M50
C22M63
C22M80
C22M100
C22M125
C22M2I
C22M4I
C22M6I
C22M8I
C22M10I
C22M12I
C22M16I
C22M20I
C22M25I
C22M32I
C22M40I
C22M50I
C22M63I
C22M80I
C22M100I
C22M125I
C22M12S
C22M16S
C22M20S
C22M25S
C22M32S
C22M40S
C22M50S
C22M63S
C22M80S
C22M100S
C22M125S
Rated voltage
(Vac)
Amps
Interrupting rating
at rated voltage
(kA)
2
4
6
8
10
12
16
20
25
32
40
50
63
80
100
125
690
500
400
80
Recommended
holder/block
CH22
DIN-Rail*
JM70100
modular block
120
* Not recommended for use with indicator version, use striker version to acutate optional, external microswitch.
Dimensions - mm
C
Catalog symbol
C08M
C10M
C14M
C22M
A
8
10
14.3
22
B
31.5
38
51
58
C
6.3
10
13
16
Indicator/striker
D
E
8
4
8
4
1007July 2015
Eaton.com/bussmannseries
7-19
CAMaster
SAFEloc
Specifications
Catalog symbol:
See table below.
Description: The
Bussmann series CAMaster
HRC fuse holder features a
unique cam-action for easy
fuse removal while allowing
significantly improved
contact pressure between
fuse carrier and base
contact that enhances
electrical performance. A range of lockable safety carriers for
the fuse holder (catalog reference: LSC), are available.
Ratings:
Volts: 690V
Amps: up to 100A (see catalog number table for details)
Agency information: CE, CSA C22.2 No. 39; IEC 269
AND BS 88.
Mounting: 35mm DIN-Rail or single screw mounting.
Specifications
catalog symbol:
See table below.
Description: The
Bussmann series
SAFEloc HRC fuse
holders (for use with
HRCI-CB fuses)
provides a positive,
stress-free fuse fitting
and locks it in position
to ensure safe insertion and
withdrawal from the base. Base contacts are fully shrouded
to help protect against electric shock. Shrouds utilize
simple slide/snap action allowing access to the contact
terminal screws.
Ratings:
Volts: 600V
Amps: 30-60A (see catalog number table for details)
Agency information: CE, designed to accommodate the
compact range of offset blade fuse to CSA C22.2 No. 106,
HRCI-CB.
Mounting: 35mm DIN-Rail or single screw mounting.
Catalog numbers
Catalog
numbers
CM20CF
CM30CF
CM60CF
CM100CF
Amp
ratings
30
30
60
100
Details for:
HRCI-CA applications
HRCII applications
Fuse
accepted
_CIF21
_H07C
_K07C
_K07CR
Amp
ratings
30
30
60/100
All
30
30
60/100A
Details
Back stud
Fuse holder
accepted
CM20CF
CM30CF
CM60/100CF
3-Pole
CM20CF
CM30CF
CM60/100CF
Catalog numbers*
Catalog
Amp
numbers
ratings
Connection
C30F
Front
C30BS
30
Back
C30FBS
Front-back
C60F
Front
C60BS
60
Back
C60FBS
Front-back
*For use with HRCI-CB fuses.
Bussmann series
Red Spot fuse holders
7-20
1007July 2015
Eaton.com/bussmannseries
Fuse
accepted
_CIF06
EK-Amp
Contents
Description
Page
Quik-Spec coordination panelboards . . . . . . . . . . . . . . . . . . . . 8-2
Quik-Spec power module switches and panels . . . . . . . . . . . . 8-4
Quik-Spec DC safety switches. . . . . . . . . . . . . . . . . . . . . . . . . 8-6
Quik-Spec AC safety switches. . . . . . . . . . . . . . . . . . . . . . . . . 8-7
A/C disconnects - fused and non-fused . . . . . . . . . . . . . . . . . 8-8
Quik-Spec
electrical
gear
1007July 2015
Eaton.com/bussmannseries
8-1
Specifications:
Description: Configurable fusible panelboard with 30-400A
mains and branches from 1-100A rated 600Vac.
Ratings:
Volts: 600Vac (or less), 125Vdc (or less)**
Bus Amps: 30, 60, 100, 200, 225 or 400A
Options:
Main:
Enclosure:
1007July 2015
Eaton.com/bussmannseries
Specifications:
Description: Fusible panelboard with 600, 800 and 1200A
mains and branches from 1-600A, rated 600Vac.
Ratings:
Volts: 600Vac (or less), 125Vdc
Amps: 600, 800 and 1200A
Options:
Main: Main lug only
Enclosure: NEMA 1 floor mount
Branch: 1-, 2- and 3-pole, 15-600A branch disconnect
Fuse: Time-delay, non-indicating (Class CFTCF_R
and/or Class J LPJ_SP)
Time-delay, indicating (Class CFTCF_ and/or
Class J LPJ_SPI)
Fast-acting, non-indicating (Class CFTCF_RN
and/or Class J JKS)
DFJ high speed Class J fuses
Agency information: Complies with NFPA 70 (NEC;
National Electrical Code) UL Listed to UL 67,
Features and benefits:
Configurable panelboards with options for 600, 800 and
1200A mains and branches from 1-600A all rated 200kA
SCCR at 600Vac
Smallest standard fusible panelboards in the industry
Featuring the finger-safe ULClass CFCUBEFuse with
1-100A ampacity rejection features that help prevent over
fusing
Available with time-delay or UPS/Critical application
fast-acting fuses
Ordering:
The QSCP is factory configured to the specific electrical
system. Contact your Eaton distributor or representative to
place your order. Have all relevant electrical and circuit information on hand.
600A
800A
(18) 1-100A
(18) 1-100A + 200A single
(18) 1-100A + 200A twin
200A single + 200A single
200A single + 200A twin
200A twin + 200A twin
(2) 300A single
(18) 1-100A + 200A single
(18) 1-100A + 200A twin
(2) 200A twin
(18) 1-100A + 400A single
200A twin + 400A single
(2) 400A single
(18) 1-100A + 600A single
(3) 200A twin
200A twin + 600A single
(2) 200A twin + 400A single
(3) 400A single
600A single + 400A single + 200A single
600A single + 400A single + 200A twin
(2) 600A single
Dimension
(inches)
H W D
65
27 15
89
38 15
65
38 15
89
38 15
89
38 15
Quik-Spec
electrical
gear
1200A
Branch configurations
102 38 15
1007July 2015
Eaton.com/bussmannseries
8-3
PS and PMP
Bussmann series Quik-Spec Power Module
Specifications:
Description: Fusible power switch or panel with shunt trip
and fire safety interface to allow for single point tie in with fire
alarm system.
Ratings:
Volts: 600Vac, 3
Amps: 30-400A (PS)
30-200A (PMP feeder switches)
400-800A (PMP main switches*)
Assembly
SCCR: 200kA RMS
Typical applications:
Elevator disconnects
Computer room shunt trip disconnect
Fire safety interface relay
Accessories:
For added safety, use the Bussmann series SAMI fuse
covers to improve maintenance personnel protection
(OSHA 1910.333, paragraph C)
Elevator shutdown
Ordering:
PMP*
Power Module Panel (PMP) for multiple elevator
applications.
Class J fuses
inspection
required
*Fused main disconnect requires Class J fuses, not supplied with switch.
1007July 2015
Eaton.com/bussmannseries
Hydraulic elevators
Scenario
Power failure
Fire in shaft or
machine room
Disconnect manually
opened
Fault on loadside of
disconnect
Battery
lowering
required
Yes
No
No
Yes
Reason
Need to lower elevator to allow passengers to exit.
Recall is initiated by smoke detector and lowers elevator to
a safe floor. Battery not needed.
Worker to perform maintenance. Elevator must remain
stationary to prevent injury.
Need to lower elevator to allow passengers to exit.
Offered by
Power
Module
Yes
Offered by
other elevator
disconnects
Yes
Yes
Yes
Yes
Yes
Yes
No
G N1 B
F1
1 = 100A
2 = 200A
4 = 400A
Control transformer*
T20 = 208 volt
T24 = 240 volt
R2 = 24Vdc coil
R = Red
W = White
N2 = 200A
N4 = 400A
Auxiliary contacts
B = 2 NO/NC
Fire alarm voltage monitoring relay (to monitor shunt trip voltage)
F1 = Single-pole
F3 = Three-pole**
Z = Type 12
Y = Type 4
** Only for use with R1 option
Neutral lug rating should be equal to or greater than the switch amp rating.
1007July 2015
Eaton.com/bussmannseries
Volts
480V
480V
208V
480V
208V
Quik-Spec
electrical
gear
8-5
Door interlock
Conduit knockouts
For easy conductor installation
Type 3R dimensions
Amps
30
60
100
200
16.35
16.35
22.15
28.27
8.87
8.87
11.84
16.66
9.89
9.89
9.89
11.26
ISC
Dimensions - in
19.2
38.4
64.0
128.0
30 and 60
Non-fusible
30 and 60
Fusible
100
200
ISC
14.14
8.76 10.22 #2 AWG - #14 AWG Al/Cu #4 AWG - #14 AWG Al/Cu 19.2
19.08
8.76 10.22 #2 AWG - #14 AWG Al/Cu #4 AWG - #14 AWG Al/Cu 19.2
24.95 11.79 10.22 1/0 AWG- #14 AWG Al/Cu #4 AWG - #14 AWG Al/Cu 64.0
35.38 16.95 11.63 250kcmil - #6 AWG Al/Cu #2 AWG - #14 AWG Al/Cu 128.0
BD
Voltage
BD = Heavy duty
DC safety switch
6 = 600Vdc
Poles
1 = 1-Pole
8-6
Prefix
Type
F = Fusible with
neutral
N = Non-fusible with
neutral
Amps
1 = 30A
2 = 60A
3 = 100A
4 = 200A
Enclosure type
R = NEMA 3R
D = NEMA 12
W = NEMA 4X
Stainless
1007July 2015
Eaton.com/bussmannseries
Non-Fused
Line
Line
Neutral
Neutral
Load
Load
Standard features:
Extended line terminal shield and finger-safe 30, 60, or
100A Bussmann series CUBEFuse
200kA short-circuit current rating
Visible double break quick-make, quick-break rotary blade
mechanism
Triple padlocking capability
Mechanically interlocked door
600Vac/250Vdc maximum
Optional features:
Viewing window for visible blades and open fuse indication
NEMA 1, 3R, 12, 4X (stainless)
Suitable for use as service equipment (with neutral kit)
Dimensions - inches (mm)*
NEMA 1 and 3R
Specifications:
Description: The Bussmann series CUBEFuse Safety
Switch equipped with finger-safe CUBEFuse provides
superior safety and reliability for industrial customers.
Agency Information:
UL 98 standard for enclosed deadfront switches.
UL 50 standard for enclosures for electrical equipment.
NEMA KS 1.
UL Listed, File E5239.
cULListed to C22.2 No.4-M89.
Quik-Spec
Electrical
Gear
1007July 2015
Eaton.com/bussmannseries
8-7
Series B22__
Specifications:
Description: Fused and non-fused rainproof pullout air
conditioner units.
Dimensions: See catalog numbers table.
Construction: NEMA 3R metal housing with weather resistant
coating.
Wire Range: 14-3 AWG, Al/Cu
Ratings:
Phase: Single, 2-wire
Volts: 240Vac
Amps: 30-60A
Agency information: UL Listed to UL 1429, cUL Certified,
UL Guide WGEW
Metallic non-fused
disconnect with
weather resistanttamper resistant
GFCI receptacle.
Typical applications:
Residential, light industrial/commercial A/C and heat pump service.
Spas/whirlpools, swimming pools, pump houses.
Suitable for service entrance equipment applications with field
installable ground bar, kit number DPFG.
Catalog numbers
Fused
Catalog numbers Description
B221-30F
30A, Pullout
B221-30FGF
30A, Pullout w/ GFCI
B221-30FGFWRTR 30A, Pullout w/ WRTRRated GFCI
B222-60F
60A, Pullout
B222-60FGF
60A, Pullout w/ GFCI
B222-60FGFWRTR 60A, Pullout w/ WRTRRated GFCI
Non-fused
B222-60NF
B222-60NFGF
B222-60NFGFWRTR
B222-60NFNA
60A, Pullout
60A, Pullout w/ GFCI
60A, Pullout w/ WRTRRated GFCI
60A, Switch
3
3
3
10
10
10
60A
60A
60A
3
3
3
10
10
10
60A
10
Wire range
60 or 75C Cu/Al
#14-3
#14-3
#14-3
Enclosure
type
NEMA 3R
NEMA 3R
NEMA 3R
Fuse
Class
H or R
H or R
H or R
#14-3
#14-3
#14-3
NEMA 3R
NEMA 3R
NEMA 3R
*
*
*
#14-3
#14-3
#14-3
#14-3
NEMA 3R
NEMA 3R
NEMA 3R
NEMA 3R
1007July 2015
Eaton.com/bussmannseries
H or R
H or R
H or R
5 38
7 12
7 12
2 78
4 34
4 34
8 34
11 34
11 34
5 38
6 12
6 12
2 78
4 12
4 12
8 34
5 38
3 58
Contents
1007July 2015
Eaton.com/bussmannseries
9-1
Fuse holders
and blocks
Description
Page
CH global modular fuse holders
and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-2
Remote fuse monitoring - CH-PLCCH . . . . . . . . . . . . . . . . . 9-6
Comb-bus bar specifications and selection guide . . . . . . . . . 9-7
Comb-bus bar features and installation guide . . . . . . . . . . . . 9-8
CH Class J modular fuse holders . . . . . . . . . . . . . . . . . . . . . . 9-9
OPM-1038(R)SW(C) 3-pole fuse holders with
disconnect switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-10
OPM-1038 3-pole fuse holders . . . . . . . . . . . . . . . . . . . . . . 9-11
OPMNGA- 3-pole Class CC and 13/32 X 1 1/2
fuse overcurrent protection modules . . . . . . . . . . . . . . . . . . 9-12
JT(N)60030 and JT(N)600600 Safety J Class J
fuse holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-14
SAMI fuse covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-16
Modular knifeblade fuse holders
Class R, H(K), 250 and 600V . . . . . . . . . . . . . . . . . . . . . . . 9-17
Class J, 600V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-21
Class J power distribution fuse block . . . . . . . . . . . . . . . . . . 9-22
Class H(K), J and R module ferrule fuse blocks
250 and 600V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-24
JP Class J fuse blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-31
Class CC and supplemental modular ferrule fuse blocks
BCM and BMM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-32
1000Vdc modular photovoltaic ferrule fuse blocks
BPVM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-34
T300 300V Class T fuse blocks . . . . . . . . . . . . . . . . . . . . . . 9-36
T600 600V Class T fuse blocks . . . . . . . . . . . . . . . . . . . . . . 9-38
Class G fuse blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-40
BH high speed fuse modular fuse blocks . . . . . . . . . . . . . . . 9-41
Class H and J modular fuse blocks . . . . . . . . . . . . . . . . . . . 9-41
Plug fuse box cover units . . . . . . . . . . . . . . . . . . . . . . . . . . .9-42
HFB and HFB-10 in-line fuse holders
for 1/4 X 1 1/4 fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-43
HHB and HRK universal in-line fuse holders for
1/4 dia. fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-43
HR and HM in-line fuse holders for 1/4 dia. fuses . . . . . . . . . 9-44
HFA waterproof in-line fuse holders
for 1/4 X 1 1/4 fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-44
HHT in-line fuse holders for
5 X 15 to 20mm fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-44
HE_ in-line fuse holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-45
HEB in-line fuse holders for 13/32 X 1 1/2 fuses . . . . . . . . . . .9-46
Panel mounted fuse holders for 5 X 20mm fuses . . . . . . . . . . . 9-48
Panel mounted fuse holders for 1/4 X 1 1/4 fuses . . . . . . . . . 9-49
Panel mounted fuse holders for 5 X 20mm and
1/4 X 1 1/4 fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-50
Panel mounted fuse holders for indicating type fuses . . . . . . . . 9-52
Panel mounted fuse holders for
13/32 X 1 5/16 to 1 1/2 fuses . . . . . . . . . . . . . . . . . . . . . .9-53
Panel mounted fuse holders for
13/32 X 1 1/2 fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-54
Fuse blocks for 1/4 X 1 1/4 fuses . . . . . . . . . . . . . . . . . . . . . 9-55
Fuse blocks for 1/4 X 1 fuses . . . . . . . . . . . . . . . . . . . . . . . . .9-56
Fuse blocks for 13/32 X 1 1/2 fuses . . . . . . . . . . . . . . . . . . . .9-57
Rail mount fuse holders and blocks . . . . . . . . . . . . . . . . . . . . . 9-58
Features/benefits
High SCCR rated, UL Listed Class CC holder with indicator
option for 600Vac/dc and 48Vdc.
UL Recognized midget and 10 x 38 holders with factory
assembled neutral pole option.
Agency ratings up to 1000Vdc for use with 10 x 38 solar
PV fuses.
Available remote PLC indication with the CH-PLC module.
Terminals rated for use with 75C or 90C wire, fine
stranded wire, spade terminals and comb-bus bars. Use
any higher temperature rated wire with appropriate
derating.
Complete range of UL Listed and high SCCR rated
1-phase and 3-phase finger-safe comb-bus bars and
power feed lugs.
Symbol
and size
CHM
10X38
and
Midget
Catalog numbers
With
Without
indicator
indicator
CHM1DIU
CHM1DU
CHM2DIU
CHM2DU
CHM3DIU
CHM3DU
CHM4DIU
CHM4DU
CHM1DCIU
CHM1DCU
CHM2DCIU
CHM2DCU
CHM3DCIU
CHM3DCU
CHM4DCIU
CHM4DCU
CHM1DNIU
CHM1DNU
CHM3DNIU
CHM3DNU
CHM1DI-48U
CHM1DNXU
CHPV
CHCC
Class CC
CHPV1IU
CHPV1U
CHPV2IU
CHPV2U
CHCC1DIU
CHCC2DIU
CHCC3DIU
CHCC1DI-48U
CHCC1DU
CHCC2DU
CHCC3DU
Voltage
and current
UL
600V/30A;
IEC
690V/32A
UL
600Vac/30A
1000Vdc/30A
IEC
690V/32A
UL
600V/30A;
IEC
690V/32A
UL 48Vdc/30A;
IEC
48Vdc/32A
IEC 690V/32A
UL and
IEC;
1000Vdc/30A
UL 600V/30A
Agency
markings
UR; IEC
60269-2;
CSA; CCC;
CE
UR; IEC
60269-2
CSA; CE
IEC
60269-2;
CE
UR; IEC
60269-2;
CSA; CCC; CE
IEC 60269-2; CE
UL; CSA; CE
UL 4248-18;
IEC 60269-1; CCC
UL; CSA;
CCC; CE
UL 48Vdc/30A
Number
of poles
1
2
3
4
1
2
3
4
Solid,
200kA*
stranded,
RMS Sym
fine
1 pole + 1 stranded,
spade
Neutral
3 pole + lug, comb
bus bar;
1 neutral
single and
dual wire;
1
75C and
90C Cu
1 neutral
N/A
wire
33kA
1
2
1
2
3
1
9-2
1007July 2015
Terminal Withstand
rating
rating
Eaton.com/bussmannseries
200kA
rms sym
Bussmann
series fuses
FNQ, KLM,
FNM, KTK,
BAF, FWA,
PVM, C10,
AGU, BAN,
FWC
N/A
PV, PVM
Solar PV
LP-CC,
FNQ-R, KTK-R
Series: CHCC
Series: CHM
Wire Range
18-14 AWG
(0.8-2.0mm2)
18-16 AWG
(0.8-1.3mm2)
14-10 AWG
(2.0-5.2mm2)
12-10 AWG
(3.3-5.2mm2)
Single
Solid,
Stranded
Dual
18-14 AWG
(0.8-2.0mm2)
Stranded,
Fine
Stranded
Spade
Terminal
N/A
Comb Bus
8-4 AWG
(8.3-21.1mm2)
Series: CHPV
Torque
Wire Range
20 in-lbs
2.3 Nm
25 in-lbs
2.8 Nm
18-14 AWG
(0.8-2.0mm2)
18-16 AWG
(0.8-1.3mm2)
14-10 AWG
(2.0-5.2mm2)
12-10 AWG
(3.3-5.2mm2)
Conductor
No. of
Type
Conductors
Single
Solid,
Stranded
Stranded,
8-4 AWG
Fine
(8.3-21.1mm2)
Stranded
18-14 AWG
Spade
(0.8-2.0mm2) Terminal
30 in-lbs
3.4 Nm
Single
N/A
Dual
Torque
Conductor
No. of
Type
Conductors
Wire Range
20 in-lbs
2.3 Nm
25 in-lbs
2.8 Nm
18-14 AWG
(0.8-2.0mm2)
18-16 AWG
(0.8-1.3mm2)
14-10 AWG
(2.0-5.2mm2)
12-10 AWG
(3.3-5.2mm2)
30 in-lbs
3.4 Nm
Single
Solid,
Stranded
Dual
Stranded,
8-4 AWG
Fine
(8.3-21.1mm2)
Stranded
18-14 AWG
Spade
(0.8-2.0mm2) Terminal
Single
Comb Bus
N/A
Torque
20 in-lbs
2.3 Nm
25 in-lbs
2.8 Nm
30 in-lbs
3.4 Nm
Single
Comb Bus
UL4248-18
Rated: 1000Vdc, 30A 33kA RMS SYM
Indication Min Voltage: 90V
IEC: 60269-1 32A
1000Vdc 33kA 3.5W
Degree of Protection IP20
GB13539
GB13539
MADE IN
CHINA
4GY1
MADE IN
CHINA
MADE IN
CHINA
Features
4mm
Lockout
Feature in
Fuse Carrier
GB13539
430P
Multi-pole ganging
Hole for Wire
Security Tag
Optional
Open Fuse
Indicator
Label Slot
Self-Extinguishing,
UL 94V0 Rated
Polyester
Material
Captive, Fully
Backed Out
Phil-Slot Screw
Spade lug
connection
6mm Wire
Clamp Lug and
open bus bar
connection
(#4 to #18)
Toolless
Ganging of
Multiple
Poles
Toolless DIN Rail
Mounting
Wire Strip
Length
Indicator
Fuse holders
and blocks
1007July 2015
Eaton.com/bussmannseries
9-3
Dimensions - mm (in)
(CHCC, CHM and CHPV)
70
[ 2.756 ]
52.5
[ 2.067 ]
35
[ 1.378 ]
61.83
[ 2.434 ]
17.5
[ 0.689 ]
73.88
[ 2.909 ]
18.59
[ 0.732 ]
42.58
[ 1.676 ]
52.83
[ 2.080 ]
9
[ 0.354 ]
83.19
[ 3.275 ]
7.0
[ 0.276 ]
Removing instructions
1. Press down on top
of DIN-Rail
2. Rotate out
on the bottom
9-4
1007July 2015
Eaton.com/bussmannseries
PV
UL
Catalog numbers
Without
indication
CH081D
CH081DNX
CH081DNS
CH081DN
CH082D
CH083D
CH083DNS
CH083DN
CH084D
CHM1DU
CHM2DU
CHM3DU
CHM4DU
CHM1DCIU
CHM2DCIU
CHM3DCIU
CHM4DCIU
CHM1DNU
CHM3DNU
CHM1DNXU
CHPV1U
CHPV2U
CHCC1DU
CHCC2DU
CHCC3DU
CH141B
CH141BMS
CH141BNX
CH141BN
CH142B
CH143B
CH143BMS
CH143BN
CH143BNMS
CH144B
CH221B
CH221BMS
CH221BNX
CH221BN
CH222B
CH223B
CH223BMS
CH223BN
CH223BNMS
CH224B
With*
indication
CH081DI
CH081DNSI
CH081DNI
CH082DI
CH083DI
CH083DNSI
CH083DNI
CH084DI
CHM1DIU
CHM2DIU
CHM3DIU
CHM4DIU
CHM1DCU
CHM2DCU
CHM3DCU
CHM4DCU
CHM1DNIU
CHM3DNIU
CH141BI
CH141BNI
CH142BI
CH143BI
CH143BNI
CH144BI
Not
Available
with
local
neon
indication
(remote
microswitch
only)
CH08
8x32
CHM
10X38
and
Midget
With
indication*
CH60J1
CH60J2
CH60J3
CH60J1I
CH60J2I
CH60J3I
CH30J1I
CH30J2I
CH30J3I
CHPV
CHCC
Class CC
CH14
14x51
CH22
22x58
CH30J
30A
Class J
CH60J
60A
Class J
Max
voltage
and Current
IEC
400Vac
25A
UL
600V/30A;
IEC
690V/32A
UL 600Vav/30A
1000Vdc/30A
IEC
690V/32A
UL 600V/30A;
IEC 690V/32A
UL 48Vdc/30A;
IEC
48Vdc/32A
IEC 690V32A
UL & IEC;
1000Vdc/30A
UL
600V/30A
UL 48Vdc/30A
UL
600Vac/dc
40A
(5 Watt)
IEC
690Vac,
50A
UL
600Vac/dc,
100A
(9.5 Watt)
IEC
690Vac,
125A
UL/CSA
600Vac
UL/CSA
600Vac
IEC
UL
*
*
*
*
*
*
*
*
*
*
**
**
**
**
UL LIsted (cULus)
14x51 IEC
No. of
17.5mm
modules Wire range
Phase configuration
1-pole
1 Neutral Pole
1-pole + Neutral
1-pole + Neutral
2-pole
3-pole
3-pole + Neutral
3-pole + Neutral
4-pole
1
1
1
2
2
3
3
4
4
1-pole
2-pole
3-pole
4-pole
1-pole
2-pole
3-pole
4-pole
1-pole + Neutral
3-pole + Neutral
1
2
3
4
1
2
3
4
2
4
1-pole
1-pole + Neutral
1-pole
2-pole
1-pole
2-pole
3-pole
1-pole
1-pole
1-pole + Microswitch
1 Neutral Pole
1-pole + Neutral
2-pole
3-pole
3-pole + Microswitch
3-pole + Neutral
3-pole + Neutral + Microswitch
4-pole
1-pole
1-pole + Microswitch
1 Neutral Pole
1-pole + Neutral
2-pole
3-pole
3-pole + Microswitch
3-pole + Neutral
3-pole + Neutral + Microswitch
4-pole
1-pole
2-pole
3-pole
1-pole
2-pole
3-pole
For further details see Data Sheets 2053 (CH08, CHM, CHCC, CH14 AND CH22) and 2144 (CHJ Class J)
*90V miminum required for illumination
***12V mininum required for illumination
UL Recognized (cURus)
8x32 IEC
1
2
1
2
3
1
1.5
1.5
1.5
3
3
4.5
4.5
6
6
6
2
2
2
4
4
6
6
8
8
8
22x58 IEC
Maximum torque
2.5 Nm (22LB-In)
2.0 Nm (17.5LB-In)
2.5 Nm (22LB-In)
3.4 Nm (30LB-In)
3.4 Nm (30LB-In)
3.0 Nm (26LB-In)
4.0 Nm (35LB-In)
Eaton.com/bussmannseries
9-5
Fuse holders
and blocks
Class J
Without indication
CH30J1
CH30J2
CH30J3
Size
CHM1DI-48U
CHPV1IU
CHPV2IU
CHCC1DIU
CHCC2DIU
CHCC3DIU
CHCC1DI-48U
Class J 30A
IEC
Specifications:
Wiring:
Packaging:
Installation technique:
Environmental data:
UL 508
cULus to CSA Standard 22.2 No.14
PLCprogramming:
De-energize all circuits before installing or removing any CH-PLC devices and follow all prescribed safety procedures.
9-6
1007July 2015
Eaton.com/bussmannseries
Specifications
Agency information: UL 508, File E195399
Pitch: 17.8mm
SCCR: 10kA (default)
100kA (with upstream Class J 200A fuses)
Max current: 100A (power feed from end;
Max voltage: 600Vac/dc (three phase)
1000Vdc/600Vac (single phase)
Features and benefits
Easily distribute power in single-phase or three-phase
configurations
Flexible cut-to-length solutions without compromising on the
products finger-safe features
100kA SCCR (Short-Circuit Current Rating) when protected
by a 200A Class J fuse
Single-phase bus bars rated to 1000Vdc and 100A in end-fed
configuration
Three-phase bus bars rated to 600Vac/dc and 100A in
end-fed configuration
Power feed terminals for single-phase and three-phase
service
Selection guide
Description
Single-phase 1000Vdc busbar, 100A, 3 pins, assembled endcap
Single-phase 1000Vdc busbar, 100A, 6 pins, assembled endcap
Single-phase 1000Vdc busbar, 100A, 9 pins, assembled endcap
Single-phase 1000Vdc busbar, 100A, 12 pins, assembled endcap
Single-phase 1000Vdc busbar, 100A, 15 pins, assembled endcap
Single-phase 1000Vdc cuttable busbar, 100A, 57 pins, without endcap
Three-phase 600V busbar, 100A, 6 pins, assembled endcap
Three-phase 600V busbar, 100A, 9 pins, assembled endcap
Three-phase 600V busbar, 100A, 12 pins, assembled endcap
Three-phase 600V busbar, 100A, 15 pins, assembled endcap
Three-phase 600V cuttable busbar, 100A, 57 pins, without endcap
Single-phase busbar endcap
Three-phase busbar endcap
35mm2 feeder terminal for three-phase busbar (115A, 1000Vac/dc)
Spare contact safety protection covers
Single-phase low-profile feeder terminal (115A, 1000Vac/dc)
50mm2 direct feed terminal (1000Vac/dc)
Fuse holders
and blocks
Part number
BB1P100M3
BB1P100M6
BB1P100M9
BB1P100M12
BB1P100M15
BB1P100M57
BB3P100M6
BB3P100M9
BB3P100M12
BB3P100M15
BB3P100M57
ECAP1P
ECAPMP
PWR35MM
FSCVR
PWR1PLP
PWR50MM
1007July 2015
Eaton.com/bussmannseries
9-7
ECAP1P
PWR35MM
Single-phase
ECAPMP
FSCVR
PWR50MM
1007July 2015
Eaton.com/bussmannseries
PWR1PLP
CH _ _ J _
Specifications
Description: IP20 finger-safe, 1- to 3-pole Class J fuse
holder with DIN-Rail or panel mounting.
Ratings:
Volts: 600Vac/dc (or less)
Amps: 30A (30A version)
60A (60A version)
SCCR: 200kA
Wire range: Cu solid and stranded conductors with single
(1-18AWG) and dual (3-18AWG) wire ratings. See catalog
numbers table for details.
Torque rating:10-18AWG 24 lb-in.
1-8AWG 35 lb-in.
Poles: 1-, 2- or 3-pole.
Storage and operating temperature range*:
-20C to 75C.
Agency information: CE, UL 4248/CSA 22.2 No. 4248.P
ULListed, Guide IZLT, File E14853.
Flammability rating: UL 94V0.
30A version
Catalog numbers
See catalog numbers table below.
Dimensions (mm):
Fuse size
0-30A
35-60A
Poles
1
2
3
1
2
3
60A version
32
64
96
40
80
120
70
70
70
83
83
83
115
115
115
125
125
125
*For fuse selection on applications above or below 25C, consult derating charts in
Eaton publication Selecting Protective Devices (SPD).
Catalog numbers
Catalog
# of
numbers poles
Local
indication
Amp
rating
Volts
IP20
AWG single
(AC/DC) finger-safe wire range
1
1
2
2
3
3
easyID**
Neon lamp***
easyID**
Neon lamp***
easyID**
Neon lamp***
30
600
Yes
CH60J1
CH60J1I
CH60J2
CH60J2I
CH60J3
CH60J3I
1
1
2
2
3
3
easyID**
Neon lamp***
easyID**
Neon lamp***
easyID**
Neon lamp***
60
600
Yes
Padlockable
Mounting
1-18
Yes
1-18
Yes
Fuse holders
and blocks
CH30J1
CH30J1I
CH30J2
CH30J2I
CH30J3
CH30J3I
** easyID viewing window, requires use of Bussmann series LPJ_SPI permanent indication fuses.
*** Indication non-fuse dependent, minimum voltage 90V.
1007July 2015
Eaton.com/bussmannseries
9-9
Features/benefits
Padlockable with finger-safe terminals for safety. Qualified
as IP20 per IEC 60529.
Cam-action handle for easy module removal, offered with
Class CC rejection clips or European 10 x 38mm clips to
meet global needs
Wire ready with 35mm DIN-Rail or screw panel mounting
(#8 screw, 114 long) saves installation time
Fuse indication lights with option for remote fuse status
available. See Data Sheet for additional wiring details.
OPM-1038(R)SW(C)
with disconnect switch
O P M -
1 0 3 8
Fuse type
S W
Blank = 10 x
38mm or 1332 x 1-12
R = Class CC
Typical applications
Industrial control
Process control systems
Automated warehouse systems
Communication
Individual control circuits
C=
Communication
feature
Dimensions
5.72 ( .045)
(145.3mm) ( 1.14)
4.25 ( 0.03)
(108.0mm) ( 0.76)
0.43 ( 0.03)
(10.9mm) ( 0.76)
3-Phase
Class CC
LP-CC
KTK-R
FNQ-R
Volts
HP
240
5
480
10
Midget (non-rejection)
BAF
KTK
KLM
FNM
FNQ
600
15
1L1
4T 2
BUSS
Specifications
Description: 3-pole load break modular fuse holder and
disconnect switch for 1332 x 112 (10 x 38mm) fuses.
Dimensions: See dimensions illustration.
Poles: 3
Agency information: CE, UL (see table), CSA Certified,
C22.2 No. 39, Class 6225-01, File 47235, IEC (see table).
Flammability rating: UL 94V0.
Horsepower rating of switch
1.38
(35.0mm)
2T1
6T3
Communication
Port
3L2
1.76
0.27 (6.9mm) (44.7mm)
5L3
0.74 (18.8mm)
0.31 (7.9mm)
0.57 ( 0.03)
(14.5mm) ( 0.76)
3.74 ( 0.03)
(95.0mm) ( 0.76)
Communication
Port
3.17
(80.5mm)
0.23
(5.8mm)
0.50 (12.7mm)
0.44 (11.2mm)
0.224
(5.6mm)
1.86
(47.2mm)
Panel Mounting
Hole Pattern
3.60
(91.4mm)
1.312
( 0.01)
(33.3mm)
( 0.25)
Panel Mounting
Hole Pattern
European
C10M
C10G
Physical characteristics
Small size matches 45mm IEC starter width
Accepts #8-18 AWG stranded, #10-18 AWG solid wire
3-pole
Handle and shaft required for through the door operation
Catalog numbers
Catalog
numbers
OPM-1038SW
OPM-1038RSW
OPM-1038SWC
OPM-1038RSWC
Electrical rating
30A, 600Vac UL/CSA
SCCR**
rating
*
100kA
*
100kA
Clips
Non-rejection,
10x38mm or
13
32 x 1 12
Rejection,
Class CC
Non-rejection,
10x38mm or
13
32 x 1 12
Rejection,
Class CC
Remote open
fuse indication
No
No
Yes
Yes
UL information
std.
Recognized
UL 508
Listed
UL 508
Recognized
UL 508
Listed
UL 508
*Rating varies depending on fuse used in module; 10kA default, higher SCCR requires testing and certification.
**Short-Circuit Current Rating
File
Guide
IEC
CE
E161278
E161278
NLRV2
NLRV
IEC 60947-3
Yes
E161278
NLRV2
IEC 60947-3
E161278
1007July 2015
Eaton.com/bussmannseries
NLRV
Yes
No
No
Features/benefits
Padlockable with finger-safe terminals for safety. Qualified
as IP20 per IEC 529.
Cam-action handle for easy module removal.
Offered with Class CC rejection clips or European 10 x
38mm clips to meet global needs
Wire ready with 35mm DIN-Rail or screw panel mounting
(#8 screw, 1 14 long) saves installation time
Fuse indication lights with option for remote fuse status
indication. See Data Sheet for additional wiring details.
OPM-1038
Fuse type
O P M -
Blank = 10 x
38mm or
13
32 x 1 12
R = Class CC
Typical applications
Industrial control
Communication Process control systems
Automated warehouse systems
Individual control circuits
Dimensions
C=
Communication
feature
Midget (non-rejection)
BAF
KTK
KLM
FNM
FNQ
European
C10M
C10G
Catalog numbers
OPM-1038R
OPM-1038C
OPM-1038RC
Electrical rating
30A, 600Vac/dc UL/CSA
(Max 3 Watts per fuse)
32A, 660V IEC
30A, 600Vac/dc UL/CSA
30A, 600Vac/dc UL/CSA
(Max 3 Watts per fuse)
32A, 660V IEC
30A, 600Vac/dc UL/CSA
SCCR**
rating
*
200kA
*
200kA
IL1
Clips
Non-rejection,
10 x 38mm or
13
32 x 1 12
Rejection,
Class CC
Non-rejection,
10 x 38mm or
13
32 x 1 12
Rejection,
Class CC
Communication
Port
3L2
0.27 (6.9mm)
5L3
0.74 (18.8mm)
0.31 (7.9mm)
3.60 ( 0.03)
(91.4mm) ( 0.76)
0.57
(14.5mm)
3.74 ( 0.03)
(95.0mm)
( 0.76)
3.17
(80.5mm)
Communication
Port
1.65 ( 0.03)
(41.9mm) ( 0.76)
0.23
(5.8mm)
0.50 (12.7mm)
0.44 (11.2mm)
Physical characteristics
Small size matches 45mm IEC starter width
Accepts #8-18 AWG stranded, #10-18 AWG solid wire
3-pole
Catalog
numbers
OPM-1038
4T2
1.76 ( 0.03)
(44.7mm) ( 0.7 )
6T3
BUSS
Specifications
Description: 3-pole modular fuse holder for 1332 x 1 12
(10 x 38mm) fuses.
Dimensions: See dimensions illustration.
Poles: 3
Agency information: CE, UL (see table), CSA Certified,
C22.2 No. 4248, Class 6225-01, File 47235, IEC (see table).
Flammability rating: UL 94V0.
Recommended fuse types
Class CC
LP-CC
KTK-R
FNQ-R
3.22 ( 0.03)
(81.8mm) ( 0.76)
2T1
0.224"
(5.6mm)
Remote open
fuse indication
No
No
Yes
Yes
*Rating varies depending on fuse used in module; 10kA default, higher SCCR requires testing and certification.
**Short-Circuit Current Rating
1.312
( 0.01)
(33.3mm)
( 0.25)
Panel Mount
Hole Pattern
UL information
std.
Recognized
UL 4248
Listed
UL 4248
Recognized
UL 4248
Listed
UL 4248
3.60 ( 0.03)
(91.4mm) ( 0.76)
1.86 ( 0.03)
(47.2mm)
( 0.76)
Panel Mount
Hole Pattern
File
E14853
Guide
IZLT2
E14853
IZLT
E14853
IZLT2
E14853
IZLT
IEC
IEC 60269-2-1
IEC 60269-2-1
CE
Yes
Yes
No
No
Fuse holders
and blocks
1007July 2015
Eaton.com/bussmannseries
9-11
OPM-NG-
75
Cu only [mm2]
AWu
(Nm)/lb-in
AWG
[mm2]
(Nm)/lb-in
#18-8
x
1
1-6
x
1
18-12
Single/Dual
#18-8 x 1
1-6 x 1
18-12 Single/dual
#18-8#18-8
x 2 x 21-6 1-6
x 2 x 2Strld
15lb-in (1.7#18-8
Nm) x 1
#18-8 x 1
1-6 x 1
10-8
Single/Dual
#18-8#18-8
x 2 x 21-6 1-6
x 2 x 2 10-8
Single/dual
1-4 1-4
x 1 x 1 20lb-in
(2.5
Nm)
20in-lb
(2.5
Nm)
1-4 1-4
x 2x 2
Solid
Solid
1-6
x1
Stranded
Specifications
Description:
OPM-NG-SC3: 3-pole Class CC fuse holder for use with
Class CC fuses (Bussmann series LP-CC,
FNQ-R, KTK-R).
OPM-NG-SM3: 3-pole fuse holder for use with 1332 x 112 and
10.3 x 38mm fuses (Bussmann series
types: 1332 x 112; KTK, FNQ, KLM, FNM,
BAF, 10 x 38mm; FWA, FWC, C10G__,
C10M_ _).
Ratings:
Volts: OPM-NG-SC3: 600Vac (or less)
OPM-NG-SM3: 600Vac (or less) UL and CSA 30A
OPM-NG-SM3: 690Vac (or less) IEC 32A
Amps: OPM-NG-SC3: 0-30A
OPM-NG-SM3: 0-30A
SCCR: OPM-NG-SC3: 200kA
OPM-NG-SM3: Same as fuse IR, 200kA maximum.
Agency information: CE, UL; OPM-NG-SC3 UL Listed, UL
4248, File E14853, Guide IZLT. OPM-NG-SM3, UL
Recognized, UL 4248, File E14853, Guide IZLT2. CSA
Certified, C22.2 No. 4248, Class 6225-01, File 47235. IEC
60947-3 Utilization Category AC20B.
Handling and storage temperature: -10 to 65C.
Features/benefits
45mm width matches IEC starters
35mm DIN-Rail or panel mounting feature. Maximum screw
size #8 (M4)
Pressure plate terminations with dual-wire rated terminals
(see wire table) and optional auxiliary contacts
Integrated collapsible handle and fuse carrier cannot be
removed from holder base
Padlockable and IP20 finger-safe to IEC60529
Typical applications
Mass produced control systems
Process control systems
Automated warehouse systems
Individual control circuits
Ferrules
Ferrules
Wiring
Solid
conductor
Stranded
conductor
Connector
screw clamp
Tightening
torque:
to
to
to
to
25mm2)
10mm2)
25mm2)
10mm2)
conductor or
conductors
conductor or
conductors
Materials:
Housing: Thermoplastic - ULV2
Clip: Tin-plated copper alloy
Contact lubricant: Fluoroether grease
Saddle screw: Plated steel
DIN-Rail springs: Stainless steel
Optional accessories:
Comb bar (max current rating = 63A)
Catalog number
GV2G245A46
GV2G254A46
GV2G272A46
GV2G345A46
GV2G354A46
GV2G445A46
GV2G454A46
GV2G472A46
GV2G554A46
Description
2 circuit, 45mm between same phases
2 circuit, 54mm between same phases
2 circuit, 72mm between same phases
3 circuit, 45mm between same phases
3 circuit, 54mm between same phases
4 circuit, 45mm between same phases
4 circuit, 54mm between same phases
4 circuit, 72mm between same phases
5 circuit, 54mm between same phases
Description
Input/feed through power terminal, supports feed
through to another system, DIN-Rail mount only
Input power terminal
Cover
Catalog number
GV1G10
Description
Protective cover for unused terminals on comb bar
Auxiliary contacts
Catalog number
GVAE11
GVAE20
Description
NO/NC
NO/NO
9-12
1007July 2015
Eaton.com/bussmannseries
Optional accessories
Fuse holders
and blocks
1007July 2015
Eaton.com/bussmannseries
9-13
30A version
(Note: For JT(N)60030 use both stranded or solid, in a variety of dual wire combinations of same
wire size and type.)
Typical applications
Industrial controls
Process controls
Small HP VFDs
Catalog numbers
JT60030
JT60060
JTN60030
JTN60060
Amps
30
60
30
60
Catalog numbers
Indication
Non-indicating
Non-indicating
Indicating (neon)
Indicating (neon)
1007July 2015
Eaton.com/bussmannseries
60A version
1.14
(29.0)
1.05
(26.7)
Slot
Din-rail
BUSS
BUSS
BUSS
JT60030
0 30A
600VAC
JT60030
0 30A
600VAC
JT60030
0 30A
600VAC
DO NOT REMOVE
UNDER LOAD
DO NOT REMOVE
UNDER LOAD
DO NOT REMOVE
UNDER LOAD
USE CLASS J
FUSES
.07
(1.8)
2.75
(69.9)
MOUNTING
Shown without fuse
pullout cover
1 pole
2 pole
1.23
(31.2)
3 pole
USE CLASS J
FUSES
2.42
(61.3)
USE CLASS J
FUSES
3.60
(91.4)
2.52
(64.1)
1.31
(33.3)
1.25
(31.8)
Slot
Din-rail
BUSS
BUSS
BUSS
JT60060
35 60A
600VAC
JT60060
35 60A
600VAC
JT60060
35 60A
600VAC
DO NOT REMOVE
UNDER LOAD
DO NOT REMOVE
UNDER LOAD
DO NOT REMOVE
UNDER LOAD
USE CLASS J
FUSES
.10
(2.6)
3.10
(78.7)
1 pole
2 pole
3 pole
MOUNTING
1.52
(38.1)
USE CLASS J
FUSES
2.96
(75.2)
USE CLASS J
FUSES
4.40
(111.7)
3.06
(77.7)
JT(N)600 series fuse blocks can be dovetailed together within the same current rating to provide multiple pole block
configurations.
NOTE: JT(N)60030 cannot be dovetailed to JT(N)60060.
Fuse holders
and blocks
1007July 2015
Eaton.com/bussmannseries
9-15
SAMI-1I
SAMI-2I
SAMI-3I
SAMI-6I
Specifications
Description: Indicating and non-indicating fuse covers for
Class J, RK1, RK5, H, K5, CC, G (0-30A) and midget-type
fuses. Indicating feature requires a minimum of 90V to
illuminate lamp. One cover required for each pole.
WARNING: To avoid electrical shock, turn power off before
installing, removing or servicing.
Dimensions: See dimensions illustration.
Agency information: CE, UL Listed; SAMI-1I through
SAMI-6I, SAMI-8I and SAMI-9I, SAMI-1N through SAMI-6N,
SAMI-8N and SAMI-9N, UL Recognized; Guide JDVS2, File
E58836, SAMI-7I and SAMI-7N, CSA Certified,
File LR47235-93C.
TEST PROBE
FUSE
Data Sheet: 1204 (Trimming guides: 12041, 12042, 12043, 12044, 12045, 12046, 12048, 12049)
BUSSMANN SERIES FULL LINE CATALOG
1007July 2015
Eaton.com/bussmannseries
LINE
TEST PROBE
Buss
SAMI -2
Dimensions - in
Description
A
B
C
600V, J (0-30A) and 600V, T (35-60A)** 5.02
1.03
1.94
250V, RK, K5, H (35-60A)
600V, RK, K5, H (0-30A)
7.03
1.30
2.07
600V, J (65-100A)
7.03
1.30
2.33
250V, RK, K5, H (65-100A)
8.20
1.30
2.18
600V, RK, K5, H (35-60A)
8.20
1.30
2.18
600V, J (35-60A)
4.98
1.17
2.14
600V, Midget, Class CC, G (0-30A)
3.82
0.75
1.72
600V, RK, K5, H (65-100A)
10.38
1.50
2.33
250V, RK, K5, H (0-30A) and 600V,
3.82
0.75
1.72
T (0-30A)
Dimensions
*For indicating cover, add suffix I, for non-indicating cover, add suffix N.
Example: SAMI-7I = Indicating, SAMI-7N = Non-indicating.
**Available in non-indicating only.
SAMI-8A adapter available for small Fusetron body design. SAMI-8I and SAMI-8N come
standard with adapter (SAMI-8A).
Not for use with KTS-R fuses.
9-16
SAMI-8I
Typical applications
Class H, R and J fuse blocks up to 100A
Class T fuse blocks up to 60A
Class CC, G and Midget, 30A fuse blocks
LOAD
SAMI-2_
SAMI-3_
SAMI-4_
SAMI-5_
SAMI-6_
SAMI-7_
SAMI-8_
SAMI-9_
SAMI-7I
Catalog numbers
Catalog
numbers*
SAMI-1_
SAMI-4I
Ratings:
Volts: 250V, 600V
Amps: 70-600A
SCCR: 200kA (Class R and J)
10kA (Class H and K)
Agency information:
Flammability ratings:
Blocks: UL 94V0, self-extinguishing
Covers: UL 94HB, self-extinguishing
Operating and storage temperature range:
Blocks -40C to 120C
Covers non-indicating covers -40C to 120C
indicating covers -20C to 90C
Materials:
Base Thermoplastic
Box Lug Tin-plated aluminum
Wire:*
Cu/Al 75C/90C (100 - 200A)
Cu/Al 75C only (400 - 600A)
*Higher temperature rated wire can be used with appropriate derating.
Fuse holders
and blocks
1007July 2015
Eaton.com/bussmannseries
9-17
250V Class
R and H(K)
2
Catalog number
Class H(K)
Class R
HM25100-1CR
RM25100-1CR
HM25100-2CR
RM25100-2CR
Covers*
w/o indication
w/ indication
Volts
CVRI-RH-25100
100
6.2 (55)
5.6 (50)
8 AWG
5.1 (45)
NON, CDN,
4.5 (40)
PON
4.0 (35)
3/0-1 AWG
42 (375)
2-6 AWG
31 (275)
HM25200-1CR
RM25200-1CR
HM25200-2CR
RM25200-2CR
HM25200-3CR
RM25200-3CR
HM25400-1CR
110-
200
250
RM25400-1CR
1
225-
RM25400-2CR
HM25400-3CR
RM25400-3CR
HM25600-1CR
RM25600-1CR
HM25600-2CR
RM25600-2CR
HM25600-3CR
RM25600-3CR
HM60100-1CR
RM60100-1CR
HM60100-3CR
RM60100-2CR
400
450CVR-RH-25600
CVR-RH-60100
CVRI-RH-25600
600
70100
CVRI-RH-60100
RM60100-3CR
HM60200-1CR
RM60200-1CR
HM60200-2CR
RM60200-2CR
HM60200-3CR
RM60200-3CR
HM60400-1CR
RM60400-1CR
HM60400-2CR
CVRI-RH-25400
HM25400-2CR
HM60100-2CR
CVR-RH-25400
RM60400-2CR
3
1
110CVR-RH-60200
CVRI-RH-60200
200
600
1
CVR-RH-60400
CVRI-RH-60400
400
HM60400-3CR
RM60400-3CR
HM60600-1CR
RM60600-1CR
HM60600-2CR
RM60600-2CR
HM60600-3CR
RM60600-3CR
Catalog number
Class J
450CVR-RH-60600
w/o indication
CVRI-RH-60600
Covers*
w/ indication
Volts
1
CVR-J-60100-M
70-
CVRI-J-60100-M
JM60100-3CR
2
3
JM60200-1CR
110CVR-J-60200-M
CVRI-J-60200-M
200
JM60200-3CR
LPN-RK_SPI**
FRN-R
500kcmil-4 AWG
51 (450)
KTN-R
N/A
57 (500)
34 (300)
N/A
51 (450)
1-3 AWG
4-6 AWG
6.2 (55)
5.6 (50)
8 AWG
5.1 (45)
NOS,
4.5 (40)
CDS
4.0 (35)
3/0-1 AWG
42 (375)
2-6 AWG
31 (275)
600
1
2
1
JM60400-2CR
2
CVR-J-60400-M
CVRI-J-60400-M
225-400
JM60400-1MW22
JM60400-2MW22
JM60400-3MW22
LPS-RK_SP
LPS-RK_SPI**
FRS-R
500kcmil-4 AWG
51 (450)
KTS-R
57 (500)
KWS-R
34 (300)
PVS-R
N/A
N/A
51 (450)
Wire range
(fine stranded)
Torque
Nm (Lb-In)
1-3 AWG
6.2 (55)
4-6 AWG
5.6 (50)
8 AWG
5.1 (45)
4.5 (40)
4.0 (35)
3/0-1 AWG
42 (375)
2-6 AWG
31 (275)
JM60600-1CR
450CVRI-J-60600
JM60600-3CR
600
Bussmann
series fuses
LPJ_SP
LPJ_SPI**
600kcmil
57 (500)
JKS
500kcmil-4 AWG
51 (450)
DFJ
57 (500)
1
2
42 (375)
51 (275)
3
CVR-J-60600
Class R:
57 (500)
JM60600-2CR
Class H(K):
600kcmil
JM60400-1CR
JM60400-3CR
LPN-RK_SP
57 (500)
Fuse range
Wire
range optional cover provides IP20
For Class J Number
400A double box lug
configuration,
wires or one single 350kcmil-6 AWG wire.
(amps)350kcmil-300kcmil
of poles
(solid and stranded)***
100
JM60200-2CR
Class R:
JM60100-1CR
JM60100-2CR
600
Class H(K):
600kcmil
3
225-
Bussmann
1-3 AWG
4-6 AWG
RM25100-3CR
CVRI-RH-25200
Torque
HM25100-3CR
CVR-RH-25200
Wire range
1
70CVR-RH-25100
Class J
N/A
34 (300)
1
2
N/A
51 (450)
*Covers sold serarately. Blown fuse indication requires 90 volts minimum and closed circuit to operate.
***Ratings for copper and aluminum wire except where otherwise noted.
**With easyID blown fuse indication.
For Class J 400A double box lug configuration, optional cover provides IP20 finger-safe protection for dual 350kcmil-300kcmil wires or one single 350kcmil-6 AWG wire.
9-18
1007July 2015
Eaton.com/bussmannseries
Dimensions - mm (in)
70-100A
110-200A
225-400A
450-600A
Fuse holders
and blocks
1007July 2015
Eaton.com/bussmannseries
9-19
Dimensions - mm (in)
70-100A
110-200A
225-400A
450-600A
9-20
1007July 2015
Eaton.com/bussmannseries
Dimensions - mm (in)
70-100A
110-200A
225-400A
450-600A
Fuse holders
and blocks
1007July 2015
Eaton.com/bussmannseries
9-21
Class J
Wire:
75C CU/AL*
Specifications
* Conductors with higher temperature rating may be used, but at their 75C ampacity.
Description:
New Class J fuse block features
power distribution capability.This
patented design simplifies your
panel layout and uses up to 50%
less panel space. Additionally, it
lowers inventory costs while
reducing installation time and
labor by 33%.
Accessories:
High Speed Class J DFJ Drive Fuses (see Data Sheet # 1048)
Fuse Class:
Class J
Ratings:
Volts
- 600V
Amps
- 70-400A
Withstand - 200kA Sym RMS
Agency information:
Loadside view
Poles:
Base:
- Thermoplastic
4.0 (35)
2.8 (25)
8
1
4.0 (35)
2.8 (25)
8
1
31 (275)
4.5 (40)
8
1
4.0 (35)
2.8 (25)
(
31 (275)
4.5 (40)
(
31 (275)
8
1
4.0 (35)
2.8 (25)
4.5 (40)
1007July 2015
Eaton.com/bussmannseries
31 (275)
(
4.5 (40)
Lineside
Part
Optional
Volts
Fuse
Number
Covers
(V)
Range
JM60100-1MW14
JM60100-2MW14
JM60100-3MW14
JM60200-1MW16
JM60200-2MW16
JM60200-3MW16
CVR-J-60100-M
CVRI-J-60100-M*
CVR-J-60200-M
CVRI-J-60200-M*
600
600
Torque
Poles
100A
1/0-1;
4-6;
8;
10-14;
5.6 (50)
5.0 (45)
4.5 (40)
4.0 (35)
250kcmil-1;
(2) 2-6;
42 (375)
31 (275)
110-
200A
1
2
JM60400-2MW16
JM60400-3MW16
600kcmil-4;
500kcmil;
(2) 3/0-4;
600
Conductors
Torque
AWG; Nm (Lb-In)
70-
JM60400-1MW16
CVR-J-60400-M
CVRI-J-60400-M*
Loadside
Conductors
AWG; Nm (Lb-In)
57 (500)
51 (450)
57 (500) CU
34 (300) AL
1
2
3
JM60400-2MW26
JM60400-3MW26
(2) 350kcmil-1;
(2) 2-6;
10-14;
(2) 10-14;
2.3 (20)
3.4 (30)
4-6;
4.0 (35)
8;
2.8 (25)
(12)**10-14 CU
10-14;
2.3 (20)
(2) 10-14;
3.4 (30)
2-3;
5.6 (50)
4-6;
8;
5.0 (45)
4.5 (40)
(2) 8;
4.5 (40)
10-14;
4.0 (35)
(2) 10-14; 4.5 (40)
(12)**8-14 CU, 8 AL
42 (375)
31 (275)
4.0 (35)
2.8 (25)
225400A
JM60400-1MW26
4-6;
8;
2-3;
4-6;
8;
(2) 8;
5.6 (50)
5.0 (45)
4.5 (40)
4.5 (40)
10-14;
4.0 (35)
* With open fuse indication. 90V minimum and closed circuit required for illumination.
** Dual wire rated lugs with same wire size.
Copper conductor only.
Lineside dual box lug.
Dual wire not for CSA installations
Dimensions - in (mm)
J
A
100A Block
Mounting Holes
N
O
N
O
L
J
Block Size
100A
200A
400A
in
2.0
4.0
6.0
5.5
5.5
2.8
2.2
6.0
2.8
0.9
2.0
0.4
1.1
0.4
0.5
mm
51
102
153
139
139
72
55
152
72
22
51
10
29
13
in
2.6
5.3
8.0
6.8
6.8
3.8
3.0
7.3
3.8
1.4
2.6
0.3
1.3
0.4
0.7
mm
67
134
203
172
172
97
75
186
97
35
67
32
19
in
3.5
7.0
10.6
8.0
8.0
4.8
4.1
8.7
4.8
2.0
3.5
0.3
1.6
0.4
0.7
mm
88
177
268
202
202
121
105
220
121
50
88
41
19
Fuse holders
and blocks
1007July 2015
Eaton.com/bussmannseries
9-23
Class H(K), J and R modular ferrule fuse blocks 250 and 600V
Flammability ratings:
Specifications
Description: HM Class H(K)
JM Class J and RM Class R
modular ferrule fuse blocks for
fuses up to 60 amps.
Volts
Amps
up to 60A
Blocks
Indicating covers
Base Thermoplastic
Covers Thermoplastic
Blocks:
UL Listed E14853 - IZLT
CE
RoHS Compliant
Covers:
RoHS Compliant
-20C to +90C*
Materials:
Agency information:
-40C to +120C
Ratings:
Poles:
F
Table 1. Terminals, conductors and torque values
Torque
Terminal type
Box Lug (CR Option)
All other terminals*
AWG type/range
AWG
Lb-in (Nm)
2-3;
4-6;
8;
10-14;
50
45
40
35
75/90C CU 10-18
10-18;
20 (2.3)
* 3/16 Quick Connect terminal maximum ampacity dependent on female spade connector and wire ratings.
1007July 2015
Eaton.com/bussmannseries
(5.6)
(5.1)
(4.5)
(4.0)
Class H(K), J and R modular ferrule fuse blocks 250 and 600V
Pressure plate
HM25030-1CR
HM25030-1SR
HM25030-1QR
HM25030-1PR
HM25030-2CR
HM25030-2SR
HM25030-2QR
HM25030-2PR
HM25030-3CR
HM25030-3SR
HM25030-3QR
HM25030-3PR
HM25060-1CR
HM25060-2CR
HM25060-3CR
HM60030-1CR
HM60030-1SR
HM60030-1PR
HM60030-2CR
HM60030-2SR
HM60030-2PR
HM60030-3CR
HM60030-3SR
HM60030-3PR
HM60060-1CR
HM60060-2CR
HM60060-3CR
Volts
Poles
1
1/2 to 30
2
3
250
1
31 to 60
2
3
1
1/2 to 30
2
3
600
1
31 to 60
2
3
* 3/16 Quick Connect terminal maximum ampacity dependent on female spade connector and wire ratings.
Volts
Amp range
Indicating
1/2 to 30
CVRI-RH-25030
CVR-RH-25030
31 to 60
CVRI-RH-25060
CVR-RH-25060
250
600
Non-indicating
1/2 to 30
CVRI-RH-60030
CVR-RH-60030
31 to 60
CVRI-RH-60060
CVR-RH-60060
# = number of poles
XX = terminal type
Pressure plate
RM25030-1CR
RM25030-1SR
RM25030-1QR
RM25030-1PR
RM25030-2CR
RM25030-2SR
RM25030-2QR
RM25030-2PR
RM25030-3CR
RM25030-3SR
RM25030-3QR
RM25030-3PR
RM25060-1CR
RM25060-2CR
RM25060-3CR
RM60030-1CR
RM60030-1SR
RM60030-1PR
RM60030-2CR
RM60030-2SR
RM60030-2PR
RM60030-3CR
RM60030-3SR
RM60030-3PR
RM60060-1CR
RM60060-2CR
RM60060-3CR
Volts
Poles
1
1/2 to 30
2
3
250
1
31 to 60
2
3
1
1/2 to 30
2
3
600
1
31 to 60
2
3
* 3/16 Quick Connect terminal maximum ampacity dependent on female spade connector and wire ratings.
Volts
250
600
Amp range
Indicating
1/2 to 30
CVRI-RH-25030
Non-indicating
CVR-RH-25030
31 to 60
CVRI-RH-25060
CVR-RH-25060
1/2 to 30
CVRI-RH-60030
CVR-RH-60030
31 to 60
CVRI-RH-60060
CVR-RH-60060
Fuse holders
and blocks
# = number of poles
XX = terminal type
1007July 2015
Eaton.com/bussmannseries
9-25
Class H(K), J and R modular ferrule fuse blocks 250 and 600V
36
1.4
50
2.0
26
1.0
75
2.9
R3
.1
99
3.9
5
.2
80
3.2
50
2.0
25
1.0
51
2.0
45
1.8
13
.5
49
1.9
74
2.9
15
.6
25
1.0
With cover.
See table 5 for available covers
108
4.2
7
.3
4
.2
3
.1
35
1.4
32
1.2
6
.2
69
2.7
34
1.3
68
2.7
103
4.1
135
5.3
102
4.0
47
1.8
With cover.
See table 5 for
available covers
58
2.3
34
1.3
19
.7
1007July 2015
Eaton.com/bussmannseries
88 3.5
59
2.3
7 .28
4 .16
183
7.2
80
3.13
31
1.2
2 .08
2 .08
90 3.5
60
2.4
29
1.2
16
.61
58
2.3
With cover.
See table 5 for available covers
7
.3
8
.3
3
.1
5
.2
39
1.6
77
3.0
38
1.5
54
2.1
82
3.2
77
3.0
66
2.6
116
4.6
115
4.5
With cover.
See table 5 for
available covers
17
.7
38
1.5
Fuse holders
and blocks
1007July 2015
Eaton.com/bussmannseries
9-27
Class H(K), J and R modular ferrule fuse blocks 250 and 600V
Pressure plate
JM60030-1CR
JM60030-1SR
JM60030-1PR
JM60030-2CR
JM60030-2SR
JM60030-2PR
JM60030-3CR
JM60030-3SR
JM60030-3PR
JM60060-1CR
JM60060-2CR
JM60060-3CR
Volts
1
1/2 to 30
1
31 to 60
JM60030-#XX
600
JM60060-#XX
Amp range
Indicating
Non-indicating
1/2 to 30
CVRI-J-60030
CVR-J-60030
31 to 60
CVRI-J-60060
CVR-J-60060
# = number of poles
XX = terminal type
2
3
Catalog numbers
Volts
2
3
600
Poles
1007July 2015
Eaton.com/bussmannseries
Class H(K), J and R modular ferrule fuse blocks 250 and 600V
28
1.1
87
3.4
110
4.3
83
3.3
56
2.2
84
3.3
R3
.1
12
.5
28
1.1
29
1.1
46
1.8
55
2.2
17
.7
58
2.3
With cover.
See table 5 for available covers.
Class J - 60A block dimensions - mm (in)
119
4.7
R3
.1
7
.3
94
3.7
5
.2
18
.7
38
1.5
38
1.5
53
2.1
18
.7
114
4.5
77
3.0
39
1.5
113
4.5
75
3.0
65
2.6
With cover.
See table 5 for available covers.
Fuse holders
and blocks
1007July 2015
Eaton.com/bussmannseries
9-29
Class H(K), J and R modular ferrule fuse blocks 250 and 600V
Installing/removing covers
Place one edge of DIN-Rail in fuse block base, then rotate block down until it clicks into place.
1007July 2015
Eaton.com/bussmannseries
JP
Specifications
Description: Pyramid style 3-pole fuse block for use with
Class J fuses (Bussmann series LPJ, DFJ, JKS).
Dimensions: See dimensions illustrations.
Ratings:
Volts: 600V
Amps: 0-30A
SCCR: 200kA RMS Sym.
Agency information: CE, UL Listed, UL 4248, Guide IZLT,
File E14853, CSA Certified, C22.2 No. 39, Class 4225-04,
File 47235.
Flammability rating: UL 94V0.
Mounting: Panel or 35mm DIN-Rail mount.
To order DIN-Rail: Part# DRL35MMLO (1 meter).
Catalog numbers
Mounting
With
Screws
DINwith
Catalog
Rail
pressure
numbers
Panel adapter* plate
Aluminum
JP60030-3PR
X
X
JP60030-3CR
X
X
JP60030-3COR
X
JP60030-3PRA
X
X
JP60030-3CRA
X
X
JP60030-3CORA
X
*Adapter only for DIN-Rail - Cat No. JPA-3.
Box
Copper
only
X
X
Wire range
#10-14 Cu Only
#2-14 Cu/Al
#2-14 Cu Only
#10-14 Cu Only
#2-14 Cu/Al
#2-14 Cu Only
4.00" MAX.
(101.6mm)
2.78"
(70.6mm)
3.06"
(77.8mm)
3.75" (0.02)
(95.3mm (0.50)
3.13"
(79.5mm)
1.88"
(47.6mm)
1.19"
(30.2mm)
ADAPTOR
FOR 35mm
SYMMETRICAL
DIN-RAIL
MOUNTING
2.38"
(60.4mm)
3.29"
(83.6mm)
Fuse holders
and blocks
Data Sheet:1108
BUSSMANN SERIES FULL LINE CATALOG
1007July 2015
Eaton.com/bussmannseries
9-31
Flammability ratings:
Specifications
Description: BCM (Class CC) and
BMM (supplemental 13/32 x
1-1/2 /10x38) modular style fuse
blocks with optional covers.
These new Bussmann series fuse
blocks contain multiple features to
add versatility, reduce labor and
enhance safety of any panel design.
Blocks
Indicating covers
-40C to +120C
-20C to +90C*
Ratings:
Materials:
Volts
600V
Amps
up to 30A
Agency information:
Class CC BCM Series
CE
RoHS Compliant
Base Thermoplastic
Covers Thermoplastic
CE
RoHS Compliant
Covers:
IP20 finger-safe
RoHS Compliant
P
Poles:
Flammability ratings:
Table 1. Catalog numbers
Terminal type
#10-32
Phil-slot screw
Screw with
quick connect*
BCM603-1S
BCM603-1SQ
BCM603-1P
BCM603-1PQ
BCM603-1C
CC
BCM603-2S
BCM603-2SQ
BCM603-2P
BCM603-2PQ
BCM603-2C
CC
BCM603-3S
BCM603-3SQ
BCM603-3P
BCM603-3PQ
BCM603-3C
CC
Poles
BMM603-1SQ
BMM603-1PQ
BMM603-1C
10x38 (13/32x1-1/2)
BMM603-2SQ
BMM603-2PQ
BMM603-2C
10x38 (13/32x1-1/2)
BMM603-3SQ
BMM603-3PQ
BMM603-3C
10x38 (13/32x1-1/2)
BCCMM603-3SQ
BCCMM603-3PQ
* Quick Connect terminal maximum ampacity dependent on female spade connector and wire ratings.
9-32
Fuse class
1007July 2015
Eaton.com/bussmannseries
Dimensions - mm (in)
33
1.3
40
1.6
21
.8
95
3.7
77 10
3.0 .4
4
.2
20
.8
16
.6
41
1.6
60
2.4
20
.8
39
1.6
59
2.3
33
1.3
With cover.
See Table 3 for available covers.
Terminal type
75/90C
AWG type/
range
Torque
AWG
lb-in (Nm)
CU 2-14
AL 2-8
CU 2-3
CU 4-6
CU 8-14
AL 2-6
AL 8
CU 10-18
10-18
50
45
35
50
40
(5.6)
(5.1)
(4.0)
(5.6)
(4.5)
Screw (S)
Screw/quick connect* (SQ)
Pressure plate (P)
20 (2.3)
BMM603-3Cwith
with
BMM603-3C
CVRI-CCMcovers
coversand
and
CVRI-CCM
TM26CBmarker
markerlabels
labels
TM26CB
Pressure plate/
quick connect* (PQ)
* Quick Connect terminal maximum ampacity dependent on female spade connector
and wire ratings.
Indicating
Non indicating
CVRI-CCM
CVR-CCM
Screw (S)
CVRI-CCM
CVR-CCM
CVRI-CCM-QC
CVR-CCM-QC
CVRI-CCM
CVR-CCM
CVRI-CCM-QC
CVR-CCM-QC
Fuse holders
and blocks
1007July 2015
Eaton.com/bussmannseries
9-33
BPVM
Specifications
Description: BPVM modular style
1000Vdc fuse blocks for use with
10x38mm (13/32 x 1-1/2)
photovoltaic fuses up to 30 amps.
These new Bussmann series fuse
blocks contain multiple features to
add versatility, reduce labor and
enhance safety of any panel design.
Blocks
Indicating covers
Ratings:
Volts
-40C to +120C
-20C to +90C*
Materials:
Base Thermoplastic
Covers Thermoplastic
1000Vdc
up to 30A
Marker labels:
Amps
Withstand 33kA
Agency information:
R
Features
and benefits:
Blocks:
CE
RoHS Compliant
Covers:
IP20 finger-safe
RoHS Compliant
Poles:
Flammability ratings:
1007July 2015
Eaton.com/bussmannseries
Terminal type
AWG
CU 2-14, AL 2-8
CU 2-3
CU 4-6
CU 8-14
AL 2-6
AL 8
CU 10-18
10-18
Screw (S)
lb-in (Nm)
50
45
35
50
40
(5.6)
(5.1)
(4.0)
(5.6)
(4.5)
20 (2.3)
Box lug
Poles
BPVM-1S
BPVM-1C
Fuse class
10x38 (13/32# x 1-1/2) gPV and PV
BPVM-2S
BPVM-2C
Non indicating
CVRI-CCM
CVR-CCM
Dimensions - mm (in)
33
1.3
21
.8
40
1.6
77 10
3.0 .4
95
3.7
4
.2
20
.8
41
1.6
16
.6
20
.8
39
1.5
33
1.3
With cover.
See Table 3 for available covers.
Fuse holders
and blocks
1007July 2015
Eaton.com/bussmannseries
9-35
T300
Specifications
Description: T300 (300V) fuse blocks for use with Class T
fuses (Bussmann series JJN).
Dimensions: See dimensions illustrations.
Poles: 1 to 4
Ratings:
Volts: 300Vac/dc
Amps: 12 - 600A
SCCR: 200kA RMS Sym.
Agency information: CE, UL Listed UL 4248, Guide IZLT,
File E14853, CSA Certified, Class 6225-01, File 47235.
Flammability rating: UL 94V0.
T30100-1CR
T30030-2CR
T30600-1C
Typical applications
300Vac/dc or less control systems
300Vac/dc or less individual control circuits
Catalog numbers
Screw
T30030-2SR
T30030-3SR
T30030-4SR
T30060-2SR
T30060-3SR
T30060-4SR
Box Lug
T30030-2CR
T30030-3CR
T30030-4CR
T30060-2CR
T30060-3CR
T30060-4CR
T30100-1CR
T30100-2CR
T30100-3CR
T30200-1C
T30200-3C
T30400-1C
T30600-1C
Dimensions - in
1.63"
0.72"
0.16"
Catalog numbers
Amps
1/2-30
1
2-30
31-60
31-60
61-100
61-100
101-200
101-200
201-400
401-600
T30030-S
SECTION X-X
Fig.
no.
1
1
2
Wire range
SR #10-18 Cu
CR #6-14 Cu/Al
CR #2-14 Cu/Al
SR #10-18 Cu only
1/0-8 Cu/Al
3
4
5
6
250kcmil-6 Cu/Al
600kcmil-2/0 Cu/Al
(2) 600kcmil-4/0 Cu/Al
Figure 1. 12-60A
0.69"
0.91"
Poles
2
3
4
2
3
4
1
2
3
1
3
1
1
1.20"
A
B
1.63"
0.72"
0.16"
0.91"
2.75" 2.5"
Catalog
number
T30030-2
T30060-2
T30030-3
T30060-3
T30030-4
T30060-4
T30060-C
SECTION Z-Z
Z
0.44" Full
0.20" Radius
C
1007July 2015
Eaton.com/bussmannseries
Dimensions - in
A
B
C
2.41
1.03
2.41
1.03
3.44
1.03
2.06
3.44
1.03
2.06
4.47
2.06
3.09
4.47
2.06
3.09
Figure 2. 61 to 100A
2.06"
0.84"
1.41" (2 POLE)
2.81" (3 POLE)
X
2.56"
3.06"
1.94"
0.81"
X
0.38"
0.75"
2.25"
0.28" DIAMETER
0.63" C'BORE 0.5" DEEP
1.69"
0.52" C'BORE
0.55" DEEP
2.39"
0.05"
1.25"
0.22" DIA.
2.25"
REF.
4.78"
1.125"
6"
3"
Figure 4. 200A
4.87"
3"
1.695"
.996"
1.25"
6"
1.125"
0.63"
2.25"
0.28" DIAMETER
0.63" C'BORE 0.5" DEEP
2.75"
1.84"
0.282" DIAMETER THRU HOLE
0.625" C'BORE 0.438" DEEP
3.06"
2.38"
2.375"
0.81"
0.625"
4.46"
2.03"
5.75"
2" 3"
3.44"
3"
0.75"
Fuse holders
and blocks
0.33" DIAMETER
0.75" C'BORE 0.5" DEEP
1007July 2015
Eaton.com/bussmannseries
9-37
T600
Specifications
Description: T600 (600V) fuse blocks for use with Class T
fuses (Bussmann series JJS).
Dimensions: See dimensions illustrations.
Poles: 1 to 3
Ratings:
Volts: 600Vac/dc
Amps: 12 - 600A
SCCR: 200kA RMS Sym.
Agency information: CE, UL Listed UL 4248, Guide IZLT,
File E14853, CSA Certified, Class 6225-01, File 47235.
Flammability rating: UL 94V0.
T60600-1C
T30030-2CR
Catalog numbers
Screw
T60030-1SR
T60030-2SR
T60030-3SR
T60060-1SR
T60060-2SR
T60060-3SR
Box lug
T60030-1CR
T60030-2CR
T60030-3CR
T60060-1CR
T60060-2CR
T60060-3CR
T60100-1C
T60100-2C
T60100-3C
T60200-1C
1B0089*
T60400-1C
T60600-1C
Amps
1
2-30
1/2-30
31-60
31-60
61-100
61-100
101-200
101-200
201-400
401-600
Fig.
Poles no.
1 1
1
2
3
1 2
2
2
3
1 3
3
2
3
1
4
3
5
1
6
1
7
Wire range
SR #10-18 Cu
CR #2-14 Cu/Al
CR #2-14 Cu/Al
SR #10-18 Cu only
2/0-14 Cu/Al
250kcmil-6 Cu/Al
600kcmil-2/0 Cu/Al
(2) 600kcmil-4/0 Cu/Al
* UL Listed, Guide IZLT, File E14853, CSA Certified Class 6225-01, File 21455M18
Dimensions - in
Figure 1. 12 to 30A
0.5"
1.44"
3.19"
0.55"
1.563"
1.44"
0.33" 0.55"
2.59"
1.16"
0.33"
0.55"
3.75"
2.31"
0.33"
0.22" DIAMETER
0.5" C'BORE
0.33"
1.42"
Figure 2. 31 to 60A
0.5"
1.75"
0.59"
1.81"
0.63" 0.59"
3.34"
1.53"
0.63"
0.59"
4.86"
3.06"
0.63"
0.22" DIAMETER
2.94"
0.5" C'BORE
1.63"
1.47"
9-38
1007July 2015
Eaton.com/bussmannseries
Figure 3. 61 to 100A
1.69" (1 POLE)
3.09" (2 POLE)
4.5" (3 POLE)
1.125"
1.41" (2 POLE)
2.81" (3 POLE)
0.84"
6"
3"
1.25"
0.78"
2.5"
0.22" DIA.
0.52" C'BORE
0.55" DEEP
2.34"
REF.
2.56"
2.39"
X
0.38"
0.05"
2.25"
0.28" DIAMETER
0.63" C'BORE 0.5" DEEP
3.06"
1.94"
0.81"
SECTION Z-Z
0.75"
9/32
C-Bore 0.5
3"
1.25"
4.5
3.0
6"
1.125"
0.63"
2.72"
2.25"
0.28" DIAMETER
0.63" C'BORE 0.5" DEEP
7.0
2.25
3/16
7.75
3.06"
2.38"
0.81"
2.95"
6.75"
2" 3"
3.44"
3"
0.75"
Fuse holders
and blocks
0.33" DIAMETER
0.75" C'BORE 0.5" DEEP
1007July 2015
Eaton.com/bussmannseries
9-39
BG and G
Specifications
Description: Class G fuse blocks for use
with Class G fuses (Bussmann series SC).
Dimensions: See Data Sheet 1106
Poles: 1 to 3
Ratings:
Volts: 600Vac/dc (0-20A)
480Vac/dc (25-60A)
Amps: 1-60A (See catalog numbers
table)
SCCR: 100kA RMS Sym.
Agency information: CE, UL Listed
Guide IZLT, File E14853, CSA (Class
6225-01, File 47235).
DIN-Rail adapters: See page 16-5 for
DRA-1 and DRA-2.
Catalog numbers
Screw
with
quick
connect*
BG3011SQ
BG3012SQ
BG3013SQ
BG3021SQ
BG3022SQ
BG3023SQ
BG3031S
BG3032S
BG3033S
Pressure
plate w/
quick
connect*
BG3011PQ
BG3012PQ
BG3013PQ
BG3021PQ
BG3022PQ
BG3023PQ
BG3031P
BG3032P
BG3033P
Terminal type
Box
lug
BG3011B
BG3012B
BG3013B
BG3021B
BG3022B
BG3023B
BG3031B
BG3032B
BG3033B
G30060-3C
Box lug
w/retaining
clip
G30060-1CR
G30060-2CR
G30060-3CR
Amps Poles
1
1
1-15
to
2
15
3
20
1
20
2
3
25
1
25-30
to
2
30
3
35
1
35-60
to
2
60
3
PF1-WH (White)
PF1-BK (Black)
1007July 2015
Eaton.com/bussmannseries
BH
Specifications
Description: For use with Bussmann series high speed
fuses.
Ratings:
SCCR: 200kA RMS Sym. or fuse IR, whichever
is lower.
Agency information: CE, UL Recognized, Guide EZLT2,
File No. E14853 up to 700V, CSA Certified, Class 6225-01,
File No. 47235 up to 700V.
BH-0122
BH-1001
BH-1002
BH-1003
BH-1131
BH-1132
BH-1133
Catalog numbers
BH-2001
BH-2002
BH-2003
BH-2031
BH-2032
BH-2033
BH-3003
BH-3004
BH-3033
BH-3144
BH-3145
Specifications
Description: 3-pole only, modular type fuse blocks for
Class H and J fuses with standard reinforced retaining clips.
Ratings:
Volts: 250V (0-60A see catalog numbers table)
600V (35-60A see catalog numbers table)
Amps: 0-60A @ 250Vac/dc (see catalog numbers table)
35-60A@600V (see catalog numbers table)
SCCR: Class J 200kA, Class H 10kA
Agency information: CE, UL Recognized, Guide IZLT2,
File E14853, CSA Certified, Class 6225-01, File 47235.
Typical applications
Up to 60A, space confined, control circuits
Catalog numbers
Fuse
Screw
Pressure plate class
Volts
11241-3SR* 11241-3PR*
H
250
250
11242-3SR
11242-3PR
11241-3SR
11241-3PR
600
H
11242-3SR** 11242-3PR**
11239-3SR
11239-3PR
600
11240-3SR** 11240-3PR**
11241-3SR
11241-3PR
J J
600
11239-3SR* 11239-3PR*
Amps
60
60
35
30
60
60
30
60
Fig.
no.
1
2
1
2
1
2
1
1
Figure 1
Fuse holders
and blocks
Refer to the data sheet numbers below for the catalog code
description information.
Figure 2
1007July 2015
Eaton.com/bussmannseries
9-41
SOU
Features/Benefits
Bussmann series box cover units provide a low-cost method
of controlling and protecting small motors when used with
Bussmann series Type T, Fusetron, dual-element fuses.
Provide low-cost supplementary protection and
disconnection of 125V or less, single phase circuits.
SRU
SSU
Typical applications
Fractional horsepower, 125 volt single-phase motor circuits
General 125 volt supplemental circuits
STY
SSN
Catalog numbers
Catalog
numbers
SOU
SRU
SSU
SOW
SRW
SSW
SOX
SRX
SSX
SOY
SRY
SSY
SSY-RL
STY3
SCY
SOY-B
SSN
1
2
3
4
Type box
Handy
22 " "Handy
1 14
4
Switch
22343"4"Switch
4"Octagon
Octagon
4"
Square
4"4"Square
Single gang
Fuse holder3
Single Double
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Receptacle
outlet to load
125V 250V
X
X
X
X
X
Switch
control1
Switch
light2
X
X
X
X
X
X
X(2)
X
Motor
size
(max)
3
4hp
1
2hp
1
2hp
3
4hp
1
2hp
1
2HP
3
4hp
1
2hp
1
2hp
3
4hp
1
2hp
1
2hp
1
2hp
1
2hp
2hp (2)
4hp
2hp
3
1
General data
125V, 15A
125V, 15A
125Vac, (do not use on dc), 15A
125V, 15A
125V, 15A
125Vac, (do not use on dc), 15A
125V, 15A
125V, 15A
125Vac, (do not use on dc), 15A
125V, 15A
125V, 15A
125Vac, (do not use on dc), 15A
125Vac, (do not use on dc), 15A
125Vac, (do not use on dc), 15A
125Vac, (do not use on dc),
can protect two motors, 15A
125V, protects two motors, 15A
Weatherproof model, 15A
1007July 2015
Eaton.com/bussmannseries
Agency4
listing/
certification
UL, CSA
UL
UL, CSA
UL, CSA
UL
UL, CSA
UL, CSA
UL
UL, CSA
UL, CSA
UL
UL, CSA
UL
UL
UL
UL
HHB
HRK
Specifications
Description: Water-resistant in-line
fuse holder for 14" x 114" fuses.
Dimensions: See Dimensions
illustration.
Construction: Thermoplastic rubber
body with tin-plated, copper contacts.
Ratings:
Volts: 32V
Amps: 30A max
Specifications
Description: Universal in-line fuse
holder for 14" x 78", 1" and 114" fuses.
Dimensions: See dimensions
illustration.
Construction: Nylon body with
tin-plated, copper contacts.
Ratings:
Volts: 32V
Amps: 30A max
Flammability rating: UL 94V2.
Pull force: 5lbs minimum to separate
fuse holder housing with fuse installed.
Specifications
Description: Universal in-line fuse
holder for 14" x 78" to 1 14" fuses.
Dimensions: See dimensions
illustration.
Construction: 8" (203mm) #14 lead
wires.
Ratings:
Volts: 32V
Amps: 15A max
Catalog
numbers
BP/HFB-RP*
BK/HFB
BK/1A2294
1A2294-01
Catalog numbers
Description
Standard pack (10-in)
Bulk pack (100-in)
HFB replacement contact clip
HFB-10** replacement contact clip
Features/benefits
Simple assembly with one-piece
thermoplastic (important information
molded into body)
High visibility yellow color for easy
identification in dark or hard-to-access
locations
Ideal for shock and vibration
environments; withstands many
organic solvents; temperature range 40/+150C
Typical applications
Supplemental, low voltage, low
amperage control circuits
Typical applications
Supplemental, low voltage, low
amperage control circuits
Typical applications
Supplemental, low voltage, low
amperage control circuits
Catalog
number
Catalog numbers
*Accepts #12 to #16 wire leads (not provided with basic fuse
holder). See Data Sheet for recommended crimp tools.
HRK-R*
15
Fuse description
1
4" diameter fuses of
different lengths.
32
Dimensions - in (mm)
2.19"
(55.6mm)
0.75"
(19.1mm)
0.69"
(17.5mm)
**RoHS compliant.
Fuse length
7
8" (AGW)
1" (AGX)
114" (AGC, MDL)
Amp
rating Volts
Catalog number
1.56"
(39.7mm)
0.38"
(9.5mm)
Dimensions - in (mm)
Dimensions - in (mm)
3"
(76.2mm)
0.75"
(19.1mm)
0.53"
(13.5mm)
Fuse holders
and blocks
Eaton.com/bussmannseries
9-43
HR and HM
HFA
Specifications
Description: In-line
fuse holders for SFE
and 14" dia. x various
length fuses.
Dimensions: See
dimensions
illustration.
Ratings:
Volts: 32V
Amps: 20A
Specifications
Description: In-line water-resistent
fuse holders for 14" x 114" fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 250V
Amps: 20A
Typical applications
Supplemental, low voltage, low
amperage control circuits
Catalog
numbers
HRJ*
HRI
HRH
HRE
HRG
HRF
HMJ**
HMI
HMH
HME
HMG
HMF
Catalog
numbers
HFA
HFA-HH*
Includes
fuse
SFE-20
SFE-14
SFE-9
SFE-712
SFE-6
SFE-4
SFE-20
SFE-14
SFE-9
SFE-712
SFE-6
SFE-4
Catalog numbers
Wire length
and size
Catalog numbers
Terminals
Crimp #12 - #16
1
4" quick connect
*No UL recognition.
19 of #14
8 of #14
HHT
HHJ-A
HHJ-B
HHI-B
Catalog
number
9838
9841
Replacement contacts
Symbol
HHJ-A
HHJ-B
Dimensions - in (mm)
2.19"
(55.6mm)
0.75"
(19.1mm)
0.69"
(17.5mm)
1.56"
(39.7mm)
0.38"
(9.5mm)
Specifications
Description: In-line fuse holders for
5 x 15mm or 5 x 20mm fuses.
Dimensions: See dimensions
illustration.
Construction: Black thermoplastic
body with brass contacts, wire: 16
AWG, red.
Ratings:
Volts: 32V
Amps: 5A (5 x 15mm)
10A (5 x 20mm)
Catalog number
HHT
Fuse size
5 x 15mm and 5 x 20mm
Catalog numbers
1007July 2015
Eaton.com/bussmannseries
HEG
HEC
HEJ
HEX
Specifications
Description: Single-pole,
non-breakaway, in-line fuse
holders for Type SC fuses,
480V (or less).
Ratings:
Volts: 600V
Amps: 0-15A
Fuse size: 1332" x 1.31"
Specifications
Description: Single-pole,
non-breakaway, in-line fuse
holders for type SC-25, &
SC-30 fuses, size
13
32" x 1 58".
Ratings:
Volts: 480V
Amps: 25-30A
Specifications
Description: Single-pole,
non-breakaway, in-line fuse
holders for type SC and type
HVW fuses, size 1332" x 2 14".
Ratings:
Volts: 480V
Amps: 35-60A Type SC
12-6A type HVW
Specifications
Description: Double-pole inline fuse holders for 1332" x 1 12"
fuses (typically fuse types
BAF, FNM, FNQ, and KTK
1
10 - 30A).
Ratings:
Volts: 600V
Amps: 0-30A
HEG-AA
HEC-AA, HEC-RW-RLB-R
Optional boots:
Catalog number
Optional boots:
Catalog numbers
Catalog numbers
Optional boots:
HEH
HEZ
HEY
Description: Single-pole,
non-breakaway, in-line
fuse holders for 20A Type
SC fuses and 110-20A BBS.
Ratings:
Volts: 600V
Amps: 0-20A
Agency information:
CSA - 15A.
Specifications
Description: Waterproof
(IPX7), single-pole Class
CC in-line fuse holders.
Holds Bussmann series
fuse types: LP-CC, FNQ-R
and KTK-R.
Ratings:
Volts: 600V (or less)
Amps: Up to 30A*
Specifications
Description: Double-pole
in-line fuse holders for KTKR fuses with optional breakaway receptacle, polarized,
and accepting Class CC
branch circuit fuses
(Bussmann series KTK-R,
FNQ-R and LP-CC; 600V or
less, 200kA IR).
Ratings:
Volts: 600V
Amps: 0-30A
Specifications
HEH-AA, HEH-AD
Catalog numbers
2A0660 Single conductor
2A0661 Two conductor
Optional boots:
Conductors: Lineside
and Loadside**
#12 to #8 Crimp terminal
#12 to #3 Setscrew terminal
HET
HEY-AA, HEY-AB, HEY-AC, HEYAD, HEY-AE, HEY-AL, HEY-AWDRLC-A, HEY-AW-DRLC-B, HEYAW-DRYC, HEY-BB, HEY-JJ
Specifications
Description: Single-pole
in-line holder with a
permanent solid neutral
identified by white plastic
coupling nut.
HET-AA, HET-AB, HET-AW, HETAW-RLC-A, HET-AW-RLC-B, HETAW-RLC-C, HET-AW-RLC-J, HETAW-RYC, HET-BB, HET-BW-RLC-B,
HET-BW-RYC, HET-JJ, HET-JK,
HET-JW, HET-JW-RLC-J, HET-JWRYC, HET-KK
Catalog numbers
Catalog numbers
1007July 2015
Fuse holders
and blocks
Catalog numbers
Eaton.com/bussmannseries
9-45
HEB holders
Description:
Amps:
Part number
Single conductor
2A0660
Dual conductor
2A0661
To order:
Specify catalog symbol HEB and the loadside terminal code plus the
letter W. Then select a lineside terminal code that is available with
the loadside terminal. Example: HEB-BW-RCL-B defines a breakaway
holder with a loadside copper crimp terminal for a single #6 or two
#10 wires with a lineside copper crimp terminal for a single #6 or
two #10 wires.
Ratings:
Volts:
Description
HEB
J
K
Lineside
terminal
Loadside
terminal
Catalog
symbol
HEB - A W - RYC
Agency
Information
UL
CSA
Loadside terminal
Terminal
type
Lineside terminal
Wire range*
Terminal
type
Wire range*
RLC-A
Cu crimp
Cu crimp
RLC-B
Cu crimp
Cu crimp
HEB-AB
RLC-C
Cu crimp
Cu crimp
#4 str; (2) #8
HEB-AC
RLC-J
Cu crimp
Cu setscrew
#3-8
HEB-AJ
RYC
Cu crimp
Cu setscrew
(2) #2-12
HEB-AK
RLA
Cu crimp
Al setscrew
#2-12
HEB-AL
RYA
Cu crimp
Al setscrew
(2) #2-12
HEB-AY
RLC-A
Cu crimp
Cu crimp
HEB-BA
RLC-B
Cu crimp
Cu crimp
HEB-BB
RYC
Cu crimp
Cu setscrew
(2) #2-12
RLC-J
Cu setscrew
#3-8
Cu setscrew
#3-8
HEB-JJ
HEB-AA
HEB-JK
RYC
Cu setscrew
#3-8
Cu setscrew
(2) #2-12
RLC-J
Cu setscrew
#2-12
Cu setscrew
#3-8
RYC
Cu setscrew
#2-12
Cu setscrew
#2-12
HEB-LL
RLA
Al setscrew
#2-12
Al setscrew
#2-12
RLC-J
Al setscrew
#2-12
Cu setscrew
#3-8
RYA
Al setscrew
#2-12
Al setscrew
#2-12
Non-breakaway
equivalent
1007July 2015
Eaton.com/bussmannseries
HEB holders
To order:
Specify catalog symbol HEB and the loadside terminal code. Then select
a lineside terminal code that is available with the loadside terminal.
Example: HEB-BB defines a non-breakaway holder with a loadside
copper crimp terminal for a single #6 or two #10 wires with a lineside
copper crimp terminal for a single #6 or two #10 wires.
Lineside
terminal
Loadside
terminal
Catalog
symbol
HEB - A A
Loadside terminal
UL
CSA
Terminal
type
Cu crimp
Lineside terminal
Wire range*
Terminal type
Wire range*
Breakaway equivalent
Cu crimp
HEB-AW-RLC-A
Cu crimp
Cu crimp
HEB-AW-RLC-B
Cu crimp
Cu crimp
#4 str; (2) #8
HEB-AW-RLC-C
Cu crimp
Cu crimp
#2 str; (2) #6
Cu crimp
Cu setscrew
#3-8
HEB-AW-RLC-J
Cu crimp
Cu setscrew
#2-12
HEB-AW-RYC
Cu crimp
Al crimp
#1-2
Cu crimp
Al setscrew
#2-12
HEB-AW-RLA
Cu crimp
Cu solid
Cu crimp
Al setscrew
#2-12
HEB-AW-RYA
Cu crimp
Cu crimp
Cu crimp
HEB-BW-RLC-B
Cu crimp
HEB-BW-RLC-A
Cu crimp
Cu crimp
#4 str; (2) #8
Cu crimp
Cu crimp
#2 str; (2) #6
Cu crimp
Cu solid
Cu crimp
#4 str; (2) #8
Cu crimp
#4 str; (2) #8
Cu crimp
#2 str; (2) #6
Cu crimp
#2 str; (2) #6
Cu crimp
#18-20
Cu crimp
Cu setscrew
#3-8
Cu setscrew
#3-8
HEB-JW-RLC-J
Cu setscrew
#3-8
Cu setscrew
#2-12
HEB-JW-RYC
Cu setscrew
#3-8
Al setscrew
#2-12
Cu setscrew
#3-8
Cu solid
Cu setscrew
#3-8
Al setscrew
#2-12
Al setscrew
#2-12
Al setscrew
#2-12
HEB-LW-RLA
Al crimp
6 sol; 8 str
Al crimp
#6 sol; #8 str
Al crimp
4 sol; 6 str
Al crimp
#4 sol; #6 str
Al crimp
Al crimp
Al crimp
#1-2 str
Al crimp
#1-2 str
Al crimp
1/0 str
Al crimp
1/0 str
Cu solid
Cu solid
HEB
Agency
Information
L
N
1007July 2015
Eaton.com/bussmannseries
9-47
HTC-35M
37.5mm
12.70mm +0.0
0.1
15mm
5.5mm
4mm
11mm
37.5mm
12.70mm +0.0
0.1
22mm
Ratings:
Volts: 250Vac
Amps: 10A UL, 10A VDE
Fuse access: Screwdriver slot
6.5mm
12.70mm +0.0
0.1
15mm
0.5mm
5.5mm
4mm
11mm
35.5mm
Ratings:
Volts: 250Vac
Amps: 10A UL, 10A VDE
Fuse carrier: Bayonet type
Specifications
Terminals:
Molded materials:
Solderability:
Agency information:
Electrical:
Shock safety:
Packaging:
9-48
15mm
16mm
HTC-70M
0.5mm
5.5mm
12.00mm +0.0
0.1
3.0x0.51mm
16mm
HTC-55M
Ratings:
Volts: 250Vac
Amps: 10A UL, 10A VDE
Fuse carrier: Bayonet type
12.00mm +0.0
0.1
3.0x0.51mm
15mm
HTC-40M
12.00mm +0.0
0.1
4.8x0.51mm
4mm
11mm
12.70mm +0.0
0.1
Ratings:
Volts: 250Vac
Amps: 10A UL, 10A VDE
Fuse access: Threaded cap
12.00mm +0.0
0.1
3.0x0.51mm
16mm
Tin-plated brass.
High temperature thermoplastic that meets the flammability ratings of UL 94V0; glow wire test:
960C per IEC 60695-2-1.
In accordance with IEC 68-2-20.
cURus, VDE
Contact resistance: 10 megohm; iInsulation resistance: 10M; dielectric strength
2000Vac.
PC2 (fuse holders).
Standard qty 10 (No Prefix), bulk qty 100 (prefix catalog number with BK/).
1007July 2015
Eaton.com/bussmannseries
HKP-OO
Specifications
Description: Standard fuse holders.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 250V
Amps: 30A
Specifications
Description: Fuse holders with 14"
quick-connects.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 250V
Amps: 15A
Catalog numbers
Specifications
Description: Snap-lock fuse holders.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 250V
Amps: 30A
Catalog numbers
Catalog numbers
Catalog
numbers
HKP
HKP-L
HKP-W
Fuse
description
Dimensions - in (mm)
Catalog
numbers
HKP-BBHH
HKP-HH
HKP-LW-HH
Fuse
description
HKP w/ 14" quick-connects, nut and washer
assembled.
HKP w/ 14" quick-connect.
HKP w/ drip-proof knob, 2250V stand-off
barrier and 14" quick-connects.
Catalog
number
HKP-OO
Fuse
description
HKP with snap-lock
Dimensions - in (mm)
.75"
(19.1mm)
Dimensions - in (mm)
FU
E
US
SE
.855"
(21.7mm)
1.56"
(39.7mm)
1.17"
.800"
F USE
(20.3mm)
(22.6mm)
.811"
(20.6mm)
Specifications
Terminals:
Agency information:
Replacement Parts:
1007July 2015
Eaton.com/bussmannseries
Fuse holders
and blocks
Bayonet-type knob.
Vibration resistant.
For panels up to 516" (7.9mm) thick.
CE (HKP, HKP-L, HKP-W, HKP-OO), UL Recognized Guide IZLT2, File E14853, CSA
Certified Class 6225-01, File 47235
Cap: 9435-1/2
Plastic nut: BK/1A4287 (100 pieces minimum)
Metal nut: BK/1A4806-2 (100 pieces minimum)
Washer: 9732
9-49
Panel mounted fuse holders for 5 x 20mm and 1/4 x 1 1/4 fuses
HTB
Specifications
Description: Fuse holders with knob-type carriers.
Dimensions: See dimensions illustrations.
Construction: High temperature, flame retardant
thermoplastic; UL Component Recognized; UL 94V0;
mounting nut, spacer-black polycarbonate. Terminals:
tin-plated brass.
Electrical data: Insulation resistance (per IEC #257)
10,000 ohms @ 500Vdc; contact resistance (per IEC #257)
0.005 ohms Max @ 1A; standoff voltage (per IEC #257)
480V/Mil @ 0.125 thickness.
Agency information: CE, UL Recognized Guide IZLT2,
File E14853, 14 dia fuse @ 20A, 5mm dia fuse @16A @
250V, CSA 16A @ 250V Class 6225-01 File 47235; VDE
Certified: 136128, HTB-XXM, SEMKO Certification: Ref.
#0146149/01, HTB-XXM.
Mounting: Withstands 15 to 20 Lb-In torque to mounting
nut when mounting fuse holder to panel.
Environmental: Operating temperature range -55C to
85C.
Dimensional data - in (mm)
Knob type carrier
Common dimensions:
Length (knob type) - 1.69"
(42.9mm) plus in-line terminal
NOTE: Plus in-line terminal
0.47"
1.125"
(11.9mm)
(28.6mm)
0.09" NOM.
Replacement parts
Terminal options
Maximum
panel
thickness
Solder/
3
16" quick-connect
In-line
Rt. angle
0.34"
0.33"
(8.7mm)
(8.3mm)
4" quick-connect
In-line
Rt. angle
0.47"
0.45"
(11.9mm)
(11.5mm)
HTB-26I-R
HTB-28I-R
Carrier options
1
4" x 114"
5 x 20mm
(I equals inches) (M equals metric)
Knob
Knob
0.30
HTB-22I-R
HTB-24I-R
7.62mm
HTB-22M-R
0.125
3.18mm
HTB-42I-R
HTB-42M-R
HTB-44I-R
HTB-46I-R
HTB-48I-R
0.30
7.62mm
HTB-62I-R
HTB-62M-R
HTB-64I-R
HTB-66I-R
HTB-68I-R
0.125
HTB-82I-R
HTB-84I-R
HTB-86I-R
HTB-88I-R
(2.4mm)
0.69"
0.91"
(17.5mm)
(23.0mm)
0.67"
0.92"
(17.1mm)
(23.4mm)
0.47"
1.125"
(11.9mm)
(28.6mm)
3.18mm
HTB-82M-R
1007July 2015
Eaton.com/bussmannseries
Panel mounted fuse holders for 5 x 20mm and 1/4 x 1 1/4 fuses
HTB
Common dimensions:
(Screwdriver slotted)
1.75" (44.5mm)
NOTE: plus in-line terminal
0.17"
1.58"
(4.37mm)
(40.03mm)
HTB-3
0.41"
1.34"
(10.31mm)
(34.13mm)
HTB-5
0.17"
1.59"
(4.37mm)
(40.08mm)
HTB-9
Terminal options
Maximum
panel
thickness
Solder/
3
16" quick-connect
In-line
Rt. angle
0.34"
0.33"
(8.7mm)
(8.3mm)
Carrier options
4" quick-connect
Rt. angle
In-line
0.47"
0.45"
(11.9mm)
(11.5mm)
0.30
HTB-32I-R
HTB-34I-R
HTB-36I-R
7.62mm
HTB-32M-R
0.125
HTB-52I-R
HTB-54I-R
3.18mm
HTB-52M-R
0.125
HTB-92I-R
HTB-94I-R
3.18mm
HTB-92M-R
HTB-56I-R
HTB-96I-R
HTB-38I-R
HTB-58I-R
HTB-98I-R
1
4" x 1 14"
5 x 20mm
(I equals inches) (M equals metric)
Screwdriver
Screwdriver
X
X
X
X
X
X
HTBS
Packing
blank (Std.) 10 fuse holders
in a carton
BK 100 fuse holders in a
cardboard shelf package
Product
symbol
Fuse carrier
I 1/4 x 1 1/4
M 5 x 20mm
Splash Proof
Cap with o-ring
(optional on knob
holders only)
Packaging
(blank) Std.
BK/ Bulk
-R
Product
symbol
FT knob t ype
(For 20, 40, 60,
and 80 only)
Fuse carrier
I 1/4 x 1 1/4
M 5 x 20mm
ST Screwdriver
Slotted (For 30,
50, and 90 only)
RoHS
compliant
Fuse holders
and blocks
*Profile varies with panel thickness. Holder installs through rear of panel.
1007July 2015
Eaton.com/bussmannseries
9-51
HLD
HJL
HK
Specifications
Description: Pin indicating for
1
4" x 114" fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 250V
Amps: 15A
Agency information: CE, UL
Recognized, File E14853, Guide IZLT2.
Specifications
Description: Neon lamp indicating for
1
4" x 1" fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 250V
Amps: 15A
Agency information: None
Specifications
Description: Neon and incandescent
lamp indicating for 14" x 114" fuses
Dimensions: See dimensions
illustration.
Ratings:
Volts: 250V
Amps: 15A (HKL, HKL-X)
20A (HKR, HKT, HKU, HKX)
Agency information: CE, UL
Recognized, (Guide IZLT2, File
E14853), CSA Certified
(Class 6225-01, File 47235).
Catalog
numbers*
HLD
HLD-HH
Catalog numbers
Terminals
Solder terminals
1
4" quick-connect terminals
Catalog
number*
HJL
Lamp
Volts
color
90 to 250 Clear
Dimensions - in (mm)
2.81"
(71.4mm)
Dimensions - in (mm)
1.19"
(30.2mm)
0.86"
(21.8mm)
Washer
0.69"
(17.5mm)
Octagonal Sides
(69.9mm Max.)
0.505" 0.005
(16.0mm 0.13mm)
0.473" 0.005
Knob
type
Oct
Catalog number
0.81"
Octagonal Sides
(20.6mm)
Catalog
numbers
HKL*
HKL-X*
HKR**
HKT**
HKU**
HKX**
Lamp
volts
90-250
90-250
22-30
13-22
4-6
22-33
Catalog numbers
.630" + .005"
(16.0mm + .13mm)
.590" + .003"
(14.6mm + .08mm)
2.81"
(71.4mm)
Flat-Sides
(12.0mm 0.13mm)
1.19"
(30.2mm)
0.81"
Octagonal Sides
(20.6mm)
(16.0mm + .13mm)
.573" + .003"
(14.6mm + .08mm)
Knob color/type
Clear/Oct
Clear/FS
Amber/Oct
Amber/Oct
Red/Oct
Amber/FS
1007July 2015
HPF
HPS
HPG
HPD
#10 wire max
for solder connection
Specifications
Description: Standard fuse holders
with screw-type knob for 1332" x 1516" to
112" fuses.
Dimensions: See dimensions
illustration.
Agency information: CE, UL
Recognized, Guide IZLT2, File E14853;
CSA Certified, Class 6225-01, File
47235.
Flammability rating: UL 94HB.
Terminals: Combination 14"
quick-connect/solder terminals.
Catalog numbers
Catalog
numbers
HPF
HPF-C
HPF-L
HPF-EE
HPF-JJ
HPF-FF1
HPF-RR
HPF-WT
1
2
3
Amp
ratings
302
303
5
15
20
302
302
302
Volts AC
600
6003
600
600
600
480
600
600
Fuse description
1 12" (38.1mm)
1 12" (38.1mm) clear knob.
BBS, 1332" x 1 38" fuses.
SC 0-15, 1332" x 1 516" fuses.
SC 20, 1332" x 1 1332" fuses.
SC 25 & 30, 1332" x 1 58" fuses.
KTK-R, LP-CC & FNQ-R
Class CC fuses.
Splash-proof knob. 1332" x 1 12"
(38.1mm)
No CSA Certification
20A max when used with quick-connect terminals.
HPF-C ratings for CSA-15A, 250V
Dimensions - in (mm)
Specifications
Description: Standard fuse holders
with bayonet-type knob for 1332" x 1516"
to 112" fuses.
Dimensions: See dimensions
illustration.
Agency information: CE, UL
Recognized, Guide IZLT2, File E14853;
CSA Certified, Class 6225-01, File
47235.
Flammability rating: UL 94HB.
Terminals: Combination 14" quickconnect/solder terminals.
Catalog numbers
Catalog
symbol
HPS
HPS-L
HPS-EE*
HPS-JJ*
HPS-F-EE1
Amp
ratings
30 2 3
5
15
20
15
Volts AC
600
600
600
600
600
Fuse description
13
32" x 1 12"
BBS, 1332" x 1 38" fuses.
SC 0-15, 1332" x 1 516" fuses.
SC 20, 1332" x 1 1332" fuses.
Sleeve on body, leaded for
13
32" x 1516" fuses.
1
2
HPS-FF* 30
480
SC 25 & 30, 1332" x 1 58" fuses.
1
2
HPS-RR* 30
600
KTK-R, LP-CC, FNQ-R Class
CC fuses.
*-EE, -JJ, -FF and -RR versions are UL Recognized for
applications requiring branch circuit protection.
1
No CSA Certification
2
20A max when used with quick-connect terminals.
3
HPS rated at 250V for CSA
Specifications
Description: Standard fuse holders
with bayonet-type knob for 1332" x 112"
fuses.
Dimensions: See dimensions
illustrations.
Agency information: CE, UL
Recognized, (Guide IZLT2, File
E14853).
Flammability rating: UL 94V0 - fuse
holder body UL 94HB - Knob.
Catalog numbers
Catalog Amp
numbers ratings Volts AC Fuse description
13
HPG*
301
600
32" x 1 12" fuses
HPG-EE* 15
600
SC 0-15, 1332" x 1 516" fuses.
1
13
HPD**
30
600
32" x 1 12" fuses
1
20A max when used with quick-connect terminals.
*HPG and HPG-EE has combination 14" quick-connect/solder
terminals on both side (load) and rear (line) terminals.
**HPD has combination 14" quick-connect/solder terminal on
side (load) terminal only. Rear (line) terminal is 316" shorter
than HPG. Rear terminal solder only.
Dimensions - in (mm)
HPG, HPG-EE
2.81"
(71.4mm)
0.88"
(22.2mm)
1.125"
(28.6mm)
Dimensions - in (mm)
With Fuse
2.81" Max.
(71.4mm)
With Fuse
FU
USE
SE F
FUS
1.125"
1.00"
1.31"
2.81"
1.78"
(71.4mm)
HPD
0.88"
(22.2mm)
0.180" DIA.
(4.6mm)
(28.6mm)
0.88"
1.78"
(22.2mm)
0.250" 0.003"
(6.35 .08mm)
(Typ.2)
(45.2mm)
2.69" Max.
(68.3mm)
Without Fuse
0.250" .003"
(6.35 .08mm)
(Typ.2)
0.180"
1.125"
(4.6mm)
(28.6mm)
0.80"
(20.2mm)
2.41"
(64.3mm)
Without Fuse
Fuse holders
and blocks
Eaton.com/bussmannseries
9-53
HPM
HPC-D
HPS2
Specifications
Description: Standard fuse holder
with screw-type knob for 1332" x 112"
fuses.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 600Vac/dc
Amps: 30A1
Catalog
numbers
HPM
HPM-D
Catalog numbers
Description
1
4" quick-connect/solder
Splash-resistant knob 2
Specifications
Description: Fuse holder with
screw-type knob for 1332" x 112" fuses.
Supplied with O-ring and panel gasket.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 600Vac/dc
Amps: 30A1
Catalog
number
HPC-D
Specifications
Description: For fuse size 1332" x 112",
meeting UL 1598 requirement that both
poles be removed simultaneously.
Dimensions: See dimensions
illustration.
Ratings:
Volts: 600V@30A
Amps: 0-30A 1
Catalog numbers
Description
Mount in panels up to 14" thick.
Catalog
numbers
HPS2
BK/HPS2
2.48"
(63.1mm)
Catalog numbers
Standard 10-in carton
Bulk 100-in carton
Dimensions - in (mm)
0.88"
Dimensions - in (mm)
(22.2mm)
With Fuse
2.73"
(69.5mm)
1.775"
0.94"
(45.1mm)
(23.8mm)
0.180"
1.41"
(30.6mm)
1.120"
(4.6mm)
(30.5mm)
2.594"
(65.89mm)
Without Fuse
Mounting Hole
Flange Rear of Panel
Mounting Hole
Flange Front of Panel
1.031" + 0.003"
0.250" 0.003"
(6.35 0.08mm)
(26.2mm + 0.08mm)
0.187" + 0.002"
(4.75mm + 0.05mm)
1.312" + 0.003"
(33.3mm + 0.08mm)
0.890" + 0.003"
(22.6mm + 0.08mm)
1.312" + 0.003"
(33.3mm + 0.08mm)
1007July 2015
Eaton.com/bussmannseries
8000
Specifications
Description: Bolt-in and snap-in mounting for 14" x 114"
fuses.
Construction: Blocks are molded flame retardant
thermoplastic. Clips are bright tin-plated, spring-bronze.
Ratings:
Volts: 300V
Amps: 25A (See catalog numbers table)
Agency information: CE, UL Recognized ; File E14853,
Guide IZLT2, CSA Certified Class 6225-01, File 47235.
Anti-rotation pin: Single-pole blocks may be ordered
without the anti-rotational pin simply by adding an X to the
number of poles (Example: BK/S-8000-1X).
Carton quantity: 10; shelf package: 100.
Bulk carton: Single-pole and 2-pole fuse blocks 1,000;
Multiple-pole fuse blocks 3- to 8-pole: 200; 9- to 12-pole:
50. When ordering bulk quantities, prefix BK/ to catalog
number: (Example: BK/S-8001-1-SNP).
Catalog numbers
Bolt-in mounting
Basic
catalog
numbers
S-8001S-8002S-8101S-8102S-8201S-8202S-8203S-8301-
Snap-in mounting
Catalog
numbers
S-8001-1-SNP
S-8002-1-SNP
S-8101-1-SNP
S-8102-1-SNP
S-8201-1-SNP
S-8203-1-SNP
Series
8000
8000
8100
8100
Terminal
Solder
16" Quick
connect
1
4" Quick
connect
side
Screw
3
8200
8200
8300
8300
Series
8000
8000
8100
8100
8200
8200
Terminal
Solder
16" Quick
connect
4" Quick
connect
3
1
Angle
0
40
0
40
0
40
Angle
0
40
0
40
0
Side
Agency
maximums
UL 30A
CSA 21A
UL 20A
CSA 13A
UL 30A
CSA 16A
UL 30A
CSA 25A
Agency
maximums
UL 25A
CSA 21A
UL 20A
CSA 13A
UL 20A
CSA 16A
Catalog Code
BK/
S-8 0
Specifications
Description: Single-pole fuse block for 14" x 114"
(6.4 x 31.8mm) size fuses.
Dimensions: See dimensions illustrations.
Construction: Bakelite base width 12" (12.7mm); springbronze, bright tin-lead plate clips.
Ratings:
Volts: 250V
Amps: 30A
4405 -
0 solder terminals
with integral terminal and clip
Dimensions - in (mm)
2.31"
(58.7mm)
0.69"
(17.5mm)
1.63"
(41.3mm)
Poles
(suffix)
1 - 12
4574 -
(41.3mm)
0.69"
(17.5mm)
Poles
(suffix)
Available
Available
only in
only in
single
single
pole
pole
00
0.27"
(6.7mm)
2499 -
Side quick-connect
Agency information: UL
Recognized, Guide IZLT2, File
E14853
Terminals: 14" (6.4mm); 15A, 250V
Dimensions - in (mm)
-00
1.63"
(41.3mm)
0.75"
(19.1mm)
0.27"
0.72" (6.7mm)
(18.3mm)
0.5"
(12.7mm)
Fuse holders
and blocks
4406 -
Dimensions - in (mm)
1 - 12
Prefix for
Bulk
Packing
Series 8000
Product Line
Type Terminal
0-Solder
1- Quick Connect
2 - Quick Connect
3 - Screw
Terminal Angle
01 - straight (0,)
02- 40
03 - side*
Number of Poles (1-12)
0.27"
(6.7mm)
1007July 2015
Eaton.com/bussmannseries
9-55
3828
Specifications
Description: Fuse block for 14" x 1" (6.4 x 25.4mm) fuses
with solder terminals.
Dimensions: See dimensions illustration.
Ratings:
Volts: 250V
Amps: 30A
Mounting: Mounting screw hole diameter is 0.147"
(3.7mm), diameter. Max mounting screw no. 6.
Specifications
Description: Single-pole fuse block for 14" x 1" fuses.
Dimensions: See dimensions illustrations.
Construction: Bakelite with 12" (12.7mm) width base.
Spring-bronze, bright tin-lead plated clips.
Ratings:
Volts: 250V
Amps: 30A
Mounting: Mounting screw hole diameter is 0.147"
(3.7mm), counterbore 0.636" (8.0mm) diameter. Max
mounting screw no. 6.
Catalog numbers
3828-1
3828-2
3828-3
3828-4
3828-5
3828-6
3828-7
3828-8
3828-10
3828-12
Catalog numbers
Poles
1
2
3
4
5
6
7
8
10
12
Catalog
Numbers
4520
4393
Catalog numbers
Description
Integral clip and straight solder terminals
Spare fuse block
Dimensions - in (mm)
1.88"
Dimensions - in (mm)
(47.6mm)
1.94"
(49.2mm)
0.63"
.188"
.598" (4.8mm)
(15.9mm)
(15.2mm)
0.19"
(4.8mm)
1.38"
1.38"
(34.9mm)
(34.9mm)
No. 4393 -
Dimensions - in (mm)
1.38"
(34.9mm)
0.188"
0.598" (4.8mm)
(15.2mm)
9-56
1007July 2015
Eaton.com/bussmannseries
3743
3835
Specifications
Specifications
Catalog
numbers
3835-1
3835-2
3835-3
3835-4
3835-5
3835-6
3835-7
3835-8
3835-9
3835-10
3835-12
Base* width
In (mm)
27
32 (21.4)
1 1316 (46.0)
2 2532 (70.6)
3 34 (95.2)
4 2332 (119.9)
5 1116 (144.5)
6 2132 (169.0)
7 58 (193.7)
8 1932 (218.8)
9 916 (242.9)
11 12 (292.1)
Catalog numbers
Poles
1
2
3
4
5
6
7
8
9
10
12
1.29"
0.19"
1.63"
(41.3mm)
2.75"
1.0"
0.323"
1.125"
4421Solder terminals
Base width 58" (15.9mm)
0.25"
(25.4mm) (6.4mm)
1.125"
0.25"
2.56"
0.897"
(22.78mm)(4.8mm)
(69.9mm)
3742
(65.1mm)
2.5"
(63.5mm)
Dimensions - in (mm)
0.500"
2.56"
Specifications
2.56"
(65.1mm)
0.897"
0.19"
(22.78mm) (4.8mm)
0.25"
(6.4mm)
(28.6mm)
0.78"
(19.8mm)
1.34"
(34.1mm)
0.144"
4515Screw terminals
Base width 34" (19mm)
Fuse holders
and blocks
1007July 2015
Eaton.com/bussmannseries
9-57
NDNF1-WH
NDNLFD1-WH
Specifications
Specifications
Catalog numbers
Catalog
number
NDNF1-WH
Color
White
numbers
LPF1-24
LPF1-120
LPF1-120-C
LPF1-220
LPF1-440
9-58
Catalog
Voltage
number
24
NDND1-WH
120
NDNFD1-WH
120
NDNLFD1-WH
220
440
NDNLFD1-WH 24
1007July 2015
Color
White
White
White
White
Eaton.com/bussmannseries
Indicator
NO
NO
90Vdc-600Vdc
115Vac-600Vac
24V
10
Contents
1007July 2015
Eaton.com/bussmannseries
10-1
Power distribution
and terminal blocks
Description
Page
Selection table for SCCR PDBs and power terminal blocks . . .10-2
Power distribution blocks
PDBFS enclosed, with high SCCR . . . . . . . . . . . . . . . . . . . . 10-3
PDB with high SCCR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-4
Power terminal blocks
163 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-5
11675 2- to 12-pole quick-connect . . . . . . . . . . . . . . . . . . . . 10-7
11725 2- to 4-pole quick-connect . . . . . . . . . . . . . . . . . . . . . 10-7
160, 162, 163 and 165 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-7
Power stud terminal blocks
162, 163 and 165 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-8
Power splicer blocks
160, 162, 163 and 165 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-8
Barrier terminal blocks
14002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-9
Dead front terminal blocks
14004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-9
10
Selection table for SCCR power distribution blocks and power terminal blocks
Control Panels. Marking the SCCR on Industrial Control
Panels (NEC 409.110), Industrial Machinery Electrical
Panels (NEC 607.3(A)), and HVAC equipment (NEC
440.4(B)) is required by the National Electrical Code. PDBs or
PTBs not marked with a SCCR, typically are the weakest link
and may limit an assembly to no more than 10kA SCCR. The
PDBFS and PDB have increased spacing required where
used in feeder circuits in equipment listed to UL508A
(UL1059 PTBs must be evaluated for proper spacings). Also,
for building wiring systems, the PDBFS and PDB power
distribution blocks can be used to meet the new 2013 NEC
requirements in section 376.56(B) for PDBs in wireways.
Selection table
Description
Catalog
page
High
Enclosed SCCR*
Spacing**
1 air
2 surface
UL
Series PDBFS
325
UL1953 Listed
Yes
Yes
Yes
Series PDB
326
UL 1953 Listed
No***
Yes
Yes
Industrial
control
panels
UL 508A
branch
circuit
Industrial
control
panels
UL 508A
feeder
circuit
Yes
Yes
Yes
Yes
Yes
Yes
HVAC
UL
1995
Spacing between
Spacing between
live parts of
live parts and
opposite polarity
grounded parts
or enclosure
Through air Over surface
@600V
@600V
@600V
8
3
8
3
2
1
2
1
Series PDB
2
2
1
1
Series PDBFS
1007July 2015
Eaton.com/bussmannseries
Wireways
NEC
376.56(B)
(requires
UL 1953)
Yes
Yes
w/optional
cover
10
Electrical
600Vac/dc (UL 1953), 690Vac/dc (IEC)
IP20 finger-safe under specific conditions
Short-circuit current ratings up to 200kA, see table
Ampacities up to 760 amps
Cu/Al wire range 14 AWG to 500 kcmil or 2.5 to 240 mm2
Mechanical
DIN-Rail or panel mount; PDBFS330 and PDBFS504 panel
mount only
Captive termination screws; screws do not get misplaced
Wire ready: captive termination screws shipped backed out
to save time on conductor installations
Sliding DIN-Rail latch for easy mounting
Single pole, gang mountable for multiple pole applications
with interlocking dovetail accessory (optional)
Flammability, UL 94V0
Tin-plated Al connectors suitable for Cu/Al conductors
Elongated hole for panel mounting; easier mounting with
greater flexibility in matching up with drilled panel holes
Part 2A1279: Interlocking dovetail pin accessory
One pin interlocks two units, two pins to interlock three units
DIN-Rail end anchors required to prevent damage to block
when torquing
Agency/standards
UL Listed 1953, Guide QPQS, File E256146
CSA Certified, Class 6228-01, File 47235
IEC 60947-7-1
IEC 60529, IP20 (finger-safe) under specific wiring
conditions
Series PDBFS
Terminal copper conductor capability
Line
Load
Configuration
Electrical
Catalog
number
(All Single
Pole)
Wire range
Wire range
Line
Load
Load
RK1
RK5
AWG or
kcmil
AWG or
kcmil
LPJ
JJS
JJN
LPS-RK
LPN-RK
FRS-R
FRN-R
2/0 to 8 200
200
100
60
200kA
4 to 12
200
175
200
200
175
200
100
100
100
60
30
60
200kA
100kA
50kA
350 to 6 400
400
200
100
200kA
4 to 8
4
4 to 14
400
200
175
600
400
200
400
200
175
600
400
200
200
100
100
400
200
100
100
60
30
200
100
60
200kA
50kA
100kA
200kA
100kA
50kA
500
600
800*
600
200
200kA
PDBFS204
2/0 to 8
PDBFS220
175A
2/0 to 14 AWG Cu
2/0 to 8 Al
2/0 to 8
PDBFS303
310A
350kcmil to
6 AWG Cu/Al
4 to 14 AWG Cu
4 to 8 AWG Al
PDBFS330
380A
PDBFS377
570A
PDBFS500
620A
350kcmil to
4 AWG Cu/Al
350kcmil to
4 AWG Cu/Al
PDBFS504
760A
500kcmil to
6 AWG Cu/Al
500kcmil to
6 AWG Cu/Al
NEC
350kcmil to
6 AWG Cu/Al
350 to 6
500kcmil to
6 AWG Cu/Al
2 to 14 AWG Cu
2 to 12 Al
500 to 6
300kcmil to
4 AWG Cu/Al
4 to 14 AWG Cu
4 to 12 Al
300
300 to 4
350 to 4
500
500 to 6
4 to 14
2 to 6
2 to 14
350 to 4 600
500 to 6 600
600
600
400
400
200
200
SCCR
200kA
100kA
1007July 2015
Eaton.com/bussmannseries
10-3
Power distribution
and terminal blocks
Feature/benefits
Enclosed, safer
installation; IP20
finger-safe under specific
conditions
High short-circuit current
ratings up to 200kA:
PDBs do not have to be
the weak link in achieving
high SCCR for an
industrial control panel
Small footprint saves
panel space
Listed to UL 1953 which has minimum spacing
requirements at 600V of at least 1 through air and 2 over
surface required for feeders in UL 508A Industrial Control
Panels
For 2D CAD drawings visit Eaton.com/bussmannseries
10
Electrical
600Vac/dc (UL 1953)
Short-circuit current ratings up to 200kA, see table
Wire range 14 AWG to 350 kcmil Cu/Al
Spacing between uninsulated opposite polarities or ground
meets UL 1953 which requires at least 1 through air and
2 over surface
Ratings available with circuit breakers
Mechanical
Panel mount
Flammability, UL 94V0
Tin-plated Al connectors suitable for Cu/Al conductors
Feature/benefits
High short-circuit current ratings up to 200kA. These
PDBs do not have to be the weak link in achieving high
SCCR for an industrial control panel
Listed to UL 1953 which has minimum spacing
requirements at 600V of at least 1 through air and 2 over
surface required for feeder in UL 508A Industrial Control
Panels
For 2D CAD drawings visit Eaton.com/bussmannseries
Optional covers
Covers are ordered for each individual pole, i.e., three
1-pole covers for 3-pole block, see table A.
Except PDB321 blocks have one cover for 1-, 2- or 3-pole
versions, see table B.
Table A
Table B
Block
Cover
Block
Cover
PDB2XX-(pole): CPB162-1
PDB321-1
CPDB-1
PDB3XX-(pole): CPDB-1
PDB321-2
CPDB-2
PDB321-3
CPDB-3
Agency/standards
UL Listed 1953, Guide QPQS, File E256146
Series PDB
Terminal copper conductor capability
Line
Load
Configuration
Catalog
number
Pole
Wire range
Wire range
Line
Load
Load
RK1
RK5
AWG or
kcmil
AWG or
kcmil
LPJ
JJS
JJN
LPS-RK
LPN-RK
FRS-R
FRN-R
2/0 - 8
2/0 - 8
200
200
200
60
200kA
4 - 12
200 200
175 175
200 200
200
100
100
60
60
60
200kA
100kA
50kA
Stud
200
200
100
60
200kA
400
400
14
175
400
4-8
400
10 - 12 175
4-8
400
400
10 - 14
175
1/0 - 6 400
400
8 - 12 175
400
400
175
400
400
175
400
400
175
400
400
175
200
400
100
200
400
100
200
400
100
200
400
100
100
100
60
100
100
60
100
100
60
100
100
60
200kA
100kA
100kA
200kA
100kA
100kA
200kA
100kA
100kA
200kA
100kA
100kA
PDB204-1
PDB204-3
175A
2/0 - 8 AWG Cu
2/0 - 12 AWG Al
2/0 - 8 AWG Cu
2/0 - 12 AWG Al
PDB220-1
PDB220-3
175A
2/0 - 8 AWG Cu
2/0 - 8 AWG Al
4 - 14 AWG Cu
4 - 8 AWG Al
2/0 - 8
PDB280-1
PDB280-3
175A
2/0 - 8 AWG Cu
2/0 - 8 AWG Al
2/0 - 8
175A
2/0 - 8 AWG Cu
2/0 - 12 AWG Al
4 - 14 AWG Cu
4 - 12 AWGAl
2/0 - 8
PDB323-1
PDB323-3
310A
350kcmil - 4 AWG Cu
350 - 6 AWG Al
4 - 12 AWG Cu
4 - 12 AWGAl
300 - 4
PDB370-1
PDB370-3
310A
350kcmil - 4 AWG Cu
350 - 4 AWG Al
4 - 14 AWG Cu
4 - 12 AWGAl
350 - 4
PDB371-1
PDB371-3
310A
350kcmil - 4 AWG Cu
350 - 6 AWG Al
PDB321-1
PDB321-2
PDB321-3
(6) 2 - 12 AWG Al
(6) (3)
2 - 1/0-12
12 AWG
(6)
- 8 AWGAlAl
(3)2 1/0-12
(3) 1/0-8 AWG Al
350 - 4
14
4 -12
Ampacities 75C per NEC Table 310.16 and UL508A Table 28.1
* Class G 60A (SC-60) or less or Class CC 30A (LP-CC-30, FNQ-R-30_SP, KTK-R-30) or less are suitable for all these SCCR in this table.
Higher SCCR may be available, check data sheet 1049.
1007July 2015
Eaton.com/bussmannseries
SCCR
10
163
Specifications
Power distribution
and terminal blocks
4.14"
Dimensions
1-pole
1.96"
2-pole
3.58"
3-pole
5.20"
2.10"
3.72"
5.34"
.31"
3.37"
4.00"
0.97"
1.62"
3.25"
3.32"
1007July 2015
Eaton.com/bussmannseries
10-5
10
Basic
catalog
numbers
Wire size
(poles) lineside
16303
16321**
Catalog numbers
16301*
16306
16323**
(poles) loadside
Amps/
pole
255
380
310
175
310
16325
350
16332
310
16335
16370**
310
16330
16371**
16372
16373
16375
16376
16377
16383
16378
16390
16395
16394
380
310
310
420
380
420
570
380
310
Ordering information
163 blocks are available in 1-, 2- or 3-poles. To order: basic catalog number + number of poles.
Examples:
16301-1 = one-pole block
16301-3 = three-pole block
10-6
380
1007July 2015
Eaton.com/bussmannseries
250
400
310
Line/load
11675
Catalog
numbers
11675-2
11675-3
11675-4
11675-5
11675-6
11675-7
Catalog numbers
Poles
2
3
4
5
6
7
Catalog
numbers
11675-8
11675-9
11675-10
11675-11
11675-12
Poles
8
9
10
11
12
11725
Description: Screw
connection line side, (4) 0.250"
quick-connect load side power
terminal block.
Poles: 2-, 3- or 4-poles.
Wire Range: 2 14 AWG
Cu/8 AWG Al.
Ratings:
Volts: 600Vac/dc
Amps: Up to 70A
SCCR: 10kA per UL 508A table SB4.1
Agency Information: CE, UL Guide XCFR2, E62622;
CSA 47235.
Torque Rating: 45 lb-in max.
Specifications
Catalog
Numbers
11725-2
11725-3
11725-4
Catalog Numbers
Poles
2
3
4
Specifications
Connector
Load
material &
Agency
connection
ampacity
information
(6)#4-#14Cu, #4-#8Al
175A
UL/CSA
(6)#4-#14Cu, #4-#12Al
310A
UL/CSA
(4)#4-#14Cu, #4-#8Al
175A
UL/CSA
(6)#4-#14Cu, #4-#8Al
175A
UL/CSA
(6)#4-#14Cu, #4-#12Al
310A
UL/CSA
(6)#4-#14Cu, #4-#8Al
350A
UL/CSA
(6)#2-#14Cu, #2-#12Al
380A
UL/CSA
(3)#2-#14Cu, #2-#8Al
310A
UL/CSA
(2)1/0-#14Cu, 1/0-#8Al
16335
500kcmil-#6Cu/Al
(3)#2-#14Cu, #2-#8Al
380A
UL/CSA
(2)1/0-#14Cu, 1/0-#8Al
16370** 350kcmil-#6Cu/Al
(12)#4-#14Cu, #4-#12Al 310A
UL/CSA
16371** 350kcmil-#6Cu/Al
(6)#2-#14Cu, #2-#8Al
310A
UL/CSA
(3)1/0-#14Cu, 1/0-#8Al
16372
350kcmil-#6Cu/Al
(21)#10-#14Cu, #10Al
310A
UL/CSA
16373
350kcmil-#6Cu/Al
(3)1/0-#14Cu/Al
310A
UL/CSA
(14)#10-#14Cu, #10Al
16375
600kcmil-#2Cu/Al
(12)#4-#14Cu, #4-#12Al 420A
UL/CSA
16376
600kcmil-#2Cu/Al
(6)#2-#14Cu, #2-#8Al
420A
UL/CSA
(3)1/0-#14Cu, 1/0-#8Al
16377
(2)300kcmil-#4Cu/Al
(12)#4-#14Cu, #4-#12Al 570A
UL/CSA
16400
(4)500kcmil-#6Cu/Al
(22)#2-#14Cu/Al
1520A
UL/CSA
16528
(2)600kcmil-#2Cu/Al
(4)3/0-#6Cu/Al
840A
UL/CSA
(4)#4-#14Cu/Al
16530
(2)500kcmil-#6Cu/Al
(12)#4-#14Cu/Al
760A
UL/CSA
16541
(1)500kcmil-#6Cu/Al
(21)#6-#14Cu/Al
380A
UL/CSA
*160 bases have mounting holes outside the barriers. Other bases (162 through 165) have
mounting holes within barriers. See Data Sheet for dimensional drawings.
**SCCR up to 200kA
Catalog numbers
Catalog Line
numbers connection
16021* 2/0-#14Cu, 2/0-#8Al
16023* 350kcmil-#6Cu/Al
16220** 2/0-#14Cu, 2/0-#8Al
16321** 2/0-#14Cu, 2/0-#8Al
16323** 350kcmil-#6Cu/Al
16325
(2)2/0-#14Cu, 2/0-#8Al
16330
500kcmil-#6Cu/Al
16332
350kcmil-#6Cu/Al
How to order
Catalog number + # of poles
Example: 16021 3 (complete part number)
160:
162:
163:
165:
CPB160 - (pole)
CPB162 - (pole)
CPDB- (pole)
CPDB165 (1 for each pole)
Optional covers:
1007July 2015
Eaton.com/bussmannseries
10-7
Power distribution
and terminal blocks
Description: Screw
connection line side, (3)
0.250" quick-connect
load side power
terminal block.
Poles:
2- to 12-poles.
Wire range:
8 14 AWG Cu.
Ratings:
Volts: 250Vac/dc
Amps: Up to 40A
SCCR: 10kA per UL 508A table SB4.1
Agency information: CE, Guide XCFR2, UL E62622;
CSA 47235.
Torque rating: 9 lb-in max.
Specifications
10
10
Specifications
Catalog
Line
numbers connection (poles)
Connector to stud
16280*
2/0-#14Cu-Al
16281
2/0-#14Cu-Al
16378
500kcmil-#6Cu-Al
16383
500kcmil-#6Cu-Al
16582
(2)500kcmil-#6Cu-Al
Stud to stud
1
16290
4-20 x 34 Stud
3
16390
8-16 x 118 Stud
3
16392
8-16 x 118 Stud
1
16394
2-13 x 1116 Stud
3
16395
8-16 x 1716 Stud
3
16591
8-16 x 1716 Stud
1
16593**
2-13 X 1 Stud
Load
connection (poles)
4-20 X 34 Stud
4-20 Tapped hole
(2)14-20 x 1 Stud
(1)38-16 x 1 Stud
(2)38-16 x 158 Stud
1
1
4-20 x 34 Stud
8-16 x 118 Stud
3
8-16 x 118 Stud
1
2-13 x 1116 Stud
(2)14-20 x 916 Stud
(2)38-16 x 1716 Stud
1
2-13 X 1 Stud
1
3
Material and
ampacity
Al-175A
Al-175A
Al-380A
Al-380A
Al-760A
Cu-175A
Cu-250A
Cu-400A
Cu-400A
Cu-310A
Cu-400A
Cu-600A
Connector
agency
information
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
CSA
CSA
CSA
CSA
CSA
CSA
CSA
CSA
CSA
How to order
Catalog number + # of poles
Example: 16000 3 (complete part number)
Description: Power
splicer terminal blocks.
Construction: Molded
black thermoplastic.
Wire range: See catalog
numbers table.
Poles: Series 160: 2-, 3- or 4-poles
Series 162, 163 and 165: 1-, 2- or 3-poles
Ratings:
Volts: 600Vac/dc
Amps: Up to 760A
SCCR: 10kA per UL 508A table SB4.1 (except for select
products noted in table)
Agency information: CE, Guide XCFR2, UL E62622
General Industrial Class per UL 1059; CSA Class 6228-01,
File 53787.
Flammability rating: UL 94V0.
Specifications
Connector
Catalog Line
Load
material and Agency
numbers connection
connection
ampacity
information
16000* 2/0-#8Cu/Al
2/0-#8Cu/Al
Al-175A
UL
16003* 250kcmil-#6Cu Only
250kcmil-#6Cu Only
Cu-255A
UL
16005* 350kcmil-#6Cu/Al
350kcmil-#6Cu/Al
Al-310A
UL
16200
#2-#14Cu, #2-#8Al
#2-#14Cu, #2-#8Al
Al-115A
UL
16201
1/0-#14Cu Only
1/0-#14Cu Only
Cu-150A
UL
16204** 2/0-#8Cu/Al
2/0-#8Cu/Al
Al-175A
UL
16301
250kcmil-#6Cu Only
250kcmil-#6Cu Only
Cu-255A
UL/CSA
16303
350kcmil-#6Cu/Al
350kcmil-#6Cu/Al
Al-310A
UL/CSA
16306
500kcmil-#6Cu/Al
500kcmil-#6Cu/Al
Al-380A
UL/CSA
16500
(2)350kcmil-#4Cu/Al
(2)350kcmil-#4Cu/Al
Al-620A
UL/CSA
16504
(2)500kcmil-#6Cu/Al
(2)500kcmil-#6Cu/Al
Al-760A
UL/CSA
*160 bases have mounting holes outside the barriers. Other bases (162 through 165) have
mounting holes within barriers. See Data Sheet for dimensional drawings.
**SCCR up to 200kA
Catalog numbers
How to order
Catalog number + # of poles
Example: 16000 3 (complete part number)
160:
162:
163:
165:
CPB160 - (pole)
CPB162 - (pole)
CPDB - (pole)
CPDB165 (1 for each pole) - new style
CPB165 - (pole) - old style
Optional covers:
Optional covers:
160:
162:
163:
165:
CPB160 - (pole)
CPB162 - (pole)
CPDB - (pole)
CPDB165 (1 for each pole) - new style
CPB165 - (pole) - old style
10-8
1007July 2015
Eaton.com/bussmannseries
10
14002
Description: Barrier
terminal block.
Poles: 2- to 6-poles.
Wire range: 2 14
AWG Cu/8 AWG Al.
Ratings:
Volts: 600Vac/dc
Amps: 115A
SCCR: 10kA per
UL 508A table SB4.1
Agency information: CE, Guide XCFR2, UL E62622;
CSA 47235.
Torque ratings*: 2-3, 50 lb-in; 4-6, 45 lb-in; 8, 40 lb-in;
10-14, 35 lb-in.
Specifications
Power distribution
and terminal blocks
Catalog
numbers
14002-2
14002-3
14002-4
Catalog numbers
Poles
2
3
4
Catalog
numbers
14002-5
14002-6
Poles
5
6
14004
Description: Dead
front terminal block.
Poles: 2- to 12-poles.
Wire range:
4 14 AWG Cu/
8 AWG Al.
Ratings:
Volts: 600Vac/dc
Amps: 90A
SCCR: 10kA per UL 508A table SB4.1
Agency information: CE, Guide XCFR2, UL E62622;
CSA 47235.
Marking: Marking strip optional, consult factory.
Specifications
Catalog
numbers
14004-2
14004-3
14004-4
14004-5
14004-6
14004-7
Catalog numbers
Poles
2
3
4
5
6
7
Catalog
numbers
14004-8
14004-9
14004-10
14004-11
14004-12
Poles
8
9
10
11
12
1007July 2015
Eaton.com/bussmannseries
10-9
DIN-Rail
terminal blocks
10-10
1007July 2015
Eaton.com/bussmannseries
Connectors
11
Contents
1007July 2015
Eaton.com/bussmannseries
11-1
Connectors
Description
Page
DIN-Rail terminal blocks
Feed through blocks (DS) . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-2
Feed through blocks (DP) . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-3
Mini feed through blocks (DM) . . . . . . . . . . . . . . . . . . . . . . . . 11-5
Double level blocks (DDP) . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-6
Disconnect blocks (DIS). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-6
Grounding blocks (DG) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-7
Fuse holder blocks (F520) . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-9
Internally jumpered blocks (DDNS). . . . . . . . . . . . . . . . . . . . 11-11
Test blocks (DTST2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-11
Panel mount blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12
Short-Circuit Current Ratings (SCCRs) . . . . . . . . . . . . . . . . 11-14
Accessories
Top screw-on bridges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-15
End brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-16
Partition plates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-16
Jumper slides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-17
Top insertion bridges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-17
Side insertion bridges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-18
Mounting rails and brackets. . . . . . . . . . . . . . . . . . . . . . . . . 11-20
BussScribe marking system
Marking system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-21
Marking labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-22
Compact blocks
Feed through blocks (NDN) . . . . . . . . . . . . . . . . . . . . . . . . . 11-25
Feed through blocks (C-Rail) . . . . . . . . . . . . . . . . . . . . . . . . 11-27
Depluggable blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-29
Multi-pole panel mount blocks. . . . . . . . . . . . . . . . . . . . . . . 11-31
Quick connect blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-32
Double row terminal blocks
TB100 2- to 36-pole blocks . . . . . . . . . . . . . . . . . . . . . . . .11-33
TB200 and TB200HB 2- to 30-pole blocks . . . . . . . . . . . . .11-35
TB300 and TB345 2- to 24-pole blocks . . . . . . . . . . . . . . 11-37
Marking options and covers for double row
series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-39
Top and bottom marking strips for terminal
blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-40
TB400 2- to 12-pole blocks . . . . . . . . . . . . . . . . . . . . . . . .11-41
KU 2- to 12-pole panel mount blocks . . . . . . . . . . . . . . . . .11-42
Power feed through terminal blocks
C7021 1- to 6-pole block . . . . . . . . . . . . . . . . . . . . . . . . . . 11-43
C7024 1- to 12-pole block . . . . . . . . . . . . . . . . . . . . . . . . . 11-44
Connectors
11
DS20
DS30
Approval
Approval
Technical Data
DS
The DS features a compact design
that saves wiring space on the
control panel. Accessories include
marking labels, partition plates as
well as side and top insertion
bridges. Designed for 35mm DIN
and 32mm G-Type rails.
IEC60947-7-1 and UL 1059
compliant.
UL
IEC
Rated voltage
600V
1000V
Rated current
20A
24A
End cover
Technical Data
Approval
IEC
UL
IEC
Rated voltage
600V
1000V
Rated voltage
600V
1000V
Rated current
30A
32A
Rated current
50A
41A
22~12 / 0.5~2.5
22~10 / 0.5~4
22~10 / 0.5~4
22~12 / 0.5~2.5
22~10 / 0.5~4
20~8 / 0.5~6
Rated impulse
withstand voltage
6kV
Rated impulse
withstand voltage
6kV
Rated impulse
withstand voltage
Torque(Nm)
0.4
Torque(Nm)
0.6
Torque(Nm)
1.2
Torque(lb-in)
3.5
Torque(lb-in)
5.3
Torque(lb-in)
10.6
M3
Screw
Screw
M2.5
Screw
9~11
WxHxD(mm)
9~11
6.1 x 39.6 x 40.3
8kV
M4
12~14
8 x 45 x 41.7
Colors
Cat. No.
Colors
Cat. No.
Colors
Cat. No.
Grey
DS20-GY
Grey
DS30-GY
Grey
DS50-GY
Blue
DS20-BU
Blue
DS30-BU
Blue
DS50-BU
Black
DS20-LK
Black
DS30-LK
Black
DS50-LK
Red
DS20-RD
Red
DS30-RD
Red
DS50-RD
Orange
DS20-OR
Orange
DS30-OR
Orange
DS50-OR
Yellow
DS20-YW
Yellow
DS30-YW
Yellow
DS50-YW
Green
DS20-GN
Green
DS30-GN
Green
DS50-GN
Accessories
Cat. No.
Accessories
Cat. No.
Accessories
Cat. No.
Grey
DS20-GY-ND
Grey
DS20-GY-ND
Grey
DS50-GY-ND
Blue
DS20-BU-ND
Blue
DS20-BU-ND
Blue
DS50-BU-ND
Black
DS20-LK-ND
Black
DS20-LK-ND
Black
DS50-LK-ND
Red
DS20-RD-ND
Red
DS20-RD-ND
Red
DS50-RD-ND
Orange
DS20-OR-ND
Orange
DS20-OR-ND
Orange
DS50-OR-ND
Yellow
DS20-YW-ND
Yellow
DS20-YW-ND
Yellow
DS50-YW-ND
Green
DS20-GN-ND
Green
DS20-GN-ND
Green
DS50-GN-ND
DKNSPS-001
Small partition
DKNSPS-001
DKNSPS-002
2-pole
3-pole
4-pole
10-pole
DSS2-5N-02P
DSS2-5N-03P
DSS2-5N-04P
DSS2-5N-10P
2-pole
3-pole
4-pole
10-pole
DSS4N-02P
DSS4N-03P
DSS4N-04P
DSS4N-10P
2-pole
3-pole
4-pole
10-pole
DSS6N-02P
DSS6N-03P
DSS6N-04P
DSS6N-10P
2-pole
3-pole
4-pole
10-pole
CSC-2-502PN
CSC-2-503PN
CSC-2-504PN
CSC-2-510PN
2-pole
3-pole
4-pole
10-pole
CSC-402PN
CSC-403PN
CSC-404PN
CSC-410PN
2-pole
3-pole
4-pole
10-pole
CSC-602PN
CSC-603PN
CSC-604PN
CSC-610PN
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
Marking label
Mounting Rail
TM26CB
TM27CB
TM28CB
DRL32MMG
DRL35MMHI
DRL35MMLO
DRL32MMG
DRL35MMHI
DRL35MMLO
DRL32MMG
DRL35MMHI
DRL35MMLO
Tool
11-2
Technical Data
UL
WxHxD(mm)
Block
DS50
1007July 2015
Eaton.com/bussmannseries
Connectors
11
DP25
DP35
Approval
Technical Data
DP
Block
End cover
IEC
Technical Data
Rated voltage
600V
630V
Rated current
25A
24A
Approval
UL
IEC
Technical Data
UL
IEC
Rated voltage
600V
630V
Rated voltage
600V
500V
Rated current
35A
32A
Rated current
45A
41A
20~8 / 0.5~6
20~8 / 0.5~6
22~12 / 0.5~2.5
22~10 / 0.5~4
22~12 / 0.5~2.5
22~10 / 0.5~4
Rated impulse
withstand voltage
8kV
Rated impulse
withstand voltage
8kV
Rated impulse
withstand voltage
Torque(Nm)
0.8
Torque(Nm)
0.8
Torque(Nm)
1.8
Torque(lb-in)
7.1
Torque(lb-in)
7.1
Torque(lb-in)
15.9
M3
Screw
M3
Screw
Screw
Wire strip length(mm)
WxHxD(mm)
10~12
5.1 x 47.6 x 58.9
10~12
WxHxD(mm)
8kV
M4
12~14
8 x 47.6 x 58.9
Colors
Cat. No.
Colors
Cat. No.
Colors
Cat. No.
Grey
DP25-GY
Grey
DP35-GY
Grey
DP45-GY
Blue
DP25-BU
Blue
DP35-BU
Blue
DP45-BU
Black
DP25-LK
Black
DP35-LK
Black
DP45-LK
Red
DP25-RD
Red
DP35-RD
Red
DP45-RD
Orange
DP25-OR
Orange
DP35-OR
Orange
DP45-OR
Yellow
DP25-YW
Yellow
DP35-YW
Yellow
DP45-YW
Green
DP25-GN
Green
DP35-GN
Green
DP45-GN
Accessories
Cat. No.
Accessories
Cat. No.
Accessories
Cat. No.
Grey
DP25-GY-ND
Grey
DP25-GY-ND
Grey
DP25-GY-ND
Blue
DP25-BU-ND
Blue
DP25-BU-ND
Blue
DP25-BU-ND
Black
DP25-LK-ND
Black
DP25-LK-ND
Black
DP25-LK-ND
Red
DP25-RD-ND
Red
DP25-RD-ND
Red
DP25-RD-ND
Orange
DP25-OR-ND
Orange
DP25-OR-ND
Orange
DP25-OR-ND
Yellow
DP25-YW-ND
Yellow
DP25-YW-ND
Yellow
DP25-YW-ND
Green
DP25-GN-ND
Green
DP25-GN-ND
Green
DP25-GN-ND
Partition
DKSPS-001
DKSPS-001
DKSPS-002
Small partition
DKSPS-001
DKSPS-002
DKSPS-002
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
CSC-2-502P
CSC-2-503P
CSC-2-504P
CSC-2-510P
2-pole
3-pole
4-pole
10-pole
CSC-402P
CSC-303P
CSC-404P
CSC-410P
2-pole
3-pole
4-pole
10-pole
CSC-602P
CSC-603P
CSC-604P
CSC-610P
2-pole
3-pole
4-pole
10-pole
DS2-5-02P
DS2-5-03P
DS2-5-04P
DS2-5-10P
2-pole
3-pole
4-pole
10-pole
DS4-02P
DS4-03P
DS4-04P
DS4-10P
2-pole
3-pole
4-pole
10-pole
DS6-02P
DS6-03P
DS6-04P
DS6-10P
Marking label
Mounting Rail
Tool
TM26CB
TM27CB
TM28CB
DRL32MMG
DRL35MMHI
DRL35MMLO
DRL32MMG
DRL35MMHI
DRL35MMLO
DRL32MMG
DRL35MMHI
DRL35MMLO
0.4 x 2.5mm
0.5 x 3mm
0.8 x 4mm
1007July 2015
Connectors
Approval
UL
DP45
Eaton.com/bussmannseries
11-3
Connectors
11
DP60
DP100
Approval
Technical Data
DP150
Approval
UL
IEC
Technical Data
Rated voltage
600V
500V
Rated current
60A
57A
Approval
UL
IEC
Rated voltage
600V
1000V
Rated current
100A
101A
20~6 / 1.5~10
20~6 / 1.5~10
Rated impulse
withstand voltage
Approval
Technical Data
IEC
UL
IEC
Rated voltage
600V
1000V
Rated voltage
600V
1000V
Rated current
150A
150A
Rated current
230A
232A
14~3 / 1.5~25
14~3 / 1.5~25
8kV
Rated impulse
withstand voltage
Torque(Nm)
1.8
Torque(lb-in)
15.9
Screw
M4
12~14
10 x 47.6 x 58.9
12~1/0 / 2.5~50
2 / 35
12~1/0 / 2.5~50
2~4/0 / 35~95
8kV
Rated impulse
withstand voltage
8kV
Rated impulse
withstand voltage
8kV
Torque(Nm)
3.4
Torque(Nm)
6.9
Torque(Nm)
10.2
Torque(lb-in)
30.1
Torque(lb-in)
61.1
Torque(lb-in)
90.3
Screw
M5
Screw
M6
Screw
M8
Colors
Cat. No.
Colors
Grey
DP60-GY
Grey
Accessories
Grey
Cat. No.
DP25-GY-ND
Technical Data
UL
DP230
Accessories
Grey
DKSPS-001
13~15
12 x 52.2 x 46.7
Cat. No.
DP100-GY
Cat. No.
16~18
16 x 61.2 x 52
Cat. No.
30~35
25 x 88.5 x 80
Cat. No.
Grey
DP150-GY
Grey
DP230-GY
Blue
DP150-BU
Blue
DP230-BU
Accessories
Cat. No.
Accessories
Cat. No.
DP100-GY-ND
DKNSPS-004
DKNSPS-003
DKNSPS-004
DKSPS-002
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
CSC-1002P
CSC-1003P
CSC-1004P
CSC-1010P
2-pole
3-pole
4-pole
10-pole
CSC-1602P
CSC-1603P
CSC-1604P
CSC-1610P
2-pole
3-pole
4-pole
10-pole
CSC-3502P
CSC-3503P
CSC-3504P
CSC-3510P
2-pole
3-pole
4-pole
10-pole
CSC-9502P
CSC-9503P
N/A
CSC-N/A510P
2-pole
3-pole
4-pole
10-pole
DS10-02P
DS10-03P
DS10-04P
DS10-10P
2-pole
3-pole
4-pole
10-pole
DS16-02P
DS16-03P
DS16-04P
DS16-10P
2-pole
3-pole
4-pole
10-pole
DS35-02P
DS35-03P
DS35-04P
DS35-10P
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
11-4
TM28CB
TM28CB
TM28CB
TM28CB
DRL32MMG
DRL35MMHI
DRL35MMLO
DRL32MMG
DRL35MMHI
DRL35MMLO
DRL32MMG
DRL35MMHI
DRL35MMLO
DRL32MMG
DRL35MMHI
DRL35MMLO
0.8 x 4mm
1.0 x 5.5mm
1007July 2015
Eaton.com/bussmannseries
Connectors
11
DM20
DM30
Approval
Technical Data
IEC
Rated voltage
300V
500V
Rated current
20A
24A
Approval
Technical Data
Technical Data
UL
IEC
UL
IEC
Rated voltage
300V
500V
Rated voltage
300V
500V
Rated current
30A
32A
Rated current
50A
41A
22~12 / 0.5~2.5
22~10 / 0.5~4
20~8 / 0.5~6
22~12 / 0.5~2.5
22~10 / 0.5~4
20~8 / 0.5~6
Rated impulse
withstand voltage
5kV
Rated impulse
withstand voltage
5kV
Rated impulse
withstand voltage
6kV
Torque(Nm)
0.4
Torque(Nm)
0.6
Torque(Nm)
1.2
3.5
10.6
Torque(lb-in)
5.3
Torque(lb-in)
Screw
M2.5
Screw
M3
Screw
7~9
7~9
WxHxD(mm)
5.1 x 28 x 22
WxHxD(mm)
6.1 x 31.5 x 22
WxHxD(mm)
M4
9~11
8 x 37.4 x 30
Colors
Cat. No.
Colors
Cat. No.
Colors
Cat. No.
Grey
DM20-GY
Grey
DM30-GY
Grey
DM50-GY
Blue
DM20-BU
Blue
DM30-BU
Blue
DM50-BU
Black
DM20-LK
Black
DM30-LK
Black
DM50-LK
Accessories
End cover
Approval
UL
Torque(lb-in)
Block
DM50
Cat. No.
Accessories
Connectors
DM
Cat. No.
Accessories
Cat. No.
Grey
DM20-GY-ND
Grey
DM30-GY-ND
Grey
DM50-GY-ND
Blue
DM20-BU-ND
Blue
DM30-BU-ND
Blue
DM50-BU-ND
Black
DM20-LK-ND
Black
DM30-LK-ND
Black
DM50-LK-ND
Partition
Small partition
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
CSC-2-502PS
CSC-2-503PS
CSC-2-504PS
CSC-2-510PS
2-pole
3-pole
4-pole
10-pole
CSC-402PS
CSC-303PS
CSC-404PS
CSC-410PS
2-pole
3-pole
4-pole
10-pole
CSC-602PS
CSC-603PS
CSC-604PS
CSC-610PS
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
Marking label
Mounting Rail
TM20CB
TM21CB
TM22CB
DRL15MM
DRL15MM
DRL15MM
Tool
1007July 2015
Eaton.com/bussmannseries
11-5
Connectors
11
DDP30
DDP
Approval
Technical Data
UL
IEC
Rated voltage
300V
400V
Rated current
30A
32A
22~10 / 0.5~4
22~10 / 0.5~4
Rated impulse
withstand voltage
Approval
Technical Data
UL
IEC
Rated voltage
300V
800V
Rated current
10A
16A
26~14 / 0.5~2.5
26~14 / 0.5~2.5
6kV
Rated impulse
withstand voltage
6kV
Torque(Nm)
0.5
Torque(Nm)
0.8
Torque(lb-in)
4.4
Torque(lb-in)
7.1
Screw
WxHxD(mm)
M2.5
Screw
Colors
Grey
WxHxD(mm)
Cat. No.
DDP30-GY
M3
9~10
5.1 x 46.7 x 59
Colors
Cat. No.
Grey
DIS10-GY
Block
Block
Accessories
Grey
End cover
Cat. No.
DDP30-GY-ND
Partition
Accessories
End cover
Grey
Partition
Small partition
DKSPS-002
Small partition
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
CSC-402P
CSC-403P
CSC-404P
CSC-410P
2-pole
3-pole
4-pole
10-pole
CSC-2-502P
CSC-2-503P
CSC-2-504P
CSC-2-510P
2-pole
3-pole
4-pole
10-pole
DS4-02P
DS4-03P
DS4-04P
DS4-10P
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
TM21CB
Marking label
Marking label
Mounting Rail
Tool
11-6
DIS10
DIS
DRL32MMG
DRL35MMHI
DRL35MMLO
0.4 x 2.5mm
1007July 2015
Mounting Rail
Tool
Eaton.com/bussmannseries
TM26CB
DRL32MMG
DRL35MMHI
DRL35MMLO
0.5 x 3mm
Connectors
11
Grounding blocks
DG25
DG35
Approval
Technical Data
Rated voltage
Approval
UL
IEC
Technical Data
600V
630V
Rated voltage
24A
Rated current
Rated current
Conductor crosssection, solid
(AWG/mm2)
DG60
26~12 / 0.5~2.5
26~12 / 0.5~2.5
Rated impulse
withstand voltage
Approval
UL
IEC
Technical Data
600V
630V
Rated voltage
32A
Rated current
UL
IEC
600V
500V
57A
26~10 / 0.5~4
16~8 / 1.5~10
26~10 / 0.5~4
16~8 / 1.5~10
8kV
Rated impulse
withstand voltage
8kV
Rated impulse
withstand voltage
8kV
Torque(Nm)
0.8
Torque(Nm)
0.8
Torque(Nm)
1.8
Torque(lb-in)
7.1
Torque(lb-in)
7.1
Torque(lb-in)
15.9
Screw
M3
Screw
M3
Screw
10~14
5.7 x 46.4 x 56
Cat. No.
DG25-YG
Connectors
DG
12~16
6.6 x 46.4 x 56
Cat. No.
WxHxD(mm)
Colors
DG35-YG
Yellow-Green
M4
12~16
10.4 x 46.4 x 56
Cat. No.
DG60-YG
Block
Accessories
Cat. No.
Accessories
Cat. No.
Accessories
Cat. No.
End cover
Partition
Small partition
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
Marking label
Mounting Rail
Tool
TM26CB
TM27CB
TM28CB
DRL32MMG
DRL35MMHI
DRL35MMLO
DRL32MMG
DRL35MMHI
DRL35MMLO
DRL32MMG
DRL35MMHI
DRL35MMLO
0.5 x 3mm
0.5 x 3mm
0.8 x 4mm
1007July 2015
Eaton.com/bussmannseries
11-7
Connectors
11
Grounding blocks
DG100
DG230
DG150
Approval
Approval
Approval
Technical Data
UL
IEC
Technical Data
UL
IEC
Technical Data
UL
IEC
Rated voltage
600V
1000V
Rated voltage
600V
1000V
Rated voltage
600V
1000V
76A
Rated current
125A
Rated current
Rated current
Conductor crosssection, solid
(AWG/mm2)
14~6 / 2.5~16
14~6 / 2.5~16
Rated impulse
withstand voltage
232A
12~2 / 4~35
2 / 35
12~2 / 4~35
2~4/0 / 35~95
8kV
Rated impulse
withstand voltage
8kV
Rated impulse
withstand voltage
8kV
Torque(Nm)
3.4
Torque(Nm)
5.6
Torque(Nm)
18
Torque(lb-in)
30.1
Torque(lb-in)
49.6
Torque(lb-in)
159.3
M5
Screw
M6
Screw
Screw
Wire strip length(mm)
WxHxD(mm)
Colors
Yellow-Green
Accessories
14~18
12 x 62.4 x 56
Cat. No.
DG100-YG
Cat. No.
Accessories
14~18
16 x 62.4 x 56
Cat. No.
DG150-YG
Cat. No.
M8
20~25
25 x 82.93 x 80
Cat. No.
Yellow-Green
Accessories
DG230-YG
Cat. No.
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
11-8
TM28CB
TM28CB
TM28CB
DRL32MMG
DRL35MMHI
DRL35MMLO
DRL32MMG
DRL35MMHI
DRL35MMLO
DRL32MMG
DRL35MMHI
DRL35MMLO
1.0 x 5.5mm
1.0 x 5.5mm
1007July 2015
Eaton.com/bussmannseries
Connectors
11
F520STLED
Approval
Technical Data
Rated voltage
Rated current
IEC
300V
300V
6.3A
6.3A
Approval
Technical Data
Rated voltage
Rated current
UL
IEC
300V
300V
6.3A
6.3A
Technical Data
Rated voltage
Rated current
UL
IEC
300V 1)
300V
16A 2)
16A 2)
30A 3)
30A 3)
24~12 / 0.5~4
24~12 / 0.5~4
22~10 / 0.5~4
24~12 / 0.5~4
24~12 / 0.5~4
22~10 / 0.5~4
Rated impulse
withstand voltage
6kV
Rated impulse
withstand voltage
6kV
Rated impulse
withstand voltage
6kV
Torque(Nm)
0.8
Torque(Nm)
0.8
Torque(Nm)
0.67
Torque(lb-in)
7.1
Torque(lb-in)
7.1
Torque(lb-in)
Screw
M3
Screw
M3
Screw
WxHxD(mm)
Colors
Grey
Accessories
Grey
End cover
Approval
UL
Block
F520DDST
10~12
8 x 55.7 x 56
Cat. No.
F520ST-GY
Cat. No.
F520-GY-ND
Partition
10~12
Voltage
5.9
M3.5
8 x 55.7 x 56
WxHxD(mm)
5V
F520STLED5-GY
Grey
12V
F520STLED12-GY
Grey
24V
F520STLED24-GY
Grey
48V
F520STLED48-GY
Grey
110V
F520STLED110-GY
Grey
220V
F520STLED220-GY
Grey
300V
F520STLED300-GY
10~12
8 x 60.5 x 72.5
Colors
Cat. No.
Grey
Accessories
Small partition
Cat. No.
Grey
F520DDST-GY
1) UL 600V / 5A
2) upper level 3) lower level
Accessories
Grey
Cat. No.
F520DD-GY-ND
Cat. No.
F520-GY-ND
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
CSC-602PN
CSC-603PN
CSC-604PN
CSC-610PN
2-pole
3-pole
4-pole
10-pole
CSC-602PN
CSC-603PN
CSC-604PN
CSC-610PN
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
Marking label
Mounting Rail
Tool
TM28CB
TM28CB
TM28CB
DRL32MMG
DRL35MMHI
DRL35MMLO
DRL32MMG
DRL35MMHI
DRL35MMLO
DRL32MMG
DRL35MMHI
DRL35MMLO
0.5 x 3mm
0.5 x 3mm
0.5 x 3mm
Connectors
F520ST
F520
1007July 2015
Eaton.com/bussmannseries
11-9
Connectors
11
F520TOP
Approval
Technical Data
UL
IEC
Rated voltage
600V
660V
6.3A
6.3A
Rated current
Conductor crosssection, solid
(AWG/mm2)
22~6 / 1.5~10
22~6 / 1.5~10
Rated impulse
withstand voltage
6kV
Torque(Nm)
1.8
Torque(lb-in)
15.9
Screw
Wire strip length(mm)
WxHxD(mm)
Colors
Grey
Accessories
M4
12~16
12 x 47.2 x 61.6
Cat. No.
F520T0P-GY
Cat. No.
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
2-pole
3-pole
4-pole
10-pole
N/A
N/A
N/A
N/A
TM20CB
DRL32MMG
DRL35MMHI
DRL35MMLO
0.6 x 3.5mm
11-10
1007July 2015
Eaton.com/bussmannseries
Connectors
11
DDNS10
Approval
Technical Data
DTST2
DTST2
UL
IEC
Rated voltage
300V
630V
Rated current
10A
17.5A
Approval
Technical Data
UL
IEC
Rated voltage
300V/600V
660V
Rated current
48A/5A
41A
22~14 / 0.5~1.5
20~8 / 0.5~6
22~14 / 0.5~1.5
20~8 / 0.5~6
Rated impulse
withstand voltage
8kV
Rated impulse
withstand voltage
6kV
Torque(Nm)
0.4
Torque(Nm)
3.5
Torque(lb-in)
17.7
Screw
M2.5
Screw
M4
6~7
Torque(lb-in)
WxHxD(mm)
Colors
Grey
WxHxD(mm)
Colors
Cat. No.
Grey
DDNS10-GY
Accessories
Block
Grey
End cover
Accessories
Grey
End cover
Cat. No.
2-pole
3-pole
Jumper Slide
DS6S1-BK
DS6S1-OR
DS6S1-YW
DS6S1-RD
Connection Sleeve
C002-0201
Small partition
Marking label
Mounting Rail
Tool
2-pole
3-pole
4-pole
10-pole
CSC-2-502P
CSC-2-503P
CSC-2-504P
CSC-2-510P
2-pole
3-pole
4-pole
10-pole
DS2-5-02P
DS2-5-03P
DS2-5-04P
DS2-5-10P
DS6A02
DS6A03
Screw
Partition
N/A
N/A
N/A
N/A
Cat. No.
DTST-GY-ND
C002-0101-BK
C002-0101-RD
Test Plug
2-pole
3-pole
4-pole
10-pole
DKSPS-006
Partition
DDNS10-GY-ND
8
8 x 65.6 x 47.5
C002-0301
Connection Socket
TM26CB
DRL32MMG
DRL35MMHI
DRL35MMLO
0.4 x 2.5mm
Marking label
2-pole
3-pole
4-pole
10-pole
CSC-602P
CSC-603P
CSC-604P
CSC-610P
2-pole
3-pole
4-pole
10-pole
DS6-02P
DS6-03P
DS6-04P
DS6-10P
DRL32MMG
DRL35MMHI
DRL35MMLO
Mounting Rail
0.6 x 3.5mm
Tool
1007July 2015
TM28CB
Eaton.com/bussmannseries
11-11
Connectors
DDNS
Connectors
11
P20S
Panel mount
P30S
Approval
P65S
Approval
Technical Data
Technical Data
Approval
UL
IEC
UL
IEC
Rated voltage
300V
500V
Rated voltage
300V
500V
Rated current
20A
24A
Rated current
30A
32A
Technical Data
UL
IEC
Rated voltage
300V
500V
41A
Rated current
65A
22~10 / 0.5~4
20~6 / 1.5~10
22~10 / 0.5~4
20~6 / 1.5~10
7kV
Rated impulse
withstand voltage
7kV
Rated impulse
withstand voltage
8kV
Torque(Nm)
0.39
Torque(Nm)
0.49
Torque(Nm)
1.18
Torque(lb-in)
3.5
Torque(lb-in)
4.3
Torque(lb-in)
10.4
M2.5
Screw
M3
Screw
M4
6~8
6~8
22~12 / 0.5~2.5
22~12 / 0.5~2.5
Rated impulse
withstand voltage
Screw
Wire strip length(mm)
WxHxD(mm)
5.1 x 20 x 22
Colors
Cat. No.
Grey
WxHxD(mm)
Colors
P20S-GY-01
Grey
6.1 x 22 x 23
Cat. No.
P30S-GY-01
WxHxD(mm)
Colors
Grey
9~11
8 x 29.8 x 30
Cat. No.
P65S-GY-01
Block
Accessories
Cat. No.
Accessories
Cat. No.
Accessories
Grey
P20S-GY-ND
Grey
P30S-GY-ND
Grey
P65S-GY-ND
2-pole
3-pole
4-pole
10-pole
CSC-2-502PS
CSC-2-503PS
CSC-2-504PS
CSC-2-510PS
2-pole
3-pole
4-pole
10-pole
CSC-402PS
CSC-403PS
CSC-404PS
CSC-410PS
2-pole
3-pole
4-pole
10-pole
CSC-602PS
CSC-603PS
CSC-604PS
CSC-610PS
Marking label
TM20CB
TM21CB
TM22CB
Tool
Dimensions - mm
11-12
Cat. No.
End cover
Dimensions - mm
1007July 2015
Eaton.com/bussmannseries
Dimensions - mm
Connectors
Panel mount blocks
P25G
2P25G
Approval
UL
IEC
Technical Data
UL
IEC
Rated voltage
600V
660V
Rated voltage
600V
660V
Rated current
25A
24A
Rated current
25A
24A
28~12 / 0.5~2.5
28~12 / 0.5~2.5
14~12 / 0.5~2.5
14~12 / 0.5~2.5
Rated impulse
withstand voltage
8kV
Rated impulse
withstand voltage
8kV
Torque(Nm)
Spring Clamp
Torque(Nm)
Spring Clamp
Torque(lb-in)
Spring Clamp
Torque(lb-in)
Spring Clamp
Screw
Wire strip length(mm)
WxHxD(mm)
Colors
Grey
Accessories
Grey
2-pole
3-pole
4-pole
10-pole
Connectors
Approval
Technical Data
11
N/A
Screw
7~8
6 x 28 x 18
Cat. No.
P25G-GY-01
Cat. No.
P25G-GY-ND
DS-204
N/A
N/A
N/A
N/A
WxHxD(mm)
Colors
Cat. No.
Grey
2P25G-GY-01
Accessories
Grey
2-pole
3-pole
4-pole
10-pole
7~8
10 x 28 x 18
Cat. No.
P25G-GY-ND
DS-204
N/A
N/A
N/A
TM20CB
TM20CB
0.4 x 2.5mm
0.4 x 2.5mm
1007July 2015
Eaton.com/bussmannseries
11-13
11
Description
Connectors
Short-Circuit Current Ratings (SCCRs)
Part number*
Volts
Amps
SCCR level
RK5
RK1
J/CF
Fuse Class
T
G
CC
Terminal block
DS20-XX
600
20
12-14
100kA
30
60
60
60
30
Terminal block
DS30-XX
600
30
10-18
100kA
30
60
60
60
30
Terminal block
DS50-XX
600
50
8 - 18
100kA
30
60
60
60
30
Terminal block
DM20-XX
300
20
12 - 16
100kA
30
60
60
60
30
Terminal block
DM30-XX
300
30
10 - 16
100kA
30
60
60
60
30
Terminal block
DM50-XX
300
50
8 - 16
100kA
30
60
60
60
30
Terminal block
DP25-XX
600
25
12 - 18
100kA
30
60
60
60
30
Terminal block
DP35-XX
600
35
10 - 18
100kA
30
60
60
60
30
Terminal block
DP45-XX
600
45
8 - 18
100kA
30
60
60
60
30
Terminal block
DP60-XX
600
60
6 - 18
100kA
30
60
60
60
30
Terminal block
DP100-XX
600
100
14-3
200kA
30
60
100
100
60
30
Terminal block
DP150-XX
600
150
1/0 - 12
100kA
30
100
200
200
60
30
Terminal block
DP230-XX
600
230
2-4/0
200kA
60
100
200
200
60
30
Terminal block
DP370-XX
600
370
300 - 500kcmil
200kA
100
200
400
400
60
30
Grounding block
DG25-XX
600
12 - 18
100kA
30
60
60
60
30
Grounding block
DG35-XX
600
10 - 16
100kA
30
30
60
60
60
30
Grounding block
DG60-XX
600
16-8
200kA
30
60
100
100
60
30
Grounding block
DG100-XX
600
14-6
200kA
60
100
100
60
30
Grounding block
DG150-XX
600
12-2
200kA
30
60
100
100
60
30
Grounding block
DG230-XX
600
2-4/0
200kA
30
60
100
100
60
30
Terminal block
DDP30-XX (upper)
300
30
10 - 18
100kA
30
60
60
60
30
Terminal block
DDP30-XX (lower)
300
30
10 - 18
100kA
30
60
60
60
30
Terminal block
DDNS10-XX
300
10
16 - 18
100kA
30
60
60
60
30
Terminal block
DIS10-XX
300
10
16 - 16
100kA
30
60
60
60
30
F520ST-XX
300
6.3
18 - 18
100kA
30
60
60
60
30
F520STLED-XX
300
6.3
18 - 18
100kA
30
60
60
60
30
F520DDST-XX (upper)
300
16
10 - 18
100kA
30
60
60
60
30
F520DDST-XX (lower)
300
30
10 - 18
100kA
30
60
60
60
30
F520TOP-XX
600
6.3
6 - 18
100kA
30
60
60
60
30
Terminal block
DTST2-XX
300/600
48/5
8 - 20
100kA
30
60
60
60
30
Terminal block
P20S-XX
300
20
12 - 16
100kA
30
60
60
60
30
Terminal block
P30S-XX
300
30
10 - 16
100kA
30
60
60
60
30
Terminal block
P65S-XX
300
65
6 - 16
100kA
30
60
60
60
30
Terminal block
P25G-XX
600
25
12 - 14
100kA
30
60
60
60
30
Terminal block
2P25G-XX
600
25
12 - 14
100kA
30
60
60
60
30
11-14
1007July 2015
Eaton.com/bussmannseries
Connectors
Accessories
11
Use with
DS4-XXP
DG25
Use with
DP35
DDP30
Use with
DS10-XXP
DP45
DTST2
Use with
DP60
Dimensions - mm
Dimensions - mm
Dimensions - mm
Dimensions - mm
DS16 - XXP
DS35 - XXP
Use with
DP100
Use with
Connectors
DP25
DDNS10
DS6-XXP
DP150
Dimensions - mm
in (mm)
Dimensions - mm
in (mm)
1007July 2015
Eaton.com/bussmannseries
11-15
Connectors
11
Accessories
End brackets
BRKT-ND
BRKT-NDSCRW
BRKT-NDSCRW2
BRKT-NDSCRW3
Use with
DRL35MMHI
Use with
DRL35MMHI
Use with
DRL35MMHI
Use with
DRL35MMHI
Torque(Nm)
DRL35MMLO
N/A
Torque(Nm)
DRL35MMLO
0.5
Torque(Nm)
DRL35MMLO
0.78
Torque(Nm)
DRL35MMLO
1.8
Torque(lb-in)
N/A
Torque(lb-in)
4.4
Torque(lb-in)
6.9
Torque(lb-in)
15.9
Screw
N/A
Screw
M3
Screw
M3
Screw
M4
Dimensions - mm
Dimensions - mm
Dimensions - mm
DKSPS-002
DKSPS-006
Dimensions - mm
Partition plates
DKSPS-001
Use with
DP25
DP35
DP45
DP60
Use with
DP25
DP45
DP35
DP60
Use with
DTST2
DIS10
DKNSPS-001
Use with
11-16
DS20
DS30
DKNSPS-002
DKNSPS-003
DKNSPS-004
Use with
Use with
Use with
DS50
1007July 2015
DP100
Eaton.com/bussmannseries
DP150
Connectors
Accessories
11
Jumper slides
DS6A02
Use with
DTST2
02
Dimensions - mm
Use with
DTST2
Poles
Connectors
Poles
DS6A03
03
Dimensions - mm
Use with
DSS4N-XXP
DS20
DSS6N-XXP
Use with
DS30
Use with
DS50
Dimensions - mm
Dimensions - mm
1007July 2015
Eaton.com/bussmannseries
11-17
Connectors
11
Accessories
Use with
CSC-4XXP
DP25
DIS10
Use with
P20S
CSC-6XXP
DP35
DDP30
CSC-10XXP
Use with
DTST2
DP45
Use with
DP60
DDNS10
Poles (XX) 02, 03, 04, 10
Dimensions - mm
Dimensions - mm
Dimensions - mm
Dimensions - mm
CSC-16XXP
CSC-35XXP
CSC-95XXP
CSC-2-5XXPN
Use with
DP100
Use with
DP150
Use with
DP230
Use with
DS20
Dimensions - mm
Dimensions - mm
Dimensions - mm
Dimensions - mm
11-18
1007July 2015
Eaton.com/bussmannseries
Connectors
Accessories
11
Use with
CSC-6XXPN
DS30
Use with
DS-204
DS50
Use with
CSC-2-5XXPS
P25G
Use with
DM20
Poles 02
Dimensions - mm
Dimensions - mm
Dimensions - mm
Dimensions - mm
CSC-4XXPS
CSC-6XXPS
Use with
DM30
P30S
Use with
Connectors
P20S
2P25G
DM50
P65S
Dimensions - mm
Dimensions - mm
1007July 2015
Eaton.com/bussmannseries
11-19
11
Connectors
Accessories
DRL32MMG*
DRL35MMLO*
DRL35MMHI*
(15mm DIN-Rail)
(32mm G-Type)
NFTA Series**
NRA Series**
BRKT-ANGL
BRKT-FLT
(C-Rail)
(C-Rail)
(Angle Bracket)
(Flat Bracket)
*Available in
only.
*Available
in 11meter
meterlengths
lengths
only.
**Cut to length.
Bussmann
for details.
**Cut
length.Consult
ConsultCooper
Eatons
Bussmann
Division for details.
11-20
1007July 2015
Eaton.com/bussmannseries
Connectors
BussScribe marking system
DPLT-001SET
DPLT-SPLT
PLOTTER PENS
Plotter set
Support plate
11
Connectors
Description
Description
Description
USB interface to PC
label series.
Plotter pens
Support plate
Software
Plotter
Power supplies
USB Cable
Length (mm)
Width (mm)
Line x row
Number of tags
TM20CB
5.8
5.1
20 x 10
200
F20T0P,
DM20,
P20S, P25G, 2P25G
TM21CB
5.8
6.1
20 x 10
200
DDP30,
DM30,
P30S
TM22CB
5.8
8.0
20 x 8
160
DM50,
P65S
TM26CB
12
5.1
12 x 12
144
DS20,
DP25,
DG25,
DDNS10,
DIS10
TM27CB
12
6.1
12 x 10
120
DS30,
DP35,
DG35
84
DS50,
DP45, DP60, DP100, DP150, DP230,
DG60, DG100, DG150, DG230,
F520ST, F520STLED, F520DDST,
DTST2
TM28CB
12
8.0
12 x 7
1007July 2015
Eaton.com/bussmannseries
11-21
11
Connectors
Marking label ordering method (typical)
TM20CB - mm
TM20CB
TM21CB
Part numbers
Descriptions
Part numbers
Descriptions
TM20CB
TM21CB
TM20CB-DH01
TM21CB-DH01
TM20CB-DH02
TM21CB-DH02
TM20CB-FH01
TM21CB-FH01
TM20CB-FH0
TM21CB-FH02
TM20CB-FH03
TM21CB-FH03
TM20CB-FH04
TM21CB-FH04
TM20CB-FH05
TM21CB-FH05
TM20CB-EH01
TM21CB-EH01
TM20CB-EH02
TM21CB-EH02
TM20CB-DV01
TM21CB-DV01
TM20CB-DV02
TM21CB-DV02
TM20CB-FV01
TM21CB-FV01
TM20CB-FV02
TM21CB-FV02
TM20CB-EV01
TM21CB-EV01
TM21CB - mm
11-22
1007July 2015
Eaton.com/bussmannseries
Connectors
Marking label ordering method (typical)
11
TM22CB - mm
Connectors
TM22CB
TM26CB
Part numbers
Descriptions
Part Numbers
Descriptions
TM22CB
TM26CB
TM22CB-DH01
TM26CB-DH01
TM22CB-DH02
TM26CB-DH02
TM22CB-FH01
TM26CB-FH01
TM22CB-FH02
TM26CB-FH02
TM22CB-FH03
TM26CB-FH03
TM22CB-FH04
TM26CB-FH04
TM22CB-FH05
TM26CB-FH05
TM22CB-EH01
TM26CB-EH01
TM22CB-EH02
TM26CB-EH02
TM22CB-DV01
TM26CB-DV01
TM22CB-DV02
TM26CB-DV02
TM22CB-FV01
TM26CB-FV01
TM22CB-FV02
TM26CB-FV02
TM22CB-EV01
TM26CB-EV01
TM26CB - mm
1007July 2015
Eaton.com/bussmannseries
11-23
11
Connectors
Marking label ordering method (typical)
TM27CB - mm
TM27CB
TM28CB
Part numbers
Descriptions
Part numbers
Descriptions
TM27CB
TM28CB
TM27CB-DH01
TM28CB-DH01
TM27CB-DH02
TM28CB-DH02
TM27CB-FH01
TM28CB-FH01
TM27CB-FH02
TM28CB-FH02
TM27CB-FH03
TM28CB-FH03
TM27CB-FH04
TM28CB-FH04
TM27CB-FH05
TM28CB-FH05
TM27CB-EH01
TM28CB-EH01
TM27CB-EH02
TM28CB-EH02
TM27CB-DV01
TM28CB-DV01
TM27CB-DV02
TM28CB-DV02
TM27CB-FV01
TM28CB-FV01
TM27CB-FV02
TM28CB-FV02
TM27CB-EV01
TM28CB-EV01
TM28CB - mm
11-24
1007July 2015
Eaton.com/bussmannseries
Connectors
11
NDNV4
Approval
Approval
Approval
Technical Data
Technical Data
Rated voltage
600V
Rated voltage
600V
Rated voltage
600V
Rated Current
30A
Rated Current
30A
Rated Current
65A
0.3 / 7.62
0.375 / 9.52
22~10 / 0.5~6
18~6 / 1~16
22~10 / 0.5~6
Number of Poles
Number of Poles
Number of Poles
48
38
30
Torque(Nm)
Torque(Nm)
Torque(Nm)
Torque(lb-in)
18
Torque(lb-in)
18
Torque(lb-in)
35
#6-32
WxHxD(mm)
25.4 x 34 x 42.4
Cat. No.
Screw
#6-32
WxHxD(mm)
Cat. No.
NDNV4-WH
White (Standard)
NDN3-WH
Black
NDNV4-BK
Black
Yellow
NDNV4-YE
Blue
Yellow
NDN3-YE
Red
NDN3-RE
Cat. No.
4 circuits
Accessories
2 circuits
JN4
Marking Tape
MTC6
DRL35MML0
DRL35MMHI
NFTA Series
NRA Series
35mm DIN-Rail
C-Rail
C-Rail (low profile)
Dimensions - in (mm)
1.00
(25.40)
#10-32
WxHxD(mm)
Colors
Cat. No.
White (Standard)
NDN63-WH
NDN3-BK
Black
NDN63-BK
NDN3-BL
Yellow
NDN63-YE
Cat. No.
Accessories
Cat. No.
JNDN3
2 circuits
JN3
MT12-1-2
35mm DIN-Rail
C-Rail
C-Rail (low profile)
N/A
Modular Option
Screw
Colors
White (Standard)
Accessories
Mounting
0.25 / 6.35
Colors
Jumper
NDN63
Technical Data
Screw
Block
NDN3
DRL35MML0
DRL35MMHI
NFTA Series
NRA Series
MT12-1-2
35mm DIN-Rail
DRL35MML0
DRL35MMHI
NFTA Series
NRA Series
C-Rail
C-Rail (low profile)
N/A
Dimensions - in (mm)
Connectors
NDN
N/A
Dimensions - in (mm)
Marking
Tape
1.67
1.47
1.23
(42.41) (37.33) (31.24)
1.50
(38.10)
1.47
(37.33)
1.67
(42.41)
1.34
(34.04)
0.94
(23.87)
1.67
(42.41)
1.31
(33.27)
1007July 2015
1.17
(29.71)
Eaton.com/bussmannseries
1.45
(36.83)
11-25
Connectors
11
NDN1
NDN111
Approval
Approval
Technical Data
Technical Data
Rated voltage
600V
Rated voltage
Rated Current
90A
Rated Current
0.635 / 16.13
600V
90A
0.635 / 16.13
18~2 / 0.8~33.6
18~2 / 0.8~33.6
Number of Poles
Number of Poles
18
18
Torque(Nm)
3.6
Torque(Nm)
3.6
32
Torque(lb-in)
Torque(lb-in)
Screw
1/4-28
WxHxD(mm)
15 x 30.3 x 43.5
Colors
Cat. No.
NDN1-WH
White (Standard)
Accessories
Cat. No.
32
Screw
1/4-28
WxHxD(mm)
Colors
Cat. No.
White (Standard)
NDN111-WH
Black
NDN111-BK
Blue
NDN111-BL
Yellow
NDN111-YE
Red
NDN111-RE
Accessories
Cat. No.
2 circuits
JN1
MT12-1-2
35mm DIN-Rail
NDNA Series
DRL35MML
DRL35MMHI
NFTA Series
NRA Series
C-Rail
C-Rail (low profile)
NDN1A-WH
Dimensions - in (mm)
MT12-1-2
35mm DIN-Rail
NDNA Series
DRL35MML
DRL35MMHI
NFTA Series
NRA Series
C-Rail
C-Rail (low profile)
1.32
(33.68)
1.71
(43.48)
Dovetail
Option
0.62
(15.75)
1.87
(47.50)
Dovetail
Option
11-26
0.59
(14.99)
1.43
(36.31)
1.44
(36.57)
1007July 2015
Eaton.com/bussmannseries
Connectors
11
12-pole
N512
NFT2
Approval
Approval
Technical Data
Technical Data
Technical Data
300V
600V
Rated voltage
600V
Rated voltage
Rated current
20A
5A
Rated Current
40A
Rated Current
0.197 / 5.0
22~12 / 0.5~4
Number of Poles
12
60
Torque(Nm)
1.4
Torque(lb-in)
12
#4-48
WxHxD(mm)
Colors
Cat. No.
Black (Standard)
N512-BK
Block
0.28 / 7.13
Number of Poles
Number of Poles
38
28
Torque(Nm)
Torque(Nm)
Torque(lb-in)
18
Torque(lb-in)
18
Screw
#8-32
WxHxD(mm)
Cat. No.
#8-32
WxHxD(mm)
Colors
NFT2-WH
White (Standard)
NFT3-WH
Black
NFT2-BK
Black
NFT3-BK
NFT3-BL
Blue
NFT2-BL
Blue
Red
NFT2-RE
Yellow
NFT3-YE
Red
NFT3-RE
Accessories
2 circuits
Accessories
Cat. No.
2 circuits
JN2
AT512
2.40
(60.96)
22~8 / 0.5~10
White (Standard)
JN512
Dimensions - in (mm)
Screw
Colors
Cat. No.
DRL15MM
NFTA Series
NRA Series
40A
0.39 / 9.91
12 circuits
15mm DIN-Rail
C-Rail
C-Rail (low profile)
600V
22~8 / 0.5~10
Accessories
Marking Tape
Mounting
Approval
Rated voltage
Screw
Jumper
NFT3
Connectors
C-Rail
JN3
MT12-1-2
MT12-1-2
C-Rail
C-Rail (low profile)
NFTA Series
NRA Series
Dimensions - in (mm)
0.60
(15.44)
0.07
(1.78)
C-Rail
C-Rail (low profile)
1.29
(32.94)
0.36
(9.14)
1.18
(29.97)
0.88
(22.35)
1.68
(42.82)
NFTA Series
NRA Series
Dimensions - in (mm)
0.93
(23.80)
1.09
(27.68)
Cat. No.
1.23
(31.34)
1.29
(32.94)
1.23
(31.37)
0.65
(16.51)
1007July 2015
Eaton.com/bussmannseries
11-27
Connectors
11
3-pole
NC3
NSE3
Approval
NSS3
Approval
Technical Data
Approval
Technical Data
Technical Data
Rated voltage
600V
Rated voltage
600V
Rated voltage
Rated Current
175A
Rated Current
115A
Rated Current
1.06 / 26.92
Cu/AL
Number of Poles
11
Torque(Nm)
Torque(lb-in)
WxHxD(mm)
Number of Poles
Number of Poles
11
28
5.1
Torque(Nm)
3.6
Torque(Nm)
1.4
45
Torque(lb-in)
32
Torque(lb-in)
White (Standard)
NC3-WH
Black
NC3-BK
Accessories
Cat. No.
Ring Terminals
Screw
1/4 - 28
WxHxD(mm)
Colors
Cat. No.
NSE3-WH
White (Standard)
NFTA Series
NRA Series
Dimensions - in (mm)
Ring Terminals
Only
12
Screw
#6-32
WxHxD(mm)
Colors
Cat. No.
White (Standard)
NSS3-WH
Black
NSS3-BK
Accessories
Cat. No.
Accessories
Cat. No.
2 circuits
JNSE3
2 circuits
JNSS3
MT12-1-2
MT12-1-2
Panel Mount
C-Rail
C-Rail (low profile)
0.385 / 9.77
5/16 - 24
Colors
30A
Only
14~2/0 /2.5~70
Screw
1.06 / 26.92
600V
Panel Mount
C-Rail
C-Rail (low profile)
NFTA Series
NRA Series
Dimensions - in (mm)
MT12-1-2
NFTA Series
NRA Series
C-Rail
C-Rail (low profile)
Dimensions - in (mm)
1.25
(31.75)
3.12
(79.38)
1.75
(44.45)
0.250 x 0.190
mtg. slots
1.75
(44.45)
1.24
(31.50)
1.75
(44.45)
1.25
(31.75)
1.25
(31.75)
1.32
(33.73)
1.53
(38.86)
0.250 x 0.190"
mtg. slots
3.12
(79.24)
11-28
1007July 2015
Eaton.com/bussmannseries
Connectors
11
Depluggable blocks
15188
15288
Approval
PLU3
Approval
Technical Data
Approval
Technical Data
Technical Data
Rated voltage
600V
Rated voltage
600V
Rated voltage
Rated Current
30A
Rated Current
65A
Rated Current
0.375 / 9.52
16~12 / 1.5~4
Number of Poles
3 or 4
32
UL E62622
CSA File 15364
CSA File 47235 (15188 Series)
Torque(Nm)
WxHxD(mm)
3-Pole
4-Pole
Torque(lb-in)
Screw
0.54 / 13.7
Number of Poles
22
28
1.4
Torque(Nm)
2.3
Torque(Nm)
12
Torque(lb-in)
20
Torque(lb-in)
Screw
#8-32
Cat. No.
White (Standard)
15188-3
White (Standard)
15188-4
Cat. No.
22~8 / 0.5~10
18
Screw
WxHxD(mm)
2 circuits
#8-32
WxHxD(mm)
43.2 x 49.3 x 47.9
N/A
Colors
Cat. No.
Colors
15288
White (Standard)
Accessories
Cat. No.
Cat. No.
White (Standard)
PLU3-WH
Black
PLU3-BK
Yellow
PLU3-YE
Accessories
Cat. No.
2 circuits
15188J-2-J
JN3
MT12-1-2
Marking Tape
35mm DIN-Rail
Mounting
Configurable Option
0.39 / 9.91
Number of Poles
Accessories
40A
Block
Jumper
600V
16~6 / 1.5~16
#6-32
Colors
Connectors
Depluggable blocks
DRL35MMLO
DRL35MMHI
35mm DIN-Rail
DRL35MMLO
DRL35MMHI
15188-_R
15188-_S
15188-_RS
Reverse Wiring
Screw Together
Locking
15288-R
15288-ST
15288-S
Reverse Wiring
Locking
Reverse; Locking
Options offered for both pole lengths
Dimensions - in (mm)
Dimensions - in (mm)
NFTA Series
NRA Series
C-Rail (AL)
C-Rail (low profile)
Dimensions - in (mm)
1.70
(43.2)
2.30
(58.4)
for ST option
0.54
(13.7)
1.25
(31.75)
1.94
(49.27)
1.94
(49.27)
0.59
(14.98)
1.70
(43.2)
1.25
(31.75)
1.94
(49.27)
1.79
(45.64)
1.25
(31.75)
1.85
(46.99)
1.94
(49.27)
1007July 2015
Eaton.com/bussmannseries
11-29
Connectors
11
Depluggable blocks
PSU1
PLU1
Approval
Approval
Technical Data
Technical Data
Rated voltage
600V
Rated voltage
Rated Current
70A
Rated Current
600V
45A
0.625 / 15.88
0.625 / 15.88
18~4 / 1.0~25
Ring Terminals
Number of Poles
1-3
Number of Poles
1-3
19
19
Torque(Nm)
3.6
Torque(Nm)
2.7
32
Torque(lb-in)
Torque(lb-in)
Screw
1/4 - 28
WxHxD(mm)
1-Pole
2-Pole
3-Pole
Colors
Only
24
Screw
#10-32
WxHxD(mm)
1-Pole
2-Pole
3-Pole
Colors
Cat. No.
PLU1-WH
White (1-Pole)
White (2-Pole)
PLU11-WH
White (2-Pole)
PSU11-WH
White (3-Pole)
PLU111-WH
White (3-Pole)
PSU111-WH
White (1-Pole)
Accessories
2 circuits
Cat. No.
PSU1-WH
Accessories
Cat. No.
JN1
MT12-1-2
C-Rail (AL)
C-Rail (low profile)
NFTA Series
NRA Series
Dimensions - in (mm)
1.87
(47.49)
MT12-1-2
NFTA Series
NRA Series
C-Rail (AL)
C-Rail (low profile)
Dimensions - in (mm)
1.85
(46.99)
1.48
(37.59)
1.93
(49.12)
1.48
(37.64)
0.625
(15.88)
2.44
(62.10)
1.25
(31.75)
11-30
0.43
(11.10)
1.30
(33.00)
1007July 2015
Eaton.com/bussmannseries
Connectors
11
KT3
KT4
Approval
Approval
Technical Data
Technical Data
Rated voltage
600V
Rated voltage
Rated Current
40A
Rated Current
30A
Rated Current
0.39 / 9.91
22~8 / 0.5~10
Number of Poles
28
Torque(Nm)
Number of Poles
48
28
Torque(Nm)
Torque(Nm)
18
Torque(lb-in)
18
Torque(lb-in)
Cat. No.
Screw
#6-32
WxHxD(mm)
Colors
Cat. No.
KT4-WH-A
Black
KT3-BK
White*
KT4-WH-B
Red
KT3-RE
Black
KT4-BK
JN3
Accessories
Mounting Foot
Cat. No.
JN3
MT12-1-2
Mounting Foot
Dimensions - in (mm)
0.98
(24.99)
0.25
(6.35)
0.37
(9.40)
1.46
(37.22)
1.22
(31.04)
0.62
(15.88)
KAD
Dimensions - in (mm)
Dimensions - in (mm)
1.25
(31.75)
Cat. No.
PLK3-WH
White (Standard)
MTC6
KAD
1.87
(47.63)
2 circuits
JN4
MT12-1-2
Marking Tape
WxHxD(mm)
Accessories
Cat. No.
4 circuits
18
#8-32
Colors
White*
Cat. No.
22~8 / 0.5~10
Screw
KT3-WH
2 circuits
0.39 / 9.91
Number of Poles
White (Standard)
Accessories
40A
Colors
0.25 / 6.35
600V
22~10 / 0.5~6
#8-32
WxHxD(mm)
Mounting
Technical Data
600V
Screw
Jumper
Approval
Rated voltage
Torque(lb-in)
Block
PLK3
Connectors
0.56
(14.22)
1.26
(32.23)
#8 screw clearance
KAD
end mtg.
adapter
1.79
(45.52)
1.25
(31.75)
2.34
(59.51)
1.34
(34.04)
1.25
(31.75)
1.84
(46.86)
1007July 2015
Eaton.com/bussmannseries
11-31
11
Connectors
Quick connect blocks
3-pole
Quick connect
blocks
NTQ23
BNQ21
Approval
Approval
Technical Data
BQQ41
Approval
Technical Data
Technical Data
Rated voltage
600V
Rated voltage
600V
Rated voltage
Rated Current
40A
Rated Current
40A
Rated Current
0.39 / 9.91
22~8 / 0.3~8.4
Number of Poles
28
Torque(Nm)
Torque(lb-in)
18
Screw
#8-32
WxHxD(mm)
Cat. No.
White (Standard)
30A
0.437 / 11.1
22~8 / 0.3~8.4
Number of Poles
Number of Poles
24
24
Torque(Nm)
Torque(Nm)
NA
Torque(lb-in)
18
Torque(lb-in)
NA
Screw
Colors
0.437 / 11.1
600V
#8-32
WxHxD(mm)
Cat. No.
NA
WxHxD(mm)
Colors
BNQ21-WH
White (Standard)
Terminals Only
Screw
Colors
NTQ23-WH
Cat. No.
BQQ41-WH
White (Standard)
Block
Accessories
Marking Tape
Mounting
Cat. No.
Accessories
Cat. No.
Accessories
Cat. No.
Mounting Foot
BQE
Mounting Foot
BQE
MT12-1-2
C-Rail
C-Rail (low profile)
NFTA Series
NRA Series
Dimensions - in (mm)
Dimensions - in (mm)
#BQE
(end mtg. adaptor)
1.25
(31.75)
11-32
1.25
(31.75)
1007July 2015
#8 mtg.
screw
#BQE
(end mtg. adaptor)
#8 mtg.
screw
0.56
(14.28)
0.56
(14.28)
1.31
(33.32)
1.25
(31.75)
Dimensions - in (mm)
1.47
(37.33)
B
A
1.47
(37.33)
1.41
(35.81)
Eaton.com/bussmannseries
B
A
1.41
(35.81)
Connectors
11
TB100
Specifications
Rating: 30A, 300V*
TB100-08
Connectors
TB100-04SP
Poles
02
03
04
05
06
07
08
09
10
11
12
13
A
1.40
1.78
2.16
2.53
2.90
3.28
3.66
4.03
4.40
4.78
5.16
5.53
B
1.12
1.50
1.88
2.25
2.62
3.00
3.38
3.75
4.12
4.50
4.88
5.25
Dimensions - in
1 = 25.4mm.
Poles
14
15
16
17
18
19
20
21
22
23
24
25
A
5.90
6.28
6.66
7.03
7.40
7.78
8.16
8.53
8.90
9.28
9.66
10.03
B
5.62
6.00
6.38
6.75
7.12
7.50
7.88
8.25
8.62
9.00
9.38
9.75
Poles
26
27
28
29
30
31
32
33
34
35
36
A
10.40
10.78
11.16
11.53
11.90
12.28
12.66
13.03
13.40
13.78
14.16
B
10.12
10.50
10.88
11.25
11.62
12.00
12.38
12.75
13.12
13.50
13.88
TB100- in (mm)
A
0.14
(3.5)
0.14
(3.5)
0.88
(22.3)
0.31 (7.9)
0.17 dia.
(4.3)
0.375
(9.5)
0.30
(7.6)
0.41
(10.4)
0.25 (6.3)
Symbol
TB100
Poles
Screw options
Marking/cover
02 to 36
Hardware options
L1 to L6
Marking Options (See page 11-39)
Marker Strips (See page 11-40)
Special Markings (See page 11-40)
Covers (See page 11-39)
1007July 2015
Eaton.com/bussmannseries
11-33
Connectors
11
Screw options
Bulk:
B
Brass philslot
nickel-plated
F502-J
SP
Steel SEMS
philslot zinc-plated
B001-7021-J
Quick connects assembled: terminals 0.187 x 0.020. Maximum current rating 13 amps. For other orientations, contact Eaton.
Hardware options
QC1
QC8
QC14
QC2
QC3
QC4
QC5
QC6
QC9
QC10
QC11
QC12
QC13
QC15
QC16
QC17
QC18
QC19
Quick connects bulk: minimum order per part number 100 pieces.
QC101-J
Flat none
QC104-J
Flat Flat
QC102-J
QC103-J
QC 45 none QC 90 none
QC105-J
Flat QC 45
QC106-J
QC107-J
QC108-J
QC109-J
Flat QC 90QC 45 QC 45 QC 45 QC 90QC 90 QC 90
Jumpers bulk: minimum order per part number 100 pieces. Contact Eaton for jumper assembly.
J101
Flat slip-on
(Bulk: J101-J)
11-34
OJ2
Slip-on over barrier
(Bulk: OJ2-J)
OJ4
Closed over barrier
(Bulk: OJ4-J)
1007July 2015
Eaton.com/bussmannseries
QC7
QC20
Connectors
11
TB200-10SP
TB200HB-06
TB200 - in (mm)
0.16
(4.0)
A
1.63
2.07
2.51
2.94
3.38
3.82
4.25
4.69
5.13
5.57
B
1.31
1.75
2.18
2.62
3.06
3.50
3.93
4.37
4.81
5.25
Poles
12
13
14
15
16
17
18
19
20
21
Dimensions - in
1 = 25.4mm.
A
6.00
6.44
6.87
7.31
7.75
8.19
8.62
9.06
9.50
9.94
B
5.68
6.12
6.56
7.00
7.43
7.87
8.31
8.75
9.18
9.62
Poles
22
23
24
25
26
27
28
29
30
A
10.37
10.81
11.25
11.68
12.12
12.56
13.00
13.44
13.87
B
10.06
10.50
10.93
11.37
11.81
12.25
12.68
13.12
13.56
1.12
(28.4)
0.17 dia.
(4.3)
0.437
(11.1)
0.353
(8.9)
0.56
(14.2)
0.31 (7.8)
TB200HB
A
0.16
(4.0)
0.90
1.37
(22.8) (34.8)
0.44 (11.2)
0.437
(11.1)
TB
200 - Standard
200HB - High barrier
0.353
(8.9)
0.75
(19.0)
0.33 (8.4)
0.16
(4.0)
0.17 dia.
(4.3)
Symbol
0.16
(4.0)
0.44 (11.2)
Poles
02
03
04
05
06
07
08
09
10
11
Connectors
Poles
Screw options
Marking/cover
Hardware options
02 to 30
1007July 2015
Eaton.com/bussmannseries
11-35
Connectors
11
Screw options
B
Brass philslot
nickel-plated
Bulk: B001-7016-J
BS
Brass SEMS
philslot nickel-plated
B001-7019-J
SP
Steel SEMS
philslot zinc-plated
B001-7007-J
P
Steel SEMS
(P-style)
B001-7000-J
ST
Stainless steel
philslot
F507-J
SS
Stainless steel
SEMS philslot
B001-7085-J
Hardware options
Quick connects assembled: Terminals 0.25 x 0.031. Maximum current rating 20 amps. For other orientations, contact Eaton.
QC1
QC2
QC3
QC4
QC5
QC6
QC8
QC9
QC11
QC10
QC12
QC13
QC14
QC15
QC16
QC17
QC18
QC19
Quick connects bulk: minimum order per part no. 100 pieces.
QC201-J
QC 45 blank
QC204-J
Flat Flat
QC202-J
Flat blank
QC205-J
Flat QC 45
QC203-J
QC 90 blank
QC206-J
Flat QC 90
QC207-J
QC 45 QC 45
QC208-J
QC209-J
QC 45 QC 90 QC 90 QC 90
Jumpers bulk: minimum. order per part no. 100 pieces. Contact Eaton for jumper assembly.
J201
Flat slip-on
(not available on TB200HB)
(Bulk: J201-J)
11-36
OJ3
Slip-on over
barrier for TB200HB
(Bulk: OJ3-J)
OJ5
Closed over
barrier for TB200HB
(Bulk: OJ5-J)
1007July 2015
OJ7
Closed over
barrier for TB200
(Bulk: OJ7-J)
Eaton.com/bussmannseries
QC7
QC20
Connectors
11
TB300-08
TB345-06SP
Poles
02
03
04
05
06
07
08
09
A
2.13
2.69
3.25
3.81
4.37
4.94
5.50
6.06
B
1.69
2.25
2.81
3.37
3.94
4.50
5.06
5.62
Dimensions - in
1 = 25.4mm.
Poles
10
11
12
13
14
15
16
17
A
6.62
7.18
7.75
8.31
8.87
9.43
9.99
10.56
B
6.19
6.75
7.31
7.87
8.44
9.00
9.56
10.12
Poles
18
19
20
21
22
23
24
A
11.12
11.68
12.24
12.80
13.37
13.93
14.49
B
10.68
11.25
11.81
12.37
12.93
13.50
14.06
Symbol
TB
Poles
0.90
1.33
(22.8) (33.8)
0.50 (12.7)
0.56
(14.2)
0.21dia.
(5.3)
0.56
(14.2)
0.412
(10.4)
0.81
(20.5)
0.33 (8.4)
Screw options
Marking/cover
Hardware options
Custom options
J301 = Flat slip-on jumper
OJ6 = Over barrier jumper
OJ11 = Over barrier jumper
1007July 2015
Eaton.com/bussmannseries
11-37
Connectors
11
Screw options
TB300 Blk:
TB345 Blk:
B
Brass philslot
nickel-plated
B001-7018-J
B500-023-028-J
BS
Brass SEMS
philslot nickel-plated
B001-7015-J
SP
Steel SEMS
philslot zinc-plated
B001-7017-J
ST
Stainless steel
philslot
B001-7063-J
B001-7064-J
Hardware options
Quick connects assembled: TB300 only. Terminals 0.25 x 0.031. Maximum current rating 20 amps. For other orientations, contact Eaton.
QC1
QC2
QC8
QC9
QC14
QC15
QC3
QC4
QC5
QC6
QC10
QC11
QC12
QC13
QC16
QC17
QC18
QC19
QC7
QC20
Quick connects bulk: (*TB300 only) minimum order per part number. 100 pieces.
QC201-J
Flat blank
QC202-J
QC 45 blank
QC203-J
QC 90 blank
QC204-J
Flat Flat
QC205-J
Flat QC 45
QC206-J
Flat QC 90
QC207-J
QC208-J
QC 45 QC 45 QC 45 QC 90
QC209-J
QC 90 QC 90
Jumpers bulk: minimum order per part number 100 pieces. Contact Eaton for jumper assembly.
J301
Flat slip-on(TB300 only)
(Bulk: J301-J)
11-38
OJ6
Closed over barrier
(Bulk: OJ6-J)
OJ11
Slip-on over barrier
(Bulk: OJ11-J)
1007July 2015
Eaton.com/bussmannseries
Connectors
11
3 2 1
L1
L2
L3
1 2 3
3 2 1
L4
L5
L6
134
RED
BLK
BLU
20A
INPUT
OUT
PUT
3AC
134
MAS
TER
GND
300V
MAX
Connectors
MB
Special marking
1 2 3
1
2
3
1
2
3
Standard marking
Covers
Symbol
X
Cover strip
Poles
02 to 36 (TB100)
02 to 30 (TB200/TB200HB)
02 to 24 (TB300/TB345)
HB = High barrier
TB100/white
TB100/clear
TB200/TB200HB - white
TB200/TB200HB - clear
TB300 & TB345 - white
TB300 & TB345 - clear
Part number
DD1-J
TB100
DD2-J
TB200
DD2HB-J TB200HB
DD3-J
TB300
1007July 2015
Eaton.com/bussmannseries
11-39
Connectors
11
Top and bottom marking strips for double row terminal blocks
Series
X
Poles
133
103
233
203
333
303
02 to 36 (TB100)
02 to 30 (TB200/TB200HB)
02 to 24 (TB300/TB345)
HB = High Barrier
Symbol
X
Dimensions (in)
Dim.
A
B
TB100
1.13
1.38
TB200
1.37
1.62
11-40
TB200HB TB300
1.62
1.58
1.81
1.81
Poles
Orientation
02 to 36 (TB100)
02 to 30 (TB200/TB200HB)
02 to 24 (TB300/TB345)
BF = Bottom forward
BR = Bottom reverse
TF = Top forward
TR = Top reverse
1007July 2015
Eaton.com/bussmannseries
TB345
1.58
1.81
TB400
N/A
N/A
Connectors
11
TB400
Specifications
Ratings:
Volts: 600V
Amps: 75A
TB400-05
TB400 - in (mm)
A
2.51
3.20
3.89
4.58
B
2.06
2.75
3.44
4.13
Dimensions - in
1 = 25.4mm.
Poles
06
07
08
09
A
5.26
5.95
6.64
7.33
B
4.81
5.50
6.19
6.88
Poles
10
11
12
A
8.01
8.70
9.39
B
7.56
8.25
8.94
A
B
0.22
(5.6)
0.15 dia.
(3.8)
0.625
(15.9)
1.12
(28.4)
0.687
(17.4)
Screw options
0.562
(14.3)
1.81
(46.0)
0.76
(19.3)
0.46 (11.7)
Brass philslot
nickel-plated
Bulk: B500-023-028-J
Stainless steel
philslot
B001-7064-J
1.34
(34.0)
Hardware options
Symbol
TB400
Poles
Screw options
Marking
Custom options
02 to 12
Not available
1007July 2015
Eaton.com/bussmannseries
11-41
Connectors
11
KU
Specifications
Ratings:
Volts: 600V
Amps: 60A*
KU - in (mm)
0.62
(15.9)
#10 screw
clearance
KU
A
2.50
3.12
3.75
5.00
6.25
7.50
8.75
Dimensions - in
Poles
02
03
04
06
08
10
12
1 = 25.4mm.
B
1.62
2.25
2.87
4.12
5.37
6.62
7.87
KUX only
A
2.00
2.62
3.25
4.50
5.75
7.00
8.25
1.25
(31.8)
0.43
(11.1)
0.50
(12.7)
Accessories***
MTMU##
molded marking tape
matte finish
NUM##
molded marking
tape
Symbol
Poles
KU
= Standard block
02 to 12
KUX
= Short block
KURL = Standard w/removable link
KUXRL = Short block w/removable link
Poles
02 to 12
JU12
jumper
12 circuits
NUE
end piece for NUC
NUC##
cover
Screw options
Covers
Marking strip
MT = Matte finish
NU = Numbered 1 to 12, horizontal
NUV = Numbered 1 to 12, vertical
PT = Marker strip for cover
Screw options
Covers
Marking strip
Symbol
11-42
1.50
(38.1)
2.00
(50.8)
1007July 2015
Requires
Eaton.com/bussmannseries
WC cover option
Connectors
11
Dimensions - mm (in)
Catalog
numbers
C7021-01-X
C7021-02-X
C7021-03-X
C7021-04-X
C7021-05-X
C7021-06-X
C7021-01N-X
C7021-02N-X
C7021-03N-X
C7021-04N-X
C7021-05N-X
C7021-06N-X
C7021
14.2
( .56)
17.5
34.9
52.3
69.8
87.2
(0.69)
(1.37)
(2.06)
(2.75)
(3.44)
(0.69)
(0.69)
(2.06)
(2.75)
(3.44)
36.1
53.5
71.0
88.4
105.9
54.4
70.9
89.3
106.8
124.2
(1.42)
(2.11)
(2.80)
(3.48)
(4.17)
5.4
(0.21)
(2.14)
(2.83)
(3.52)
(4.20)
(4.89)
67.3
84.8
102.2
119.7
134.1
12.5
(0.49)
1/4-20 UNC-2A
Thread TYP
(2.65)
(3.34)
(4.02)
(4.71)
(5.40)
31.8
49.2
66.7
84.2
101.7
31.8
49.2
66.7
84.2
101.7
9.6
28.0 (0.38)
(1.10)
15.8
(0.62)
15.8
(0.62)
7.9
(0.31)
(1.25)
(1.94)
(2.63)
(3.31)
(4.00)
(1.25)
(1.94)
(2.63)
(3.31)
(4.00)
55.7
(2.19)
9.0 TYP
(0.35)
12.2 TYP
(0.48)
B
17.5 TYP
(0.69)
15.0 TYP
(0.59)
Typical applications
Applications requiring up to 175A utilizing a 2-hole
compression lug on 58" centers
Input/output block for telecommunications power panels
Use to eliminate busbars
17.5
34.9
52.3
69.8
87.2
*175 achieved using both studs in parallel, 115A using a single stud per line.
Panel cutouts
24.0
(0.94)
12.7
(0.50)
33.0
(1.30)
14.5 TYP
(0.57)
1.6
(R.06)
30.0
(1.18)
Symbol
C7021
Poles
Mount ends
Studs
01 = 1-Pole (2 studs)
02 = 2-Pole (4 studs)
03 = 3-Pole (6 studs)
04 = 4-Pole (8 studs)
05 = 5-Pole (10 studs)
06 = 6-Pole (12 studs)
Blank = Standard
M6 = M6 studs
Hardware
Blank = No hardware
0 = Bulk pack, one set
1 = Bulk pack, two sets
2 = Assembled, bottom
3 = Assembled, top
4 = Assembled, both sets
1007July 2015
Eaton.com/bussmannseries
11-43
Connectors
Specifications
Description: Power
feed through terminal
block with two rows
1
4-20 studs capable of
accommodating the
industry standard
two-hole compression
lugs on both studs in
parallel.
Ratings:
Volts: 300V
Amps: 115/175A* per pole
Center spacing: 0.690" (17.5mm).
Wire range: AWG #3/0-8.
Poles: 1- to 6-poles.
Bolt Hole Spacing: 0.625" or 58 (15.88mm).
Stud: Standard 14-20 stud (tin-plated brass) or optional M6
stud.
Mounting: #6 thread cutting screws (not included) or
optional mounting ears.
Torque rating: 36 lb-in.
Operating temperature: 130C.
Agency information: UL/CSA; CE Certified.
Connectors
11
C7024
Specifications
Description: A
power feed through
terminal block with
two rows of 14-28
studs capable of
accommodating the industry standard two-hole compression
lugs on 34" centers.
Ratings:
Volts: 600V
Amps: 115A per pole
Center spacing: 0.75" (19.1mm).
Wire range: #2-8 AWG.
Poles: 1 to 12.
Bolt hole spacing: 0.75" (19.1mm).
Stud: Standard 14-28 stud (tin-plated bronze).
Torque rating: 36 lb-in.
Operating temperature: 130C.
Agency information: UL/C-UL, CSA; CE Certified.
Flammability rating: UL 94V0.
Catalog
number
C7024-01
C7024-02
C7024-03
C7024-04
C7024-05
C7024-06
C7024-07
C7024-08
C7024-09
C7024-10
C7024-11
C7024-12
Catalog numbers
Poles
01
02
03
04
05
06
07
08
09
10
11
12
Typical applications
Applications requiring up to 115A utilizing a 2-hole
compression lug on 34" centers
Ideal as an input/output block for telecommunications power
panels
Use to eliminate busbars
A Dimension- mm (in)
0.4 (0.02)
B Dimension- mm (in)
21.6 (0.85)
40.6 (1.60)
19.05 0.08 (0.750 0.003)
59.7 (2.35)
38.10 (1.500)
78.7 (3.10)
57.15 0.26 (2.250 0.010)
97.8 (3.85)
76.2 (3.00)
116.8 (4.60)
95.25 0.26 (3.750 0.010)
135.9 (5.35)
114.30 0.38 (5.250 0/015)
154.9 (6.10)
133.35 0.38 (5.25 0.015)
174.0 (6.85)
152.40 0.38 (6.00 0.015)
193.0 (7.60)
171.45 0.38 (6.750 0.015)
212.1 (8.35)
190.50 0.38 (7.500 0.015)
231.1 (9.10)
209.55 0.38 (8.250 0.015)
Dimensions - mm (in)
17.780 TYP
[0.700]
MIN. AT STUD PAD
13.2TYP
[0.52]
0.5 TYP
[0.02 ]
B
A
28.0
[1.10]
17.8TYP
[0.70]
2.70TYP
[ 0.106 ]
3.16TYP
[0.124]
19.06 0.08
[ 0.750 0.003]
14.4
[0.57]
40.6
[1.60]
Symbol
C7024
11-44
Poles
01-12
1007July 2015
16.53TYP
[0.651]
Eaton.com/bussmannseries
Disconnect switches
12
Contents
Description
Page
1007July 2015
Eaton.com/bussmannseries
12-1
Disconnect
switches
Disconnect switches
12
30
CC
2
600Vac 200kA
Single/Dual
30
CC
3
600Vac 200kA
3
4
7.5
8-6AWG
30
UL Midget
240Vac
10kA
Sol/Str
1
32*
10x38 IEC
400Vac 120kA
75C
30
UL Midget
240Vac 10kA
Single
Cu or
2
32*
10x38 IEC
400Vac 120kA
4AWG
higher
30
UL Midget
240Vac 10kA
Sol/Str
3
32*
10x38 IEC
400Vac 120kA
30
CC
1
80Vdc
20kA
Spade
30
CC
Terminal
1
80Vdc
10kA
32*
10x38 IEC
*32A Class aM, 25A Class gG.
SCCR May be lower, refer to installed fuse data sheets.
Spade terminal with a 4.3mm gap for a #8-32 stud, 30A max, insulated flange, wire size 12-10AWG.
- 18-10AWG; 20 Lb-In
- 8-4AWG; 35 Lb-In
Specifications
Part
number
CCP-1-30CC
CCP-2-30CC
CCP-3-30CC
Agency information
UL 98 Listed, cULus 22.2, No. 4-04
UL 98 Listed, cULus 22.2, No. 4-04
UL 98 Listed, cULus 22.2, No. 4-04
UL 508 Listed, cULus 22.2, No. 14-05
IEC 60947-3, AC23A
UL 508 Listed, cULus 22.2, No. 14-05
IEC 60947-3, AC23A
UL 508 Listed, cULus 22.2, No. 14-05
IEC 60947-3, AC23A
UL 98 Listed, CSA 22.2, No. 4-04
UL 508 Listed, cULus 22.2, No. 14-05
IEC 60947-3, DC23A
CCP-1-30M
CCP-2-30M
CCP-3-30M
CCP-1-DCC
CCP-1-DCM
Features
Agency information
Accessories
Auxiliary contacts
PLC wired remote fuse indication
CE compliant
RoHS compliant
For Class CC fuse versions
- UL 98 Listed, File E302370, Guide WHTY
- cULus to CSA Standard 22.2 No. 4-04, File 302370,
Guide WHTY7
For UL midget and 10X38 IEC fuse versions
- UL 508 Listed, File E320230, Guide NRNT
- cULus Certified 22.2 No. 14-05
- IEC 60947-3 AC23A
- IEC 60947-3 DC23A
Switch handle
Padlock provision
Terminals
Fuse holder
knob
Circuit marking
area
Spade terminal
Torque
Open fuse
indication light
18-10AWG 20 Lb-In
8-4AWG 35 Lb-In
Box lug
terminal
Flammability rating
Lockout/tagout provisions
UL 94V0
Mounting
** Open fuse indication requires an open fuse to be in the CCP and the switch in the
ON position.
Fuse
class
CC
CC
CC
M
M
M
M
M
gG/gL
aM
Type/description
LP-CC time-delay, current limiting
FNQ-R time-delay
KTK-R fast-acting
FNM time-delay
FNQ time-delay
KTK fast-acting
BAF fast-acting
KLM fast-acting
C10G
C10M
1007July 2015
Eaton.com/bussmannseries
Volts
600Vac/300Vdc
600Vac/300Vdc
600Vac
250Vac
500Vac
600Vac
250Vac
600Vac/dc
500V (400V@32A)
500V (400V@20@25A)
Data
Sheet #
1023
1014
1015
2028
1012
1011
2011
2020
720115
720115
Disconnect switches
12
52.5
(2.1)
49.2
(1.9)
79.8
(3.1)
17.5
(0.7)
35
(1.4)
Disconnect
switches
92.7
(3.7)
Auxiliary contacts
CCP-_-30_ accessories
Max
per
CCP
Signal
output
1 per CCP
(1-, 2- or 3-pole)
5A/
240Vac
1 per CCP
(1-, 2- or 3-pole)
24Vdc/
10mA
100Vac
Description
Minimum
circuit
voltage
PLC indicator
(Includes leads with spade terminals)
Agency
information
UL 98 Recognized,
cURus 22.2 No. 4-04,
IEC 60947-5-1 AC15
UL 98 Recognized,
cURus 22.2 No. 4-04
Part
number
CCP-AUX*
CCP-PLC-IND*
1007July 2015
Eaton.com/bussmannseries
12-3
Disconnect switches
12
Catalog symbol:
CCPLP-(poles)-(amps)-(terminal)
Description:
The revolutionary Bussmann series Low Profile Compact Circuit
Protector (CCPLP) fused disconnect switch is available in 1-, 2- and
3-pole versions for UL Class CC (1/10-30A), Class G (20A),
13/32x1-1/2 midget UL (1/10-30A) and IEC 10x38 aM/gG
(0.16-32A) fuses.
CE compliant
RoHS compliant
UL Class G,
Effective
Class CCJune
and G2015
versions are easily selectively coordinated with
Low to
Profi
Compact
Circuit
Protector
cULus
CSAle
Standard
22.2 No.
4-04, File
302370, (CCPLP)
Guide
CC, midget
andWHTY7
IEC 10x38mm fused disconnect switches
Catalog
designs andsymbol:
provides a high SCCR alternative to low profile circuit
Agency information
Specifications:
Description:
Ratings
The
revolutionary Bussmann series Low Profile Compact Circuit
Protector
fused disconnect switch is available in 1-, 2- and
Frequency(CCPLP)
- 50/60Hz
3-pole versions for UL Class CC (1/10-30A), Class G (20A),
Impulse
13/32x1-1/2
midget UL (1/10-30A) and IEC 10x38 aM/gG
- 8kV
voltage
(0.16-32A)
fuses.
VoltsCCPLP -has
600Vac
(Class CC
up to 30A,
Class
The
the smallest
footprint
of any
UL G
9820A)
Listed fused
disconnect switch
along
withIEC
up Class
to a 200kA
SCCR to help improve
- 550Vac
(10x38
aM 0.16-16A)
equipment SCCR.
- 500Vac (10x38 IEC Class gG 0.5-25A)
Class CC and G versions are easily selectively coordinated with
- 400Vac (10x38 IEC Class aM 20-32A, gG 32A)
upstream CUBEFuses using published fuse ampacity ratio tables.
- 240Vac (13/32 x 1-1/2 midget UL 30A)
Unique panel mounting permits easy integration into many panel
Amps and- provides
Up to 30A
(UL) SCCR alternative to low profile circuit
designs
a high
breakers on -the
Up market.
to 32A (IEC)
- Up to 30A (UL)
- Up to 32A (IEC)
SCCR
Pressure
terminal
- #10-32 phil-slot screw single
For
Class plate
CC fuse
versions
22-6AWG solid or stranded
UL 98 Listed, Guide WHTY
cULus
to CSA
Standard 22.2 No. 4-04, File 302370,
Terminal
screw
torque
Guide WHTY7
20 Lb-In (2.2 Nm)
IEC 60947-3 AC-23A
Mounting
Ambient
Pressurestorage
plate terminal
- #10-32 phil-slot
screw
and operating
temperature
single
22-6AWG solid or stranded
-20C to 90C, 85% relative humidity non-condensing
Brady pin-out
device,
P/N
90844
Mounting
screw
torque
4-5
Lb-In (0.4-0.5 Nm)
Mounting
Lockout/tagout provisions
Front panel mounting with customer supplied M3 screws
Circuitfuse
labeling
provisions
Open
indication*
Accepts
up fuse
to two
universal
marker by
labels
(P/N TM26CB)
Local
open
indication
provided
a orange
neon lamp on
each pole, minimum voltage 90Vac
- 100kA (Class G)
Carton quantity
Open
fuse(1-pole:
indication12
requires
energized,
closed3-pole:
circuit with
an open
12
poles
units,an2-pole:
6 units,
4 units)
fuse in the CCPLP and the switch in the ON position.
AC-23A
Poles
12-4
terminal
IEC 60947-3
- 100kA (Class G)
Frequency - 50/60Hz
- 10kA (13/32x1-1/2 midget UL)
Impulse
- 8kV
Poles
voltage
1-, 2- and 3-pole factory configured
Volts
- 600Vac (Class CC up to 30A, Class G 20A)
2- and 3-pole versions feature ganged switches and
- 550Vac (10x38 IEC Class aM 0.16-16A)
phase barriers.
- 500Vac (10x38 IEC Class gG 0.5-25A)
Amps
Open
fuse
indication*
IEC
60947-3
AC-23A
SCCR
- 200kA (Class CC)
Specifi
cations:
Ratings
Eaton.com/bussmannseries
Minimumn
enclosure
size
Ambient
storage
and operating
temperature
6x6x4
per UL
98relative
Listing humidity non-condensing
-20C
to 90C,
85%
Flammability rating
UL 94 V2
Lockout/tagout provisions
Brady pin-out device,
1007July 2015 Eaton.com/bussmannseries
P/N 90844
Disconnect switches
12
Catalog numbers:
Class G fuses
Catalog number
Screw terminal
Poles
Volts AC
Amps
SCCR (kA)
CCPLP-1-20G-S
CCPLP-1-20G-P
600
20
100
CCPLP-2-20G-S
CCPLP-2-20G-P
600
20
100
CCPLP-3-20G-S
CCPLP-3-20G-P
600
20
100
Class CC fuses
Catalog number
Poles
Volts
AC
Max
amps
SCCR
(kA)
120
240
480
600
CCPLP-1-30CC-P
600
30
200
0.5
CCPLP-2-30CC-P
600
30
200
600
30
200
7.5
Screw terminal
CCPLP-1-30CC-S
CCPLP-2-30CC-S
CCPLP-3-30CC-S
CCPLP-3-30CC-P
Low Profile Compact Circuit Protector (CCPLP)
3
Technical Data 10372
UL Class
G, CC, midget
and Guide
IEC 10x38mm
fused
disconnect
switches
Agency
information:
UL 98 Listed,
WHTY, cULus
to CSA
Standard 22.2
No. 4-04, File 302370, Guide WHTY7,
CE,June
RoHS
compliant.
Effective
2015
Disconnect
switches
Features:
Screw
terminal
Full voltage
rated up to 600Vac
120kA (IEC)
CCPLP-2-30M-S
CCPLP-2-30M-P
Mounting and panel layout dimensions match common low-
Fuse
Class
CC
CC
CC
Type/description
Volts
Poles
Volts AC
LP-CC time-delay, current-limiting
1FNQ-R time-delay
KTK-R fast-acting
240
Data
sheet No.
600Vac
Max amps
1023
SCCR (kA)
600Vac
30
10
600Vac
1015
240
3FNM time-delay
240
FNQ time-delay
500Vac
1012
KTK fast-acting
600Vac
1011
Extremely
at 19mm
per pole
10x38
IECcompact
Classdesign
gG and
aMwide
fuses
2011
30
1014
600Vac
30
250Vac
10
1024
10
2028
Agency
information: CE, RoHS compliant, cULus Listed to CSA 22.2 No. 14-05, UL 508 Listed, File E230230, Guide NRNT.
Disconnect rated to provide means for load isolation
BAF fast-acting
250Vac
KLM fast-acting
600Vac
gG
C10G (0.5-25A)
500Vac
gG
C10G (32A)
400Vac
Screw
terminal
branch circuit
protection
CCPLP-1-30M-S
aM
aM
CCPLP-1-30M-P
Poles
Fuse class
C10M (0.16-16A)
C10M (20-25A)
CCPLP-2-30M-P
550Vac
gG
500
400Vac
aM
2020
720115
Volts
AC
720115
(amp 720115
range)
SCCR (kA)
(0-25)720115
/ 400 (32)
120
120
gG
120
aM
120
gG
Low ProfiCCPLP-3-30M-S
le Compact Circuit Protector (CCPLP)
3
Circuit labeling provisions for easy CCPLP-3-30M-P
identification using TM26CB
aM
UL Class G,
CC,
midget
and
IEC
10x38mm
fused
disconnect
switches
labels (order separately)
Data 120
10372
Agency information: CE, RoHS compliant, IEC 60947-3 AC-23A, cULus Listed to CSA 22.2 No. 14-05, UL 508 Listed, File E230230, Guide NRNT.
Switch handle (ganged on 2- and 3-pole versions)
Features:
Suitable Fuse
for global
installations accepting Open
UL Class
G and light
CC,
fuse indicating
access door
midget or IEC gG and aM fuses
Fuse
Class
Type/description
CC
CC
Mounting and panel layout dimensions match common lowprofile circuit breakers to provide an easy, alternative fused circuit
protection solution.
Mounting holes
M3 screws
Circuit
Class CCmarking
version is suitable
area protection
branch circuit
Lockout/
tagout
provision*
10/32 phil-slot
screw or
pressure plate
terminal
safety
Volts
Data
sheet No.
600Vac
1023
FNQ-R time-delay
600Vac
1014
CC
KTK-R fast-acting
600Vac
1015
SC time-delay (20A)
600Vac
1024
2028
FNM time-delay
250Vac
FNQ time-delay
500Vac
1012
KTK fast-acting
600Vac
1011
BAF fast-acting
250Vac
2011
KLM fast-acting
600Vac
2020
gG
C10G (0.5-25A)
500Vac
720115
gG
C10G (32A)
400Vac
720115
aM
C10M (0.16-16A)
550Vac
720115
aM
C10M (20-25A)
400Vac
720115
Local open
fuse indication on each pole standard
barrier
1007July 2015
Eaton.com/bussmannseries
12-5
Disconnect switches
12
No.
of
poles
30
CF
30
CF
30
CF
60
CF
60
CF
60
CF
Amp
rating
Specifications
100
CF
100
CF
100
CF
*
**
Volts
600Vac
125Vdc
600Vac
125Vdc
600Vac
125Vdc
600Vac
125Vdc
600Vac
125Vdc
600Vac
125Vdc
600Vac
SCCR
200kA
100kA
200kA
100kA
200kA
100kA
200kA
100kA
200kA
100kA
200kA
100kA
200kA
125Vdc 100kA
600Vac 200kA
125Vdc 100kA
600Vac 200kA
15
10
7.5
7.5
20
10
10
Spade
Terminal
Single
8-10AWG
Sol/Str
8-1AWG Str
Dual
6AWG Str
Spade
Terminal
Agency information
Single/Dual
18-6AWG
Sol/Str
Single
4AWG
Sol/Str
Part
number
20
50
50
CCP-3-100CF UL 98 Listed, cULus 22.2, No. 4-04
125Vdc 100kA
With time-delay Low-Peak CUBEFuse.
30-60A: 18-10AWG 20 Lb-In, 8-6AWG 35 Lb-In, 4AWG 35 Lb-In.
70-100A: 18-10AWG Single 25 Lb-In, 8-1AWG Single 35 Lb-In, 6AWG Dual 45 Lb-In.
Spade terminal with a 4.3mm gap for a #8-32 stud, 30A max, insulated flange, wire size 12-10AWG.
Up to 40A max, >40A is 24Vdc.
Up to 80A max, >80A is 24Vdc.
Agency information
CE compliant
RoHS compliant
UL 98 Listed, File E302370, Guide WHTY
cULus to CSA Standard 22.2 No. 4-04,
File 302370, Guide WHTY7
Terminals
Single/dual conductor box lug or spade terminal suitable
for line, load or accessory connection
Torque: 0-60A: - 18-10AWG 20 Lb-In
- 8-6AWG 35 Lb-In
- 4AWG 35 Lb-In
70-100A: - 18-10AWG single 25 Lb-In
- 8-1AWG single 40 Lb-In
- 6AWG dual 45 Lb-In
Fuses
Uses finger-safe Class CF CUBEFuse with Class J
performance
Low-Peak dual-element, time-delay*
- Non-indicating 1-100A
- Indicating 6-100A
Fast-acting, non-indicating 1-100A**
* See Data Sheet # 9000
** See Data sheet # 2147
Mounting
35mm DIN-Rail
Local open fuse indication minimum voltage
90V
Open fuse indication requires an open fuse to be in the CCP and the switch in the
ON position.
Features
Ampacity rejecting disconnects will not accept
CUBEFuse amp ratings greater than switch rating
IP20 Finger-safe construction with 10AWG (6mm2) wire
or larger
Built-in switch interlock capability prohibits removing the
fuse under load
Accessories
Auxiliary contacts
PLC wired remote fuse indication
CUBEFuse pullers (P/Ns: CFP-30, CFP-60, CFP-100)
Lockout provision
Circuit
marking area
Switch handle
Open fuse
indication light
*** For fuse performance under or above 25C, consult fuse performance derating charts
in the Eaton publication titled Selecting Protective Devices (SPD) reorder #3002.
Flammability rating
UL 94V0
Lockout/tagout provisions
4mm shank lock or Brady pin-out device, part number
90850
Spade terminal
Fuse holder
1007July 2015
Eaton.com/bussmannseries
Box lug
terminal
Disconnect switches
12
50.4
(2.0)
9.1
(0.4)
60A CUBEFuse
89.1 (3.5)
30A CUBEFuse
83.3 (3.3)
49.2
(1.9)
60.3 (2.4)
75.1
(3.0)
25.1
(1.0)
75.7
(3.0)
113.9
(4.5)
7.6
(0.3)
25.15
(1.0)
79.5
(3.0)
Disconnect
switches
56.6
(2.2)
67.7
(2.7)
91.2
(3.6)
100.0
(3.9)
100 Amp
50.5
(2.0)
147.1
(5.8)
Auxiliary contacts
CCP-_-_CF accessories
Max
per
CCP
Signal
output
1 per CCP
(1-, 2-, 3-pole)
5A/
240Vac
1 per CCP
(1-, 2-, 3-pole)
1 per CCP
(1-, 2-, 3-pole)
1 per CCP
(1-, 2-, 3-pole)
5A/
240Vac
24Vdc/
10mA
24Vdc/
10mA
Description
PLC indicator
(Includes leads with spade terminals)
Minimum
circuit
voltage
100Vac
100Vac
Agency
information
UL 98 Recognized,
cURus 22.2 No. 4-04,
IEC 60947-5-1 AC15
UL 98 Recognized,
CSA C22.2 No. 4
UL 98 Recognized,
cURus 22.2 No. 4-04
UL 98 Recognized,
CSA C22.2 No. 4
Part
number
CCP-AUX*
CCP-AUX-100*
CCP-PLC-IND*
CCP-PLC-100*
1007July 2015
Eaton.com/bussmannseries
12-7
12
Disconnect switches
Compact Circuit Protector Base (CCPB) with CUBEFuse
Specifications:
RoHS compliant
Agency information:
Environmental data
12-8
1007July 2015
Eaton.com/bussmannseries
Disconnect switches
12
Technical Ratings
CCPB part
numbers
CCPB-1-15CF
CCPB-2-15CF
Poles
1
2
3
CCPB-1-20CF
CCPB-2-20CF
1
2
CCPB-3-20CF
CCPB-1-30CF
CCPB-2-30CF
1
2
CCPB-3-30CF
CCPB-1-40CF
CCPB-2-40CF
1
2
CCPB-3-40CF
CCPB-1-50CF
CCPB-2-50CF
1
2
CCPB-3-50CF
CCPB-1-60CF
CCPB-2-60CF
1
2
CCPB-3-60CF
CCPB-1-70CF
CCPB-2-70CF
1
2
CCPB-3-70CF
CCPB-1-90CF
CCPB-2-90CF
3
1
2
CCPB-3-90CF
CCPB-1-100CF
CCPB-2-100CF
3
1
2
CCPB-3-100CF
600Vac
125Vdc
Time-delay
non-indicating
Time-delay
indicating*
Fast-acting
non-indicating
Max. fuse**
ampacity
TCF1RN, TCF3RN,
FCF1RN, FCF3RN,
TCF6, TCF10,
TCF6RN, TCF10RN,
FCF6RN, FCF10RN,
TCF15
TCF15RN
FCF15RN
600Vac
125Vdc
TCF17-1/2RN,
TCF20RN
600Vac
125Vdc
SCCR
15A
200kA
TCF17-1/2,
TCF20
FCF20RN
20A
200kA
TCF25RN,
TCF30RN
TCF25, TCF30
FCF25RN,
FCF30RN
30A
200kA
600Vac
125Vdc
TCF35RN,
TCF40RN
TCF35, TCF40
FCF35RN,
FCF40RN
40A
200kA
600Vac
24Vdc
TCF45RN,
TCF50RN
TCF45, TCF50
FCF45RN,
FCF50RN
50A
200kA
600Vac
24Vdc
TCF60RN
TCF60
FCF60RN
60A
200kA
600Vac
125Vdc
TCF70RN
TCF70
FCF70RN
70A
200kA
600Vac
125Vdc
TCF90RN
TCF90
FCF80RN,
FCF90RN
90A
200kA
600Vac
24Vdc
TCF100RN
TCF100
FCF100RN
100A
200kA
*1A and 3A indicating CUBEFuse not available. Correct fit with CCPB disconnect requires indicating CUBEFuse with date code R38 or later.
**Any fuse with an amp rating less than or equal to the max fuse rating may be used.Example: TCF15 may be used with CCPB-1-20CF.
***Do not use UPS/Critical Application fast-acting CF with motors.
Up to 80 amps. >80A rated 24Vdc.
1007July 2015
Hp ratings***
0.5Hp@120V
1.5Hp@240V
3Hp@240V
5Hp@480V
7.5Hp@600V
0.75Hp@120V
2Hp@240V
3Hp@240V
7.5Hp@480V
10Hp@600V
1.5Hp@120V
3Hp@240V
5Hp@240V
15Hp@480V
10Hp@600V
2.0Hp@120V
3Hp@240V
7.5Hp@240V
20Hp@480V
10Hp@600V
3.0Hp@120V
5Hp@240V
7.5Hp@240V
20Hp@480V
10Hp@600V
3.0Hp@120V
7.5Hp@240V
7.5Hp@240V
20Hp@480V
10Hp@600V
3.0Hp@120V
7.5Hp@240V
15Hp@240V
30Hp@480V
5.0Hp@120V
10Hp@240V
20Hp@240V
40Hp@480V
5.0Hp@120V
10Hp@240V
20Hp@240V
50Hp@480V
Eaton.com/bussmannseries
Disconnect
switches
CCPB-3-15CF
Voltage
rating
CUBEFuse
(Class J performance)
12-9
Disconnect switches
12
Description
Features
Agency information
Online resources
Class
CC
CC
CC
J
J
J
J
J
L
L
L
12-10
1007July 2015
Type
LP-CC time-delay, current limiting
FNQ-R time-delay
KTK-R fast-acting
LPJ time-delay, current limiting
JKS fast-acting fuses
DFJ high speed drive fuse
KRP-C time-delay, current limiting
KTU fast-acting
KLU time-delay
Eaton.com/bussmannseries
Data Sheet #
1023
1014
1015
1006 (0-60A)
1007 (70-600A)
1026 (0-60A)
1027 (70-600A)
1048 (0-600A)
1008
1010
1013
Disconnect switches
12
Stranded
RDF30J-3 / RDF60J-3-COMP
RDF60J-3
RDF200J-3
RDF600J-3
RDF30CC-3
RDF30CC-3N
UL 489
CC
30
Compact
Front
RDF30J-3-COMP
RDF30J-3N-COMP
UL 489
J
30
Compact
Front
RDF30J-2
RDF30J-3
RDF30J-4
UL 98
J
30
Standard
Front/Side
Flange
RDF60J-2-COMP
RDF60J-3-COMP
RDF60J-4-COMP
UL 98
J
60
Compact
Front/Side
Flange
RDF60J-2
RDF60J-3
RDF60J-4
UL 98
J
60
Standard
Front/Side
Flange
RDF100J-2
RDF100J-3
RDF100J-4
UL 98
J
100
Standard
Front/Side
Flange
RDF200J-2
RDF200J-3
RDF200J-4
UL 98
J
200
Standard
Front/Side
Flange
RDF400J-2
RDF400J-3
RDF400J-4
UL 98
J
400
Standard
Front/Side
RDF600J-2
RDF600J-3
RDF600J-4
UL 98
J
600
Standard
Front
RDF800L-2
RDF800L-3
RDF800L-4
UL 98
L
800
Standard
Front
600Vac
600Vac
600Vac
250Vdc
600Vac
250Vdc
600Vac
250Vdc
600Vac
250Vdc
600Vac
600Vac
250Vdc
600Vac
600Vdc
600Vac
600Vdc
3
5.0
7.5
3
5.0
7.5
3
3
5.0
7.5
10
7.5
15
15
10
7.5
15
15
10
15
25
30
10
25
50
60
10
50
100
125
75
150
200
75
200
250
7.5
15
20
7.5
15
20
7.5
15
20
15
30
50
15
30
50
30
60
75
60
125
150
125
250
350
200
400
500
200
500
500
3
5
5
10
5
10
7.5
20
20
50
100kA
Integral
75C Cu
100kA
Integral
75C Cu
200kA
Integral
75C Cu
100kA
Integral
75C Cu
200kA
Integral
75C Cu
200kA
Integral
75C Cu
200kA
160 (18)
75C Cu/Al
200kA
310 (35)
75C Cu/Al
200kA
310 (35)
75C Cu/Al
200kA
310 (35)
75C Cu/Al
#14-10
27 (3.1)
#14-10
27 (3.1)
#14-10
27 (3.1)
#14-10
27 (3.1)
#14-10
31 (3.5)
#14-6
31 (3.5)
#14-10
31 (3.5)
#14-6
31 (3.5)
#12-10
35.4 (4)
#12-1
35.4 (4)
#12-10
35.4 (4)
#12-1
35.4 (4)
#6-300MCM
275 (31)
#4-600MCM
550 (62)
Dual 1/0-250MCM
550 (62)
(2) #2-600MCM
375 (42.4)
(2) #2-600MCM
375 (42.4)
10,000
10,000
10,000
10,000
8000
6000
5000
5000
3.0 (1.3)
3.8 (1.7)
4.7 (2.1)
3.1 (1.4)
4.1 (1.8)
4.8 (2.2)
4.0 (1.8)
5.3 (2.4)
X.X (2.9)
4.07 (1.8)
5.3 (2.4)
6.49 (2.9)
5.7 (2.6)
7.8 (3.5)
10.8 (4.9)
11.4 (5.2)
16.6 (7.6)
21.8 (9.9)
31.7 (14.4)
44.2 (20.1)
56.8 (25.8)
31.7 (14.4)
44.2 (20.1)
56.8 (25.8)
-20C to 70C
UL 94-V0
-20C to 70C
UL 94-V0
-20C to 70C
UL 94-V0
-20C to 70C
UL 94-V0
-20C to 70C
UL 94-V0
-20C to 70C
UL 94-V0
-20C to 70C
UL 94-V0
-20C to 70C
UL 94-V0
Integral
Integral
Integral
Integral
10x10
Not Required
10x10
Not Required
10x10
Not Required
10x10
Not Required
10x10
10x10
12X12
12X12
600
10
600
10
600
10
600
10
600
10
600
10
600
10
600
10
Mechanical characteristics
Endurances/cycles
10,000
10,000
Physical characteristics
Dimensions
See drawings on
product pages
Weight - Lbs (KG)
2-pole
3-pole
1.3 (0.6)
1.4 (0.6)
3-pole + neutral
1.4 (0.6)
1.5 (0.7)
4-pole
Environmental
Operating temp. range
-20C to 70C
-20C to 70C
Flammability rating
UL 94-V0
UL 94-V0
Accessories
Lug Kit
Integral
Integral
Handles Direct
Front selector
Front pistol
Side pistol
Flange
Cable
Shaft
Shafts c/s - mm
5x5
5x5
Terminal shrouds
Not Required
Not Required
Auxiliary contacts
(1) NO
(1) NC
AC ratings
Volts
600
600
Amps
10
10
Available, see product page for details and part numbers.
Not available.
* General purpose only, not photovoltaic rated.
1007July 2015
Eaton.com/bussmannseries
Disconnect
switches
UL electrical ratings
Max AC volts
Max DC volts*
Std AC horsepower ratings
1-phase, 240Vac
3-phase, 240Vac
3-phase, 480Vac
3-phase, 600Vac
Max AC horsepower ratings
3-phase, 240Vac
3-phase, 480Vac
3-phase, 600Vac
DC horsepower ratings
125Vdc
250Vdc
Electrical characteristics
SCCR
Terminal lugs/kits
Mounting torque - Lb-In (Nm)
Wire type
Wire range and
Torque - Lb-In (Nm)
Solid
RDF30CC-3
12-11
Disconnect switches
12
Switch
Amp
rating
30
30
30
30
*
Fuse
class
CC
CC
J
J
Number
of poles
3
3 + Ntrl*
3
3 + Ntrl*
SCCR
100kA
100kA
100kA
100kA
Neutral is switched.
Wire
size
#14-10 Sol/Str
#14-10 Sol/Str
#14-10 Sol/Str
#14-10 Sol/Str
Wire
type
75C Cu
75C Cu
75C Cu
75C Cu
Color
Black
Black
Test
function
Y
Y
or
Part
number
DIR-05
DIR-06
Padlockable
Y
Y
Test
function
N
N
Color
Black
Red/yellow
Mounting depth
(X) in (mm)
4.02~9.65 (102~245)
4.02~14.37 (102~365)
4.02~17.52 (102~445)
or
Padlockable
Y
Y
Defeatable
Y
Y
NEMA
type
1, 3R, 12
1, 3R, 12
1, 3R, 4, 4X,
1, 3R, 4, 4X,
1, 3R, 4, 4X,
1, 3R, 4, 4X,
or
12
12
12
12
Color
Black
Red/yellow
Black
Red/yellow
Black
Red/yellow
Test
function
N
N
N
N
Y
Y
Padlockable
Y
Y
Y
Y
Y
Y
Defeatable
Y
Y
Y
Y
Y
Y
Part
number
H12-05B
H12-05R
H4X-05B
H4X-05R
H4X-05TB
H4X-05TR
NEMA
type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Test
function
N
N
Padlockable
Y
Y
Defeatable
Y
Y
Part
number
H4X-05BHD
H4X-05RHD
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
Mounting depth
(X) in (mm)
4.02~9.65 (102~245)
4.02~14.37 (102~365)
4.02~17.52 (102~445)
or
Part
number
SH2-200
SH2-320
SH2-400
NFPA through the door handle kit - to be used with front pistol handle
Test
function
N
Auxiliary contacts
Accessories
Color
Red
12-12
Part
number
H4X-04B
H4X-04R
Part
number
SH1-200
SH1-320
SH1-400
Handle
Part
number
RDF30CC-3
RDF30CC-3N
RDF30J-3-COMP
RDF30J-3N-COMP
(1)
(2)
Auxillary contacts
Contact
type
NO
NC
Auxillary
Contact
Holder
Number of
contacts
1
1
and
Continuous
amp rating
10A
10A
Voltage
rating
600Vac
600Vac
Padlockable
Y
Defeatable
N
1007July 2015
Eaton.com/bussmannseries
Part
number
H79-1
Part
number
BAC05(1)
BAC06(1)
BAC-HOLDER2(2)
Disconnect switches
12
3.28
83.3
3.78
96 1.47
37.5
0.59
15
3.3
84
4.56
116
1
25.5
1.12
28.5
5.19 (131.8)
4.13
105
1.47
37.5
0.59
15
Disconnect
switches
1.12
28.5
3.3
84
4.56
116
3.89
99
1
25.5
RDF30J-_-COMP
I
9
H4X-04_
1.45
37
1.22
31
0.11
3
4 0.27
47
1.10
28
3.46
88
3.07
78
0.53
13.5
0.88
22.5
1.73
44
0.78
20
TEST
0.78
20
H4X-05__
H12-05__
1.46
37
4 0.27
47
65
2.75
70
90
3.07
78
0.55
14
0.55
14
1007July 2015
Eaton.com/bussmannseries
12-13
Disconnect switches
12
Standard Class J
SWITCH
Amp
rating
30
200kA
30
200kA
7.5
15
20
30
200kA
7.5
15
20
Wire
size
#14-10 Sol
#14-6 Str
#14-10 Sol
#14-6 Str
#14-10 Sol
#14-6 Str
+
Direct mount handle - mounts directly to switch, no shaft required
Wire
type
Part
number
75C Cu
RDF30J-2
75C Cu
RDF30J-3
75C Cu
RDF30J-4
For switch
Part number
All switches
Color
Black
Test
function
Y
Padlockable
Y - On Switch
Part
number
DIR-07
NEMA
type
1, 3R, 12
1, 3R, 12
1, 3R, 4, 4X,
1, 3R, 4, 4X,
1, 3R, 4, 4X,
1, 3R, 4, 4X,
12
12
12
12
Color
Black
Red/yellow
Black
Red/yellow
Black
Red/yellow
Test
function
N
N
N
N
Y
Y
Padlockable
Y
Y
Y
Y
Y
Y
Defeatable
Y
Y
Y
Y
Y
Y
Part
number
H12-05B
H12-05R
H4X-05B
H4X-05R
H4X-05TB
H4X-05TR
NEMA
type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Test
function
N
N
Padlockable
Y
Y
Defeatable
Y
Y
Part
number
H4X-05BHD
H4X-05RHD
NEMA
type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Test
function
N
N
Padlockable
Y
Y
Defeatable
N/A
N/A
Part
number
H4X-05SB
H4X-05SR
or
External front operated pistol handles - shaft required
or
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
External right side operated pistol handles - shaft required
Handle
Mounting depth
(X) in (mm)
5.30~9.06 (135~230)
5.30~13.78 (135~350)
5.30~16.93 (135~430)
Part
number
SH5-200
SH5-320
SH5-400
or
Flange handle(1) - requires shaft operated mechanism or cable operated mechanism + cable
(1)
(2)
NEMA
type
1, 3R, 4, 12
1, 3R, 4, 4X, 12
Flange
style
Standard
Chrome Plated
Test
function
N
N
(4)
Padlockable
Y
Y
Defeatable
Y
Y
For enclosure
depth - in (mm)
6~24 (152~613)
Part
number
FLRM
Item / length
Cable mechanism
36 (900mm) cable
60 (1500mm) cable
120 (3000mm) cable
Part
number
FLCM
FLC36
FLC60
FLC120
Cable operated flange mechanism and cable - must select mechanism(3) and cable(4)
or
NFPA through the door handle kit - to be used with front pistol handle
Test
function
N
Color
Red
12-14
Part
number
FLH1
FLH2
1007July 2015
Padlockable
Y
Eaton.com/bussmannseries
Defeatable
N
Part
number
H79-2
Disconnect switches
12
Standard Class J
Aux contacts
Auxillary contacts
Acc.
Contact
type
NO
NC
Number of
contacts
1
1
Dimensions in (mm)
and
Continuous
amp rating
10A
10A
Voltage
rating
600Vac
600Vac
5.87
149.3
1.41
36
1.46
37.2
Part
number
BAC05
BAC06
4.84
123
4.02
102.1
5.35
136
2.68
68.07
1.41
36
Disconnect
switches
Flange handle
1.79
45.5
3.50
(88.9)
0.28
(7.1)
0.50
1.55
(39.4)
(12.7)
2.16
(54.9)
5.31
135
0.86
(21.8)
1.06
(26.9)
5.66
(143.8)
6.22
(158.0)
4.68
(118.9)
1.00
(25.4)
1.00 0.88
(25.4) (22.3)
DIR-07
2.32
(58.9)
7.10
(180.3)
2.70
(68.6)
FLH_
0
0.78
20
1.73
44
1.46
37
4 0.27
47
65
2.75
70
H4X-05__
H12-05__
90
90
3.07
78
0.78
20
Handle type
0.55
14
TEST
0.55
14
1007July 2015
Eaton.com/bussmannseries
12-15
Disconnect switches
12
Compact Class J
Switch
Amp
rating
Fuse Number
class of poles SCCR
60
100kA
10
10
60
100kA
15
30
50
10
60
100kA
15
30
50
10
Wire
size
#14-10 Sol
#14-6 Str
#14-10 Sol
#14-6 Str
#14-10 Sol
#14-6 Str
Wire
type
75C Cu
RDF60J-2-COMP
75C Cu
RDF60J-3-COMP
75C Cu
RDF60J-4-COMP
Part
number
DIR-07
For switch
Part number
All switches
Color
Black
Test
function
Y
Padlockable
Y - on switch
NEMA
type
1, 3R, 12
1, 3R, 12
1, 3R, 4, 4X,
1, 3R, 4, 4X,
1, 3R, 4, 4X,
1, 3R, 4, 4X,
12
12
12
12
Color
Black
Red/yellow
Black
Red/yellow
Black
Red/yellow
Test
function
N
N
N
N
Y
Y
Padlockable
Y
Y
Y
Y
Y
Y
Defeatable
Y
Y
Y
Y
Y
Y
Part
number
H12-05B
H12-05R
H4X-05B
H4X-05R
H4X-05TB
H4X-05TR
NEMA
type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Test
function
N
N
Padlockable
Y
Y
Defeatable
Y
Y
Part
number
H4X-05BHD
H4X-05RHD
NEMA
type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Test
function
N
N
Padlockable
Y
Y
Defeatable
N/A
N/A
Part
number
H4X-05SB
H4X-05SR
or
External front operated pistol handles - shaft required
or
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
External right side operated pistol handles - shaft required
Handle
Part
number
Mounting depth
(X) in (mm)
5.30~9.06 (135~230)
5.30~13.78 (135~350)
5.30~16.93 (135~430)
Part
number
SH5-200
SH5-320
SH5-400
or
Flange handle(1) - requires shaft operated mechanism or cable operated mechanism + cable
(1)
(2)
(3)
(4)
NEMA
type
1, 3R, 4, 12
1, 3R, 4, 4X, 12
Flange
style
Standard
Chrome Plated
Test
function
N
N
Padlockable
Y
Y
Defeatable
Y
Y
Part
number
FLH1
FLH2
For enclosure
Depth - in (mm)
6~24 (152~613)
Part
number
FLRM
Item / length
Cable mechanism
36 (900mm) cable
60 (1500mm) cable
120 (3000mm) cable
Part
number
FLCM
FLC36
FLC60
FLC120
Cable operated flange mechanism and cable - must select mechanism(3) and cable(4)
or
NFPA through the door handle kit - to be used with selector handle or front pistol handle
Test
function
N
Color
Red
12-16
1007July 2015
Padlockable
Y
Eaton.com/bussmannseries
Defeatable
N
Part
number
H79-2
Disconnect switches
12
Compact Class J
Aux contacts
Auxillary contacts
Acc.
Contact
type
NO
NC
Number of
contacts
1
1
Dimensions in (mm)
and
Continuous
amp rating
10A
10A
Voltage
rating
600Vac
600Vac
5.87
149.3
1.41
36
1.46
37.2
Part
number
BAC05
BAC06
4.84
123
4.02
102.1
Disconnect
switches
5.35
136
2.68
68.07
1.41
36
Flange handle
1.79
45.5
3.50
(88.9)
0.28
(7.1)
0.50
1.55
(39.4)
(12.7)
2.16
(54.9)
5.31
135
0.86
(21.8)
1.06
(26.9)
5.66
(143.8)
6.22
(158.0)
4.68
(118.9)
1.00
(25.4)
1.00 0.88
(25.4) (22.3)
DIR-07
2.32
(58.9)
7.10
(180.3)
2.70
(68.6)
FLH_
I
90
0
0.78
20
1.73
44
1.46
37
4 0.27
47
65
2.75
70
H4X-05__
H12-05__
90
3.07
78
0.78
20
Handle type
0.55
14
TEST
0.55
14
1007July 2015
Eaton.com/bussmannseries
12-17
Disconnect switches
12
Standard Class J
SWITCH
Amp
rating
60
200kA
10
10
60
200kA
15
30
50
10
60
200kA
15
30
50
10
Wire
size
#12-10 Sol
#12-1 Str
#12-10 Sol
#12-1 Str
#12-10 Sol
#12-1 Str
Wire
type
75C Cu
RDF60J-2
75C Cu
RDF60J-3
75C Cu
RDF60J-4
Color
Black
Test
function
Y
Padlockable
Y
Part
number
DIR-07
NEMA
type
1, 3R, 12
1, 3R, 12
1, 3R, 4, 4X,
1, 3R, 4, 4X,
1, 3R, 4, 4X,
1, 3R, 4, 4X,
12
12
12
12
Color
Black
Red/yellow
Black
Red/yellow
Black
Red/yellow
Test
function
N
N
N
N
Y
Y
Padlockable
Y
Y
Y
Y
Y
Y
Defeatable
Y
Y
Y
Y
Y
Y
Part
number
H12-03B
H12-03R
H4X-06B
H4X-06R
H4X-06TB
H4X-06TR
NEMA
type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Test
function
N
N
Padlockable
Y
Y
Defeatable
Y
Y
Part
number
H4X-06BHD
H4X-06RHD
NEMA
type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Test
function
N
N
Padlockable
Y
Y
Defeatable
N/A
N/A
Part
number
H4X-06SB
H4X-06SR
or
External front operated pistol handles - shaft required
or
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
External right side operated pistol handles - shaft required
HANDLE
Mounting depth
(X) in (mm)
5.30~9.06 (135~230)
5.30~13.78 (135~350)
5.30~16.93 (135~430)
Part
Number
SH5-200
SH5-320
SH5-400
or
Flange handle(1) - requires shaft operated mechanism or cable operated mechanism + cable
(1)
(2)
NEMA
type
1, 3R, 4, 12
1, 3R, 4, 4X, 12
Flange
style
Standard
Chrome Plated
Test
Function
N
N
(3)
(4)
12-18
Part
number
Padlockable
Y
Y
Defeatable
Y
Y
Part
number
FLH1
FLH2
Part
number
FLRM
Item / length
Cable mechanism
36 (900mm) cable
60 (1500mm) cable
120 (3000mm) cable
Part
number
FLCM
FLC36
FLC60
FLC120
Cable operated flange mechanism and cable - must select mechanism(3) and cable(4)
1007July 2015
Eaton.com/bussmannseries
Disconnect switches
12
Standard Class J
or
Select
NFPA handle
NFPA through the door handle kit - to be used with front pistol handle
Color
Red
Aux contacts
Auxillary contacts
Acc.
Contact
type
NO
NC
Dimensions in (mm)
Number of
contacts
1
1
Test
function
N
and
Continuous
amp rating
10A
10A
Padlockable
Y
Voltage
rating
600Vac
600Vac
5.87
149.3
1.41
36
Defeatable
N
Part
number
BAC05
BAC06
4.81
122.2
1.41
36
5.23
133
6.77
172
Flange handle
1.79
45.5
3.50
(88.9)
0.28
(7.1)
0.50
1.55
(39.4)
(12.7)
2.16
(54.9)
5.31
135
0.86
(21.8)
1.06
(26.9)
5.66
(143.8)
6.22
(158.0)
4.68
(118.9)
1.00
(25.4)
1.00 0.88
(25.4) (22.3)
DIR-07
7.10
(180.3)
2.32
(58.9)
FLH_
External front and right side pistol handle
Handle type
90
1.46
37
4 0.27
47
1.77
45
0.78
20
65
4.92
125
3.07
78
H4X-06__
H12-03__
2.70
(68.6)
0.78
20
1.57
40
Disconnect
switches
7.32
186
3.66
92.96
1.46
37.2
Part
number
H79-2
TEST
0.55
14
1007July 2015
0.55
14
Eaton.com/bussmannseries
12-19
Disconnect switches
12
Standard Class J
Switch
Amp
rating
Fuse
class
100
200kA
10
7.5
20
100
200kA
30
60
75
7.5
20
100
200kA
30
60
75
7.5
20
Wire
Wire
size
type
#12-10 Sol
75C Cu
#12-1 Str
#12-10 Sol
75C Cu
#12-1 Str
#12-10 Sol
75C Cu
#12-1 Str
For switch
part number
All switches
Color
Black
or
Test
function
Y
RDF100J-4
NEMA
type
1, 3R, 12
1, 3R, 12
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Black
Red/yellow
Black
Red/yellow
Test
function
N
N
N
N
Y
Y
Padlockable
Y
Y
Y
Y
Y
Y
Defeatable
Y
Y
Y
Y
Y
Y
Part
number
H12-03B
H12-03R
H4X-06B
H4X-06R
H4X-06TB
H4X-06TR
NEMA
type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Test
function
N
N
Padlockable
Y
Y
Defeatable
Y
Y
Part
number
H4X-06BHD
H4X-06RHD
NEMA
type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Test
function
N
N
Padlockable
Y
Y
Defeatable
N/A
N/A
Part
number
H4X-06SB
H4X-06SR
Handle
RDF100J-3
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
Length
in (mm)
7.9 (200)
12.6 (320)
15.7 (400)
Mounting depth
(X) in (mm)
5.30~9.06 (135~230)
5.30~13.78 (135~350)
5.30~16.93 (135~430)
Part
number
SH5-200
SH5-320
SH5-400
or
Flange handle(1) - requires shaft operated mechanism or cable operated mechanism + cable
(1)
(2)
NEMA
type
1, 3R, 4, 12
1, 3R, 4, 4X, 12
Flange
style
Standard
Chrome plated
Test
function
N
N
(3)
(4)
12-20
RDF100J-2
Part
number
DIR-07
Padlockable
Y
or
Part
number
Padlockable
Y
Y
Defeatable
Y
Y
Part
number
FLH1
FLH2
Part
number
FLRM
Item / length
Cable mechanism
36 (900mm) cable
60 (1500mm) cable
120 (3000mm) cable
Part
number
FLCM
FLC36
FLC60
FLC120
Cable operated flange mechanism and cable - must select mechanism(3) and cable(4)
1007July 2015
Eaton.com/bussmannseries
Disconnect switches
12
Standard Class J
or
Select
NFPA handle
NFPA through the door handle kit - to be used with front pistol handle
Color
Red
Aux contacts
Auxillary contacts
Acc.
Contact
type
NO
NC
Number of
contacts
1
1
and
Continuous
amp rating
10A
10A
Test
function
N
Voltage
rating
600Vac
600Vac
Dimensions in (mm)
Padlockable
Y
Defeatable
N
5.87
149.3
1.41
36
Part
number
BAC05
BAC06
4.81
122.2
1.41
36
5.23
133
6.77
172
Flange handle
Disconnect
switches
7.32
186
3.66
92.96
1.46
37.2
Part
number
H79-2
1.79
45.5
3.50
(88.9)
0.86
(21.8)
5.31
135
0.28
(7.1)
0.50
1.55
(39.4)
(12.7)
2.16
(54.9)
1.06
(26.9)
5.66
(143.8)
6.22
(158.0)
4.68
(118.9)
1.00
(25.4)
1.00 0.88
(25.4) (22.3)
DIR-07
2.32
(58.9)
7.10
(180.3)
2.70
(68.6)
FLH_
90
90
1.46
37
4 0.27
47
1.77
45
0.78
20
65
4.92
125
3.07
78
H4X-06__
H12-03__
0.78
20
Handle type
TEST
0.55
14
1007July 2015
0.55
14
Eaton.com/bussmannseries
12-21
Disconnect switches
12
Standard Class J
HANDLE
SWITCH + LUGS
Switch
Amp
rating
200
200
200
400
400
400
Fuse
class
J
J
J
J
J
J
Number
of poles
2
3
4
2
3
4
SCCR
200kA
200kA
200kA
200kA
200kA
200kA
1-phase
220/
240Vac
10
10
-
DC*
250
Vdc
50
50
50
Switch
amp rating
200
200
200
Number
of poles
2
3
4
Lugs
Per kit
2
3
4
400
400
400
Wire range
#6-300MCM
#6-300MCM
#6-300MCM
#4-600MCM or
Dual 1/0-250MCM
#4-600MCM or
Dual 1/0-250MCM
#4-600MCM or
Dual 1/0-250MCM
Wire type
75C Cu/Al
75C Cu/Al
75C Cu/Al
Part
number
LUG1-2
LUG1-3
LUG1-4
75C Cu/Al
LUG2-2
75C Cu/Al
LUG2-3
75C Cu/Al
LUG2-4
Color
Black
Test
function
Y
Padlockable
Y
Part
number
DIR-07
NEMA
type
1, 3R, 12
1, 3R, 12
1, 3R, 4, 4X,
1, 3R, 4, 4X,
1, 3R, 4, 4X,
1, 3R, 4, 4X,
12
12
12
12
Color
Black
Red/yellow
Black
Red/yellow
Black
Red/yellow
Test
function
N
N
N
N
Y
Y
Padlockable
Y
Y
Y
Y
Y
Y
Defeatable
Y
Y
Y
Y
Y
Y
Part
number
H12-03B
H12-03R
H4X-06B
H4X-06R
H4X-06TB
H4X-06TR
NEMA
type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Test
function
N
N
Padlockable
Y
Y
Defeatable
Y
Y
Part
number
H4X-06BHD
H4X-06RHD
NEMA
type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Test
function
N
N
Padlockable
Y
Y
Defeatable
N/A
N/A
Part
number
H4X-06SB
H4X-06SR
or
External front operated pistol handles - shaft required
or
Part
number
RDF200J-2
RDF200J-3
RDF200J-4
RDF400J-2
RDF400J-3
RDF400J-4
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
External right side operated pistol handles - shaft required
Shafts for pistol handles
Length
in (mm)
7.9 (200)
12.6 (320)
15.7 (400)
12-22
125
Vdc
20
20
20
Mounting depth
(X) in (mm)
200A: 5.70-9.06 (145-230)
400A: 7.87-10.24 (200-260)
200A: 5.70-13.78 (145-350)
400A: 7.87-16.93 (200-380)
200A: 5.70-16.93 (145-430)
400A: 7.87-18.10 (200-460)
1007July 2015
Part
number
SH5-200
SH5-320
X
Eaton.com/bussmannseries
SH5-400
Disconnect switches
12
Standard Class J
or
Flange handle(1) 200A only - requires shaft operated mechanism or cable operated mechanism + cable
(1)
(2)
NEMA
type
1, 3R, 4, 12
1, 3R, 4, 4X, 12
Flange
style
Standard
Chrome plated
Test
function
N
N
Padlockable
Y
Y
Part
number
FLH1
FLH2
Part
number
FLRM
Item
Cable mechanism
36 (900mm) cable
60 (1500mm) cable
120 (3000mm) cable
Part
number
FLCM
FLC36
FLC60
FLC120
Cable operated flange mechanism and cable 200A only - must select Mechanism(3) and Cable(4)
(3)
Handle
Defeatable
Y
Y
(4)
or
NFPA through the door handle kit - to be used with front pistol handle
Color
Red
Red
Aux contacts
Shrouds
Auxillary contacts
Contact
type
NO
NC
Switch Amp
rating
200
200
200
400
400
400
Number of
contacts
1
1
and
Continuous
amp rating
10A
10A
Test
function
N
N
Voltage
rating
600Vac
600Vac
Defeatable
N
N
Part
number
H79-2
H79-3
Part
number
BAC05
BAC06
Padlockable
Y
Y
Accessories
and
Terminal shrouds - includes terminal shroud for Lineside or loadside
Dimensions in (mm)
RDF200J-3
Number
of poles
2
3
4
2
3
4
Disconnect
switches
Use with
switch
RDF200J-_
RDF400J-_
Part
number
TSH8-2TB
TSH8-3TB
TSH8-4TB
TSH9-2TB
TSH9-3TB
TSH9-4TB
RDF400J-3
7.72
196.2
7.08
180
6.61
168
4.37
111.1
9.44
240
15.35
390
7.97
202.5
3.98
101.25
11.46
291.3
7.67
195
6.50
165.2
5.28
134.2
3.98
101.25
2.95
75
6.18
157
0.98
24.9
5.11
130
2.95
75
1.41
36
1.96
50
3.26
83
2.59
66
1007July 2015
Eaton.com/bussmannseries
2.59
66
12-23
Disconnect switches
12
Standard Class J
Direct mount handle
1.57
40
Flange handle
1.79
45.5
3.50
(88.9)
0.28
(7.1)
0.50
1.55
(39.4)
(12.7)
2.16
(54.9)
5.31
135
0.86
(21.8)
1.06
(26.9)
5.66
(143.8)
6.22
(158.0)
4.68
(118.9)
1.00
(25.4)
1.00 0.88
(25.4) (22.3)
DIR-07
2.32
(58.9)
7.10
(180.3)
2.70
(68.6)
FLH_
90
1.77
45
0.78
20
H4X-06__
H12-03__
TEST
0.55
14
Terminal lugs
0.4
4.7
1.3
35
LUG1-__
12-24
1.8
46
0.25
6.35
1.12
28.6
200A
2.8
71.5
0.46
11.68
0.63
15.88
0.44
11.13
1
25
0.45
11.6
1.52
38.8
1.46
37
4 0.27
47
65
4.92
125
90
3.07
78
0.78
20
Handle type
400A
LUG2-__
1007July 2015
Eaton.com/bussmannseries
0.55
14
Disconnect switches
12
Standard Class J
Handle
Amp
rating
600
600
600
800
800
800
Fuse Number
class of poles
J
2
J
3
J
4
L
2
L
3
L
4
SCCR
200kA
200kA
200kA
200kA
200kA
200kA
Switch
amp rating
600-800
600-800
600-800
Number
of poles
2
3
4
Lugs
per kit
2
3
4
Wire range
(2) #2-600MCM
(2) #2-600MCM
(2) #2-600MCM
Wire type
75C Cu/Al
75C Cu/Al
75C Cu/Al
Test
function
Y
Padlockable
Y
NEMA
type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Test
function
N
N
Padlockable
Y
Y
Defeatable
Y
Y
Part
number
H4X-07B
H4X-07R
Part
number
DIR-08
NEMA
type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Test
function
N
N
Padlockable
Y
Y
Defeatable
Y
Y
Part
number
H4X-07BHD
H4X-07RHD
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
Shafts for pistol handles
Length
in (mm)
7.9 (200)
12.6 (320)
15.7 (400)
Mounting depth
(X) in (mm)
10.63~11.97 (270~304)
10.63~16.69 (270~424)
10.63~19.84 (270~504)
or
Part
number
SH7-200
SH7-320
SH7-400
NFPA through the door handle kit - to be used with front pistol handle
Accessories
Aux contacts
For switch
part number
All switches
Shrouds
Part
number
LUG5-2
LUG5-3
LUG5-4
Color
Black
or
External front operated pistol handles - shaft required
or
Part
number
RDF600J-2
RDF600J-3
RDF600J-4
RDF800L-2
RDF800L-3
RDF800L-4
Disconnect
switches
Switch + lugs
Switch
Color
Red
Auxillary contacts
Contact
type
NO
NC
Number of
contacts
1
1
and
Continuous
amp rating
10A
10A
Test
function
N
Voltage
rating
600Vac
600Vac
Padlockable
Y
Defeatable
N
and
Terminal shrouds - includes terminal shroud for Lineside or loadside
Switch amp
rating
600-800
600-800
600-800
Number
of poles
2
3
4
1007July 2015
Eaton.com/bussmannseries
Part
number
H79-4
Part
number
BAC05
BAC06
Part
number
TSH10-2TB
TSH10-3TB
TSH10-4TB
12-25
Disconnect switches
12
min 10.43
min 265
9.84
250
6.10
155
0.43
11
14.96
380
Fuse Cover Fully Open
18.58
472
3.36
85.5
0.27
7
11.81
300
18.54
471
0.27
7
3.54
90
11.81
300
10.23
260
fix 9.84
fix 250
5
126.5
0.27
7
3.36
85.5
3.12
79.5
2.32
59
0.51
13
0.35
9
2
51 3.7
3.7
94
94
14.33 (3P) - 18.03 (4P)
364 (3P) - 458 (4P)
DIR-08
Terminal lugs
3.76
95.5
Handle type
1.46
37
0.40
10.2
0.78
20
4 0.27
47
3.15
80
61
0.55
14
0.55
14
0.64
16.2
H4X-07__
2.87
73
0.78
20
210
90
600 to 800A
LUG5-__
12-26
1007July 2015
Eaton.com/bussmannseries
Disconnect switches
12
Features
Agency information
Fuse blocks
Data Sheet #
Modular knifeblade fuse blocks 100-600A
3192
Class J power distribution fuse blocks 100-400A
10192
Fuses holders
CH Class CC, midget and 10x38 0-30A
3185
Finger-safe Optima holders 0-30A
1102
Optima protection modules 0-30A
1109
CH Class J 0-60A
2144
RD600-3
RD200-3
Part number
3-pole
RD30-3
RD60-3
RD100-3
RD100-3-SCCR
RD200-3
4-pole
RD200-4
Thermal current Ith @ 40C (A)
30
60
100
100
200
Rated insulation voltage Ui (V)
800
800
800
1000
1000
Rated impulse withstand voltage Uimp (kV)
8
8
8
8
8
Rated operation currents Ie (A)
(1)
(1)
(1)
(1)
Rated voltage
Load duty category
A
A
A
A
A (1)
400Vac
AC-22 A
32
63
100
100
200
400Vac
AC-23 A
32
63
100
100
200
690Vac
AC-22 A
32
63
80
100
200
690Vac
AC-23 A
32
63
63
100
200
Operational power (Vac) in AC-23 (kW)
(1)(2)
400V w/o prebreak AC
15
30
45
51
100
15
30
45
63
140
500V w/o prebreak AC (1)(2)
690V w/o prebreak AC (1)(2)
18.5
30
45
90
185
Overload capacity (Ue 415Vac)
Rated short-circuit
making capacity Icm(kA peak) (3)
12
12
12
17.6
32
Fuse protected short-circuit withstand
(kA rms prospective)
Short-circuit current (kA) (3)
50
50
25
200
200
Associated fuse rating (A) (3)
32
63
100
100
200
Connection
2
Minimum Cu cable cross section (mm )
2.5
2.5
10
35
70
Minimum Cu busbar section (mm2)
RD400-3
RD400-4
400
1000
8
RD600-3
RD600-4
1000
12
RD800-3
RD800-4
1000
12
RD1000-3
RD1000-4
1000
12
RD1200-3
RD1200-4
1000
12
A (1)
400
400
400
315
A (1)
630
630
500
200
A (1)
800
800
630
400
A (1)
1000
1000
630
400
A (1)
1200
1000
630
400
220
280
185
355
450
185
450
560
400
560
560
400
560
560
400
48
48
75
48
75
200
400
100
630
100
800
100
1000
100
1250
185
600
2x150
2x30x5
2x185
2x40x5
2x240
2x50x5
2x60x5
1007July 2015
Eaton.com/bussmannseries
12-27
Disconnect
switches
Online resources
Disconnect switches
12
UL electrical specifications
Part number
3-pole
4-pole
UL standard
Max ampacity
Switch type
Handle operation
UL electrical ratings
Max voltage (AC)
Max voltage (DC)
Maximum AC horsepower ratings
1-phase, 120Vac
1-phase, 240Vac
3-phase, 240Vac
3-phase, 480Vac
3-phase, 600Vac
DC horsepower ratings
125Vdc
250Vdc
Electrical characteristics
SCCR with fuse
Fuse class
Max. fuse rating
Terminal lugs/kits
Lug mounting torque - Lb-In (Nm)
Wire type
Wire range and Torque - Lb-In (Nm)
Solid
Stranded
RD30-3
RD200-3
RD30-3
UL 98
30A
Compact
Front/Side
RD60-3
UL 98
60A
Compact
Front/Side
RD100-3
UL 98
100A
Compact
Front/Side
RD100-3-SCCR
UL 98
100A
Standard
Front
RD200-3
RD200-4
UL 98
200A
Standard
Front
RD400-3
RD400-4
UL 98
400A
Standard
Front
RD600-3
RD600-4
UL 98
600A
Standard
Front
RD800-3
RD800-4
UL 98
800A
Standard
Front
RD1000-3
RD1000-4
UL 98
1000A
Standard
Front
RD1200-3
RD1200-4
UL 98
1200A
Standard
Front
600Vac
600Vac
600Vac
600Vac
250Vdc
600Vac
250Vdc
600Vac
600Vac
250Vdc
600Vac
600Vac
600Vac
2
5
10
20
25
3
10
20
40
50
5
10
20
50
50
10
30
75
100
10
75
150
200
125
250
350
200
400
350
200
500
500
200
500
500
200
500
500
20
50
100kA
J
30A
Integral
-
100kA
J
60A
Integral
-
25kA/100kA*
J
100A
Integral
-
200kA
J
100A
160 (18)
200kA
J
200A
160 (18)
200kA
J
600A
310 (35)
100kA
L
800A
310 (35)
100kA
L
1000A
310 (35)
100kA
L
1200A
310 (35)
75C Cu
75C Cu
75C Cu
75C Cu/Al
75C Cu/Al
200kA
J
400A
75C Cu/Al
75C Cu/Al
75C Cu/Al
75C Cu/Al
#12-10
35.4 (4)
#10-1
35.4 (4)
1/0
39.8 (4.5)
2/0
44.3 (5)
#12-10
35.4 (4)
#10-1
35.4 (4)
1/0
39.8 (4.5)
2/0
44.3 (5)
#12-10
35.4 (4)
#10-1
35.4 (4)
1/0
39.8 (4.5)
2/0
44.3 (5)
#6-300MCM
275 (31)
#6-300MCM
275 (31)
LUG2-_ #4-600MCM
550 (62)
Dual 1/0-250MCM
550 (62)
LUG3-_:(2) #6-2
200 (22.6)
(2) #1-350MCM
375 (42.4)
(2) #2-600MCM
375 (42.4)
10,000
8000
6000
6000
3500
3500
3500
4.2 (1.91)
4.2 (1.91)
5.0 (2.3)
10.0 (4.6)
12.3 (5.6)
18.1 (8.2)
23.9 (10.9)
19.6 (8.9)
25.3 (11.5)
19.6 (8.9)
25.3 (11.5)
19.6 (8.9)
25.3 (11.5)
-20C to 70C
UL 94-V0
-20C to 70C
UL 94-V0
-20C to 70C
UL 94-V0
-20C to 70C
UL 94-V0
-20C to 70C
UL 94-V0
-20C to 70C
UL 94-V0
-20C to 70C
UL 94-V0
10x10
10x10
10x10
12x12
12x12
12x12
12x12
Mechanical characteristics
Endurances/Cycles
10,000
10,000
10,000
Physical characteristics
Dimensions
See drawings on product pages
Weight - Lbs (KG)
3-pole
1.3 (0.6)
1.3 (0.6)
1.3 (0.6)
4-pole
Environmental
Operating Temperature
-20C to 70C
-20C to 70C -20C to 70C
Flammability Rating
UL 94-V0
UL 94-V0
UL 94-V0
Accessories
Lug Kit Part #
3-pole
Integral
Integral
Integral
4-pole
Handles
NEMA 1, 3R, 12
Direct
Front Pistol
Shaft c/s - mm
5x5
5x5
5x5
Shaft Guide
Shrouds
Auxiliary contacts
NO + NC
(2) NO
12-28
RD600-3
1007July 2015
Eaton.com/bussmannseries
(4) #2-600MCM
375 (42.4)
Disconnect switches
12
Switch
Switch
amp
rating
No. of
poles
SCCR
30
100kA
10
20
25
60
100kA
10
20
40
50
100
25/100kA*
10
20
50
50
Wire
size
#10-2/0 Str
#12-10 Sol
#10-2/0 Str
#12-10 Sol
#10-2/0 Str
#12-10 Sol
Wire
type
Part
number
75C Cu
RD30-3
75C Cu
RD60-3
75C Cu
RD100-3
Color
Black
Padlockable
Y - On Switch
Part
number
DIR-02
Part
number
H4X-01B(1)
H4X-01R(1)
H4X-02B(2)
H4X-02R(2)
or
External front or right side operated selector handles - shaft required
(1)
or
(2)
NEMA
type
1, 3R, 4,
1, 3R, 4,
1, 3R, 4,
1, 3R, 4,
12
12
12
12
Color
Black
Red/yellow
Black
Red/yellow
Handle
length
Short
Short
Long
Long
Test
function
N
N
N
N
Padlockable
Y
Y
Y
Y
NEMA
type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Handle
length
Test
function
N
N
Padlockable
Y
Y
Defeatable
Y
Y
Part
number
H4X-03B
H4X-03R
NEMA
type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Handle
length
Test
function
N
N
Padlockable
Y
Y
Defeatable
Y
Y
Part
number
H4X-03BHD
H4X-03RHD
4X,
4X,
4X,
4X,
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
Handles
+
(1)
(2)
Mounting depth
(X) in (mm)
3.50~7.60 (89~193)
3.50~9.50 (89~241)
3.50~14.9 (89~378)
Length
in (mm)
7.9 (200)
12.6 (320)
15.7 (400)
Mounting depth
(X) in (mm)
3.30~7.40 (84~188)
3.30~9.30 (84~236)
3.30~14.7 (84~373)
Part
number
SH4-150(1)
SH4-200(1)
SH4-320(1)
Part
number
SH3-200(2)
SH3-320(2)
SH3-400(2)
Part
number
SH-GUIDE1
Required for 12.6 (320mm) long shafts, optional for other lengths
Part
Number
SH-GUIDE2
and
Required for 15.7 (400mm) long shafts, optional for other lengths
Accs
Aux contacts
Disconnect
switches
Test
function
N
Auxillary contacts
Contact
type
NO + NC
NO
Number of
contacts
1 of each
2
Continuous
amp rating
10A
10A
Voltage
rating
240Vac
240Vac
Max number of
Units per switch
2 (1 per side/4 contacts total)
2 (1 per side/4 contacts total)
1007July 2015
Eaton.com/bussmannseries
Part
number
BAC01
BAC02
12-29
Disconnect switches
12
Number
of poles
1 (For switched 4th pole)
3
Location on
switch
Lineside and loadside
Lineside and loadside
and
Switched 4th Pole - converts 3-pole switch to 4-pole
Part
number
POLE98-30
POLE98-60
POLE98-100
1.42
36
1
2
4.90
124.6
0.35 1.02
8.8 26
1.02
26
M5
5.17
131.4
7.44
189
4.90
124.6
2.79
71
2.79
71
0.24
6
1.02 0.35
26 8.8
1. Position for 1 switched 4th pole (1 per device max.) or 1 auxiliary contact.
2. Position for 1 auxiliary contact only.
Note: Maximum of 4 Auxiliary contacts, or 3 Auxiliary contacts + one switched 4th pole.
2.08
53
2.08
53
0.26
6
0.34 1.02
8.8 26
0.26
6
0.34 1.02
8.8 26
1.02
26
M5
1.02
1.02
26
26
M5 0.34
1.02
26 8.8
External front/right side operated selector handle, front operated pistol handle
Handle type
3.07
78
1.57
40
1.42
36
I
9
3.46
88
3.07
78
Selector
H4X-02_
1.22
31
0.11
3
4 0.27
47
Direction of
right side operation
0.88
22.5
1.45
37
0.53
13.5
Direction of
front operation
1.10
28
2.79
71
Selector
H4X-01_
1.57
40
12-30
1.10
28
4 0.27
47
Pistol
H4X-03_
1007July 2015
1.42
36
7.44
189
5.17
131.4
4.91
124.6
1.99
50.6
2.09
53
3.07
78
1.02
26
0.51
13
3.07
1.18 min./7.91 max.
78
30 min./201 max.
1.02
26 1.18 min./7.91 max. 1.42
0.51 30 min./201 max.
36
1
13
Eaton.com/bussmannseries
2.79
71
3.07
78
1.02
26
2.79
71
Dimensions - in (mm)
Part
number
TSH3-1TB
TSH3-3TB
5.17
131.4
7.44
189
Shrouds
Switch amp
rating
30
60
100
Accessories
Switch amp
rating
All switches
All switches
and
Terminal shrouds - includes terminal shroud for both lineside and loadside
0.34
8.8
Disconnect switches
12
Handle
Switch
amp
rating
100
200
200
400
400
No. of
poles
3
3
4
3
4
SCCR
200kA
200kA
200kA
200kA
200kA
Switch
amp rating
100-200
100-200
100-200
400
400
400
400
400
400
No. of
poles
2
3
4
2
3
4
2
3
4
Lugs
per kit
2
3
4
2
3
4
2
3
4
1-phase
220/
240Vac
10
10
10
-
600
Vac
100
200
200
350
350
Wire range
#6-300MCM
#6-300MCM
#6-300MCM
#4-600MCM or Dual 1/0-250MCM
#4-600MCM or Dual 1/0-250MCM
#4-600MCM or Dual 1/0-250MCM
(2) #6-350MCM
(2) #6-350MCM
(2) #6-350MCM
Part
number
RD100-3-SCCR
RD200-3
RD200-4
RD400-3
RD400-4
Wire type
75C Cu/Al
75C Cu/Al
75C Cu/Al
75C Cu/Al
75C Cu/Al
75C Cu/Al
75C Cu/Al
75C Cu/Al
75C Cu/Al
Color
Black
Test
function
N
Padlockable
Y
Part
number
DIR-03
NEMA
type
1, 3R, 12
1, 3R, 12
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Black
Red/yellow
Test
function
N
N
N
N
Padlockable
Y
Y
Y
Y
Defeatable
Y
Y
Y
Y
Part
number
H12-03B
H12-03R
H4X-06B
H4X-06R
NEMA
type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Test
function
N
N
Padlockable
Y
Y
Defeatable
Y
Y
Part
number
H4X-06BHD
H4X-06RHD
or
External front operated pistol handles - shaft required
or
+
+
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
Shafts for pistol handles
Length
in (mm)
7.9 (200)
12.6 (320)
15.7 (400)
Shaft Guide
Mounting depth
(X) in (mm)
5.31~10.43 (135~265)
5.31~15.16 (135~385)
5.31~18.31 (135~465)
Part
number
SH5-200
SH5-320
SH5-400
Part
Number
SH-GUIDE2
and
Required for 15.7 (400mm) long shafts, optional for other lengths
Aux contacts
Accessories
Part
number
LUG1-2
LUG1-3
LUG1-4
LUG2-2
LUG2-3
LUG2-4
LUG3-2
LUG3-3
LUG3-4
Disconnect
switches
Switch + lugs
Switch
Auxillary contacts
Contact
type
NO + NC
NO + NC
NO + NC
NO + NC
Number of
contacts
1 of each
1 of each
1 of each
1 of each
Continuous
amp rating
10.1A
10.1A
1A
1A
Voltage
rating
125-250Vac
125-250Vac
125Vac
125Vac
Part
number
BAC03*
BAC04*
BAC11*
BAC12*
* For one auxiliary contact, install either BAC03 or BAC11. For two auxiliary contacts, install BAC03 + BAC04, or BAC11 + BAC12.
1007July 2015
Eaton.com/bussmannseries
12-31
Disconnect switches
12
Location on
switch
Lineside
Loadside
Lineside or loadside
Lineside
Loadside
Lineside or loadside
Dimensions - in (mm)
Z
Y
1
25
0.45
11.6
R1
2.8
71.5
0.46
11.68
0.63
15.88
0.53
13.46
1.19
30.23
H
T
H
4.22
(107)
4.22
(107)
6.53
(166)
Switch
mounting
J1 3p. J1 4p. K
M 3p. M 4p.
2.17 4.13 1.8
6.3
8.27
(55)
(105) (45.6) (160) (210)
2.17 4.13 1.8
6.3
8.27
(55)
(105) (45.6) (160) (210)
2.95 5.31 2.65 8.26 10.6
(75)
(135) (67.5) (210) (270)
Handle type
R2
0.27
(7)
0.27
(7)
0.27
(7)
Connection
T
U
V
1.97 0.98 1.18
(50) (25) (30)
1.97 0.98 1.18
(50) (25) (30)
2.56 1.77 1.97
(65) (45) (50)
90
1.46
37
4 0.27
47
65
4.92
125
5.31
135
12-32
R1
0.35
(9)
0.35
(9)
0.35
(9)
3.07
78
H4X-06__
H12-03__
N
5.31
(135)
5.31
(135)
7.67
(195)
0.78
20
Switch
body
F 3p. F 4p.
7.09
9.06
(180) (230)
7.09
9.06
(180) (230)
9.05
11.4
(230) (290)
1.77
45
TEST
1007July 2015
0.78
20
DIR-03
1.25
31.75
0.44
11.13
AD
C
1.79
45.5
LUG3-__
LUG2-__
LUG1-__
0.25
6.35
400A
400A
100 to 200A
R2
1.57
40
1.8
46
1.12
28.6
0.25
6.35
AC
AA
CA
1.52
38.8
0.88
2.31 73.15
58.67
0.4
4.7
1.94
49.30
Part
number
TSH4-3T
TSH4-3B
TSH4-4TB
TSH5-3T
TSH5-3B
TSH5-4TB
Terminal lugs
J1
1.3
35
Shrouds
Accessories
Switch amp
rating
100-200A
100-200A
100-200A
400A
400A
400A
0.55
14
Eaton.com/bussmannseries
0.55
14
W
0.43
(11)
0.43
(11)
0.43
(13)
Y
0.14
(3.5)
0.14
(3.5)
0.2
(5)
Z
1.35
(34.4)
1.35
(34.4)
2.08
(53)
AA
6.3
(160)
6.3
(160)
10.2
(260)
AC
0.6
(15)
0.6
(15)
0.8
(20)
Disconnect switches
12
HANDLE
Switch
Amp
rating
600A
600A
800A
800A
1000A
1000A
1200A
1200A
No. of
poles
3
4
3
4
3
4
3
4
220/
240Vac
240
240
200
200
200
200
200
200
SCCR
200kA
200kA
100kA
100kA
100kA
100kA
100kA
100kA
Part
number
RD600-3
RD600-4
RD800-3
RD800-4
RD1000-3
RD1000-4
RD1200-3
RD1200-4
Switch
amp rating
600
600
800-1200
800-1200
No. of
poles
3
4
3
4
Lugs
per kit
3
4
6
8
Lugs required
per pole
1
1
2
2
Wire
range
(2) #2-600MCM
(2) #2-600MCM
(4) #2-600MCM
(4) #2-600MCM
Wire type
75C Cu/Al
75C Cu/Al
75C Cu/Al
75C Cu/Al
(1)
(2)
or
(3)
+
+
(4)
Color
Black
Test
function
N
Padlockable
Y
Part
number
DIR-04
12
12
12
12
Color
Black
Red/yellow
Black
Red/yellow
Test
function
N
N
N
N
Padlockable
Y
Y
Y
Y
Defeatable
Y
Y
Y
Y
Part
number
H4X-07B(1)
H4X-07R(1)
H4X-08B(2)
H4X-08R(2)
12
12
12
12
Color
Black
Red/yellow
Black
Red/yellow
Test
function
N
N
N
N
Padlockable
Y
Y
Y
Y
Defeatable
Y
Y
Y
Y
Part
number
H4X-07BHD(3)
H4X-07RHD(3)
H4X-08BHD(4)
H4X-08RHD(4)
or
External front operated pistol handles - shaft required
NEMA
type
1, 3R, 4,
1, 3R, 4,
1, 3R, 4,
1, 3R, 4,
4X,
4X,
4X,
4X,
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
NEMA
type
1, 3R, 4,
1, 3R, 4,
1, 3R, 4,
1, 3R, 4,
4X,
4X,
4X,
4X,
Shaft guide
Mounting depth
(X) in (mm)
8.70~13.50 (221~343)
8.70~18.23 (221~463)
8.70~21.38 (221~543)
Part
number
SH6-200
SH6-320
SH6-400
Part
number
SH-GUIDE2
and
Required for 15.7 (400mm) long shafts, optional for other lengths
AUX CONTACTS
Accessories
Part
number
LUG5-3
LUG5-4
LUG6-6
LUG6-8
Disconnect
switches
Switch + lugs
Switch
Auxillary contacts
Contact
type
NO + NC
NO + NC
NO + NC
NO + NC
Number of
contacts
1 of each
1 of each
1 of each
1 of each
Continuous
amp rating
10.1A
10.1A
1A
1A
Voltage
rating
125-250Vac
125-250Vac
125Vac
125Vac
Part
number
BAC03*
BAC04*
BAC11*
BAC12*
* For one auxiliary contact, install either BAC03 or BAC11. For two auxiliary contacts, install BAC03 + BAC04, or BAC11 + BAC12.
1007July 2015
Eaton.com/bussmannseries
12-33
Disconnect switches
12
SHROUDS
Switch amp
rating
600A
600A
800-1200A
800-1200A
Number
of poles
3
4
3
4
Location on
switch
Lineside or loadside
Lineside or loadside
Lineside or loadside
Lineside or loadside
800
Terminal
shrouds
B
18.12
(460)
Switch
body
F 3p.
F 4p.
11
14.17
(280)
(360)
18.12
14.64
(372)
14.64
(372)
14.64
(372)
(460)
1000
18.12
(460)
1200
18.12
(460)
19.37
(492)
19.37
(492)
19.37
(492)
800 to 1200A
H
5.5
(140)
J 3p.
5
(127.5)
J 4p.
6.59
(167.5)
Switch
mounting
M 3p.
10.03
(255)
5.5
6.83
(173.5)
6.83
(173.5)
6.83
(173.5)
9.19
(233.5)
9.19
(233.5)
9.19
(233.5)
13.66
(347)
13.66
(347)
13.66
(347)
(140)
5.5
(140)
5.5
(140)
N1
2.34
(59.5)
18.38
(467)
18.38
(467)
18.38
(467)
6.88
2.34
(175)
(59.5)
6.88
2.34
(175)
(59.5)
6.88
2.34
(175)
(59.5)
2.36
60
Connection
AA
Z
12.6
1.85
(320)
(47)
N2
1.10
(28)
1.10
(28)
1.10
(28)
1.10
(28)
13
(330)
13
(330)
13
(330)
3.76
95.5
90
13.78
350
0.78
20
0.78
20
0.55
14
2.87
73
1.46
37
4 0.27
47
12-34
7.48
190
61
H4X-08__
1.85
(47)
0.40
10.2
2.4
3.07
78
1.85
(47)
3.15
80
8.27
210
H4X-07__
1.85
(47)
Terminal lugs
90
3.07
78
N
6.88
(175)
Handle type
M 4p.
13.19
(335)
DIR-04
3.35
85
0.55
14
2.36
60
1007July 2015
Eaton.com/bussmannseries
0.64
16.2
Switch
rating
(A)
600
Part
number
TSH6-3TB
TSH6-4TB
TSH7-3TB
TSH7-4TB
1.49
38
Accessories
and
Terminal shrouds* - includes terminal shroud for Lineside or loadside
600 to 1200A
LUG5-__, LUG6-__
Disconnect switches
12
Features
Agency information
Finger-safe
Fuse blocks
Data Sheet #
Modular knifeblade fuse blocks 100-600A
3192
Class J power distribution fuse blocks 100-400A
10192
Fuses holders
CH Class CC, midget and 10x38 0-30A
3185
Finger-safe Optima holders 0-30A
1102
Optima protection modules 0-30A
1109
CH Class J 0-60A
2144
Online resources
RD16-3-508
Part number
RD16-3-508
RD25-3-508
Thermal current Ith at 40C (A)
16
25
Rated insulation voltage Ui (V)
800
800
Rated impulse withstand voltage Uimp (kV)
8
8
Rated operation currents Ie (A)
(1)
Load duty category Rated voltage
A/B
A/B (1)
500Vac
AC-22 A/AC-22 B
16/16
25/25
500Vac
AC-23 A/AC-23 B
16/16
25/25
690Vac
AC-21 A/AC-21 B
16/16
25/25
690Vac
AC-22 A/AC-22 B
16/16
25/25
690Vac
AC-23 A/AC-23 B
16/16
25/25
Operational power in AC-23 (kW)
(1)(2)
400Vac without prebreak AC
7.5
11
7.5
11
500Vac without prebreak AC (1)(2)
690Vac without prebreak AC (1)(2)
7.5
15
Overload capacity (Ue 415 Vac)
Rated short-time withstand current 0.3 s. ICW (kA rms) (3)
2.5
2.5
Rated short-time making capacity Icm (kA peak) (3)
6
6
Fuse protected short-circuit withstand (kA rms prospective)
(3)
Prospective short-circuit current (kA rms)
50
50
Associated fuse rating (A) (3)
16
25
Connection
Minimum Cu cable cross section (mm2)
1.5
1.5
Maximum Cu cable section (mm2)
16
16
Tightening torque min/max (Nm)
2/2.2
2/2.2
(1) A/B: Category with index A = frequent operation; category with index B = infrequent operation.
(2) The power value is given for information only; the current values vary from one manufacturer to another.
(3) For a rated operating voltage, Ue = 400Vac.
RD40-3-508
40
800
8
RD63-3-508
63
800
8
RD80-3-508
80
800
8
A/B (1)
40/40
25/25
40/40
32/40
25/25
A/B (1)
63/63
63/63
63/63
40/63
40/40
A/B (1)
80/80
63/63
80/80
63/80
40/40
18.5
15
18.5
30
30
30
37
37
37
2.5
6
3
9
3
9
50
40
50
63
50
80
1.5
16
2/2.2
2.5
35
3.5/3.85
2.5
35
3.5/3.85
1007July 2015
Eaton.com/bussmannseries
12-35
Disconnect
switches
Disconnect switches
12
UL electrical specifications
Part number
UL standard
Max ampacity
Handle operation
UL electrical ratings
Max voltage (AC)
Maximum horsepower ratings
3-phase, 208Vac
3-phase, 240Vac
3-phase, 480Vac
3-phase, 600Vac
Electrical characteristics
SCCR with fuse
Recommended upstream
Fuse class
Max. fuse rating
Terminals
Wire type
Wire range and torque - Lb-In (Nm)
Solid
Single
Dual
Stranded
Single
Dual
Mechanical characteristics
Endurances/cycles
Physical characteristics
Dimensions - see drawings on product pages
Weight - Lb (KG)
Environmental
Operating temperature
Flammability rating
Accessories
Handles
Direct
Short selector/NEMA 1, 3R, 4, 4X, 12
Long selector/NEMA 1, 3R, 4, 4X, 12
Pistol handle/NEMA 1, 3R, 4, 4X, 12
Metallic hasp (HD) pistol handle/NEMA 1, 3R, 4, 4X, 12
Selector handle shafts - 5x5mm
5.9/150mm
7.9/200mm
12.6/320mm
Pistol handle shafts - 5x5mm
7.9/200mm
12.6/320mm
15.75/400mm
Selector handle shaft guide
Pistol handle shaft guide
Door mount kit
Shrouds/switch amps
1-Pole
3-pole (loadside and lineside)
Switched 4th pole/switch amps
Ground module (conforms to IEC 60947-3)
Neutral module (conforms to IEC 60947-3)
Auxiliary contacts
NO + NC (1 ea.)
(2) NO
AC ratings
Volts
Amps
6-/8-pole conversion kit
Gangs two switches of same rating, 16-80A switch amps
Not available.
12-36
RD16-3-508
UL 508
16A
Front/Side
RD16-3-508
RD25-3-508
UL 508
25A
Front/Side
RD40-3-508
UL 508
40A
Front/Side
RD63-3-508
UL 508
63A
Front/Side
RD80-3-508
UL 508
80A
Front/Side
600Vac
600Vac
600Vac
600Vac
600Vac
3
5
10
10
7.5
7.5
15
20
7.5
7.5
20
25
15
20
40
40
15
20
40
40
65kA
65kA
10/65kA
50/65kA
50/65kA
J
30A
Integral
75C Cu
J
30A
Integral
75C Cu
J
60/30A
Integral
75C Cu
J
100/60A
Integral
75C Cu
J
100/60A
Integral
75C Cu
#14-10
26.5 (3)
#12
26.5 (3)
#14-10
26.5 (3)
#12
26.5 (3)
#14-10
26.5 (3)
#12
26.5 (3)
#14-10
31.1 (3.5)
#12
31.1 (3.5)
#14-10
31.1 (3.5)
#12
31.1 (3.5)
#14-4
26.5 (3)
#14-12
26.5 (3)
#14-4
26.5 (3)
#14-12
26.5 (3)
#14-4
26.5 (3)
#14-12
26.5 (3)
#14-1
31.1 (3.5)
#10-6
31.1 (3.5)
#14-1
31.1 (3.5)
#10-6
31.1 (3.5)
10,000
10,000
10,000
10,000
10,000
0.5 (0.2)
0.5 (0.2)
0.5 (0.2)
0.7 (0.32)
0.7 (0.32)
-20C to 70C
UL 94-V0
-20C to 70C
UL 94-V0
-20C to 70C
UL 94-V0
-20C to 70C
UL 94-V0
-20C to 70C
UL 94-V0
DIR-01
H4X-01B
H4X-01R
H4X-02B
H4X-02R
H4X-03B
H4X-03R
H4X-03BHD
H4X-03RHD
DIR-01
H4X-01B
H4X-01R
H4X-02B
H4X-02R
H4X-03B
H4X-03R
H4X-03BHD
H4X-03RHD
DIR-01
H4X-01B
H4X-01R
H4X-02B
H4X-02R
H4X-03B
H4X-03R
H4X-03BHD
H4X-03RHD
DIR-01
H4X-01B
H4X-01R
H4X-02B
H4X-02R
H4X-03B
H4X-03R
H4X-03BHD
H4X-03RHD
DIR-01
H4X-01B
H4X-01R
H4X-02B
H4X-02R
H4X-03B
H4X-03R
H4X-03BHD
H4X-03RHD
SH4-150
SH4-200
SH4-320
SH4-150
SH4-200
SH4-320
SH4-150
SH4-200
SH4-320
SH4-150
SH4-200
SH4-320
SH4-150
SH4-200
SH4-320
SH3-200
SH3-320
SH3-400
SH-GUIDE1
SH-GUIDE2
DOOR-508
SH3-200
SH3-320
SH3-400
SH-GUIDE1
SH-GUIDE2
DOOR-508
SH3-200
SH3-320
SH3-400
SH-GUIDE1
SH-GUIDE2
DOOR-508
SH3-200
SH3-320
SH3-400
SH-GUIDE1
SH-GUIDE2
DOOR-508
SH3-200
SH3-320
SH3-400
SH-GUIDE1
SH-GUIDE2
DOOR-508
TSH1-1TB
TSH1-3TB
POLE-16
GND-16-40
NTRL-16-40
TSH1-1TB
TSH1-3TB
POLE-25
GND-16-40
NTRL-16-40
TSH1-1TB
TSH1-3TB
POLE-40
GND-16-40
NTRL-16-40
TSH2-3TB
GND-63-80
NTRL-63-80
TSH2-3TB
GND-63-80
NTRL-63-80
BAC01
BAC02
BAC01
BAC02
BAC01
BAC02
BAC01
BAC02
BAC01
BAC02
240Vac
10A
240Vac
10A
240Vac
10A
240Vac
10A
240Vac
10A
KIT-6POLE
KIT-6POLE
KIT-6POLE
KIT-6POLE
KIT-6POLE
1007July 2015
Eaton.com/bussmannseries
Disconnect switches
12
Switch
Switch
amp
rating
No. of
poles
SCCR
@600V
Max
Class J
fuse
16
65kA
30A
10
10
25
65kA
30A
7.5
7.5
15
20
40
10kA
65kA
60A
30A
7.5
7.5
20
25
63
50kA
65kA
100A
60A
15
20
40
40
80
50kA
65kA
100A
60A
15
20
40
40
Wire type
75C Cu
RD16-3-508
75C Cu
RD25-3-508
75C Cu
RD40-3-508
75C Cu
RD63-3-508
75C Cu
RD80-3-508
For switch
part number
All switches
Color
Black
Test
function
N
Padlockable
Y - On Switch
Part
number
DIR-01
Test
function
N
N
N
N
Padlockable
Y
Y
Y
Y
Part
number
H4X-01B(1)
H4X-01R(1)
H4X-02B(2)
H4X-02R(2)
or
External front or right side operated selector handles - shaft required
(1)
or
(2)
NEMA
type
1, 3R, 4,
1, 3R, 4,
1, 3R, 4,
1, 3R, 4,
4X,
4X,
4X,
4X,
12
12
12
12
Color
Black
Red/yellow
Black
Red/yellow
Handle
length
Short
Short
Long
Long
Part
number
Color
Black
Red/yellow
Handle
length
Test
function
N
N
Padlockable
Y
Y
Defeatable
Y
Y
Part
number
H4X-03B
H4X-03R
NEMA
type
1, 3R, 4, 4X, 12
1, 3R, 4, 4X, 12
Color
Black
Red/yellow
Handle
length
Test
function
N
N
Padlockable
Y
Y
Defeatable
Y
Y
Part
number
H4X-03BHD
H4X-03RHD
Disconnect
switches
Wire size
#14-#10 Sol
Dual #12 Sol
#14-#4 Str
Dual #14-#12 Str
#14-#10 Sol
Dual #12 Sol
#14-#4 Str
Dual #14-#12 Str
#14-#10 Sol
Dual #12 Sol
#14-#4 Str
Dual #14-#12 Str
#14-#10 Sol
Dual #12 Sol
#14-#1 Str
Dual #10-#6 Str
#14-#10 Sol
Dual #12 Sol
#14-#1 Str
Dual #10-#6 Str
Metallic hasp (heavy duty) external front operated pistol handles - shaft required
Handle
+
(1)
(2)
+
+
Mounting depth
(X) in (mm)
3.50~7.60 (89~193)
3.50~9.50 (89~241)
3.50~14.9 (89~378)
Length
in (mm)
7.9 (200)
12.6 (320)
15.7 (400)
Mounting depth
(X) in (mm)
3.30~7.40 (84~188)
3.30~9.30 (84~236)
3.30~14.7 (84~373)
Part
number
SH4-150(1)
SH4-200(1)
SH4-320(1)
Part
number
SH3-200(2)
SH3-320(2)
SH3-400(2)
Required for 12.6 (320mm) long shafts, optional for other lengths
Required for 15.7 (400mm) long shafts, optional for other lengths
Part
number
SH-GUIDE1
SH-GUIDE2
Door mount kit - for mounting switch on the right side of the enclosure or directly on the enclosure door
using switch side operation shaft location. Kit includes a shaft. Order switch and selector handle separately.
Switch
rating
All switches - kit includes shaft
Part
Number
DOOR-508
1007July 2015
Eaton.com/bussmannseries
12-37
Disconnect switches
12
Aux contacts
Contact
type
NO + NC
NO
Shrouds
Auxillary contacts
Switch amp
rating
16-40A
16-40A
63-80A
Number of
contacts
1 Ea
2
Continuous
amp rating
10A
10A
Voltage
rating
240Vac
240Vac
and
Max number of
units per switch
2 (1 per side/4 contacts total)
2 (1 per side/4 contacts total)
Part
number
BAC01
BAC02
Terminal shrouds - includes terminal shroud for both lineside and loadside
Number
of poles
1 (For switched 4th pole)
3
3
Location on
switch
Lineside and loadside
Lineside and loadside
Lineside and loadside
Part
number
TSH1-1TB
TSH1-3TB
TSH2-3TB
and
Accessories
Switch amp
rating
16
25
40
th
Part
number
POLE-16
POLE-25
POLE-40
and
Gnd-neut modules
Ground and Neutral Modules - provides unswitched ground or neutral pole - conforms to IEC 60947-3
Switch Amp
Rating
16-40
63-80
16-40
63-80
Module
Type
Ground
Ground
Neutral
Neutral
Part
Number
GND-16-40
GND-63-80
NTRL-16-40
NTRL-63-80
and
6-pole conversion kit - creates a 6-pole switch by ganging two 3-pole switches of equal rating
N or G
N or G
2.95
75
2.52
64
2
F
M
1.42
36
3.19
81
2.52
64
1.99
50.6
0.24
6
0.35
8.8
F1
M5
F1
0.35
8.8
0.23
6
1.96
50
1. Position for 1 switched 4th pole (1 per device max.), or ground or neutral module (2 per device max.) or 1 auxiliary contact.
2. Position for 1 auxiliary contact only.
Note: Maximum of 4 Auxiliary contacts, or 3 Auxiliary contacts + one ground or neutral module, or one switched 4th pole.
Switch
rating (A)
16 to 40
63 to 80
12-38
Overall
dimensions
D min
1.18
(30)
1.18
(30)
D max
9.25
(235)
9.25
(235)
E min
3.94
(100)
3.93
(100)
E max
14.64
(372)
14.64
(372)
N
AC
G
2.68
68
1.97
50
1.42
36
N
AC
G
2.67
68
Terminal
shroud
AC
4.33
(110)
4.33
(110)
Switch
body
F
1.77
(45)
2.06
(52.5)
1007July 2015
F1
0.59
(15)
0.69
(17.5)
G
2.67
(68)
2.99
(76)
J
0.59
(15)
0.69
(17.5)
Eaton.com/bussmannseries
0.35
8.8
F1
F1
T
0.35
8.8
M5
Switch
mounting
M
N
1.18
2.95
(30)
(75)
1.38
3.35
(35)
(85)
Connection
T
0.59
(15)
0.69
(17.5)
2.79
71
Dimensions in (mm)
N or G
Auxiliary contact
configurations
N or G
* Kit ships with a direct handle. If external handle is needed order a selector handle and shaft for the UL 508 Rotary Disconnect Switches.
Note: To create an 8-pole switch from 16 to 40 amp switches, use two 3-pole switches of equal ratings plus two switched 4th poles (part # POLE-_).
N or G
Part
number
KIT-6POLE*
N or G
6-pole kit
Switch amp
rating
All switches
Disconnect switches
12
1.77
45
0.35 F1
T T
8.8
2.06
52.5
0.29
7.5
F1 0.35
8.8
0.24
6
1.69
43
2.06
52.5
1.42
36
2.79
71
2.06
52.5
J
F2
X M
N
G
2.67
68
3.50
89
3.07
78
N
G
2.67
68
J
F2
X M
0.35 F1
T T
8.8
2.06
52.5
1.36
34.7
0.29
7.5
F1 0.35
8.8
1. Position for 1 switched 4th pole (1 per device max.) or 1 auxiliary contact.
2. Position for 1 auxiliary contact only.
Note: Maximum of 4 auxiliary contacts, or 3 auxiliary contacts + one switched 4th pole.
Overall
Switch
Switch
dimensions
body
mounting
Connection
E min
E max
F
F1
F2
G
J
M
N
T
X
4.13 (105) 14.64 (372) 3.83 (97.5) 0.59 (15) 1.77 (45) 2.67 (68) 1.92 (48.75) 1.18 (30) 2.95 (75) 0.59 (15)
0.29 (7.5)
4.13 (105) 14.65 (372) 4.13 (105) 0.69 (17.5) 2.06 (52.5) 2.99 (76) 2.06 (52.5) 1.38 (3.5) 3.35 (85) 0.69 (17.5) 0.34 (8.75)
3.07
78
Direction of
front operation
1.42
36
3.46
88
Selector
H4X-02_
90
3.07
78
90
1.22
31
0.11
3
4 0.27
47
Direction of
right side operation
0.53
13.5
Selector
H4X-01_
1.10
28
2.79
71
1.57
40
0.88
22.5
1.45
37
1.57
40
Pistol
H4X-03_
1.10
28
4 0.27
47
H4X-03_ With 4 mounting screws
1007July 2015
Eaton.com/bussmannseries
12-39
Disconnect
switches
Switch
rating (A)
16 to 40
63 to 80
Disconnect switches
12
Description
Features
NEMA 1, 3R, 4
and 12
NEMA 4X
stainless steel
Ratings:
NEMA 4X
polycarbonate
or fiberglass
Volts: 600Vac
250-600Vdc*
Amps: 16-1200A
Short-circuit current ratings:
UL 98: 25kA-200kA
UL 508: 10kA-65kA
Specifications
Agency information
CE compliant
Class
CC
CC
CC
J
J
J
J
J
L
L
L
Auxiliary contacts
Terminal shrouds
Online resources
12-40
1007July 2015
Type
LP-CC time-delay, current limiting
FNQ-R time-delay
KTK-R fast-acting
LPJ time-delay, current limiting
JKS fast-acting fuses
DFJ high speed drive fuse
KRP-C time-delay, current limiting
KTU fast-acting
KLU time-delay
Eaton.com/bussmannseries
Data Sheet #
1023
1014
1015
1006 (0-60A)
1007 (70-600A)
1026 (0-60A)
1027 (70-600A)
1048 (0-600A)
1008
1010
1013
Disconnect switches
UL 98 enclosed fused disconnects30 to 800A
3-pole UL 98 600Vac
4X - 60
12
30-800A
ER
NEMA rating
Amp rating
30, 60, 100, 200, 400, 600, 800
Fuse class
J = Class J, L = Class L
NEMA 4X plastic
NEMA 4X stainless
Number of poles
3 = 3-pole
Handle type
P = Pistol
Handle color
B = Black, R = Red
UL general
purpose
amp rating
30
60
100
200
400
600
800
Fuse
type
J
J
J
J
J
J
L
All part numbers provided with integral or installed lugs and a black selector handle.
Order Red/yellow handle by changing the suffix B to R.
Disconnect
switches
Part numbers -
1
ER1-30J3PB
ER1-60J3PB
ER1-100J3PB
ER1-200J3PB
ER1-400J3PB
ER1-600J3PB
ER1-800L3PB
3R
ER3R-30J3PB
ER3R-60J3PB
ER3R-100J3PB
ER3R-200J3PB
ER3R-400J3PB
ER3R-600J3PB
ER3R-800L3PB
4
ER4-30J3PB
ER4-60J3PB
ER4-100J3PB
ER4-200J3PB
ER4-400J3PB
ER4-600J3PB
ER4-800L3PB
4X plastic(1)
ER4P-30J3PB
ER4P-60J3PB
ER4P-100J3PB
ER4P-200J3PB
ER4P-400J3PB
ER4P-600J3PB
ER4P-800L3PB
4X stainless
ER4X-30J3PB
ER4X-60J3PB
ER4X-100J3PB
ER4X-200J3PB
ER4X-400J3PB
ER4X-600J3PB
ER4X-800L3PB
12
ER12-30J3PB
ER12-60J3PB
ER12-100J3PB
ER12-200J3PB
ER12-400J3PB
ER12-600J3PB
ER12-800L3PB
(1) Enclosures 100A are polycarbonate, flammability rating UL 94-5VA-V0, 200A are fiberglass, flammability rating UL 94-5V.
Switch ratings - for wire types, ranges and tightening torques, see table on page 12-9
Switch
amp Rating
30
60
100
200
400
600
800
Disconnect
switch
RDF30J-3
RDF60J-3
RDF100J-3
RDF200J-3
RDF400J-3
RDF600J-3
RDF800L-3
Fuse
type
J
J
J
J
J
J
L
No. of
poles
Voltage
Vac Vdc
SCCR
@ Vac
250
3
600
N/A
250
600
200kA
Max Hp rating
@ 600Vac
20
50
75
150
350
500
1007July 2015
Eaton.com/bussmannseries
12-41
Disconnect switches
12
MH H
H MH
MW
MH H
MW
MW
Part
number family
Amp
rating
Fuse
type
ER_-30J
30
ER_-60J
60
ER_-100J
100
ER_-200J
200
ER_-400J
400
ER_-600J
600
ER_-800L
800
NEMA
enclosure type
1, 3R, 4, 12
4X-SST
4X-plastic(1)
1, 3R, 4, 12
4X-SST
4X-plastic(1)
1, 3R, 4, 12
4X-SST
4X-plastic(1)
1, 3R, 4, 12
4X-SST
4X-plastic(1)
1, 3R, 4, 12
4X-SST
4X-plastic(1)
1, 3R, 4, 12
4X-SST
4X-plastic(1)
1, 3R, 4, 12
4X-SST
4X-plastic(1)
HxWxD
10x10x6
10x10x6
12x10x6
12x10x6
12x10x6
13x13x6
14x12x6
14x12x6
13x13x6
24x20x8
24x20x8
27x21x10
48x36x12
48x36x12
51x37x14
48x36x12
48x36x12
51x37x14
48x36x12
48x36x12
51x37x14
Mounting centers h x w
A
B
C
8.3x8.3
10.7x8.3
8.3x10.7
12x5.6
7.6x10
10.3x8.3
12.7x8.3
8.3x10.7
14x7.6
9.6x12
12.3x10.3
14.7x10.3
12.3x12.7
14x7.6
9.6x12
22.3x18.3
24.7x18.3
22.3x20.7
25.75x14
46.3x34.3
48.7x34.3
46.3x36.7
50x28.5
46.3x34.3
48.7x34.3
46.3x36.7
50x28.5
46.3x34.3
48.7x34.3
46.3x36.7
50x28.5
Weight
lbs
15
15
8
19
19
11
21
21
12
55
55
39
188
188
186
216
216
214
216
216
214
(1) Enclosures 100A are polycarbonate, flammability rating UL 94-5VA-V0, 200A are fiberglass, flammability rating UL 94-5V.
Contact
type
NO
NC
Number of
contacts
1
1
Continuous
amp rating
10A
10A
Voltage
rating
600Vac
600Vac
Part
number
BAC05
BAC06
Terminal shrouds - for 200 to 800 amp switches - includes terminal shroud for lineside or loadside
Switch
amp rating
200
400
600-800
12-42
Number
of poles
3
3
3
Part
number
TSH8-3TB
TSH9-3TB
TSH10-3TB
1007July 2015
Eaton.com/bussmannseries
Disconnect switches
UL 98 enclosed non-fused disconnects30 to 1200A
3-pole UL 98 600Vac
4X - 60
12
30-100A
ER
NEMA rating
Amp rating
30, 60, 100, 200, 400, 600, 800, 1200
N = Non-fused
Number of poles
200-1200A
3 = 3-pole
Handle type
NEMA 4X
NEMA 4X stainless
NEMA 4X
NEMA 4X stainless
P = Pistol
Handle color
B = Black, R = Red
All Part numbers provided with integral or installed lugs and a black selector handle.
Order Red/yellow handle by changing the suffix B to R.
NEMA enclosure type and part number
1
ER1-30N3PB
ER1-60N3PB
ER1-100N3PB
ER1-200N3PB
ER1-400N3PB
ER1-600N3PB
ER1-800N3PB
ER1-1200N3PB
3R
ER3R-30N3PB
ER3R-60N3PB
ER3R-100N3PB
ER3R-200N3PB
ER3R-400N3PB
ER3R-600N3PB
ER3R-800N3PB
ER3R-1200N3PB
4
ER4-30N3PB
ER4-60N3PB
ER4-100N3PB
ER4-200N3PB
ER4-400N3PB
ER4-600N3PB
ER4-800N3PB
ER4-1200N3PB
4X plastic(1)
ER4P-30N3PB
ER4P-60N3PB
ER4P-100N3PB
ER4P-200N3PB
ER4P-400N3PB
ER4P-600N3PB
ER4P-800N3PB
N/A
4X stainless
ER4X-30N3PB
ER4X-60N3PB
ER4X-100N3PB
ER4X-200N3PB
ER4X-400N3PB
ER4X-600N3PB
ER4X-800N3PB
ER4X-1200N3PB
12
ER12-30N3PB
ER12-60N3PB
ER12-100N3PB
ER12-200N3PB
ER12-400N3PB
ER12-600N3PB
ER12-800N3PB
ER12-1200N3PB
(1) Enclosures 100A are polycarbonate, flammability rating UL 94-5VA-V0, 200A are fiberglass, flammability rating UL 94-5V.
Switch ratings - for wire types, ranges and tightening torques, see table on page 12-27
Switch
amp rating
30
60
100
200
400
600
800
1200
Disconnect
switch
RD30-3
RD60-3
RD100-3
RD200-3
RD400-3
RD600-3
RD800-3
RD1200-3
No. of
poles
Volts AC
SCCR
100kA
25kA/100kA*
600
Max Hp rating
@ 600Vac
25
50
200
200kA
100kA
350
500
1007July 2015
Eaton.com/bussmannseries
12-43
Disconnect
switches
Disconnect switches
12
MH H
H MH
MW
MH H
MW
MW
Part
number family
Amp
rating
ER_-30
30
ER_-60
60
ER_-100
100
ER_-200
200
ER_-400
400
ER_-600
600
ER_-800
800
ER_-1200
(1)
1200
NEMA
enclosure type
1, 3R, 4, 12
4X-SST
4X-plastic(1)
1, 3R, 4, 12
4X-SST
4X-plastic(1)
1, 3R, 4, 12
4X-SST
4X-plastic(1)
1, 3R, 4, 12
4X-SST
4X-plastic(1)
1, 3R, 4, 12
4X-SST
4X-plastic(1)
1, 3R, 4, 12
4X-SST
4X-plastic(1)
1, 3R, 4, 12
4X-SST
4X-plastic(1)
1, 3R, 4, 12
4X-SST
Mounting centers
A
B
8.3x6.3
10.7x6.3
10x3.6
8.3x6.3
10.7x6.3
10x3.6
10.3x8.3
12.7x8.3
14x7.6
18.3x14.3
20.7x14.3
21.5x10.1
34.3x28.3
36.7x28.3
38x28.9
46.3x34.3
48.7x34.3
50x28.5
46.3x34.3
48.7x34.3
50x28.5
58.3x34.3
60.7x34.3
HxWxD
10x8x6
10x8x6
9x9x6
10x8x6
10x8x6
9x9x6
12x10x6
12x10x6
13x13x6
20x16x8
20x16x8
20x17x12
36x30x8
36x30x8
37x32x14
48x36x12
48x36x12
51x37x 14
48x36x12
48x36x12
51x37x 14
60x36x16
60x36x16
hxw
C
8.3x8.7
5.6x8
8.3x8.7
5.6x8
8.3x10.7
9.6x12
18.3x16.7
34.3x30.7
46.3x36.7
46.3x36.7
58.3x36.7
Weight
lbs
11
11
5
12
12
5
12
12
8
39
39
31
122
122
103
209
209
187
211
211
189
268
268
Enclosures 100A are polycarbonate, flammability rating UL 94-5VA-V0, 200A are fiberglass, flammability rating UL 94-5V.
Switch
amp rating
30-100
30-100
100-1200
100-1200
100-1200
100-1200
Contact
type
NO + NC
NO
NO + NC
NO + NC
NO + NC
NO + NC
Number of
contacts
1 of each
2
1 of each
1 of each
1 of each
1 of each
Continuous
amp rating
10A
10A
10.1A
10.1A
1A
1A
Voltage
rating
240Vac
240Vac
125-250Vac
125-250Vac
125Vac
125Vac
Part
number
BAC01*
BAC02*
BAC03**
BAC04**
BAC11**
BAC12**
Switch
amp rating
30-100
200A
200A
400A
400A
600A
800-1200A
12-44
Number
of poles
3
3
3
3
3
3
3
Location
on switch
Lineside and loadside
Lineside
Loadside
Lineside
Loadside
Lineside or loadside
Lineside or loadside
1007July 2015
Eaton.com/bussmannseries
Part
number
TSH3-3TB
TSH4-3T
TSH4-3B
TSH5-3T
TSH5-3B
TSH6-3TB
TSH7-3TB
Disconnect switches
12
4X - 63
16-80A
ER
NEMA rating
Amp rating
16, 25, 40, 63, 80
N = Non-fused
Number of poles
NEMA 4X plastic
NEMA 4X stainless
3 = 3-pole, 6 = 6-Pole
Handle type
S = Selector*, P = Pistol**
Handle color
B = Black, R = Red
* 6-Pole switches only, selector handle does not interlock the enclosure door.
** 3-pole switches only.
Part numbers
No. of
poles
3
6
3
6
3
6
3
6
3
6
16
25
40
63
80
1
ER1-16N3PB
ER1-16N6SB
ER1-25N3PB
ER1-25N6SB
ER1-40N3PB
ER1-40N6SB
ER1-63N3PB
ER1-63N6SB
ER1-80N3PB
ER1-80N6SB
3R
ER3R-16N3PB
ER3R-16N6SB
ER3R-25N3PB
ER3R-25N6SB
ER3R-40N3PB
ER3R-40N6SB
ER3R-63N3PB
ER3R-63N6SB
ER3R-80N3PB
ER3R-80N6SB
4
ER4-16N3PB
ER4-16N6SB
ER4-25N3PB
ER4-25N6SB
ER4-40N3PB
ER4-40N6SB
ER4-63N3PB
ER4-63N6SB
ER4-80N3PB
ER4-80N6SB
4X plastic(1)
ER4P-16N3PB
ER4P-16N6SB
ER4P-25N3PB
ER4P-25N6SB
ER4P-40N3PB
ER4P-40N6SB
ER4P-63N3PB
ER4P-63N6SB
ER4P-80N3PB
ER4P-80N6SB
4X stainless
ER4X-16N3PB
ER4X-16N6SB
ER4X-25N3PB
ER4X-25N6SB
ER4X-40N3PB
ER4X-40N6SB
ER4X-63N3PB
ER4X-63N6SB
ER4X-80N3PB
ER4X-80N6SB
Disconnect
switches
UL general
purpose
amp rating
- All Part numbers provided with a black selector handle. Order red/yellow handle by changing the suffix B to R.
12
ER12-16N3PB
ER12-16N6SB
ER12-25N3PB
ER12-25N6SB
ER12-40N3PB
ER12-40N6SB
ER12-63N3PB
ER12-63N6SB
ER12-80N3PB
ER12-80N6SB
Switch ratings - for wire types, ranges and tightening torques, see table on page 12-35
Switch
amp
rating
16
25
40
63
80
Disconnect
switch
RD16-3-508
RD25-3-508
RD40-3-508
RD63-3-508
RD80-3-508
Voltage
Vac
Vdc
600
N/A
SCCR with
max upstream
Class J fuse
65kA / 30A
65kA / 30A
65kA / 30A 10kA / 60A
65kA / 60A 50kA / 100A
65kA / 60A 50kA / 100A
1, 3R, 4, 12
4X-SST
4X-plastic(1)
3
6
(1) Polycarbonate.
Switch amp
ratings
16-80A
16-80A
16-80A
16-80A
16-63A
80A
16-80A
HxWxD
8x6x6
10x8x6
8x6x6
10x8x6
7.4x8.7x5.8
9.4x8.7x5.9
11.4x10.7x6.3
A
Mounting centers h x w
A
B
C
6.3x4.3
8.3x6.3 W
8.7x4.3
6.3x6.7
10.7x6.3
8.3x8.7
8x3.6
H
MH 3.6x8
A10x3.6
5.6x8
12x5.6
7.6x10
MH H
Weight
lbs
8
W
11
8
11
4
B5
6
H MH
MW
H MH
MH H
MW
MW
1007July 2015
C
MW
MW
MW
B
MW
MH H
MW
Note: Voltage, SCCR and horsepower ratings are the same for 3- and 6-pole UL 508 non-fused disconnect switches.
NEMA
enclosure type
Max Hp
rating
@ 600Vac
10
20
25
40
40
Eaton.com/bussmannseries
12-45
12
Disconnect switches
UL 508 enclosed non-fused disconnect16 to 80A
Contact
type
Number of
contacts
Continuous
amp rating
Voltage
rating
Max number of
units per switch
Part
number
NO + NC
1 Ea
10A
240Vac
BAC01
10A
240Vac
BAC02
NO
Terminal shrouds - includes terminal shroud for both lineside and loadside
Switch
amp rating
Number
of poles
Location on
switch
16-40A
TSH1-3TB
63-80A
TSH2-3TB
Switch amp
rating
16
25
40
Part
number
Part
number
POLE-16
POLE-25
POLE-40
15149
Specifications
Description: Fused, dead front disconnect switches
Ratings:
Volts: 600Vac
Amps: 30A
SCCR: 200kA RMS Sym.
Dielectric voltage: 2200V
Motor rating: 5Hp
Poles: 2 to 3
Agency information: UL Recognized, file E120756 for
General Industrial installations. Guide WGEU2. CSA
certified, file LR37129-6. Examined under the new proposed
standard UL 1429 which imparts a stricter set of test
conditions than the former program that combined the
applicable portions for UL 512 (fuse holders) and UL 98
(enclosed switches).
12-46
1007July 2015
Eaton.com/bussmannseries
13
Contents
Description
TM
Page
1007July 2015
Eaton.com/bussmannseries
13-1
Telecom
protection products
13
TPC and
TPCDS
Specifications
Descriptions:
TPC: Telepower
compact currentlimiting fuses.
TPCDS:
Telepower compact
fused disconnect
switch available in two disconnect switch profiles in addition
to a variety of terminal styles. Recommended 0.75 centerto-center product spacing.
Dimensions: See Data Sheet 5023.
Ratings:
Volts: 80Vdc
Amps: 3-125A (see catalog numbers table for details)
IR: 100kA
Agency information: CE, UL Recognized (investigated to
UL 1801) as a disconnect switch for the interruption of load
current by means of withdrawing the fuse pullout.
Recognized to US and Canadian requirements under the
component recognition program of Underwriters Laboratories
Inc. Files E219046 and E56412.
Flammability ratings: Fuse UL 94V0, 170C RTI, Housing
UL 94V0, 120C RTI.
Typical applications
Telecommunications DC power circuit protection
Replacement of DC telecom circuit breakers
Applications where venting of arc or molten metals and
gases during opening would pose a problem to surrounding
devices
Catalog numbers
TPCS disconnect
Catalog
numbers
TPCDS-BBE-1
TPCDS-BBE-2
TPCDS-BBE-3
TPCDS-BBM-1
TPCDS-BBM-2
TPCDS-BBM-3
TPCDS-BSE-1
TPCDS-BSE-2
TPCDS-BSE-3
TPCDS-BSM-1
TPCDS-BSM-2
TPCDS-BSM-3
TPCDS-SSE-1
TPCDS-SSE-2
TPCDS-SSE-3
TPCDS-SSM-1
TPCDS-SSM-2
TPCDS-SSM-3
TPCDS-D-BC1*
TPCDS-D-BC2*
TPCDS-D-CC1*
TPCDS-D-SEC1*
TPCDS-D-SEC2*
TPCDS-D-SMC1*
TPCDS-D-SMC2*
switch
Amp
range
3-125
3-125
3-125
3-125
3-125
3-125
3-125
3-125
3-125
3-125
3-125
3-125
3-125
3-125
3-125
3-125
3-125
3-125
3-125
3-125
3-125
3-125
3-125
3-125
3-125
TPCDS -
TPCDS - D -
1007July 2015
Eaton.com/bussmannseries
13
TPM and
TPMDS
Catalog numbers
Typical applications
Telecommunications DC power circuit protection
Applications with restricted space, or mounting in 1 U panels
Description
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
Disconnect, English hardware
Disconnect, metric hardware
Amp
rating
3
4
5
6
7
8
10
12
15
20
25
30
3-30
3-30
Telecom
protection products
Specifications
Description:
TPM:
Telepower
miniature currentlimiting fuses.
TPMDS:
Telepower
miniature fused
disconnect switch.
Dimensions: See Data Sheet 5022.
Ratings:
Volts: 80Vdc
Amps: 3-30A
IR: 20kA
Agency information: CE, UL Recognized (investigated to
UL 1801) as a disconnect switch for the interruption of load
current by means of withdrawing the fuse pullout.
Recognized to US and Canadian requirements under the
component recognition program of Underwriters Laboratories
Inc. Files E219046 and E56412.
Flammability ratings: Fuse UL 94V0, 170C RTI; Switch UL
94V0, 140C RTI.
Catalog
numbers
TPM-3
TPM-4
TPM-5
TPM-6
TPM-7
TPM-8
TPM-10
TPM-12
TPM-15
TPM-20
TPM-25
TPM-30
TPMDS-E
TPMDS-M
Notes:
1007July 2015
Eaton.com/bussmannseries
13-3
13
TP15900-4
Specifications
Description: 4-pole
disconnect switch for
use with Telepower
fuses Type TPA and
TPA-B.
Dimensions: See dimensions illustrations.
Ratings:
Volts: 145Vdc@40A per pole
80Vdc@50A per pole
Agency information: CE, UL Recognized File E97649 as a
disconnect switch for interruption of load current by means of
withdrawing the fuse carrier. UL Recognized as a
component for telecommunication power distribution
equipment (UL category QPQY2). UL Recognized fuses for
branch circuit protection. CSA Component Acceptance for the
system.
Flammability rating: UL 94V0, 140C.
Typical applications
Telecommunications DC power circuit protection
Catalog
numbers
Catalog numbers
Description
Available fuses
Product
TPA
TPA-B
Ratings (amps)
3, 5, 10, 15, 20,
25, 30, 40, 50
20, 25, 30
Volts (Vdc)
170
65
100kA
Accessories
Spare fuse holders:catalog numbers 5TPH and
TPSFH-AS.
Dimensions - mm (in)
1007July 2015
Eaton.com/bussmannseries
IR
20kA
13
TP15914
Typical applications
Telecommunications DC power circuit protection
Catalog
numbers
TP15914
TP15914-1
Catalog numbers
Specifications
Description: DC power distribution
indicating fuses.
Dimensions: See dimensions illustration.
Ratings:
Volts: 170Vdc TPA
65Vdc TPA-B
Amps: 3-50A TPA
20-30A TPA-B
IR: 100kA TPA
20kA TPA-B
Agency information: CE, UL Recognized, Guide JFHR2,
File E56412, CSA Certified, Class 1422-30, File 53787.
Typical applications
Telecommunications DC power circuit protection
Catalog numbers (amps)
Catalog
numbers
TPA-3
TPA-5
TPA-10
TPA-15
TPA-20
TPA-25
Amp
rating
3
5
10
15
20
25
Catalog
numbers
TPA-30
TPA-40
TPA-50
TPA-B-20
TPA-B-25
TPA-B-30
Amp
rating
30
40
50
20
25
30
Dimensions - mm (in)
Hardware
English
Metric
Dimensions mm - (in)
TOP
0.745
0.284
1.5
0.215
1.5
Accessories
Spare fuse holders: 5 position holder; 5TPH; 6 position
holder; TPSFH-AS
Use with fused disconnect switches TP15900-4, TP15914
0.625
3.57
4.27
76.07
3.0
Accessories
Spare fuse holders:catalog numbers 5TPH and TPSFH-A
1007July 2015
Eaton.com/bussmannseries
13-5
Telecom
protection products
Specifications
Description:
Modular 4-pole
disconnect switch
for TPA fuses
4-poles per module
up to four modules
ganged together.
Features open fuse
indication and fuse presence indication along with fuse
orientation rejection feature.
Dimensions: See dimensions illustrations.
Ratings:
Volts: 145Vdc
Amps: 50A per pole
Agency information: CE, UL Recognized as a disconnect
switch for interruption of load current by means of
withdrawing the fuse carrier. UL Recognized as a component
for telecommunication power distribution equipment (UL
category QPQYZ), UL Recognized fuses for branch circuit
protection, CSA component acceptance for the system. UL
Recognized, Guide JFHR2, File E56412., CSA Certified,
Class 1422-30, File 53787.
Flammability rating: UL 94V0, 150C.
13
TPS
15800
Specifications
Description: DC power
distribution
non-indicating fuses
specifically designed to
meet the unique needs
of DC power distribution systems. For use with Bussmann
series fused disconnect switch 15800.
Dimensions: See dimensions illustration.
Ratings:
Volts: 170Vdc
Amps: 1-70A
IR: 100kA
Agency information: CE, UL Recognized, Guide JFHR2,
File E56412, RoHS compliant.
Specifications
Description: Fused
disconnect switch for
use only with the
following fuses;
Main: Telepower TPS
1 to 70 Amp.
Alarm: Bussmann series
GMT-A only (page 13-13).
Recommend GMT-X Cover
(page 13-13).
Dimensions: See dimensions illustration.
Ratings:
Volts: 60Vdc
Amps: 3-70A
SCCR: 100kA
Agency information: CE, UL Recognized, Guide QPQY2,
File E97649.
Flammability rating: UL 94V0, 150C.
TPS-1
TPS-1L
TPS-2
TPS-2L
TPS-3
TPS-3L
TPS-5
TPS-5L
TPS-6
Catalog numbers
Catalog
numbers
15800-R-200
15800-F-200
Typical applications
Telecommunications DC power circuit protection
Applications requiring printed circuit board mounting
Dimensions - in (mm)
TPS-50V
TPS-60
TPS-60L
TPS-70
TPS-70L
TPS-70LB
LB = Bolt tag
Accessories
Spare fuse holder: TPSFH-AS, see page 15-6.
Accessories
Spare fuse holders:catalog numbers TPSFH-AS (TPS
fuses) and TPSFH-T (GMT fuses).
13-6
TPS-30
TPS-30L
TPS-35
TPS-35L
TPS-40
TPS-40L
TPS-40V
TPS-50
TPS-50L
Dimensions - in (mm)
72 lb-in
TPS-6L
TPS-10
TPS-10L
TPS-15
TPS-15L
TPS-20
TPS-20L
TPS-25
TPS-25L
1007July 2015
Eaton.com/bussmannseries
TP158HC
Specifications
Description: Panel mount, rear
access high amp version of
Bussmann series 15800 fused
disconnect switch for use only with
the following fuses; Main:
Telepower TPL-B 70-250 Amps,
Alarm: Bussmann series GMT-A.
Dimensions: See Data Sheet
5021.
Ratings:
Volts: 80Vdc
Amps: 70-250A
SCCR: 100kA
Agency information: UL Recognized (investigated to UL
1801) as a disconnect switch for the interruption of load
current by means of withdrawing the fuse pullout. Guide
QPQY2, File E97649.
Flammability rating: UL 94V0, 150C.
13
Application notes
The line connection uses a 14-20 bolt (metric M6X1) that
threads into the line terminal. The line terminal is designed
with a float of 0.02 (0.50mm) to allow for variation in the
distance between the TP158HC mounting flange and the
line busbar (see Dimensions). Equipment should be
designed to eliminate any relative movement between the
TP158HC mounting flange and the line busbar.
The alarm circuit is not intended for precharging of
capacitive circuits. Alarm circuit current 1A maximum.
Telecom
protection products
Typical applications:
Telecommunications DC power circuit protection
Catalog
numbers
TP158HC
TP158HC-M
Catalog numbers
Hardware
English
Metric
Accessories
Spare fuse holders:TPSFH-LB(TPL-B fuses) and TPSFH-T
(GMTfuses).
1007July 2015
Eaton.com/bussmannseries
13-7
13
15100
Specifications
Description: Fused
disconnect system for use with
Telepower fuses Type TPL.
Dimensions: See dimensions
illustrations.
Ratings:
Volts: 60Vdc
Amps: 70-800A
SCCR: 100kA
Agency information: CE, UL Recognized, Guide QPQY2,
File E97649.
Typical applications
Telecommunications DC power circuit protection
Catalog
numbers
15100-401
15100-601
Catalog numbers
Dimensions - in (mm)
6.75"
(171.45mm)
(76.2mm)
3"
(101.6mm)
4"
5.75"
(92.07mm)
3.63"
(69.85mm)
2.75"
(181.10mm)
7.13"
(33.33mm)
1.31"
(66.67mm)
2.63"
(133.35mm)
5.25"
1007July 2015
Eaton.com/bussmannseries
13
High-current switch
Catalog
numbers
TPHCS250-P
TPHCS800-P
TPHCS-B-M
TPHCS-B-E
TPHCS-B-ML
TPHCS-B-EL
TPHCS-B-MAV
TPHCS-B-EAV
Description
rating/hardware/option
Pullout only 250A
Pullout only 800A
Base only, metric
Base only, English
Base only, metric, LED
Base only, English, LED
Base only, metric, alarm
Base only, English, alarm
Amp
rating
70-250
70-250
70-250
70-250
70-250
70-250
300-800
300-800
300-800
300-800
300-800
300-800
Fuse
symbol
TPL-B
TPL-C or TPH
Amp
rating
70-250
300-800
800 max
800 max
800 max
800 max
800 max
800 max
Dimensions - mm (in)
7.62
(0.300)
Type. 4
41.02
(1.615)
Telecom
protection products
66.4
(2.62)
s
25.9
(1.02)
122.43
(4.820)
s s
8.8
(0.34)
12.7
(0.50)
22.2
(0.88)
17.3
(0.68)
100.5 REF
(3.96)
74.6
(2.94)
13.2
(0.52)
s
s
24.8 REF
(0.98)
s
s
105.2
(4.14)
139.7
(5.50)
Typical applications
Telecommunications DC power circuit protection
Compact design is ideal for todays high power,
high-density cabinets
Fuse
symbol
TPL-B
TPL-B
TPL-B
TPL-B
TPL-B
TPL-B
TPL-C or TPH
TPL-C or TPH
TPL-C or TPH
TPL-C or TPH
TPL-C or TPH
TPL-C or TPH
Hardware/
option
Metric
English
Metric, LED
English, LED
Metric, Alarm
English, Alarm
Metric
English
Metric, LED
English, LED
Metric, Alarm
English, Alarm
Specifications
Description: High
current switch for
use with Telepower
fuses Type TPL-B,
TPL-C and TPH.
Available as
complete switch or pullout.
TPHCS800-MAV (shown)
Base may be purchased
separately.
Dimensions: See dimensions illustrations.
Construction:
Ratings:
Volts: 80Vdc
Amps: 70-800A
SCCR: 100kA
Agency information: UL Recognized (investigated to UL
1801) as a disconnect switch for the interruption of load
current by means of withdrawing the fuse carrier. UL
Recognized to meet the requirements for Canadian
Standards.
Catalog
numbers
TPHCS250-M
TPHCS250-E
TPHCS250-ML
TPHCS250-EL
TPHCS250-MAV
TPHCS250-EAV
TPHCS800-M
TPHCS800-E
TPHCS800-ML
TPHCS800-EL
TPHCS800-MAV
TPHCS800-EAV
TPHCS
Tin-Plated
Copper
Terminals
s
s
61.47
(2.420)
39.2 REF
(1.54)
16.76
(0.660)
1. TPHCS250 and TPHCS800 pullouts and bases are the same with exception to the type of
fuse, TPL-B, TPL-C or TPH the pullout will carry.
2. Plastic rated UL 94V0, 140C RTI.
NOTES:
1007July 2015
Eaton.com/bussmannseries
13-9
13
TPL
Dimensions - in (mm)
Specifications
Description: DC power distribution
fuses for use with Telepower 15100,
15200, TP158HC and TPHCS
disconnect systems. For replacement of
Bussmann series UBO fuses a TPL-TA
adapter kit is necessary.
Dimensions: See dimensions
illustrations.
Ratings:
Volts: 170Vdc
Amps: 70-800A
IR: 100kA
Agency information: CE, UL Recognized Guide JFHR2, File
E56412 Bellcore.
2.66"
(67.5mm)
2.19"
(55.6mm)
1.91"
(48.4mm)
0.75"
(19.1mm)
TPLBL
0.33"
70
80
TPL-BC
90
TPL-BD
100
TPL-BE
125
TPL-BF
150
TPL-BG
175
TPL-BH
200
TPL-BK
225
TPL-BL
250
TPL-CN
300
TPL-CO
350
TPL-CR
400
TPL-CU
450
TPL-CV
500
TPL-CZ
600
TPL-CZH
800
3.50"
(88.9mm)
2.44"
(61.9mm)
(38.1mm)
BUSS
1.00"
(25.4mm)
TPLCZ
0.41"
(10.3mm)
1.50"
1.25"
(31.8mm)
Accessories
Spare fuse holders: TPSFH-LB (for TPL-B fuses)
TPSFH-LC (for TPL-C fuses)
13-10
(4.8mm)
Amp
rating
TPL-BB
0.19"
(8.3mm)
Catalog numbers
TPL-BA
(25.4mm)
BUSS
Typical applications
Telecommunications power circuit protection
Catalog
numbers
1.0"
1.16"
(29.4mm)
TM
1007July 2015
Eaton.com/bussmannseries
0.25"
(6.4mm)
TPN
Dimensions - in (mm)
Specifications
Description:
Current-limiting DC
power distribution fuses.
The TPN fuse is
dimensionally similar to
Class R fuses making it
easy to use standard
Class R fuse blocks.
Dimensions: See dimensions illustrations.
Ratings:
Volts: 170Vdc
Amps: 1-600A
IR: 100kA
Agency information: UL Recognized, Guide JFHR2, File
E56412.
Typical applications
Telecommunications power circuit protection
Catalog numbers (amps)
TPN-45
TPN-50
TPN-60
TPN-70
TPN-80
TPN-90
TPN-100
TPN-110
TPN-125
TPN-150
TPN-175
TPN-200
TPN-225
TPN-250
TPN-300
TPN-350
TPN-400
TPN-450
TPN-500
TPN-600
0.56"
(14.3mm)
2"
(50.8mm)
1A to 30A
0.81"
(20.6mm)
3"
(76.2mm)
35A to 60A
5.88"
(149.2mm)
1.06"
(25.4mm)
70A to 100A
7.13"
(181.0mm)
1.56"
(38.1mm)
110A to 200A
8.63"
(219.1mm)
2.38"
(50.8mm)
225A to 400A
10.38"
(263.5mm)
2.88"
(63.5mm)
450A to 600A
Accessories
Spare fuse holders:TPSFH-N30 (for TPN 1-30) TPSFH-N60
(for TPN 35-60)
Catalog
number
RM25030-1CR
RM25030-2CR
RM25030-3CR
RM25060-1CR
RM25060-2CR
RM25060-3CR
RM25100-1CR
RM25100-2CR
RM25100-3CR
RM25200-1CR
RM25200-3CR
RM25400-1CR
RM25400-3CR
RM25600-1CR
RM25600-3CR
Amps
1-30
1-30
1-30
35-60
35-60
35-60
70-100
70-100
70-100
110-200
110-200
225-400
225-400
450-600
450-600
Poles
1
2
3
1
2
3
1
2
3
1
3
1
3
1
3
1007July 2015
Eaton.com/bussmannseries
13-11
Telecom
protection products
TPN-1
TPN-3
TPN-5
TPN-6
TPN-10
TPN-15
TPN-20
TPN-25
TPN-30
TPN-35
TPN-40
13
13
70 Type
Specifications
Description: Indicating type fuse.
Ratings:
Volts: 125Vac/300Vdc
Amps: 110-10A
IR: 1kA @ 300Vdc
Agency information: CE, UL Recognized,
Guide JDYX2, File E19180 Bellcore.
Catalog numbers
Catalog
Amp
numbers
rating
1
1
70P- 10A*
10
15
70R-15100A*
100
18
18
70E- 100A*
100
2
70X-210A
10
1
70F-14A*
4
1
70K-14A*
4
1
70G-12A*
2
3
70H-34A*
4
70I-1A
1
1
1
70A-1 3A*
1 3
70B-2A*
2
70C-3A*
3
1
70J-3 2A
312
70D-5A*
5
70L-6A
6
70M-8A
8
70N-10A
10
GKB-10A
10
72A Plastic CaseDummy
72B Blister PackDummy
Color
code
Gray/Wh
Red/Wh
Yellow
Black
Violet
Violet/Wh
Red
Brown
Pink
White
Orange
Blue
Black/Wh
Grn/Blk
Grn/Wh
Brown/Wh
Violet/Yel
Violet/Yel
Lucent
comcode
ref. no.
100203413
101384550
100203363
100203371
100203405
100203389
100203397
100203322
100203330
100203348
100203355
100203421
103757977
Code/
list no.
KS23751-L10
KS23751-L11
KS23751-L5
KS23751-L6
KS23751-L9
KS23751-L7
KS23751-L8
KS23751-L1
KS23751-L2
KS23751-L3
KS23751-L4
Typical applications
Telecommunications DC power circuit protection
Catalog number 15087
Accessories
Description: Optional color code eyelets used with fuse
holder to indicate fuse amp rating.
Amp
indication
15
100
18
100
1
10
2
10
1
4
1
4
1
2
3
4
1
113
2
3
312
5
6
8
10
Color
code
Red/White
Yellow
Gray/White
Black
Violet
Violet/White
Red
Brown
Pink
White
Orange
Blue
Black/White
Green/Black
Green/White
Brown/White
Violet/Yellow
Specifications
Description: Fuse holder
for 70 type fuses.
Ratings:
Volts: 300Vdc
Amps: 12A
Agency information: CE, UL
Recognized, Guide IZLT2, File
E14853.
Flammability rating: UL 94V0.
1007July 2015
Eaton.com/bussmannseries
Catalog
numbers
1A1706-17
1A1706-01
1A1706-15
1A1706-02
1A1706-03
1A1706-04
1A1706-05
1A1706-06
1A1706-07
1A1706-08
1A1706-09
1A1706-10
1A1706-16
1A1706-11
1A1706-12
1A1706-13
1A1706-14
13
GMT
Specifications
Description: Fuse
holders for GMT
indicating fuses.
Poles: 01 to 25.
Ratings:
Specifications
Description: Fast-acting fuses for use in HLT, HLS, and
PCT fuse holders.
Ratings:
Volts: 60Vdc/125Vac
Amps: 18100-15A
IR: 450A@60Vdc
300A@125Vac
Agency information: CE, UL Recognized, Guide JFHR2,
File E56412.
Flammability rating: UL 94V0.
Volts: 60Vdc/125Vac
Agency information:
CE, UL Recognized,
Guide IZLT2, File
E14853, 15A (60Vdc).
Flammability rating:
UL 94V0.
GMT - Dummy
GMT - A (Alarm)
Typical applications
Telecommunications DC power circuit protection
Poles
1
1-25 see build-a-code
1-25 see build-a-code
Catalog numbers
Termination location
(Left only)
(Right only)
B3
(U bar only)
B5
(L and U bars)
Color
code
White/Blue
White/Brown
Green
Black/White
Red/White
Yellow/Green
Red/Blue
Gray body
Clear cover
Clear cover w/tab
Accessories
Spare fuse holder: catalog number TPSFH-T
GMT-A
Bus bar position
B4
(Angle and L bars)
Catalog
numbers
GMT-3-12A
GMT-4A
GMT-5A
GMT-7-12A
GMT-10A
GMT-12A
GMT-15A
GMT-Dummy
GMT-X
GMT-Y
(Both ends)
B2
(L
bar only)
Color
code
Yellow
Violet
Green/Gray
Red
Black
Brown
Gray
White
White/Yellow
Orange
Blue
Catalog numbers
B1
(Angle bar only)*
Catalog
numbers
GMT-18100A
GMT-14A
GMT-38A
GMT-12A
GMT-65100A
GMT-34A
GMT-1A
GMT-1-13A
GMT-1-12A
GMT-2A
GMT-3A
P1
(Inside
both sides)
P2
(Outside
both sides)
P3
(Outside
right only)
P4
(Outside
left only)
Specifications
Description: Fast-acting fuse designed specifically for use in
the Telepower 15800 (page 13-6) and TP158HC (page
13-7) fused disconnect switches.
Agency information: The GMT-A has the same ratings and
agency approvals as the standard GMT fuses as shown
above.
Catalog numbers
Catalog number
GMT-A
Color code
Yellow
1007July 2015
Eaton.com/bussmannseries
13-13
Telecom
protection products
Catalog numbers
PCT
HLS
HLT
Typical applications
Telecommunications DC power circuit protection
13
Specialty fuses
7 Type
11 Type
Specifications
Description: Fiber tube, threaded ends. Typically used on
wall type main distribution frames and central battery
substations.
Dimensions: See catalog numbers table and dimensions
illustration.
Ratings:
Amps: 7A
Agency information: CE
Specifications
Description: Fiber tube, threaded ends, identical to 7 Type
except for vent slots in fiber tube.
Dimensions: See dimensions illustration.
Ratings:
Amps: 7A
Agency information: CE
Catalog
numbers
7A-7
7T-7
Amp
rating
7
7
Lucent comcode
ref. no.
100863737
100202753
Catalog numbers
Dimension
A length (in)
4.562
4.828
Catalog
number
11C-7
Amp
rating
7
Lucent comcode
ref. no.
100863745
Catalog number
Dimensions - in
4.625"
4.062"
Dimensions - in
A
4.093"
74 Type
Specifications
Description: Flat, non-indicating visible
link element mounted on 1 inch centers
using either No. 6 or No. 10 screws.
Dimensions: See dimensions illustration.
Ratings:
Volts: 32Vdc ( , 1, 3 12, 8, 10A)
60Vdc (12, 34, 1 12, 2, 3, 4, 5A)
Amps: 14-10A
Agency information: CE, UL Recognized File E56412.
Specifications
Description: Fast-acting 0.281 x 1.25 cylindrical fuse
designed to comply with Lucent specification KS23753. High
current companion to 70 Type fuse.
Dimensions: See dimensions illustration.
Ratings:
Volts: 60Vdc
Amps: 1 14-20A
Agency information: CE, UL Recognized File E19180.
Catalog
numbers
WER-14
24E-12*
24D-34*
WER-1
24G-1-13*
24C-2*
24B-3*
WER-3-12
24B-4*
24F-5*
WER-8
WER-10
Amp
rating
1
4
1
2
Catalog numbers
1
1 13
2
3
3 12
4
5
8
10
DC
volts
32
60
60
32
60
60
60
32
60
60
32
32
Color
code
Red
Black
White
Orange
Blue
Yellow
Green
Lucent comcode
ref. no.
100202894
100202886
100202910
100202878
100202852
100202860
100202902
A length
inches
0.20
0.15
0.20
0.20
0.15
0.15
0.15
Catalog
Amp
Lucent comcode
Code/
103064952
KS23753-L7
102630316
KS23753-L3
Catalog numbers
numbers
74A-1-14
74G-2
74B-3
74H-4
74C-5
74J-7-12
74D-10
74E-15
74F-20
rating
1 14
3
4
7 12
10
15
20
ref. no.
102630290
102630308
103264669
103228425
102630324
102630332
102630340
list no.
KS23753-L1
KS23753-L2
KS23753-L8
KS23753-L9
KS23753-L4
KS23753-L5
KS23753-L6
Dimensions - in (mm)
*Designed to comply with Bellcore Technical Reference TR-TSY-000799 Issue 1, Dec. 1988.
Dimensions - in
1.25"
(31.75mm)
1.406"
0.938"
A
A 0.375"
13-14
1007July 2015
Eaton.com/bussmannseries
0.281"
(7.14mm)
13
75 Type
76 Type
Specifications
Description: Cylindrical with leads,
designed to provide protection against
currents resulting from the application of foreign voltages.
Application for data sets and telephones.
Dimensions: See dimensions illustration.
Ratings:
Volts: 135Vac/220Vdc (440Vdc@0.007A)
Amps: 0.007-0.230A
Agency information: CE
Specifications
Description: Cylindrical with leads,
designed to provide protection against
currents resulting from the application
of foreign voltages. Application for data sets and telephones.
Dimensions: See dimensions illustration.
Ratings:
Volts: 135Vac/440Vdc
Amps: 0.012-0.412A
Agency information: CE
Catalog
numbers
Amp
rating
Lucent comcode
ref. no.
Code/
list no.
Catalog
numbers
Amp
rating
75B
0.115
102732112
KS23825-L2
76A
0.231
102810181
Catalog numbers
75C
0.007
75F
0.063
75D
0.129
75A
0.200
75E
0.230
103260816
104172861
104013180
Catalog numbers
KS23825-L3
76D
KS23825-L6
76B
KS23825-L4
102660008
76C
KS23825-L1
104015292
KS23825-L5
0.191
0.412
103798245
KS23825-L10
103656625
KS23825-L9
102965688
KS23825-L7
Dimensions - in (mm)
0.620"
(8.26mm)
KS23825-L8
0.445"
(11.30mm)
0.830"
(21.08mm)
0.325"
Dimensions - in (mm)
0.012
(15.75mm)
Telecom
protection products
0.320"
(8.13mm)
0.190"
1.125"
(4.83mm)
(28.58mm)
0.800"
(20.32mm)
80 Type
Specifications
Description: A fuse designed for high reliability applications
where high ambient temperatures, low circuit voltages, low
power dissipation and low contact resistance are prime
considerations. The 80 Type is a visual indicating fuse with
remote electrical alarm capability. UL Recognized, Guide
JDYX2, File E19180.
Dimensions: See dimensions illustrations.
Ratings:
Volts: 160Vdc
Amps: 12-5A
Agency information: CE, UL Recognized File E19180.
Catalog Amp
numbers rating
Color
code
80B-2
Orange
103752150
Catalog numbers
80G-12
80C-3
80M-1-13
80D-5
113
2
5
Red
White
Blue
Green
103839916
KS23824-L6
408078657
KS23824-L8
KS23824-L2
103752168
KS23824-L3
103800637
KS23824-L4
Dimensions - in (mm)
2.685"
(68.20mm)
0.280"
(7.11mm)
1007July 2015
Eaton.com/bussmannseries
13-15
Surge Protection
Made Simple
UL 508A Applications
Comprehensive UL 1449
3rd Edition recognized Bussmann
series surge protection solutions
for North American applications.
13-16
1007July 2015
Eaton.com/bussmannseries
14
Contents
Description
Page
UL DIN-Rail
High SCCR SPDs
1-pole
2-pole
3-pole
4-pole
Type
Type
Type
Type
2
2
2
2
BSPM_S2G....................................14-14
BSPM_S3G....................................14-16
BSPM_WYG/DLG ..........................14-18
BSPM_WYNG/HLG........................14-20
Type 2
BSPM_LV.......................................14-22
Type 3
BSPH2A_LV ...................................14-24
Class I
Class I
Class I
BSPS_TN/TT..................................14-26
BSPS_TNC ....................................14-28
BSPS_TNS/TT ...............................14-30
Class
Class
Class
Class
IEC DIN-Rail
Class I
2-pole
3-pole
4-pole
Class II
1-pole
2-pole
3-pole
4-pole
II
II
II
II
Class I
BSPS_WE ......................................14-44
Class
Class
Class
Class
BSPM_WE / BSPS_WE..................14-46
BSPM_WE / BSPH_WE .................14-48
BSPM_WE .....................................14-50
BSPM_WE / BSPH_WE .................14-52
Class II
1-pole
2-pole
3-pole
4-Pole
II
II
II
II
BSPD5BNCD_ ...............14-54
BSPD5BNCSI ................14-56
BSPD48RJ45 ................14-58
BSPD_DIN_ ...................14-60
1007July 2015
Eaton.com/bussmannseries
14-1
Surge protection
devices
1-pole PV
2-module PV
3-module PV
3-module PV
14
L1
L2
Dedicated one-pole
circuit breaker,
or one-pole
fusible switch
Dedicated one-pole
circuit breaker,
or one-pole
fusible switch
Black
Black
Black
Dedicated two-pole
common trip
circuit breaker, or
two-pole
fusible switch
Black
White
White
Green
L1
L1
G
L1
G
L2
White
SPH50SP1120SN
SPH50SP2120SNG
SPH50SP2240PN
SPH50SP1240SN
SPH50SP2240SNG
SPH50SP2480PN
SPH50SP1347SN
SPH50SP2347S
SurgePOD PRO:
SurgePOD PRO:
SPP40SP1120SN
14-2
1007July 2015
Eaton.com/bussmannseries
SPP40SP2240PN
14
Volts:
120, 127, 277, 347 (L-N), 208,
220, 480, 600 (L-L)
Dedicated two-pole
common trip
circuit breaker, or
two-pole
fusible switch
Black
Dedicated three-pole
common trip circuit
breaker, or three-pole
fusible switch
Black
White
L1
Green
L2
Dedicated three-pole
common trip circuit
breaker, or three-pole
fusible switch
Black
Black
Black
Black
Black
Black
White
N
L1
L2
L3
Green
L1
L2
L3
Green
SPH50SP3480PNG
SPH50SP3208WYG
SPH50SP4208WYNG
SPH50SP3480WYG
SPH50SP4480WYNG
SPH50SP3600WYG
SPH50SP4600WYNG
SurgePOD PRO:
BSPD
SPP40SP3208WYG
SPHP4SP3480WYG
L2
Dedicated two-pole
common trip
circuit breaker, or
two-pole
fusible switch
Black
Surge protection
devices
Black
White
L1
L2
Green
1007July 2015
Eaton.com/bussmannseries
14-3
14
L3
Dedicated three-pole
common trip circuit
breaker, or three-pole
fusible switch
Black
Black
White
L1
L2
Dedicated three-pole
common trip circuit
breaker, or three-pole
fusible switch
Dedicated three-pole
common trip circuit
breaker, or three-pole
fusible switch
Black
Black
Black
Black
Orange
Black
Black
Green
L3
White
G
L1
L2
L3
Green
L1
L2
L3
Green
SPH50SP4208WYNG
SPH50SP3240DLG
SPH50SP4240HLG
SPH50SP4480WYNG
SPH50SP3480DLG
SPH50SP4480HLG
SPH50SP4600WYNG
SurgePOD PRO:
BSPD
SPP40SP3240DLG
SPP40SP3480DLG
BSPD
14-4
1007July 2015
Eaton.com/bussmannseries
14
Agency information
Basic, Standard and Standard with Surge
Counter configurations UL Listed, 1449 3rd
Edition, File E316410, Guide VZCA, CSA
Certified, Notice 516, File 243397
Description
The BSPD Surge Protective Devices (SPDs) deliver reliable
surge protection with high surge current capacity for system
switchboards and power distribution panels.
Applications
BSPD units are available for common Delta and Wye system
voltages in a variety of surge current capacity ratings from
120kA to 400kA. Available in three configurations, the BSPD
Series features and options make it easy to specify units for
many electrical applications including service entrances,
distribution switchboards, panelboards and point-of-use. All
possible combinations of product attributes are available for
ordering in the Catalog number system.
Prewired
All BSPD units are factory wired for ease of installation. Simply
install any necessary conduit runs, mount the unit and make
all wire connections. No need for internal wiring or access to
the units inside.
1007July 2015
Eaton.com/bussmannseries
14-5
Surge protection
devices
14
Basic
(Type 1)
Standard
(Type 2)
Standard
with Surge
Counter
(Type 2)
Two color LED protection status indicators for the neutral-ground protection mode (Wye systems only)
Features
Dimensions - in (mm)
7.28
(184.9)
5.27
(133.9)
1.00
(25.4)
5.47
(138.9)
10.48
(266.2)
12.05
(306.1)
12.05
(306.1)
10.48
(266.2)
0.68
(17.3)
5.24
(133.1)
0.78
(19.8)
11.25
(285.8)
11.25
(285.8)
0.67
(17.0)
5.24
(133.1)
2.00
(50.8)
3.48
(88.4)
4.41
(112.0)
0.20
(5.1)
7.47
(189.7)
0.40
(10.2)
0.78
(19.8)
2.00
(50.8)
5.76
(146.3)
0.20
(5.1)
7.47
(189.7)
6.69
(169.9)
120-200kA
250-400kA
A
2.60 (66.0)
4.10 (104.1)
B
5.39 (137.0)
7.68 (195.0)
14-6
1.00
(25.4)
1007July 2015
Eaton.com/bussmannseries
COMMON
NORMALLY OPEN
NORMALLY CLOSED
0.40
(10.2)
14
Enclosure rating
Series
BSPD
K = NEMA 1
P = NEMA 4X
kA Rating
per phase
120kA
200kA
300kA
400kA
Configurations
1007July 2015
Eaton.com/bussmannseries
Surge protection
devices
1 = Basic
Green and red LEDs per phase to indicate protection status
Green and red LEDs on Wye units to indicate protection status of the Neutral-to-Ground mode
2 = Standard
Green and red LEDs per phase to indicate protection status
Green and red LEDs on Wye units to indicate protection status of the Neutral-to-Ground mode
Audible alarm with Silence button
Form C contact relay. Specifications 150Vac / 125Vdc, 1A max
EMI/RFI filtering providing up to 50dB of noise attenuation from 10kHz to 100MHz
3 = Standard With Surge Counter
Green and red LEDs per phase to indicate protection status
Green and red LEDs on Wye units to indicate protection status of the Neutral-to-Ground mode
Audible alarm with silence button
Form C contact relay
EMI/RFI filtering providing up to 50dB of noise attenuation from 10kHz to 100MHz
Surge counter with reset button
14-7
14
Description
SPD Type 2
easyID LED
status indicator
SPH50SP1120SN
SPH50SP1240SN
SPH50SP1347SN
SPH50SP2120SNG
SPH50SP2240SNG
SPH50SP2347SNG
SPH50SP2240PN
SPH50SP2480PN
SPH50SP3600WYG
SPH50SP4208WYNG
SPH50SP4480WYNG
SPH50SP4600WYNG
Dimensions - in
1-1/16 Dia.
SPH50SP3240PNG
SPH50SP3480PNG
SPH50SP3240DLG
SPH50SP3480DLG
SPH50SP4240HLG
SPH50SP4480HLG
SPH50SP3208WYG
SPH50SP3480WYG
1-11/16
3-3/8
1-11/16
Surge Rating
50S = 50kA max discharge current
2-1/16
2-1/16
4-1/8
No of Wires/Poles
P1 = 1
P2 = 2
P3 = 3
P4 = 4
System
SN = Single-phase 2 wire, 2 Connection Points
SNG = Single-phase 2 wire + G, 3 Connection Points
PN = Split-phase 3 wire , 3 Connection Points
PNG = Split-phase 3 wire + G, 4 Connection Points
DLG = Three-phase delta 3 wire + G, 4 Connection Points
HLG = Three-phase highleg delta 4 wire + G, 5 Connection Points
WYG = Three-phase wye 3 wire, 4 Connection Points
WYNG = Three-phase wye 3 wire + G, 5 Connection Points
7/8
14-8
1007July 2015
Eaton.com/bussmannseries
14
Catalog number
Nominal
system voltage
Max. continuous
operating AC voltage
(MCOV) (VC)
Connection
points
System type
SPH50SP1120SN
120V
150V
Single-phase 2 Wire
SPH50SP1240SN
240V
320V
Single-phase 2 Wire
SPH50SP1347SN
347V
420V
Single-phase 2 Wire
SPH50SP2120SNG
120V
150V
Single-phase 2 Wire + G
SPH50SP2240SNG
240V
320V
Single-phase 2 Wire + G
SPH50SP2347SNG
347V
420V
Single-phase 2 Wire + G
120/240V
150V
Split-phase 3 Wire
SPH50SP2240PN
SPH50SP2480PN
240/480V
320V
Split-phase 3 Wire
SPH50SP3240PNG
120/240V
150V
Split-phase 3 Wire + G
SPH50SP3480PNG
240/480V
320V
Split-phase 3 Wire + G
SPH50SP3240DLG
240V
320V
SPH50SP3480DLG
480V
550V
SPH50SP4240HLG
120/240V
150/320V
SPH50SP4480HLG
240/480V
320/550V
SPH50SP3208WYG
208V
150V
SPH50SP3480WYG
480V
320V
SPH50SP3600WYG
600V
420V
SPH50SP4208WYNG
208Y/120V
150V
SPH50SP4480WYNG
480Y/277V
320V
SPH50SP4600WYNG
600Y/347V
420V
Values
200kA
20kA
50kA
<25ns
Frequency
Operating state/fault indication
Conductor length / gauge
50/60Hz
Bi-color LED - Green (good) / Red (replace)
18 inches, 10 AWG stranded copper
Mounting
NEMA 4X - UL 94-5VA
IP20 (finger-safe)
Indoor/outdoor
Lineside or loadside of service entrance overcurrent protective device
Operating temperature
-40C to +85C
Surge protection
devices
16,000FT
cULus, CSA**, RoHS Compliant
Standard
Warranty
Five Years***
* Customer-supplied bracket.
** 600V Wye version is CSA Certified.
*** See SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/Surge.
1007July 2015
Eaton.com/bussmannseries
14-9
14
Catalog number
Rated system
voltage (Vo)
MCOV (VC)
L-N
L-L
L-G
N-G
SPH50SP1120SN
120V
150V
700
SPH50SP1240SN
240V
320V
1200
SPH50SP1347SN
347V
420V
1500
SPH50SP2120SNG
120V
150V
700
1200
700
SPH50SP2240SNG
240V
320V
1200
2500
1200
SPH50SP2347SNG
347V
420V
1500
2500
1500
SPH50SP2240PN
120V/240V
150V
700
1200
SPH50SP2480PN
240V/480V
320V
1200
2500
SPH50SP3240PNG
120V/240V
150V
700
1200
1200
700
SPH50SP3480PNG
240V/480V
320V
1200
2500
2500
1200
SPH50SP3240DLG
240V
320V
2500
1200
SPH50SP3480DLG
480V
550V
3000
1800
SPH50SP4240HLG
120/240V
150V/320V
700/1200
1200/2500
1200/2500
700/1200
SPH50SP4480HLG
240/480V
320V/550V
1200/1800
2500/3000
2500/3000
1200/1800
SPH50SP3208WYG
208V
150V
1200
700
SPH50SP3480WYG
480V
320V
2500
1200
SPH50SP3600WYG
600V
420V
2500
1500
SPH50SP4208WYNG
208Y/120V
150V
700
1200
1200
700
SPH50SP4480WYNG
480Y/277V
320V
1200
2500
2500
1200
SPH50SP4600WYNG
600Y/347V
420V
1500
2500
2500
1500
SPD voltages are measured from Line-to-Neutral, or Line-to-Ground on systems where there is no Neutral present. These units do not have a Line-to-Neutral, so the
Line-to-Ground voltage is 120V for the 208V Wye L-G, 277V for the 480V L-G and 347V for the 600V Wye L-G, making the norman voltage applied to the unit less than
the MCOV values listed in the table.
600V Wye version is not CSA Certified.
Mounting
The easyID LED status indicator will illuminate when the unit is
properly installed and the system or equipment being protected is
energized. The following LED color/status indicates:
Tighten locknut to
20.3 Lb-In (2.3Nm)
14-10
1007July 2015
Eaton.com/bussmannseries
14
Description
The Bussmann series SurgePOD PRO is a Type 1 UL Listed
1449 3rd Edition surge protective device suitable for
installation on both the loadside or lineside of the service
entrance overcurrent protective device.
Available in popular voltage and system specific versions to
match common residential and light commercial electrical
system and equipment requirements. The SurgePOD PRO
delivers superior surge protection using MOV thermal
disconnect technology that eliminates the need for additional
overcurrent protection.
easyID LED
status indicator
Dimensions - in
SPP40SP1120SN
SPP40SP2240PN
SPP40SP3240DLG SPP40SP3208WYG
SPP40SP3480DLG SPP40SP3480WYG
Surge protection
devices
1-1/16 Dia.
1-11/16
3-3/8
1-11/16
40S
PX
XXX
XXX
Surge rating
40S = 40kA max discharge current
No of wires/poles
2-1/16
2-1/16
4-1/8
P1 = 1
P2 = 2
P3 = 3
3-3/16
4-1/16
7/8
System
SN = Single-phase 2 wire, 2 Connection Points
PN = Split-Phase, 3 Wire, 3 Connection Points
DLG = Three-phase delta 3 wire + G, 4 Connection Points
WYG = Three-phase wye 3 wire, 4 Connection Points
1007July 2015
Eaton.com/bussmannseries
14-11
14
Catalog number
Max. continuous
operating AC
voltage (MCOV) (VC)
SPP40SP1120SN
120V
150V
Single-phase 2 Wire
SPP40SP2240PN
Connection
points
System type
120/240V
150V
Split-phase 3 Wire
SPP40SP3240DLG
240V
320V
SPP40SP3480DLG
480V
550V
SPP40SP3208WYG
208V
150V
SPP40SP3480WYG
480V
320V
Values
200kA
10kA
40kA
<25ns
Frequency
50/60Hz
Mounting
NEMA 4X - UL 94-5VA
IP20 (finger-safe)
Indoor/outdoor
Circuit location
Operating Temperature
-40C to +65C
12,000FT
Agency information
Standard
Warranty
Two Years**
* Customer-supplied bracket.
** See SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/Surge.
Catalog number
Nominal system
voltage
MCOV (VC)
L-N
L-L
L-G
SPP40SP1120SN
120V
150V
700
SPP40SP2240PN
120V/240V
150V
700
1200
SPP40SP3240DLG
240V
320V
2500
1200
SPP40SP3480DLG
480V
550V
3000
1800
SPP40SP3208WYG
208V
150V
1200
700
SPP40SP3480WYG
480V
320V
2500
1200
SPD voltages are measured from Line-to-Neutral, or Line-to-Ground on systems where there is no Neutral present. These units do not have a Line-to-Neutral, so the
Line-to-Ground voltage is 120V for the 208V Wye L-G and 277V for the 480V L-G, making the norman voltage applied to the unit less than the MCOV values listed in
the table.
14-12
1007July 2015
Eaton.com/bussmannseries
14
Mounting
The easyID LED status indicator will illuminate when the unit is
properly installed and the system or equipment being protected is
energized. The following LED color/status indicates:
Tighten locknut to
20.3 Lb-In (2.3Nm)
1007July 2015
Eaton.com/bussmannseries
14-13
14
BSPM_ _ _ _S2G
Dimensions - mm
Remote Signal
Contact Available
Specifications
Description
Circuit diagram
MOV
12
11
14
12
11
14
Thermal
Disconnector
Gnd/N
BSPM1120S2G, BSPM1240S2G, BSPM1347S2G
Shown with optional remote contact signaling
For remote signaling contact, add R suffix to the part number,
E.g., BSPM1347S2GR
Optional Remote
Signal Contact
1007July 2015
Eaton.com/bussmannseries
14
Ordering information
Nominal system voltage
120Vac
275Vac
385Vac
600Vac
BSPM1120S2G
BSPM1240S2G
BSPM1347S2G
BSPM1120S2GR
BSPM1240S2GR
BSPM1347S2GR
BPM275UL
BPM385UL
BPM600UL
120-127Vac
240-277Vac
347Vac
1kV
1.5kV
2kV
200kA
200kA
125kA
Catalog numbers:
Replacement module
347Vac
Specifications
Rated voltage
Voltage Protection Rating VPR
Short-circuit Current Rating (SCCR)
Nominal discharge current (In)
20kA
40kA
25ns
Frequency
50/60Hz
Number of poles
-40C to +80C
Terminal torque
45 lb-in
Mounting
Enclosure material
Thermoplastic, UL 94V0
Degree of protection
IP20 (finger-safe)
Location category
Indoor
Capacity
Application
Agency information
Standard
Surge protection
devices
Warranty
Five years*
Remote contact signaling
Changeover contact
250V/0.5A
Ordering information
L1
L2
L1
L3
120, 240, 347Vac 2 wire systems
See document 3A1636 for black label single-pole UL SCCR rated BSPM installation instructions.
BUSSMANN SERIES FULL LINE CATALOG
1007July 2015
Eaton.com/bussmannseries
14-15
14
BSPM_ _ _ _S3G
Dimensions - mm
Remote Signal
Contact Available
Description
Circuit diagram
L1
MOV
12
11
14
12
11
14
Gnd/N
Gnd/N
BSPM2240S3G, BSPM2480S3G
Shown with optional remote contact signaling
For remote signaling contact, add R suffix to the part number,
E.g., BSPM2480S3GR
Optional Remote
Signal Contact
Thermal
Disconnector
14-16
L2
1007July 2015
Eaton.com/bussmannseries
14
Ordering information
Nominal system voltage
120/240, 240Vac
Catalog numbers:
Replacement module
MOV technology
240/480Vac
275/550Vac
385/770Vac
BSPM2240S3G
BSPM2480S3G
BSPM2240S3GR
BSPM2480S3GR
BPM275UL
BPM385UL
120-127Vac, 240-254Vac,
240Vac
240-480Vac, 480Vac
1kV/1.8kV
1.5kV/2.5kV
Specifications
Rated voltage
Voltage Protection Rating VPR [L-G/L-L]
Short-Circuit Current Rating (SCCR)
200kA
20kA
40kA
25ns
Frequency
50/60Hz
Number of poles
-40C to +80C
Terminal torque
45 lb-In
Mounting
Enclosure material
Thermoplastic, UL 94V0
Degree of protection
IP20 (finger-safe)
Location category
Indoor
Capacity
Application
Agency information
Standard
Surge protection
devices
Product warranty
Five years*
Remote contact signaling
Changeover contact
250V/0.5A
Conductor ratings and cross-sectional area for remote contact signal terminals
Ordering Information
L
N
L
L1
L2
N
L1
L1
L2
L2
L3
120/240V, 240/480Vac
Single-phase (split) center tap
BSPM2240S3G, BSPM2480S3G
120/208V, 277/480Vac
3 wire Wye system
BSPM2240S3G, BSPM2480S3G
1007July 2015
Eaton.com/bussmannseries
14-17
14
Dimensions - mm
Remote Signal
Contact Available
Description
Circuit diagrams
L1
L2
MOV
12
11
14
12
11
14
Optional Remote
Signal Contact
Thermal
Disconnector
Gnd
Gnd
L3
1007July 2015
Eaton.com/bussmannseries
14
Ordering information
Nominal system voltage
120/208Vac
240Vac
277/480Vac
480Vac
347/600Vac
275/550Vac
275/550Vac
385/770Vac
600/1200Vac
600/1200Vac
BSPM3208WYG
BSPM3240DLG
BSPM3480WYG
BSPM3480DLG
BSPM3600WYG
BSPM3208WYGR
BSPM3240DLGR
BSPM3480WYGR
BSPM3480DLGR
BSPM3600WYGR
BPM275UL
BPM275UL
BPM385UL
BPM600UL
BPM600UL
Catalog numbers:
Without remote
signaling
With remote signaling
Replacement module
MOV technology
Specifications
Rated Voltage
Voltage Protection Rating VPR [L-G/L-L]
Short-Circuit Current Rating (SCCR)
120-127Vac,
208-220Vac
240Vac
277/480Vac
480Vac
347/600Vac
1kV/1.8kV
1kV/1.8kV
1.5kV/2.5kV
2kV/4kV
2kV/4kV
200kA
200kA
200kA
125kA
125kA
20kA
40kA
25ns
Frequency
50/60Hz
Number of poles
-40C to +80C
Terminal torque
45 lb-In
Mounting
Enclosure material
Thermoplastic, UL 94V0
Degree of protection
IP20 (finger-safe)
Location category
Indoor
Capacity
Application
Agency information
Standard
Warranty
Five years*
Remote Contact Signaling
Changeover contact
250V/0.5A
Ordering information
L1
L2
L1
L1
L2
L2
L3
L3
L3
240, 480Vac
Delta 3-phase, 3 wire + ground
BSPM3240DLG, BSPM3480DLG
1007July 2015
Eaton.com/bussmannseries
14-19
14
Dimensions - mm
Remote Signal
Contact Available
Description
Circuit diagram
L1
L2
MOV
12
11
14
12
11
14
Optional Remote
Signal Contact
Thermal
Disconnector
Gnd
Gnd
L3
1007July 2015
Eaton.com/bussmannseries
14
Ordering information
120/208Vac,
127/220Vac
Catalog numbers
Replacement
modules
MOV technology
four (4) total
required
240/480Vac
277/480Vac
347/600Vac
[L-N]/[L-G]
275/550Vac
275/550Vac
385/770Vac
385/660Vac
600/875Vac
[N-G]/[L-L]
275/550Vac
275/550Vac
385/770Vac
275/770Vac
275/1200Vac
[H-N]/[H-G]
275/550Vac
600/985Vac
[H-L]
550Vac
985Vac
BSPM4208WYNG
BSPM4240HLG
BSPM4480HLG
BSPM4480WYNG
BSPM4600WYNG
120/240Vac
BSPM4208WYNGR
BSPM4240HLGR
BSPM4480HLGR
BSPM4480WYNGR
BSPM4600WYNGR
L1 or L3
BPM275UL
BPM275UL
BPM385UL
BPM385UL
BPM600UL
L2
BPM275UL
BPM275UL
BPM600UL
BPM385UL
BPM600UL
BPM275UL
BPM275UL
BPM385UL
BPM275UL
BPM275UL
Specifications
120/208Vac,
127/220Vac
120/240Vac
240/480Vac
277/480Vac
347/600Vac
[L-N/L-G]
1kV/1.8kV
1kV/1.8kV
1.5kV/2.5kV
1.5kV/2.5kV
2kV/3kV
[N-G/L-L]
1kV/1.8kV
1kV/1.8kV
1.5kV/2.5kV
1kV/2.5kV
1kV/4kV
[H-N/H-G]
1kV/1.8kV
2kV/3kV
[H-L]
1.8kV
3kV
200kA
200kA
125kA
200kA
125kA
Rated Voltage
20kA
40kA
25ns
Frequency
50/60Hz
Number of poles
-40C to +80C
Mounting
Surge protection
devices
Terminal torque
Enclosure material
Thermoplastic, UL 94V0
Degree of protection
IP20 (finger-safe)
Location category
Indoor
Capacity
Application
Agency information
Standard
Warranty
Five years*
Changeover contact
250V/0.5A
Ordering information
L2
L1
L2
(Highleg)
L3
BSPM4208WYNG, BSPM4480WYNG,
BSPM4600WYNG
L1
N
L3
120/240V, 240/480Vac
Highleg Delta, 3-phase, 4 wire + ground
BSPM4240HLG, BSPM4480HLG
See document 3A1639 for black label four-pole UL SCCR rated BSPM installation instructions.
Data Sheet: 2152
BUSSMANN SERIES FULL LINE CATALOG
1007July 2015
Eaton.com/bussmannseries
14-21
14
BSPM1A_ _ _ _LV
Dimensions - mm
Remote signal
contact available
Description
The Bussmann series UL Type 4 48Vac/60Vdc,
75Vac/100Vdc, 120Vac/200Vdc, 275VAc/350Vdc,
320Vac/420Vdc, 385Vac/500Vdc, 440Vac/585Vdc and
600Vac/dc single pole, modular surge arresters feature local,
easy ID visual indication and optional remote contact
signaling. The unique module locking system fixes the
protection module to the base part. Modules can be easily
replaced without tools by simply depressing the release
buttons. Integrated mechanical coding between the base and
protection module ensures against installing an incorrect
replacement module.
Thermal Disconnector
MOV
BSPM1A48D60LV, BSPM1A75D100LV,
BSPM1A150D200LV,
BSPM1A275D350LV, BSPM1A320D420LV,
BSPM1A385D500LV, BSPM1A440D585LV,
BSPM1A600D600LV
Shown with optional remote contact signaling
1007July 2015
Eaton.com/bussmannseries
14
48Vac/60Vdc
75Vac/100Vdc
120Vac/200Vdc
275Vac/350Vdc
BSPM1A48D60LV
BSPM1A75D100LV
BSPM1A150D200LV
BSPM1A275D350LV
BSPM1A48D60LVR
BSPM1A75D100LVR
BSPM1A150D200LVR
BSPM1A275D350LVR
BPMA48D60LV
BPMA75D100LV
BPMA150D200LV
BPMA275D350LV
Replacement Modules
Specifications
48Vac
75Vac
150Vac
275Vac
0.33kV
0.4kV
0.7kV
1.5kV
0.25kV
0.35kV
0.55kV
1kV
60Vdc
100Vdc
200Vdc
350Vdc
7.5kA
10kA
15kA
20kA
7.5kA
10kA
12.5kA
12.5kA
25kA
40kA
40kA
40kA
70V / 5 sec.
90V / 5 sec.
175V / 5 sec.
335V / 5 sec
320Vac/420Vdc
385Vac/500Vdc
440Vac/585Vdc
600Vac/600Vdc
BSPM1A320D420LV
BSPM1A385D500LV
BSPM1A440D585LV
BSPM1A600D600LV
BSPM1A320D420LVR
BSPM1A385D500LVR
BSPM1A440D585LVR
BSPM1A600D600LVR
BPMA320D420LV
BPMA385D500LV
BPMA440D585LV
BPMA600D600LV
Replacement modules
Specifications
Max. continuous operating AC voltage [VC]
320Vac
385Vac
440Vac
600Vac
420Vdc
500Vdc
585Vdc
600Vdc
1.5kV
1.75kV
2kV
2.5kV
1.2kV
1.35kV
1.7kV
2kV
20kA
20kA
20kA
15kA
12.5kA
5kA
5kA
5kA
40kA
40kA
40kA
30kA
335V / 5 sec.
385V / 5 sec.
580V / 5 sec.
600V / 5 sec.
Type 2
Class II
25ns
TOV characteristics
Withstand
-40C to +80C
Number of ports
14AWG solid/stranded
Mounting
Enclosure material
Thermoplastic, UL 94V0
Location category
Indoor
Degree of protection
IP20
Capacity
Warranty
Five Years**
Changeover contact
250V/0.5A
See document 3A1502 for blue label one-pole low voltage power non-SCCR rated BSPM installation instructions.
Data Sheet: 2056
BUSSMANN SERIES FULL LINE CATALOG
1007July 2015
Eaton.com/bussmannseries
14-23
14
BSPH2A_ _ _ _LV(R)
Dimensions - mm
Remote signal
contact available
Specifications
Description
The Bussmann series UL Type 4 24Vac/dc, 48Vac/dc,
60Vac/dc, 120Vac/dc and 230Vac/dc, two-pole, modular surge
arresters feature local, easy ID visual indication and optional
remote contact signaling. The unique module locking system
fixes the protection module to the base part. Modules can be
easily replaced without tools by simply depressing the release
buttons. Integrated mechanical coding between the base and
protection module ensures against installing an incorrect
replacement module.
LV system arresters
The features of these two-pole devices are for use in
coordination with other upstream SPDs in UL 508A
Applications*.
Surge arrester according to UL 1449 3rd Edition,
Type 4 Component Assembly for use in Type 3 applications
helps meet UL 508A requirements
Proven MOV and GDT hybrid technology for reliable surge
protection
"Thermo Dynamic Control" SPD monitoring device ensures
high reliability against surge events
Module locking system with module release button make
module replacement easy without tools
Optional remote signaling of all protection modules make
status monitoring easy and accurate in any monitoring
scheme
No additional upstream overcurrent protection necessary to
make installation easier and more economical
Vibration and shock tested according to EN 60068-2 to
withstand harsh environments
MOV
BPH2A24D24LV
BPH2A48D48LV BPH2A60D60LV
BPH2A150D150LV BPH2A230D230LV
1007July 2015
Eaton.com/bussmannseries
14
Ordering information
System Voltage
24Vac/dc
48Vac/dc
60Vac/dc
120Vac/dc
230Vac/dc
30Vac/dc
60Vac/dc
75Vac/dc
150Vac/dc
255Vac/dc
Catalog numbers
(base + modules)
BSPH2A24D24LV
BSPH2A48D48LV
BSPH2A60D60LV
BSPH2A150D150LV
BSPH2A230D230LV
BSPH2A24D24LVR
BSPH2A48D48LVR
BSPH2A60D60LVR
BSPH2A150D150LVR
BSPH2A230D230LVR
BPHA24D24LV
BPHA48D48LV
BPHA60D60LV
BPHA150D150LV
BPHA230D230LV
Replacement Modules
Specifications
Nominal AC voltage [Vo]
24V
48V
60V
120V
230V
30V
60V
75V
150V
255V
30V
60V
75V
150V
255V
1kA
1kA
2kA
2kA
3kA
2kA
2kA
4kA
4kA
5kA
25A
25A
25A
25A
25A
2kV
2kV
4kV
4kV
6kV
4kV
4kV
8kV
8kV
10kV
180V
350V
400V
640V
1250V
630V
730V
730V
800V
1500V
335V / 5 sec.
400V / 5 sec.
1200V + V0 / 20
Withstand
Withstand
Failure
Type 3
Class III
25ns
100ns
-40C to +80C
Green (good) / Red (replace)
Surge protection
devices
Number of ports
18AWG solid/stranded
For mounting on
Enclosure material
Thermoplastic, UL 94V0
Location category
Indoor
Degree of protection
IP20
Capacity
Agency information*
Product warranty
Five years**
Changeover contact
250V/0.5A
1007July 2015
Eaton.com/bussmannseries
14-25
14
Dimensions - mm
Remote signal
contact available
Circuit diagrams
Description
The Bussmann series IEC Class I 230V, two-pole, modular
combined lightning, current and surge arresters feature local,
easy ID visual indication and optional remote contact
signaling. The unique module locking system fixes the
protection module to the base part. Modules can be easily
replaced without tools by simply depressing the release
buttons. Integrated mechanical coding between the base and
protection module ensures against installing an incorrect
replacement module.230V models are offered with MCOV
rating of 255V.
TN system arresters
The features of these two-pole devices are for use as a
modular combined lightning and current arrester and surge
arrester for use in single TN- systems (2-0 circuit).
TT system arrester
Provides a current arresting means for use in single
TT- systems (1-1 circuit).
Optional remote signaling Form C contact
The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.
BSPS2255TN
BSPS2255TT
1007July 2015
Eaton.com/bussmannseries
14
Ordering information
System voltage/poles
Max. continuous operating AC voltage (MCOV) [UC]
Catalog numbers:
Without remote signaling
With remote signaling
Replacement modules:
MOV technology
Spark Gap technology
230V/2
255V
BSPS2255TN
BSPS2255TNR
(2X) BPS255IEC
--
230V/2
255V
BSPS2255TT
BSPS2255TTR
(1X) BPS255IEC
(1X) BPS50NPEIEC*
625.00 kJ/ohms
25kA
156.25 kJ/ohms
<
_ 1.5 kV/<
_ 1.5 kV
-50kA rms
---
-25/50kA Is [L-N]/[N-PE]
156.25kJ/ohms/
625.00 kJ/ohms
-<
_ 1.5kV/<
_ 1.5kV
-50kA rms/100A rms
1200V/200 ms
Specifications
Cross-sectional area (L , N ,
For mounting on
Enclosure material
Location category
Degree of protection
Capacity
Agency Information
Product warranty
Surge protection
devices
Type 1/Class I
Type 1 + Type 2
Type 1 + Type 2 + Type 3
230V
50kA
25/50kA
no tripping of a 20A gL/gG fuse up to 50kA rms (prosp.)
<
_ 100 ns
315A gL/gG
200A gL/gG
125A gL/gG
440V/5 sec.
withstand
-40C to +80C
-40C to +60C
-40C to +80C/-40C to +60C
green (good)/red (replace)
1
10mm2 solid/flexible
50mm /1AWG stranded-35mm2/2AWG flexible
) [min.]
) [max.]
Changeover contact
250V/0.1A
250V/0.1A; 125V/0.2A; 75V/0.5A
60/75C Max. 1.5mm2/14AWG Solid/Flexible
Order from catalog numbers above
* N-PE Surge arrester for location between neutral conductor and protective conductor
in TT systems.
** See SPD Limited Warranty Statement (3A1502) for details at
www.cooperbussmann.com/surge.
1007July 2015
Eaton.com/bussmannseries
14-27
14
BSPS_ _ _ _TNC
Dimensions - mm
Remote signal
contact available
Circuit diagrams
Description
The Bussmann series IEC Class I 230V, three-pole, modular
combined lightning, current and surge arresters feature local,
easy ID visual indication and optional remote contact
signaling. The unique module locking system fixes the
protection module to the base part. Modules can be easily
replaced without tools by simply depressing the release
buttons. Integrated mechanical coding between the base and
protection module ensures against installing an incorrect
replacement module.
230V models are offered with a MCOV rating of 255V.
TNC system arrester
The features of these three-pole devices are for use in
TN-C 230/400V systems (3-0 circuit) against surges.
Optional remote signaling Form C contact
The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.
BSPS3255TNC
Shown with optional remote contact signaling
1007July 2015
Eaton.com/bussmannseries
14
Ordering information
System voltage/poles
Max. continuous operating AC voltage (MCOV) [UC]
Catalog numbers:
Without remote signaling
With remote signaling
Replacement module
MOV technology
230/400V/3
255V
BSPS3255TNC
BSPS3255TNCR
BPS255IEC
Specifications
Type 1/Class I
Type 1 + Type 2
Type 1 + Type 2 + Type 3
230/400V
75kA
1.40 MJ/ohms
25kA
156.25kJ/ohms
25/75kA
<
_ 1.5kV
50kA rms
no tripping of a 20A gL/gG fuse up to 50kA rms (prosp.)
<
_ 100 ns
315A gL/gG
200A gL/gG
125A gL/gG
440V/5 sec.
withstand
-40C to +80C/-40C to +60C
green (good)/red (replace)
1
2
10mm solid/flexible
50mm2/1AWG stranded-35mm2/2AWG flexible
35mm2/2AWG stranded-25mm2/4AWG flexible
35mm DIN rail per to EN 60715
Thermoplastic, UL 94V0
Indoor
IP20
6 mods., DIN 43880
KEMA
Five years*
Changeover contact
250V/0.1A
250V/0.1A; 125V/0.2A; 75V/0.5A
60/75C Max. 1.5mm2/14AWG Solid/Flexible
Order from catalog numbers above
Size
00
0
01
1
1007July 2015
Eaton.com/bussmannseries
14-29
Surge protection
devices
14
Dimensions - mm
Circuit diagrams
Remote signal
contact available
Description
The Bussmann series IEC Class I 230V, four-pole, modular
combined lightning, current and surge arresters feature local,
easy ID visual indication and optional remote contact
signaling. The unique module locking system fixes the
protection module to the base part. Modules can be easily
replaced without tools by simply depressing the release
buttons. Integrated mechanical coding between the base and
protection module ensures against installing an incorrect
replacement module.
230V models are offered with MCOV ratings of 255V.
TNS system arresters
The features of these four-pole devices are for use in TNS
230/400V systems (4-0 circuit) against surges.
TT system arrester
Provides a current arresting means between neutral
conductor and protective conductor in TT 230/400V systems
(3+1 circuit) against surges.
Optional remote signaling Form C contact
The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.
BSPS4255TNS
Shown with optional
remote contact signaling
BSPS4255TT
Shown with optional
remote contact signaling
For remote signaling contact, add R suffix to the part number,
E.g., BSPS4255TTR
Data Sheet: 1165
14-30
1007July 2015
Eaton.com/bussmannseries
14
Ordering information
System voltage/poles
Max. continuous operating AC voltage (MCOV) [UC]
Catalog numbers:
Without remote signaling
With remote signaling
Replacement modules:
MOV technology
Spark gap technology
230/400V/4
255V
BSPS4255TNS
BSPS4255TNSR
BPS255IEC
--
230/400V/4
255V
BSPS4255TT
BSPS4255TTR
BPS255IEC
BPS100NPEIEC*
Specifications
Type 1/Class I
Type 1 + Type 2
Type 1 + Type 2 + Type 3
230/400V
100kA
2.50MJ/ohms
25kA
156.25kJ/ohms
156.25kJ/ohms/2.50kJ/ohms
25/100kA
<
_ 1.5kV/<
_ 1.5kV
50kA rms
50kA rms/100A rms
No tripping of a 20A gL/gG fuse up to 50kA rms (prosp.)
<
_ 100 ns
315A gL/gG
200A gL/gG
125A gL/gG
440V/5 sec.
1200V/200mS
Withstand
-40C to +80C/-40C to +60C
green (good)/red (replace)
1
2
10mm solid/flexible
50mm2/1AWG stranded-35mm2/2AWG flexible
35mm2/2AWG stranded-25mm2/4AWG flexible
35mm DIN Rail per EN 60715
Thermoplastic, UL 94V0
Indoor
IP20
8 mods., DIN 43880
KEMA
Five years**
Surge protection
devices
Changeover contact
250V/0.1A
250V/0.1A; 125V/0.2A; 75V/0.5A
60/75C Max. 1.5mm2/14AWG Solid/Flexible
Order from catalog numbers above
* N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems.
** See SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
Size
00
0
01
1
1007July 2015
Eaton.com/bussmannseries
14-31
14
Dimensions - mm
Remote signal
contact available
Description
The Bussmann series IEC Class II 275, 320, 385, 440 and
600V, one-pole, modular surge arresters feature local,
easy ID visual indication and optional remote contact
signaling. The unique module locking system fixes the
protection module to the base part. Modules can be easily
replaced without tools by simply depressing the release
buttons. Integrated mechanical coding between the base and
protection module ensures against installing an incorrect
replacement module.
Class II single-pole surge arrester models are offered with
MCOV ratings of 255, 275, 320, 385, 440 and 600V.
TN system arresters
The features of these single-pole devices are for use as a
single device or in combination with other devices.
TT system arrester
Provides a current arresting means between neutral
conductor and protective conductor in TT systems, this
device helps ensure fulfilling the requirements for protection
of personnel and equipment in 3+1 and 1+1 circuits.
Optional remote signaling Form C contact
The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.
MOV
Thermal Disconnector
Gas Discharge Tube (single)
BSPM1275TN
BSPM1320TN
BSPM1385TN
BSPM1440TN
BSPM1600TN
BSPG1255NPE(R)
1007July 2015
Eaton.com/bussmannseries
14
Ordering information
System voltage/poles
230V/1
Max. continuous operating AC voltage (MCOV) [UC]
275V
Catalog numbers:
Without remote signaling
BSPM1275TN
(Base + modules)
With remote signaling
BSPM1275TNR
Replacement modules
BPM275IEC
230V/1
230V/1
400V/1
600V/1
230V/1*
320V
385V
440V
600V
255V
BSPM1320TN BSPM1385TN BSPM1440TN BSPM1600TN BSPG1255NPE
BSPM1320TNR BSPM1385TNR BSPM1440TNR BSPM1600TNR BSPG1255NPER
BPM320IEC
BPM385IEC
BPM440IEC
BPM600IEC
BPG255NPE
Specifications
TN / TT
350V
<
_ 1.25kV
<
_ 1kV
125A gL/gG
TN / TT
420V
<
_ 1.5kV
<
_ 1.2kV
125A gL/gG
TN / TT
500V
<
_ 1.75kV
<
_ 1.35kV
125A gL/gG
TN
585V
<
_ 2kV
<
_ 1.7kV
125A gL/gG
TN
600V
<
_ 2.5kV
<
_ 2kV
100A gL-gG
TT
-<
_ 1.5kV
---
50kArms
25kArms
25kArms
25kArms
25kA rms
--
335V/5 sec.
<
_ 25 ns
--20kA
40kA
KEMA
335V/5 sec.
<
_ 25 ns
--20kA
40kA
KEMA, CSA
385V/5 sec.
580V/5 sec.
600V/5 sec.
<
_ 25 ns
<
_ 25 ns
<
_ 25 ns
------20kA
20kA
15kA
40kA
40kA
30kA
KEMA, CSA
KEMA, CSA
KEMA, CSA
1 mod., DIN 43880
Type 2
Class II
Withstand
-40C to +80C
Green (good) / red (replace)
1
1.5mm2/14AWG solid/flexible
35mm2/2AWG stranded-25mm2/4AWG flexible
35mm DIN Rail per EN 60715
Thermoplastic, UL 94V0
Indoor
IP20
Five years**
1200V/200 ms
<
_ 100 ns
100Arms
12kA
20kA
40kA
KEMA
Surge protection
devices
Changeover contact
250V/0.1A
250V/0.1A; 125V/0.2A; 75V/0.5A
60/75C Max. 1.5mm2/14AWG Solid/Flexible
Order from catalog numbers above
* N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems.
** See SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
DIN
fuse size
00
0
01
1
02
2
1007July 2015
Eaton.com/bussmannseries
14-33
14
Dimensions - mm
Remote signal
contact available
Description
The Bussmann series IEC Class II 230V, two-pole, modular
surge arresters feature local, easy ID visual indication and
optional remote contact signaling. The unique module locking
system fixes the protection module to the base part. Modules
can be easily replaced without tools by simply depressing the
release buttons. Integrated mechanical coding between the
base and protection module ensures against installing an
incorrect replacement module.230V models are offered with
MCOV ratings of 255 and 275V.
TN system arresters
The features of these single-pole devices are for use in
Single-phase 230V TN systems (2-0 circuit).
TT system arrester
The features of these single-pole devices are for use in
Single-phase 230V TT and TNS systems (1-1 circuit).
Optional remote signaling Form C contact
The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.
Circuit diagrams
MOV
Thermal Disconnector
Gas Discharge Tube (single)
BSPM2275TN
BSPH2275TT
1007July 2015
Eaton.com/bussmannseries
14
Ordering information
System voltage/poles
Max. continuous operating AC voltage (MCOV) [UC]
Max. continuous operating AC voltage (MCOV) [L-N] [UC]
Max. continuous operating AC voltage (MCOV) [N-PE] [UC]
Catalog numbers:
Without remote signaling
With remote signaling
Replacement modules:
MOV Technology
Spark Gap technology
230V/2
275V
--BSPM2275TN
BSPM2275TNR
BPM275IEC
--
230V/2
-275V
255V
BSPH2275TT
BSPH2275TTR
BPM275IEC
BPSNPEIEC*
-<
_ 1.25kV
<
_ 1kV
----<
_ 25 ns
--335V/5 sec.
---
12kA
--<
_ 1.25kV
<
_ 1kV
<
_ 1.5kV
100A rms
-<
_ 25 ns
<
_ 100 ns
-335V/5 sec.
1200V/200 ms
Specifications
Type 2
Class II
20kA
40kA
125A gL/gG
50kA rms
230V
withstand
-40C to +80C
green (good)/red (replace)
1
1.5mm2/14AWG solid/flexible
35mm2/2AWG stranded-25mm2/4AWG flexible
35mm DIN rail per EN 60715
Thermoplastic, UL 94V0
Indoor
IP20
2 mods., DIN 43880
KEMA
Five years**
Surge protection
devices
Changeover contact
250V/0.1A
250V/0.1A; 125V/0.2A; 75V/0.5A
60/75C Max. 1.5mm2/14AWG Solid/Flexible
Order from catalog numbers above
* N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems.
** See SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
1007July 2015
Eaton.com/bussmannseries
14-35
14
BSPM_ _ _ _TNC
Dimensions - mm
Remote signal
contact available
Description
The Bussmann series IEC Class II 120/240V and 230/400V,
three-pole, modular surge arresters feature local, easy ID
visual indication and optional remote contact signaling. The
unique module locking system fixes the protection module to
the base part. Modules can be easily replaced without tools
by simply depressing the release buttons. Integrated
mechanical coding between the base and protection module
ensures against installing an incorrect replacement module.
120V models are offered with a MCOV rating of 150V.
230V models are offered with a MCOV rating of 275 or 385V.
TNC system arresters
The features of these three-pole devices are for use in TN-C
120/240V or 230/400V systems (3-0 circuit) against surges.
Optional remote signaling Form C contact
The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.
Circuit diagrams
MOV
Thermal Disconnector
1007July 2015
Eaton.com/bussmannseries
14
Ordering information
System voltage/poles
Max. continuous operating AC voltage (MCOV) [UC]
Catalog numbers:
Without remote signaling
With remote signaling
Replacement module
MOV technology
120V/3
150V
BSPM3150TNC
BSPM3150TNCR
BPM150IEC
230V/3
275V
BSPM3275TNC
BSPM3275TNCR
BPM275IEC
230V/3
385V
BSPM3385TNC
BSPM3385TNCR
BPM385IEC
Specifications
Nominal AC voltage [UN]
Voltage protection level [UP]
Voltage protection level at 5kA [UP]
Short-circuit withstand capability for max. mains-side overcurrent protection
Temporary overvoltage (TOV) [UT]
Nominal discharge current (8/20 s) [In]
Max. discharge current (8/20 s) [Imax]
SPD according to EN 61643-11
SPD according to IEC 61643-1
Response time [tA]
Max. mains-side overcurrent protection
TOV characteristics
Operating temperature range [TU]
Operating state/fault indication
Number of ports
Cross-sectional area (min.)
Cross-sectional area (max.)
Mounting
Enclosure material
Location category
Degree of protection
Capacity
Agency Information
Product warranty
120/240V
<
_ 0.7kV
<
_ 0.55kV
50kArms
175V/5 sec
15kA
230/400V
230/400V
<
_ 1.25kV
<
_ 1.75kV
<
_ 1kV
<
_ 1.35kV
50kArms
25kArms
335V/5 sec.
385V/5 sec
20kA
20kA
40kA
Type 2
Class II
<
_ 25 ns
125A gL/gG
withstand
-40C to +80C
Green (good)/red (replace)
1
1.5mm2/14AWG solid/flexible
35mm2/2AWG stranded-25mm2/4AWG flexible
35mm DIN rail per EN 60715
Thermoplastic, UL 94V0
Indoor
IP20
3 mods., DIN 43880
KEMA
Five years*
Surge protection
devices
1007July 2015
Eaton.com/bussmannseries
14-37
14
BSPH_TNS, BSPH_TT
Dimensions - mm
MOV
Circuit diagrams
Remote signal
contact available
Thermal Disconnector
Gas Discharge Tube (single)
Description
The Bussmann series IEC Class II 230/400V, four-pole,
modular surge arresters feature local, easy ID visual
indication and optional remote contact signaling. The unique
module locking system fixes the protection module to the
base part. Modules can be easily replaced without tools by
simply depressing the release buttons. Integrated mechanical
coding between the base and protection module ensures
against installing an incorrect replacement module.
These 230V models are offered with MCOV ratings of 275,
320 or 385V.
TNS system arrester
The features of these four-pole devices are for use in TNS
230/400V systems (4-0 circuit) against surges.
TT system arrester
The features of these four-pole devices are for use in TT and
TN-S 230/400V systems (3+1 circuit) against surges.
Optional remote signaling Form C contact
The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.
BSPM4275TNS
Shown with optional remote contact signaling
BSPH4275TT, BSPH4320TT
BSPH4385TT
Shown with optional remote contact signaling
For remote signaling contact, add R suffix to the part number,
E.g., BSPH4275TTR
Data Sheet: 1169
14-38
1007July 2015
Eaton.com/bussmannseries
14
Ordering information
System voltage/poles
Max. continuous operating AC voltage (MCOV) [UC]
Max. continuous operating AC voltage (MCOV) [L-N] [UC]
Max. continuous operating AC voltage [N-PE] [UC]
Catalog numbers:
Without remote signaling
With remote signaling
Replacement modules:
MOV technology
Spark Gap technology
230V/4
275V
--BSPM4275TNS
BSPM4275TNSR
BPM275IEC
--
230V/4
230V/4
230V/4
---275V
320V
385V
255V
255V
255V
BSPH4275TT BSPH4320TT BSPH4385TT
BSPH4275TTR BSPH4320TTR BSPH4385TTR
BPM275IEC
BPM320IEC
BPM385IEC
BPSNPEIEC*
BPSNPEIEC*
BPSNPEIEC*
-<
_ 1.25kV
<
_ 1kV
----<
_ 25 ns
--335V/5 sec.
---
12kA
12kA
12kA
------<
_ 1.25kV
<
_ 1.5kV
<
_ 1.75kV
<
_ 1kV
<
_ 1.2kV
<
_ 1.35kV
<
_ 1.5kV
<
_ 1.5kV
<
_ 1.5kV
100Arms
100Arms
100Arms
---<
_ 25 ns
<
_ 25 ns
<
_ 25 ns
<
_ 100 ns
<
_ 100 ns
<
_ 100 ns
---335V/5 sec.
335V/5 sec.
385V/5 sec.
1200V/200 ms 1200V/200 ms 1200V/200 ms
Specifications
Lightning impulse current (10/350 s) [N-PE] [Iimp]
Voltage protection level [UP]
Voltage protection level at 5kA [UP]
Voltage protection level [L-N] [UP]
Voltage protection level [L-N] at 5kA [UP]
Voltage protection level [N-PE] [UP]
Follow current extinguishing capability [N-PE] [Ifi]
Response time [tA]
Response time [L-N] [tA]
Response time [N-PE] [tA]
Temporary overvoltage (TOV) [UT]
Temporary overvoltage (TOV) [L-N] [UT]
Temporary overvoltage (TOV) [N-PE] [UT]
Short-circuit withstand capability for max.
mains-side overcurrent protection
SPD according to EN 61643-11
SPD according to IEC 61643-1
Nominal AC voltage [UN]
Nominal discharge current (8/20 s) [In]
Max. discharge current (8/20 s) [Imax]
Max. mains-side overcurrent protection
TOV characteristics
Operating temperature range [TU]
Operating state/fault indication
Number of ports
Cross-sectional area (min.)
Cross-sectional area (max.)
Mounting
Enclosure material
Location category
Degree of protection
Capacity
Agency Information
Product warranty
50kArms
50kArms
25kArms
25kArms
Surge protection
devices
Type 2
Class II
230/400V
20kA
40kA
125A gL/gG
withstand
-40C to +80C
green (good)/red (replace)
1
1.5mm2/14AWG solid/flexible
35mm2/2AWG stranded-25mm2/4AWG flexible
35mm DIN rail per EN 60715
Thermoplastic, UL 94V0
Indoor
IP20
4 mods., DIN 43880
KEMA
Five years**
Changeover contact
250V/0.1A
250V/0.1A; 125V/0.2A; 75V/0.5A
60/75C Max. 1.5mm2/14AWG Solid/Flexible
Order from catalog numbers above
* N-PE Surge arrester module for location between neutral conductor and protective conductor in TT systems.
** See SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
1007July 2015
Eaton.com/bussmannseries
14-39
14
PV SPDs 600/1000/1200Vdc
overvoltage
1000Vdc lightning arrester
Description:
600, 1000Vdc
PV HEAVY DUTY
(Safety)
Bi-pole
Integrated overcurrent
protection for complete
device isolation and
enhanced safety
Catalog numbers:
PV PRO (Base + three modules) bi-pole systems
W/O remote signaling
BSPP3600YPV
600Vdc
With remote signaling
BSPP3600YPVR
Replacement module
BPP300SYPV
W/O remote signaling
BSPP31000YPV
1000Vdc
With remote signaling
BSPP31000YPVR
Replacement module
BPP500SYPV
PV HEAVY DUTY (Base + three modules) bi-pole systems
W/O remote signaling
BSPH3600YPV
600Vdc
With remote signaling
BSPH3600YPVR
Outer (2) BPH300YPV
Replacement modules:
Center
BPM300YPV
W/O remote signaling
BSPH31000YPV
1000Vdc
With remote signaling
BSPH31000YPVR
Outer (2) BPH500YPV
Replacement modules:
Center (1) BPM500YPV
W/O remote signaling
BSPH31200YPV
1200Vdc
With remote signaling
BSPP31200YPVR
Outer (2) BPH600YPV
Replacement modules:
Center (1) BPM600YPV
PV HEAVY DUTY (Base + two modules) mono-pole systems
W/O remote signaling
BSPH2600PV
600Vdc
With remote signaling
BSPH2600PVR
Left
BPH300YPV
Replacement modules:
Right
BPM300YPV
PV ADVANCE (Complete assembly)
1000Vdc
BSPS31000PV (complete assembly)
Product specifications
Nominal system voltage Vo
System type
PV PRO
600, 1000Vdc
Bi-pole
Protection from
Wiring configuration / applications
PV HEAVY DUTY
600, 1000, 1200Vdc
Mono-pole, bi-pole
Surge
Surge
I and Y configuration
Applications B, C and D
20kA
20kA
40kA
125A
MOV
UL Recognized,
EN 50539-11
2 Years
Combiner
boxes
I and Y configuration
Applications B, C, D and E
12.5kA
10kA
25kA
1000A
MOV SCI
UL Recognized,
EN 50539-11
5 Years
Recombiner boxes /
inverters
14-40
1007July 2015
Eaton.com/bussmannseries
PV ADVANCE
Up to 1000Vdc
Bi-pole
Direct/Indirect
Lightning Currents
Application A
100kA
50kA
N/A
14
PV PRO Performance
rd
Fast-Acting Fuse
DC/+
MOV
12
11
14
MOV
Thermal Disconnector
DC+/
Thermal Disconnector
12
11
14
DC/+
BSPP_____YPV*
Shown with optional remote contact signaling
BSPH2600PV*
BSPH_____YPV*
DC +
Surge protection
devices
1007July 2015
Eaton.com/bussmannseries
14-41
14
PV ADVANCE Lightning
Class I SPD per IEC 61643-11
standards for PV systems up to
1000V DC.
Common
Equipment
Grounding
Conductor
PV PRO
PV HEAVY DUTY
PV wiring applications
Common
Equipment
Grounding
Conductor
PV PRO
PV HEAVY DUTY
BSPS31000PVP
Equipment
Grounding
Conductor
PV PRO
14-42
PV HEAVY DUTY
PV HEAVY DUTY
1007July 2015
* BSPP31200YPV(R) only.
** BSPP31000YPV(R) 1000Vdc one energized pole/mode requires the
following:
1. Use a suitable electrical insulator to keep a 10mm min. safety
distance from the PV-SPD and other grounded parts in the housing.
2. No metal covers are permitted in the area of the module release
button.
Eaton.com/bussmannseries
14
Ordering information
Nominal PV system voltage
Catalog numbers:
(Base + modules)
Replacement modules:
600Vdc
BSPH2600PV
BSPH2600PVR
BPH300YPV
BPM300YPV
Specifications
Conformity with prEN 50539-11
SPD Classification per EN 61643-11
SPD Classification per IEC 61643-1
Max. PV voltage [UCPV]
Short-circuit withstand capacity [ISCWPV]
MCOV [UCPV]
Nominal discharge current (8/20 s) [(DC+/DC-) --> PE] [In]
Max. discharge current (8/20 s) [(DC+/DC-) --> PE] [Imax]
Voltage protection level [UP]
Voltage protection level at 5kA [UP]
Response time [tA]
Operating temperature range [TU]
Operating state/fault indication
Number of ports
Cross-sectional area (min.)
Cross-sectional area (max.)
For mounting on
Enclosure material
Place of installation
Degree of protection
Capacity
Agency Information:
UL
IEC
Product warranty
Yes
Type 2
Class II
<
_ 600V
1000A
700Vdc
12.5kA
25kA
<
_ 2.5kV
<
_ 2kV
<
_ 25 ns
-40C to +80C
Green (good) / red (replace)
1
60/75C 1.5mm2/14AWG Solid/Flexible
60/75C 35mm2/2AWG Stranded/25mm2/4AWG Flexible
35 mm DIN rail per EN 60715
Thermoplastic, UL 94V0
Indoor
IP20
2 Modules, DIN 43880
UL 1449 3rd Edition (Type 1) CA
IEC 61643-11 Type 2, IEC 61643-1 Class II
Five years*
Surge protection
devices
* See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
1007July 2015
Eaton.com/bussmannseries
14-43
14
BSPS_ _ _ _WE
Dimensions - mm
Remote signal
contact available
Shown with optional remote contact signaling
Description
The Bussmann series IEC Class I 400 and 690V, one-pole
lightning current arresters feature local, easy ID visual
indication and optional remote contact signaling.
440V and 760V maximum continuous operating voltage
arresters protect installations against surges and direct
lightning strikes.
System and application
TNC 400V/690V: 3x BSPS1400WE(R)
TNS 400/690V: 4x BSPS1400WE(R)
IT 690V: 3x BSPS1690WER
Optional remote signaling Form C contact
The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.
Circuit diagrams
BSPS1400WE
BSPS1690WE
Shown with optional remote contact signaling
1007July 2015
Eaton.com/bussmannseries
14
Ordering information
System voltage/poles
Max. continuous Operating AC voltage (MCOV) [UC]
Catalog numbers:
Without remote signaling
With remote signaling
400V/1
440V
BSPS1400WE
BSPS1400WER
690V/1
760V
-BSPS1690WER
Specifications
Line system type
Lightning impulse current (10/350 s) [Iimp]
Specific energy [W/R]
Nominal discharge current (8/20 s) [In]
Voltage protection level [UP]
Follow Current Extinguishing Capability AC [Ifi]
Follow Current Limitation / Selectivity
TNC, TNS, IT
25kA
156.25kJ/ohms
25kA
<
_ 4kV
25kArms
no tripping of a 32 A gL/gG
fuse up to 25 kArms (prosp.)
<
_ 100 ns
250A gL/gG
100A gL/gG
---125A gL/gG
50kArms
25kArms
690V / 5 sec.
1000V / 5 sec.
-10mm2 solid/flexible
2
10mm solid/flexible
-50mm2/1AWG stranded/35mm2/2AWG flexible
-2
-50mm /1AWG stranded/35 mm2/2AWG flexible
35mm2/2AWG stranded/25mm2/4AWG flexible
35mm2/2AWG stranded/25mm2/4AWG flexible
Type 1
Class I
Withstand
-40C to +80C
-40C to +60C
Green (good) / red (replace)
1
35mm DIN rail per EN 60715
Thermoplastic, UL 94V0
Indoor
IP20
2 Mods., DIN 43880
Five years*
Changeover contact
250V/0.5A
250V/0.1A; 125V/0.2A; 75V/0.5A
60/75C Max. 1.5mm2/
14AWG Solid/Flexible
Order from catalog numbers above
* See SPD Limited Warranty Statement (3A1502) for details at
www.cooperbussmann.com/surge.
1007July 2015
Eaton.com/bussmannseries
14-45
Surge protection
devices
TNC, TNS, IT
35kA
306.25kJ/ohms
35kA
<
_ 2.5kV
50kArms
no tripping of a 32 A gL/gG
fuse up to 50 kArms (prosp.)
<
_ 100 ns
--500A gL/gG
250A gL/gG
160A gL/gG
125A gL/gG
14
Dimensions - mm
Shown with
optional remote
contact signaling
Remote Signal
Contact Available
Description
The Bussmann series IEC Class II 75, 230, 400, 690 and 1000V,
one-pole, modular surge arresters feature local, easy ID visual
indication and optional remote contact signaling. The unique module
locking system on the 75 to 690V arresters fixes the protection
module to the base part. Modules can be easily replaced without
tools by simply depressing the release buttons. Integrated
mechanical coding between the base and protection module ensures
against installing an incorrect replacement module.
TN system arresters (also 1-phase TT systems)
The features of these single-pole devices are for use as a single
device or in combination with other devices.
TT system arrester
1000V Arrester
BSPM175WE
BSPM1400WE
BSPM1690WE
MOV
BSPG1230WE
Thermal Disconnector
BSPM11000WE
1007July 2015
Eaton.com/bussmannseries
14
Ordering information
System voltage/poles
Max. continuous operating AC voltage (MCOV) [UC]
Catalog numbers:
Without remote signaling
(Base + modules)
With remote signaling
Replacement modules
75V/1
75V
BSPM175WE
BSPM175WER
BPM75WE
TN / TT
100V
-10kA
40kA
--<
_ 0.4kV
<
_ 0.35kV
<
_ 25 ns
125A gL/gG
50kArms
230V/1
255V
BSPG1230WE
BSPG1230WER
BPG255NPEWE*
400V/1
440V
BSPM1400WE
BSPM1400WER
BPM440WE
690V/1
600V
BSPM1690WE
BSPM1690WER
BPM750WE
1000V/1
1000V
BSPM11000WE
BSPM11000WER
N/A
TT
--20kA
40kA
100 Arms
12kA
<
_ 1.5kV
-<
_ 100 ns
--
TN / TT
585
-20kA
40kA
--<
_ 2.0kV
<
_ 1.7kV
<
_ 25 ns
125A gL/gG
TN / TT
600V
750V
15kA
25kA
--<
_ 3kV
<
_ 2.5kV
<
_ 25 ns
100A gL/gG
TN / TT
1000V
1000V
15kA
30kA
--<
_ 4.2kV
<
_ 3.5kV
<
_ 25 ns
100A aM**
--
25kArms
25kArms
25kArms
Specifications
1000V / 5 sec.
2 Mod., DIN 43880
Surge protection
devices
90V / 5 sec.
1200V / 200ms
580V / 5 sec.
900V / 5 sec.
1 Mod., DIN 43880 1 Mod., DIN 43880 1 Mod., DIN 43880 1 Mod., DIN 43880
Type 2
Class II
Withstand
-40C to +80C
Green (good) / red (replace)
1
1.5mm2/14AWG solid/flexible
35mm2/2AWG stranded-25mm2/4AWG flexible
35mm DIN rail per EN 60715
Thermoplastic, UL 94V0
Indoor
IP20
CSA Std C22.2 No.8-M1986
KEMA to EN 61643-11
Five years***
Changeover contact
250V/0.5A
250V/0.1A; 125V/0.2A; 75V/0.5A
60/75C Max. 1.5mm2/14AWG Solid/Flexible
Order from catalog numbers above
* N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems.
** 125A gL/gG @ 690Vac.
*** See SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
1007July 2015
Eaton.com/bussmannseries
14-47
14
Dimensions - mm
Remote signal
Contact available
BSPM2230WE
MOV
BSPH2230WE
Gas Discharge Tube (single)
Thermal Disconnector
1007July 2015
Eaton.com/bussmannseries
14
Ordering information
System voltage/poles
Max. continuous operating AC voltage (MCOV) [UC]
Catalog numbers:
Without remote signaling
(Base + modules)
With remote signaling
Replacement modules
MOV
Spark Gap
230V/2
275V
BSPM2230WE
BSPM2230WER
BPM275WE
--
230V/2
275 / 255V
BSPH2230WE
BSPH2230WER
BPM275WE
BPSNPEWE*
TN
--20kA
40kA
-<
_ 1.25kV
<
_ 1kV
------<
_ 25 ns
125A gL/gG
50kArms
335 V / 5 sec.
---
TT
275V
255V
20kA
40kA
12kA
--<
_ 1.25kV
<
_ 1kV
<
_ 1.5kV
100Arms
<
_ 25 ns
<
_ 100 ns
-125A gL/gG
50kArms
-335V / 5 sec.
1200V / 200 ms
Specifications
Type 2
Class II
Withstand
-40C to +80C
Green (good) / red (replace)
1
1.5mm2/14AWG solid/flexible
35mm2/2AWG stranded-25mm2/4AWG flexible
35mm DIN rail per EN 60715
Thermoplastic, UL 94V0
Indoor
IP20
2 Mods., DIN 43880
KEMA to EN 61643-11
Five years**
Surge protection
devices
Changeover contact
250V/0.5A
250V/0.1A; 125V/0.2A; 75V/0.5A
60/75C Max. 1.5mm2/
14AWG Solid/Flexible
Order from catalog numbers above
* N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems.
** See SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
1007July 2015
Eaton.com/bussmannseries
14-49
14
BSPM_ _ _ _WE
Dimensions - mm
Remote Signal
Contact Available
Specifications
Description
The Bussmann series IEC Class II 230, 400 and 690V threepole, modular surge arresters feature local, easy ID visual
indication and optional remote contact signaling. The unique
module locking system fixes the protection module to the
base part. Modules can be easily replaced without tools by
simply depressing the release buttons. Integrated mechanical
coding between the base and protection module ensures
against installing an incorrect replacement module.
TNC system arresters
The features of these three-pole devices are for use as a
single device.
Optional remote signaling Form C contact
The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.
BSPM3230WE
BSPM3400WE
BSPM3690WE
MOV
Thermal Disconnector
1007July 2015
Eaton.com/bussmannseries
14
Ordering information
System voltage/poles
Max. continuous operating AC voltage (MCOV) [UC]
Catalog numbers:
Without remote signaling
(Base + modules)
With remote signaling
Replacement modules
230V/3
275V
BSPM3230WE
BSPM3230WER
BPM275WE
400V/3
440V
BSPM3400WE
BSPM3400WER
BPM440WE
690V/3
600V
BSPM3690WE
BSPM3690WER
BPM750WE
Specifications
TNC
230/400V
275V
20kA
40kA
<
_1.25kV
<
_1kV
<
_25 ns
125A gL/gG
50kArms
335V / 5 sec.
TNC
TNC
400/690V
600V
440V
750V
20kA
15kA
40kA
25kA
<
_ 2kV
<
_3kV
<
_ 1.7kV
<
_2.5kV
<
_ 25 ns
<
_25 ns
125A gL/gG
100A gL/gG
25kArms
25kArms
580V / 5 sec.
900V / 5 sec.
Type 2
Class II
Withstand
-40C to +80C
Green (good) / red (replace)
1
1.5mm2/14AWG solid/flexible
35mm2/2AWG stranded-25mm2/4AWG flexible
35mm DIN rail per EN 60715
Thermoplastic, UL 94V0
Indoor
IP20
3 Mods., DIN 43880
KEMA to EN 61643-11
Five years*
Surge protection
devices
Changeover contact
250V/0.5A
250V/0.1A; 125V/0.2A; 75V/0.5A
60/75C Max. 1.5mm2/14AWG Solid/Flexible
Order from catalog numbers above
1007July 2015
Eaton.com/bussmannseries
14-51
14
Dimensions - mm
Remote signal
contact available
Shown with optional remote contact signaling
Specifications
Description
The Bussmann series IEC Class II 230/400V, four-pole,
modular surge arresters feature local, easy ID visual
indication and optional remote contact signaling. The unique
module locking system fixes the protection module to the
base part. Modules can be easily replaced without tools by
simply depressing the release buttons. Integrated mechanical
coding between the base and protection module ensures
against installing an incorrect replacement module.
These 230V models are offered with MCOV ratings of 275V.
TNS system arrester
The features of these four-pole devices are for use in TNS
230/400V systems (4-0 circuit) against surges.
TT system arrester
The features of these four-pole devices are for use in TT and
TN-S 230/400V systems (3+1 circuit) against surges.
Optional remote signaling Form C contact
The three-pole terminal remote signaling contact versions
have a floating changeover contact for use as a break or
make contact, according to circuit concept.
Circuit diagrams
BSPM4230WE
MOV
Thermal Disconnector
Gas Discharge Tube (single)
BSPH4230WE
Shown with optional remote contact signaling
For remote signaling contact, add R suffix to the part number,
E.g., BSPM4230WER
1007July 2015
Eaton.com/bussmannseries
14
Ordering information
System voltage/poles
Max. continuous operating AC voltage (MCOV) [UC]
Max. continuous operating AC voltage (MCOV) [L-N] [UC]
Max. continuous operating AC voltage [N-PE] [UC]
Catalog numbers:
Without remote signaling
With remote signaling
Replacement modules:
MOV technology
Spark Gap technology
230/400V/4
275V
--BSPM4230WE
BSPM4230WER
BPM275WE
--
230/400V/4
-275V
255V
BSPH4230WE
BSPH4230WER
BPM275WE
BPSNPEWE*
TNS
230/400V
-<
_ 1.25kV
<
_ 1kV
----<
_ 25 ns
--335V / 5 sec.
---
TT / TNS
230/400V
12kA
--<
_ 1.25kV
<
_ 1kV
<
_ 1.5kV
100Arms
-<
_ 25 ns
<
_ 100 ns
-335V / 5 sec.
1200V / 200 ms
Specifications
Type 2
Class II
20kA
40kA
125A gL/gG
50kA rms
withstand
-40C to +80C
green (good)/red (replace)
1
1.5mm2/14AWG solid/flexible
35mm2/2AWG stranded-25mm2/4AWG flexible
35mm DIN rail per EN 60715
Thermoplastic, UL 94V0
Indoor
IP20
4 Mods., DIN 43880
KEMA to EN 61643-11
Five years**
Surge protection
devices
Changeover contact
250V/0.1A
250V/0.1A; 125V/0.2A; 75V/0.5A
60/75C Max. 1.5mm2/14AWG Solid/Flexible
Order from catalog numbers above
* N-PE Surge arrester module for location between neutral conductor and protective conductor in TT systems.
** See SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge.
1007July 2015
Eaton.com/bussmannseries
14-53
14
BSPD5BNCDD
BSPD5BNCDI
Protected
side
Dimensions-mm
19.00
Direct shield
BSPD5BNCDD
12.70
Protected
side
100.08
Indirect shield
BSPD5BNCDI
35.50
14-54
1007July 2015
Decoupling Resistor
Eaton.com/bussmannseries
14
Technical data
Catalog number
BSPD5BNCDD
BSPD5BNCDI
5V
6.4V
0.1A
10kA
5kA
35V
13V
0-300MHz
20pF
650V
600V
50
75
50
75
0.4dB
160MHz
80MHz
160MHz
80MHz
3dB
300MHz
300MHz
300MHz
300MHz
10dB
200MHz
100MHz
300MHz
100MHz
20dB
130MHz
30MHz
130MHz
30MHz
4.7
25pF
-40C to +80C
Degree of protection
IP10
Mounting
Grounding
Enclosure material
Color
Bare surface
Test standards
Warranty
Surge protection
devices
Agency information
Five years*
Cam
Video
system
BSPD5BNCDD
BSPD5BNCDI
Melsec Net 2
N1 LAN
Data networks
Arcnet
era
protected
side
coaxial cable
BSPD5BNCDD
Direct Shield SPD
protected
side
BSPD5BNCDI
Indirect Shield SPD
Video systems
Video (coax)
See document 3A1977 for DIN-Rail BNC coaxial cable SPD installation instructions.
52
www.bussmann.com
1007July 2015
Eaton.com/bussmannseries
14-55
14
BSPD5BNCSI
300.00 APPROX
24.00
74.00
14-56
1007July 2015
Decoupling Resistor
Capacitor
Eaton.com/bussmannseries
14
UL
497B data signal
SPDs
Application
note
for North American
Technical data
Catalog number
BSPD5BNCSI
5V
8V
2.5kA
10kA
25V
15V
600V
50
75
300MHz
265MHz
40MHz
40MHz
10
50pF
-40C to +80C
BNC Socket (female) /
BNC Plug (male)
Shield grounding
Test standards
Agency information
UL 497B
Warranty
Five years*
Surge protection
devices
BSPD5BNCSI
Melsec Net 2
X
Data networks
Arcnet
X
Video systems
Video (coax)
See document 3A1978 for in-line BNC coaxial cable SPD installation instructions.
54
www.bussmann.com
1007July 2015
Eaton.com/bussmannseries
14-57
14
BSPD48RJ45
19.00
11.72
76.91
36.15
14-58
1007July 2015
Balanced Gas
Discharge Tube
Inductor
Eaton.com/bussmannseries
14
Application
note
for North American
UL
497B data signal
SPDs
UL power and control, and data signal surge protective devices
Technical data
Catalog number
BSPD48RJ45
48V
48V
34V
57V
1A
150A
2.5kA
10kA
150A
190V
600V
600V
180V
500V
600V
BSPD48RJ45
X
Data networks
ATM
Ethernet 10/100/1000
FDDI, CDDI
Industrial Ethernet
3dB
Token Ring
30pF
VG any LAN
25pF
Degree of protection
Mounting
-40C to +80C
Video (2 wire)
Surge protection
devices
X
Video systems
X
IP10
35mm DIN-Rail per EN 60715
Pinning
Grounding
Enclosure material
Color
Test standards
Agency information
Warranty
UL 497B
Five years*
See document 3A1979 for RJ45 connector SPD for Ethernet cable installation instructions.
56
www.bussmann.com
1007July 2015
Eaton.com/bussmannseries
14-59
14
US
Description
The Bussmann series universal four-pole, DIN-Rail mounted surge
arresters provide effective protection with minimum space
requirements and are designed for stringent requirements on the
availability of measuring and control circuits, and bus systems.
BSPD5DING
BSPD12DING
BSPD24DING
BSPD48DING
BSPD5DINLHF
BSPD24DINLHF
BSPD24DING
BSPD24DINLHF
Circuit diagrams
UL 497B Listed
Function-optimized design for safe use and easy installation
Four-pole and base mounts on grounded 35mm DIN-Rail
Module removal without signal interruption via make-beforebreak circuitry
0-180V BSPD0180DINL automatically adjusts to system
operating voltage and can protect data circuits of different
voltages up to 100mA load current.
Dimensions-mm
71.99
12.00
50.49
35.51
BSPD5DING
BSPD12DING
BSPD24DING
BSPD48DING
16.09
BSPD5DINLHF
BSPD24DINLHF
1
Balanced Gas
Discharge Tube
90.00
3.97
49.99
14-60
U>UN
1007July 2015
Eaton.com/bussmannseries
U>UN
BSPD0180DINL
Thyristor
6.70
U>UN
Decoupling Resistor
45.00
Protected
Surge Detection
Protected
BSPD12DING
BSPD5DINLHF
Protected
BSPD5DING
BSPD48DING
BSPD0180DINL
14
Technical data
Catalog number (Prefix BSPD)
5DING
12DING
24DING
48DING
5DINLHF
24DINLHF
0180DINL
5V
12V
24V
48V
5V
24V
0-180V
6V
15V
33V
54V
6V
33V
180V
4.2V
10.6V
23.3V
38.1V
4.2V
23.3V
127V
1.0A
0.75A
0.75A
0.75A
1.0A
1.0A
0.1A@80C
UN + 53V
29V
50V
102V
160V
25V
65V
27V
37V
66V
95V
550V
550V
18V
38V
90V
140V
11V
47V
see Note 1
9V
19V
45V
70V
550V
550V
see Note 2
550V
10kA
10kA
10kA
10kA
10kA
10kA
10kA
2.5kA
2.5kA
2.5kA
2.5kA
2.5kA
2.5kA
2.5kA
20kA
20kA
20kA
20kA
20kA
20kA
20kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
1.0
1.8
1.8
1.8
1.0
1.0
10/7.5 typ
0-400Hz
5V
100mA
1.0MHz
2.7MHz
6.8MHz
8.7MHz
100MHz
100MHz
50MHz
2.7nF
1.0nF
0.5nF
0.35nF
25pF
25pF
80pF
5.4nF
2.0nF
1.0nF
0.7nF
16pF
16pF
16pF
ATEX approvals
Agency information
D1, C2, C3
-40C to +80C
Surge protection
devices
Degree of protection
IP20
For mounting on
Grounding
Test standards
Screw terminal
Solid
12-28AWG
Flexible
14-28AWG
Terminal torque
3.5 Lb-In
Warranty
Five years*
max. [V]
When a surge occurs, the SPD voltage protection level adjusts itself
based upon the output terminal operating voltage of the base.
C2
C3
Un
200 V
175 V
150 V
125 V
100 V
75 V
50 V
25 V
UN
0V
20 V
40 V
60 V
80 V
100 V 120 V
UN (Operating Voltage)
For installation instructions, see document 3A1980 (5-48V) and 3A1981 (0-180V).
48
www.bussmann.com
1007July 2015
Eaton.com/bussmannseries
14-61
14
BSPD5DING
X
X
X
X
14-62
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Telecommunication, telephony
X
X
X
X
X
X
X
X
X
X
Data networks
V 24 (RS232 C)
BSPD0180DINL
1007July 2015
Eaton.com/bussmannseries
14
SurgePOD modules
Standard SurgePOD
SurgePOD Module
Standard
module Catalog
catalogNumber
number System
system
SPOD
320
Series
MCOV
SPOD = Standard
Terminal
Location
150
270
320
420
550
Optional visual
indicator tab
T = yes
Blank = none
Terminal length
S = short (5.6mm)
L = long (16.8mm)
Catalog symbols
SPOD (Standard module)
SPODU (Universal module)
Ratings
See ratings table
Agency information
UL Recognized, 1449 3rd Edition Type 1 Component
Assembly Device; E340782
Flammability rating
UL 94V0
Terminal material
Nickel-plated copper
Storage and operating temperature range
-25C to +85C
Traceability
Each SurgePOD SPD module is marked with a serial number
for identification and tracking
Options
Remote contact signaling is accomplished with a Normally
Open (NO) microswitch that closes upon the module
reaching an overvoltage breakdown condition.
Local visual indication is accomplished with indicating tabs
that protrude through the devices top upon the module
reaching an overvoltage breakdown condition.
Packaging
200 units per master pack
Additional information
The SurgePOD module may be damaged by excessive
mechanical shock or rough handling. To ensure integrity of
finished device, do NOT install any SurgePOD module that
was dropped or abused during assembly.
Suitability for final application of a SurgePOD module to be
determined by the OEM.
Pb
Universal
SurgePOD
Module
Catalog
Number
Systemsystem
Universal
SurgePOD
module
catalog
number
SPODU
320
Optional visual
indicator tab
MCOV
Series
SPODU = Universal
terminal
location
Optional remote
contact signaling
150
270
320
420
550
2
Enclosure Height
T = yes
Blank = none
Terminal length
M = mini (3.4mm)
S = short (5.6mm)
2 = tall
Blank = short
Optional remote
contact signaling
R = yes (normally open)
Blank = none
1007July 2015
Eaton.com/bussmannseries
14-63
Surge protection
devices
Description
Bussmann Standard and
Universal SurgePOD modules
are PCB-mountable for original
equipment applications.
Universal modules are primarily
differentiated from the Standard
modules by having consistent
terminal spacing dimensions on
all Maximum Continuous
Operating Voltage (MCOV)
ratings.
This consistent terminal spacing eliminates the need for
OEMs to maintain multiple PCB designs.
Standard modules have two available terminal lengths and
spacing dimensions vary by MCOV rating (see Standard
module dimensions for details).
When a surge condition exceeds either the Standard or
Universal SPD modules MCOV, the patented Metal Oxide
Varistor (MOV) technology becomes conductive to safely
shunt the surge to ground.
The same MOV technology also eliminates the need for
additional fusing in UL applications by safely disconnecting
the SPD module upon reaching an overvoltage breakdown
condition.
All Standard or Universal SPD modules are UL Recognized
1449 3rd Edition for installation in Type 1 or Type 2 surge
protective devices.
Optional remote contact signaling is accomplished with a
Normally Open (NO) microswitch that closes upon the
module reaching an overvoltage breakdown condition.
Optional local visual indication is accomplished with
indicating tabs that protrude through the devices top upon
the module reaching an overvoltage breakdown condition.
14
SurgePOD modules
Specifications for SurgePOD Standard and Universal Modules
Color Code
Blue
Green
Yellow
150V
270V
320V
Maximum Continuous Operating Voltage MCOV (Vrms)
120V
220V
277V
Nominal system voltage @ 50/60Hz (Vrms)
20kA
20kA
20kA
Nominal discharge current rating 8/20s (In)
50kA
50kA
50kA
Max discharge current rating 8/20s (Imax)
Short-Circuit Current Rating (SCCR)
200kA
200kA
200kA
600V
900V
1200V
Voltage Protection Rating (Vpr)
Red
420V
347V
20kA
50kA
200kA
1500V
Brown
550V
480V
20kA
50kA
200kA
1500V
1.700 0.005
[43.08 0.13]
1.700 0.005
[43.08 0.13]
0.2380.039
6.041.00
0.2380.039
6.041.00
0.9570.025
24.300.64
0.9550.025
24.250.64
MIN 0.236
6.00
0.7320.025
18.600.64
MIN 0.236
6.00
MIN 0.100
[2.54]
0.7300.025
18.550.64
MIN 0.100
2.54
1.684
42.77
1.684
42.77
*
1.7280.005
43.890.13
**
0.1350.015
3.430.38
0.2800.005
7.110.13
0.667
16.94
Long
Terminals
0.280
7.11
0.6270.010
15.920.25
0.280
7.11
1.2800.012
32.510.30
0.5120.015
13.000.38
0.1120.020
2.840.51
0.2800.005
7.110.13
1.2800.012
32.510.30
0.627 .005
[15.93 0.13]
DIM "A"
0.0570.025
1.450.63
Short
Terminals
0.220.05
5.581.27
0.280
7.11
0.507
12.87
0.280
7.11
DIM "A"
0.133
3.37
0.068
1.71
1007July 2015
Eaton.com/bussmannseries
15
Contents
Description
Page
Accessories
1007July 2015
Eaton.com/bussmannseries
15-1
15
Organization
Accessories
Supplemental
Branch circuit
(5) GMA-500mA
(5) MDL-6
(5) GMA-1A
(5) MDL-7
(5) GMA-2A
(5) MDL-8
(5) GMA-3A
(5) MDL-10
(5) GMA-4A
(5) MDL-15
(5) GMA-5A
(5) MDL-20
(5) GMA-6A
(5) AGC-14
(5) GMA-10A
(5) AGC-12
(5) GMA-15A
(5) AGC-1
(5) AGC-112
(5) MDL-14
(5) MDL-12
(5) AGC-2
(5) MDL-1
(5) AGC-212
1
(5) AGC-3
(5) MDL-1 2
(5) MDL-2
(5) AGC-4
1
(5) MDL-2 2
(5) AGC-5
(5) MDL-3
(5) AGC-6
(5) MDL-4
(5) AGC-7
(5) MDL-5
(5) AGC-8
(1) FT-3 Fuse tester/puller
(1) 6-inch Crescent wire stripper
(5) AGC-10
(5) AGC-15
(5) AGC-20
(5) GMC-2A
(5) GMC-5A
(5) GMC-10A
(5) MDA-5
(5) MDA-10
(5) MDA-12
(5) MDA-15
(5) MDA-20
(5) ABC-5
(5) ABC-10
(5) ABC-12
(5) ABC-15
(5) ABC-20
LP-CC-5
(3) KTK-R-15
LP-CC-10
(3) KTK-R-20
LP-CC-15
(3) KTK-R-30
LP-CC-20
(3) FNQ-R-12
LP-CC-30
(3) FNQ-R-3
KTK-R-5
(3) FNQ-R-5
KTK-R-10
(3) FNQ-R-10
FT-3 Fuse tester/puller
6-inch Crescent wire stripper
Kit contents
LPN-RK-10SP
(3) LPS-RK-10SP
LPN-RK-15SP
(3) LPS-RK-15SP
LPN-RK-20SP
(3) LPS-RK-20SP
LPN-RK-25SP
(3) LPS-RK-30SP
LPN-RK-30SP
(3) LPS-RK-60SP
LPN-RK-60SP
(3) LPS-RK-100SP
LPN-RK-100SP
NO.263-R (60 to 30A fuse reducer)
NO.663-R (60 to 30A fuse reducer)
FP-2 Fuse puller
858-inch Crescent linemans pliers
Kit contents
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(1)
FNM-1
(3) KTK-20
FNM-2
(3) KTK-30
FNM-5
(3) FNQ-5
FNM-10
(3) FNQ-10
FNM-15
(3) FNQ-15
KTK-5
(3) FNQ-20
KTK-10
(3) FNQ-30
KTK-15
(1) FT-3 Fuse tester/puller
15-2
(3) FRN-R-10
(3) FRS-R-10
(3) FRN-R-15
(3) FRS-R-15
(3) FRN-R-20
(3) FRS-R-20
(3) FRN-R-25
(3) FRS-R-30
(3) FRN-R-30
(3) FRS-R-60
(3) FRN-R-60
(3) FRS-R-100
(3) FRN-R-100
(1) FP-2 Fuse puller
(1) NO.263-R (60 to 30A fuse reducer)
(1) NO.663-R (60 to 30A fuse reducer)
(1) 6-inch Crescent wire stripper
Kit contents
1007July 2015
LPJ-3SP
(3) LPJ-25SP
LPJ-5SP
(3) LPJ-30SP
LPJ-6SP
(3) LPJ-40SP
LPJ-10SP
(3) LPJ-50SP
LPJ-15SP
(3) LPJ-60SP
LPJ-20SP
(3) LPJ-100SP
FP-2 Fuse puller
858-inch Crescent linemans pliers
Kit contents
Eaton.com/bussmannseries
15
Supplemental/branch
circuit
Branch circuit
Class CC / midget
fuse kit
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(1)
FNQ-R-12
FNQ-R-1
FNQ-R-2
FNQ-R-3
FNQ-R-4
FNQ-R-5
FNQ-10
FNQ-15
FNQ-20
FP-2 fuse puller
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
KTK-R-1
KTK-R-2
KTK-R-3
KTK-R-5
KTK-R-6
KTK-R-10
KTK-R-15
KTK-R-20
KTK-R-30
(2)
(2)
(2)
(2)
(3)
(2)
(4)
(2)
FRN-R-3-210
FRN-R-6-14
FRN-R-10
FRN-R-15
FRN-R-20
FRN-R-25
FRN-R-30
FRN-R-35
(2)
(2)
(3)
(2)
(2)
(2)
(2)
FRN-R-40
FRN-R-50
FRN-R-60
FRN-R-100
NO.263-R reducers
NO.1 clip clamps
NO.2 clip clamps
(2)
(2)
(2)
(2)
(3)
(2)
(4)
(2)
LPN-RK-3-210SP
LPN-RK-6-14SP
LPN-RK-10SP
LPN-RK-15SP
LPN-RK-20SP
LPN-RK-25SP
LPN-RK-30SP
LPN-RK-35SP
(2)
(2)
(3)
(2)
(2)
(2)
(2)
(1)
LPN-RK-40SP
LPN-RK-50SP
LPN-RK-60SP
LPN-RK-100SP
NO.263-R reducers
NO.1 clip clamps
NO.2 clip clamps
FP-2 fuse puller
Accessories
1007July 2015
Eaton.com/bussmannseries
15-3
15
Assortment contents
Assortment contents
(5) MDL-18
(5) AGC-12
(5) MDL-14
(5) AGC-34
(5) MDL-12
(5) AGC-1
(5) MDL-34
(5) AGC-1-12
(5) MDL-1
(5) AGC-2
(5) AGC-2-12
(5) MDL-1-12
(5) MDL-2
(5) AGC-3
(5) MDL-3
(5) AGC-4
(5) MDL-4
(5) AGC-5
(5) MDL-5
(5) AGC-6
(5) MDL-6
(5) AGC-7
(5) MDA-8
(5) AGC-8
(5) MDA-10
(5) ABC-10
(5) MDA-15
(5) ABC-15
(5) MDA-20
(5) ABC-20
(5) MDA-30
(5) ABC-30
(5) AGC-18
(5) GMA-250mA
(5) AGC-14
(5) GMA-500mA
(2) Pr. 4121 fuse clips
(2) HHB inline fuse holder
(1) HTB-26I panel mount fuse holder
(1) HTB-28M panel mount fuse holder
(1) S-8202-2 two-pole fuse block
15-4
(5) GMA-1A
(5) GMA-2A
(5) GMA-3A
(5) GMA-4A
(5) GMA-6A
(5) GMC-1A
(5) GMC-2A
(5) GMC-3A
(5) GMC-4A
(5) GMC-6A
(4) AGC-V-12
(4) AGC-V-1
(4) AGC-V-2
(4) AGC-V-3
(4) MDL-V-12
(4) MDL-V-1
(4) MDL-V-2
(4) MDL-V-3
(5) MDL-12
(5) MDL-1
(5) MDL-1-12
(5) MDQ-2
(5) MDQ-3
(5) MDQ-4
(5) MDQ-5
(5) MDQ-6
(5) MDA-8
(5) MDA-10
(5) MDA-15
(5) MDA-20
(5) MDA-30
(5) AGC-14
(5) AGC-12
(5) AGC-1
(5) AGC-1-12
(5) AGC-2
(5) AGC-3
(5) AGC-4
(5) AGC-5
(5) AGC-6
(5) AGC-7
(5) AGC-8
(5) ABC-10
(5) ABC-15
(5) ABC-20
(5) ABC-30
(2) Pr. #4121 fuse clips
(2) HHB Inline fuse holder
(1) FP-A3 fuse puller
1007July 2015
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(1)
(1)
Eaton.com/bussmannseries
GMD-200mA
GMD-500mA
GMD-1
GMD-1.6
GMD-2
GMD-3
GDC-250mA
GDC-500mA
GDC-1
GDC-1.6
GDC-2
GDC-3.15
GDC-4
GDC-5
TRON clip-clamps
Specifications:
Description: Clamps
for ferrule and bladetype cartridge fuse
clips. Provide tight
contacts between fuse
holder clips and fuse
ferrules/blades.
Construction:
Phenolic knob and
plated-steel jaws.
Catalog
numbers
NO.1
NO.2
NO.2
NO.4
NO.5
NO.6
NO.7
NO.8
Clamp size
volts
250
250
600
600
250/600
250/600
250/600
250/600
Catalog numbers
Amps
0-30
35-60
0-30
35-60
70-100
110-200
225-400
450-600
15
Fuse block
class
CC*
G
H (250V)*
J (30A, 60A*
R (250)*
M Type*
DRA-2
Rail type
DIN
American
Size
15mm (Sym.)
32mm (Asym.)
35mm (Sym.)
64 (Sym.)
(also 35mm DIN)
17
Adapter
color
Black
Gray
Accessories
1007July 2015
Eaton.com/bussmannseries
15-5
15
Fuse pullers
FP-6
FP-2
Specifications:
Description: Spare fuse holders
durably constructed using black
thermoplastic with common mounting
using #6 screws or bolts on 5-inch
centers. Dovetailed interlocking between
fuse holders simplifies installation and
reduces needed hardware. Common
footprint allows for any combination of
fuse holders to be mounted together.
Built-in retaining clips secure fuses.
Flammability rating: UL 94V0.
Catalog
numbers
TPSFH-CW
TPSFH-M
TPSFH-LC
TPSFH-LB
TPSFH-N60
TPSFH-N30
TPSFH-AS
TPSFH-T
Catalog numbers
Capacity
4-position
4-position
1-position
1-position
1-position
4-position
6-position
10-position
FP-3
CFP-(Amp)
FP-4
FP-A3
Specifications:
Description: Fuse pullers in various
sizes to safely and easily extract fuses
from blocks and holders.
Catalog numbers
Catalog numbers
Application
13
FP-2
32 to 1316 dia. fuses
FP-3
1 to 1 34 dia. fuses
FP-4
1 34 to 2 12 dia. fuses
FP-6
0-60A T-Tron fuses
FP-A3
Glass tube and ATC fuses
CFP-30
CUBEFuse 1-30A
CFP-60
CUBEFuse 35-60A
CFP-100
CUBEFuse 70-100A
Fuse pullers are only to be used when the associated circuit
has been de-energized.
Specifications:
Description: Spare fuse cabinet with
five cubic feet of storage space.
Constructed of heavy gauge steel with
durable baked ASA 61 grey enamel
finish. Cabinet door is equipped with
locking handle for security. Mounting
holes are 16 inches on center with key
slots.
Size: 24 W x 30 H x 12 D
Material: 0.062 sheet steel
Catalog numbers:
SFC-FUSE-CAB
SFC-SHELF*
5TPH
Specifications:
Description: 5-position spare fuse
holder for midget size and Class CC
fuses (1332 diameter) fuses. Constructed
of thermoplastic with adhesive tape on
back for easy mounting on cabinet doors.
Size: 2.98 W x 1.03 H x 0.63 D
Catalog number: 5TPH
Data Sheet: 5014
15-6
Specifications:
Description: Fuse tester for automotive,
glass tube and ferrule fuses up to 178
length. Probe slides to appropriate fuse
length. Batteries are included and
replaceable.
WARNING: DO NOT test electrical
fuses in the fuse panel.
Catalog number: FT-2
Replacement battery:
Rayovac 364
1007July 2015
Eaton.com/bussmannseries
Specifications:
Description: Fuse tester for
automotive, glass tube and ferrule
fuses up to 114 length. Probe slides
to appropriate fuse length. Batteries
are included and replaceable.
WARNING: DO NOT test electrical
fuses in the fuse panel.
Catalog number: FT-3
15
Catalog numbers
Fuse
amp size range
1-30
1-30
35-60
35-60
70-100
70-100
110-200
110-200
225-400
Equipment/fuse block
amp size
60
100
100
200
200
400
400
600
600
Catalog numbers
Catalog
numbers
NNB
NNB-R
NNC
NTN-R-30
NTN-R-60
NTN-R-100
NTN-R-200
NTN-R-400
NTN-R-600
NTS-R-30
NTS-R-60
NTS-R-100
NTS-R-200
NTS-R-400
NTS-R-600
Voltage
250
250
250
250
250
250
600
600
600
600
600
600
Fuse equivalent
Dimension
13
32 x 112
Class CC
1
4 x 114
Class R/H
Class R/H
Class R/H
Class R/H
Class R/H
Class R/H
Class R/H
Class R/H
Class R/H
Class R/H
Class R/H
Class R/H
Fuse
amp size range
1-30
35-60
70-100
110-200
225-400
450-600
1-30
35-60
70-100
110-200
225-400
450-600
(pairs)
Catalog numbers
Fuse
Equipment/fuse block
600V
amp size range
amp size
NO.663-R
1-30
60
NO.216-R
1-30
100
NO.616-R
35-60
100
NO.626-R
35-60
200
NO.2621-R
70-100
200
NO.2641-R
70-100
400
NO.642-R
110-200
400
NO.2661-R
70-100
600
NO.2662-R
110-200
600
NO.2664-R**
225-400
600
Accessories
250V
reducer
NO.263
NO.213
NO.216
NO.226
NO.2621
NO.2641
NO.2642
No. 2661
No. 2662
No. 2664
600V
reducer
NO.663
NO.216
NO.616
NO.626
NO.2621
NO.2641
NO.2642
NO. 2661
NO. 2662
NO. 2664
Fuse
amp size range
1-30
1-30
35-60
35-60
70-100
70-100
110-200
70-100
110-200
225-400
Equipment/
fuse block
amp size
60
100
100
200
200
400
400
600
600
600
1007July 2015
Eaton.com/bussmannseries
15-7
Compact modular
fuse holders
15-8
1007July 2015
Eaton.com/bussmannseries
Services
Eaton services and application guide
16
Contents
Description
Page
Eaton services
Testing................................................................................16-2
Custom products.................................................................16-3
Application guide
Fuse technology .................................................................16-4
Motor circuit branch circuit protection ..............................16-11
Glossary ...........................................................................16-12
Out-of-stock substitution/upgrades ..................................16-14
Industrial and commercial fuse applications......................16-15
Mobile apps........................................................................16-16
FuseFinder cross reference guide...................................16-18
Catalog number index.......................................................16-20
Services and
application guide
1007July 2015
Eaton.com/bussmannseries
16-1
16
Services
Testing
Circuit breakers
Fuses
ETL
CE
Underwriters
Laboratories
ANSI
CSA
IEC, and
To Order:
To find out more contact your local
Eaton representative, or visit us
online at:
www.cooperbussmann.com/services.
16-2
1007July 2015
Eaton.com/bussmannseries
Hourly rate
Hourly rate
Hourly Rate
Catalog number
CBSV-ES-TEHP
CBSV-ES-TEMP
CBSV-ES-TELP
Services
Custom products
16
In-house testing
Services and
application guide
CSA
ETL
IEC, and
Underwriters Laboratories
1007July 2015
Eaton.com/bussmannseries
16-3
Application guide
16
Fuse technology
Circuit protection
Overloads are most often between one and six times the
normal current level. Usually, they are caused by harmless
temporary surge currents that occur when motors are
started-up or transformers are energized. Such overload
currents, or transients, are normal occurrences. Since they are
of brief duration, any temperature rise is trivial and has no
harmful effect on the circuit components. (It is important that
protective devices do not react to them.)
16-4
1007July 2015
2. Properly applied, fuses prevent blackouts. Only the fuse nearest a fault
opens without upstream fuses (feeders or mains) being affectedfuses
thus provide selective coordination. (These terms are precisely defined
in subsequent pages.)
3. Fuses provide optimum component protection by keeping fault currents
to a low valueThey are said to be current limiting.
Voltage rating
Eaton.com/bussmannseries
Application guide
Fuse technology
A typical example is the motor circuit; dual-element fuses
generally are permitted to be sized up to 175% and non-timedelay fuses up to 300% of the motor full-load amps. As a rule,
the amp rating of a fuse and switch combination should be
selected at 125% of the continuous load current (this usually
corresponds to the circuit capacity, which is also selected at
125% of the load current). There are exceptions, such as when
the fuse-switch combination is approved for continuous
operation in an assembly at 100% of its rating.
LPS-RK
200SP
It is a simple matter to selectively coordinate modern currentlimiting fuses. By maintaining a minimum ratio of fuse-amp
ratings between an upstream and downstream fuse, selective
coordination is assured.
Initiation of
short-circuit
current
A non-current-limiting protective device, by permitting a shortcircuit current to build up to its full value, can let an immense
amount of destructive short-circuit heat energy through before
opening the circuit.
Current-limiting
1007July 2015
Eaton.com/bussmannseries
16-5
Services and
application guide
KRP-C
1200SP
Normal
load current
Interrupting rating
16
16
Application guide
Fuse technology
The high total resistance of the multiple arcs, together with the
quenching effects of the filler particles, results in rapid arc
suppression and clearing of the circuit. (Refer to Figures 4 & 5)
Short-circuit current is cut off in less than a half-cycle, long
before the short-circuit current can reach its full value (fuse
operating in its current limiting range).
16-6
1007July 2015
Eaton.com/bussmannseries
Application guide
Fuse technology
16
Filler material
Figure 6. This is the LPS-RK100SP, a 100A, 600V Low-Peak, Class RK1, dual-element fuse that has excellent time-delay, excellent current-limitation and a 300kA interrupting rating. Artistic
liberty is taken to illustrate the internal portion of this fuse. The real fuse has a non-transparent tube and special small granular, arc-quenching material completely filling the internal space.
Short-circuit element
Overload element
Figure 7. The true dual-element fuse has distinct and separate
p
overload element and
short-circuit element.
Figure 9. Short-circuit operation: Modern fuses are designed with minimum metal in the
restricted portions which greatly enhance their ability to have excellent current-limiting
characteristics minimizing the short circuit let-through current. A short-circuit current causes
the restricted portions of the short-circuit element to vaporize and arcing commences. The arcs
burn back the element at the points of the arcing. Longer arcs result, which assist in reducing the
current. Also, the special arc quenching filler material contributes to extinguishing the arcing
current. Modern fuses have many restricted portions, which results in many small arclets all
working together to force the current to zero.
Before
Figure 8. Overload operation: Under sustained overload conditions, the trigger spring
fractures the calibrated fusing alloy and releases the connector. The insets represent a model
of the overload element before and after. The calibrated fusing alloy connecting the short-circuit
element to the overload element fractures at a specific temperature due to a persistent overload
current. The coiled spring pushes the connector from the short-circuit element and the circuit is
interrupted.
Figure 10. Short-circuit operation: The special small granular, arc-quenching material plays
an important part in the interruption process. The filler assists in quenching the arcs; the filler
material absorbs the thermal energy of the arcs, fuses together and creates an insulating barrier.
This process helps in forcing the current to zero. Modern current-limiting fuses, under shortcircuit conditions, can force the current to zero and complete the interruption within a few
thousandths of a second.
When the short-circuit current is in the current-limiting range of a fuse, it is not possible for the full available short-circuit current to flow through the fuse its a matter of
physics. The small restricted portions of the short-circuit element quickly vaporize and the filler material assists in forcing the current to zero. The fuse is able to limit the
short-circuit current.
Overcurrent protection must be reliable and sure. Whether it is the first day of the electrical system or thirty or more years later, it is important that overcurrent protective
devices perform under overload or short-circuit conditions as intended. Modern current-limiting fuses operate by very simple, reliable principles.
1007July 2015
Eaton.com/bussmannseries
16-7
Services and
application guide
After
16
Application guide
Fuse technology
Below is a rerating chart for single element fuses or non dual element fuses.
400
300
200
100
80
60
40
30
20
130
Affect on Carrying
Capacity Rating
120
110
100
70
4
3
2
1
.8
.6
90
80
10
8
6
TIME IN SECONDS
150
LOW-PEAK
LPN-RK200 SP (RK1)
.4
.3
Affect on
Opening Time
.2
60
50
40
30
76F
40F
4F
(60C) (40C) (20C)
32F
(0C)
68F
(20C)
104F
(40C)
140F
(60C)
176F
(80C)
212F
(100C)
AMBIENT
.1
.08
.06
.04
.03
.02
CURRENT IN AMPS
16-8
1007July 2015
Eaton.com/bussmannseries
6,000
8,000
10,000
3,000
4,000
2,000
600
800
1,000
300
400
200
100
.01
Application guide
Fuse technology
16
Classes of fuses
Services and
application guide
Class R fuses
1007July 2015
Eaton.com/bussmannseries
16-9
16
Application guide
Fuse technology
These are fuses that can have many voltages and interrupting
ratings within the same case size. Examples of supplemental
fuses are 13/32'' X 1 1/2'', 5 x 20mm, and 1/4'' x 1 1/4'' fuses.
Interrupting ratings range from 35 to 100kA.
16-10
1007July 2015
Eaton.com/bussmannseries
Application guide
Motor circuit branch circuit protection
2. The typical level of short-circuit protection for the motor starter provided
by circuit breakers and MCPs is referred to as Type 1. This is because
most circuit breakers are not current-limiting. So, for a loadside fault,
the starter may sustain significant damage such as severe welding of
contacts and rupturing of the heater elements. Or the heater/overload
relay system may lose calibration. This is an acceptable level of
performance per UL 508, which is the product standard for motor
starters. Current-limiting fuses can be selected that can provide Type 2
No Damage short-circuit protection for motor starters.
Consequently, with circuit breaker protection, after a fault condition,
1007July 2015
Eaton.com/bussmannseries
16-11
Services and
application guide
16
Application guide
16
Glossary
Ampere (Amp)
Class G fuses
Amp rating
Class H fuses
Class J fuses
Class R fuses
Breaking capacity
Class L fuses
Clearing time
Arcing I2t
16-12
1007July 2015
Eaton.com/bussmannseries
Classes of fuses
Application guide
Glossary
Dual-element fuse
Melting I2t
Electrical load
NEC dimensions
Fast-acting fuse
Ohm
Fuse
Ohms law
Interrupting Rating IR
Overload
Interrupting capacity
(Breaking capacity)
1007July 2015
Eaton.com/bussmannseries
16-13
Services and
application guide
16
Application guide
16
Glossary
Out-of-stock
substitution/upgrades
Single-phasing
Bussmann series #
AGC-(AMP)
Upgrade #
ABC-(AMP)
Description
Fast-acting, 1/4 x 1 1/4 fuse
AGC-V-(AMP)
ABC-V-(AMP)
AGU-(AMP)
LP-CC-(AMP)
2008
BAF-(AMP)
LP-CC-(AMP)
2011
BAN-(AMP)
LP-CC-(AMP)
2046
DCM-(AMP)
PVM-(AMP)
2153
DCM-(AMP)
KLM-(AMP)
2020
1315
DLN-(AMP)
ECNR-(AMP)
ECSR-(AMP)
1318
FNM-(AMP)
LP-CC-(AMP)
2028
FNQ-R-(AMP)
LP-CC-(AMP)*
1012
FNR-R-(AMP)
LPN-RK-(AMP)SP
1019/1020
FRS-R-(AMP)
LPS-RK-(AMP)SP
1017/1018
JKS-(AMP)
LPJ-(AMP)SP
1026/1027
KLU-(AMP)
KRP-C-(AMP)SP
1013
KTK-(AMP)
KTK-R-(AMP)
1011
KTK-R-(AMP)
LP-CC-(AMP)
1015
KTN-R-(AMP)
LPN-RK-(AMP)SP
1043
KTS-R-(AMP)
LPS-RK-(AMP)SP
1044
KTU-(AMP)
KPR-C-(AMP)SP
1010
KWS-R-(AMP)
LPS-RK-(AMP)SP
1044
MDL-(AMP)
MDA-(AMP)
2004
2004
MDL-V-(AMP)
MDA-V-(AMP)
MTH-(AMP)
AGC-(AMP)
NON-(AMP)
LPN-RK-(AMP)SP
NOS-(AMP)
LPS-RK-(AMP)SP
1030
REN-(AMP)
LPN-RK-(AMP)SP
1028
RES-(AMP)
LPS-RK-(AMP)SP
1028
SL-(AMP)
S-(AMP)
1033
TL-(AMP)
T-(AMP)
1035
W-(AMP)
TL-(AMP)
1035
2001
DLS-(AMP)
16-14
Data Sheet #
2001
1007July 2015
Eaton.com/bussmannseries
1030
Application guide
Industrial and commercial fuse applications
16
Industrial applications
1. Interior lighting
2. Computer power
3. Switchboards
4. Motor control center
5. Emergency lighting
6. UPS backup power supplies
7. Transformer/emergency generator
8. Forklift battery charging station
9. HVAC chillers/blowers
10. Welding circuits
11. Plant lighting
12. Distribution panels
13. Disconnect switches
14. Programmable logic circuits
15. Conveyor system
Commercial applications
1. Interior lighting
2. HVAC blowers
3. Computer power
4. Branch circuits
5. Emergency lighting
6. Load centers
7. Disconnect/distribution panels
8. HVAC chillers
9. Switchboards/motor control centers
10. UPS backup power supplies
11. Elevator control centers
12. Transformer/emergency generator
Services and
application guide
1007July 2015
Eaton.com/bussmannseries
16-15
FREE APPS
Bussmann series FuseFinder
Search comprehensive competitor cross references at
your fingertips.
16-16
1007July 2015
Eaton.com/bussmannseries
SERIES
Eaton offers more possibilities
Expanding our products.
Expanding our thinking.
Energizing your business.
Eaton.com/bussmannseries
Follow us on social media to get the
latest product and support information.
1007July 2015
Eaton.com/bussmannseries
16-17
16
Eaton, the industry leader in critical circuit protection, power management and electrical safety offers an extensive
selection of Bussmann series fuses and fuse blocks to meet precise overcurrent protection needs.
Whether its glass tube, low voltage or high speed fuses or fuse blocks needed for an application, you can use
this FuseFinder quick cross reference guide to find the Bussmann series replacement. If you cannot find a cross,
more extensive listings are available online at www.cooperbussmann.com/FuseFinder. Or contact our Application
Engineers at FuseTech@eaton.com.
Competitor
fuse family
Bussmann
series
Competitor
fuse family
Bussmann
series
Competitor
fuse family
Bussmann
series
0481(AMP)
211(AMP)
212(AMP)
213(AMP)
215(AMP)
216(AMP)
217(AMP)
218(AMP)
221(AMP)
226(AMP)
227(AMP)
228(AMP)
230(AMP)
235(AMP)
236(AMP)
238(AMP)
239(AMP)
257(AMP)
297(AMP)[AUTOMOTIVEFUSE]
299(AMP)
2AG220
2AG230
301(AMP)
303(AMP)
307(AMP)
311(AMP)
312(AMP)
313(AMP)
314(AMP)
315(AMP)
318(AMP)
322(AMP)
323(AMP)
324(AMP)
325(AMP)
326(AMP)
334(AMP)
336(AMP)
361(AMP)
362(AMP)
3770(AMP)
3780(AMP)
3785(AMP)
3AB(AMP)
3ABP(AMP)
3AG(AMP)
3AG311(AMP)
3AG312(AMP)
3AG313(AMP)
3AG315(AMP)
3AG318(AMP)
3SB(AMP)
3SBP(AMP)
401(AMP)
411(AMP)
412(AMP)
GMT-(AMP)A
GDC-(AMP)
GDB-(AMP)
GDC-(AMP)
S505-(AMP)
GDA-(AMP)
GDB-(AMP)
GDC-(AMP)
S505-V-(AMP)
GDA-V-(AMP)
GDB-V-(AMP)
GDC-V-(AMP)
C515-(AMP)
GMA-(AMP)
GMA-V-(AMP)
GMD-V-(AMP)
GMD-(AMP)
ATC-(AMP)
ATM-(AMP)
MAX-(AMP)
C517-(AMP)
C515-(AMP)
AGA-(AMP)
AGW-(AMP)
SFE-(AMP)
AGC-(AMP)
AGC-(AMP)
MDL-(AMP)
ABC-(AMP)
MDL-V-(AMP)
AGC-V-(AMP)
GBB-(AMP)
MDA-(AMP)
ABC-V-(AMP)
MDA-V-(AMP)
MDA-(AMP)
GLD-(AMP)
GBA-(AMP)
AGX-(AMP)
AGX-(AMP)
SL-(AMP)
S-(AMP)
T-(AMP)
ABC-(AMP)
AGC-V-(AMP)
AGC-(AMP)
AGC-(AMP)
AGC-(AMP)
MDL-(AMP)
MDL-V-(AMP)
AGC-V-(AMP)
MDL-(AMP)
MDL-V-(AMP)
GMT-(AMP)A
ABS-(AMP)
ABS-(AMP)
413(AMP)
414(AMP)
417(AMP)
418(AMP)
429(AMP)
431(AMP)
5140(AMP)
5170(AMP)
523(AMP)
5HF(AMP)
5HFP(AMP)
5HT(AMP)
5MF(AMP)
5MFP(AMP)
5SF(AMP)
5ST(AMP)
6J(AMP)X
6R(AMP)D
702(AMP)
703(AMP)
81200(AMP)ST
A70P(AMP)-1 or Type 1
A70P(AMP)-4 or Type 4
A70Q(AMP)-4 or Type 4
A70QS(AMP)-14F
A70QS(AMP)-22F
A70QS[35-200]-4
A70QS[225-400]-4 or 4K
A70QS[450-600]-4K
A70QS[700-800]-4
A50P(AMP)-1
A50P(AMP)-4
A50QS(AMP)-4 or Type 4
A30QS(AMP)-1 or Type 1
A30QS[35-700]-4 or Type 4
A30QS[1000-1200]-128
A15QS[1-30]-2
A15QS[35-60]-1
A15QS[70-400]-4
A2D(AMP)R
A2K(AMP)
A3T(AMP)
A4BQ[225-600]
A4BQ[601-6000]
A4BT[601-4000]
A4BY(AMP)
A4J(AMP)
A6D(AMP)R
A6K(AMP)
A6T(AMP)
AG(AMP)
AJT(AMP)
AM10/(AMP)
AOK(AMP)
ATDR(AMP)
ATM(AMP)
MDM-(AMP)
ABS-(AMP)
ABS-(AMP)
TR/3216FF-(AMP)
3216FF(AMP)
0603FA(AMP)
BAF-(AMP)
AGU-(AMP)
FNM-(AMP)
GDA-(AMP)
GDA-V-(AMP)
S505-(AMP)A
GMA-(AMP)
GMA-V-(AMP)
GDB-(AMP)
GDC-(AMP)
KTK-(AMP)
LPS-RK-(AMP)SP
HVJ-(AMP)
HVL-(AMP)
CBS-(AMP)
FWP-(AMP)A14F
FWP-(AMP)A orB
FWP-(AMP)A or B
FWP-(AMP)A14F
FWP-(AMP)A22F
FWP-(AMP)A or B
FWP-(AMP)A or B
FWP-(AMP)A or B
FWP-(AMP)A or B
FWH-(AMP)A14F
FWH-(AMP)A or B
FWH-(AMP)A or B
FWX-(AMP)A14F
FWX-(AMP)A
FWX-(AMP)AH
FWA-(AMP)A10F
FWA-(AMP)A21F
FWA-(AMP)B
LPN-RK(AMP)SP
KTN-R(AMP)
JJN(AMP)
KRP-CL-(AMP)
KRP-C-(AMP)SP
KLU[601-4000]
KLU(AMP)
JKS(AMP)
LPS-RK(AMP)SP
KTS-R(AMP)
JJS(AMP)
SC(AMP)
LPJ(AMP)SP
LP-CC-(AMP)
ALS-(AMP)
LP-CC-(AMP)
KLM(AMP)
ATMR(AMP)
ATQ(AMP)
ATQR(AMP)
BBC(AMP)
BDB(AMP)
BDC(AMP)
BDL(AMP)
BGC(AMP)
BGX(AMP)
BLF(AMP)
BLN(AMP)
BLS(AMP)
BMA(AMP)
CBO(AMP) [4-160A]
CCK(AMP) [1-300A]
CCL(AMP) [30-100A]
CCLB(AMP) [20-250A]
CCLW(AMP) [1-300A]
CCMR[1-30A Only]
CDNC(AMP)
CDSC(AMP)
CNL(AMP)
CNN(AMP)
DCT[1-15A]
E(AMP)FC
E(AMP)FE
E(AMP)FET
E(AMP)FM
E(AMP)FMM
E(AMP)LCT [6-20A]
E(AMP)LET [25-180A]
E(AMP)LMMT [315-900A]
E(AMP)LMT [160-450A]
E100SF(AMP) [20-30A]
E100S(AMP) [40-2000A]
E15S(AMP) [35-3000A]
E15SF(AMP) [5, 10, 15, 20, 25, 30A]
E25S(AMP) [1000-2500A]
E25S(AMP) [35-800A]
E25SFX(AMP) [5-30A]
E50S(AMP)
E50SF(AMP) [5-30A]
E70S(AMP)
ECK(AMP) [1-300A]
ECL(AMP) [30-100A]
ECN(AMP)
ECNR(AMP)
ECS(AMP)
ECSR(AMP)
ELR(AMP)
ENLE(AMP)
ENNE(AMP)
ERN(AMP)
ERS(AMP)
ESA(AMP)
FA(AMP)
KTK-R(AMP)
FNQ-(AMP)
FNQ-R-(AMP)
ABC-(AMP)
GDB-(AMP)
GDC-(AMP)
MDL-(AMP)
AGC-(AMP)
AGX-(AMP)
BAF-(AMP)
BAN-(AMP)
BBS-(AMP)
GDA-(AMP)
HBO-(AMP)
ACK-(AMP)
ACL-(AMP)
KGJ-E-(AMP)
KGJ-(AMP)
LP-CC(AMP)
CDN(AMP)
CDS(AMP)
ANL-(AMP)
ANN-(AMP)
PV-(AMP)A10F
(AMP)FC
(AMP)FE
(AMP)FET
(AMP)FM
(AMP)FMM
(AMP)LCT
(AMP)LET
(AMP)LMMT
(AMP)LMT
FWJ-(AMP)A14F
FWJ-(AMP)
FWA-(AMP)A
FWA-(AMP)A10F
FWX-(AMP)AH
FWX-(AMP)A
FWX-(AMP)14F
FWH-(AMP)
FWH-(AMP)14F
FWP-(AMP)
ACK-(AMP)
ACL-(AMP)
FRN-R-(AMP)
FRN-R-(AMP)
FRS-R-(AMP)
FRS-R-(AMP)
GLR-(AMP)
ANL-(AMP)
ANN-(AMP)
REN-(AMP)*
RES-(AMP)**
S-(AMP)
SA(AMP)
16-18
1007July 2015
Eaton.com/bussmannseries
16
Bussmann
series
Competitor
fuse family
Bussmann
series
Competitor
fuse blocks 1, 2, 3
Bussmann
series
FII(AMP)
FIIC(AMP)
FIIM(AMP) [125-200A]
FIIM(AMP) [80-100A]
FLA(AMP)
FLM(AMP)
FLN(AMP)
FLNR(AMP)
FLQ(AMP)
FLS(AMP)
FLSR(AMP)
GFN(AMP)
GGU(AMP)
GL10/(AMP)
HCLR(AMP)
HCTR(AMP)
HSJ(AMP)
IDSR[6-60A Only]
J(AMP)
JDL(AMP)
JFL(AMP)
JLLN(AMP)
JLLS(AMP)
JLS(AMP)
JTD(AMP)
KLA(AMP) [5, 10, 15, 20, 25, 30A]
KLB(AMP) [1-30A]
KLC(AMP)
KLDR (AMP)
KLH(AMP) [1-30A]
KLH(AMP) [225-600A]
KLH(AMP) [35-200A]
KLK(AMP)
KLKR(AMP)
KLLU(AMP)
KLMR(AMP)
KLNR(AMP)
KLPC(AMP)
KLSR(AMP)
KLW(AMP)
KON(AMP)
KOS(AMP)
L(AMP)TD
L15S(AMP) [1-30A]
L15S(AMP) [35-60A]
L15S(AMP) [70-400A]
L25S(AMP) [1-30A]
L50S(AMP) [1-30A]
L70S(AMP) [1-30A]
LCU(AMP)
LEN(AMP)
LENRK(AMP)
LES(AMP)
LESR(AMP)
LESRK(AMP)
LGR(AMP)
LHR(AMP)
LKU(AMP)
LLNRK(AMP)
LLSRK(AMP)
MEN(AMP)
MEQ(AMP)
MJS(AMP)
MOL(AMP)
NCL(AMP)
NCLR(AMP)
CGL-(AMP)
CGL-(AMP)
(AMP)M14CB
(AMP)L09CB
FNA-(AMP)
FNM-(AMP)
FRN-R-(AMP)
FRN-R-(AMP)
FNQ-(AMP)
FRS-R-(AMP)
FRS-R-(AMP)
FNA-(AMP)
AGU(AMP)
KTK-(AMP)
KTK-R-(AMP)
FNQ-R-(AMP)
DFJ(AMP)
FRS-R-(AMP)ID
JKS-(AMP)
LPJ-(AMP)SP
JKS-(AMP)
JJN-(AMP)
JJS-(AMP)
JKS-(AMP)
LPJ-(AMP)SP
FWA-(AMP)A10F
FWX-(AMP)A14F
KAC-(AMP)
FNQ-R-(AMP)
FWH-(AMP)A14F
FWH-(AMP)A
FWH-(AMP)B
KTK-(AMP)
KTK-R-(AMP)
KLU-(AMP)
LP-CC-(AMP)
KTN-R-(AMP)
KRP-C-(AMP)SP
KTS-R-(AMP)
FWA-(AMP)10F
NON-(AMP)
NOS-(AMP)
KRP-C-(AMP)SP
FWA-(AMP)A10F
FWA-(AMP)A21F
FWA-(AMP)A
FWX-(AMP)A14F
FWH-(AMP)A14F
FWP-(AMP)A14F
KTU-(AMP)
FRN-R-(AMP)
LPN-RK-(AMP)SP
FRS-R-(AMP)
FRS-R-(AMP)
LPS-RK-(AMP)SP
GLR-(AMP)
HLR(AMP)
KLU-(AMP)
LPN-RK-(AMP)SP
LPS-RK-(AMP)SP
FNM-(AMP)
FNQ-(AMP)
C515-(AMP)
BAF-(AMP)
KTN-R-(AMP)
KTN-R-(AMP)
NLN(AMP)
NLS(AMP)
OT(AMP)
OTM(AMP)
OTS(AMP)
RF(AMP)
RFS(AMP)
RLN(AMP)
RLS(AMP)
SAO(AMP)
SBS(AMP)
SCL(AMP)
SCLR(AMP)
SEC(AMP)
SLC(AMP)
SLO(AMP)
SOO(AMP)
TLO(AMP)
TOO(AMP)
TR(AMP)
TRM(AMP)
TRS(AMP)
WOO(AMP)
NON-(AMP)
NOS-(AMP)
NON(AMP)
BAF-(AMP)
NOS(AMP)
REN(AMP)*
RES(AMP)**
REN-(AMP)*
RES(AMP)**
SA-(AMP)
BBS-(AMP)
KTS-R-(AMP)
KTS-R-(AMP)
SC-(AMP)
SC-(AMP)
SL-(AMP)
S-(AMP)
TL-(AMP)
T-(AMP)
FRN-R-(AMP)
FNM-(AMP)
FRS-R(AMP)
W-(AMP)
Competitor
fuse blocks 1, 2, 3
Bussmann
series
LFJ60030(X) / (X)ID
LFJ60060(X) / (X)ID
LFJ60100(X) / (X)ID
LFJ60200(X) / (X)ID
LFJ60400(X) / (X)ID
LFJ60600(X) / (X)ID
LFR25030(X) / (X)ID
LFR25060(X) / (X)ID
LFR25100(X) / (X)ID
LFR25200(X) / (X)ID
LFR25400(X) / (X)ID
LFR25600(X) / (X)ID
LFR60030(X) / (X)ID
LFR60060(X) / (X)ID
LFR60100(X) / (X)ID
LFR60200(X) / (X)ID
LFR60400(X) / (X)ID
LFR60600(X) / (X)ID
LFH25030(X) / (X)ID
LFH25060(X) / (X)ID
LFH25100(X) / (X)ID
LFH25200(X) / (X)ID
LFH25400(X) / (X)ID
LFH25600(X) / (X)ID
LFH60030(X) / (X)ID
LFH60060(X) / (X)ID
LFH60100(X) / (X)ID
LFH60200(X) / (X)ID
LFH60400(X) / (X)ID
LFH60600(X) / (X)ID
LFPSJ30(X) / (X)ID
LFPSJ60(X) / (X)ID
LPHV
LPSC00(X) / (X)ID
LPSM00(X) / (X)ID
6030(X)J
6060(X)J
610(XX)J
JM60030-(X)CR
JM60060-(X)CR
JM60100-(X)CR***
JM60200-(X)CR***
JM60400-(X)CR***
JM60600-(X)CR***
RM25030-(X)CR
RM25060-(X)CR
RM25100-(X)CR***
RM25200-(X)CR***
RM25400-(X)CR***
RM25600-(X)CR***
RM60030-(X)CR
RM60060-(X)CR
RM60100-(X)CR***
RM60200-(X)CR***
RM60400-(X)CR***
RM60600-(X)CR***
HM25030-(X)CR
HM25060-(X)CR
HM25100-(X)CR***
HM25200-(X)CR***
HM25400-(X)CR***
HM25600-(X)CR***
HM60030-(X)CR
HM60060-(X)CR
HM60100-(X)CR***
HM60200-(X)CR***
HM60400-(X)CR***
HM60600-(X)CR***
CH30J(X) / (X)I
CH60J(X) / (X)I
CHPV
CHCC(X)DU / (X)DIU
CHM(X)DU / CHM(X)DIU
JM60030-(X)CR
JM60060-(X)CR
JM60100-(X)CR***
620(XX)J
640(XX)J
66(XX)J
203(XX)
206(XX)
210(XX)
220(XX)
240(XX)
26(XX)
603(XX)
606(XX)
610(XX)
620(XX)
640(XX)
66(XX)
203(XX)R
206(XX)R
210(XX)R
220(XX)R
240(XX)R
26(XX)R
603(XX)R
606(XX)R
610(XX)R
620(XX)R
640(XX)R
66(XX)R
US3J(X) / (X)I
US6J(X) / (X)I
USPV
USCC(X) / (X)I
USM(X) / (X)I
(R)6J30A(X)S
(R)6J60A(X)B
R6J100A(X)B
6J200A(X)BFBD
6J400A(X)BFBD
6J600A(X)BFBD
R30A(X)(XX)
R60A(X)(XX)
R100A(X)B
R200A(X)BE
R400A(X)B
R600A(X)B
6R30A(X)(XX)
6R60A(X)(XX)
6R100A(X)B
6R200A(X)BE
6R400A(X)B
6R600A(X)B
(R)F30A(X)(XX)
(R)F60A(X)(XX)
RF100A(X)B
F200A(X)BE
RF400A(X)B
F600A(X)B
(R)6F30A(X)(XX)
(R)6F60A(X)(XX)
R6F100A(X)B
6F200A(X)BE
R6F400A(X)B
6F600A(X)B
6SJ30A(X) / (X)I
6SJ60A(X) / (X)I
6SC30A(X)-C / (X)I-C
6SM30A(X)-C / (X)I-C
JM60200-(X)CR***
JM60400-(X)CR***
JM60600-(X)CR***
HM25030-(X)CR
HM25060-(X)CR
HM25100-(X)CR***
HM25200-(X)CR***
HM25400-(X)CR***
HM25600-(X)CR***
HM60030-(X)CR
HM60060-(X)CR
HM60100-(X)CR***
HM60200-(X)CR***
HM60400-(X)CR***
HM60600-(X)CR***
RM25030-(X)CR
RM25060-(X)CR
RM25100-(X)CR***
RM25200-(X)CR***
RM25400-(X)CR***
RM25600-(X)CR***
RM60030-(X)CR
RM60060-(X)CR
RM60100-(X)CR***
RM60200-(X)CR***
RM60400-(X)CR***
RM60600-(X)CR***
CH30J(X) / (X)I
CH60J(X) / (X)I
CHPV
CHCC(X)DU / (X)DIU
CHM(X)DU / CHM(X)DIU
JM60030-(X)CR
JM60060-(X)CR
JM60100-(X)CR***
JM60200-(X)CR***
JM60400-(X)CR***
JM60600-(X)CR***
RM25030-(X)CR
RM25060-(X)CR
RM25100-(X)CR***
RM25200-(X)CR***
RM25400-(X)CR***
RM25600-(X)CR***
RM60030-(X)CR
RM60060-(X)CR
RM60100-(X)CR***
RM60200-(X)CR***
RM60400-(X)CR***
RM60600-(X)CR***
HM25030-(X)CR
HM25060-(X)CR
HM25100-(X)CR***
HM25200-(X)CR***
HM25400-(X)CR***
HM25600-(X)CR***
HM60030-(X)CR
HM60060-(X)CR
HM60100-(X)CR***
HM60200-(X)CR***
HM60400-(X)CR***
HM60600-(X)CR***
CH30J(X) / (X)I
CH60J(X) / (X)I
CHCC(X)DU / (X)DIU
CHM(X)DU / CHM(X)DIU
Services and
application guide
Competitor
fuse family
1. Some competitor blocks are adder blocks and/or have multiple terminal offerings for
Cu/Al or Cu only conductors.
2. Wire ranges are not always the same. Please assure wire range is suitable
for the application.
3. All blocks listed have a box lug for wire termination. Alternate connection
types are available in the 30 and 60 amp range. If an alternate type is
required, please see the appropriate Eaton's Bussmann division data sheet for part
number ordering information.
Data sheets are available online at www.cooperbussmann.com/DatasheetsEle. For technical assistance, contact the Eaton Application Engineering
Team.Call 636-527-1270 between 7:00 AM and 5:00 PM Central Time, or e-mail FuseTech@eaton.com.
For customer assistance, call the Customer Satisfaction Team toll-free 855-BUSSMANN (855-287-7626) or e-mail BussCustSat@eaton.com.
BUSSMANN SERIES FULL LINE CATALOG
1007July 2015
Eaton.com/bussmannseries
16-19
16
Index
Catalog number index
Catalog
number
Page
Catalog
number
__NZ01
7-11
15HLE-PDM-_
5-15, 5-16
1BS1_ _ _
6-21, 6-93
3429
4410
__NZ02
7-11
15HLE-PNM-_
5-15, 5-16
1CIF
3434
4412
15LHLE-_E
5-15, 5-16
2004
3512
4413
10-7, 10-8
2081
3513
4421
9-57
10-7, 10-8
_AHLE-_E
5-13, 5-14
_BHCL-_E
5-8, 5-10
160___
_BHLE-_E
5-8, 5-10
162___
Page
Catalog
number
Page
Catalog
number
Page
Catalog
number
Page
21010
3515
4422
2127
3519
4423
10-7, 10-8
2178
3520
4427
170E_ _ _ _
2201
3521
4428
7-11
170F_ _ _ _
6-85
2245
3528
4482
_D27
7-11
170H_ _ _ _
6-92
2322
3531
4512
_D33
7-11
170L
13-14
3545
4513
_BS
7-20
163__
_CLE-_E
5-13
165___
_D125
7-11
_D16
_HCL-_E
_LSC
5-9, 5-14
170M_ _ _ _
24 Type
6-25 6-79
2429
3552
4514
7-20
170N
2430
3553
4515
9-57
7-12 7-14
170R
2432
3554
4520
9-56
170T
246B9949BG
3555
4522
13-14
175GDMSJD
2487
3556
4525
11239
9-41
175GXQNJD
2499
9-55
3562
4528
5-30
11240
9-41
1976
25499
3569
4529
5-30
11241
9-41
1A0065
2601
3571
4532
11242
9-41
1A0835
2604
3572
4535
11675-
10-7
1A1119-
4-12
2605
3575
4537
11725-
10-7
1A1120-
4-12
2607
3576
4561
_NHG _ _ _ B
1025
11 Type
11960
1A1310
2608
3578
4567
13195
1A1360
2610
3591
4574
9-55
1A1478
13926
2611
3594
4909
13-12
2650
3595
51215
1A1837
2654
3604
51235
13-12
1A1838
2698
3723
9-57
5591-
4-14
4-14
14002-
10-9
1A1706-_
14004-
10-9
15087
15100-_
13-8
1A1853
15149
12-47
1A1907-
15188-3
11-29
1A2294
15188-4
2714
3742
9-57
5592-
4-12
2772
3743
9-57
5623
2778
3823
5672-
4-14
5674-
4-14
11-29
1A3398-
4-12
2795
3828
9-56
15242
1A3399-
4-11
2834
3833
15288
11-29
1A3400-
2-8, 4-14
2837
3835
9-57
5681-
4-13
15595
1A3746
2838
3839
5682-
4-13
15600
1A4533-
4-12
2839
3959
5950
15602
1A4534-
4-12
2860
3998
5956-
15660
1A4708
2989
39E
5958
15800
13-6
1A4806
2992
4121
5960-
15900
1A5018-
4-11
2A066
4164
3-10
5961
15968
1A5600-
3-15
2A8
4164-FR
3-10
5ACLS-30
5-21, 5-22
15BHLE-_E
5-18, 5-19
1A5601-
4-11
2ACLS-25
5-20
4178
5BCLS-_R
5-21, 5-22
15CLE-_E
5-15, 5-16
1A5602-
4-11
2BCLS-_R
5-20
4180
5-30
5BCLS-30
5-21, 5-22
15CLE-_E-D
5-15, 5-16
1A5603
5-3, 5-4
4202
5CLE-_E
15CLE-GNM-_
5-15, 5-16
1A5778
3-15
2CLE-GMD-_
5-3, 5-20
4261
5CLE-_E-D
15CLE-GDM-C
5-15, 5-16
1A5779
3-15
2CLE-GNM-_
5-3, 5-20
4287
5CLE-GMD-_
5-5, 5-21
15CLE-HPDM-_
5-15, 5-16
1A5780
3-15
2CLE-PDM-_
5-3, 5-20
4386
5CLE-GNM-_
5-5, 5-21
15CLE-HPNM-C
5-15, 5-16
1A5940
2CLE-PNM-_
5-3, 5-20
4393
9-56
5CLE-PDM-_
5-5, 5-21
15CLE-PDM-_
5-15, 5-16
1A6049
2CLS-25
5-20
4399
5CLE-PNM-_
15CLE-PNM-_
5-15, 5-16
1A8654
2HCLS-_R
5-20
4402
5CLS-30
5-21, 5-22
15HCL-_E
5-18, 5-19
1B0048
2P25G
11-13
4405
9-55
5HCLS-_R
5-21, 5-22
15HLE-_E
5-15, 5-16
1B0049
3356
4406
9-55
5HCLS-30
5-21, 5-22
15HLE-GDM-D
5-15, 5-16
1BR021
3375
4407
5HLE-_E
15HLE-GNM-D
5-15, 5-16
1BR048
3411
4408
5HLE-GDM-_
2CLE-_E
5678
*
4-14
*
4-14, 5-30
*
5-5, 5-6
5-5, 5-6
5-5, 5-21
5-5, 5-6
5-21
* Not listed in this catalog. Call Eaton Customer Satisfaction for more information. Toll-free phone: 855-287-7626 (855-BUSSMANN)
16-20
1007July 2015
Eaton.com/bussmannseries
20
Index
Catalog number index
Catalog
number
Page
Catalog
number
5HLE-GNM-_
5-21
9835
5HLE-PDM-_
5-21
9838
Catalog
number
Page
Catalog
number
ATC
3-13
BPS_NPEIEC
ATC-_ID
3-13
BPSNPEIEC
5-21
5-21, 5-22
9841
ATC-FHID
3-13
BPSNPEWE
9843
ATF
15-6
A3354705
ATM
3-13
BQE
11-32
C4044
6125TD
A3354710
ATM-_ID
3-13
BQQ41
11-32
C4559
6374
A3354730
5-3, 5-7,
ATM-_LP
3-13
BRKT-_
11-16, 11-20
C515
4-2
63A-DUMMY
ATM-FHID
3-14
BRT
C517
4-2
6415
A3354720
ATR
3-15
BRW
C518
4-2
6417
A3354730
5-3
B221
8-8
BSPD_
14-5
C519
4-2
6418
A3354745
5-36
B222
8-8
BSPD_DIN_
14-60 14-62
C520
4-2
6419
A404302
BAC_
BSPD48RJ45
14-58 14-59
C5237
6420
AAO
BSPD5BNCD_
14-54 14-55
C5268-
3-4
ABC
BSPD5BNCSI
14-56 14-57
C5898
BSPG_NPE
14-32 14-33
C60BS
7-20
5HLE-PNM-_
5LCLS-_R
5TPH
64200
6422
6424
6427
Page
5-11, 5-20
ABCNA_
7-9
4-6
12-29,12-31, 12-33,
5-24, 5-25,
5-27, 5-28
ABC-V
ABGNA_
BPVM_
Page
Catalog
number
16
Page
14-33
C2909
14-35, 14-39
C30BS
7-20
14-51, 14-53
C30F
7-20
C30FBS
7-20
*
*
*
6-21
12-44
BSPH2-PV
14-40, 14-43
C60F
7-20
4-6
BAF
3-5
BSPH_TNS
14-38 14-39
C60FBS
7-20
BAN
BSPH_TT
14-34 14-35
C6344
7-9
BSPH_WE
14-48 14-49,
C7018
14-52 14-53
C7019
14-40 14-43
C7021-
64300
3-4
64913
ABS
BAO
64926
ABU
BB1P_ _
9-7 9-8
65372
ABWNA_
5-24, 5-25,
BB3P_ _
9-7 9-8
65398
5-26, 5-27,
BBS
68100
68300
3-4
68600
3-4
7 Type
70
*
11-43
C7024-
7-10
BBU-EFID
BSPM_ S2G
14-14 14-15
CAV_
ACB
BC (fuses)
7-10
BSPM_HLG
14-20 14-21
ACF
BC_(separator)
7-15
BSPM_S3G
14-16 14-17
13-14
ACH
BCC
BSPM_TN
14-32 14-35
13-12
ACK
BCF
BSPM_TNC
14-36 14-37
74 Type
13-14
ACL
BCM_
BSPM_WE
14-46 14-53
75 Type
13-15
ACO
BCPH2_PV
BSPM_WYG
14-18 14-19
CBB
76 Type
13-15
AD
BSPM_WYNG
14-20 14-21
CBC
80 Type
13-15
ADL
CBF
BSPM-DLG
14-18 14-19
CBP
BSPP
14-40 14-43
CBS
AC
7-10
*
BD (fuses)
BFW
8414677
ADLSJ
5-32
BG
8588A81H
ADOSJ
5-32
BGH
3-8
BSPH_YPV
9-32 9-33
14-40, 14-43
7-9
*
9-40
*
11-44
5-24, 5-25, 5-27,
5-28, 5-29
CAV_E
5-24, 5-26,
CAVH_E
5-24, 5-26,
5-28, 5-29
5-28, 5-29
8AHLE
5-13
AF
BHLE
5-18
BSPP_YPV
14-40 14-43
CBT
8BHLE
5-13
AFS
BH- _ _ _ _
6-93
BSPS_PV
14-40 14-43
CBU
8CLE-_E
5-11, 5-12
AFX
BH-_ xxx
6-21
BSPS_TN
14-26 14-27
CCB
8HLE-_E
5-11, 5-12
AGA
4-6
7-9 7-10,
BSPS_TNC
14-28 14-29
CCG
8CLE-_E-D
5-11, 5-12
AGC
4-7
9-41
BSPS_TNS
14-30 14-31
CCP-_
12-2
4-7
14-26 14-27,
CCPB-_
12-8
14-30 14-31
CCPLP-_
12-4
14-46 14-49
CCP-_-CF
12-6
8CLE-GDM-_
5-11
AGC-V
8CLE-GNM-_
5-11
AGU
8CLE-PDM-_
5-11
AGW
8CLE-PNM-_
5-11
AGX
8HCL-_E
5-13
AGX-V
8HLE-GDM-_
5-11
8HLE-GNM-_
BH-_(fuseblocks)
BMM_
9-32 9-33
BSPS_TT
11-32
4-6
BPG_NPE
14-33
BSPS_WE
4-6
BPG_NPEWE
14-47
C002-0101-_
11-11
CCSK-45
15-2
BPH_-D_LV
14-25
C002-0201
11-11
CD
7-10
AGY
BPH_YPV
14-40 14-43
C002-0301
11-11
CD100
5-11
ALS
7-16
CD27
8HLE-PDM-_
5-11
ALW
14-37
7-17 7-19
CDB
8HLE-PNM-_
5-11
AMG
C10G_
7-16
CDC
9078A67G04
5-3, 5-7,
AMI
14-21
C10M_
7-17 7-19
CDN
7-3
7-3
C08G_
C08M
C14G_
7-16
CDS
9435
ANL
3-10
14-53
C14M_
7-17 7-19
CEO
9483
ANN
3-10
14-40 14-43
C22G_
7-17
9732
ASZ350B3
BPMA_D_LV
14-23
C22M_
7-17, 7-19
9789
AT
BPP_SYPV
14-40
C2617
CH10CL
9834
AT512
C2791
CH10CM
5-11, 5-20
AMWNA_E
11-27
BPM_YPV
CFP-_
CGL
7-9
15-6
7-4
* Not listed in this catalog. Call Eaton Customer Satisfaction for more information. Toll-free phone: 855-287-7626 (855-BUSSMANN)
21
1007July 2015
Eaton.com/bussmannseries
16-21
Index by
part number
BNQ21
16
Catalog
number
Index
Catalog number index
Page
Catalog
number
Page
Catalog
number
Page
Catalog
number
Page
CH14
9-5
DOOR-508
12-36
F01A
CH22
9-5
DP100
11-4
F02A
FLM
GMD-V
CH30J_
9-5, 9-9
DP150
11-4
F02B
FLN
GMF
CH60J_
9-5, 9-9
DP230
11-4
F03A
FLRM
GMQ
CH8
9-2, 9-5
DP25
F03B
CHCC
9-2, 9-5
DP35
11-3
F09A
FLS
CHM
9-2, 9-5
DP45
11-3
F09B
FM
9-6
DP60
CH-PLC
CHPV
DRA-_
CIH
7-7
DRL_
CIK
7-7
CIL
7-7
DRLC-A
CJ
7-6
DS_
CL1
6-102
CLE
5-3, 5-8
12-20, 12-23
*
Page
GMD
4-5
4-5
3-12
3-11
GMT-_
13-13
GMW
6-98, 6-101
GND
12-36, 12-38
11-4
F10A
FM01A
GRF
3-12
11-21
F15A
FM08A
GSK-260
15-2
O-5
F16A
FM09A
GV_
9-12
F520
11-9
FM09B
H07C
7-8
F520DDST
11-9
FMM
6-98, 6-101
H12-_
F520ST
11-9
FMX
F520STLED
11-9
FNA
3-9
11-10
FNM
3-7
DPLT-_
CIF
12-20, 12-23
Catalog
number
F520T0P
11-17
F60C
FNQ
3-7
DS20
11-2
F61C
FNQ-R
1-8
DS30
11-2
F62C
FNW
DS50
11-2
F63C
FP-_
15-6
CLPT-_E
DSS_
11-2, 11-17
F64C
FRN-R
1-30
HAS-R
5-28, 5-29
DTST
11-11
F65C
FRN-R-__ID
1-30
HBC
5-24, 5-27
DTST2
11-11
FA02
FRS-R
1-31
HBH
4-10
5-24, 5-27
E-6188
FA2A
FRS-R-__ID
1-31
HBH-I
4-10
6-102
FA4H
FT-_
15-6
HBH-M
4-10
FBP
FTI
HBM
FC
FTM
HBO
6-98, 6-100
FCB
FWA
HBP-
EF
7-10
FCC
FWC
6-112
HBS-
11-18, 11-19
EFS
7-10
FCF
1-12
FWH
HBV-I
4-10
6-98, 6-99
ENA
CLPT-_E-A
CLPT-_E-B
CM__CF
CP14002
CS_
EC-_ _ _
ECAP_
ED
EET
9-7, 9-8
7-10
12-37
H79-_
FCU
FWJ
6-19, 6-120
HBV-M
4-10
ER1-_800L3PB
12-41
FDM
FWK
6-118
HBW-I
4-10
7-10
ER1-_J3PB
12-41
FE
6-98, 6-101
FWL
6-122
HBW-M
11-11
ER1-_N3SB
12-43, 12-45
FEE
6-98, 6-101
FWP
11-9
ER12-_J3PB
12-41
FEH
7-15
FWS
6-122
HCM
7-9
ER12-_N3SB
12-43, 12-45
FF
7-10
FWX
6-10, 6-106
HEB
9-46 9-47
6-5
9-45
HCL-NL-1
4-10
5-8, 5-13, E-18
ER12-800L3PB
12-41
FG
7-10
GBA
3-8
HEC
DG100
11-8
ER3R-_J3PB
12-41
FHL
GBB
4-7
HEF
DG150
11-8
ER3R-_N3SB
12-43, 12-45
FHN
GBB-V
4-7
HEG
9-45
DG230
11-8
ER3R-800L3PB
12-41
FL-
GBC
DG25
11-7
ER4-_J3JPB
12-41
FL11H_
5-33
GF
DG35
11-7
ER4-_N3SB
12-43, 12-45
FL11K_
5-33
GFA
DG60
11-7
ER4-800L3PB
12-41
FL11N
ER4P-_J3PB
12-41
ER4P-_N3SB
12-43, 12-45
DIA
DIR-_
HEH
9-45
7-10
HEJ
9-45
HET
9-45
GG
7-10
HEX
9-45
FL11T__
5-33
GH
7-10
HEY
9-45
FL12K__
5-33
GKB
13-12
HEZ
9-45
ER4P-800L3PB
12-41
FL1A5
GLD
3-8
HFA
9-44
ER4X-_J3PB
12-41
FL3H
GLN
HFB
9-43
12-37
ER4X-_N3SB
12-43, 12-45
FL3K__
5-33
GLP
7-20
HGA
12-41
FL3T__
E-33
GLQ
3-11
HGB
GLR
3-12
HGC
GLX
HHA
3-13
DIS10
DKNSPSDKSPS_
11-6
11-4, 11-16
11-3, 11-4, 11-6,
11-11, 11-16
ER4X-800L3PB
ERK-28
ERS2
ERS30
DM20
11-5
ESD
DM30
11-5
ET
DM50
11-5
ETF
15-3
*
FLB
FLC_
GMA
4-5
HHB
9-43
7-9
*
FLD
GMA-V
4-5
HHC
3-13
6-98, 6-99
FLF
GMC
4-5
HHCP
3-14
GMC-V
4-5
HHD
3-13
12-20, 12-23
FLH_
* Not listed in this catalog. Call Eaton Customer Satisfaction for more information. Toll-free phone: 855-287-7626 (855-BUSSMANN)
16-22
1007July 2015
Eaton.com/bussmannseries
22
Index
Catalog number index
Catalog
number
Page
Catalog
number
Page
Catalog
number
HHF
3-13
HRE
9-44
JM60100
9-17 9-21
KDT
3-4
LAN
HHG
3-13
HRF
9-44
JM60200
9-17 9-21
KDU
3-4
LAR
HHH
3-14
HRG
9-44
JM60400
9-17 9-21
KDY
3-4
LCT
6-95
HHL
3-14
HRH
9-44
JM60600
HHM
3-14
HRI
9-44
JN_
HHR
3-13
HRJ
9-44
HHS
3-13
HRK
9-43
HHT
9-44
HSK
HHX
3-14
HTB-
9-50 9-51
HIF
HJL
9-52
HJM
HKA
HKL
9-52
HTC-30M
HKP
9-49
HTC-35M
9-48
HKQ
HTC-40M
HKR
9-52
HKT
Page
Catalog
number
Page
Catalog
number
16
Page
9-17 9-21
KEF
LEF
11-25 11-31
KEM
LET
6-95
JNDN3
11-25
KER
LKB
JP600
9-31
KEW
3-4
LKC
JPA-3
KEX
3-4
LKN
KFH-A
3-4
LKS
JSK-36
15-2
HTC-140M
4-11
JT
9-14 9-15
KFM
3-4
LMMT
6-95
HTC-15M
4-11
JTN
9-14 9-15
KFT
3-4
LMT
6-95
HTC-200M
4-11
JU
KFZ
3-4
LP-CC
HTC-210M
4-11
K07C
1-7
7-8
KGC
LPJ__SP
1-19
KAB
KGJ
LPJ__SPI
1-19
KAC
6-14
KGJ-A
LPN-RK__SP
1-25
9-48
KAD
11-31
KGJ-E
LPN-RK__SPI
1-25
HTC-45M
4-9
KAD
KGL
LPRK-28
15-3
9-52
HTC-50M
4-9
KAF
KGO-E
LPS-RK__SP
1-25
HKU
9-52
HTC-55M
9-48
KAJ
KGS
LPS-RK__SPI
1-25
HKX
9-52
HTC-70M
9-48
KAL
KGS-A
LPT
HLD
9-52
HVA
5-30
KAW
KGT
LUG1-_
12-22, 12-31
HLQ
3-11
HVB
5-30
KAX
KGX
12-22, 12-31
HLQ-_
3-11
HVJ
5-30
KAZ
3-10
KIG
HLR
3-12
HVL
5-30
KBC
6-15
KIT-6POLE
HLS
13-13
HVR
5-30
KBD
HLT
13-13
HVT
5-30
KBJ
HM_
9-24 9-30
HVU
5-30
KBR
HM25100
HVW
5-30
KBT
HM25200
HVX
5-30
HM25400
HWA
HM25600
IXL70F
HM60100
J-_ _
HM60200
HM60400
HM60600
LUG2-_
3-4
LUG3-_
12-31
12-36, 12-38
LUG5-_
12-25, 12-33
KJA
LUG6-_
12-33
KLC
M09C
KLM
3-6
M14C
KLP
KBY
KLU
1-24
KCA
3-4
KMH-C
MAI
MAS
7-8
7-8
6-102
*
MAX-
3-14
KCB
3-4
KPF
3-4
MAX-__ID
3-14
15-7
KCC
3-4
KQO
3-4
MAX-FHID
3-14
J101/J
KCD
3-4
KQT
3-4
MB-
1-36
J201/J
KCE
3-4
KQV
3-4
MBO
J301/J
KCF
3-4
KQW-M
HME
9-44
J70032
6-123
KCH
3-4
KRP-C__SP
1-22
MCRW
HMF
9-44
J70100
6-123
KCJ
3-4
KRP-CL
1-23
MDA
4-8
HMG
9-44
JB1
KCM
3-4
KS-19392-L36
MDA-V
4-8
HMH
9-44
JCA
KCR
3-4
KT3
11-31
MDL
4-8
HMI
9-44
JCK-_R
5-20
KCS
3-4
KT4
11-31
MDL-V
4-8
HMJ
9-44
JCK-A-_R
5-20
KCV
3-4
KTK
3-5
MDM
HMK
JCL-_R
5-21, 5-22
KCY
3-4
KTK-R
1-9
MDQ
4-8
HMR
JCL-A-_R
5-21, 5-22
KCZ
3-4
KTN-R
1-28
MDQ-V
4-8
HN-1
JCM
KDA
3-4
KTN-S
HN-5
JCP
KDB
3-4
KTS-R
1-29
MIC
9-54
JCW-
5-24, 5-26
KDC
3-4
KTS-S
HPD
9-53
JCX-_E
5-3, 5-4
KDD
3-4
KTU
HPF
9-53
JCY-_E
5-5, 5-6
KDE
3-4
KU_(terminal blocks)
HPG
9-53
JF1
KDF
3-4
KWN-R
MFN
*
6-102
*
*
3-9
MIJ
1-24
MIS
3-10
11-42
MKB
MMT
6-98, 6-100
HPL
JJN-
1-32
KDH
3-4
L09C
7-8
MSK-45
HPM
9-54
JJS-
1-33
KDJ
3-4
L14C
7-8
MT
HPS
9-53
JKS
1-20
KDM
3-4
LAA
MT12
HPS2
9-54
JM_
9-24 9-30
KDP
3-4
LAC
MT12-1-2
HPV-
2-8, 2-9
JM60___-_MW_
9-22 9-23
KDR
3-4
LAG
MTC6
15-2
6-98, 6-100
*
11-25 11-32
11-25, 11-31
* Not listed in this catalog. Call Eaton Customer Satisfaction for more information. Toll-free phone: 855-287-7626 (855-BUSSMANN)
23
1007July 2015
Eaton.com/bussmannseries
16-23
Index by
part number
HPC-D
MC_ _ _
16
Catalog
number
Index
Catalog number index
Page
Catalog
number
Page
Catalog
number
NO.2664-R
15-7
PMP
NO.270
15-4
POLE-_
NO.36
15-3
POLE98-_
11-27
NO.4
15-5
PON
NBB
NO.5
15-5
PS
NBC
NO.6
15-5
PS1RPLSW
NBE
NO.616
15-7
PSU1
NC3
11-28
NO.616-R
15-7
PV-
MTMU
MV055F_
5-5, 5-7
MV155F_
5-15, 5-17
N512
NCLPT-_E
NCLPT-_E-A
Page
Catalog
number
Page
Catalog
numberCatalog
Page
Pagember
8-4, 8-5
SFC-_
15-6
12-43
SFD27
12-30
SFE
7-3
SFR
8-4, 8-5
SFR1
SH1-_
11-30
12-43
SH2-_
12-12
2-10
SH3-_
*
12-12
NO.626
15-7
PV-_01XL
2-14 2-16
SH4-_
5-24, 5-26,
NO.626-R
15-7
PV-_01XL15
2-16 2-18
SH5-_
5-27, 5-28
NO.642-R
15-7
PV-_10_
2-8
REG
NO.663
15-7
PV-10M-_
2-8
REN
SH6-_
ND-1260
NO.663-R
15-7
PV-_14F
2-10
RES
SH7-_
2-15
RFL
SH-GUIDE _
9-24 9-30
NDN1
11-26
NO.7
15-5
PV-_14LF
NDN111
11-26
NO.8
15-5
PV-_1XL
2-12 2-14
RM_
NDN3
11-25
NON
1-21
PV-_2XL
2-12 2-14
RK1SK-39
15-2
SKA
9-42
DTST2
11-11
NOS
1-21
PV-_2XL-15
2-16 2-18
RK5SK-39
15-2
SL-
1-34
NDNA
11-26
NPL
PV-_3L
2-12 2-14
RLA
9-46
SNL-7K
NRA
PV-_3L-15
2-16 2-18
RLC
I-46
SOU
9-42
NDNF1-WH
9-58
NSD
NDNFD1-WH
9-58
NSE3
11-28
PVCF
NDNLFD1-WH
9-58
NSS3
11-28
NDND1
NDNV4
11-25
NFA
NTN-R-_
NTQ23
7-9
15-7
11-32
PV-_NH1
2-11
RS_
SOW
9-42
RYA
9-46
SOX
9-42
PVM
2-4
RYC
9-46
SOY
PVS-R
2-7
S-
1-35
SPH50SP_PN
14-8 14-10
PWR1PLP
9-7 9-8
S500
4-3
SPH50SP_PNG
14-8 14-10
PWR35MM
9-7 9-8
S500-V
4-3
SPH50SP_SN
14-8 14-10
15-7
PWR50MM
9-7 9-8
S501
4-3
SPH50SP_SNG
14-8 14-10
S501-V
4-3
S505
4-3
S505H
4-4
SPH50SP_HLG
14-8 14-10
S505H-V
4-4
SPH50SP_DLG
14-8 14-10
Quik-Spec Coordination
S505-V
4-3
SPJ
9-10 9-11
Panelboards
S506
4-4
SPOD_
9-12 9-13
SPP
NTRL
NFT3
11-27
NTS-R-_
NFTA
NUE
QC202/J
NITD
7-9
NXA
QC203/J
NNB
15-7
NXC
NNB-R
15-7
OIA
NNC
15-7
OJ
NO.1
15-5
OPM-1038
OPM-NG
*
15-4
OSD
NO.2
15-5
P-
9-42
12-36, 12-38
11-27
NO.140
2-5, 2-6
NFT2
NO.100
8-7
8-2, 8-3
7-9
1-35
R11C
*
14-63 14-64
S506-V
4-4
8-6
S-8001
9-55
7-8
S-8002
9-55
SPP40SP_ PN
14-11 14-13
NO.201
P09C
7-8
S-8101
9-55
SPP40SP_ SN
14-11 14-13
NO.205
P11C
7-8
S-8102
9-55
NO.213
15-7
P20S
11-12
S-8201
9-55
SRD
NO.213-R
15-7
P25G
11-13
12-31
S-8202
9-55
SRT-A
NO.216
15-7
P30S
11-12
S-8203
9-55
SRU
NO.216-R
15-7
P65S
11-12
12-43
S-8301
9-55
SRU-BC
NO.220
15-4
PCB
RD16_
SA-
1-36
SRW
9-42
NO.226
15-7
PCC
SAMI-
9-16
SRX
9-42
NO.226-R
15-7
PCD
12-43
SB_-S
2-12
SRY
9-42
NO.242-R
15-7
PCF
RD25_
SC
1-18
SSD
7-9
NO.2621
15-7
PCG
RD30_
SCV15
SSN
9-42
NO.2621-R
15-7
PCH
RD40_
SCV20
SSU
9-42
NO.263
15-7
PCI-
RD400_
SCY
9-42
SSW
9-42
NO.263-R
15-7
PCT
13-13
SD_
2-11, 7-15
SSX
9-42
NO.2641
15-7
PDB___
10-2, 10-4
12-43
SD_-D-PV
2-11
SSY
9-42
NO.2641-R
15-7
PDBFS___
10-2, 10-3
SD_-SK
7-15
STD
7-9
NO.2642
15-7
PLK3
11-31
12-43
SDL_
7-15
STI
NO.2661-R
15-7
PLU1
11-30
RD63_
SF25H
STM
NO.2662-R
15-7
PLU3
11-29
RD80_
SFB1030
STY
9-42
12-35 12-37
* Not listed in this catalog. Call Eaton Customer Satisfaction for more information. Toll-free phone: 855-287-7626 (855-BUSSMANN)
16-24
1007July 2015
Eaton.com/bussmannseries
*
*
9-42
*
Index
Catalog number index
Catalog
number
T-
Page
Catalog
number
1-35
Page
Catalog
number
Page
TPL-_
13-10
WKU
T30__
9-36 9-37
TPM
13-3
WKV
T60__
9-36 9-37
TPMDS
13-3
WLF
13-11
WMB
TB100-
11-33
TPN-_
TB200-
11-35
TPS
13-6
WMM
TB300-
11-37
TPSFH-_
15-6
WMQ
TB345-
11-27
TPWDS
WPQ
TB400-
11-41
TRF
WQN
WQP
TSH_-_
TC
1-35
TCF
1-10
WSE
TCF__RN
1-10
WSH
TCFH_N
1-16
TVSS-
WSL
TCFH_NW
1-16
TXLEJ
5-32
WSM
TXMEJ
5-32
WSQ
TD_-D
7-15
TXQEJ
5-32
WST
TD00_
7-15
UHA
3-4
WSU
TDC
UHC
WTJ
TDC10
UHJ-M
3-4
WTK
TDC11
UHJ-T
3-4
WTT
TDC180
UHJ-W
3-4
WTZ
TDC600
UHS
WUE
TDLEJ
5-32
UHT
WUG
TDLSJ
5-32
UHW
WUH
TDMEJ
5-32
ULR
WUI
TDQSJ
5-32
VFNHA
5-31
WUQ
TFC
VKNHA
5-31
WUR
TFF
W-
1-34
WUU
TFL
WCF__RN
1-14
WUV
TCP
TFLSJ
5-32
WDFHO
5-31
WUW
TFMEJ
5-32
WDLSJ
5-31
WUY
TFQSJ
5-32
WDOH6
5-31
WVA
WDOSJ
5-31
WVQ
13-14
WVR
TGH
THLEJ
5-32
WER
THMEJ
5-32
WFFHO
5-31
WWD
TI_
6-102
WFLSJ
5-31
WWE
TIQ
WFMSJ
5-31
WWG
TJD
WFNHO
5-31
WWI
TKLEJ
5-32
WFOH6
5-31
WWK
TKMEJ
5-32
WFOSJ
5-32
WWU
TL-
1-34
WGA
WWV
WHA
WWX
11-21 11-24
WHN
WYM
WIE
WZC
5-31
WZJ
WZK
5-31
WZX
TM2_
TP158HC
13-7
TP15900
WJON6
13-4
WKB
TP15914
13-5
WKFHO
TPA
13-5
WKH
XL25X
TPA-B
13-5
WKJ
XL50F
TPB
WKK
TPC
13-2
WKL
TPCDS
13-2
WKLSJ
5-32
WKMSJ
5-31
13-9
WKNHO
5-31
TPH
TPHCS-_
TPJ
WKS
Page
Catalog
number
Page
Index by
part number
TP15900-4_
Catalog
number
16
* Not listed in this catalog. Call Eaton Customer Satisfaction for more information. Toll-free phone: 855-287-7626 (855-BUSSMANN)
1007July 2015
Eaton.com/bussmannseries
16-25
16
Notes
Notes
16-26
1007July 2015
Eaton.com/bussmannseries
Low-Peak upgrade
LP-CC
LP-CC
Class L
Class J
Existing fuse
A4J
AJT
CJ
CJS
GF8B
HRCXXJ
J
JA
JCL
JDL
JFL
JHC
JKS
JLS
JTD
Low-Peak
LPJ_SP
upgrade
LPJ_SP
Existing fuse
A4BQ
A4BT
A4BY
A4BY (type 55)
CLASS L
CLF
CLL
CLU
HRC-L
KLLU
KLPC
KLU
KTU
L
LCL
LCU
Low-Peak upgrade
LPN-RK_SP
Low-Peak upgrade
KRP-C_SP
KRP-C_SP
Low-Peak upgrade
LPS-RK_SP
LPS-RK_SP
LPN-RK_SP
The comparative catalog numbers shown were derived from the latest available published information from various manufacturers.
Because competitors products may differ from Bussmann series products, it is recommended that each application be checked for required
electrical and mechanical characteristics before substitutions are made. Eaton is not responsible for misapplications of our products.
Overcurrent protection is application dependent. Consult the latest catalogs and application literature, or contact our Application
Engineering Department toll free at 855-287-7626 (855-BUSSMANN).
Our focus is on delivering the right solution for the application. But,
decision makers demand more than just innovative products. They turn
to Eaton for an unwavering commitment to personal support that makes
customer success a top priority.
At Eaton, thats how were powering business worldwide.
My.Eaton.com:
Application engineering:
1-800-468-1705 Option #3
for log-in assistance.
Toll-free phone:
855-287-7626 (855-BUSSMANN)
E-mail: Fusetech@eaton.com
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Bussmann Division
114 Old State Road
Ellisville, MO 63021
United States
Eaton.com/bussmannseries
2015 Eaton
All Rights Reserved
Printed in the USA
Publication No. 1007
July 2015