Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
New
Direct Operated Poppet Type
[Option]
RoHS
Power consumption
4w
1.8 w
Standard type
Vacuum
applications
101.2
kPa
Energy-saving type
(Existing product: 2 W)
54.5
N.O. valve
Divider valve
Selector valve
etc.
Series
VT307
29.5
33.2
Manifold type
CAT.ES11-107A
Series
VT307
Vacuum
specification type
Energy-saving type
+
Vacuum
specification type
Energy-saving type
Application examples
q Blow-off valve
w Pressure release
valve
e Selector valve
(P)1
(P)1
2(A)
P1 (P)1
2(A)
(R)3 X
Plug
(R)3
y Single-acting
cylinder drive
(P)1
(P)1
Tank
(R)3
u Double-acting
cylinder drive
N.O.
2(A)
2
(A)
1
(P)
(R)3
3
(R)
Vacuum pad
N.C.
2(A)
2(A)
(R)3
P2 (R)3
Tank
t Divider valve
2(A)
1
(P)
N.C.
2(A)
2(A)
3
(R)
1
(P)
N.C.
2(A)
3
(R)
1
(P)
3
(R)
New
VT307
0.19
VT317
0.62
Features 1
VT325
1.4
http://www.smcworld.com
VP300/500/700
0.8 to 3.6
Series VT307
Rubber Seal
RoHS
[Option]
Note) CE compliant: Electrical entry is
applicable only for the DIN
terminal.
How to Order
V T 307
5 G
1 01
Body type
T
O
Body ported
For manifold
CE-compliant
Valve option
Nil
E
Y
V
W
Nil
Q
Standard type
Continuous duty type
Energy-saving type
Vacuum specification type
Energy-saving type, Vacuum specification type
Bracket
Nil
F
Semi-standard
Pressure specifications
Nil
K
Nil
F
N
T
Semi-standard
Rated voltage
100 VAC, 50/60 Hz
200 VAC, 50/60 Hz
110 VAC, 50/60 Hz
220 VAC, 50/60 Hz
24 VDC
12 VDC
240 VAC, 50/60 Hz
Semi-standard
Electrical entry
Grommet
DIN terminal
None
With bracket
Thread type
1
2
3
4
5
6
7
None
CE-compliant
Rc
G
NPT
NPTF
Port size
Nil
01
02
None
With surge voltage suppressor
(Grommet type only)
With light/surge voltage suppressor
(DIN terminal type only)
D: With connector
JIS Symbol
(A)2
(R)3
1(P)
Manifold
Model
Accessories
Function plate (DXT152-14-1A) Note)
Mounting screw (NXT013-3)
Note) It is not applicable to the continuous duty type. Refer to the accessories
on page 5.
Option
Description
Bracket
Part no.
DXT152-25-1A (With screw)
Series
VT307
Standard Specifications
Caution
Make sure that dust and/or other foreign
materials do not enter the valve from the
unused port (e.g. exhaust port).
Flow-rate Characteristics/Weight
Valve model
Port
size
VT307
VT307V (Vacuum spec. type)
VT307E (Continuous duty type) 1/8
VT307Y (Energy-saving type)
VT307W (Energy-saving, Vacuum spec. type)
VT307
VT307V (Vacuum spec. type)
VT307E (Continuous duty type) 1/4
VT307Y (Energy-saving type)
VT307W (Energy-saving, Vacuum spec. type)
AC (50/60 Hz)
DC
Semi-standard
Note 1) Based on dynamic performance test, JIS B 8374-1981. (Coil temperature: 20C, at rated voltage,
without surge voltage suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction
and at the right angles to the main valve and armature in both energized and
de-energized states every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 1000 Hz. Test
was performed at both energized and de-energized states in the axial direction
and at the right angles to the main valve and armature. (Values at the initial
period)
Note 3) At rated voltage
Note 4) The value is different for continuous duty type (VT307E), and energy-saving type (VT307Y/W).
Refer to Valve Options shown below.
1 2 (P A)
C[dm3/(sbar)]
b
Cv
Flow-rate characteristics
2 3 (A R)
3 2 (R A)
C[dm3/(sbar)]
b
Cv C[dm3/(sbar)]
b
Cv
2 1 (A P)
C[dm /(sbar)]
b
Cv
3
0.71
0.35
0.18
0.68
0.27
0.17
0.65
0.36
0.17
0.63
0.35
0.17
0.41
0.26
0.10
0.44
0.35
0.11
0.48
0.27
0.12
0.35
0.33
0.10
0.71
0.31
0.19
0.71
0.25
0.17
0.68
0.33
0.17
0.71
0.26
0.18
0.49
0.20
0.12
0.44
0.34
0.11
0.48
0.17
0.12
0.46
0.28
0.11
Weight
Grommet
0.15 kg
Note) Values for a single valve unit. It is not applicable to the manifold. Refer to the manifold specifications on page 5.
Valve Options
Continuous duty type: VT307E
Caution
1. This model is for continuous duty, not for
high cycle rates. But even in low cycle
rates, if energizing the valve more than
once a day, please consult with SMC.
2. Energizing solenoid should be done at
least once in 30 days.
Caution
Since this valve has slight air leakage, it can
not be used for vacuum holding (including
positive pressure holding) in the pressure
container.
Specifications different from standard are as follows.
Energized
Manual override
VT307
Caution
Light/Surge Voltage Suppressor
Construction
De-energized
Series
AC
r
y
u
Terminal no. 2
DC
q
Terminal no. 1 (+)
()
()
()
()
e
()
<Energized>
Operation principle
<De-energized>
Port
Component Parts
Description
Body
Poppet valve
Return spring
Molded coil
Terminal no. 2 ()
()
No.
1
2
3
4
Coil
Material
Aluminum die-casted
Aluminum, HNBR
Stainless steel
Resin
When energizing the molded coil r, the armature t is magnetically attracted to the core y,
and through the push rod u, it pushes down the
poppet valve w and port is closed. Then, port
and port are connected. At this time, there
will be gaps between the armature t and the
core y, but the armature t will be magnetically
firmly attracted to the core y.
Air flow direction:
Port , Port
Block
Port
2. Wiring
1) Pass the cable u through the cable gland r,
plain washer t and rubber seal y in this order,
and then insert them into the housing w.
2) Loosen the screw !1 attached to the terminal
block e. Then, pass the lead wire !0 through the
terminal block e and tighten the screw !1 again.
Note 1) Tighten within the tightening torque of
0.5 Nm 15%.
Note 2) Cable u outside diameter: 6 to 8 mm
Note 3) Crimped terminal like round-shape or
Y-shape cannot be used.
Note
Color: White
Terminal no.
DIN terminal
1 2
+
Ground
Electrical Connection
DIN terminal is connected inside as in the
figure below. Connect to the corresponding
power supply.
3. Assembly
1) Pass the cable u through the cable gland r,
plain washer t and rubber seal y in this order
and connect to the terminal block e. Then, mount
the terminal block e on the housing w.
(Push it down until you hear the click sound.)
2) Put the rubber seal y and plain washer t in this
order into the cable entry of the housing w, and
then tighten the cable gland r securely.
3) Insert the gasket i between the bottom part of
terminal block e and the plug attached to the
equipment. Then, screw in q from the top of the
housing w to tighten it.
Note 1) Tighten within the tightening torque of 0.5
Nm 20%.
Note 2) Connector orientation can be changed
180 depending on how the housing w
and the terminal block e are assembled.
Voltage
100 VAC
200 VAC
DC
Others
Color
Blue
Red
Red (+), Black ()
Gray
q
w
y
t
Part no.
B1B09-2A (Standard)
DIN connector
GM209NJ-B17 (CE-compliant)
e
u
i
!1 o !0
Series
VT307
Dimensions
Grommet: VT307-G1
(33)
(17.2)
2 x 4.5
(For mounting)
(14.5)
(4.5)
(42)
Manual override
(Non-locking)
(4.5)
(28)
(37)
13.5
10.3
54.5
13
47.2
G: 300
H: 600
(Lead wire length)
40.3
(3.2)
25.6
16.5
16.7
29.5
18.6
33.2
1/4", 1/8"
(Piping port)
25
65
Applicable cable O.D.
6 to 8
(17.2)
(14.5)
(28)
Max. 10
(4.5)
2 x 4.5
(For mounting)
(37)
13.5
10.3
16.5
33.2
18.6
25.6
(3.2)
13
54.5
Pg9
25
1/4", 1/8"
(Piping port)
16.7
29.5
67.6
(33)
56
(4.5)
(42)
Manual override
(Non-locking)
Series VT307
Manifold Specifications
VT307 manifold is available
both as a common exhaust
and individual exhaust
model.
VV307 01 05 2
01
F
Mounting bracket
Dummy symbol
Manifold valve can be easily converted from N.C. (Normally Closed) to
N.O. (Normally Open) merely by turning over the function plate.
Thread type
VT307 manifold
Nil
F
N
T
Valve stations
02 2 stations
20 20 stations
Max. 20 stations
01
02
18
Common exhaust
VV307-01-052--F
Rc
G
NPT
NPTF
Common exhaust
Individual exhaust
Manifold Specifications
Manifold type
Max. number of stations
Applicable solenoid valve
Exhaust port
Type
Symbol
Individual exhaust
VV307-01-053--F
Common
Individual
B mount
20 stations Note)
VO307- (-Q)
P
Base (Side)
18
18
18
Base (Side)
Base (Side)
1 8, 1 4
Base (Top)
14
18
Note) For 6 stations or more, supply air both sides of P port. The common exhaust type should exhaust from
both of the R port.
Option
Description
Blanking plate (With gasket, screw) Note)
Part no.
A
DXT060-51-13 B
Part no.
A
DXT152-14-1 B
NXT013-3
Qty.
1 pc.
2 pcs.
Flow-rate Characteristics/Weight
Valve model
VO307
VO307V (Vacuum spec. type)
VO307E (Continuous duty type)
VO307Y (Energy-saving type)
VO307W (Energy-saving, Vacuum spec. type)
1 2 (P A)
C[dm3/(sbar)]
b
Cv
Flow-rate characteristics
2 3 (A R)
3 2 (R A)
C[dm3/(sbar)]
b
Cv C[dm3/(sbar)]
b
Cv
2 1 (A P)
C[dm3/(sbar)]
b
Cv
0.34
0.28
0.089
0.34
0.22
0.082
0.36
0.28
0.091
0.34
0.18
0.080
0.30
0.18
0.070
0.30
0.15
0.072
0.32
0.20
0.075
0.30
0.15
0.069
Weight
Grommet
0.15 kg
Series
VT307
G: 300
H: 600
56.7
VV307-01-2-01-F
Pg9
Grommet (G, H)
111
50.6
43.5
9
1/8"
[1(P), 3(R) port]
18
L2
L1
13
20
13
(Station 1)
64
40
1/8"
[2(A) port]
(Pitch)
P = 26
23
(35)
77.1
Max. 10
(Station n)
19
20
38
29
21.6
26.7
(Pitch)
P = 26
12
39.3
For 4 x M4
(For mounting)
4.6
83
Manual override
(Non-locking)
31
L Dimension
n
L1
L2
2
88
62
n: Stations
Formula
114 140 166 192 218 244 270 296 L1 = 26 x n + 36
88 114 140 166 192 218 244 270 L2 = 26 x n + 10
10
Series
VT307
G: 300
H: 600
55.2
25
Pg9
1/8"
[3(R) port]
(Pitch)
P = 26
12
50.6
43.5
39.3
19
1
18.5
(Station 1)
31
40
62.5
75.6
Max. 10
(Station n)
1/4"
[1(P) port]
28.5
L2
L1
20
11
29
(1)
38
27
21.6
4.6
83
For 4 x M4
(For mounting)
111
Manual override
(Non-locking)
1/4", 1/8"
[2(A) port]
(Pitch)
P = 26
22
L Dimension
n
L1
L2
2
76
64
n: Stations
Formula
102 128 154 180 206 232 258 284 L1 = 26 x n + 24
90 116 142 168 194 220 246 272 L2 = 26 x n + 12
10
Series VT307
Mounting
Warning
Caution
When mounting a valve on the manifold base, N.C. and N.O. can
be reversed by the function plate orientation. Also, since the
cylinder operates in reverse, confirm if the function plate is
correctly mounted or not.
N.C.
specification
N.O.
specification
Port z
Port x
Port c
Function plate
Figure: For N.C.
Function plate
Specifications
N.C.
N.O.
Caution
1. Each valve is fixed to the manifold base with two M4 mounting
screws. Tighten the screws firmly when re-mounting.
2. For mounting, tighten M4 or equivalent screws evenly into the
mounting holes of the manifold base.
Tightening torque of the mounting screw (M4): 1.4 Nm
Function plate
No mark
NO
Piping
Caution
1. For the common exhaust type, pressurization or evacuation of
the 3(R) port can cause a malfunction.
Safety Instructions
Caution:
Warning:
Danger :
Caution
Warning
1. The compatibility of the product is the responsibility of the
person who designs the equipment or decides its specifications.
Since the product specified here is used under various operating conditions, its
compatibility with specific equipment must be decided by the person who designs
the equipment or decides its specifications based on necessary analysis and test
results. The expected performance and safety assurance of the equipment will be
the responsibility of the person who has determined its compatibility with the
product. This person should also continuously review all specifications of the
product referring to its latest catalog information, with a view to giving due
consideration to any possibility of equipment failure when configuring the
equipment.
Compliance Requirements
1. The use of SMC products with production equipment for the manufacture of
weapons of mass destruction (WMD) or any other weapon is strictly prohibited.
2. The exports of SMC products or technology from one country to another are
governed by the relevant security laws and regulations of the countries involved
in the transaction. Prior to the shipment of a SMC product to another country,
assure that all local rules governing that export are known and followed.
Safety Instructions Be sure to read Handling Precautions for SMC Products (M-E03-3) before using.
D-G
P1569-1636-E.qxd
08.9.2 4:01 PM
Page 1609
Series VT317
Rubber Seal
[Option]
How to Order
Compact yet provides a large
flow capacity
Dimensions (W x H x D)45 x 89.5 x 45
(Grommet)
C: 2.6 dm3/(sbar)
(Passage 2 3)
V T 317
02
Body type
Body ported
Manifold
T
0
Thread type
101.2 kPa
(For vacuum specifications: VT/VO317V)
Rc
G
NPT
NPTF
Nil
F
N
T
Valve option
Nil
Standard type
E Continuous duty type
V
For vacuum
VQD
CE-compliant
Nil
100
200
110 VAC,50 60
220 VAC,50 60
24 VDC
12 VDC
240 VAC,50 60
Other
CE-compliant
Q
Electrical entry: D/DO
only
Rated voltage
1
2
3
4
5
6
7
9
Hz
Hz
Hz
Hz
VKF
VK
VT
Hz
VS
Port size
Nil
Option
02
Without port
(For manifold)
1 4 (8A)
Electrical entry
G
H
C
T
D
V100
S070
Option
VAC,50 60
VAC,50 60
VV061
Symbol
Nil
S
Z
JIS Symbol
Note)
Note)
Note)
Manifold
Model
VO317(-Q)
Accessory
O-ring (P10, 4 pcs.) Note)
Bolts (M4 x 0.7 x 20, 2 pcs.)
Note) It is not applied to Continuous duty type. Refer to the accessories on page 1612.
1609
P1569-1636-E.qxd
Series
08.9.2 4:01 PM
Page 1610
VT317
Standard Specifications
Direct operated type 2 position single solenoid
Air
0 to 0.9 MPa
10 to 50C (No freezing. Refer to page 5.)
30 ms or less (at the pressure of 0.5 MPa)
10 Hz
Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)
Non-locking push type
Unrestricted
150/50 m/s2
Dustproof
Type of actuation
Fluid
Operating pressure range
Ambient and fluid temperature
Response time (1)
Max. operating frequency
Lubrication
Manual override
Mounting orientation
Shock/Vibration resistance (2)
Enclosure
Grommet, Conduit,
Conduit terminal, DIN terminal
100, 200, 110 , 220 , 240
AC (50/60 Hz)
Coil rated voltage (V)
24, 12
DC
15 to +10% of rated voltage
Allowable voltage fluctuation
19 VA (50 Hz), 16 VA (60 Hz)
Inrush
Apparent power (3)
AC
Holding
11 VA (50 Hz), 7 VA (60 Hz)
Without indicator light: 6 W, With indicator light: 6.3 W
Power consumption (3)
DC
Varistor, Neon bulb
AC
Light/Surge voltage suppressor
(Not applicable for grommet type)
DC
Varistor, LED (Neon bulb for 100 V or more)
Electrical entry
Option
Note 1) Based on dynamic performance test, JIS B 8374-1981. (Coil temperature: 20C, at rated voltage,
without surge suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction
and at the right angles to the main valve and armature in both energized and
de-energized states every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 1000 Hz. Test
was performed at both energized and de-energized states in the axial
direction and at the right angles to the main valve and armature. (Values at
the initial period)
Note 3) At rated voltage
Flow Characteristics/Mass
Valve model
VT317
VT317V (Vacuum spec. type)
VT317E (Continuous duty type)
1 2 (P A)
C [dm3/(sbar)]
b
Cv
2.4
0.26
0.62
Flow characteristics
2 3 (A R)
3 2 (R A)
C [dm3/(sbar)]
C [dm3/(sbar)]
b
Cv
b
Cv
2.6
0.34
0.67
2.8
0.25
0.67
2 1 (A P)
C [dm3/(sbar)]
b
Cv
2.5
0.37
0.66
Mass
Grommet
0.29kg
Note) Values for a single valve unit. It differs in the manifold case. Refer to manifold specifications on page 1612.
Option
Construction
De-energized
Exclusive
use
of VT317E
is
recommended for continuous duty
with long time loading.
Energized
Caution
1. This model is for continuous duty, not for
high cycle rates. But even in low cycle
rates, if energizing the valve more than
once a day, please consult with SMC.
2. Energizing solenoid should be done at
least once in 30 days.
Caution
1. Since this valve has slight air leakage,
it can not be used for vacuum holding
(including positive pressure holding) in
the pressure container.
Specifications different from standard
are as follows.
Operating pressure range 101.2 kPa to 0.1 MPa
1610
Operation principles
<De-energized>
<Energized>
Component Parts
No.
1
2
Description
Body
Spool valve
Note
Material
Aluminum die-casted Color: Platinum silver
Aluminum, NBR
P1569-1636-E.qxd
08.9.2 4:01 PM
Page 1611
Series
VT317
!
,
"
+ "
" -.
(
( ) # $
* " $
#+
#$
%
&'
( (0
!
,
"
+ "
" -.
#$
%
&'
( ) # $
* " $
#+
!
"
"
!
"
"
VV061
V100
S070
) 6+
( ) # ) , / $
) 6+
( ) # ) , / $
VQD
VKF
VK
VT
( ) # $
* " $
#+
!
,
"
+ "
" -.
) 6+
!
"
"
( ) # ) , / $
#$
%
&'
) 6+
12
,&
$"
( ) # $
* " $
#+
#)
!
,
"
+ "
" -.
#$
%
&'
VS
!
"
"
( ) # ) , / $
3""
&/
&/
4 1
5 5(
P1569-1636-E.qxd
08.9.2 4:01 PM
Page 1612
Series VT317
Manifold Specifications
How to Order Manifold
VT317 manifold is B mount
style and available both as
a common exhaust and
individual exhaust model.
VV317
02
05
02
Option
Base type:
1/4
VV317-02-051-02-A
Thread type
Nil
F
N
T
VT317 manifold
Rc
G
NPT
NPTF
Common exhaust
type only
02 2 stations
Symbol
Common
exhaust
Valve
stations
Mounting bracket
20 20 stations
Max. 20
Symbol
1
3
VV317-02-051-02
Passage
P
R
Common Common
Common Individual
Porting specifications
A
Side
Side
Manifold Specifications
B mount
20 stations (1)
VO317-(-Q) (3)
Manifold type
Max. number of stations
Applicable solenoid valve
Exhaust port
Type
Symbol
VV317-02-053-02
Individual
exhaust
Common (2)
Individual
14
14
14
Note 1) For more than 3 stations, supply air both sides of P port. The common exhaust type should
exhaust from both of the R port.
Note 2) In the case of common exhaust type, R and P ports size can be Rc 3/8 by using a mounting
adaptor.
Note 3) Can also be applied to Series VVT320 manifold.
Part no.
P10
P10F
Max. 0.7 x 20
Qty
Note
Standard type vacuum specifications type
Continuous duty type
4
2
Option
Description
Blanking plate (With screw, O-ring)
Mounting bracket (With screw)
Part no.
PVT317-53-1A
DXT010-37-4
(For common exhaust)
Flow Characteristics/Mass
Valve model
VO317
VO317V (Vacuum spec. type)
VO317E (Continuous duty type)
1612
1 2 (P A)
C [dm3/(sbar)]
b
Cv
2.0
0.11
0.47
Flow characteristics
2 3 (A R)
3 2 (R A)
C [dm3/(sbar)]
C [dm3/(sbar)]
b
Cv
b
Cv
2.2
0.12
0.49
2.0
0.14
0.45
2 1 (A P)
C [dm /(sbar)]
b
Cv
3
2.1
0.14
0.48
Mass
Grommet
0.32kg
P1569-1636-E.qxd
08.9.2 4:01 PM
Page 1613
Series
VT317
% + .!
'
/ 0!-!
1)23+4
VV061
5
V100
5
S070
! ! "#$# % %
VQD
L Dimension
L1
L2
2
10
5
! ! "#$# % %
L Dimension
L1
L2
2
VK
VT
VS
% + .!
/ 0!-!
1)23+4
5
VKF
10
P1569-1636-E.qxd
Series
08.9.2 4:01 PM
Page 1614
VT317
1 /
)#)$ 23
+
&4(005!55!
=
$ " #
' #
425
' 45
: # 4:5
;+ #
4;5
;+ #
&*
$ .,' 4
5
0
%#'#
4
3 *9
$5
>
<..*(# *(# ; = =
!
, ) &
)$
-
) .' /
) %
((
. $
) 0$#
+
!"#
$ %%#
"#
& '
(#) "#
$ #
'#*'#' +&
#'
"# ,
$
'#*
) *
#*#' #-.#
/
&
*
0
(/ #&#
$
" , ,*" %# &
.#*&*
"
#$ %
%
#&$' ( &' %$ ! )
)
)
)) &$ *
7%#
1" . /.#
#"
," , 0
$ *#, 2$"#
+
'%' #"
* "
$
$ &
2" . '* '#%##' %%# +& %%#
##'#') # %#
$ *#, & "#
#-#' %%#
'
"# %%#
8 '#$## 409# # " "## # 3
$ &#'
.
& "# %%# &*#5 2"#
) $"#
"#
$ *#, & "# %%# "#
& '
(#
P1569-1636-E.qxd
08.9.2 4:01 PM
Page 1615
Series VT317
Caution
Caution
(1)
(2)
(4)
(3)
VV061
V100
Manual
override
S070
Coil
VQD
Varistor
VKF
Surge voltage
suppressor (S)
Coil
AC
Varistor
VT
Coil
DC Diode
VK
VS
Bleed port
of main valve
Neon bulb
Light/Surge voltage
suppressor (Z)
Varistor
None
48 VDC or less
100 VDC
Neon bulb
DC
Varistor
Coil
Varistor
Coil
AC
Coil
Bleed air
passage
Protection circuit for light/surge voltage suppressor is not the polarity type.
Color
Blue
Red
Red (+), Black ()
Gray
Electrical Connection
DIN terminal is connected inside as in the figure
below. Connect to the corresponding power supply.
Ground
1615
P1569-1636-E.qxd
08.9.2 4:01 PM
Series
Page 1616
VT317
How to Use DIN Terminal
1. Disassembly
1) After loosening the thread (1), then if
the cover (4) is pulled in the direction of
the thread, the connector will be
removed from the body of equipment
(solenoid, etc.).
2) Pull out the screw (1), then remove the
gasket (2a) or (2b).
3) On the bottom part of the terminal block
(3), theres a cut-off part (indication of
an arrow) (3a). If a small flat head
screwdriver is inserted between the
opening in the bottom, terminal block
(3) will be removed from the cover (4).
(Refer to graph at right.)
4) Remove the cable gland (5) and plain
washer (6) and rubber seal (7).
2. Wiring
1) Pass them through the cable (8) in the
order of cable ground (5), washer (6),
rubber seal (7), and then insert into the
housing (4).
2) Dimensions of the cable (8) are as
shown in the right figure. Skin the cable
and crimp the crimped terminal (9) to
the edges.
3) Remove the screw with washer (3e)
from the bracket (3e). (Loosen in the
case of Y-shape type terminal.) As
shown in the right figure, mount a
crimped terminal (9), and then again
tighten the screw (3e).
Note) Tighten within the tightening
torque of 0.5 Nm 15%.
Note: a It is possible to wire even in the
state of bare wire. In that case,
Exploded
view
(1)
(4)
(7)
(5)
(6)
(3e)
(3b)
(3d)
(3c)
(3)
(9)
(3a)
(3e)
(8)
(9)
(3e)Magnifying
figure
(2a)
Self-up screw
2
1
3
(2b)
Comparison between the Product Model No. and the Coil Part No.
Product model no.
Coil assembly with terminal part no.
Coil no.
VT/O317-G(-02)
PVT317-001GB-
VT/O317-GS(-02)
PVT317-G
VT/O317-H(-02)
PVT317-001GB-L06
VT/O317-HS(-02)
PVT317-G-06
VT/O317-C(-02)
PVT317-001CB-
VT/O317-CS(-02)
PVT317-C
PVT317-001TBT-
VT/O317-T(-02)
PVT317-001TBTS-
VT/O317-TS(-02)
PVT317-001TBTZ-
VT/O317-TZ(-02)
PVT317-001DBT-
VT/O317-D(-02)
PVT317-001DB-
PVT317-001DBTS-
VT/O317-DS(-02)
PVT317-001DB-
PVT317-001DBTZ-
VT/O317-DZ(-02)
PVT317-001DB-
Note 1) mark in the product model numbers denotes the rated voltage.
Note 2) mark denotes the valve option.
Note 3) mark and mark are for coil part number and coil assembly with terminal the rated voltage.
Example 1) In the case of VT317-001GB-05
Example 2) In the case of PVT317-5G
Note 4) In the case of CE-compliant products (-Q), coils are not shipped together.
Caution
When the rated voltage is AC and if it is assembled with the coil for DC, response may be delayed and occur malfunction. Also, for DC valves, when the
coil for AC is assembled, it occurs malfunction. For AC valves, assemble the coil for AC, and for DC valves, assemble the coil for DC.
100 VAC
200 VAC
24 VDC
GDM2A
GDM2A-S1
GDM2A-S2
GDM2A-S5
GDM2A-Z1
GDM2A-Z2
GDM2A-Z5
1616
P1569-1636-E.qxd
08.9.2 4:01 PM
Page 1617
Series VT325
Rubber Seal
[Option]
How to Order
02 1 G
VT325
Manual override
For manifold:
Enter VO.
Valve option
Nil
Standard
V For vacuum
Option
14
38
00
Without connection
port (For manifold)
Rc
G
NPT
NPTF
Nil
Q CE-compliant
Electrical entry:
D/DO/DL/DLO only
Electrical entry
G
Rated voltage
101.2 kPa
(For vacuum specifications type: VT/VO325V)
Nil
F
N
T
CE-compliant
Port size
02
03
Thread type
C
D
T
TL
DL
Grommet,
Lead wire length
300 mm
Conduit
DIN terminal
Conduit terminal
Terminal with
indicator light
DIN terminal with
indicator light
Manifold
VT325-T
Model
Applicable manifold
VO325-00(-Q)
Accessory
Gasket (DXT083-13-1)
Bolts (DXT083-19-1, 2 pcs.)
Specifications
VT325-D
VT325-C
VT325-G
JIS Symbol
Type of actuation
Fluid
Operating pressure range
Ambient and fluid temperature
Max. operating frequency
Response time (1)
Lubrication
Manual override
Shock/Vibration resistance (2)
Enclosure
Note 1) Based on dynamic performance test, JIS B 8374-1981. (Coil temperature: 20C, at rated voltage, without
surge suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the
right angles to the main valve and armature in both energized and de-energized states
every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 1000 Hz. Test was performed
at both energized and de-energized states in the axial direction and at the right angles to the main
valve and armature. (Values at the initial period)
Solenoid Specifications
Electrical entry
Coil rated voltage
Allowable voltage fluctuation
Inrush
Apparent power (3)
AC
Holding
DC
V100
S070
VQD
None
With surge voltage
suppressor
VV061
1617
VKF
VK
VT
VS
P1569-1636-E.qxd
Series
08.9.2 4:01 PM
Page 1618
VT325
Flow Characteristics/Mass
Valve model
Port size
VT325
VT325V (Vacuum spec. type)
VT325
VT325V (Vacuum spec. type)
Flow characteristics
1 2 (P A)
2 3 (A R)
3 2 (R A)
2 1 (A P)
C [dm3/(sbar)]
b
Cv C [dm3/(sbar)] b
Cv C [dm3/(sbar)] b
Cv C [dm3/(sbar)] b
Cv
1/4
5.5
0.37
1.4
5.9
0.35
1.5
5.5
0.33
1.4
5.7
0.32 1.4
3/8
5.5
0.37
1.4
6.1
0.37
1.6
5.7
0.34
1.4
6.6
0.25 1.5
Mass
Grommet
0.55 kg
(For AC)
0.60 kg
(For DC)
Note) Values for a single valve unit. It differs in the manifold case. Refer to manifold specifications on page 1620.
Option
Construction
1. For vacuum
Pressure range
De-energized
101.2 kPa to 0.1 MPa
Energized
u Plunger
w Cover
y Coil
Caution
1) Since this valve has slight air leakage,
it can not be used for holding vacuum
(including positive pressure holding) in
the pressure container.
i Over travel
assembly
q Body
e Spool valve
Conduit
terminal
(TS)
Varistor
o Retainer
Operation principle
<De-energized>
The spool e is pushed upward by the force
of the spring r and the air passage
between port x and port c is opened and
port z is blocked.
Air flow direction: z
Block, x
c
Coil
DC
Varistor
Coil
Coil
AC
DIN terminal
Neon
with indicator light bulb
(DL)
Conduit terminal
Neon
with indicator light
bulb
(TL)
Grommet type
Surge voltage suppressor
1618
t O-ring
r Spool spring
Coil
()
Black
Diode
Red
(+)
Coil
Varistor
DC
Coil
AC
Grommet
(GS)
Conduit
(CS)
<Energized>
When the coil y is energized the plunger u
is pulled down depressing the spool e via
the overtravel assembly i and the air
passage between port z and port x is
opened and port c is blocked.
Air flow direction: z
x, c
Block
Component Parts
No. Description
Material
1 Body
Aluminum die-casted
2 Cover
Aluminum die-casted
3 Spool valve
Aluminum, NBR
Note
Platinum silver
Platinum silver
P1569-1636-E.qxd
08.9.2 4:01 PM
Page 1619
Series
VT325
Dimensions
Grommet (G)
Conduit (C)
Manual override
(Non-locking)
Manual override
(Non-locking)
2 x mounting
groove
200
2 x mounting
groove
3 x Rc 1/4, 3/8
VV061
V100
3 x Rc 1/4, 3/8
Width across flats
S070
VQD
VKF
DIN terminal (D)
Applicable cable O.D.
6 to 12
Manual override
(Non-locking)
VK
Connector
VT
VS
2 x mounting
groove
2 x mounting
groove
3 x Rc 1/4, 3/8
Light
2 x mounting
groove
3 x Rc 1/4, 3/8
Width across flats
1619
P1569-1636-E.qxd
08.9.2 4:01 PM
Page 1620
Series VT325
Manifold Specifications
How to Order Manifold
Series VT325 Manifold
Model has a B mount style
with common exhaust.
VVT34 0
05 1
Porting
specifications
Thread type
Port size
Symbol
P
A
R
0
Side Side Side
1
Side Bottom Side
Valve
stations
17
17 stations
Rc
G
NPT
NPTF
Common exhaust
2 stations
02
Nil
F
N
T
Manifold Specifications
Manifold type
Max. number of stations
Applicable solenoid valve
Common exhaust
B mount
17 stations Note)
VO325-00(-Q)
Option
Port direction
A
P
Side
Side/Bottom
R
Side
DXT083-21A
Note) If there are more than 4 stations, supply air from both P ports and exhaust from both R ports.
Part no.
DXT083-13-1
DXT083-19-1
Qty.
1 pc.
2 pcs.
Flow Characteristics/Mass
Valve model
1 2 (P A)
C [dm3/(sbar)]
b
Cv
Flow characteristics
2 3 (A R)
3 2 (R A)
C [dm3/(sbar)]
b
Cv
C [dm3/(sbar)]
b
Cv
2 1 (A P)
C [dm /(sbar)]
b
Cv
3
VO325
VO325V
(Vacuum spec. type)
4.1
0.24
1.0
4.4
0.18
1.0
4.5
0.15
1.0
4.3
0.23
1.0
Mass
Grommet
0.58 kg
(For AC)
0.63 kg
(For DC)
Precautions
Warning
When mounting valves on the manifold
base, the mounting orientation is decided.
If it is mounted in the wrong direction,
connected equipment may malfunction.
Mount it by referring to external
dimensions on page 1621. Besides, the
external dimensions are showing the case
of N.C. specifications.
1620
Caution
Changing from N.C. to N.O.
The valves are assembled as N.C. valves
at the time of shipment.
By removing the two retaining screws
from the desired valves, and rotating each
valve body 180 and reassembling it on
the manifold base, it is possible to
reassemble an N.C. valve as an N.O.
valve. (When doing so, make sure that a
gasket is attached to the mounting
surface of the valve.) Properly tighten the
screws.
The tightening torque of the retaining
screws is 3 Nm.
P1569-1636-E.qxd
08.9.2 4:01 PM
Page 1621
Series
VT325
Dimensions
Common exhaust
Pitch
2 x 9 mounting
hole
Conduit
terminal (T)
DIN
terminal (D)
Grommet (G)
Conduit (C)
Max. 2
4 x Rc 1/4, 3/8
n x Rc 1/4, 3/8
Pitch
Bottom ported
VV061
Port (1)
A, Port (2)
Port (3)
Pitch
V100
S070
VQD
VKF
n x Rc 1/4, 3/8
n: Stations
n
Symbol
L1
L2
2
131
111
3
177
157
4
223
203
5
269
249
6
315
295
7
361
341
8
407
387
9
453
433
10
499
479
1621
VK
VT
VS
P1569-1636-E.qxd
08.9.2 4:01 PM
Page 1622
Series VT325
Caution
Bleed
groove
Bleed port
on main valve
Electrical Connection
For wiring to DIN terminal, connect the
positive (+) polar side with connector
terminal no. 1 and the negative () side
with connector terminal no. 2 when the
rated voltage is DC type.
1. Disassembly
1) After loosening the thread (1), then if
the cover (4) is pulled in the direction
of the thread, the connector will be
removed from the body of equipment
(solenoid, etc.).
2) Pull the screw (1), and then remove
gasket (2a) or (2b).
3) On the bottom part of the terminal
block (3), theres a cut-off part
(indication of an arrow) (3a). If a
small flat head screwdriver is
inserted between the opening in the
bottom, terminal block (3) will be
removed from the cover (4).
(Refer to the figure below.)
4) Remove the cable gland (5) and
plain washer (6) and rubber seal (7).
2. Wiring
1) Pass them through the cable (8) in
the order of cable ground (5), washer
(6), rubber seal (7), and then insert
into the housing (4).
2) Dimensions of the cable (8) are the
figure as below. Skin the cable and
crimp the crimped terminal (9) to the
edges.
3) Remove the screw with washer (3e)
from the bracket (3e). (Loosen in the
case of Y shape type terminal.) As
shown in the below figure, mount a
crimped terminal (9), and then again
tighten the screw (3e).
Note) Tighten within the tightening
torque of 0.5 Nm 15%.
Note: a It is possible to wire even in
the state of bare wire. In that
case, loosen the screw with
washer (3e) and place a lead
wire into the bracket (3d),
and then tighten it once
again.
b The maximum size for the
round terminal (9) is 1.25
mm23.5 and for the Y
terminal is 1.25 mm24.
c Cable (8) external: 6 to 12
Note) For the one with the external
dimension ranged between 9
to 12 remove the inside parts
of the rubber seal (7) before
using.
1622
Part no.
GDM2C
3. Assembly
1) Terminal box (3) connected with
housing (4) should be reinstated.
(Push it down until you hear the click
sound.)
2) Putting rubber seal (7), plain washer
(6), in this order into the cable
introducing slit on the housing (4),
then further tighten the cable gland
(5) securely.
3) By inserting gasket (2a) or (2b)
between the bottom part of the
terminal box (3) and a plug on an
equipment, screw in (1) on top of the
housing (4) and tighten it.
Note) Tighten within the tightening
torque of 0.5 Nm 20%.
Note: The orientation of a connector
can be changed arbitrarily,
depending on the combination
of a housing (4) and a terminal
box (3).
Exploded view
(1)
(4)
(7)
(5)
(6)
(3d)
(3d)
(3)
(3a)
(3e)
(3e)
(3c)
(9)
(8)
(9)
(3e)Magnifying
figure
(2a)
2
1
3
(2b)
Self-up screw