Product Data Sheet

Edition 13/07/2007
Identification no:
02 05 01 07 004 0 000001
Sika Boom-G

(Template for local translation, only for internal use)

Sika Boom-G

Construction

1-part, highly expansive, gun applied polyurethane fixing foam


Product
Description

Sika Boom-G is a one part, highly expansive polyurethane fixing foam applied with
the Sika Boom-G Dispenser gun.

Uses

Sika Boom -G is used for fixing, insulating and filling connection joints around
window and door frames, around air-conditioning vents and roller blind housings
etc. It is also used for insulation against sound, cold and draughts etc.

Characteristics /
Advantages

High expansion rate


Easy application with the Sika Boom-G Dispenser Gun
Suitable for application at lower temperatures (+5C)
Fast curing
Excellent temperature insulation
Effective sound dampening
Age resistant
CFC / HFC-free

Product Data
Form
Colour

Light yellow

Packaging

500 ml can (12 cans per box)


750 ml can (12 cans per box)

Storage
Storage Conditions /
Shelf Life

9 months from date of production if stored in undamaged original sealed containers,


in dry conditions and protected from direct sunlight at temperatures between +18C
and +20C.
The aerosol cans must be stored in a vertical position!
An opened can must be used within ~ 4 weeks.

Technical Data
Chemical Base

1-part Polyurethane, moisture curing

Density

3
0.018 - 0.024kg/l (= 18-24 kg/m )

Skinning Time

9 2 minutes (+23C / 50% r.h.)

Curing Rate

A 20 mm bead of expanded foam can be cut after 30 minutes (+23C / 50% r.h.).
Full cured after 12 hours (+23C / 50% r.h.).

Sika Boom-G

1/3

Service Temperature

-30C to +80C (temporary up to +100C)

Heat Conductivity

~ 0.0405 W/mK

(DIN 52 612)

Mechanical / Physical
Properties
Compressive Strength
Shear Strength

2
~ 0.06 + 0.02 N/mm with 10% deformation (+23C / 50% r.h.)
2

~ 0.04 + 0.02 N/mm (+23C / 50% r.h.)


2

(DIN 53 421)
(DIN 53 427)

Tensile Strength

~ 0.09 N/mm (+23C / 50% r.h.)

(DIN 53 430)

Elongation at Break

~35% + 5% (+23C / 50% r.h.)

(DIN 53 430)

System
Information
Application Details
Consumption

Consumption can be regulated by adjusting the pressure valve of the Sika

Boom -G Dispenser gun.


Yield:
750 ml can up to 48 l (+/- 3 l)
500 ml can up to 32 l (+/- 3 l)

Substrate Quality

Clean and dry, homogeneous, free from oils and grease, dust and loose or friable
particles.

Substrate Preparation

Pre-dampen the substrate with clean water, this ensures that the foam cures
optimally and also prevents secondary foam expansion later on.

Application
Conditions /
Limitations
Substrate Temperature

+5C min. / +35C max. (aerosol can has to be +5C min.)

Ambient Temperature

Optimum handling temperature: +18C to +25C


Permissible handling temperatures: +5C min. / +35C max.

Substrate Moisture
Content

Has to be dry for visual control.

Relative Air Humidity

Between 30% and 100%

Application
Instructions
Application Method /
Tools

Shake the can thoroughly before use (~ 20 times). Remove the small black lid from

the Sika Boom -G aerosol can. Screw the Sika Boom -G can on to the Sika

Boom -G Dispenser. Gently press the trigger of the Sika Boom-G Dispenser to
apply the foam. Where small gaps have to be filled use the extension tube supplied
(the foam flow rate is lower with the extension tube). Take care to allow each layer
to cure sufficiently by spraying water or allowing sufficient waiting time between the
layers. Do not fill up hollow sections completely as the foam expands by 1.5 to 2
times its volume during curing! All fixings and components etc must be temporarily
supported until the foam has hardened.
Do not take the Sika Boom-G can off of the Sika Boom-G Dispenser unless
absolutely necessary. Taking the can off of the Sika Boom-G Dispenser, without

thorough cleaning with Sika Boom Cleaner, can lead to premature curing and nonfunctioning of the Sika Boom-G Dispenser. The safest way is to keep the Sika

Boom -G can mounted onto the Sika Boom -G Dispenser until empty.

Cleaning of Tools

Remove fresh spots of foam immediately using a cleaner such as Sika Boom

Cleaner / Sika Remover-208. Cured foam can only be removed mechanically.

Sika Boom-G

2/3

Notes on Application /
Limitations

The aerosol can temperature has to be +5C min. and +25C max. For optimum
flow and expansion the aerosol can temperature should be +18 to +25C.
Protect the can from direct sun and temperatures above +50C (danger of
explosion).
For the correct curing of the foam sufficient moisture is necessary.
Do not use on PE, PP, Teflon, Silicone, Oil, Grease and other separating agents.
Foam is not resistant to UV light.

Construction

Read the safety and technical recommendations printed on the aerosol-can.

Value Base

All technical data stated in this Product Data Sheet are based on laboratory tests.
Actual measured data may vary due to circumstances beyond our control.

Local Restrictions

Please note that as a result of specific local regulations the performance of this
product may vary from country to country. Please consult the local Product Data
Sheet for the exact description of the application fields.

Health and Safety


Information

For information and advice on the safe handling, storage and disposal of chemical
products, users shall refer to the most recent Material Safety Data Sheet containing
physical, ecological, toxicological and other safety-related data.

Legal Notes

The information, and, in particular, the recommendations relating to the application


and end-use of Sika products, are given in good faith based on Sika's current
knowledge and experience of the products when properly stored, handled and
applied under normal conditions in accordance with Sikas recommendations. In
practice, the differences in materials, substrates and actual site conditions are such
that no warranty in respect of merchantability or of fitness for a particular purpose,
nor any liability arising out of any legal relationship whatsoever, can be inferred
either from this information, or from any written recommendations, or from any other
advice offered. The user of the product must test the products suitability for the
intended application and purpose. Sika reserves the right to change the properties
of its products. The proprietary rights of third parties must be observed. All orders
are accepted subject to our current terms of sale and delivery. Users must always
refer to the most recent issue of the local Product Data Sheet for the product
concerned, copies of which will be supplied on request.
It may be necessary to adapt the above disclaimer to specific local laws and
regulations. Any changes to this disclaimer may only be implemented with
permission of Sika Corporate Legal in Baar.

Sika Services AG
Tffenwies 16
CH-8048 Zurich
Switzerland

Phone
+41 44 436 40 40
Telefax +41 44 436 46 86
wwww.sika.com

Sika Boom-G

3/3

Potrebbero piacerti anche