Sei sulla pagina 1di 2

JU6H-UF50

INSTALLATION & OPERATION DATA (I&O Data)


USA Produced
Basic Engine Description
Engine Manufacturer
Ignition Type
Number of Cylinders
Bore and Stroke - in (mm)
Displacement - in (L)
Compression Ratio
Valves per cylinder
Intake
Exhaust
Combustion System
Engine Type
Fuel Management Control
Firing Order (CW Rotation)
Aspiration
Charge Air Cooling Type
Rotation, viewed from front of engine, Clockwise (CW)
Engine Crankcase Vent System
Installation Drawing
Weight - lb (kg)

John Deere Co.


Compression (Diesel)
6
4.19 (106) X 5 (127)
415 (6.8)
17.0:1
1
1
Direct Injection
In-Line, 4 Stroke Cycle
Mechanical, Rotary Pump
1-5-3-6-2-4
Turbocharged
None
Standard
Open
D536
1657 (752)

Power Rating
Nameplate Power - HP (kW)

1760
183 (137)

2100
210 (157)

2350
210 (157)

Cooling System - [C051127]


Engine Coolant Heat - Btu/sec (kW)
Engine Radiated Heat - Btu/sec (kW)
Heat Exchanger Minimum Flow
60F (15C) Raw H20 - gal/min (L/min)
95F (35C) Raw H20 - gal/min (L/min)
Heat Exchanger Maximum Cooling Raw Water
Inlet Pressure - psi (bar)
Flow - gal/min (L/min)
Typical Engine H20 Operating Temp - F (C)[1]
Thermostat
Start to Open - F (C)
Fully Opened - F (C)
Engine Coolant Capacity - qt (L)
Coolant Pressure Cap - lb/in (kPa)
Maximum Engine Coolant Temperature - F (C)
Minimum Engine Coolant Temperature - F (C)
High Coolant Temp Alarm Switch - F (C)

1760
79 (83.4)
41 (43.3)

2100
90 (95)
48 (50.6)

2350
101 (107)
48 (50.6)

14 (53)
18 (68.1)

17 (64.3)
21 (79.5)

21 (79.5)
26 (98.4)

Electric System - DC
System Voltage (Nominal)
Battery Capacity for Ambients Above 32F (0C)
Voltage (Nominal)
Qty. Per Battery Bank
SAE size per J537
CCA @ 0F (-18C)
Reserve Capacity - Minutes
Battery Cable Circuit, Max Resistance - ohm
Battery Cable Minimum Size
0-120 in. Circuit Length[2]
121-160 in. Circuit Length[2]
161-200 in. Circuit Length[2]
Charging Alternator Maximum Output - Amp,
Starter Cranking Amps, Rolling - @60F (15C)

60 (4.1)
40 (151)
180 (82.2) - 195 (90.6)
187 (86.1)
196 (91.1)
19.5 (18.5)
10 (68.9)
200 (93.3)
160 (71.1)
205 (96.1)
Standard
12
12
1
8D
1375
430
0.0012
00
000
0000
40
440

Optional
24
[C07633]

[C07639]
[RE69704/RE70404]

24
2
8D
1375
430
0.0012
00
000
0000
40
250

[C07633]

[C071048]
[C07819/C07820]

NOTE: This engine is intended for indoor installation or in a weatherproof enclosure. 1Engine H2O temperature is dependent
on raw water temperature and flow. 2Positive and Negative Cables Combined Length.
Page 1 of 2

JU6H-UF50
INSTALLATION & OPERATION DATA (I&O Data)
USA Produced
Exhaust System
Exhaust Flow - ft./min (m/min)
Exhaust Temperature - F (C)
Maximum Allowable Back Pressure - in H20 (kPa)
Minimum Exhaust Pipe Dia. - in (mm)[3]
Fuel System
Fuel Consumption - gal/hr (L/hr)
Fuel Return - gal/hr (L/hr)
Fuel Supply - gal/hr (L/hr)
Fuel Pressure - lb/in (kPa)
Minimum Line Size - Supply - in.
Pipe Outer Diameter - in (mm)
Minimum Line Size - Return - in.
Pipe Outer Diameter - in (mm)
Maximum Allowable Fuel Pump Suction Lift
with clean Filter - in H20 (mH20)
Maximum Allowable Fuel Head above Fuel pump, Supply or Return - ft (m)
Fuel Filter Micron Size
Heater System
Engine Coolant Heater
Wattage (Nominal)
Voltage - AC, 1 Phase
Part Number

1760
924 (26.2)
1124 (607)
30 (7.5)
5 (127)

2100
1204 (34.1)
1034 (557)
30 (7.5)
5 (127)

2350
1359 (38.5)
977 (525)
30 (7.5)
5 (127)

1760
2100
10.7 (40.5)
12.3 (46.6)
5.8 (22)
6.9 (26.1)
16.5 (62.5)
19.2 (72.7)
3 (20.7) - 4 (27.6)
.50 Schedule 40 Steel Pipe
0.848 (21.5)
.375 Schedule 40 Steel Pipe
0.675 (17.1)

2350
12.9 (48.8)
7.9 (29.9)
20.8 (78.7)

31 (0.8)
4.5 (1.4)
5
Standard

Optional

1500
115 (+5%, -10%)
[C124948]

1500
230 (+5%, -10%)
[C124949]

Air System
Combustion Air Flow - ft./min (m/min)
Air Cleaner
Part Number
Type
Cleaning method
Air Intake Restriction Maximum Limit
Dirty Air Cleaner - in H20 (kPa)
Clean Air Cleaner - in H20 (kPa)
Maximum Allowable Temperature (Air To Engine Inlet) - F (C)[4]

130 (54.4)

Lubrication System
Oil Pressure - normal - lb/in (kPa)
Low Oil Pressure Alarm Switch - lb/in (kPa)
In Pan Oil Temperature - F (C)
Total Oil Capacity with Filter - qt (L)

40 (276) - 60 (414)
20 (138)
220 (104) - 245 (118)
21.1 (20)

Lube Oil Heater


Wattage (Nominal)
Voltage
Part Number

Optional
150
120V (+5%, -10%)
C04430

Performance
BMEP - lb/in (kPa)
Piston Speed - ft/min (m/min)
Mechanical Noise - dB(A) @ 1m
Power Curve

1760
198 (1370)
1467 (447)
C13915
C13480

1760
2100
314 (8.9)
433 (12.3)
Standard
[C03396]
Indoor Service Only, with Shield
Washable
12 (3)
6 (1.5)

2350
508 (14.4)
Optional
[C03327]
Canister, Single-Stage
Disposable
10 (2.5)
5 (1.2)

Optional
150
240V (+5%, -10%)
C04431
2100
191 (1320)
1750 (533)

2350
171 (1180)
1958 (597)

3
Based on Nominal System. Back pressure flow analysis must be done to assure maximum allowable back pressure is not exceeded. (Note:
minimum exhaust Pipe diameter is based on: 15 feet of pipe, on 90 elbow, and a silencer pressure drop no greater than one half of the maximum
allowable back pressure.) 4Review for horsepower derate if ambient air entering engine exceeds 77F (25C). [ ] indicates component reference part
number.

Page 2 of 2
C13508 Rev R
LDE 26OCT10

Potrebbero piacerti anche