Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
OVERVIEW
OVERVIEW
Architecture
TRADITIONAL
PABX
PABX
Analog
Private Automatic
Branch Exchange
Proprietary Phone
Fax
Architecture
ADVANCED
TELEPHONY
WIDE PHONE
TERMINAL
SECURITY
PLATFORMS
CONTACT
CENTER
UNIFIED
COMMUNICATION
RICH HOTEL
FEATURES
INTERNET
ACCESS
VOIP SERVICE
CONTINUES
INNOVATIONS
MOBILITY
SOLUTION
APPLICATION
OPENNESS
Via XML
Architecture
TOPHOLOGY Environment
Cabinets
Boards
12 ports
1 CPU slot + 1 MIX slot
Power consumption: 1.5 A (240 V)
Dimensions: H = 345 mm; W = 370 mm; D = 65
mm. Weight: 5.1 kg.
Cabinets
Boards
Cabinets
Boards
- The RACK S module (formerly known as RACK 1) mainly consists of a plastic frame The plastic frame receives all the parts for attaching the power supply board, the
fans, the battery and the mains power connector, and everything. -There is no
backplane board: the metric connectors are on the power supply module. -19" rack
modules which can be mounted in a rack or placed on a shelf - it has 3 slots 1 for CPU
& 2 for card interfaces
28 ports
1 CPU slot + 2 general-purpose slots (no SLI16
board) Power consumption: 1 A (230 V) / 2 A (110 V)
- 80 W. Dimensions: H = 66 mm (2.6 inches);
W = 442 mm (17,4 inches); D = 400 mm (15.76
inches). Weight: 6 kg.
Cabinets
Boards
Cabinets
Boards
-The enclosure consists of a metal top part, two metal side parts and a plastic front face
Access to the fans, the power supply module and the batteries is gained by
disconnecting the power cable and unscrewing the backplane.
-IIt has 6 Slots 1 for CPU & 5 for card interfaces
56 ports
1 CPU slot + 5 general-purpose slots
Power consumption: 1.2 A (230 V) / 2.3 A (110 V)
- 120W.
Dimensions: H = 110 mm (4.3 inches);
W = 442 mm (17.4 inches); D = 400 mm (15.76
inches). Weight: 11 kg.
Cabinets
Boards
RACK L (LARGE)
- 96 ports
- 1 CPU slot + 4 specific general-purpose
slots (no UAI16 and MIX boards)
- Power consumption: 1.2 A (230 V) / 2.3 A (110 V) -150
W. - Dimensions: H = 154 mm (6.1 inches)
W = 442 mm (17.4 inches); D = 400 mm (15.76
inches). -Weight: 13 kg.
- It has 9 slots, 1 for CPU & 8 for card interfaces
RACK XL (LARGE)
Cabinets
Boards
Cabinets
Boards
Daughter Boards
Cabinets
Boards
Cabinets
Boards
CPU-4
CPU Module
Mix Connector
SATA HD Connector
AFU -x
CPU-4
Available functions:
- LAN: 10/100 base T Ethernet port (MDI-II/straight)
- AUDIO-OUT: loudspeaker, alarm and general bell interfaces; 12V output AUDIO-IN: please-wait message and background music interfaces DOORPHONE: door phone interfaces
- CONFIG: RS232 for MMC, NMC and PPP connections
- MODULE1: HSL link to add-on module 1 (if HSL daughter board present) - MODULE2: HSL link to add-on
module 2 (if HSL daughter board present) - ISDN T0 1: T0 access 1 if Mini-Mix daughter board present
(CPU-3m or CPU-4 only) - ISDN T0 2: T0 access 2 if Mini-Mix daughter board present (CPU-3m or CPU-4
only) - SLI1/2: access to analog terminals 1 and 2 (if Mini-Mix daughter board present on CPU-3m or CPU4)
Cabinets
Boards
CPU-4
Cabinets
Boards
POWER CPU
The Power CPU board, based on processor Power Quicc II Pro MPC8377
from Free scale, has the following characteristics:
-667 MHz processor, 256 MB DDR2 SDRAM, SD/MMC Memory card
(2GB), -VoIP DSP C6421/4 (16 VoIP channels).
The Power CPU board is built around 2 main blocks interconnected via
PCI:
-CPU part with MPC8377 processor and following interfaces:
DDR 2 memory
BOOT (NOR Flash)
Serial ATA for Hard Disk
SD card controller PCI
LAN interfaces
I2C
Cabinets
Boards
POWER CPU
Cabinets
Boards
POWER CPU
Cabinets
Boards
AFU-1 (Auxiliary Function Unit): supporting auxiliary functions such as general bell,
door- phone, audio In, audio Out, etc. The AFU-1 board is required for the connection of
the ISDN-EFM box (T0/S0 forwarding)
MINI-MIX - Supports a combination of 2 SLI ports or 1 SO & 1 TO, or 1 SLI & 1 TO
SATEX RoHS board- connects the HD SATA to POWER CPU Module
POWER CPU
Cabinets
Boards
POWER CPU
Output Port
Available functions:
- LAN: 10/100/1000 base T Ethernet port (MDI-II/straight).
- SLI1/SLI2: Analog Z accesses from Mini-MIX board, General ringer; 12V
output -AUX: General ringer; 12V output
-- MODULE1: HSL1 link of HSL board for connection to module expansion
1 - ISDN T01: ISDN T01 port of Mini-MIX board
- MODULE2: HSL2 link of HSL board for connection to module expansion
2 - ISDN T02: ISDN T02 port of Mini-MIX board
- AUDIO: Interfaces Please wait message, Background music, Loudspeaker,
Alarm - DOORPHONE: Interfaces doorphone
Cabinets
Boards
POWER CPU
POWER CPU Front Panel
Output Port
Cabinets
Boards
POWER MEX
Cabinets
Boards
-The Power MEX board is a controller board for extension or module expansion.
-The Power MEX board (POWER Module EXPANSION) performs the controller
functions in the expansion platforms.
-The Power MEX board is equipped with an HSL1 (High Speed Link) board
for interconnecting with the basic platform.
- The Power MEX board is connected to the MODULE 1 or MODULE 2 connector
on the Power CPU board
Meaning of the LED Indications
Cabinets
Boards
The BRA board The BRA (Basic Rate Access) board provides the basic access points (2 x
64-Kbps B-channels + 1 x 16-Kbps D-channel per access) for connecting the system to the
ISDN digital public network (point-to-point or multipoint T0 link)starting with version
R2.0,
to a private network (point-to-point DLT0 link); 3 versions are offered:
Types:
- BRA2: 2 T0 accesses
- BRA4: 4 T0 accesses
- BRA8: 8 T0 accesses
Connection Diagram
Cabinets
Boards
The PRA board (Primary Rate Access) board provides 1 primary access for connecting the
Alcatel-Lucent Omni-PCX Office Communication Server system to the ISDN digital public
network or to private networks.
Types:
PRA -T2, DASS2, DLT2: 30 x 64-Kpbs B-channels + 1 x 64-Kbps D-channel; 2048
Kbps PCM R2: 30 x 64 Kbps B-channels + 1 x 4 Kbps signaling channel; 2048 Kbps.
OUTPUT PORTS (FACEPLATE)
Connection Diagram
T2 board example
Cabinets
Boards
Cabinets
Boards
APA Boards
This board is used to connect to the analog public network ( 4 or 8 ports).
Types:
- APA 4
- APA 8
Connection Diagram
Cabinets
Boards
SLI - xx-1
The SLI, SLI-1 or SLI-2 board (Single Line) allows the connection of 2-wire
analog terminals (Z). 3 board versions are available:
Types:
- SLI4: 4 Z interfaces SLI8: 8 Z interfaces SLI16: 16 Z interfaces
Connection Diagram
Cabinets
Boards
UAI - xx-1
The UAI board allows the connection of digital stations (UA). The UAI-16 board
allows to remotely supply the terminals connected to the 16 interfaces from a EPS48
external power supply connected to interface 1 using an external adaptation power
cable (splitter).
Types:
- boards without external power supply
capability: UAI4: 4 UA interfaces
UAI8: 8 UA interfaces
UAI16: 16 UA interfaces
- boards with external power supply
capability: UAI16-1: 16 UA interfaces
Connection Diagram
Cabinets
Boards
AMIX x/x/x-1
The AMIX-1 (Analog Mixed Line) board is used to connect the analog public
network (PSTN) to the PBX. It has the following characteristics:
- 4 analog line accesses
- a maximum of 8 UA
interfaces - a maximum of 8 Z
interfaces
- an OBC system interface supporting AT, Z and UA
signaling - protection features
OUTPUT PORTS (FACEPLATE)
Types:
AMIX 4/4/4 -1
AMIX 4/8/4 -1
AMIX 4/4/8 -1
RJ 45 PIN SOCKET ASSIGNMENT
Connection Diagram:
SAME as other modules
LANX -1
Cabinets
Boards
The LAN X board (Ethernet LAN Switch) serves to connect Ethernet terminals (IEEE 802.3 compatible)
Connection Diagram
GENERAL REQUIREMENTS
+
PC
CONNECT
OMC Software
OXO System
OMC Passwords - Each Levels are protected w/ unique passwords. These password
can be change depending on your requirement. Below are the
default passwords:
- Operator Access = help1954 Administrator Access= kilo1987
Connect to PCX
Press OK
Step 2
kilo1987
Select ADMINISTRATOR
Enter correct password & Press
OK Step 4
Assuming that PMC is logged-in successfully, the administrator should see the ff menus:
Subscriber - Use the this menu for modifying pre-programmed profiles of All Extensions.
GROUP - For modifying Operator Groups, Hunting Groups & Pickup groups. System - Basic
modifications for System Date & Time, Numbering Plans, System software key Common SD for Add/delete & edit of Company Speed Dials/ Directory & Class grouping External Access Displays the current setting for External lines & edits of trunk groups.
Apply
Physical
Address
Of a Port
Extension
Number
Assigned to
A User
Phone set
Model assigned
to a user
Name of a user,
Used by Dial By Name
features
Detailed
Configuration
Of a user
Apply
Select, edit,
Add, Delete
Entries or members
Of an Operator group
There are 8 groups:
1 for Default Group
1 for Opening Hours
1 for Restricted Hours
Each group has 8
members
Select, edit,
Add, Delete
Entries or members
Of a User Group/s
There are 30 groups that
Can be created, from 540
Up to 570, each group has
16 members
Select, edit,
Add, Delete
Entries or members
Of a Paging Groups
There are 8 groups that
Can be created, each group has
32 members
Attendant GROUPS
Select, edit,
Add, Delete
Entries or members Of
an Operator group
There are 8 groups: 1
for Default Group 1 for
Opening Hours 1 for
Restricted Hours Each
group has 8 members
Apply
HUNTING GROUPS
Select, edit,
Add, Delete
Entries or members
Of a User Group/s
There are 30 groups that
Can be created, from 540
Up to 570, each group has
16 members
Apply
BROADCAST GROUPS
Select, edit,
Add, Delete
Entries or members Of a
Paging Groups There are
8 groups that
Can be created, each group has
32 members
Apply
PICKUP GROUPS
Apply
Numbering Plans
Select, edit,
Add, Delete
Entries or members Of
an Operator group
There are 8 groups: 1
for Default Group 1 for
Opening Hours 1 for
Restricted Hours Each
group has 8 members
Use this to
Select number
formats
Apply
Select to Navigate
On advanced
Numbering Plan
Configuration
Used by
Internal
Users of the
PCX System
Used by
External callers,
TELCO, Networks
To reach internal
Users via AA or DID
Same as Internal
Numbering Plan,
Used during
Restricted hours
Numbering Plans
For Private PABX
Networking
Numbering Plans
Intended for PBX
Features while in
conversation
Software KEYS
Actual CPU ID
Actual Software
Key Codes
Apply
On These Screen Menu , the SYSTEM will allow you to VIEW all the Active
Licenses of the Omni-PCX Office.
Each TABs are Comprise of licenses that applies to a group or specific features
& Application.
Values indicated on TABs are not to modify. These are dependent on SWK
Apply
Click here to go to
Advance configuration
Validate & Apply any
Modification for BASIC
MENU
Apply
CONNECT
DATA TRANSFER
PC w/
OMC
RESTORE
OXO System
Step 1
Step 2
Step 3
Step 4
End of Document