Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
BS 5649-2:
1978
EN 40-2
Incorporating
Amendment No. 1
Specification for
Lighting columns
Part 2: Dimensions and tolerances
UDC 624.971:628.971:621.753.1
BS 5649-2:1978
Cooperating organizations
The European Committee for Standardization, under whose supervision this
European Standard was prepared, comprises the national standards
organizations of the following Western European countries:
Austria
Belgium
Denmark
Finland
France
Germany
Ireland
Italy
Netherlands
Norway
Portugal
Spain
Sweden
Switzerland
United Kingdom
sterreichisches Normungsinstitut
Institut Belge de Normalisation
Dansk Standardiseringsraad
Suomen Standardisoimisliitto, r.y.
Association Franaise de Normalisation
Deutsches Institut fr Normung E.V.
Institute for Industrial Research and Standards
Ente Nazionale Italiano di Unificazione
Nederlands Normalisatie-instituut
Norges Standariseringsforbund
Repartio de Normalizao
Instituto Nacional de Racionalizacin y Normalizacin
Standardiseringskommissionen i Sverige
Association Suisse de Normalisation
British Standards Institution
Date of issue
Comments
3136
December
1979
BS 5649-2:1978
Contents
Cooperating organizations
National foreword
Brief history
Foreword
1
Scope and field of application
2
Post top columns, main dimensions
3
Columns with brackets, main dimensions
4
Door openings and cable entry slots
5
Column foundation, planting depth and base plate
6
Flange plate
7
Connection dimensions for lanterns
8
Tolerances
Annex
National particularities
National appendix A
National appendix B
National appendix C
Figure 1
Figure 2
Figure 3 Position of door and cable entry slot
Figure 4 Dimensions of cutout
Figure 5a
Figure 5b
Figure 6
Figure 7
Figure 8
Figure 9a
Figure 9b
Figure 10a
Figure 10b
Figure 11
Table 1 Factor G
BSI 09-1999
Page
Inside front cover
ii
2
2
3
4
5
6
7
8
9
10
11
11
11
11
12
4
5
6
6
7
7
8
8
8
9
9
9
9
10
11
BS 5649-2:1978
National foreword
This BS/EN is being produced in the following Parts:
Part 1: Definitions and terms;
Part 2: Dimensions and tolerances;
Part 3: Materials1);
Part 4: Surface protection of metal columns1);
Part 5: Base compartment and cableways1);
Part 6: Loads1);
Part 7: Verification of structural design by calculations1);
Part 8: Verification of structural design by testing1);
Part 9: Special requirements for concrete columns1).
A further Part dealing with special requirements for plastics columns is in an
early stage of preparation.
BS 5649 will be issued in Parts as they are completed and approved, and until the
whole document is published it will not be possible to supersede the present
British Standards for lighting columns. As the Parts are issued recommendations
will be given for their implementation together with a list of clauses in the
existing standards which they will eventually supersede. It is hoped that a
gradual change-over will be obtained which will terminate with the total
withdrawal of the existing standards.
The British Standards affected are:
BS 1308:1970, Specification for concrete street lighting columns.
BS 1840:1960, Specification for steel columns for street lighting.
BS 3989:1966, Specification for aluminium street lighting columns.
It is anticipated that the affected clauses in the existing standards will be
withdrawn in accordance with the following timetable:
BS 1840 and BS 3989, One year from the publication of this Part of this standard.
BS 1308, Three years from the publication of Parts 6, 7, 8 and 9 of this standard.
In the interim period it is permissible for dimensions and tolerances for lighting
columns to be based on either the existing standards or on BS 5649-2. Purchasers
specifying lighting schemes during the interim period should, where possible,
permit either alternative.
BS 5649-2 covers some or all of the requirements also covered in the following
clauses of the existing British Standards:
BS 1308
1.1
Scope
1.8.2 Straightness tolerances
1.8.3 Column height and bracket projection
1.10 Bracket projection
1.11 Lantern fixing
1.12.1 Door and door opening
1.18 Service connections
1) In
ii
course of preparation
BSI 09-1999
BS 5649-2:1978
BS 1840
1 Scope
5 Tolerances
6 Doors and door openings
8 Base-plates
10 Service slots
11 Relative positions of door openings, service slots and bracket arms
12 Recommended depth of columns in the ground
13 Lantern fixing
BS 3989
1 Scope
6 Tolerances
8a) Doors and door openings
9 Base-plate
11 Service slot
12 Relative positions of bracket arm, door opening and service slot
13 Recommended depths of columns in the ground
14 Lantern fixing
This standard includes columns of height greater than those that were envisaged
in the scope of the existing BS 1308, BS 1840 and BS 3989. It is therefore
inappropriate to use the design loading requirements in these British Standards
for columns over 15 m in nominal height; for such columns the loading
requirements should be agreed between the purchaser and the supplier, pending
the issue of other Parts of this standard.
Advice regarding the choice of planting depth is given in National appendix B.
Convention. In this European Standard the comma has been used as a decimal
marker. In British Standards it is current practice to use a full point on the
baseline as the decimal marker.
A British Standard does not purport to include all the necessary provisions of a
contract. Users of British Standards are responsible for their correct application.
Compliance with a British Standard does not of itself confer immunity
from legal obligations.
Summary of pages
This document comprises a front cover, an inside front cover, pages i to iv,
the EN title page, pages 2 to 12 and a back cover.
This standard has been updated (see copyright date) and may have had
amendments incorporated. This will be indicated in the amendment table on the
inside front cover.
BSI 09-1999
iii
iv
blank
EUROPEAN STANDARD
EN 40-2
NORME EUROPENNE
Edition 1
June 1976
EUROPISCHE NORM
UDC 624.971:628.971:621.753.1
Key words: Luminaire, lighting column, dimension, dimensional tolerance
English version
Lighting columns
Part 2: Dimensions and tolerances
Candlabres
Dimensions et tolrances
Lichtmaste
Masse und zulssige Abweichungen
CEN
European Committee for Standardization
Comit Europen de Normalisation
Europisches Komitee fr Normung
Central Secretariat: rue de Stassart 36, B-1050 Brussels
Copyright reserved to all CEN members
EN 40-2
Brief history
This European Standard, drawn up by technical
committee CEN/TC 50 Lighting poles and spigots
(secretariat DIN), was submitted to the ballot of
CEN members in February 1976 with a view to its
adoption as a European Standard.
It was adopted as such by CEN on 30 June 1976 on
the strength of its acceptance by the following
member countries:
Austria, France, Germany, Ireland, Italy,
Netherlands, Portugal, Switzerland,
United Kingdom.
Foreword
In producing this Part of this standard it was
recognized that columns with nominal heights
and/or bracket projections not specified in this
standard will still be needed to replace columns in
existing lighting schemes. However, all columns for
new lighting schemes should be selected from the
nominal heights and bracket projections specified in
this document.
BSI 09-1999
EN 40-2
BSI 09-1999
EN 40-2
Figure 1
BSI 09-1999
EN 40-2
Figure 2
BSI 09-1999
EN 40-2
2)
3)
It is recommended that this dimension be approximately 600, but in no case shall it be less than 300; no maximum is specified.
4)
It is recommended that the door opening is positioned parallel to the bracket on the side away from the direction of traffic.
Figure 3 shows the position for right hand drive roads.
BSI 09-1999
EN 40-2
Figure 5a
Figure 5b
1)
The planting depth, e, shall be selected from the values given in the table taking into consideration the calculations made
beforehand and the ground conditions.
BSI 09-1999
EN 40-2
Figure 6
Figure 7
h
m
u5
u 12
u 20
260
400
400
500
d 1a
M18
M24
M27
a
Figure 8
sa
8
10
200
300
300
400
20
d2
22
30
33
min.
d1
M18
M24
M27
la
min.
400
500
700
EN 40-2
d 1b
60
76
102
Figure 9a
Post top lanterns
l1
70
130
250
Figure 9b a
d 2b
42
60
l2
100
100
250
Figure 10a
Figure 10b
2)
See clause 1.
BSI 09-1999
EN 40-2
2%
8.5 Fixing angle
The tolerance for the fixing angle of the lantern
fixing axis, from the horizontal, shall be 2 when
not under load; the deviation between the bracket
axis and lantern fixing axis shall also not
exceed 2.
8.6 Door opening and cable entry slot
For the opening dimensions:
+ 5 mm
0 mm
Figure 11
8 Tolerances
8.1 Straightness
x u 0,003 l; l = h + e
%x u 0,003 %l; %l W 1 m
See Figure 11.
Measurement shall be carried out in unloaded state
(column lying horizontally).
8.2 Total length of post top columns
8.2.1 Longitudinally welded columns
With planted section:
With flange plate:
0,5 %
or 25 mm
0,6 %
0,5 %
0,6 %
or
50 mm
10
1%
1,2 %
BSI 09-1999
EN 40-2
Annex
National particularities
In France it is admissible to use in addition to the
bracket projections fixed in clause 3 also the bracket
projections w = 1 m and w = 1,5 m.
National appendix A
The United Kingdom participation in the
preparation of this European Standard came under
the direction of the Road Engineering Standards
Committee of BSI. The following organizations were
involved in the work on this standard:
Aluminium Federation
Association of Public Lighting Engineers
British Plastics Federation
British Precast Concrete Federation Ltd.
British Steel Industry
Cement and Concrete Association
County Surveyors Society
Department of Transport
Design Council
Electricity Supply Industry in England and Wales
Institution of Highway Engineers
Institution of Mechanical Engineers
Institution of Municipal Engineers
Lighting Column Manufacturers Association
Lighting Industry Federation Ltd.
BSI 09-1999
Soil type
630
390
230
11
EN 40-2
12
BSI 09-1999
blank
BSI
389 Chiswick High Road
London