Specifications

PANEL METER

MT4W SERIES
A

Thank you very much for selecting Autonics products.


For your safety, please read the following before using.

Caution for your safety


Please keep these instructions and review them before using this unit.
Please observe the cautions that follow;
Warning Serious injury may result if instructions are not followed.
Caution Product may be damaged, or injury may result if instructions are not followed.
The following is an explanation of the symbols used in the operation manual.
caution:Injury or danger may occur under special conditions.

Warning
1. In case of using this unit with machinery(Ex: nuclear power control, medical equpment, ship, vehicle, train,
airplane, combustion apparatus, safety device, crime/disaster prevention equipment, etc) which may cause
damages to human life or property, it is required to install fail-safe device.
It may cause a fire, human injury or damage to property.
2. It must be mounted on the Panel.
It may cause electric shock.
3. Do not connect terminals when it is power on.
It may cause electric shock.
4. Do not disassemble and modify this unit. Please contact us if it is required.
It may cause electric shock or a fire.
5. Please check the number of terminal when connect power line or measured input.
It may cause a fire.

Caution
1. This unit shall not be used outdoors.
It might shorten the life cycle of the product or cause electric shock.
Use this product indoors only. Do not use the product outdoors or at locations subject to the temperatures or
humidity outside. (Example : rain, dirty, frost, sunlight, condensation, etc.)
2. When connecting wire, AWG 20(0.50mm) should be used and screw bolt on terminal block with 0.74Nm to
0.90Nm strength.
It may cause malfunction or a fire due to contact failure.
3. Please observe the rated specification.
It might shorten the life cycle of the product and cause a fire.
4. Do not use the load beyond the rated switching capacity of Relay contact.
It may cause insulation failure, contact melt, contact failure, relay broken, fire etc.
5. In cleaning the unit, do not use water or organic solvent. And use dry cloth.
It might cause an electric shock or fire that will result in damage to the product.
6. Do not use this unit at place where there are flammable or explosive gas, humidity, direct ray the sun,
radiant heat, vibration, impact etc.
It may cause explosion.
7. Do not inflow dust or wire dregs into inside of this unit.
It may cause a fire or mechanical trouble.
8. Please connect properly after checking the polarity of measurement terminals.
It may cause a fire or explosion.

Front panel identificationsafety

45
Min. 52.0

92

(Unit:mm)

<Option>

MT4W-DV-

Relay output+Current output[MT4W-

250mV/50mV

5V/1V
50V/10V
500V/100V
COM

HOLD/
ZERO

MT4W-DA2

5mA/2mA
50mA/4-20mA

500mA/200mA
5A/2A
COM

HOLD/
ZERO

2V/1V

20V/10V
110V/50V
500V/250V
COM

MT4W-AA1

100mA/50mA
500mA/250mA

1A
5A/2.5A

MAIN OUT
CONTACT OUT:250VAC 3A 1a
RESISTIVE LOAD

+ SOURCE
12-24VDC 5W
100-240VAC
50/60Hz 5VA

MT4W-AV1

HOLD/
ZERO

COM

4
6 8
+24VDC
GO 30mA Max.
COM1 HI LO
1

4
6 8
+24VDC
30mA Max.

COM1 HI LO
1

11 13 15 17 19

6 8 10 12 14 16 18 20
+24VDC
GO
30mA Max.
DC4-20mA
Load 600 Max.
COM1 HI LO
0V
1

13

14

15
LO

- 4]

Main Out
(NPN Open
Collector)
12-24VDC
Max. 50mA

6 8 10 12 14 16 18 20
POL CLOCK LATCH
+24VDC
30mA Max.
SERIAL OUT
(NPN OPEN COLLECTOR)
12-24VDC Max. 50mA

0V
7

COM2 DATA
11 13 15 17 19

COM1 HI LO
1 3
5

- 8]

0V
7

PNP open collector output+BCD output[MT4W2

6 8 10 12 14 16 18 20
+24VDC
B D D1 D3 DOT COM2
30mA Max.
BCD OUT
(NPN OPEN COLLECTOR)
12-24VDC Max. 50mA
COM1 HI LO
0V A C D0 D2
POL
1 3
5 7
9 11 13 15 17 19

PNP open collector output+RS485 output[MT4W2


GO

Main Out
(PNP Open
Collector)
12-24VDC
Max. 50mA

- 9]

6 8 10 12 14 16 18 20
+24VDC B(-) SG
30mA Max.
RS485

COM1 HI LO
3

Main Out
(PNP Open
Collector)
12-24VDC
Max. 50mA

0V A(+) SG
5

11 13 15 17 19

Time chart of serial output and BCD output


BCD output(Negative logic)
ta tw

Digit signal
Output data

tb

31.2ms

Digit
signal

D3
D2
D1
D0
A
B

Data
signal

C
D
dot

Display

*tw
Latch

*ta

Clock

Cn-1

Data

Cn

C1

Dn-1

Dn

D1`

Data 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Output DP D C B A DP D C B A DP D C B A DP D C B A
Clock
L

H
H

H
H

H
L

H
H

Data H H L H H H H H L L L H H L H H H H H L

H
tw
*ta

tb

Latch
H
H

Display

*When clock pulse change High to Low, Data will be output.

This function is to display setting(-1999 to 9999) of particular High/Low-limit value in order to display High/Low-limit
value of measured input.
If measured inputs are 'a' or 'b' and particular values are 'A' or 'B', it will display a=A, b=B as below graph.

Display
value B

Display
value B

A
a

b
Input value

b
Input value

Display
value B

b
Input value

Display
value

A
a

b
Input value

A
B

Input value

Display
value A
B

b
Input value

Error display is released


automatically when it is in the
Flashes when measurement input is exceeded the max.allowable input (110%)
measured and display range.
Flashes when measuremnet input is exceeded the min.allowable input (-10%) 'LLLL' is displayed when the
measured input is 4-20mA.
Flashes when display input is exceeded H-SC set value
After flashing 'OVER' 2 times
Flashes when display input is exceeded L-SC set value
when it exceeds the zero range,
Flashes when input frequency is exceeded the max. display value of measured range
it returns to RUN mode.
Flashes when it exceeds zero range (99)

Display Description
HHHH
D-HH
D-LL
F-HH
OVER

Display range
-1999 to 9999
-199.9 to 999.9
-19.99 to 99.99
-1.999 to 9.999

DOT
0
)0
)00
)000

(Display range is variable according


to decimal point position.)
Please wire the proper
terminal it its max. input
within 30 to 100% of the
input terminal. When it is
higher than input, it may
cause terminal breakdown
and over display range.The
accuracy is decreased when
it is connected to the terminal
under 30%.
In case of 0 to 110V (110P)
of AC voltage range and using
P.T(potential transformer)
for 440V/110VAC, if 110V is
input, and the unit displays
440V automatically by preset
scale value for P.T user's
convenient.

Initialization function

The above specifications are subject to change and some models may be discontinued without notice.

PA 1
(Parameter 1)

RUN

Press

Current output(DC4-20mA)
Scale adjustment function
[PA 2 : FS-H/ FS-L]

It set current output for the display value at the current


output DC4-20mA. It sets display value for 4mA at FS-L
and 20mA at FS-H and the range between FS-H and
FS-L should be 10% F.S. (When it sets as under 10% F.S.
automatically.) Preset display value is fixed to output as
4mA at under FS-L and 20mA at over FS-H.
Output
20mA
Min. setting range
F.S.10%
FS-L

Diplay value

FS-H

Error correction function

INIT

NO

Input bias

INbE exponent
OUtT Out type

HYS Hysteresis

Startup compen

STaT -sation time

PA 2
(Parameter 2)

LhST

HI
GO
LO

MT4W-DA/AA

AC frequency measurement
function [PA1 : DISP]

It measures input signal frequency when it is AC input.


It uses fixed decimal point[PA1:DOT], measured range
can be changed by setting and measured range of
decimal point position is as below chart.
It is available to adjust the upper gradient at [PA1:INbH]
and [PA1:INbE]. In order to measure frequency
normally, input signal, over 10% F.S. of measured range
should be supplied. Please select the proper point of
measurement terminal.
Measured range
Decimal point
0.000
0.00
0.0
0
position
Measurement 0.100 to 0.10 to 0.1 to
1 to
range
9.999Hz 99.99Hz 999.9Hz 9999Hz
Accuracy of frequency measurement: Below 1kHz, F.S.
0.1rdg 2digit. From 1kHz to 10kHz, F.S 0.3rdg 2digit.
INB.H : 00.100 to 9.999[Gradient adjustment of high value]
1
INB.E : 10-2, 10-1, 10-0, 10 [Index adjustment of INB.H]

Zero adjustment function

(Picture 1)

Y
time

time

Y
0

15.000
12.000
9.000
6.000

(Example of gradient
correction)
Indication
value for
measured
input Input
value

3.000
1.000
X
Input value

Setting method

H-SC
Unavailable
7.500
5.000
3.750
3.000

0.2 0.4 0.6 0.8 1V


L-SC
0.000
0.000
0.000
0.000
0.000

INbH
1.000
2.000
3.000
4.000
5.000

Note
In this case, any
setting methods
display the same
display value.

HhST

HI
GO
LO

LlST

HI
GO
LO

LdST

GO
LO

If it is equal or lower than Low setting value, LO output is ON.


If it is higher than Low setting value, GO output is ON.
If it is equal or higher than High setting value, HI output is ON.
If it is equal or lower than High setting value, GO output is ON.
LO output is ON when it is equal or lower than Low setting value.
HI output is ON when it is equal or higher than High setting value.
GO output is ON when it is higher than Low setting value, and lower
than High setting value.

H
H
H
H
H

Set startup compensation time. Setting range: 00 to 99.9sec.


Set monitoring delay time
for peak value(sec)

DIsT Display time

Set sampling time(sec.)

ZERO Zero Key

Set usage of front side zero


adjustment key

EVIN Event Input

Set external terminal(6, 7)


function

Setting range: 00 to 30sec.


Setting range: 0.1 to 5.0 sec.
(Variable by 0.1sec.)
NO: Not use front side zero adjustment key
YES: Use front side zero adjustment key
HOLD: Use external terminal as Hold terminal
ZERO: Use external terminal as zero point
adjustment terminal

Set the upper value output


FS-H Full scale High point or PV output

PA 0
(Parameter 0)

Min. set range: Min. 10% F.S.

Set the lower value output


FS-L Full scale Low point or PV output
Set communication address
ADRS Address
BPS Bit per second Set baudrate(bps)
Set lock function
LOC Lock
Set High setting value
hSET High set
Set Low setting value
lSET Low set
Max. value by data monitoring
hPEK High peak
Min. value by data monitoring
lPEK Low peak

Parameter setting

Max. set range: Max. FS-H 10%


Setting range: 01 to 99
Setting range: 1200, 2400, 4800, 9600
Setting range: OFF, LOC1, LOC2, LOC3
Setting range can be set within the display
range of STND/ SCAL
Initializes the monitored data value by
pressing any one of
keys.

Parameter 0

key in RUN mode and it


Press
enters PA-0 group.
key for over 3 sec. in
Press
key 3 sec.
RUN mode, it displays [PA1].
PA0
PA1
Press
key for over 5 sec. in RUN
key
mode, it displays [PA2] after [PA1].
key 2 sec.
When pressing
key continually,
PA2
key 3 sec.
it stops displaying at [PA2].
It is advanced to current display parameter releasing
key at [PA1] or [PA2].
key for over 3 sec. in any parameter groups, it
Press
returns to RUN mode.
If any key is not entered for 60 sec. in each parameter, it
returns to RUN mode.
key within 2
After returning to RUN mode, press
sec., it returns to previous parameter. (Refer to the below
descriptions of each parameter group.)
PA-0 group cannot be entered when preset output mode of
[PA2] group is OFF.
RUN

key 3 sec.

key

If PEK.T of Parameter2 is set as '00 S',


hPEK and lPEK are not displayed.

RUN

key touch

Set preset High-limit value. (It is not displayed


when OUtT mode value of PA2 is OFF)
Change the value with
keys.

hSET

Set preset Low-limit value. (It is not displayed


when OUtT mode value of PA2 is OFF)
Change the value with
keys.
It displays High-limit monitoring value
(High peak) in RUN mode.
It is initialized by pressing any one of
keys.

lSET
hPEK

It displays High-limit monitoring value


(Low peak) in RUN mode.
It is initialized by pressing any one of
keys.

lPEK

Parameter 1
RUN

Item
key for 3 sec.

Range of measured input

MT4W-DV 500V

PA1

MT4W-DA 5A

100V
2A

MT4W-AV 500V

50V

)5A

10V

)2A
110P()

250V

5V

50MA

1V

)25V

4-20

50MV

5MA

50V

20V

10V

)25A

)1A

50MA

2MA

2V

1V

500V
5A
500V

IN-R

Select measured input specification.


(Refer to Specification of
measured input and range.)

DISP

Select the display method of measuring input.


Setting range: STND, SCAL, FREQ.
- Refer to measuring input specification and range chart. (FREQ mode is only for AC measuring type.)

IN-T

Select measurement method when it is AC input.


Setting range: AUG, RMS(Average: AVG/Root mean square: RMS)

When DISP is STND

STND

It shows max.display
value of standard
specification.
Display value is fixed.

MT4W-AA 5A

@5A

1A

)5A

When DISP is SCAL

When DISP is FREQ

Set decimal point position.

Set frequency measured range


AC frequency
measurement function part.)

DOT Setting range:


H-SC

5A

110P is standard specification of 440/110P.T.

DOT (Refer to

0, )0, )00, )000


Set display value for max.
input of measured input

Setting range: )100 to %000


Adjust Low-limit display

500V

No output

Setting range: OFF, lST, hST, LhST,


HhST, LlST, LdST
Setting range: 1 to 10% F.S.

PEkT Peak time

Flash twice
in order and
it returns to
5A RUN mode.

MT4W-DV/AV

HI
GO

Setting range: 10-2, 10-1, 100, 101

Adjust High-limit display

H: Hysterisis

hST

Setting range: -99 to +99

Set display index of


frequency mode
Set operation mode of
preset output
Set hysteresis value

INbH value gradient for max. input.

Operation

It is dispayed at SCAL /FREQ only and set


the decimal point position
STND/ SCAL: Correction range 0.100 to 5.000
FREQ: Correction range 0.100 to 9.999

Set decimal point position

Correct Low-limit value


INbL Input bias low of display value

YES

Preset output mode[PA 2 : OUtT]

GO
LO

These are displayed at SCAL


It sets max. display value/min. display
value(-1999 to 9999)

Set display value for min.

Error correction function],


Refer to description [
[ Error display function] and [ Parameter 2] for
function and error.

lST

Note
Available AC type only.
Setting range: STND, SCAL, FREQ
Display Max. display value of STND
Available AC type only.

L-SC input of measured inputc

The offset correction range of INbLis within -99 to for D-0,


D-1 digit regardless of dicimal point.

OFF

DOT Dot

Function
Selectable RMS/AVG in AC type
Selection of input range
Selection of display type
Standard scale range
Frequency display
Scale range
Set max. value of display range
Set min. value of display range

YES

It adjusts the indication value of the optioanl configured


input value as zero by force, zero point error can be
adjusted with 3 ways as below.
When zero point adjustment with front key and
Hold terminal is finished normally, zero point
of measurement terminal is displayed and the
adjusted value is saved at INbL automatically.
Input correc
Input external
Operation
Front side key
-tion value
signal
Short-circuit
PA1 : Direct Press
input correc
Hold terminal
key for 3sec. of external
Description -tion value
at
the
at
method at
No. 6, 7 over
RUN mode. min. 50m.
INbL

Output operation

Input type
Input range
Display
Standard
Frequency
Scale
High scale
Low scale

for over 5 sec.

It corrects display value error of measured input.


INB.L: 99(Adjust deviation of low value)
INB.H: 5.000 to 0.100(Correct gradient(%) of high value)
Diplay value=(Measured value INB.H) + INB.L
When the measured range is 0 to 500V, and the display
range is 0 to 500.0. If the low display value is "1.2" to
0V input, set -12 as the INbL value to display "0.0" by
adjusting the offset of the low value.
The display value to the 500V measured input varies by
adjusting the offset of the low value. If this display value is
"501.0", calculate 500.0/501.0(the desired display value/
the display value), and set the 0.998 correction value as the
INbH to display "500.0" by adjusting the gradient of the high
value.

Mode

IN-T
IN-R
DISP
STND
FREQ
SCAL
H-SC
L-SC

Correct High-limit value


INbH Input bias high of display value

This function is to initialize parameter as factory difault.

It monitors Max./Min. display value based on the current


displays value and then displays the data at hPEK, lPEK
of parameter 0. Set the delay time(0 to 30 sec.) at PEkT of
parameter 2 in order to prevent malfunction caused by initial
over current or over voltage, when monitoring the peak value.
Delay time is 0 to 30 sec. and it starts to monitor the peak
value after the set time. When pressing any one of
key at hPEK, lPEK of parameter 0, the monitored data is
initialized.
Monitoring function is not displayed when the delay time is
set as "00 S" at PEkT of parameter 2.

Error display function


LLLL

0.0 to 500.0
0.0 to 100.0
0 to 50.00
0.00 to 10.00
0.00 to 5.000
0.000 to 1.000
0.00 to 250.00
0.00 to 50.00
0.000 to 5.000
0.000 to 2.000
0.0 to 500.0
0.00 to 200.0
0.00 to 50.00
00.00 to 20.00
0.000 to 5.000
0.000 to 2.000
0.0 to 500.0
0.0 to 250.0
0.0 to 440.0
0.00 to 50.00
0.00 to 20.00
0.00 to 10.00
0.000 to 2.000
0.000 to 1.000
0.000 to 5.000
0.000 to 2.500
0.000 to 1.000
0.0 to 500.0
0.00 to 250.0
0.00 to 100.0
0.00 to 50.0

Display cycle delay function [PA 2 : DIsT]

hSET
lSET

Prescale function[PA1 : H-SC/L-SC]


Display
value B

4.33315M
4.33315M
433.15k
433.15k
43.15k
43.15k
2.15k
2.15k
0.01
0.01
0.1
0.1
1.0
1.0
10.0
10.0
4.987M
4.987M
1.087M
1.087M
200k
200k
20k
20k
0.01
0.01
0.05
0.1
0.1
0.5
0.5

It corrects the gradient of prescale value and display value.


(Picture 1) Display value Y can be used as , times
against X input value by correction function[ INbH] and
used as correction function of max. display value( H-SC).
Adjustment range is 0.100 to 5.000 and multiply current
gradient.
Ex)Input:200mVDC, Display:3.000 for MT4W-DV type
Select 0-1VDC(1V) for measured input in Parameter 1.
S tandard specification in input: 0-1VDC and
1.000 therefore it has to be 15.000( H-SC)
for 1VDC(Input) in order to display 3.000 for
DC200mV(Input).
But it is unable due to setting range is 9.999
In this case, please check below chart.
Please set as INbH H-SC = 15.000

t : 20ms
ta : 0.05ms
tw : 5ms
tb : 4.95ms

*tb

Parameter

Parameter Display

Prescale Display range [SCAL]

Gradient correction function[PA 1 : INbH] Diplay value

Serial output(Negative logic)


t : 7.8ms
ta : 0.5ms
tw : 5ms
tb : 2.3ms

Data
t

Display range [STND]

[PA 1 : INbH/ INbL]

- 3]

GO

- 5]

- 7]

Main Out
(PNP Open
Collector)
12-24VDC
Max. 50mA

COM2 DATA
11 13 15 17 19

AC
current

4mA

6 8 10 12 14 16 18 20
POL CLOCK LATCH
+24VDC
30mA Max.
SERIAL OUT
(NPN OPEN COLLECTOR)
12-24VDC Max. 50mA

GO

- 6]

Main Out
(NPN Open
Collector)
12-24VDC
Max. 50mA

PNP open collector output+Low speed serial output[MT4W-

Main Out
(PNP Open
Collector)
12-24VDC
Max. 50mA

11 13 15 17 19

12

GO

COM1 HI LO

Main Out
(NPN Open
Collector)
12-24VDC
Max. 50mA

PNP Open Collector output+Current output[MT4W2

mA

- 1]

11

GO

Main Out
(NPN Open
Collector)
12-24VDC
Max. 50mA

RS485
9

COM

NPN Open collector output+Low speed serial output[MT4W-

- 2]

AC
voltage

Input impedance

Monitoring Max./Min. display


value function
[PA 0: hPEK/lPEK,PA 2: PEkT]

15

8 10 12 14 16 18 20
+24VDC
30mA Max.
DC4-20mA
Load 600 Max.
COM1 HI LO
0V
1 3
5 7
9 11 13 15 17 19

11 13 15 17 19

10 12 14 16 18 20
B(-) SG

LO

+ SOURCE
12-24VDC 5W
100-240VAC
50/60Hz 5VA

0V A(+) SG
5

GO

14

GO

NPN Open Collector output+RS485 output[MT4W-

GO

HI

- 0]

DC4-20mA
Load 600 Max.

NPN open collector output+Current output[MT4W-

10 12 14 16 18 20
B D D1 D3 DOT COM2
BCD OUT
(NPN OPEN COLLECTOR)
12-24VDC Max. 50mA
A C D0 D2
POL

0V
5

13

HI

NPN Open Collector output+BCD output[MT4W2

12

10

+ HOLD/
SOURCE
ZERO
12-24VDC 5W
100-240VAC
50/60Hz 5VA

11

DC
current

Measured input
and range
0-500V [500V]
0-100V [100V]
0-50V [50V]
0-10V [10V]
0-5V [5V]
0-1V [1V]
0-250mV [)25V]
0-50mV [50Mv]
0-5A [5A]
0-2A [2A]
0-500mA [)5A]
0-200mA [)2A]
0-50mA [50MA]
4-20mA [4-20]
0-5mA [5MA]
0-2mA [2MA]
0-500V [500V]
0-250V [250V]
0-110V [110P]
0-50V [50V]
0-20V [20V]
0-10V [10V]
0-2V [2V]
0-1V [1V]
0-5A [5A]
0-2.5A [@5A]
0-1A [1A]
0-500mA [)5A]
0-250mA [)25A]
0-100mA [)1A]
0-50mA [50MA]

In some applications the measured input may fluctuate which in turn causes the display to fluctuate. By adjusting the
display cycle delay function time at DIS.T of parameter 2, the operator can adjust the display time within a range of 0.1
sec to 5 sec. For example, if the operator sets the display cycle time to 4.0 sec., the display value displayed will be
the average input value over 4 sec. and also will show any changes if any every 4 sec.

MAIN OUTCONTACT OUT:250VAC


3A 1aRESISTIVE LOAD

+ -

10

Relay output[MT4W-

SOURCE
12-24VDC 5W
100-240VAC
50/60Hz 5VA

DC
voltage

+0.8
-0

There are no 1, 2, 3 output indication in Indication type.

Terminal connection

Type

Min. 116
+0.6
-0

Startup compensation timer function[PA 2 : STaT]

This time function limits the operation of an output until the measured input(overvoltage or inrush current) is stable at
moment of power on. All outputs are off during startup compensation time setting after power is supplied.
Setting range: 00.0 to 99.9 (Unit: sec.), Factory default: 00.0

Specification of measured input and range [PA 1: IN-R]

Panel cut-out

1. HI: High output indication of preset


2 GO: GO output indication of preset
6
3 LO: Low output indication of preset
4.
: MODE Key
5.
: Control key
6. Unit label part

1
2
3

MT4W-4
MT4W-1
100-240VAC 50/60Hz
12-24VDC
90 to 110%
5VA
5W
7Segment LED display (red) (Character height: 14.2mm)
235 - DC Type: F.S.0.1% rdg2digit / AC Type: F.S.0.3% rdg3digit
Display accuracy
DC/AC Type: F.S.+0.3% rdg +3digit max. only for 5A terminal
-10 to 50 - DC/AC Type: F.S.0.5% rdg3digit
Input
DC Voltage/Current, AC Voltage/Current, AC Frequency
Max. allowable input 110% for each measured input range
A/D conversion method Practical over sampling using successive approximation ADC.
Sampling cycle
DC type: 50ms, AC type: 16.6ms
Max. indication range -1999 to 9999(4digit)
Relay output - Contact capacity: 250VAC 3A, 30VDC 3A/Contact composition: N.O(1a)
Preset output
NPN/PNP Open Collector output - 12-24VDC 2V 50mA Max.(Load resistance)
RS485 communication output - Baud rate:1200/2400/4800/9600, Communication method : 2-wire half duplex,
Sub output
Synchronous method: Asynchronous method , Protocol : Modbus type
(Transmission output) Serial/BCD output - NPN Open collector output, 12-24VDC Max. 50mA(Resistive load)
DC4-20mA output - Resolution: 12,000 division(Load resistance max. 600), Response time:Max. 450ms
Insulation resistance
Min. 100M (at 500VDC megger) between external terminal and case
Dielectric stength
2,000VAC for 1minute between external terminal and case
Noise stength
2kV the square wave noise (pulse width: 1) by the noise simulator
Mechanical
0.75mm amplitude at frequency of 10 to 55Hz (for 1 min.) in each X, Y, Z direction for 2 hours
Vibration
Malfunction
0.5mm amplitude at frequency of 10 to 55Hz (for 1 min.) in each X, Y, Z direction for 10 min.
Mechanical
100m/s (approx. 10G) in each X, Y, Z direction for 3 times
Shock
Malfunction
300m/s (approx. 30G) in each X, Y, Z direction for 3 times
Mechanical
Min. 20,000,000 operations
Relay
life cycle Malfunction
Min. 100,000 operations (250VAC 3A Load current)
Ambient
-10 to 50, Storage: -20 to 60
Environ temperature
-ment
Ambient
35 to 85%RH, Storage: 35 to 85%RH
humidity
Double insulation or reinforced insulation
Insulation type
(Mark: , dielectric strength between the measuring input part and the power part: 1kV)
Approval
1
Weight
Approx. 326g(Approx. 211g )
1: The weight with packaging and the weight in parentheses is only unit weight.
Environment resistance is rated at no freezing or condensation.

Diplay value

Model
Power supply
Allowable voltage range
Power consumption
Display method

LO output is ON when it is equal or higher than Low setting value.


HI output is ON when it is equal or higher than High setting value.
GO output is ON when it is lower than Low/High setting value.
LO output is ON when it is lower than Low setting value.
HI output is ON when it is equal or lower than High setting value.
GO output is ON when it is higher than Low/High setting value.
It is operated same with L.ST but LO output does not operated under
initial Low setting value, and it is ON from under next Low setting value.
If this is higher than Low setting value, GO output is ON.

hSETis displayed according to the setting of output operation mode, when user sets "OFF", hSET/lSETare not displayed.

INbL value deviation fot min. input.


Setting range: -99 to 99

Parameter 2
RUN

key 5 sec.

Select Preset output mode.

OUtT Setting range: OFF, lST, hST, LhST, HhST, LlST, LdST
Preset output mode"

preset hysteresis. within 10% of F.S.


HYS Set
But, it is not displayed when OUtT mode is OFF.

Set a display cycle.


Setting range: 0.1 to 5.0sec.
Enable zero point adjustment by front key operation to
select YES.
+
keys at the same time for 3sec.
The devication value is saved at INbL automatically.
Select either Hold input by No.6, 7 terminal or zero point
setting by external signal.
HOLD: Display value holding, ZERO: Zero point
adjustment by hold terminal.
Set high-limit value for DC 20mA output position of PV putput.
When changing input range and prescale mode, the
setting values of FS-H, FS-L are changed automatically
as max. and min. value of input range.

FS-L Set low-limit value for 4mA output position of PV output.

Press one

Setting
The saved
value
setting value
flashes evey
0.5 sec.

250V

4. Change the setting value by


or
key when
setting value flashes.
Ex) Change AC type measured input from
250V to 125V.
Setting
Setting
value
value

IN-R

Press one

250V

125V

DISP
5. When confitming the setting value with
key, the changed setting value flashes twice
and enters into the next setting.
6. It returns RUN mode from parameter by
pressing
key for 3 sec.

Set address of RS485 communication output.

ADRS Setting range: 01 to 99

Select baud rate of RS485 communication output.

BPS Setting range: 9600, 4800, 2400, 1200


LOC

2. When pressing
key in each parameter,
the initial mode of the parameter is displayed.
(Refer to the description of each parameter.)

IN-R

ZEKY Press both

FS-H

1. Advance to the parameter to be changed when


pressing
key continuously in RUN mode
and releasing
key at the parameter.
(Refer to " Parameter setting")

Ex)

Set monitoring delay time.

PEkT Setting range: 00 to 30sec.

EVIN

Set index for frequency display

3. When pressing one of , , keys in display


mode, the saved setting value is displayed.

startup compensation time.


STaT Set
Setting range: 00 to 99.9sec.

DIsT

Setting range: )100 to (999

INbE Setting range:10-2,


10-1, 10-0, 10 1

Change the parameter


setting value

PA 2

Refer to "

Adjust High-limit display

INbH value gradient for max. input.

Set key lock function and select from 4 kinds.


Setting range: OFF, LOC1, LOC2, LOC3
OFF No key lock function LOC2 Parameter 1, 2 lock
LOC1 Parameter 1 lock
LOC3 Parameter 0, 1, 2 lock

User manual for


communication
Visit our website (www.autonics.com) to
download the user manaul for communication of
MT series.

Caution for using

1. Allowable installation environment


If shall be used indoor
Pollution Degree 2
Altitude Max. 2000m
Installation Catergory.
2. Please use the terminal(M3.5, Max.7.2mm) when connectting the AC power supply.
3. Please use separated line from high voltage line or power line in order to avoid inductive noise.
4. Please install power switch or circuit breaker in order to cut off the power supply.
5. The switch or circuit breaker should be installed near by users for safety.
Max.
6. Be sure to avoid using this unit near by machinery making strong high frequency noise.
7.2mm
(High frequency welder & Sewing machine, High capacity SCR unit etc.)
7. When input applied, if "HHHH" or "LLLL" are displayed, it has some trouble with measuring input, please check the
line after power off.
Using line filter
Using Varistor
8. Noise inflowing from power line can cause serious
Install it closely from D.P.M.
problem for D.P.M.(Digital Panel Meter) driving by
HI
AC power supply. Even though there is condenser
110/
D.P.M. INPUT
for protecting noise between lines at primary side
110/
D.P.M. 220VAC
of power transformer, but it is very difficult to install
LOW
220VAC
protection components at small size product like
D.P.M. Therefore, please noise absorber circuit such
Earth ground
as line filter, varistor in external lines when voltage
failure occurs by power relay, magnet S/W and high
Using Double shield wire
Using Single shield wire
frequency equipment are operated in same line or
HI
HI
surge occurs by spark of high voltage or thunder etc.
9. Input line:Shield wire must be used when the
D.P.M.
D.P.M.
Vin
Vin
measured input line is getting longer in the place
LOW
LOW
occurring lots of noise.

It may cause malfunction if above instructions are not followed.

Major product
Photoelectric Sensors
Temperature Controllers
Fiber Optic Sensors
Temperature/Humidity Transducers
Door Sensors
SSR/Power Controllers
Door Side Sensors
Counters
Area Sensors
Timers
Proximity Sensors
Panel Meters
Pressure Sensors
Tachometer/Pulse (Rate) Meters
Rotary Encoders
Display Units
Connector/Sockets
Sensor Controllers
Switching Mode Power Supplies
Control Switches/Lamps/Buzzers
I/O Terminal Blocks & Cables
Stepper Motors/Drivers/Motion Controllers
Graphic/Logic Panels
Field Network Devices
Laser Marking System (Fiber, Co, Nd: Yag)
Laser Welding/Cutting System

http: //www.autonics.com
Trusted Partner In Industrial Automation
HEADQUARTERS:
18, Bansong-ro 513beon-gil, Haeundae-gu, Busan, South Korea,
48002
OVERSEAS SALES:
#402-404, Bucheon Techno Park, 655, Pyeongcheon-ro,
Wonmi-gu, Bucheon, Gyeonggi-do, South Korea, 14502
TEL: 82-32-610-2730 / FAX: 82-32-329-0728
E-mail: sales@autonics.com

EP-KE-77-0009L

Potrebbero piacerti anche