Sei sulla pagina 1di 8

TRIGENERATION SOLUTIONS

FOR AIRPORTS
POWERFUL.

2
CRUCIAL.

Airport safety relies on a dependable and steady power supply. Reliable


emergency power that is not dependent on the public grid, is a necessity.
Power production on site provides independence from unreliable
grids and reduces or eliminates the risk of blackouts and other supply
disturbances. With Wärtsilä gas power, an airport can guarantee that the
landing runway lighting is switched on within seconds of a public mains
system failure and that all airport services continue without hazard or
inconvenience to passengers or personnel.
But why settle for a costly emergency system, if you can turn a
necessity into profit? With a Wärtsilä power plant you can.
3D view of a typical CHP plant design with a
common engine hall and all needed ancilliary
spaces. Pre-engineered and pre-tested modules
minimize construction time on site and maximize
availability and reliability.

FLEXIBLE, ECONOMICAL AND RELIABLE single large unit, gas engines keep on running.
operation in accordance with varying load
With a Wärtsilä power plant you can power requirements. Single large units are not The robust design of the plant makes
up the entire airport. It is a proven, cost- achieving the same level of availability or adapt Wärtsilä gas power an excellent choice even in
effective alternative for a continuous supply of as flexibly to actual demand. earthquake-sensitive areas.
the electricity, heating and cooling needed at When service or repairs are due, the Because the gas pressure requirement in
airports all year round. work are carried out on-site in non-critical Wärtsilä gas engines is as low as 4.5 bar, no
A reciprocating engine is the most efficient hours, one unit at a time – without expensive high pressure gas supply is required and the
means today of converting liquid or gaseous transport to supplier’s factory or production engines will also cope with a gas supply that
fuels into energy. Wärtsilä power stations are downtime. suffers interruptions.
based on multi-unit installations of gas engines
or dual-fuel engines using light or heavy fuel TOUGH AND ROBUST LEAN, CLEAN AND QUIET
oils as back-up fuel. Compared to conventional solutions, a gas A Wärtsilä gas power plant situated in the midst
You can choose to build up the plant engine power plant is virtually immune to of the airport grounds is a considerate and
gradually and optimize the investment and the ageing. The engines will run with optimum responsible neighbour: clean, lean and quiet.
size of the plant during the years to come by performance from overhaul to overhaul. With Due to the unbeatable electrical efficiency
adding on more gensets according to demand. 64,000 actual running hours before the first throughout the load range, the CO2 emissions
Fast delivery and stepwise expansion enables major overhaul, Wärtsilä gas engines are are very low. Combined heat and power
rapid profit generation and involves smaller tougher than most. solutions minimize emissions and will easily
investment risks. Wärtsilä gas power offers unfaltering comply with the most stringent regulations.
Furthermore, a multi-unit installation performance even in challenging conditions. In cogeneration or trigeneration, no cooling
guarantees excellent operational reliability. While stifling heat, dryness and high altitudes of the engines is needed  as the heat from the
Gensets can easily be taken in and out of significantly weaken the performance of a process is taken into profitable use.

3
PERFECTLY COOL.

“Ladies and Gentlemen!  All passengers, Wärtsilä is becoming a major supplier of power DESIGN CONSIDERATIONS FOR
please be prepared to enjoy a reliable generation technology for airports, especially TRIGENERATION
power supply and pleasant thermal comfort in trigeneration applications – the continuous Flexibility in trigeneration can be improved by
during your stay here. Have a nice trip and supply of electricity, heating and cooling. using hot water and cold water storages, and
welcome again.” Trigeneration is cogeneration taken one also by using the topping-up control capacity
step further by including a absorbtion chiller. offered by compressor chillers or direct-fired
The inclusion of chillers starts to pay off auxiliary boilers. The running philosophy and
as soon as there are periods when not all control strategy are of importance and should
the heat can be used directly for heating be properly evaluated.
purposes or when there is a use for chilled The optimal solution is seldom based
water or air instead. Trigeneration is used for on a solution where the entire chilled water
air conditioning, for heating during winter and capacity is produced by absorption chillers.
cooling during summer. It can also be used The absorbtion chillers take the baseload and
for heating in one area and cooling in another are topped up with cheaper electrical driven
area. chillers. In this way the total investment cost
The concept is based on the joint need for the chillers can be minimized.
for heat and cold water in order to maximize
the total efficiency of the plant. A power ENVIRONMENTALLY FRIENDLY COMFORT
plant located close to the consumer has As living standards improve, demands for
lower electricity distribution losses and safer better comfort tend to increase along with
distribution due to short distribution lines. greater awareness of environmental issues.

4
Separate electricity and heat generation
10 MWe, heating mode
11 MWe, cooling mode

Fuel imput 23 MWf, heating mode 1 MWe,


25.3 MWf, cooling mode 10 MW e
cooling mode

5 MW c
Compressor
chiller
7.8 MW h Terminal
Boiler

Additional fuel 8.76 MWf


Total efficiency, heat mode 56%
Total efficiency, cooling mode 59%

Trigeneration: power generation, heat generation and absorption cooling.

Fuel input 23 MWf Additional fuel


10 MW e
to compr. chiller
0 MWf
Up to 5 MW
Chilling
system
Heating Terminal
system 7.8 MW h

Total efficiency, heat mode 77%


Additional fuel to aux. boilers 0 MWf
Total efficiency, cooling mode 65%

The main advantage of trigeneration is shown in this diagram. With a Wärtsilä trigeneration power plant
you will obtain the same output with considerably less fuel input than with separate power and heat
generation.

NICE AND WARM.

This leads to a more widespread use of air Electricity


conditioning, and awareness of environmental
issues calls for more efficient use of fuel.
Wärtsilä Power Plants has ready-made
MW

solutions for trigeneration which can be


easily adapted to the specific needs of the Emergency level
aviation market and delivered within tight time
schedules. Year
Engine 1 Engine 2 Purchase

Electricity 44% Recoverable heat 50% Heating and cooling


MW

Heating
Cooling Year
Losses 6%

Natural gas 100% Engine 1 Absorption chiller Boilers


Engine 2 Compressor chiller

Principal heat balance of a Wärtsilä gas engine. Trigeneration enables optimized plant operation around the year and
guarantees both airport safety and comfort in all occurring situations.
5
Fast delivery, stepwise expansion, high plant Wärtsilä is a major global provider of
efficiency and true flexibility make Wärtsilä decentralized power plants for utilities, IPPs,
power plants a sound choice in today’s cost- industry and municipalities. The modular
conscious power market. It is the choice that design of the plants enables fast-track delivery
allows you to focus on the essential in your anywhere in the world, typically less than 7
own core business: treating your passengers months.  Prefabricated, functionally pretested
to a safe, smoothly operating airport with a modules guarantee consistent quality and
constantly enjoyable climate. performance and make on-site installation
simply a matter of assembling and connecting
the modules.
Wärtsilä has the resources and capabilities
needed to carry out deliveries ranging from the
supply of equipment and basic engineering to
complete turn-key projects including financing,
engineering, procurement, construction,
operation and maintenance.
You can rest assured that you have the best
possible support available when and where
you need it  - from training and online support
to service packages or plant modernization
and upgrading. Wärtsilä’s global network is on
hand 24 hours a day to ensure that your power
plant performs at its highest efficiency and
performance levels throughout its lifetime.

GLOBAL.

LINATE AIRPORT, ITALY


In June 2007, Wärtsilä and EuroPower SpA round electrical power output of 24 MWe.
handed over a 24 MWe trigeneration power The heat recovery system for the three
plant at Linate airport, Milan in Italy. The engines is designed for maximum heat
plant has been built for Malpensa Energia recovery for heating services and the air
Srl, whose shareholders are the Milan airport conditioning of airport buildings. This full
management company SEA Aeroporti Milano climate control system is typically referred to
and the Milan multi-utilities company AEM as a trigeneration installation.
Milano. The heat is delivered as superheated water
The trigeneration power plant is equipped at 125°C and hot water at 70°C to the airport
with three Wärtsilä 20V34SG gas-fuelled buildings and to a small village close to the
generating sets, together with ancillary airport. The plant also delivers electricity to the
equipment, exhaust heat recovery economizers Italian national grid. Normally the generating
and two gas-fired boilers. The plant is located sets run in parallel with the grid but they will
inside Linate airport. also serve as emergency sets to maintain
Operating on baseload, the plant is flexible airport services in the event of a break in the
in operation, economically meeting the grid supply.
variations in heat demand in summer and •• engines.....................3 x Wärtsilä 20V34SG
winter for both heating and air conditioning. •• total electrical output................. 24000 kWe
The heat output of the plant is 81.7 MWth in •• total heat output. ..................... 17505 kWth
winter and 74.8 MWth in summer, with a year- •• total efficiency................................ 80.2 %

6
BARAJAS AIRPORT, SPAIN 18V32DF dual-fuel engines and their
In 2003, AENA, the Spanish Airport Authority, auxiliaries, the heat recovery boilers at the
called for bids to supply thermal and electrical engine’s exhaust, the engine hall ventilation
energy for the very important Barajas airport systems and the engine control system.
in Madrid under a Power Purchase Agreement The 18V32DF burns natural gas as the main
for a twenty-year period. One of the bidders, fuel and light fuel oil (LFO) as the back-up
the engineering company Sampol Ingeniería y fuel. Engine emissions comply with the local
Obras S.A, teamed up with Wärtsilä to develop environmental laws and the design and
a technically advanced, environmentally construction with the Spanish and European
friendly and cost-efficient trigeneration plant engineering and construction standards as well
that would guarantee the extremely high level as the airport’s own stringent regulations.
of reliability required. The trigeneration plant generates a net electric
Wärtsilä presented an offer based on the EPC power of 33 MW and is connected to both
(Engineering, Procurement and Construction) the airport’s internal grid and the public grid.
approach. Wärtsilä’s strong technological The plant provides electricity on a continuous
support along with Sampol’s price-competitive basis, as well as heating during the winter and
offer made the team the bid winner for the new cooling during the summer.
trigeneration plant. •• engines..................... 6 x Wärtsilä 18V32DF
Wärtsilä was responsible for supplying •• total electrical output................. 33600 kWe

LOCAL. the engineering, equipment, installation,


commissioning and start-up of six Wärtsilä
•• total heat output. ..................... 24000 kWth
•• total efficiency.................................... 74%

DETROIT AIRPORT, NICE AIRPORT, SØNDRE STRØMFJORD AIRPORT,


USA FRANCE GREENLAND
•• engines.....................3 x Wärtsilä 18V34SG •• engines....................... 2 x Wärtsilä 12V200 •• engines........................2 x Wärtsilä 6L20 +
•• total electrical output................. 16200 kWe •• total electrical output................... 4600 kWe . ..................................... 1 x Wärtsilä 9L20
•• total heat output. ....................... 7300 kWth •• total heat output. .......... no heat is produced •• total electrical output................... 3140 kWe
•• total efficiency.................................... 57% •• total electrical efficiency at •• total heat output. ....................... 2200 kWth
Wärtsilä’s gas power plant at the Detroit Metro generator terminals, cos phi 0.8........ 38.0% •• total efficiency.................................... 73%
Airport supplies heat and power to its Midfield Nice airport is an emergency power plant. The plant is the only power source (baseload)
Terminal expansion. The power plant’s owner, No heat is produced. Total efficiency is only for the airport. Kangerlussuaq Airport serves
Metro Energy LLC, sells excess electric energy electrical efficiency : 38.0%-0%, at generator as an Atlantic emergency airport. Due to its
to the national grid. terminals, cos phi 0.8. geographical location the airport is closed only
1 or 2 days a year because of bad weather.

7
01.2007 / Bock´s Office /
Wärtsilä enhances the business of its customers by providing them with
complete lifecycle power solutions. When creating better and environmentally
compatible technologies, Wärtsilä focuses on the marine and energy markets
with products and solutions as well as services. Through innovative products
and services, Wärtsilä sets out to be the most valued business partner of
all its customers. This is achieved by the dedication of more than 14,000
professionals manning 130 Wärtsilä locations in close to 70 countries around
the world.

WÄRTSILÄ® is a registered trademark. Copyright © 2007 Wärtsilä Corporation.

Potrebbero piacerti anche