Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
BACK
Innovative
Car Alarm
Thatcham M.I.R.R.C. Evaluation No:
TC2-1238/1101
COBRA 7518
High Security Dynamic Radio Key Alarm and Immobiliser system with back-up battery and self-adjusting
ultrasonic movement detectors and central door lock switching facility.
Suitable for 12v DC negative earth power supply.
IMPORTANT
1. The Cobra 7518 alarm system MUST be fitted with a previously installed Category 2 M.I.R.R.C. listed
immobiliser to obtain Category 1 status for the vehicle's security systems. If there is no Category 2
Thatcham listed immobiliser fitted along with associated V.S.I.B. installation certificate, Category 1
status cannot be claimed on fitment of the alarm.
2. The Cobra 7518 is a stand-alone alarm system and MUST NOT be connected in any way to an existing
immobiliser.
3. The Cobra 7518 MUST NOT take its power supply from the same circuit as the existing immobiliser and
not interfere in any way with the immobiliser cut circuitry.
4. Where the existing immobiliser is connected to visual indicators the Cobra 7518 MUST NOT be
connected to visible indicators at all. Therefore the two yellow wires are not used and must be insulated.
Kit Contains:
l User Manual
l 1 x Bonnet Switch
l Wiring Harness
l 2 x Window Stickers
FUNCTIONS
display trigger codes if the alarm has been
triggered in your absence.
l Ultrasonic exclusion.
INSTALLATION NOTES
Alarm Unit:
l Mount the alarm unit with the screws provided
(5mm hole) in a suitable position in the engine
compartment. Ensure that it is not exposed to
water or mounted too close to heat generated by
the exhaust and cooling systems.
Wiring Diagram
Diagram 1
WIRING:
Note: Disconnect the battery before you start wiring. Refer to diagram 1 and connect as follows:
Black wire: Negative feed wire (-31)
Green/Red wire: Ignition sense wire (Ignition feed
Connect to an existing ground point on the vehicle.
+15) - Connect to a feed which is live (positive)
Red wire: 12v positive feed wire (+30)
while the ignition is switched to the On' position and
Connect to the inlet side of the fuse box, through
remains live while cranking the starter motor.
the 15A fuse provided.
Pink wire: NOT USED
Blue Wires x 2: Direct contact circuit wires
Yellow wires: Indicator (flasher) wires
Connect to the bonnet and boot switches.
Connect one Yellow wire to the right hand and the
Blue/Pink wire: Direct contact circuit wire
other to left hand positive (+) feed wire of the traffic
Connect to drivers door switch.
indicator lamps. These connections should be made
Green wires: Immobilisation Circuit optional (12.75
inside the vehicle.
amp max) - If the vehicle has an electrical fuel pump,
Black/White wire: LED negative feed wire
cut the ignition trigger wire to the fuel pump relay
Connect to the Black wire on the LED.
and connect one Green wire to each cut end. This
circuit can also be used to cut the feed wire of a
Grey wire: Accessory trigger wire
rotary diesel pump or the starter motor solenoid
Connect to the trigger wire of any optional sensors
feed.
you are fitting.
Where the vehicle does not have an electric fuel
Brown wire: Switched negative output.
pump the vehicle's ignition system can be cut, but
This wire becomes negative when the alarm is armed
extreme care should be taken.
and is used for switching On/Off optional
(This immobilisation circuit is not polarity sensitive).
accessories such as sunroof and window closers.
Control/Siren
Unit Mounting
Diagram 2
Diagram 3
LED
Black wire: LED negative feed wire
Connect to the Black/White wire on the alarm
harness.
Red wire: LED 12v positive supply
Connect to the Red wire on the fused side of the
alarm harness.
Diagram 4
3
Diagram 5
Diagram 6
Diagram 7
Diagram 8
Securing The
Harness
Cover
INSTALLATION NOTES
Note:
i All Remote keys required to operate the alarm
system must be programmed at the same time. This
includes all existing Remote/Touch keys as well as
new keys. Any Remote/Touch keys not
reprogrammed at this point will not operate the
alarm system.
ii
Programming:
A
B
C
D
E
F
G
H
=
=
=
=
=
=
=
=
1 flash
2 flashes
3 flashes
4 flashes
5 flashes
6 flashes
7 flashes
8 flashes
1 second
1 second
24 seconds
controlled by large remote button
1 second
1 second
24 seconds
controlled by large remote button
Voltage Drop
Sensing
ON
ON
ON
ON
OFF
OFF
OFF
OFF
Turn the ignition OFF and back ON. This will enter you into Program Selection Table 2'. The LED will confirm
this by dislaying 2 long pulses. A short pulse from the LED will then identify that you are at Mode A of Program
Selection Table 2
Programming Program Selection Table 2:
Push button 1 on the Remote key to change the selection (pushing the button 4 times will take you to Mode E
of Program Selection Table 2). The LED will confirm this by flashing 5 short pulses.
If you are happy with this selection press button 4 on the Remote key. The LED will confirm your selection by
flashing in long pulses.
Program Table 2:
Mode
A =
B =
C =
D =
E =
F =
G =
H =
I =
J =
K =
L =
1 flash
2 flashes
3 flashes
4 flashes
5 flashes
6 flashes
7 flashes
8 flashes
9 flashes
10 flashes
11 flashes
12 flashes
Auto Re-arm
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
continuous
intermittent
controlled by large remote button
continuous
intermittent
controlled by large remote button
continuous
intermittent
controlled by large remote button
continuous
intermittent
controlled by large remote button
Turn the ignition OFF and back ON. This will enter you into Program Selection Table 3. The LED will confirm
this by displaying 3 long pulses.
Programming Program Selection 3 - Buzzer Volume:
Pres button 1 on the Remote key to increase the buzzer volume and button 4 to decrease the volume. If you
decrease the volume to minimum setting the buzzer will not sound when the alarm system is armed/disarmed.
Turn the ignition OFF. This will exit you from the programming feature.
6
TECHNICAL SPECIFICATION
Rated supply voltage .................................................................................................................................... 12v DC
Operating voltage .................................................................................................................................... 9 / 16v DC
Quiescent current draw - disarmed state ....................................................................................................... < 9 mA
Quiescent current draw - armed state ......................................................................................................... < 13 mA
Operating temperature ........................................................................................................................-40 / +105C
Acoustic output (Siren) .............................................................................................................. > 118dB (A) @ 1m
Optional interrupt circuit .............................................................................................................................. 12.75 A
Siren duration ..................................................................................................................................................... 30"
CDL pulse time (open & close) .............................................................................................................................. 1"
CDL circuit rating ................................................................................................................................................. 5A
Remote key frequency ........................................................................................................................... 433.92Mhz