Sei sulla pagina 1di 59

Ivar Aasen Field Development Project pdQ

David Stone

28.05.2015

06L

05.05.15

As Built

DSF

EsFr

HFO

05L

17.03.15

As Built

EsFr

HFO

StWe

04L

14.11.14

As Built

EsFr

HFO

StWe

03I

15.07.14

Issued for construction

EsFr

HFO

StWe

02E

13.06.14

Issued for review

EsFr

HFO

StWe

Rev.

Date

Prepared
by

Reviewed
by

Approved

by

Reason for Issue

110 KV SWBD CIRCUIT/WIRING DIAGRAM, FEEDER TO

TRANSFORMER 80ET0100A

Package Title:

EICT Package

Area
Code:

System

Code:

M120

80

Project Tag Numbers:

80EC0503

No. of

Pages:

59

Project No.:

Supplier Document Number:

Rev.

C-00011

1
51PO-04193.210-K-102-00

06L

Purchase Order No:

Project Document Number:

Proj Rev.

1
DN02-S09011-E-XK-1002-00

06L

S09011

<1>

1
Item

Description

Page

Item

Page

Description

1.

Table of content

30.

Trip signals to/from 1 1 kV SWBD Incomer

30

2.

Single line drawing

31 .

Signals to generator control panel

31

3.

Control voltage overview and distribution

32.

Breaker/Switch status to bus bar differential

32

4.

Control voltage distribution

33.

Condition monitoring, Gas density sensors

33

5.

Busbar A/B voltage measurement

34.

Capacitive voltage indicators

34

6.

Cable voltage measurement

35.

Transformer Guard, Power and communication modules

35

7.

Disconnector Q61 for voltage transformer T5

36.

Transformer Guard, I/O module

36

8.

Current measurement from 11 kV SWBD and NER

37.

Transformer Guard, I/O module

37

9.

Current transformer T1 core 1 , 2, 3

38.

Transformer Guard, I/O module

38

1 0.

Current transformer T1 core 4

10

39.

Transformer Guard, I/O module

39

1 1.

Control voltage distribution

11

40.

Transformer Guard, Termperature module

40

1 2.

Control voltage distribution, cabinet light

12

41 .

Arc detection sensors

41

1 3.

Control voltage and commands, Circuit Breaker Q0

13

42.

Voltage/current measurement unit (PAC 3200)

42

1 4.

Direct trip signals to Circuit Breaker Q0

14

43.

Overview diagram, Siprotec module 1 and 2

43

1 5.

Trip circuit supervision

15

44.

Overview diagram, Siprotec module 3 and 4

44

1 6.

Control voltage and commands, Disconnector Q1

16

45.

Overview diagram, Siprotec module 5 and 6

45

1 7.

Control voltage and commands, 3-position switch QZ2

17

46.

Overview diagram, Circuit breaker Q0 part 1

46

1 8.

Control voltage and commands, Earth switch Q8

18

47.

Overview diagram, Circuit breaker Q0 part 2

47

1 9.

Control voltage and commands, 3-position switch QZ9

19

48.

Overview diagram, Circuit breaker Q0 part 3

48

20.

Heating

20

49.

Status switches, Circuit breaker Q0

49

21.

Signals to Siprotec, Breaker/switch positions

21

50.

Overview diagram, Disconnector Q1

50

22.

Signals to Siprotec, Breaker/switch positions

22

51 .

Status switches, Disconnector Q1

51

23.

Signals to Siprotec, Signals from CB Q0

23

52.

Overview diagram, 3-position switch QZ2

52

24.

Signals to Siprotec, SF6 pressure alarm/trip

24

53.

Status switches, 3-position switch QZ2

53

25.

Signals to Siprotec, Alarms and VTs online

25

54.

Overview diagram, 3-position switch QZ9

54

26.

Signals to Siprotec, VT MCBs and internal trip signals

26

55.

Status switches, 3-position switch QZ9

55

27.

Signals to Siprotec, External trip signals

27

56.

Overview diagram, Earth switch Q8

56

28.

Trip signals from SAS, ESD and PSD

28

57.

Status switches, Earth switch Q8

57

29.

Trip signals from Transformer

29

58.

Spare Terminals

58

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE

As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO

TRANSFORMER 80ET0100A

Table of content

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-01

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

01

DN02-S09011-E-XK-1002-01

+E03

Sheets:

58

<1>

3
Busbar A

110kV, 1250A, 40 kA(1s)

Busbar B

-Q1

-QZ2

GC01

-Y1 , Y2 shunt coils

GC02

-Q0

In: 1250A

P1

-T1
4
P2

L1,L2,L3:

400/1 A

2.5 VA Cl. 0.2FS5

5 VA Cl. 5P20

5 VA Cl. 5P20

5 VA Cl. 5P20

GC00

GC03

-QZ9

GC04

-T5

L1,L2,L3:

(90)110kV 110V

-Q61

GC05

3
3

10VA / Cl.0,2

10VA / Cl.0,2

-F1

-Q8

E
-Z1

Transformer feeder to 80ET0100A

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Single line drawing

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51 PO-041 93.21 0-K-1 02-02

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

02

DN02-S09011-E-XK-1002-02

+E03

Sheets:

58

<1>
+85EL0102A

<2>
+85EL0102B

Circuit 625

<3>

Circuit 625

< >
No. / Text

-K04

C 10A

I > I >

230 VAC Supplied from UPS A

230 VAC Supplied from UPS B

230VAC Changeover UPS supply

K04: Changeover Relay

F230.1 : Socket outlet supply

MCB

B1 : Insulation monitoring of

110 VDC bus

44

<5>

<6>

12

<8>

<7>

As Built

1 7.03.1 5

EsFr

EsFr
HFO

HFO

I >

As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Made by

Chc. by

SMOE

Appr. by

14
22
F230.1:4

/1 2.6

F6:3

/1 3.1

Acceptance Code:

Drawing Title:

Tag no.

P.O.Number

80EC0503

Wood Group

Mustang
Installation: Ivar Aasen Field

Development Project - PDQ Platform

/25.2

I >

/25.2

13
23

13
23

2
I >
1

14
24

F230.1:2

/1 2.6

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Control voltage overview and distribution


.

StWe

04L

Date

14
24
1
Supplier

C 6A

F6:1

/1 3.1

F5:3

/1 1 .6

DETNORSKE

Description

C 3A

F5:1

/1 1 .6

F4:3

/1 1 .4

DSF

I > I >

-F6

/25.3

C 3A

F4:1

/1 1 .4

05.05.1 5

13
23
14
24

-F5

/25.3

I > I >

C 3A

As Built

13
23
14
24

/25.2

2
1

I > I >

-F4

13
21

1
I >
2

F6:4

/04.1

F3:3

/1 1 .2

Issue

1 1 0VDC Supplied from UPS

F6: Spring charge Circut

breaker Q0 MCB

F6:2

/04.1

F3:1

/1 1 .1

C 3A

05L

110VDC Supplied from UPS

F5: Trip coil 2 supply MCB

/25.1

11

14
/25.1

PE

-V2

-F3

06L

-K04
-K04

/.5
/.5

-F230.1

110VDC Supplied from UPS

F4: Trip coil 1 supply MCB

32

44

Bender IR125Y-4

21

14

/25.1

-V1

Type of wire: Radox

14

/25.1

-B1

13

/25.1

110VDC Supplied from UPS

F3: Instrument supply MCB

110VDC

110VDC

L2

-K04

/.5

22

13

/25.1

14

/25.1

L1
-U4

13

13

/25.1

L2

14

14

/25.1

L1
-U3

A-

13

/25.1

L2

-U2

-K04
/.5

A+

L1

L2

R2

L1
-U1

R1

<4>

31

43

A2

-K04

/.5

A1

I > I >

32

14
24

14
24

-F2

/25.1

C 10A

22

13
23

14

/25.1

1
-F1

-X230

13
23

-X230

Yard cable

Yard cable

13

/.6

21

/.7

31

/.7

43

/.7

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-03

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

03

DN02-S09011-E-XK-1002-03

Sheets:

58

<1>

<2>

<3>

<4>

<5>

<6>

+82EL0123

<>

Circuit 602

F6:2
/03.6

1 1 0VDC Supplied from UPS

F7: disconnector switch Q1

motor and operation supply

MCB

1 1 0VDC Supplied from UPS

F8: 3-postition switch QZ2

motor and operation supply

MCB

1 1 0VDC Supplied from UPS

F9: Earthing switch Q8


motor and operation supply

MCB

1 1 0VDC Supplied from UPS

F10: 3-postition switch QZ9

motor and operation supply

MCB

1 1 0VDC Supplied from UPS

F11: Trafoguard supply MCB

230 VAC Supplied from Main

For heating and light

Yard cable

I >
I

I >

F7:1
/1 1 .4

F8:1
/1 1 .6

F7:3
/1 1 .4

F9:1
/1 1 .4

F8:3
/1 1 .6

F1 1:1
/35.1

F10:1
/1 1 .6

F10:3
/1 1 .6

F9:3
/1 1 .4

14
22
/25.2

C 6A

/25.2

I > I >
1

C 3A

-F230.2

14
24

-F11

13
23

13
23
/25.2

14
24

4
3

I > I >

C 3A

I > I >

13
23
14
24

-F10

/25.2

2
C 3A

/25.2

13
23
14
24

-F9

I > I >

2
C 3A

I > I >

C 3A

-F8

-F7

14
24

13
23

13
21

-X230

F6:4
/03.6

/25.2

Type of wire: Radox

110 VDC

No. / Text

F230.2:2

/1 2.2

F1 1:3
/35.2

F230.2:4

/1 2.2

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Control voltage distribution


.

StWe

04L

Tag no.

Signature:

5
28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-04

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

04

DN02-S09011-E-XK-1002-04

Sheets:

58

<2>

<1>

<3>

Inter connection terminals

<>

Details shown in document:

No. / Text

DN02-S09011-E-XK-1 006-01

110 V AC Busbar Voltage

voltage from ringloop

Busbar voltage MCB

Busbar B

Busbar voltage MCB

Busbar A

110V AC, 60HZ


VOLTAGE

BUSBAR A L1

2
L2

3
L3

B
B

B
B

I >

I >

I >

13
21

-XR1 1

1 1 0V AC, 60HZ

A 1 A

/26.3

14
22

-F158

-XR1
5

VOLTAGE

BUSBAR B L1
6

L2

L3

I >

I >

I >

/26.4

14
22

-F159

A 1A

13
21

A8

U4

Siprotec 7UT85

A12

U5

Siprotec 7UT85

A7

-F21.3

/44.1

A11

-F21 .3
/44.1

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Appr. by

Wood Group

Installation: Ivar Aasen Field

Mustang
Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Busbar A/B voltage measurement

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-05

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

05

DN02-S09011-E-XK-1002-05

Sheets:

58

<2>

<1>

<3>

<4>

+80EH0500+E03

<>

2a2
4

Cable voltage transformer

core 1 110 kV/ 110 VAC

Class 0,2 star-star

Cable voltage to

Siprotec protection relay

Voltage for sync check

Cable voltage transformer

core 1 110 kV/ 110 VAC

Sync voltage for premag

to ESS A generator control

panel 82JC0001

2n

2a1
3

2a2
6

2n

2a1
5

2n

33

31

22

23

21

12

32

2a2

-X720

13

11

33

31

32

22

23

21

13

11

-X710

E03-W703
7x4 sq mm

12

B
+80EH0500+S03

2a1
E03-W702

7x4 sq mm

-T5L3

-T5L2

1a2
4

1n

1a1
3

1n

1a2
6

-T5L1

E03-W703
7x4 sq mm

-T5L3
1a1

1a2
2

1n

1a1
E03-W701
7x4 sq mm

-T5L2

-T5L1

A
B

No. / Text

Cable voltage transformer

core 2 110 kV/ 110 VAC

Cable voltage to PAC3200

multimeter

Cable voltage transformer

core 2 110 kV/ 110 VAC

Spare

13
21

I >

/25.7

6
A

41

31

-X722

21

14
22

13
21
B

I >

11

31

I >

A
B

A
B

16

-XT5

15

14

13

12

-XT5

11

10

-XT5

-XT5

Yard cable

Yard cable

14
22
4

C 3A

I >

41

2
-X721

-F722

/25.6

I >

I >

21

41

C 3A

11

14
22

-F721

/25.5

I >
6

I >

13
21

1
-X712

I >

31

/25.4

C 3A

21

41

I >

31

11

-X711

I >

21

I >

C 3A

-F712

14
22

-F711

11

13
21

Yard cable

A5

U3

U2

A
B

A
B

+82JC0001

A3

A1

XT5:9

/42.4

-X

U1

XT5:1 0
/42.4

A
B

XT5:1 1

/42.5

A6

A4

A2

Siprotec 7UT85

-F21.3
/44.1

XT5:12
/42.5
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

DETNORSKE

As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Appr. by

Tag no.

Wood Group

Mustang
Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO

TRANSFORMER 80ET0100A

Cable voltage measurement

StWe

04L

Drawing Title:

Supplier

HFO

Acceptance Code:

Signature:

David Stone

28/05/15
=

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-06

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

06

DN02-S09011-E-XK-1002-06

+E03

Sheets:

58

<1 >

<>

Cable voltage transformer T5

isolator switch status

Isolating link not in

Isolating link in

Isolating link not in

X1:13
GY
BL
X1:14

X1:7
BN

BK

/25.6

/25.6

X1:8

X1 :9
GY
BL
X1:10

X1:3
BK
BN
/25.4

X1:4

X1:15
GY
BL
X1:16

X1:5
BK
BN
X1:6

X1:11
GY

-BG2

BL

-BG1

X1:12

X1:1
BK

-BG4

BN

-BG3

X1:2

-T61

Isolating link for voltage


transformer T5

/25.4

Isolating link in

Isolating link not out

Isolating link out

Isolating link not out

Isolating link out

+80EH0500+E03

No. / Text

-BG1, -BG2 is shown in deactivated position

-BG3, -BG4 is shown in activated position

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

StWe

DETNORSKE
04L

As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

P.O.Number

80EC0503

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Disconnector Q61 for voltage transformer T5


Overview diagram

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-07

Installation: Ivar Aasen Field

Development Project - PDQ Platform

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

07

DN02-S09011-E-XK-1002-07

+E03

Sheets:

58

<1>

<2>

<>

Current measurement from

incomer K03 in 11 kV SWBD

80EH0011A

Current measurement from

Neutral Earth Resistor

80EY0100A

-X

331

332

312

-X1

322

=80EY0100A

=80EH0011A
+K03

No. / Text

A
B

A
B

A
B

-X32

Yard cable

Yard cable

B7

B5

I 8
B8

B3
I 6

I 7
B6

B2

B4

-F21.1

/43.1

B1

F21.1:B1

I 5

/35.4

X32:1

Siprotec 7UT85

/35.4

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Current measurement from 11 kV SWBD and NER


.

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-08

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

08

DN02-S09011-E-XK-1002-08

Sheets:

58

<2>

<1>

<3>

<>
+80EH0500+E03

-T1L1

-T1L1

-T1L1

L1

Current Transformer

Measurning current, Core 1

400/1A 2,5VA Cl. 0,2Fs5

measuring current to PAC3200

Current Transformer

Protective current, Core 2

400/1A 5VA Cl. 5P20

protection current to

Siprotec 7SJ85

Current Transformer

Protective current, Core 3

400/1A 5VA Cl. 5P20

protection current to

Siprotec 7SS85

Bus Bar Differntial IED in

cubicle E03

3S1

3S2

2S1

2S2

1S1

1S2

-T1L2

-T1L2

-T1L2

L2

-T1L3

3S1

3S2

2S1

2S2

1S1

1S2

-T1L3

-T1L3

L3

E03-W603

7x4 sq mm

3S1

3S2

E03-W602
7x4 sq mm

2S1

2S2

B
A

B
A

49

41

11

21

31

-X630

32

22

12

49

41

11

21

31

std 4 sq mm

-XT1

A
B

A
B

A
B

A
B

310

311

321

331

332

322

312

-XT1

Yard cable

210

211

221

110

111

121

131

132

Yard cable
122

Yard cable
112

std 4 sq mm

231

32

-X620

22

12

49

232

41

11

21

std 4 sq mm

-XT1

222

212

31

32

-X61 0

22

+80EH0500+S03

12

1S1

1S2

E03-W601
7x4 sq mm

No. / Text

XT1:112

/42.3

std 4 sq mm

A7

A5

A1

A3

I 4

-XR2

A8

I 3

I 2

A6

XT1:121

/42.3

A4

DN02-S09011-E-XK-1 006-01

A2

XT1:131

/42.4

Inter connection terminals

Details shown in document:

I 1

-F21.1

/43.1

XT1:132
/42.4

Siprotec 7UT85

XT1:122

/42.3

XT1:111

/42.3

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr

HFO

Drawing Title:

Supplier

HFO

StWe

DETNORSKE
04L

As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

SMOE

Wood Group

Mustang

Chc. by
Appr. by

Tag no.

P.O.Number

80EC0503

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Current transformer T1 core 1 , 2, 3


.

Area:

Scale

Siemens Dwg. No.:

M1 20

NA

51PO-04193.210-K-102-09

Installation: Ivar Aasen Field

Development Project - PDQ Platform

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

09

DN02-S09011-E-XK-1002-09

+E03

Sheets:

58

<1>

<>

No. / Text

-T1L1

+80EH0500+E03

L1
4S1

4S2

Current Transformer

Protective current, Core 4

400/1A 5VA Cl. 5P20

Spare

-T1L2

L2

4S1

4S2

-T1L3

L3

49

41

11

21

31

32

-X640

22

+80EH0500+S03

12

4S1

4S2

E03-W604

7x4 sq mm

std 4 sq mm

A
B

410

411

A
B

421

431

A
B

432

-XT1

422

412

Yard cable

A
B

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Current transformer T1 core 4


.

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-10

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

10

DN02-S09011-E-XK-1002-10

Sheets:

58

116
117
118
119

110
111
112
113

107
108
109

X30:1 08

/26.4

114

105
106

100
101
102
103

104

X30:1 1 2 B

X30:55

/29.4

X30:56

Control Voltage Shunt coil 1

and close coil

110 VDC

Control Voltage Shunt coil 2

110 VDC

Control Voltage disconnector

switch Q1

110 VDC

Control Voltage 3-position

switch QZ2

110 VDC

Control Voltage Earthing

switch Q8

110 VDC

Control Voltage 3-position

switch QZ9

110 VDC

X30:57

X30:58

/29.6

/04.2

X30:116

/1 3.6

X30:127

/1 6.4

/1 7.3

/1 7.6

130

136

/1 7.1

1 37

X30:126

/1 6.2

-X30

138

139

X30:123 B

-X30

131

/1 6.6

127

X30:122 B

/1 6.4

X30:121 B

122

/1 6.2

F8:3

132

-X30

/04.3

133

F8:1

126

120

121

-X30

F7:3
125

F7:1

/30.3

/04.2

135

/04.1

X30:131 B

X30:132 B

X30:133 B

Control Voltage distrubution

110 VDC

<5>

/42.5

No. / Text

<4>

X30:136

/1 7.1

X30:137

/1 7.3

<6>

<7>

/04.3
F9:1

B
B

-X30
B

/1 8.2

/1 8.4

/1 8.6

/04.4

/04.4
F9:3

F1 0:1

-X30

X30:141 B

X30:1 42 B

X30:143 B

-X30
B

X30:146

/1 8.2

/1 9.1

X30:147

/1 8.4

/1 9.3

/1 9.6

/04.5

F1 0:3

-X30

X30:151 B
X30:152 B
X30:1 53 B
B

X30:1 56

/1 9.1

X30:157

/1 9.3

Acceptance Code:

1
06L
As Built
05L
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

StWe

04L
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I
Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO

TRANSFORMER 80ET0100A

Control voltage distribution

DETNORSKE

Issue
Description

156

/14.2

157

X30:20

X30:107

/1 3.3

158

X30:1 1 1 B

159

X30:19

/1 3.6

-X30

134

X30:106

/1 3.4

1 50

X30:18

151

-X30

<>

F5:3

152

X30:17

/03.4

153

154

X30:16

X30:104 B

128

129

X30:1 5

/1 4.2

145

/29.2

X30:1 03 B

146

X30:14

X30:54

/1 3.2

147

/26.3

X30:102 B

123

59
60
61
62
63

X30:1 3

X30:53

/1 3.5

124

50
51
52
53
54
55
56

1
3
4

5
6

7
8
9
10

/26.1

148

/26.6

X30:1 2

X30:52

/1 3.4

F5:1

149

/26.5

/21 .2

X30:1 01 B

140

/27.5

X30:11

X30:51

-X30

141

/42.5

142

X30:10

-X30

143

/30.1

/03.4

F4:3

144

/29.4

X30:9

64

/29.2

65

/27.4

X30:8

66

/27.3

67

/27.2

X30:7

68

11

/27.1

X30:6

12

/29.6

13

/26.4

X30:5

14

/26.3

15

/26.1

X30:4

16

/25.3

17

X30:3

-X30

18

/25.2

19

/25.1

X30:2

F4:1

20

/21 .2

-X30

6
<3>

/03.3

/03.3

F3:3

57

F3:1

/03.1

58

/03.1

<2>

115

<1>

155

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M1 20

NA

51PO-04193.210-K-102-11

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

11

DN02-S09011-E-XK-1002-11

+E03

Sheets:

58

<1>
/04.7
F230.2:2

4
<2>

<3>

6
<5>

<4>

/04.7

/03.7

F230.2:4

F230.1:2

<6>

<7>

/03.7

<>

/.6

X101:7

/.7

/.5

Control Voltage distrubution

230 VAC from Main

Heater Low voltage control

cubicle with thermostat

230 VAC

Light Junction box

with door switch

230 VAC

Light Low voltage control


cubicle with door switch

230 VAC

Control Voltage distrubution

230 VAC from UPS

Heater Low voltage control

cubicle with thermostat

230 VAC

Socket outlet
230 VAC UPS

B
-X230

-X230

/.1

43

A
B

-X100

+80EH0500+S03

+80EH0500+S03

A
B

X1 00:3

/.1

X1 00:4

/.6

-S1 01

43

X101:7

E03-W07

47x1,5 sq mm

-R101

-S1 00

-T1

/.5

X07:43

+80EH0500+E03

Yard cable

-X202

6
7

1
2

9
10

B X100:9

X101 :2

B X100:8

/.6

10

X1 00:4

B X1 00:7

/.3

-X101

/.6

X1 00:3

/.5

-X101

7
8

-X100

A
-X100

No. / Text

F230.1:4

-E1 01

-E100

PE

-X1 02

L2

2
142

/20.1

-R100

L1

141

X1 01 :2

-Q0_4

/49.4

B
A

-X100

X07:44

X202:6

44

+80EH0500+S03

-X202

44

E03-W07
47x1,5 sq mm

X100:8
/.2

X1 00:9

/.2

Yard cable

-X230

X202:44

/20.1

X100:7

/.2

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Control voltage distribution, cabinet light


and socket outlet

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-12

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

12

DN02-S09011-E-XK-1002-12

+E03

Sheets:

58

Yard cable

B
A

D6

D4
A

B
A

-X4

/1 4.1

X4:2
/1 5.6

X4:3

B
B
B
B
3

F21 .1:D6

X30:207

/1 5.3

207

206

205

204

203

202

201

200

No. / Text

CB Q0 spring charge motor

110 VDC

Reset blocked motor Q0

Breaker operation counter Q0

Shunt trip 1 with trip

circuit supervision CB Q0

Close coil CB Q0

Shunt trip 2 with trip

circuit supervision CB Q0

/1 5.5

208

-X3

-X30
B

BO 1 .3
F

/1 4.1
X3:2
/1 5.3

X3:3

F21.1:D2

/1 5.2

D5

BO 1.2
F

<>

F21 .1:D5

/1 5.5

D3

D1
BO 1.1

D2

Siprotec 7UT85

-H10

-S1

-F21 .1

/43.1

X30:1 1 1

/1 1 .5

X30:102

/1 1 .3

F21.1:D1

/1 5.2

F6:1

/03.6

7
<6>

X30:210

/1 5.6

210

X30:101

/1 1 .3

F6:3

/03.6

6
<5>

<4>

4
<3>

209

<2>

2
<1>

DC

-X202

30

28

E03-W07

47x1,5 sq mm

X07:28

X07:30

26

26

30

X06:26

30

E03-W06

47x1,5 sq mm

X06:30

28

28

13

-X201

X06:28

E03-W07

47x1,5 sq mm

13

X07:13

12
12

X07:12

23

23

22

X06:23

-Q0_1

/46.4
/46.4

60s

A1

-KK4

A2

A2
27 X06:27

29 X07:29

A1

X06:2
2

A2

X06:1
E03-W06

47x1,5 sq mm

Control Voltage

-KK1

29 X06:29

-KK3

A1

4
X06:4

-X202

A1

22
-Q0_2

/47.4

/47.4

A2

A
B

E03-W06

47x1,5 sq mm

+80EH0500+E03

-Q0_1

/46.4

/46.4
-M1

X06:3

X06:22

-X201

+80EH0500+S03

E03-W07

47x1,5 sq mm

-X202

29

27

29

-X201

+80EH0500+S03

06L
05L

As Built
As Built

05.05.1 5
DSF
1 7.03.1 5
EsFr

X30:107

/1 1 .4

EsFr
HFO

X30:1 06

/1 1 .4

HFO

DETNORSKE
1 4.1 1 .1 4
EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4
EsFr

HFO

StWe

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

215

A
B

X30:116

/1 1 .6

Acceptance Code:

Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Control voltage and commands


Circuit breaker Q0

StWe

As Built

Drawing Title:

Supplier

04L

Issue

214

213

212

-X30
X30:103

/1 1 .3

211

Yard cable

Signature:

David Stone

28/05/15
=

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-13

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

13

DN02-S09011-E-XK-1002-13

+E03

Sheets:

58

<1>

L+ 110 DC

X30:104

<2>

<5>

<4>

<3>

<6>

<7>

<8>

/1 1 .3

<>

13

-XR4

-XR1

Arc detection

-XR4

14

-XR1

11
7
-K08

/30.3

-K07
/29.6
4

-K06
/29.4

12
8

12
8

12
8

D1

-BO 3.1

-K05
/29.2

D2

-K02.1
/28.5

Siprotec 7SS85

12
8

12
8
-K01.1
/28.3

B
X3:2

/1 3.5

L+ 110 DC

X30:112

<1 2>

<11>

<10>

-XR1

<13>

<14>

16

-XR1

Direct trip Shunt coil 1

Bus bar differential

Direct trip Shunt coil 1

Trafo temp High High

Direct trip Shunt coil 1

Buchholz

Direct trip Shunt coil 1

Overflux

Direct trip Shunt coil 1

Intertrip from 1 1 kV

Direct trip Shunt coil 1

Arc detection

Direct trip Shunt coil 2

ESD (Disabled)

10

Direct trip Shunt coil 2

PSD (Disabled)

11

Direct trip Shunt coil 2

Bus bar differential

12

Direct trip Shunt coil 2

Trafo temp High High

13

Direct trip Shunt coil 2

Buchholz

14

Direct trip Shunt coil 2

Overflux

15

Direct trip Shunt coil 2

Intertrip from 1 1 kV

X4:2

/1 3.7

05L

As Built
As Built

05.05.15
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO
StWe

04L

As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Description

Made by

Date

Chc. by

SMOE

Appr. by

Tag no.

Wood Group

Installation: Ivar Aasen Field

Mustang
Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Direct trip signals to circuit breaker Q0

Shunt coil 1 and 2

DETNORSKE

Issue

Acceptance Code:

06L

12
8
-K08

/30.3

13
9
-K07
/29.6

-K06
/29.4

13
9

13
9

D3

-BO 3.2

-K05
/29.2

D4

Siprotec 7SS85

12
8

12
8
4

-K02.2
/28.5

Direct trip Shunt coil 1

PSD (Disabled)

-K01.2
/28.3

<15>

+80EC0501

Direct trip Shunt coil 1

ESD (Disabled)

/1 1 .5

15

XR4:8
/26.4

<9>

+80EC0501

+80EC0501

No. / Text

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-14

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

14

DN02-S09011-E-XK-1002-14

Sheets:

58

<1>

<2>

<>

A
/1 3.4

F21.1:D1

/1 3.5

/1 3.6

F21.1:D5

/1 3.4

/1 3.6

F21.1:D6

A8

A7
BI 6.3

Circuit breaker Q0

Trip circuit supervision

Trip coil 2

110 VDC

BI 6.4

A6

A5

A4
X30:207
/1 3.5

Siprotec 7UT85

-F21.6

/45.4

BI 6.2

F21.1:D2

Circuit breaker Q0

Trip circuit supervision

Trip coil 1

110 VDC

X4:3

A2

A1
BI 6.1

A3

Siprotec 7UT85

-F21.6
/45.4

1
/1 3.7

X3:3

No. / Text

X30:210

/1 3.7

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

1 10 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Trip circuit supervision


Shunt coil 1 and 2

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-15

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

15

DN02-S09011-E-XK-1002-15

+E03

Sheets:

58

<1>

<2>

X30:126

/1 1 .4

<3>

<4>

X30:122
/1 1 .3

/1 1 .3

<>

No. / Text

Disconnector Q1

operation motor

110 VDC

Disconnector Q1

command off

110 VDC

Disconnector Q1

command on

110 VDC

Disconnector Q1

control voltage

110 VDC

X30:123

B12

B13
219

30

32

X1 :3

-Q1

/50.4

/50.4

-QA1

31

X1:31

X1:4

A2

-QA2

A1

DC

A2

-M1

A1

-Q1
/50.4

30

E03-W1

47x1,5 sq mm

220

B11
21 8
32

-X211

X1:30

+80EH0500+E03

+80EH0500+S03

B
A

Yard cable

X1 :6

X1:5

E03-W1
47x1,5 sq mm

-X30

BO 4.2

B
A

BO 4.1

X1:32

-X211

B
A

Yard cable

+80EH0500+S03

217

-X30

216

Siprotec 7UT85

-F21.4

/44.4

B14

X30:1 21
/1 1 .3

-X211

31

+80EH0500+S03

E03-W1

47x1,5 sq mm

B
A

-X30

221

Yard cable

Acceptance Code:

X30:127
/1 1 .4

06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO

TRANSFORMER 80ET0100A

Control voltage and commands

Disconnector switch Q1

StWe

04L

Tag no.

Signature:

5
28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-16

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

16

DN02-S09011-E-XK-1002-16

+E03

Sheets:

58

<1>

<2>

X30:136

/1 1 .6

<3>

<4>

<6>

<5>

X30:132
/1 1 .5

/1 1 .5

<>

No. / Text

X30:1 33

228

B
A

E03-W2A
47x1,5 sq mm

-X212

-X222

30

32

3-position switch QZ2

operation motor

110 VDC

3-position switch QZ2

command disconnector off

110 VDC

3-position switch QZ2

command disconnector on

110 VDC

3-position switch QZ2

command earthing switch off

110 VDC

3-position switch QZ2

command earthing switch on

110 VDC

3-position switch QZ2

control voltage

110 VDC

E03-W2B
47x1,5 sq mm

E03-W2A
47x1,5 sq mm

X1:3

X2:30

X2:32

X1:30

X1:32

X1:6

X1:5

+80EH0500+E03

-QZ2

/52.4

/52.4

-QA1

-X222

31

31

-X21 2

E03-W2A

47x1,5 sq mm

E03-W2B
47x1,5 sq mm

-X212

E03-W2A
47x1,5 sq mm
+80EH0500+S03

X1 :4

X2:31

X1:31

A2

-QA2

A1

DC

A2

-M1

A1

-QZ2
/52.4

1
C8
C7
227

C3
30

-X212

+80EH0500+S03

32

A
B

E03-W2A
47x1,5 sq mm

Yard cable

-X212

B
A

Yard cable

+80EH0500+S03

BO 4.6

226

-X30

225

BO 4.5

C5

BO 4.4

224

223

222

-X30

C6

C4

C2
BO 4.3

C1

-F21.4

/44.4

Siprotec 7UT85

X30:131
/1 1 .5

-X30

229

Yard cable

Acceptance Code:

X30:1 37
/1 1 .6

06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Control voltage and commands


3-position switch QZ2

StWe

04L

Tag no.

Signature:

David Stone

28/05/15
=

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-17

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

17

DN02-S09011-E-XK-1002-17

+E03

Sheets:

58

<1>

<2>

X30:146

/1 1 .4

/1 1 .3

<4>

<3>
/1 1 .3

X30:142

<>

No. / Text

Earthing switch Q8

command off

110 VDC

Earthing switch Q8

command on

110 VDC

Earthing switch Q8

control voltage

110 VDC

C13
B
A

32
X1:32

X1:30

X1:3

E03-W8

47x1,5 sq mm

-Q8

/56.4

/56.4

A1

-QA2

-QA1

31

X1:31

X1 :4

A2

DC

A2

-M1

A1

-Q8
/56.4

30

30

-X224

X1:6

X1:5

+80EH0500+E03

+80EH0500+S03

A
B

E03-W8
47x1,5 sq mm

B
A

32

A
B

Earthing switch Q8

spring charge motor

110 VDC

Yard cable

-X224

C12
-X30

Yard cable

+80EH0500+S03

C11

BO 4.8

234

BO 4.7

233

231

-X30

230

Siprotec 7UT85

-F21.4

/44.4

232

X30:141

/1 1 .3

C14

X30:143

-X224

31

+80EH0500+S03

E03-W8

47x1,5 sq mm

B
A

-X30

235

Yard cable

Acceptance Code:

X30:147
/1 1 .4

06L
As Built
05L
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
1 4.1 1 .1 4

EsFr

HFO

StWe

03I
Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue
Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO

TRANSFORMER 80ET0100A

Control voltage and commands

Earth switch Q8

StWe

04L
As Built

Tag no.

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-18

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

18

DN02-S09011-E-XK-1002-18

Sheets:

58

<2>

<1>
X30:156

/1 1 .6

<3>

<4>

<6>

<5>

X30:1 52

/1 1 .5

/1 1 .5

<>

No. / Text

242

-X223

E03-W9A
47x1,5 sq mm

A
B

-X213

3-position switch QZ9

command disconnector off

110 VDC

3-position switch QZ9

command disconnector on

110 VDC

3-position switch QZ9

command earthing switch off

110 VDC

3-position switch QZ9

command earthing switch on

110 VDC

3-position switch QZ9

command control voltage

110 VDC

30

32

30

-X213

+80EH0500+S03

32

3-position switch QZ9

operation motor

110 VDC

C3
B

241

C1
B

E03-W9B
47x1,5 sq mm

E03-W9A

47x1,5 sq mm

X1:3

X2:30

-QZ9

/54.4

/54.4

A1

DC

-QA1

A2

-QA2

A2

-M1

A1

-QZ9
/54.4

X2:32

X1 :32

X1:6

X1:5

X1:30

+80EH0500+E03

BO 5.4

240

C4

C2
BO 5.3

B13

B11
-X30

E03-W9A
47x1,5 sq mm

BO 5.2

Yard cable

-X213

B12

Yard cable

+80EH0500+S03

BO 5.1

239

237

-X30

236

Siprotec 7UT85

-F21.5
/45.1

238

X30:151

/1 1 .5

B14

X30:153

X2:31
-X223

-X213

E03-W9A

47x1,5 sq mm

31

-X21 3

E03-W9B
47x1,5 sq mm

31

E03-W9A
47x1 ,5 sq mm
+80EH0500+S03

X1:4

X1:31

-X30

243

Yard cable

Acceptance Code:

X30:1 57
/1 1 .6

06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO

TRANSFORMER 80ET0100A

Control voltage and commands

3-Position switch QZ9

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-19

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

19

DN02-S09011-E-XK-1002-19

+E03

Sheets:

58

<1>

<2>

<4>

<3>

<5>

+80EH0500+S03

<>

No. / Text

/1 2.2

Heater Circuit breaker Q0

230 VAC

Heater Disconnector Q1

230 VAC

Heater 3-Position switch QZ2

230 VAC

Heater 3-Position switch QZ9

230 VAC

Heater Earthing switch Q8

230 VAC

X202:44

E03-W1
47x1,5 sq mm

47x1,5 sq mm

-X224

E03-W9A
47x1,5 sq mm

E03-W8

47x1,5 sq mm

E03-W2A
47x1,5 sq mm

-X213

-X21 2

E03-W07

-X211

-X202

X1:1

X1:1

-EB1

-EB2

-EB1

2
-EB1

-EB2

-EB2

-EB1

-Q8

/56.4

-EB2

X1:2

X1:2

E03-W2A
47x1,5 sq mm

E03-W9A
47x1,5 sq mm

X1:2

X1:2
E03-W1
47x1,5 sq mm

E03-W07
47x1,5 sq mm

X07:6
6

-EB3

-QZ9
/54.4

-EB2

-EB1

-QZ2
/52.4

-Q1
/50.4
1

-Q0_1
/46.4

X1:1

X1:1

X07:5

X07:4

X07:3

+80EH0500+E03

E03-W8

47x1,5 sq mm

-X213

B
A

-X224

-X21 2

-X211

-X202

+80EH0500+S03

E
X202:6

/1 2.4

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO

TRANSFORMER 80ET0100A

Heating

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-20

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

20

DN02-S09011-E-XK-1002-20

+E03

Sheets:

58

3
<2>

<1>

<4>

<3>

<5>

<6>

<7>

<8>

L+ 110 DC

X30:2

<>

250

/1 1 .1

-X30

Circuit breaker Q0 off

Status contact

110 VAC

Circuit breaker Q0 on

Status contact

110 VAC

46

Disconnector Q1 off

Status contact

110 VAC

X2:46

Disconnector Q1 on

Status contact

110 VAC

43

Yard cable

No. / Text

3-position switch QZ2

disconnector off

Status contact

110 VAC

3-position switch QZ2

disconnector on

Status contact

110 VAC

X222:46

/22.1

E03-W2A
47x1,5 sq mm

46

E03-W2B
47x1,5 sq mm

-X222

46

46

41
X06:41

E03-W1
47x1,5 sq mm

39

46

X06:39

E03-W06
47x1,5 sq mm

-X21 2

46

-X211

39

-X201

41

+80EH0500+S03

X2:7

X1:46

44

X2:8

X2:9

-X222

E03-W2B

47x1,5 sq mm

-X212

42

44
X1:9
9

E03-W2A

47x1,5 sq mm

41

43

X1:7
41
42
X1:8

X1:9
9

X1:8
8

42
-X211

-BG2

E03-W1

47x1,5 sq mm

40

-X201

+80EH0500+S03

42

E03-W06

47x1,5 sq mm

X06:42
41

112
X06:40
40

-QZ2_2

/53.4

-BG1
44

-BG1
114

-BG1

-QZ2_1
/53.4

43

X1:7
-Q1_1
/51 .4

41

111

-Q0_4
/49.4

113

+80EH0500+E03

X1:46

3-position switch QZ2

earthing switch off

Status contact

110 VAC

3-position switch QZ2

earthing switch on

Status contact

110 VAC

307

306

D5
BI 3.3

D6

305
C14
BI 3.2

BI 3.4

D3

D1

D4

D2

303

304
BI 3.1

C13

-F21.3

/44.1

BI 1 .4

BI 1 .2

D14

D13

D9

BI 1 .3

Siprotec 7UT85

D12

BI 1 .1

D11

-F21.1

/43.1

Siprotec 7UT85

302

D10

300

-X30

301

Yard cable

F21.1:D14

/22.1

L-

X30:51 /1 1 .2

Acceptance Code:

1
06L
05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Supplier

HFO

DETNORSKE

As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Breaker/switch positions
Status to Siprotec

StWe

04L

Drawing Title:

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-21

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

21

DN02-S09011-E-XK-1002-21

+E03

Sheets:

58

<1>

<2>

<3>

<4>

<5>

<8>

<7>

<6>

L+ 110 DC

<>

3-position switch QZ9

earthing switch off

Status contact

110 VAC

46
21
46
A

-X202

3-position switch QZ9

earthing switch on

Status contact

110 VAC

Earthing switch Q8 off

Status contact

110 VAC

Earthing switch Q8 on

Status contact

110 VAC

On-spring unloaded Q0

Fault contact

110 VAC

General lockout SF6 Q0

Fault contact

110 VAC

315

A8

A7
BI 4.3

BI 4.4

A5

BI 4.2

A4

BI 4.1

A3

Siprotec 7UT85

A1

-F21.4

/44.4

B
A2

A6

314

313

312

311

BI 3.8

D11

D10

BI 3.7

D14

D8

D7

BI 3.6

D9

Siprotec 7UT85

BI 3.5

D13

B
-F21.3
/44.1

D12

310

309

308

-X30

22
X07:16

X07:11
7

46
A

-X224

E03-W07

47x1,5 sq mm

Yard cable

3-position switch QZ9

disconnector on

Status contact

110 VAC

-K10

12

14
X1:9

X1:8
7

46

E03-W8
47x1,5 sq mm

-X223

E03-W2B
47x1,5 sq mm

46

-X213

+80EH0500+S03

X07:15

X07:10
81

-Q0_3

/48.1

13

X1 :7

15

10
7

E03-W07
47x1,5 sq mm

E03-W2A
47x1,5 sq mm

3-position switch QZ9

disconnector off

Status contact

110 VAC

-BG16
12

44
X2:9

X2:8

A
B

X1:46

46

11

43

-Q8_1
/57.4

-X202

-BG1

42

44
X1:9

42
X1:8

46

46
46

E03-W8
47x1,5 sq mm

-BG2

-BG1

A
B

X2:46

7
X2:7
41

43

-QZ9_2

/55.4
/55.4

-X224

E03-W2B

47x1,5 sq mm

X1 :46

7
41

-QZ9_1
/55.4

A
B

46

X1:7

+80EH0500+E03

-X223

A
B

E03-W2A
47x1,5 sq mm

1
X202:15

/23.2
46

X222:46

/21 .7

-X213

+80EH0500+S03

No. / Text

E
F21.3:D14

/23.1

F21.1:D1 4
/21 .7

L-

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE

As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO

TRANSFORMER 80ET0100A

Breaker/switch positions

Status to Siprotec

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-22

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

22

DN02-S09011-E-XK-1002-22

Sheets:

58

<1>

<2>

<3>

<4>

<5>

<6>

<7>

L+ 110 DC

<>

40

40

Motor running time

supervision Q0

Fault contact (alarm high)

110 VAC

Loss of SF6 Q0

Fault contact (alarm high)

110 VAC

40

40

E03-W8

47x1,5 sq mm

-X223

X1 :40
B

Yard cable

3-position switch QZ9

crank inserted

Status contact

110 VAC

Earthing switch Q8

crank inserted

Status contact

110 VAC

Yard cable

319

BI 4.8

A14

Siprotec 7UT85

B2

-F21.4

/44.4

A13

A12

F21.3:D1 4
/22.7

F21.4:A8

/24.1

L-

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

StWe

04L

As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO

TRANSFORMER 80ET0100A

Signals to Siprotec

Signals from CB Q0

DETNORSKE

Issue

B1

A10

A9

BI 4.7

BI 4.6

A11

Siprotec 7UT85

BI 4.5

A
B

B
-F21.4
/44.4

318

317

316

-X30

Crank inserted

common alarm (alarm high)


110 VAC

D
-X30

14
41

-X224

41

-X212

41

-X211

41

41

11

10

12

3-position switch QZ2

crank inserted

Status contact

110 VAC

E03-W8

47x1,5 sq mm

+80EH0500+S03

-X201

X1:41

14
41

E03-W9A
47x1,5 sq mm

Disconnector Q1

crank inserted

Status contact

110 VAC

-BG22

X1 :41

14
E03-W2A
47x1,5 sq mm

41

41

11

10

12

E03-W1
47x1,5 sq mm

4
13

13

-Q8
/56.4

-BG23

X1 :41

E03-W06
47x1,5 sq mm

Spring charge motor MCB Q0

(MCB inside of breaker)

Status contact (alarm high)

110 VAC

X1:40

X1:40

-QZ9
/54.4

-BG23

X1:41

-X224

E03-W9A
47x1,5 sq mm

13

13

-QZ2
/52.4

14

11
X06:11

X06:1 0

22
X06:1 2

40

40

E03-W2A
47x1,5 sq mm

-BG23

25

-BP1

-X223

X1 :40
-K67

-F1

-Q1
/50.4

13
12

21

-Q0_2
/47.4

26
28

+80EH0500+E03

E03-W1
47x1,5 sq mm

X06:1 4

E03-W06
47x1,5 sq mm

A
B

14

-X21 2

40

-X211

40

-X201

X224:40

/24.1

X202:1 5
14

/22.7

+80EH0500+S03

No. / Text

Signature:

David Stone

28/05/15
=

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-23

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

23

DN02-S09011-E-XK-1002-23

Sheets:

58

<2>

<1>

<3>

<4>

<5>

<6>

<7>

<10>

<9>

<8>

L+ 110 DC

<>

No. / Text

+80EH0500+S03

X224:40

/23.6

-X99

14

SF6 Signals from BP1

GC01 (Q1 chamber)

SF6-loss warning

110 VAC

SF6 Signals from BP1

GC01 (Q1 Chamber)

SF6-loss critical (trip)

110 VAC

SF6 Signals from BP1

GC02 (QZ2 Chamber)

SF6-loss warning

110 VAC

E03-W95

7x1 ,5 sq mm

A
B

E03-W94

7x1,5 sq mm

X99:1 4

13

11

E03-W93
7x1,5 sq mm

10

E03-W92

7x1 ,5 sq mm

E03-W91

7x1,5 sq mm

/25.3

+80EH0500+E03

23
22

13
12

SF6 Signals from BP1

GC02 (QZ2 Chamber)

SF6-loss critical (trip)

110 VAC

SF6 Signals from BP1

GC03 (QZ9, Q8, Z1 Chamber)

SF6-loss warning

110 VAC

4
21

11

E03-W95

7x1,5 sq mm

SF6 Signals from BP1

GC03 (QZ9, Q8, Z1 Chamber)

SF6-loss critical (trip)

110 VAC

SF6 Signals from BP1

GC04 (T5 Chamber)

SF6-loss warning

110 VAC

SF6 Signals from BP1

GC04 (T5 Chamber)

SF6-loss critical (trip)

110 VAC

SF6 Signals from BP1

GC05 (F1 Chamber)

SF6-loss warning

110 VAC

35

25

24

34

33

32

22

21

31

23

+80EH0500+S03

-X99

325

B
D6

D5
BI 4.1 3

BI 4.1 4

10
SF6 Signals from BP1

GC05 (F1 Chamber)

SF6-loss critical (trip)

110 VAC

D8

B6

B7

BI 4.1 2

D7

BI 4.11

324

323

BI 4.1 0

-X30

B8

B3
BI 4.9

B10

B5

Siprotec 7UT85

-F21.4

/44.4

-X30

B4

322

B9

320

-X30

321

Yard cable

F21.4:A8

/23.6

Acceptance Code:

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE

As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Description

Made by

Date

Chc. by

Appr. by

SMOE

Tag no.

Wood Group

Mustang
Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Signals to Siprotec
Pressure alarm/trip from GIS chambers

StWe

04L

Issue

F21.4:B6

/25.1

L-

06L

-BP5

P
21

11
E03-W94

7x1,5 sq mm

-BP5

21

23
22

13
12

23
22

-BP4

-BP4

11
1

E03-W93

7x1,5 sq mm

+GC05

21

21

-BP3

E03-W92

7x1,5 sq mm

13
12

23
22

-BP3

-BP2

11

-BP2

E03-W91

7x1,5 sq mm

13
12

-BP1

+GC04

+GC03

11

-BP1

23
22

+GC02

13
12

+GC01

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-24

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

24

DN02-S09011-E-XK-1002-24

Sheets:

58

2
<1>

<2>

<4>

<3>

<5>

L+ 110 DC

X30:3

/1 1 .1

X30:4

X30:5

/1 1 .1

<>

/1 1 .1

No. / Text

+80EH0500+S03

/24.7

X99:1 4

X1:7

9
13

BN

14

X1:8

10 14

5
13

BK

X1 :3
BK
BN
X1:4

Line voltage transformer

connected (Core 1)

Common alarm VT MCB and


VT disconnector

A
5

Line voltage transformer

connected (Core 2)

Common alarm VT MCB and

VT disconnector

-X261

Yard cable

-X501

7
13

-F721

/06.5

327

326

Yard cable

14

-X30

14

3
13

Common MCB alarm critical

Trip coil 1 or 2 MCB fault

+80EH0500+S03

-X501

B
B

A1

A2

A7

BI 5.2

BI 5.1

BI 5.3

A4

A5

A3

Siprotec 7UT85

-F722

/06.6
-X501

14
D10

BI 4.16

-X501

-F21.5

/45.1

Common MCB alarm

+80EH0500+S03

-BG2

-X30

-X501

E03-W61

25x1,5 sq mm

-F711
/06.2

D12

D11

-T61
/07.3

4
4

1 3 14

-X501

-F230.1

/03.7

D9

Siprotec 7UT85

BI 4.1 5

-F230.2
/04.7

-F21.4
/44.4

13

13 14
1 3 14

-X261

13 14

-X501

-F712
/06.3

-F11
/04.5

-U4
/03.4

+80EH0500+E03

+80EH0500+S03

+80EH0500+S03

13 14

-U3

/03.3
13 14

14

13 14

13 14
13 14
13 14
13 14

-F10
/04.4

Control voltage failure


110 VDC bus and voltage

converter 230 VAC/110 VDC

E03-W61
25x1,5 sq mm

-X501

E03-W61
25x1,5 sq mm

-BG1

-F9

/04.3

-U2

/03.2

14

-T61
/07.3

-F8
/04.2

-U1
/03.1

+80EH0500+E03

-F5

/03.4

-F7
/04.1

-F2

/03.3

E03-W61
25x1,5 sq mm

13 14

-F6

/03.6

-F1
/03.1

-F4

/03.3

13 14

13 14

-B1
/03.5

-X261

-F3

/03.1
13 14

11

13

-X261

F21.4:B6

/24.5

LAcceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Appr. by

Wood Group

Installation: Ivar Aasen Field

Mustang
Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Signals to Siprotec

Alarms and Cable VT MCB failure

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-25

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

25

DN02-S09011-E-XK-1002-25

+E03

Sheets:

58

<2>

<1>

<3>

<4>

<5>

<6>

<7>

L+ 110 DC

X30:6

X30:7

/1 1 .1

X30:8

/1 1 .1

X30:19
/1 1 .1

/1 1 .1

X30:20

<>

/1 1 .1

-X31

20

18

-X31

Control power to Siprotec

7UT85

110 VDC

Busbar A voltage MCB F158

fault contact

110 VDC

Busbar B voltage MCB F1 59

fault contact

110 VDC

Arc detection trip Status

Close Circuit breaker from

ESS A generator control

panel 82JC0001

Close Circuit breaker from

generator control panel

Spare

Spare BI

Yard cable

+82JC0001

14

13

No. / Text

SPARE

13

-X31

81

B2

B1

BI 5.8

BI 5.9

A14

A13

B3

BI 5.7

BI 5.6

A12

BI 5.5

-X30

A10

A9

A8
BI 5.4

A11

A6

Siprotec 7UT85

-F21.5

/45.1

B2

Siprotec 7UT85

B1

XR4:8

80

-X31

19

/1 4.7

-F21.2
/43.4

14

14

21

-F159
/05.3

-F158
/05.5

B5

13

Yard cable

F21.5:A12

/27.1

X30:108

/1 1 .4

L-

X30:52 /1 1 .2

06L
As Built
05L
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

StWe

04L
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I
Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO

TRANSFORMER 80ET0100A

Signals to Siprotec

Bus bar VT MCB failure and Internal trip signals

DETNORSKE

Issue
Description

Acceptance Code:

X30:53 /1 1 .2

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-26

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

26

DN02-S09011-E-XK-1002-26

+E03

Sheets:

58

<1>

<2>

<3>

<4>

<6>

<5>

<7>

L+ 110 DC

X30:10

X30:11

/1 1 .1

X30:12

/1 1 .1

X30:13

/1 1 .1

/1 1 .1

X30:18

<>

/1 1 .1

ESD Trip. Status and

trip signal to IED

110 VDC

(Disabled, spare)

PSD Trip. Status and

trip signal to IED

110 VDC

(Disabled, spare)

Temperatur High-High Trip

status and trip signal

to IED

110 VDC

11
7

Overflux trip

status and trip signal

to IED

110 VDC

Spare BI

Spare BI

85

84

D12

D11

BI 5.1 6

D10

D8

B8

B7

BI 5.1 5

BI 5.1 4

D9

BI 5.1 3

D7

BI 5.1 2

D6

D5

B10

B9

B4

BI 5.1 1

B6

Siprotec 7UT85

B
A

BI 5.1 0

Bucholz Trip

status and trip signal

to IED

110 VDC

11
7

3
11
7

-X30

-F21 .5

/45.1

-K07

/29.6

-K02.2

/28.5

-K01.2
/28.3

-K06
/29.4
3

-K05
/29.2
3

-K02.1
/28.5

11
7

11
7

11
7

11
7

-K01.1
/28.3

No. / Text

F21.5:A12
/26.7

F21.5:D10

/30.1

LAcceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EC0503

1 10 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO

TRANSFORMER 80ET0100A

Signals to siprotec

External trip signals

StWe

04L

Tag no.

Signature:

5
28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-27

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

27

DN02-S09011-E-XK-1002-27

Sheets:

58

<1>

<2>

<>

No. / Text

+SAS

Yard cable

ESD trip from SAS

24 VDC

(Disabled, spare)

PSD trip from SAS

24 VDC

(Disabled, spare)

Yard cable

-X24

-X24

-K02.2

/.5

-K02.1
/.5

-K01.2
/.3

-K01.1
/.3

-K01.1

-K01.2
3

7
/27.1 11
8
/1 4.2 12
9
13
10
14

4
5
6

7
/27.1 11
8
/1 4.2 12
9
13
10
14

-K02.1
3

7
/27.2 11
8
/1 4.3 12
9
13
10
14

4
5
6

-K02.2

7
/27.2 11

8
/1 4.3 12

9
13

10
14

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Trip signals from SAS


ESD and PSD

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-28

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

28

DN02-S09011-E-XK-1002-28

+E03

Sheets:

58

<1>

<2>

<3>

L+ 110 DC

X30:1 4

X30:15

/1 1 .1

X30:9

/1 1 .1

<>

/1 1 .1

Yard cable

7
3

Yard cable

-X31

-X31

Yard cable

-X31

-13X2

B
A

Yard cable

Overflux trip from

Transformer 80ET01 00A

110 VDC

9
-1 1 X2

L-

-K07

/.6

-K06
7
/27.4 11
8
/1 4.5 12
9
/1 4.5 13
10
14

3
4
5
6

X30:54 /1 1 .2

-K05
7
/27.3 11
8
/1 4.4 12
9
/1 4.4 13
10
14

-K06
/.4

-K05
/.2

3
4
5
6

-K07

7
3

/27.5 11

8
4

/1 4.5 12

9
5

/1 4.5 13

10
6

14

X30:58 /1 1 .2

X30:55 /1 1 .2

Acceptance Code:

1
06L

-13T1

-4X1

-11T1
19 CO

-R1

Buchholz trip from

Transformer 80ET0100A

110 VDC

NC

-13X2

18

+80ET0100A

-11X2

Temperatur High-High trip

from Transformer 80ET0100A

110 VDC

Yard cable

+80ET0100A
-4X1

Yard cable

+80ET0100A

-X31

-X31

-X31

No. / Text

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Trip signals from Transformer


.

StWe

04L

Tag no.

Signature:

David Stone

28/05/15
=

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-29

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

29

DN02-S09011-E-XK-1002-29

Sheets:

58

2
<1>

3
<3>

<2>

<4>

<6>

<5>

<3>

<7>

<8>

L+ 110 DC

<>

X30:16
/1 1 .1

A
7

-X31

No. / Text

Disconnector switch Q1D Open

from

11 kV Incomer 80EH011A+03

110 VDC

Earth switch Q1E closed from

11 kV Incomer 80EH011A+03

110 VDC

Intertrip from 1 1 kV SWBD

Incomer 80EH011A+03

110 VDC

14

19

18

17

-X32

B
A

C14

C12

C8

BO 5.5

BO 5.6

Circuit breaker Closed and

connected from

11 kV Incomer 80EH011A+03

110 VDC

CB closed and connected to

11 kV Incomer 80EH011A+03

(Q1D or QZ2D), Q0 and QZ9D

Closed)

110 VDC

-K08

/.4

Earth switch Q8 open to

11 kV Incomer 80EH011A+03

110 VDC

Intertrip to 1 1 kV

Incomer 80EH011A+03

110 VDC

Disconnector QZ9D open to

11 kV Incomer 80EH011A+03

110 VDC

29

26

24

25

23

A14

A12

Yard cable

BI 6.8

A13

BI 6.7

=80EH0011A

+K03

B2

B1

A9

BI 6.6

-X32

BI 6.5

A11

Siprotec 7UT85

-F21.6

/45.4

A10

-K08

7
/1 4.6 11

8
4

/1 4.6 1 2

9
5

13

10
14

17

-X31

16

15

12

14

13

11

-X31

10

Yard cable

BO 5.8

BO 5.7

C13

C11

C7

15

-X32

C6

-F21.5

/45.1

C5

=80EH0011A

+K03

Siprotec 7UT85

Yard cable

E
F21.5:D10

/27.7

L-

X30:57 /1 1 .2

Acceptance Code:

1
06L
05L

As Built
As Built

05.05.1 5
DSF
1 7.03.1 5
EsFr

EsFr
HFO

Supplier

HFO

DETNORSKE

As Built

1 4.1 1 .1 4
EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4
EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Trip signals from/to 1 1 kV SWBD incomer


.

StWe

04L

Drawing Title:

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-30

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

30

DN02-S09011-E-XK-1002-30

+E03

Sheets:

58

<1>

<2>

<3>

L+ 110 DC

<>

Circuit breaker open

to ESS A generator

control panel 82JC0001

24 VDC

Circuit breaker closed

to ESS A generator
control panel 82JC0001

24 VDC

133

131

B12

Voltage transformer T5

online to ESS A generator

control panel 82JC0001

24 VDC

132

134

-BG1

44
B

41

42

46

39
39

-X202

40

+80EH0500+S03

40

E03-W07

47x1,5 sq mm

X07:42

X07:40

BO 6.1

B11

Siprotec 7UT85

-F21.6

/45.4

-Q0_4
/49.4

1
X07:41

X07:39

+80EH0500+E03

No. / Text

342

12

-X24

10

-X24

341

11

-X30

340

339

Yard cable

Yard cable

+82JC0001

-X

LAcceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Signals to Generator Control panel


.

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-31

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

31

DN02-S09011-E-XK-1002-31

Sheets:

58

<1>

<2>

<3>

<4>

<5>

<6>

<7>

328

<>
-X30

110 VDC L+

From Bus-Coupler E01

Circuit breaker Q0 off

To Bus-Coupler E01

Status contact

110 VAC

Circuit breaker Q0 on

To Bus-Coupler E01

Status contact

110 VAC

12

10

12

10

E03-W1

47x1,5 sq mm

-X212

12

45

43

12

E03-W06
47x1,5 sq mm

-X211

10

10

43

-X201

45

+80EH0500+S03

E03-W2A

47x1,5 sq mm

+80EH0500+E03

X1:10

X1:12
53

54

52

54

-BG1

52

122

51

X1:12

X1:10

53

-QZ2_1

/53.4

-BG1
124

-BG1

51

-Q1_1

/51 .4

.4

123

X06:43

X06:45

121

-Q0_4
/49.4

X1:11

X1 :1 3
13

X1:13
13

E03-W1

47x1,5 sq mm

11

X1:11

X06:46
46

11

X06:44
44

E03-W06
47x1,5 sq mm

E03-W2A
47x1,5 sq mm

+80EH0500+S03

-X21 2

13

11

-X211

13

11

44

46

-X201

No. / Text

3-position switch QZ1

disconnector off

To Bus-Coupler E01

Status contact

110 VAC

3-position switch QZ1

disconnector on

To Bus-Coupler E01

Status contact

110 VAC

3-position switch QZ2

disconnector off

To Bus-Coupler E01

Status contact

110 VAC

3-position switch QZ2

disconnector on

To Bus-Coupler E01

Status contact

1 1 0 VAC

A
B

334

333

332

331

-X30

330

329

Yard cable

Inter connection terminals

B
A

14

B
A

13

12

11

10

-XR3

Details shown in document:

DN02-S09011-E-XK-1006-01

Acceptance Code:

1
Supplier

06L

As Built

05.05.1 5
DSF

EsFr

HFO

05L

As Built

1 7.03.1 5
EsFr

HFO

StWe

As Built

1 4.1 1 .1 4
EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4
EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503
110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO

TRANSFORMER 80ET0100A

Scale
Breaker/Switch status to Bus Bar differential relay
Area:
.

NA
M120

DETNORSKE

04L

Drawing Title:

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Siemens Dwg. No.:

51PO-04193.210-K-102-32

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

32

DN02-S09011-E-XK-1002-32

Sheets:

58

<1>

<3>

<2>

<4>

<6>

<5>

<>

Preasure measurement

to SAS

GC00 (CB, T1)

6,5 - 20 mA

Preasure measurement

to SAS

GC01 (Q1)

6,5 - 20 mA

Preasure measurement

to SAS
GC02 (QZ2)

6,5 - 20 mA

Preasure measurement

to SAS

GC03 (QZ9, Q8, Z1)

6,5 - 20 mA

Preasure measurement

to SAS

GC04 (T5)
6,5 - 20 mA

B
A

12

11

10

+SAS

B
A

Yard Cable

C
6

Preasure measurement

to SAS

GC05 (F1)

6,5 - 20 mA

bn

bk

bn

A
B

E03-W95S

2x0,35 sq mm

6,5-20 mA

+
+GC04
-BP4.

62

61

60

E03-W94S
2x0,35 sq mm

6,5-20 mA

6,5-20 mA

+GC03
-BP3.

bk

bn

E03-W93S
2x0,35 sq mm

59

bk

bn

bk

+
+GC02
-BP2.

A
B

6,5-20 mA

58

57

56

55

54
bn

A
B

E03-W92S
2x0,35 sq mm

+
+GC01
-BP1.

A
B

6,5-20 mA

+
+GC00
-BP1

A
B

E03-W91S
2x0,35 sq mm

6,5-20 mA

+80EH0500+E03

A
B

bn

E03-Q0-WG1S
2x0,35 sq mm

53

bk

bk

51

52

+80EH0500+S03

-X99

No. / Text

+GC05

-BP5.

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Condition monitoring
Gas density sensors

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-33

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

33

DN02-S09011-E-XK-1002-33

Sheets:

58

<1>

<>

No. / Text

Capacative voltage

Indicator

L3

L1

L2

Sensors in cable terminations Female part

L3

L1

L2

-A51

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Capacitive voltage indicators


.

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-34

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

34

DN02-S09011-E-XK-1002-34

+E03

Sheets:

58

/04.5

F1 1:3

MI

CPU

MC1

Power distrubution

to Trafoguard.

Reinhausen TrafoGuard

Power and communication

modules

CAN-H

CAN-GND

CAN-L

CAN-SHLD

CPU-X9:04

CPU-X9:01

CPU-X9:02

CPU-X9:03

TxD

RxD

X30:1 77

/39.7

CAN-BUS

MC1-X1:02

FIBER OPTIC-OUTPUT

VISU

1310nm ST

MC1-X1:01

X30:176

/38.6

SID- CARD

VISU

ETHERNET

2RJ45

IEC 61850

X30:1 75

/40.2

1RJ45

Power supply

X30:174

/37.7

SU-X1:02

Load current

X30:173

/36.6

5A
1A
0,2A
0

Load voltage

X30:172

/.6

X30:179

/36.3

-XT10

-R
B

X30:161

/.1

X32:1
/08.3

120 ohm

X30:1 69 B

SID

No. / Text

X30:171
/.2

X30:1 63

/.1

Canbus cable

X30:168 B

MI:06
MI:09
MI:10
MI:05

X30:167 B

X30:171

/.4

MI:02

X30:166 B

MI:01

175
176
177
178
179

X30:165 B

SU

/36.3

165

/38.5

166

/39.4

1 67

/38.4

168

/40.2

X30:164 B

1 69

170
171
172
173
174

160
161
162
163

X30:162 B

X30:163 B

/.5

/37.7

-X30

164

X30:161 B

/.4

/36.5

<>

-F22_1

-X30

/04.6

SU-X1:01

F1 1:1

<2>

<1>

X30:172

/.2

F21.1:B1

/08.3

Yard Cable

120 ohm

-F22:X9

A
B

A
B

A
B

04

01

02

03

-XT5

512

-R
511

=80EH0011A

+K03

+80EC0504

Acceptance Code:

1
06L
05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Supplier

HFO

DETNORSKE

As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Appr. by

Tag no.

Wood Group

Mustang
Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Reinhausen Transformer Guard


Power and Communication modules

StWe

04L

Drawing Title:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-35

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

35

DN02-S09011-E-XK-1002-35

Sheets:

58

<1>

<>

No. / Text

Voltage regulator raise

Voltage regulator lower

Reinhausen TrafoGuard

IO module IO

Auto

Tap ch. in pr OLTC

Motor protected. OLTC

Auto

Manual

AVR raise

AVR lower

Follower

Master

Parallel op. groupe 2

Parallel op. groupe 1

Status

Function monitoring

-F22_2

Parallel operation error

Motor protect OLTC active

IO

IO-X1:10

IO-X1 :08

IO-X1:09

IO-X1:05
73
13 74

IO-X1:04
63
64

IO-X1:07
53

IO-X1:06
43

33

IO-X1:30

IO-X1:28
23

13

IO-X1:29

IO-X1:15

IO-X1:12

IO-X1:11

IO-X1:13

IO-X1:14

IO-X1:27

IO-X1:17

IO-X1:16

IO-X1:34

IO-X1 :33

IO-X1:32

IO-X1:31

IO-X1:20

IO-X1 :1 8

IO-X1:19

IO-X1:24

IO-X1 :23

IO-X1:26

IO-X1:25

IO-X1:22

IO-X1:21

IO-X1:03

IO-X1:01

IO-X1:02

B
A

11 54

10 44

34
A

B
A

B
A

12

-X32

24

14

-K1 0

/40.1

Yard Cable

41

54

69

-X1

B
BO 6.5

10

11

-X1

17

+80EC0101A

-X1

20 53

-K20

18 42

-Q1
C6

Siprotec 7UT85

C5

-F21.6

/45.4

19

X30:1 73

/35.2

B
A

14

-X32

83

A
B

A
B

-K10

/40.1

X30:179

/35.2

84

X30:169

/35.1

15

Yard Cable

X30:162
/35.1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Reinhausen Transformer Guard


I/O mudule

StWe

04L

Drawing Title:

Supplier

HFO

Acceptance Code:

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-36

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

36

DN02-S09011-E-XK-1002-36

Sheets:

58

<1>

<>

No. / Text

Reinhausen TrafoGuard

IO module UC1

BCD 1

BCD 2

BCD 4

BCD 8

BCD 10

BCD 20

BCD-

BCD+

Cooling stage 1 on

Spare

trf. overpressure alarm

Cooling stage 3 error

Cooling stage 3 on

Cooling stage 2 on

Cooling stage 1 error

Cooling stage 1 on

Maximum cooling

Cooling monitoring

Cooling stage 2 error

-F22_3

Independent

UC1

UC1-X1:34

UC1-X1:33

UC1-X1:32

UC1-X1:31

UC1-X1:30

UC1-X1:29

UC1-X1:17

UC1-X1:16

UC1-X1:15

UC1-X1:14

UC1-X1:13

UC1-X1:12

UC1-X1:11

UC1-X1:26

UC1-X1:27

UC1-X1:24

UC1-X1:25

UC1-X1:22

UC1-X1:23

UC1-X1:20

UC1-X1:21

UC1-X1:18

UC1-X1:19

UC1-X1:09

UC1-X1:10

UC1-X1:07

UC1-X1:08

UC1-X1:05

UC1-X1:06

UC1-X1:03

UC1-X1:04

UC1-X1:01

UC1-X1:02

/35.1

93

83

73

63

53

43

33

23

13

X30:164

94

84

74
B

22

64
B

21

20

24

54

44

34
B

23

19

18

16

-X32

17

14

24

-K11

/40.2

X30:174

/35.2

Yard Cable

-S61M

=80EC0101A

Acceptance Code:

1
06L
05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Supplier

HFO

DETNORSKE

As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Appr. by

Tag no.

Wood Group

Mustang
Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Reinhausen Transformer Guard


IO/module

StWe

04L

Drawing Title:

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-37

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

37

DN02-S09011-E-XK-1002-37

Sheets:

58

<1>

<>

No. / Text

Reinhausen TrafoGuard

IO module UC2

Spare

Spare

Spare

Spare

Blocking operation

Spare

Spare

Buchholtz Alarm

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

-F22_4

Signal heat circuit MCB

UC2

UC2-X1:34

UC2-X1:33

UC2-X1:32

UC2-X1:31

33

UC2-X1:30

UC2-X1:29

UC2-X1:17

23

13

UC2-X1:16

UC2-X1:15

UC2-X1:14

UC2-X1:13

UC2-X1:12

UC2-X1:11

UC2-X1:26

UC2-X1:27

UC2-X1:24

UC2-X1:25

UC2-X1:22

UC2-X1:23

UC2-X1:20

UC2-X1:21

UC2-X1:18

UC2-X1:19

UC2-X1:09

UC2-X1:10

UC2-X1:07

UC2-X1:08

UC2-X1:05

UC2-X1:06

UC2-X1:03

UC2-X1:04

UC2-X1:01

UC2-X1:02

29

34

B
A

34

A
31

33 24

-X32

32 14

-K1 2

/40.2

B
A

Yard Cable

-X1

21
-K10

-X1

B
-F1 3

256 22

12

-11T1

-11X2

-X1

10

144

+80EC0101A

21

169 22

-11X2

+80EC0100A

255

X30:176

/35.2

-X1

30

-X32

35

-X32

43

A
B

36

Yard Cable

A
B

44

-K1 2

/40.2

X30:1 66
/35.1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Acceptance Code:

1
Tag no.

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Reinhausen Transformer Guard


IO/module

StWe

04L

X30:1 68
/35.1

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-38

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

38

DN02-S09011-E-XK-1002-38

+E03

Sheets:

58

<1>

TRF Overpressure releif


common tank

No. / Text

Reinhausen TrafoGuard

IO module UC3

Spare

Spare

TRF topoil temp high

1
TRF topoil temp low

High oil level main

trf. main oilflow

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Air purging failure

Low oil level common tank

UC3

-F23_5

High oil level common tank

<>

UC3-X1:34

UC3-X1:33

UC3-X1:32

UC3-X1:31
B

43

42

UC3-X1:30

UC3-X1:29

UC3-X1:17
A

44

40

41

UC3-X1:16

UC3-X1:15
B

39

37

-X32

38

UC3-X1:14

UC3-X1:13

UC3-X1:12

UC3-X1:11

UC3-X1:26

UC3-X1:27

UC3-X1:24

UC3-X1:25

UC3-X1:22

UC3-X1:23

UC3-X1:20

UC3-X1:21

UC3-X1:18

UC3-X1:19

UC3-X1:09

UC3-X1:10

UC3-X1:07

UC3-X1:08

UC3-X1:05

UC3-X1:06

UC3-X1:03

UC3-X1:04

UC3-X1:01

UC3-X1:02

X30:177

/35.2

Yard Cable

21

24

-4X1

-4U1

-4X1

-4X1

22

-15X2

25

-1 6X2

-4U1

-4X1

21

-15T1
22

9
-1 1 X2

-5K1

12 12

-11T2

-15X2

-11T2

-1 1 X2

-1 6X2

10

-1 1 X2

-11X2

10

+80EC0100A

50

49

48

47

45

-X32

46

Yard Cable

X30:167
/35.1
06L
05L

As Built
As Built

05.05.1 5
DSF
1 7.03.1 5
EsFr

EsFr
HFO

DETNORSKE
As Built

1 4.1 1 .1 4
EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4
EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Reinhausen Transformer Guard


IO/module

StWe

04L

1
Drawing Title:

Supplier

HFO

Acceptance Code:

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-39

System:

DWG Size Drawing No.:

80

A3

+E03

Rev:

DN02-S09011-E-XK-1002-39

Sheet:

06L 39
8

Sheets:

58

<2>

<1>

<>

03

34
44
54
64
74
84
94
04

34

44

54

64

74

84

94

4-20 mA input SPARE

24

4-20 mA input SPARE

23
/37.6

33
/37.6

43
/37.6
53
/37.6
63
/37.6

73
/37.6

83
/37.7
93
/37.7

03

4-20 mA input SPARE

24

AD8-1

-F22_6

4-20 mA input SPARE

14

4-20 mA input SPARE

A1

-K12

/.3

A2

A1

-K11
/.3

A2

A2

-K10
/.3

A1

X30:165

13

/37.6

4-20 mA input SPARE

X30:1 75

/35.1

-K11
14

4-20 mA input SPARE

13

/36.5

23

/36.6

33

/36.6

43

/36.6

53

/36.6

63

/36.6

73

/36.6

83

/36.5

93

Top oil temp trf.

-K10
/35.2

No. / Text

04

D
A

D
A

- +

D
A

- +

D
A

- +

D
A

- +

Relays that disconnects all


communication towards OLTC

if purge controller fails.

Reinhausen TrafoGuard

IO module AD8-1

A
- +

- +

A
- +

-16X2

64

73

74

83

84

93

94

03

AD8-1X1:16

AD8-1X1:15

AD8-1X1:14

AD8-1X1:13

AD8-1X1:12

AD8-1X1:11

AD8-1X1:10

AD8-1X1:09

AD8-1X1:08

AD8-1X1:07

AD8-1X1:06

AD8-1X1:05

AD8-1X1:04

54

AD8-1X1:03

44

-X32

26

34

63

AD8-1X1:02

24

04

13

=80EC0100A

14

AD8-1X1:01

B
A

Yard Cable

13

/38.5

23

/38.5

33

/38.6

43

/38.5

53

25

27

-X32

28

-K12

4-20 mA

14

-5K1

Yard Cable

12

-4X1

A
B

13

=80EC0100A

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Reinhausen Transformer Guard

IO module

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-40

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

40

DN02-S09011-E-XK-1002-40

+E03

Sheets:

58

2
<1>

3
<2>

5
<4>

<3>

6
<5>

<6>

<>

-F23:BC63

-F23:BC63

-F23:BC77

-F23:BC77

-F23:BC7

Fiber optical arc detection

sensor

Q1 chamber

Fiber optical arc detection

sensor

QZ2 chamber

Fiber optical arc detection

sensor
QZ9, Q8, Z1 chamber

Fiber optical arc detection

sensor

T5 chamber

Fiber optical arc detection

sensor

F1 chamber

Fiber optical arc detection

sensor

Q0 chamber

Fiber optical wire

Fiber optical wire

Fiber optical wire

Fiber optical wire

Fiber optical wire

+80EC0501

-F23:BC63

No. / Text

Fiber optical wire

+80EH0500+E03

+GC01
-F10

+GC02
-F10

+GC03
-F10

+GC04
-F10

+GC05
-F10

+GC00

-F10

All fiber optical wires

are directly connected

to the arc detection unit in

cublicle 80EC0501

(bus tie LVCC)

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Arc detection sensors


.

StWe

04L

Tag no.

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-41

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

41

DN02-S09011-E-XK-1002-41

Sheets:

58

<1>

<>

No. / Text

Voltage/current measurement

PAC 3200 multimeter

/09.2

XT1:131

B
/09.2

XT1:132

/09.2

/06.5

XT1:121

XT5:12

/09.2

/06.5

XT1:122

XT5:11
/09.3

/1 1 .2

/06.5

XT1:111

X30:56

XT5:10

/09.2

/1 1 .1

/06.5

XT1:112

X30:17

N/-

L/+

X2:N

X2:V3

X2:V2

X2:V1

X1 :IL3 i

X1:IL3 k

X1 :IL2 i

X1:IL2 k

-P02

X1 :IL1 i

X1 :IL1 k

XT5:9

DC:110-340 V

AC:95-240 V

PAC 3200

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Voltage/current measurement unit (PAC 3200)


.

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-42

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

42

DN02-S09011-E-XK-1002-42

Sheets:

58

<1>

IO203

/09.4

<>

No. / Text

Siprotec 5 7UT85

module 1 (IO202)

Siprotec 5 7UT85

module 2 (PS201)

-F21.2
A1

I1

D1

BO 1 .1

A2

/09.4

A3

/09.4

A4

/09.4

A5

/09.4

A6

/09.5

A7

/09.5

A8

/08.3

PS201

-F21.1
/09.4

6
<2>

B1

/08.3

B2

/08.3

B3

/08.3

B4

/08.3

B5

/08.3

B6

/08.5

B7

/08.5

B8

/21 .2

D9

/21 .2

D11

/21 .2

D13

/21 .3

D10

/21 .3

D12

/21 .4

D14

F
BO 1.2

I2

BO 1.3

I3

Power
Supply

D2

/1 3.5

D3

/1 3.6

D4

/1 3.6

/26.1

B1

D5

/1 3.6

/26.1

B2

D6

/1 3.6

Optical IEC61 850

communication port

=
+

D-sub 9 Time

synchronization

B12

D8

BO 2.1

B14

BI 2.2

B13

BI 2.3

B4

BI 2.1

D7

BO 1.4

I4

/1 3.5

B3

B6

I5

B8

BO 2.2

B11

B5

B7

I6

B9

Life contact

B10

I7

I8

BI 1.1

BI 1.3

BI 1.2

BI 1.4

F : Fast Switch

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

1 1 0 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Overview diagram
Siprotec module 1 and 2

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-43

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

43

DN02-S09011-E-XK-1002-43

+E03

Sheets:

58

<1>

IO211

A1
A2

/06.2

A3

/22.5

U1

U2

A5

/06.2

A6

/05.5

A7

/05.5

A8

U3

U4

/05.3

A11

/05.3

A12

A13

U6

U7

C3

U8

C4

C13

/21 .5

C14

/21 .5

D2

1)

1)

BI 3.1

BI 3.2

1)

/21 .6

D3

/21 .6

D5

/21 .6

D4

/21 .6

D6

/22.2

D7

1)

BI 3.4

1)

/22.2

D9

/22.2

D8

/22.2

D10

/22.3

D11

/22.3

D13

/22.4

D12

/22.4

D14

BI 3.3

1)

BI 3.5

BI 3.6

1)

BI 3.7
1)

BI 3.8

A4

/22.6

A5

/22.6

A7

1)

BI 4.1

BO 4.1

<>

No. / Text

Siprotec 5 7UT85

module 3 (IO211)

Siprotec 5 7UT85

module 4 (IO207)

1 )

BI 4.2

BO 4.2

BI 4.3

BO 4.3

B12 /1 6.5
B11 /1 6.5
B13 /1 6.5

1)

1)

C2

/1 7.4

C1

/1 7.4

C4

/1 7.4

A6

/22.6

A8

C3

/1 7.4

A9

C6

/1 7.5

C5

/1 7.5

C8

/1 7.6

C7

/1 7.6

BI 4.4

1 )

/23.2

A11

/23.2

A10

A12

1 )

BI 4.5

BI 4.6

BO 4.4

BO 4.5

BO 4.6

1 )

A13

BI 4.7

BO 4.7

C11 /1 8.5

1)

A14

/23.6

B2

/24.1

B3

/24.1

B5

/24.2

B4

/24.2

B6

/24.3

B7

/24.3

B9

1 )

1 )

BI 4.8

C12 /1 8.5

B1

/23.6

C14 /1 8.5

BO 4.8

C13 /1 8.5

BI 4.9

BI 4.10

1)

BI 4.11

1 )

/24.3

B8

/24.3

B10

/24.4

D5

/24.4

D7

/24.4

D6

/24.4

D8

/25.1

D9

/25.1

D11

/25.2

D10

/25.2

D12

1 )

1 )

BI 4.12

BI 4.13

BI 4.14

1 )

BI 4.15

1 )

BI 4.16

1) USE THESE TERMINALS TO


ROOT THE BINARY INPUTS

1) USE THESE TERMINALS TO

ROOT THE BINARY INPUTS

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Overview diagram
Siprotec module 3 and 4

StWe

04L

B14 /1 6.5

/22.6

/23.3

C2

D1

A2

/23.3

C1

/21 .5

/22.5

/23.2

A14

/21 .5

A3

/23.2
U5

A1

/22.5
/22.5

A4

/06.2

-F21.4

/06.2
/06.2

IO207

-F21 .3
/06.2

6
<2>

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-44

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

44

DN02-S09011-E-XK-1002-44

+E03

Sheets:

58

<1>

-F21.5
/25.3

A1
A3

/25.5

A2
A4

/25.7

A5

/25.7

A7

/26.3

A6

/26.3

A8

/26.4

A9

/26.4

A11

/26.4

A10

/26.4

<>

No. / Text

Siprotec 5 7UT85

module 5 (IO207)

Siprotec 5 7UT85

module 6 (IO207)

-F21.6

/25.3
/25.5

IO207

IO207

6
<2>

A12

/26.5

A13

/26.5

B1

/26.6

A14

/26.6

B2

/26.7

B3

/26.7

B5

/27.1

B4

/27.1

B6

/27.2

B7

/27.2

B9

/27.3

B8

/27.3

B10

/27.4

D5

/27.4

D7

/27.5

D6

/27.5

D8

/27.6

D9

/27.6

D11

/27.7

D10

/27.7

D12

1 )

BI 5.1

1 )

BI 5.2

B12 /1 9.4

BO 5.1

BO 5.2

BO 5.4

BI 5.4

1)

BI 5.5

1)

BI 5.6

BO 5.5

BO 5.6

BI 5.7

BO 5.7

1)

BO 5.8

BI 5.8

1)

BI 5.9

1)

BI 5.10

BO 6.1

1 )

BI 6.2

BO 6.2

BI 6.3

BO 6.3

B14 /1 9.4

/1 5.3

A2

/1 5.3

A5

/1 9.5

/1 5.6

A7

/1 5.6

A6

C3

/1 9.6

/1 5.6

A8

C6

/30.5

/30.1

A9

BO 6.4

1 )

BI 6.5

BO 6.5

1 )

BI 6.6

BO 6.6

BI 6.7

BO 6.7

/30.5

/30.1

A11

C8

/30.5

/30.2

A10

C11 /30.6

/30.2

C14 /30.7

/30.3

C13 /30.7

/30.3

Note 1

C1

C4
BI 6.4

C5

/30.2

C2

1 )

/1 9.6

C12 /30.6

B13

1 )

/1 5.6

/30.2

B11 /31 .2

A4

/1 9.5

/30.5

B12 /31 .2
B14

C4

C7

1)

BI 6.1

A3

C1

1)

1 )

/1 5.2

C2
BO 5.3

A1

B11 /1 9.4
B13 /1 9.4

1 )

BI 5.3

/1 5.2

Note 1

C3

C6

/36.3

C5

/36.3

C8

C7

A12

1 )

A13

C12

C11

B1
1 )

A1 4

BO 6.8

C13

B2
B3

1 )

C14

BI 6.8

BI 6.9

B5

B4

1 )

BI 6.1 0

B6

1 )

1)

B7

BI 5.11

BI 6.11

B9
1 )

1)

B8

BI 5.12

BI 6.12

B1 0

1)

BI 5.13

1 )

BI 5.14

D5

1 )

BI 6.13

D7

D6

1 )

BI 6.1 4

D8

1 )

1)

D9

BI 5.15

BI 6.15

1)

D10

1)

BI 5.16

BI 6.1 6

D12
1) USE THESE TERMINALS TO
ROOT THE BINARY INPUTS

Acceptance Code:

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

StWe

DETNORSKE
04L

As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Overview diagram
Siprotec module 5 and 6

Note 1

BO 6.3 mapped as test

pickup output

BO 6.4 mapped as test

trip output

D11

1) USE THESE TERMINALS TO


ROOT THE BINARY INPUTS

06L

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-45

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

45

DN02-S09011-E-XK-1002-45

Sheets:

58

/20.1 Heater
230 VAC

/20.2 Heater
230 VAC

X07:4

X07:5

Tripping coil 2
110 VDC L+
X07:22

/20.1 Heater
230 VAC

/1 3.6 Tripping coil 2


110 VDC L+
X07:28

X07:3

/1 3.7 Tripping coil 2


110 VDC L+
X07:30

244

243

53

233

54

234

224

A2

-F1

A1

A1

-KK4

-EB3

-EB2

-EB1

73
74

63

223

222

DC/AC

64

221

-M1

-BG1

A2

-KK3

A2

14

I>

83

43
44

84
X07:29

X06:27

-K1 0

X06:29

-K10

-K7

X06:4

21 71

-K7

X07:6

72 62

-K7

A1

13

61

-K10

22

Circuit breaker Q0 part 1


Type:

/1 3.1 DC motor
110 VDC L+

Tripping coil 1
110 VDC L+
X06:21

-QA9

A1

41

-BG|
103

-BG1

-QA9

-K7

Circuit breaker Q0

overview diagram

Part 1

I>

A2

-KK1

X06:3

/1 3.5 Tripping coil 1


110 VDC L+
X06:28
84
83

101
-BG1
1 02

-BG1

-F1

-BG1

104

52
42

DWG No: E50115-A0000-S014 (11-06-2013)

-BG1
94

-BG1

No. / Text

-BG1

93

22

14

-BG1

<>

/1 3.5 Tripping coil 1


110 VDC L+
X06:30

extended anti
pumping function
X06:20

13
-K7

51

61

-BG16
64

-BG1

21

63

62

X06:26

-Q0_1

53

+80EH0500+E03

54

Anti pumping
device 1

/1 3.6 Closing coil


110 VDCl L+

<1>

06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

/20.1

DC motor
L-

1
Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Overview diagram
Circiut breaker Q0

StWe

04L

Acceptance Code:

Drawing Title:

Supplier

HFO

/1 3.2

Tripping
/1 3.6
coil 2 L-

Closing
coil L-

/1 3.6

Tripping
/1 3.5
coil 1 L-

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-46

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

46

DN02-S09011-E-XK-1002-46

+E03

Sheets:

58

Motor running time


supervision

/23.2 Motor protection

General
lockout SF6

<>

No. / Text

Circuit breaker Q0

overview diagram

Part 2

X06:14

X06:15

/1 3.4
X07:13

X07:12

X06:23

/1 3.3

/1 3.4

Operation cycle
counter

Motor running
time supervision

X06:1

-Q0_2

/1 3.3

+80EH0500+E03

X06:22

/1 3.3

General
lockout SF6

Control Voltage
110 VDC L+

<1>

Spare

Loss of SF6

-X31

5
-BP1

31

11

25

32

33

12

13

28

-BP1

-WG1

22

62

-K67

26

21
-F1

-K1 0
214

12

21

61

213

22

11

-BG1

-BG16

-WG1

-WG1

-WG1

-K67

-X31

18

16

-X31

A1

X06:11

X06:10

/23.3

/23.2

/23.2

Control
voltage /1 3.4
110 VDC L-

X06:12

X06:2

X06:16

A2

-K67

60 s

A2

-QA9

A2

-K10

A1

15

-X31

Circuit breaker Q0 part 2


Type:

-WG1

A1

23

DGW No: E50115-A000-S014 (11-06-2013)

-WG1

-BP1

-X31

-X31

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Overview diagram
Circuit breaker Q0

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-47

+E03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

47

DN02-S09011-E-XK-1002-47

Sheets:

58

Auto reclosure
interlock

<>

No. / Text

Circuit breaker Q0

overview diagram

Part 3

X06:17

/22.6 General
loclout SF6
X07:15

+80EH0500+E03

/22.6 On-spring
unloaded

X07:10

<1>

-Q0_3

-BG16

-K10

54

62

72

-K1 0

53

61

71

21

81
-K10

22

33

-BG16

34

-BG16
82

DGW No: E50115-A000-S014 (11-06-2013)

X06:19

X06:18

X07:16

/22.6

/22.6

X07:11

Circuit breaker Q0 part 3


Type:

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Overview diagram
Circuit breaker Q0

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51 PO-041 93.21 0-K-1 02-48

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

48

DN02-S09011-E-XK-1002-48

+E03

Sheets:

58

<1>

<>

A
Circuit breaker on

Circuit breaker on

Circuit breaker off

Circuit breaker on

Circuit breaker off

Circuit breaker on

Circuit breaker off

Circuit breaker on

Circuit breaker off

Circuit breaker on

Circuit breaker off

X06:45

X07:39

X07:41

X07:43

X07:45

X07:31

X07:33

X07:35

X07:37

X06:31

X06:33

X06:35

X06:37

X06:24

123

131

133

141

143

151

153

161

163

171

173

181

183

19

/31 .6

X06:43
121

/1 2.2

Circuit breaker on

Circuit breaker off

X06:41
113

/32.3

/31 .5

Circuit breaker on

Circuit breaker off


/32.3

Circuit breaker on

X06:39

114

122

124

132

134

142

144

152

154

162

164

172

174

182

184

10

X06:42

X06:44

X06:46

X07:40

X07:42

X07:44

X07:46

X07:32

X07:34

X07:36

X07:38

X06:32

X06:34

X06:36

X06:38

X06:25

-BG1

112

X06:40

-Q0_4

Q0 Circuit breaker aux. switches

+80EH0500+E03

Circuit breaker Q0

overview diagram

auxilliary switches

111

/21 .2

/21 .2

Circuit breaker off

No. / Text

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Status switches
Circuit breaker Q0

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-49

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

49

DN02-S09011-E-XK-1002-49

+E03

Sheets:

58

/20.3 Heater
230 VAC

/23.4 Hand crank


cover open
X1:40

/1 6.2 DC motor
110 VDC L+

X1:1

X1:3

+80EH0500+E03

<1>

X1:32

/1 6.6 Control Voltage


110 VDC L+

/1 6.5 Disconnector on
X1:30

3
/1 6.5 Disconnector off

X1:5

<>

No. / Text

Disconnector Q1

overview diagram

14

14

27

13

28

13

61

61
62
21

62

1
2
54

22

21

21

-BG23

-EB1

-M1

13

-QA2

A1

-QA1

A1

A1/RD

22

22

-QA1

-QA2

-BG23

-EB2

14

73

/23.4

DC motor L- /16.2

/20.3

X1:6

X1:2

X1:41

74

-QA2

74

43

X1:4

83

83
-QA1

/1 6.5

-QA1

73

1u
44

44
43

-QA2

Control
voltage L-

X1:31

84

84
-QA2

-BG22

-QA1

A2/BK

A2

1o

A2

DC

Disconnector /1 6.5
on/off L-

-QA2

53

-QA1

53
DGW No: E50115-A0000-S024 (11-06-2013)
Disconnector Switch Q1
Type:

-QA2

-QA2

-QA1

-QA1

-BG1

54

-BG26
2

-BG25
16

-BG1

15

-Q1

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Overview diagram
Disconnector Q1

StWe

04L

Tag no.

Signature:

5
28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-50

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

50

DN02-S09011-E-XK-1002-50

+E03

Sheets:

58

<1>

<>

Disconnector on
make before break

Disconnector off
make before break

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector Q1

overview diagram

auxilliary switches

X1:46

X1:10

X1:12

X1:14

X1:16

X1:18

X1:20

X1:22

X1:24

X1:26

X1:28

X1:36

X1:38

X1:42

X1:44

43

51

53

61

63

71

73

81

83

91

93

101

103

135

147

/32.5

Disconnector on

Disconnector off

Disconnector on

Disconnector off
/32.4

Disconnector on

X1:7

+80EH0500+E03

41

/21 .3

/21 .4

Disconnector off

No. / Text

-BG1
44

52

54

62

64

72

74

82

84

92

94

102

104

136

148

X1:9

X1:11

X1:13

X1:15

X1:17

X1:19

X1:21

X1:23

X1:25

X1:27

X1:29

X1:37

X1:39

X1:43

X1:45

42

X1:8

Q1 Disconnector aux. switches

-Q1_1

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
17.03.15

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

1 1 0 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Status switches
Disconnector Q1

StWe

04L

Tag no.

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-51

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

51

DN02-S09011-E-XK-1002-51

+E03

Sheets:

58

Control Voltage
110 VDC L+

Hand crank
cover open

No. / Text

3-position switch QZ2

overview diagram

X1:40

X1:1

X1:5

<>

/23.4

Heater
230 VAC
/20.4

/1 7.1

/1 7.6

DC motor
110VDC L+

Earthing
switch on

Disconnector
off
/17.4
X1:32

/1 7.6

/1 7.5

4
<1>

X1:3

+80EH0500+E03

X2:32

X1:30

/1 7.4

Earthing
switch off

Disconnector
on

X2:30

As Built

13
61
22

-EB1

13
-BG23

-EB2

EsFr

EsFr
HFO

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Made by

Chc. by

Wood Group

Mustang

Appr. by

14

83

/20.4

/23.4

X1:2

X1:41

74

DC motor L- /1 7.2

SMOE

1
Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Overview diagram
3-position switch QZ2

StWe

Acceptance Code:

Drawing Title:

Supplier

HFO

1 4.1 1 .1 4

Date

73

83
X1:6

X2:31
/1 7.5
Earthing
switch
on/off L-

X1:4
/1 7.6
DSF

-QA2

74

43

-QA1

Contro
voltage L-

1 7.03.1 5

-QA1

73

44

44
43

-QA2

05.05.1 5

84

84
-QA2

-BG22

-QA1

A2/BK

A2

1o

A2

DC

As Built

-M1

A1/RD
A1

-QA2

04L

Description

62

62
21

32

22

22
A1

-QA1

DETNORSKE

Issue

61

13

-QA2

1u
05L

As Built

14

14

15
16
31

27

53
21

21
-QA1

-QA2

Disconnector /1 7.4
on/off L06L

-QA1

-BG23

X1:31

3-Position Switch QZ2


Type:

-QA2

-QA1

-BG1

53

28

32
DWG No: E50115-A0000-S055 (21-01-2013)

-QA2

28

-QA1

-BG2

54

27

54

16
31

-BG2

-BG26
2

-BG25

-BG1

15

-QZ2

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-52

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

52

DN02-S09011-E-XK-1002-52

+E03

Sheets:

58

-QZ2_2

06L

F
05L

Issue
Description

1
44

52

54

62

64

72

74

82

84

92

94

102

104

136

148

X2:9

X2:11

X2:13

X2:15

X2:17

X2:19

X2:21

X2:23

X2:25

X2:27

X2:29

X2:37

X2:39

X2:43

X2:45

X2:46

X2:10

X2:12

X2:14

X2:16

X2:18

X2:20

X2:22

X2:24

X2:26

X2:28

X2:36

X2:38

X2:42

X2:44

43

51

53

61

63

71

73

81

83

91

93

101

103

135

147

+80EH0500+E03

X2:7

As Built

As Built
/21 .6

/21 .6

41

05.05.1 5

1 7.03.1 5

Date

2
DSF

EsFr

Made by

EsFr

HFO

Chc. by

04L
As Built
1 4.1 1 .1 4
EsFr
HFO
StWe

03I
Issued for construction
1 5.07.1 4
EsFr
HFO
StWe

HFO

Supplier

StWe

DETNORSKE

SMOE

Wood Group

Mustang

Appr. by

4
5

102

104

136

148

X1:37

X1:39

X1:43

X1:45

147

135

103

101

93

91

83

81

73

71

63

61

53

51

X1:44

X1:42

X1:38

X1:36

X1:28

X1:26

X1:24

X1:22

X1:20

X1:18

X1:16

X1:14

X1:12

X1:10

X1:46

Disconnector on

Disconnector off

Disconnector on

/21 .5

/32.5

/32.6

Drawing Title:

1 1 0 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Status switches
3-position switch QZ2

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Disconnector on
make before break

Disconnector off
make before break

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector off

/21 .5

Earthing switch on
make before break

Earthing switch off


make before break

Earthing switch on

94

X1:29

74

X1:21

92

72

X1:19

X1:27

64

X1:17

84

62

X1:15

X1:25

54

X1:13

82

52

X1:11

43

X1:7

Earthing switch off

Earthing switch on

Earthing switch off

X1:23

44

X1:9

41

Earthing switch on

Earthing switch off

Earthing switch on

42

X1:8

Earthing switch off

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch off

42

X2:8

-QZ2_1

QZ2 Disconnector auxiliary switches

+80EH0500+E03

QZ2 Earthing switch aux. switches

1
<1>

6
7

Tag no.

80EC0503

<>

Area:
Scale

Siemens Dwg. No.:

M120
NA
51PO-04193.210-K-102-53

System:
DWG Size Drawing No.:
Rev:
Sheet:

80
A3

06L
53

DN02-S09011-E-XK-1002-53

P.O.Number

S0901 1

No. / Text

1
3-position switch QZ2

disconnector auxilliary

switches

2
3-position switch QZ2

earhing switch auxilliary

switches

<2>

Acceptance Code:

Date:
Signature:

28/05/15
David Stone

+E03

Sheets:

58

-BG1

-BG2

=80EC0503

Control Voltage
110 VDC L+

Hand crank
cover open

<>

No. / Text

3-position switch QZ9

overview diagram

X1:1

X1:40

/23.5

/20.5

Heater
230 VAC

DC motor
110VDC L+
/1 9.1

/1 9.6
X2:30

X1:32

/1 9.6

/1 9.4

Earthing
switch on

Disconnector
off

<1 >

X1:3

+80EH0500+E03

X2:32

X1:30

/1 9.5

/1 9.4

Earthing
switch off

Disconnector
on

X1:5

13
61

61

13

62

21

32

62

-QA2

22

EsFr

EsFr
HFO

As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Made by

Date

Chc. by

SMOE

X1:41

Drawing Title:

Tag no.

Wood Group

Mustang

Installation: Ivar Aasen Field

Development Project - PDQ Platform

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Overview diagram

3-position switch QZ9

Appr. by

/23.5

X1:2

StWe

04L

Acceptance Code:

Supplier

HFO

14

83
73
74

/20.5

/1 9.2
DC motor L-

X1 :6

X2:31
/1 9.5
Earthing
switch
on/off L-

X1:4
/1 9.6
Contro
voltage L1 7.03.1 5

DSF

-QA2

74

43

-QA1

05.05.1 5

84

84
83

-QA2
43

As Built

-QA1

73

44

44
-QA1

A2/BK

A2

A2
1o

-QA2

-BG22

As Built

Description

-BG23

-EB2

DC

DETNORSKE

Issue

-EB1

-M1

13

-QA2

A1

-QA1

A1

A1/RD

22

22

1u
05L

14

14

15
16
31

27

53
21

21
-QA1

-QA2

Disconnector /1 9.4
on/off L06L

-QA1

-BG23

X1:31

3-Position Switch QZ2


Type:

-QA2

-QA1

-BG1

53

28

32
DWG No: E50115-A0000-S055 (21-01-2013)

-QA2

28

-QA1

-BG2

54

27

54

16
31

-BG2

-BG26
2

-BG25

-BG1

15

-QZ9

Date:

Signature:

28/05/15

David Stone

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-54

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

54

DN02-S09011-E-XK-1002-54

+E03

Sheets:

58

+80EH0500+E03

-QZ9_2

06L

F
05L

Issue
Description

As Built

As Built
X2:10

X2:16

X2:18

X2:20

X2:28

X2:36

X2:38

51

53

61

63

71

73

81

83

91

93

101

103

135

147

52

54

62

64

72

74

82

84

92

94

102

104

136

148

X2:11

X2:13

X2:15

05.05.1 5

1 7.03.1 5

Date

2
DSF

EsFr

Made by

X2:17

X2:19

X2:21

X2:23

X2:25

EsFr

HFO

Chc. by

04L
As Built
1 4.1 1 .1 4
EsFr
HFO
StWe

03I
Issued for construction
1 5.07.1 4
EsFr
HFO
StWe

HFO

X2:27

Supplier

StWe

DETNORSKE

SMOE

Wood Group

Mustang

Appr. by

4
X2:29

X2:37

X2:39

X2:43

X2:45

Drawing Title:

1 1 0 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Status switches
3-position switch QZ9

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Earthing switch on
make before break

92

94

102

104

136

148

X1:29

X1:37

X1:39

X1:43

X1:45

74

X1:21

X1:27

72

X1:19

147

135

103

101

93

91

83

81

73

71

63

61

53

51

43

X1:44

X1:42

X1:38

X1:36

X1:28

X1:26

X1:24

X1:22

X1:20

X1:18

X1:16

X1:14

X1:12

X1:10

X1:46

X1:7

Disconnector on

/22.2

Disconnector on
make before break

Disconnector off
make before break

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector off

/22.2

X2:44

Earthing switch off


make before break

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch off

64

X1:17

84

62

X1:15

X1:25

54

X1:13

82

52

X1:11

X1:23

44

X1:9

41

X2:42

X2:26

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch off

Earthing switch on

42

X1:8

X2:24

Earthing switch on

/22.4

Earthing switch off

Earthing switch off

/22.3

X2:22

X2:14

X2:12

X2:46

43

44

-BG2

X2:9

X2:7

41

42

X2:8

-QZ9_1

QZ2 Disconnector auxiliary switches

+80EH0500+E03

QZ2 Earthing switch aux. switches

1
<1 >

6
7

Tag no.

80EC0503

<>

Acceptance Code:

Area:
Scale

Siemens Dwg. No.:

M120
NA
51PO-04193.210-K-102-55

System:
DWG Size Drawing No.:
Rev:
Sheet:

80
A3

06L
55

DN02-S09011-E-XK-1002-55

P.O.Number

S0901 1

No. / Text

1
3-position switch QZ9

disconnector auxilliary

switches

2
3-position switch QZ9

earhing switch auxilliary

switches

<2>

5
28/05/15

Date:

+E03

Sheets:

58

-BG1

David Stone

Signature:

=80EC0503

/23.6 Hand crank


cover open

<>

No. / Text

Earthing switch Q8

overview diagram

X1:1

X1:40

/20.7 Heater

/1 8.2 DC motor L+
X1:5

X1:3

+80EH0500+E03

X1:32

/1 8.6 Control
Voltage L+

/1 8.5 Command on
X1:30

/1 8.5 Command off

<1>

14

14

13

13

61

61

53

2o

62

62

22

22

2u

-EB1

-BG26

-M1

21

-QA2

A1

-QA1

A1

A1

-BG25

-BG22

-EB2

/23.6

X1:2
/20.7

X1:41

74

X1:6
DC motor L- /1 8.2

Control
/1 8.5
Voltage L-

22

83

73

-QA2

74

43

X1:4

73

14
44

44

-QA1

-QA1

-QA2
43

84

84
-QA2
83

-BG23

-QA1

A2

A2

13

A2

DC

Command L- /1 8.5

-QA2

-BG23

X1:31

-QA1

-QA1

-QA2

DGW No: E50115-A0000-S044 (21-01-2013)


High speed earthing switch Q8
Type:

-QA2

21

21

-QA1

-QA2
53

-QA1

54

54

-Q8

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Overview diagram
Earth switch Q8

StWe

04L

Tag no.

Signature:

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-56

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

56

DN02-S09011-E-XK-1002-56

+E03

Sheets:

58

<1>

<>

Earthing switch on
make before break

Earthing switch off


make before break

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch Q8

overview diagram

auxilliary switches

X1:44

X1:42

X1:38

X1:36

X1:28

X1:26

X1:24

X1:22

X1:20

X1:18

X1:16

X1:14

/22.5

X1:12

+80EH0500+E03

X1:10

X1:7

/22.5

X1:46

Earthing switch off

No. / Text

97

85

73

71

63

61

53

51

43

41

33

31

23

21

13

11

14

22

24

32

34

42

44

52

54

62

64

72

74

86

98

X1 :9

X1:11

X1:13

X1:15

X1:17

X1:19

X1:21

X1:23

X1:25

X1:27

X1:29

X1:37

X1:39

X1:43

X1:45

-BG1

/22.5

/22.5

12

X1:8

Q8 High speed earthing switch

-Q8_1

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EC0503

1 1 0 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Status switches
Earth switch Q8

StWe

04L

Tag no.

Signature:

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-57

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

57

DN02-S09011-E-XK-1002-57

+E03

Sheets:

58

<1>

<>

No. / Text

Spare terminals

23

22

-X31

52

51

B
A

B
A

345

B
A

344

343

255

254

253

B
A

252

251

249

248

247

246

B
A

245

244

B
A

95

94

93

92

91

90

89

70

69

B
A

25

B
A

A
-X32

B
A

24

B
A

54

21

-X30

22

23

53

-X24

Acceptance Code:

1
06L

05L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 4.1 1 .1 4

EsFr

HFO

StWe

03I

Issued for construction

1 5.07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EC0503

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, FEEDER TO


TRANSFORMER 80ET0100A

Spare Terminals
.

StWe

04L

Tag no.

Signature:

David Stone

5
28/05/15
=

S0901 1

=80EC0503

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-102-58

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

06L

58

DN02-S09011-E-XK-1002-58

+E03

Sheets:

58

Potrebbero piacerti anche