Sei sulla pagina 1di 1

Byco Oil Pakistan Ltd

Mouza Kund, Hub

DATA SHEET FOR


STEAM CONDENSER EJECTOR

DATA SHEET NO. BOPL-EJR-DS-01


SHEET NO.
1 OF 1
DATE 17/01/2014
Rev.
PREPARED BY
SMA
CHECKED BY
MS
APPROVED BY
RZ

STEAM CONDENSER EJECTOR


Items

Tag Number
Quantity Required
VENDOR
Type
Make
Model

Units

No.
-

Requirement

Condenser:
Yes

21H-1/1A

VTA
Any wellknown OEM
VTA

Ejector type:
Single Stage Single Element

OPERATING CONDITION( PER UNIT)


ENTRAINED GAS
Type of gas
Dry Gas (air)
Water Vapor (steam)
Total Gas
Inlet temperature
Inlet Pressure
Discharge pressure

Lbs/hr
Lbs/hr
Lbs/hr
Deg F
psia

psia

Air- Steam Mixture


87
211
298
170
5.8

Weight:
VTA

15.5
Accessories and materials (VTC)
Gas Inlet Valve

MOTIVE STEAM
Design pressure
Maximum pressure
Minimum pressure
Design Temperature
Maximum temperaure
Stem consumption

Testing:
Performance MFR`s STD.
Hydrostatic Per H.E.I

psig
psig
psig
Deg F
Deg F

Lbs/Hr

180
200
150
Saturated
531

See Exchanger datasheet

COOLING WATER

CONNECTION (size & rating)


Steam inlet
Gas Inlet
Gas outlet

ASA
ASA
ASA

VTA
VTA
VTA

Ejector Material
Diffuser
Suction Chamber
Steam Nozzle
Nozzle Extensions
Steam Chest
Nozzle Plate

Steel(VTC)
Steel(VTC)
Steel(VTC)
X 22 Cr Mo V (VTC)
Steel(VTC)
Steel(VTC)

Note:
1 VTA = Vendor to advice
2 VTC = Vendor to confirm
3 The Ejector and all auxilliaries should conform to H.E.I. (Heat Exchanger Institute) specifications