Contents
Water Filters
QPoint
Pall-Aquasafe
Pre-Filtration
10
QPData
11
11
PCR Technology
12
Infusion Filters
13
15
16
18
19
20
www.pall.com/medical
QPoint
Product description
Order code I Description
Packaging
Membrane area (nominal)
Flow rates (nominal)
1 unit/pkg
Not applicable
Not applicable
Diameter (nominal)
Weight (nominal)
Temperature
88 mm (3.5 in)
84 g (2.96 oz)
Continuous influent temperature 60 C (140 F) during
product installation
Maximum influent temperature 75 C (167 F) for a total
cumulative period of 90 minutes over the life of each
connected Filter Capsule
5 bar (75 psi) at continuous 60 C (140 F) influent
temperature
Reusable
External surfaces may be cleaned using common
sanitising agents.
During routine water system disinfection the Docking
Station with attached Filter Capsule can be left in place
to enable the outlet to be flushed
Polycarbonate/Acrylonitrile Butadiene Styrene (51%), Glass
Filled Nylon (22%), Polyester (20%), Stainless Steel (4%)
Recycled cardboard outer packaging
www.pall.com/medical
Pall-Aquasafe
Disposable Water Filters
Product description
Order code I Description
Packaging
Temperature
Maximum upstream
operating pressure
Maximum filter life
Sanitisation
www.pall.com/medical
Pall-Aquasafe
Disposable Water Filters (continued)
Product description
Order code I Description
Packaging
Membrane area (nominal)
Flow rates (nominal)
Length (excluding quick
connect adaptor - nominal)
Temperature
Maximum upstream
operating pressure
Maximum filter life
Sanitisation
31 days
Compatible with common surface and systemic
disinfection programs. Complementary to water safety
plan sanitisation and hygiene protocols
www.pall.com/medical
Product description
Order code I Description
Product description
Order code I Description
Product description
Order code I Description
Product description
Order code I Description
www.pall.com/medical
Product description
Wash basin
Miscellaneous
TAPUC Universal connector (15-29 mm)
Product description
Order code I Description
Product description
Order code I Description
Product description
Order code I Description
www.pall.com/medical
Product description
Order code I Description
Product description
Order code I Description
Accessories
Product name
Product description
Order code I Description
Packaging
Maximum filter life
Maximum continuous
influent water temperature
Maximum upstream
operating pressure
Product description
Order code I Description
Product description
Order code I Description
www.pall.com/medical
Pre-Filtration
Pall pre-filtration technologies can be installed either at the point of entrance or in-line within a building. They significantly reduce the amount of incoming
organic and inorganic particles, which may contribute to biofilm growth in your water distribution system. Furthermore, Pall pre-filtration technologies help
to protect your point-of-use (POU) filters from reduced longevity due to high particulate contamination.
Flow reduction or blockage of POU filters before their maximum lifetime is a strong indicator of heavy colloid and/or particulate load in your water distribution
system and highlights a need to perform additional water profile tests on the water quality such as silt density tests (SDI).
Pall Medical offers technical services such as SDI testings in your facilities. Based on those tests, suitable pre-filtration technologies can be selected from
a large Pall pre-filter portfolio. A selection of Pall pre-filtration technologies are described below. For further information, as well as ordering information,
please contact your local Pall Medical office.
Product name
Product description
Product name
Product description
www.pall.com/medical
Product Name
Order code I Description
Packaging
Membrane area (nominal)
www.pall.com/medical
10
QPData
Product description
Order code I Description
Please note:
Data SIM card and/or contract is not included. The warranty of any hardware supplied by Microsec
and/or Pall is limited to the Manufacturers warranty.
Water Testing
Particle Analysis in Water Distribution Systems
Water distribution systems, particularly in older or large buildings may contain high levels of organic and inorganic material in the form of particles (such as,
sand, silicates, rust) and colloids. Those water contaminants may contribute to biofilm formation or be derived from already established biofilm within the
system. The particulate load in the water may visibly change the water colour. The turbidity of the water represents an indicator of the particulate/colloidal
concentration in the system.
Particulate and colloidal load in water distribution systems can be analyzed using the Silt Density Index test (SDI). Pall Life Sciences offers SDI testing in your facilities
by our specialists. Based on the individual review of the SDI report, system specific and cost effective prefiltration technologies can be selected from a large
Pall pre-filter portfolio in order to deliver maximum benefits for your water distribution system. Please contact your local Pall representative in order to find out
if an SDI test can be performed in your facility.
Please note: Flow reduction or blockage of POU sterilizing grade filters before their intended lifetime may indicate a high particulate
load in the water distribution system.
Filter Replacement
Pall Medical offers service to exchange Pall point-of-use filters and large-scale prefilter cartridges in your facility.
Due to the use of quick connectors, point-of-use filter exchange can be performed easily within seconds by trained cleaning or facilities maintenance staff,
nursing staff, or other trained persons. However, if desired and where possible, Pall Medical offers the option to exchange filters in your facility. This can be
performed using professional external technical service and cleaning companies in your area.
The exchange of Pall large-scale prefilter cartridges in cooperation with the technician in your facility may also be available.
Please contact your local Pall sales office in order to obtain more information about the availability of filter
exchange services in your area.
Turnkey Program
In some locations, Pall Medical offers a Turnkey Program that includes particulate water testing, microbial water analysis, filter replacement and
additional services.
Please contact your local sales office in order to obtain detailed information about this program and availability
of this service in your area.
www.pall.com/medical
11
PCR Technology
Product name
Product description
Ordering information
Technical data
For information on the analytical discs, please contact your local sales office or visit www.pall.com.
www.pall.com/medical
12
Infusion Filters
Product name
Product description
Order code I Description
Packaging
Volume
Membrane
Filter and tubing
Special features
Maximum filter life
Information for use
0.4 mL
AEF1E
1.0 mL
AEF1NTE
0.7 mL
0.2 m Supor membrane
Non-phthalate fluid pathway,
free of latex
Air elimination
24 h
Single patient use
www.pall.com/medical
13
Product name
Product description
TNA1E
0.9 mm ID microbore tubing,
luer connectors
Packaging
Volume
Membrane
Filter and tubing
Special features
Maximum filter life
Information for use
www.pall.com/medical
14
Product name
Product description
Packaging
Membrane | Pore size
Housing
Housing diameter
Connectors
Membrane area
Volume
Free of latex
HP2002
HP2402
Acrylic
25 mm
Acrylic
n/a
n/a
n/a
Yes
Yes
www.pall.com/medical
15
Product name
Product description
BB25
With monitoring port
BB25G
With monitoring port (bulk pack)
BB25S
With monitoring port, sterile
BB25GS
With monitoring port, sterile
(bulk pack)
BB25F
With monitoring port, flex tube
and flex tube cap
BB25FG
With monitoring port, flex tube
and flex tube cap (bulk pack)
BB25FS
With monitoring port, flex tube
and flex tube cap, sterile
BB25FU
With monitoring port and flex tube
BB25FGU
With monitoring port and flex tube
(bulk pack)
BB2000AP
With monitoring port, expandable
catheter mount (with two straight
connectors) and catheter mount cap
BB2000APS
With monitoring port, expandable
catheter mount (with two straight
connectors) and catheter mount
cap, sterile
BB100E
BB100ES
Sterile
BB100EF
With flex tube and flex tube cap
BB100EFS
With flex tube and flex tube cap, sterile
BB100P
With monitoring port
BB100PS
With monitoring port, sterile
BB100PF
With monitoring port, flex tube and flex tube cap
BB100PFS
With monitoring port, flex tube and flex tube cap, sterile
Packaging
Bulk pack
Filter media
BB2000APN
With monitoring port, expandable
catheter mount (with two straight
connectors), and fixed non-ported
elbow
BB25D
With monitoring port, flex tube
and fixed non-ported elbow
BB25DG
With monitoring port, flex tube
and fixed non-ported elbow (bulk
pack)
BB25Y
With monitoring port, and catheter
mount (with straight connector at
the filter end and fixed elbow, with
access port and cap, at the
patient end)
BB25CG
With monitoring port and catheter
mount (with straight connector at
the filter end and fixed, non-ported elbow connector at the patient
end). (bulk pack)
BB25N
With monitoring port and fixed,
non-ported elbow
BB25NG
With monitoring port and fixed,
non-ported elbow (bulk pack)
35 mL
100%
>99.999%
99.999%
Weight
Recommended use
Free of latex
Yes
Approx. 1 cm H2O
Approx. 2 cm H2O
Patient end 15 mm female / 22 mm male
Machine end 22 mm female
47 g
Patient end use only, max 24 h if nebulisation is used, use may
be extended to a maximum of 48 hours when nebulisation is not
used, single patient use
Yes
Filter volume
Filtration efficiency for
liquidborne bacteria/viruses
Filtration efficiency for
airborne bacteria/viruses
Resistance @ 30 L/min
Resistance @ 60 L/min
Filter ISO connectors
www.pall.com/medical
16
Product name
Product description
BB22-15
BB22-15G
(bulk pack)
BB22-15S
Sterile
BB22-15F
With flex tube and flex tube cap
BB22-15M
With monitoring port
BB22-15MG
With monitoring port (bulk pack)
BB22-15MS
With monitoring port, sterile
BB22-15MF
With monitoring port, flex tube and flex tube cap
BB22-15MFS
With monitoring port, flex tube and flex tube cap, sterile
50 units per case
BB50TE
Machine end applications in breathing systems and
gas line applications
BB50TBL
Gas line applications
BB50TES
For machine end applications in breathing systems and
gas line applications (e.g., insufflation), sterile
BB50TESD
BB50TES in double pouch
BB50TP
As per BB50TE applications but also for use with
Puritan Bennett oxygen concentrators
Packaging
>99.999%
>99.999%
Weight
Recommended use
Approx. 1 cm H2O
Approx. 2.5 cm H2O
Patient end 15 mm female / 22 mm male
Machine end 22 mm female / 15 mm male
43 g
Max. 24 h single patient use
Free of latex
Yes
Approx. 1 cm H2O
Approx. 2 cm H2O
Patient end 22 mm male
Machine end 22 mm female
39 g
BB50TE, BB50TP, BB50TES, BB50TESD: Max. 24 h
in connection with a high-efficiency HME (heat and
moisture exchanger) extended use may be permitted
Yes
Bulk pack
Filter media
Filter volume
Filtration efficiency for
liquidborne bacteria/viruses
Filtration efficiency for
airborne bacteria/viruses
Resistance @ 30 L/min
Resistance @ 60 L/min
Filter ISO connectors
www.pall.com/medical
17
Product name
Product description
Order code I Description
Packaging
Bulk pack
Filter media
Filter volume
Cross contamination
reduction efficiency
Resistance @ 12 L/sec
Connectors
Weight
Recommended use
Free of latex
0.6 cm H2O
30 mm female or 30 mm modified female depending
upon variant
26 g
Single patient use
Yes
0.6 cm H2O
30 mm female or 30 mm modified female depending
upon variant
26 g
Single patient use
Yes
www.pall.com/medical
18
Product name
Product description
IGF1
7.5 cm silicone tubing and luer
connector inlet (f),
52.5 cm silicone tubing and luer
connector outlet (m), sterile double
peel-pouch
IGF1E
7.5 cm PVC tubing and luer connector
inlet (f), 52.5 cm PVC tubing and
luer connector outlet (m), sterile
double peel-pouch
IGF1L
7.5 cm PVC tubing and luer connector
inlet (f), 250 cm PVC tubing and luer
connector outlet (m), sterile double
peel-pouch
IGF1M
7.5 cm PVC tubing and luer connector
inlet (m), 250 cm PVC tubing and
luer connector outlet (f), sterile
single peel-pouch
IGF1C
7.5 cm PVC tubing and suction
connector inlet (f), 250 cm PVC tubing
and luer connector outlet (m), sterile
single peel-pouch
IGF1CD
7.5 cm PVC tubing and suction
connector inlet (f), 250 cm PVC tubing
and luer connector outlet (m), sterile
double peel-pouch
IGF1K
10 cm silicone tubing and luer
connector inlet (f), 10 cm silicone
tubing and luer connector outlet (m),
10 cm silicone tubing, sterile single
peel-pouch
20 units per case
Hydrophobic media manufactured
using silicone resin bonded man-made
mineral fibres
Packaging
Filter media
Housing
Tubing
Bacteria filtration efficiency
(airborne)
Viral filtration efficiency for
viruses (airborne)
Acrylic
PVC or silicone depending upon
variant
>99.999%
>99.99%
Acrylic
PVC
www.pall.com/medical
19
Product name
Product description
Order code I Description
Packaging
Filter membrane
Housing
Acrylic
Tubing
Bacteria filtration efficiency
(airborne)
Viral filtration efficiency for
viruses (airborne)
n/a
>99.999%
>99.99%
www.pall.com/medical
20
International Offices
Pall Corporation has offices and plants throughout the world in locations such as: Argentina, Australia, Austria, Belgium,
Brazil, Canada, China, France, Germany, India, Indonesia, Ireland, Italy, Japan, Korea, Malaysia, Mexico, the Netherlands,
New Zealand, Norway, Poland, Puerto Rico, Russia, Singapore, Spain, Sweden, Switzerland, Taiwan, Thailand, the
United Kingdom, the United States, and Venezuela. Distributors in all major industrial areas of the world. To locate the
Pall office or distributor nearest you, visit www.pall.com/contact. This document is not for distribution in the USA.
(877) 367-7255
safewater@pall.com
The information provided in this literature was reviewed for accuracy at the time of publication. Product data may
be subject to change without notice. For current information consult your local Pall distributor or contact Pall directly.
Part numbers quoted are protected by the Copyright of Pall Europe Ltd.
phone
email
phone
email
phone
email
09.4289d EU