Sei sulla pagina 1di 2

DEEP SEA ELECTRONICS

7 3 2 0 I NST AL L AT I O N I N ST RU CT I O N S

TYPICAL WIRING DIAGRAM

053-029
ISSUE 10

ACCESSING THE FRONT PANEL CONFIGURATION EDITOR

Ensure the engine is at rest and the module is in STOP mode by pressing the Stop/Reset

Press the Stop/Reset


and Info
buttons simultaneously.
If a module security PIN has been set, the PIN number request is then
shown :

button.

Press
, the first # changes to 0. Press
correct value.

Press
(right) when the first digit is correctly entered. The digit you have just entered will now
show # for security.

(up) or

(down) to adjust it to the

Repeat this process for the other digits of the PIN number. You can press
move back to adjust one of the previous digits.

(left) if you need to

When
is pressed after editing the final PIN digit, the PIN is checked for validity. If the number is
not correct, you must re-enter the PIN.
If the PIN has been successfully entered (or the module PIN has not been
enabled), the editor is displayed :

EDITING A PARAMETER

Enter the editor as described above.


Press the left or right buttons to cycle to the section you wish to view/change.
Press the up or down buttons to select the parameter you wish to view/change within the currently
selected section.

To edit the parameter, press


to enter edit mode. The parameter begins to flash to indicate that
you are editing the value.
Press the up or down buttons to change the parameter to the required value.

Press

To exit the editor at any time, press and hold the

Deep Sea Electronics Plc.

Deep Sea Electronics inc.

Tel:+44 (0)1723 890099


Fax: +44 (0)1723 893303
Email: support@deepseaplc.com
Web: www.deepseaplc.com

Phone: +1 (815) 316-8706


Fax: +1 (815) 316- 8708
TOLL FREE (USA only) : Tel: 1 866 636 9703
Email: dsesales@deepseausa.com
Web: www.deepseausa.com

to save the value. The parameter ceases flashing to indicate that it has been saved.
button.

NOTE: When the editor is visible, it is automatically exited after 5 minutes of inactivity to ensure
security.
NOTE: The PIN number is automatically reset when the editor is exited (manually or automatically) to
ensure security.
NOTE: More comprehensive module configuration is possible using the 7xxx series PC configuration
software. Please contact us for further details

ADJUSTABLE PARAMETERS (Configuration editor)


Section Parameter as shown on display
Factory Settings
Contrast
Language
LCD Page Timer
Auto Scroll Delay
Current Date and time
EDITOR
Alt Config
ENGINE
Oil Pressure Low Shutdown
Oil Pressure Low Pre Alarm
Coolant Temperature Low Warning
Coolant Temperature High Pre Alarm
Coolant Temperature High Shutdown
Start Delay Off Load
Start Delay On Load
Start Delay Mains Fail
Start Delay Telemetry
Start Delay Timer
Crank Duration Timer
Crank Rest Timer
Safety On Delay
Smoke Limiting
Smoke Limiting Off
Warm Up Timer
Cool Down Timer
Engine Under Speed Shutdown
Engine Under Speed Shutdown
Engine Under Speed Warning
Engine Under Speed Warning
Engine Over Speed Warning
Engine Over Speed Warning
Engine Over Speed Shutdown
Engine Speed Overshoot Delay
Engine Speed Overshoot
Fail To Stop Delay
Battery Under Voltage Warning
Battery Under voltage Warning Delay
Battery Under Voltage
Battery Over Voltage Warning
Battery Over Voltage Warning Delay
Battery Over Voltage Warning
Charge Alternator Failure Warning
Charge Alternator Failure Warning
Charge Alternator Warning Delay
Charge Alternator Failure Shutdown
Charge Alternator Failure Shutdown
Charge Alternator Shutdown Delay
Droop control
Droop control
DPTC Auto Regeneration Inhibit
Fuel Usage Alarm (Running Rate)
Fuel Usage Alarm (Stopped Rate)
GENERATOR Generator Under Voltage Shutdown
Generator Under Voltage Pre Alarm
Generator Nominal Voltage
Generator Over Voltage Pre Alarm
Generator Over Voltage Shutdown
Generator Under Frequency Shutdown
Generator Under Frequency Pre Alarm
Generator Nominal Frequency
Generator Over Frequency Pre Alarm
Generator Over Frequency Shutdown
Full Load Rating
KW Overload Trip
Delayed Over Current
Delayed Over Current
AC System
CT Primary
CT Secondary
Earth CT Primary
Earth Fault Trip
Earth Fault Trip
Generator transient delay
DISPLAY

0%
English
0h 0m 0s
0h 0m 0s
hh:mm
Default Config
0.00bar
0.00bar
0C
0C
0C
0h 0m 0s
0h 0m 0s
0h 0m 0s
0h 0m 0s
0h 0m 0s
0m 0s
0m 0s
0m 0s
0m 0s
0m 0s
0m 0s
0h 0m 0s
Active / Inactive
0 rpm
Active / Inactive
0 rpm
Active / Inactive
0 rpm
0 rpm
0m 0s
0%
0m 0s
Active / Inactive
0h 0m 0s
0V
Active / Inactive
0h 0m 0s
0V
Active / Inactive
0V
0h 0m 0s
Active / Inactive
0.0 V
0h 0m 0s
Active / Inactive
0% (Compatible engine ECUs only)
Active / Inactive
0% - 100% ( If Fuel Sender Configured)
0% - 100% ( If Fuel Sender Configured)
0V
0V
0V
0V
0V
0 Hz
0 Hz
0 Hz
0 Hz
0 Hz
0A
0%
Active / Inactive
0%
3 Phase, 4 Wire
0A
0A
0A
Active / Inactive
0%
0s

Front Panel Configuration Editor (continued)

Section Parameter as shown on display Factory Settings


MAINS

TIMERS

SCHEDULE

Mains Under Voltage Trip


Mains Over Voltage Trip
Mains Under Frequency Trip
Mains Over Frequency Trip
Mains Transient Delay
Return Delay
Mains Transfer Time
LCD Page Timer
Auto Scroll Delay
Pre Heat Timer
Crank Duration Timer
Crank Rest Timer
Safety On Delay
Smoke Limiting
Smoke Limiting Off
Warm Up Timer
Cool Down Timer
Speed Overshoot Delay
Fail To Stop Delay
Battery voltage Low Warning Delay
Battery Voltage High Warning Delay
Return Delay
Generator Transient Delay
Mains Transient Delay
Mains Transfer Time
Schedule
Schedule On Load
Schedule Period

0V
0V
0 Hz
0 Hz
0m 0s
Oh 0m 0s
0m 0.0s
0h 0m 0s
0h 0m 0s
0m 0s
0m 0s
0m 0s
0m 0s
0m 0s
0m 0s
0h 0m 0s
0h 0m 0s
0m 0s
0m 0s
0h 0m 0s
0h 0m 0s
0h 0m 0s
0s
0m 0s
0.0s
Active, Inactive
Active, Inactive (only available when Scheduler is active)
Weekly, Monthly, (only available when Scheduler is active

Schedule time and Date Selection (1-16)

Press
to begin editing then up or down when selecting the
different parameters in the scheduler.

ACCESSING THE RUNNING CONFIGURATION EDITOR

The running editor can be entered while the engine is running. All protections remain active if the

engine is running while the running editor is entered.

Press and hold the

button to enter the running editor.

EDITING A PARAMETER

Enter the editor as described above.

Press the left or right buttons to cycle to the section you wish to view/change.
Press the up or down buttons to select the parameter you wish to view/change within the currently

selected section.

To edit the parameter, press


to enter edit mode. The parameter begins to flash to indicate that
you are editing the value.
Press the up or down buttons to change the parameter to the required value.

Press

To exit the editor at any time, press and hold the

to save the value. The parameter ceases flashing to indicate that it has been saved.
button.

ADJUSTABLE PARAMETERS (Running editor)

Section Parameter as shown on display

Factory Settings

DISPLAY

53%
English
0.0Hz

ENGINE

Contrast
Language
Manual Frequency Trim (Electronic engines only)

DIMENSIONS AND MOUNTING


For flat surface mounting in a Type 1 enclosure to meet UL requirements
DIMENSIONS
240.0mm x 181.1mm x 41.7mm (9.4 x 7.1 x 1.6)

PANEL CUTOUT:
220mm x 160mm (8.7 x 6.3)