Sei sulla pagina 1di 28

technical data

Systems
FXUQ-MV1 & BEVQ-MVE
4-way blow ceiling suspended unit

Indoor Units 4-WAY BLOW CEILING SUSPENDED UNIT FXUQ-MV1

TABLE OF CONTENTS
FXUQ-MV1

s g n i l i e s c s m t e w it o ns l Uy b1 S V r M yoI - aoI Q wdVU n-RX IV4F

Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Safety device settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Control systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Cooling capacity tables
Heating capacity tables

...............................................6
...............................................7

Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Piping diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Sound pressure spectrum

10

Air flow pattern . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14


Air flow pattern - Cooling
Air flow pattern - Heating

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Junction box - BEVQ-MVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20


Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Piping diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

VRVII Systems Indoor Units

Indoor Units 4-WAY BLOW CEILING SUSPENDED UNIT FXUQ-MV1

V r M yoI - aoI Q wdVU n-RX 1


IV4F

Features

Group control with other VRV indoor units possible

Air can be discharged in any of 4 directions

Cool heat selection

Possibility to shut 1 or 2 flaps for easy installation in corners

Prevention of cold draught at hot start, defrost and oil return in


heating

5m maximum distance between FXUQ unit and junction box

Air can be discharged at 5 different angles between 0 and 60 degrees

5m

BRC1D527

VRVII Systems Indoor Units

Auto-swing function ensures efficient air and temperature


distribution.

Air flow distribution for ceiling heights up to 3.5m without loss of


capacity.

Air filter, drain pan and heat exchanger fin are mildew proof and antibacterial treated.

Indoor Units 4-WAY BLOW CEILING SUSPENDED UNIT FXUQ-MV1

Specifications

3
2-1 TECHNICAL SPECIFICATIONS
Power input
(Nominal)
Casing
Dimensions

FXUQ71MV1

FXUQ100MV1

Cooling

kW

0.180

0.289

0.289

Heating

kW

0.160

0.269

0.269

Colour

White

Material

Resin

Packing

Unit

Weight
Heat
Exchanger

Height

mm

230

295

295

Width

mm

960

960

960
960

Depth

mm

960

960

Height

mm

165

230

230

Width

mm

895

895

895

Depth

895

mm

895

895

Machine Weight

kg

25

31

31

Gross Weight

kg

35

42

42

mm

2101

2101

2101

1.50

1.50

1.50

Dimensions

Length
Nr of Rows
Fin Pitch

mm

Nr of Passes

12

0.265

0.353

0.353

Nr of Stages

Empty Tubeplate
Hole

m2

Face
Area

Fin
Fan

Fin type

Cross fin coil (Multi louver fins and N-hix tubes)

Type

Fan

Cooling

High

19.00

29.00

32.00

Low

14.00

21.00

23.00

Heating

High

19.00

29.00

32.00

Low

14.00

21.00

23.00

Motor

Steps
Output
(high)

dBA

45

90

90

Refrigerant

Name

Sound Level

Cooling

Sound
power
(nominal)

Cooling

Sound
Pressure

High

dBA

40.0

43.0

44.0

Low

dBA

35.0

38.0

39.0

Sound
Pressure

High

dBA

40.0

43.0

44.0

Low

dBA

35.0

38.0

39.0

mm

9.5

Heating
Piping
connections

Liquid (OD)

R-410A
59.0

60.0

Flare connection

Gas

Type
Diameter

mm

Drain

Diameter

mm

Infrared

56.0

Type
Diameter

9.5

9.5

Flare connection

Heat Insulation
Remote
Control

Turbo fan

Quantity
Air Flow Rate

FXUQ125MV1

15.9

15.9

15.9

I.D. 20/O.D. 26
Heat resistant foamed polyethylene, regular foamed polyethylene

Cooling only
Heating only

Air Filter

BRC7C529W
BRC7C528W
Resin net with mold resistance

Safety devices

Fan motor thermal protector

VRVII Systems Indoor Units

Indoor Units 4-WAY BLOW CEILING SUSPENDED UNIT FXUQ-MV1

2-1 TECHNICAL SPECIFICATIONS


Standard
Accessories

FXUQ71MV1

FXUQ100MV1

Standard Accessories
Quantity

Standard Accessories
1

Standard Accessories
8

Standard Accessories
6

Standard Accessories

Washer fixing plate

Quantity

Standard Accessories

Insulation for fitting

Quantity

Standard Accessories

Sealing Pads

Quantity

Standard Accessories

Elbow

Quantity

Standard Accessories

Paper pattern for installation

Quantity

Standard Accessories

Blocking pad

Quantity

Standard Accessories

Retainer for blocking pad

Quantity

Standard Accessories

Center retainer for blocking pad

Quantity

Standard Accessories

Installation and operation manual

Quantity

2-2 ELECTRICAL SPECIFICATIONS

FXUQ71MV1

FXUQ100MV1

FXUQ125MV1

Name

V1

Phase

2-3

Clamps

Quantity

Current

Washer for locking hanger

Quantity

Power Supply

Metal clamp for drain hose

Quantity

FXUQ125MV1

Drain hose

Frequency

Hz

Voltage

Full load amps (FLA)

50

50

50

220-240
0.60

1.00

1.00

Safety device settings

FXUQ-MV1
FAN MOTOR THERMAL PROTECTOR

71
C

100
OFF: 1305

125
4D013856D

VRVII Systems Indoor Units

Indoor Units 4-WAY BLOW CEILING SUSPENDED UNIT FXUQ-MV1

Options
FXUQ-MV1
SEALING MEMBER OF AIR DISCHARGE OUTLET
DECORATION PANEL FOR AIR DISCHARGE

71
KDBHJ49F80
KDBTJ49F80

VERTICAL FLAP KIT


REPLACEMENT LONG-LIFE FILTER
L CONNECTION PIPING KIT

KDGJ49F80

100

125
KDBHJ49F140
KDBTJ49F140
KDGJ49F140

KAFJ495F140
KHFP49M63

KHFP49M140
3D045452

Control systems

Individual control systems


WIRED REMOTE CONTROL
INFRARED REMOTE CONTROL

Heat pump
Cooling only

BRC1D527
BRC7C528W
BRC7C529W

Centralised control systems


CENTRALISED REMOTE CONTROL

DCS302C51

UNIFIED ON/OFF CONTROL

DCS301B51

SCHEDULE TIMER

DST301B51

3
Others
GROUP CONTROL ADAPTOR 1
INTERFACE ADAPTER FOR SKY AIR SERIES

KRP4A53
DTA102A52

INSTALLATION BOX FOR ADAPTER PCB


REMOTE SENSOR

KRP1B97
KRCS01-1

CONNECTOR FOR FORCED ON, FORCED OFF

EKF0F0
3D045452

NOTE

Installation box for adapter PCB (KRP1B97) is necessary.

VRVII Systems Indoor Units

Indoor Units 4-WAY BLOW CEILING SUSPENDED UNIT FXUQ-MV1

Capacity tables

5-1

Cooling capacity tables

FXUQ-MV1
TC: Total capacity;kW SHC: Sensible capacity;kW
Unit size

Nominal
capacity

71

8.0

100

11.2

125

14.0

Outdoor
air temp.
CDB
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0
10.0
12.0
14.0
16.0
18.0
20.0
21.0
23.0
25.0
27.0
29.0
31.0
33.0
35.0
37.0
39.0

14.0WB
20.0DB
TC
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
5.4
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5

16.0WB
23.0DB
SHC
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
4.8
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
6.6
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0

TC
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3
11.3

18.0WB
26.0DB
SHC
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
5.2
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
7.1
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0

TC
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
10.5
10.5
10.5
10.5
10.5
10.5
10.5
10.5
10.5
10.5
10.5
10.5
10.5
10.5
10.5
10.5
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1
13.1

SHC
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
5.8
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9
9.9

VRVII Systems Indoor Units

Indoor air temperature


19.0WB
27.0DB
TC
SHC
8.0
6.0
8.0
6.0
8.0
6.0
8.0
6.0
8.0
6.0
8.0
6.0
8.0
6.0
8.0
6.0
8.0
6.0
8.0
6.0
8.0
6.0
8.0
6.0
8.0
6.0
8.0
6.0
8.0
5.9
8.0
6.1
11.2
8.2
11.2
8.2
11.2
8.2
11.2
8.2
11.2
8.2
11.2
8.2
11.2
8.2
11.2
8.2
11.2
8.2
11.2
8.2
11.2
8.2
11.2
8.2
11.2
8.2
11.2
8.2
11.2
8.2
11.2
8.2
14.0
10.4
14.0
10.4
14.0
10.4
14.0
10.4
14.0
10.4
14.0
10.4
14.0
10.4
14.0
10.4
14.0
10.4
14.0
10.4
14.0
10.4
14.0
10.4
14.0
10.4
14.0
10.4
14.0
10.4
14.0
10.4

20.0WB
28.0DB
TC
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.4
8.3
8.1
11.9
11.9
11.9
11.9
11.9
11.9
11.9
11.9
11.9
11.9
11.9
11.9
11.9
11.8
11.6
11.4
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.9
14.8
14.5
14.3

22.0WB
30.0DB
SHC
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
5.9
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.3
8.2
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.6
10.5
10.5
10.2

TC
9.6
9.6
9.6
9.6
9.6
9.6
9.6
9.4
9.3
9.2
9.0
8.9
8.7
8.6
8.5
8.3
13.4
13.4
13.4
13.4
13.4
13.4
13.4
13.2
13.0
12.8
12.6
12.4
12.2
12.1
11.9
11.7
16.8
16.8
16.8
16.8
16.8
16.8
16.8
16.5
16.3
16.1
15.8
15.6
15.3
15.1
14.9
14.6

24.0WB
32.0DB
SHC
6.2
6.2
6.2
6.2
6.2
6.2
6.2
6.2
6.1
6.0
5.9
5.8
5.8
5.7
5.8
5.6
8.4
8.4
8.4
8.4
8.4
8.4
8.4
8.2
8.1
8.0
7.9
7.9
7.8
7.7
7.7
7.6
10.7
10.7
10.7
10.7
10.7
10.7
10.7
10.5
10.4
10.2
10.1
10.0
9.9
9.9
9.8
9.6

TC
10.5
10.4
10.3
10.1
10.0
9.8
9.8
9.6
9.5
9.4
9.2
9.1
8.9
8.8
8.7
8.5
14.7
14.5
14.4
14.2
14.0
13.8
13.7
13.5
13.3
13.1
12.9
12.7
12.5
12.3
12.2
12.0
18.4
18.2
18.0
17.7
17.5
17.2
17.1
16.9
16.6
16.4
16.2
15.9
15.7
15.4
15.2
15.0

SHC
6.3
6.2
6.2
6.1
6.0
5.9
5.9
5.8
5.7
5.7
5.7
5.6
5.6
5.5
5.4
5.4
8.5
8.4
8.3
8.2
8.1
8.0
7.9
7.8
7.7
7.7
7.6
7.6
7.6
7.4
7.3
7.3
10.8
10.7
10.5
10.4
10.2
10.1
10.0
9.9
9.9
9.8
9.7
9.6
9.6
9.4
9.4
9.3

Indoor Units 4-WAY BLOW CEILING SUSPENDED UNIT FXUQ-MV1

Capacity tables

5-2

Heating capacity tables

FXUQ-MV1
Unit Size
71

9.0

100

12.5

125

Outdoor
air temperature

Nominal capacity

14.0

CDB
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0
-19.8
-18.8
-16.7
-14.7
-12.6
-10.5
-9.5
-8.5
-7.0
-5.0
-3.0
0.0
3.0
5.0
7.0
9.0
11.0
13.0
15.0

CWB
-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7
-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7
-20.0
-19.0
-17.0
-15.0
-13.0
-11.0
-10.0
-9.1
-7.6
-5.6
-3.7
-0.7
2.2
4.1
6.0
7.9
9.8
11.8
13.7

16.0
kW
5.3
5.5
5.8
6.1
6.4
6.7
6.9
7.1
7.3
7.6
7.9
8.4
8.9
9.1
9.5
9.8
10.1
10.1
10.1
7.4
7.6
8.0
8.5
8.9
9.4
9.6
9.8
10.1
10.6
11.0
11.6
12.3
12.7
13.1
13.5
14.0
14.1
14.1
8.3
8.5
9.0
9.5
10.0
10.5
10.8
11.0
11.3
11.8
12.3
13.0
13.8
14.2
14.7
15.2
15.6
15.8
15.8

VRVII Systems Indoor Units

18.0
kW
5.3
5.5
5.8
6.1
6.4
6.7
6.9
7.0
7.3
7.6
7.9
8.4
8.8
9.1
9.4
9.6
9.6
9.6
9.6
7.4
7.6
8.0
8.5
8.9
9.3
9.6
9.8
10.1
10.5
11.0
11.6
12.3
12.7
13.1
13.3
13.3
13.3
13.3
8.2
8.5
9.0
9.5
10.0
10.5
10.7
10.9
11.3
11.8
12.3
13.0
13.7
14.2
14.7
14.9
14.9
14.9
14.9

Indoor air temperature CDB


20.0
21.0
kW
kW
5.3
5.3
5.4
5.4
5.8
5.7
6.1
6.1
6.4
6.4
6.7
6.7
6.9
6.9
7.0
7.0
7.3
7.3
7.6
7.6
7.9
7.9
8.3
8.3
8.8
8.7
9.0
8.7
9.0
8.7
9.0
8.7
9.0
8.7
9.0
8.7
9.0
8.7
7.3
7.3
7.6
7.5
8.0
8.0
8.4
8.4
8.9
8.9
9.3
9.3
9.5
9.5
9.7
9.7
10.1
10.1
10.5
10.5
10.9
10.9
11.6
11.6
12.2
12.1
12.5
12.1
12.5
12.1
12.5
12.1
12.5
12.1
12.5
12.1
12.5
12.1
8.2
8.2
8.4
8.4
9.0
8.9
9.5
9.4
10.0
10.0
10.4
10.4
10.7
10.7
10.9
10.9
11.3
11.3
11.8
11.8
12.3
12.2
13.0
13.0
13.7
13.6
14.0
13.6
14.0
13.6
14.0
13.6
14.0
13.6
14.0
13.6
14.0
13.6

22.0
kW
5.3
5.4
5.7
6.1
6.4
6.7
6.9
7.0
7.2
7.5
7.9
8.3
8.4
8.4
8.4
8.4
8.4
8.4
8.4
7.3
7.5
8.0
8.4
8.9
9.3
9.5
9.7
10.1
10.5
10.9
11.6
11.7
11.7
11.7
11.7
11.7
11.7
11.7
8.2
8.4
8.9
9.4
9.9
10.4
10.7
10.9
11.2
11.7
12.2
13.0
13.1
13.1
13.1
13.1
13.1
13.1
13.1

24.0
kW
5.3
5.4
5.7
6.1
6.4
6.7
6.8
7.0
7.2
7.5
7.9
7.9
7.9
7.9
7.9
7.9
7.9
7.9
7.9
7.3
7.5
8.0
8.4
8.8
9.3
9.5
9.7
10.0
10.5
10.9
10.9
10.9
10.9
10.9
10.9
10.9
10.9
10.9
8.2
8.4
8.9
9.4
9.9
10.4
10.6
10.8
11.2
11.7
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2

Indoor Units 4-WAY BLOW CEILING SUSPENDED UNIT FXUQ-MV1

Dimensional drawing
FXUQ71MV1
Drain connection
location for rear
piping

Drain connection
location for upper
piping

1500mm
or more
Required space

1500mm
or more

1500mm
or more
Drain pipe can be raised up to 350mm from the top surface of the product.

1500mm
or more
When closing the discharge grill, the required space is
30mm or more. (Nore3)

790 Suspension position

790 Suspension position

Brand name plate (Note 2)

Nr
1
2
3
4
5
6
7
8
9
10

Suspension bolt
4-M3~M10
Height of suspension bracket

Part name
Liquid pipe connection
GAS pipe connection
Drain pipe connection
Air outlet
Air suction grille
Corner decoration cover
Right pipe/wiring connection
Rear pipe/wiring connection
Pipe through cover
Accessory drain elbow

Description
9.5 Flare connection
15.9 Flare connection
VP20

1000mm or more (Requierd space)

NOTES

1
2

Location for manufactures label: on bell mouth.


This is where the signal of infrared remote control is received.
Refer to the drawing of wireless remote controller in detail.

When closing the discharge grill (2 or 3 way discharge), direction of


pipe connection will be limited, please refer to Installation manual..

3D013860C

FXUQ100-125MV1
Drain connection
location for rear
piping

Drain connection
location for upper
piping

Drain pipe can be


raised up to 350mm from the top surface of the product.

1500mm
or more

1500mm
or more
When closing the discharge grill, the required space is
30mm or more. (Nore3)

790 Suspension position

790 Suspension position

Brand name plate (Note 2)

1500mm
or more
Required space
1500mm
or more

Nr
1
2
3
4
5
6
7
8
9
10

Suspension bolt
4-M3~M10
Height of suspension bracket

1000mm or more (Requierd space)

Part name
Liquid pipe connection
GAS pipe connection
Drain pipe connection
Air outlet
Air suction grille
Corner decoration cover
Right pipe/wiring connection
Rear pipe/wiring connection
Pipe through cover
Accessory drain elbow

Description
9.5 Flare connection
15.9 Flare connection
VP20

NOTES

1
2

Location for manufactures label: on bell mouth.


This is where the signal of infrared remote control is received.
Refer to the drawing of wireless remote controller in detail.

When closing the discharge grill (2 or 3 way discharge), direction of


pipe connection will be limited, please refer to Installation manual..

3D044898A

VRVII Systems Indoor Units

Indoor Units 4-WAY BLOW CEILING SUSPENDED UNIT FXUQ-MV1

Piping diagram

FXUQ-MV1

Indoor heat exchanger

Field piping A C1220T -0

To outdoor unit

Field piping B C1220T -0

Indoor unit

Piping connection diameters


Model
FXUQ70,100,125MV1

A
9.5

B
15.9

4D037995B

VRVII Systems Indoor Units

Indoor Units 4-WAY BLOW CEILING SUSPENDED UNIT FXUQ-MV1

Wiring diagram

FXUQ-MV1

Power Supply
50
~
220-240V

Note 1
BEV unit

(Note 3)
Receiver/display unit
Indoor unit

Wired remote
control

Control box

Indoor unit
A1P
A2P
C1
HAP
HBP
M1S
M1F
M1P
Q1M
R1T
R2T
RYA

Printed circuit board


Printed circuit board (Transformer 220~240V/16V)
Capacitor (M1F)
Light emitting.diode
(Service monitor-green)
Light emitting.diode
(Service monitor-green)
Motor (Swing flap)
Motor (Indoor Fan)
Motor (Drain pump)
Thermo switch (M1F embedded)
Thermistor (Air)
Thermistor (Coil)
Magnetic relay (M1A)

RYP
S1Q
S1L
SS1
V1TR
X1M
X2M
RC
TC

Magnetic relay (M1P)


Limit switch (Swing flap)
Float switch
Selector switch (Emergency)
Phase control circuit
Terminal strip
Terminal strip
Signal receiver
Signal transmission Circuit

Connector for optional parts


X24A
Connector (Infrafed remote control)
X30A
Connector (Interface adapter for sky air series)
X35A
Connector (Group control adapter)

Wired remote control


R1T
SS1

: Terminal
: Connector
: Field wiring

Receiver/Display unit (Attached to wireless remote control


A3P
Printed circuit board
A4P
Printed circuit board
BS1
Push button (ON/OFF)
H1P
Light emitting diode (ON-Red)
H2P
Light emitting diode (Timer-Green)
H3P
Light emitting diode (Filter sign-Red)
H4P
Light emitting diode (Defrost-Orange)
SS1
Selector switch (Main/Sub)
SS2
Selector switch (Wireless address set)

COLORS : RED : Red


WHT : White
GRN : Green

BLK : Black
YLW : Yellow
BLU : Bleu

NOTES

The BEV unit shows an outline, please refer to a wiring diagram of BEV unit pasting in detail.

2
3
4

In case using central remote control, connect it to the unit in accordance with the attached installation manual.
X24A is connected when the infrared remote control kit is being used.
Remote control model varies according to the combination system, confirm engineering materials and catalogs, etc. before connecting.

Confirm the method of setting the selector switch (SS1, SS2) of wired remote control and infrared remote control by installation manual and engineering data, etc.

3D044973

10

VRVII Systems Indoor Units

Indoor Units 4-WAY BLOW CEILING SUSPENDED UNIT FXUQ-MV1

Sound data

9-1

Sound pressure spectrum

3
4D014037C

Octave band sound pressure level dB (0 dB=0.0002 bar)

FXUQ71MV1

HI (230V)

Low (230V)

Approximate
threshold hearing for
continuous noise
Octave band center frequency (Hz)
NOTES

Over all (dB):


230 V

Scale

HI
40

A
2

Lox
35

Power level (dB):


230 V
HI
56

3
4

Lox
51

Measuring place: Anechoic chamber


Operating conditions:
Power source 230V 50 Hz
Cooling: Return air temperature: 27CDB, 19CWB
Outdoor temperature: 35CDB, 24CWB
Heating: Return air temperature: 20CDB, 15CWB
Outdoor temperature: 7CDB, 6CWB
Directions discharge:

Location of mictrophone:

Operation noise differs with operation and ambient conditions.

230V

VRVII Systems Indoor Units

11

Indoor Units 4-WAY BLOW CEILING SUSPENDED UNIT FXUQ-MV1

Sound data

9-1

Sound pressure spectrum


4D0140038C

FXUQ100MV1

HI (230V)

Low (230V)

Approximate
threshold hearing for
continuous noise
Octave band center frequency (Hz)
NOTES

Over all (dB):


50 Hz 240 V

Scale

HI
43

A
2

Lox
38

Power level (dB):


230 V
HI
59

3
4

Lox
54

Measuring place: Anechoic chamber


Operating conditions:
Power source 230V 50 Hz
Cooling: Return air temperature: 27CDB, 19CWB
Outdoor temperature: 35CDB, 24CWB
Heating: Return air temperature: 20CDB, 15CWB
Outdoor temperature: 7CDB, 6CWB
Directions discharge:

Location of mictrophone:

Operation noise differs with operation and ambient conditions.

230V

12

VRVII Systems Indoor Units

Indoor Units 4-WAY BLOW CEILING SUSPENDED UNIT FXUQ-MV1

Sound data

9-1

Sound pressure spectrum

3
4D0140039C

Octave band sound pressure level dB (0 dB=0.0002 bar)

FXUQ125MV1

HI (230V)

Low (230V)

Approximate
threshold hearing for
continuous noise
Octave band center frequency (Hz)
NOTES

Over all (dB):


230 V

Scale

HI
44

A
2

Lox
39

Power level (dB):


230 V
HI
60

3
4

Lox
55

Measuring place: Anechoic chamber


Operating conditions:
Power source 230V 50 Hz
Cooling: Return air temperature: 27CDB, 19CWB
Outdoor temperature: 35CDB, 24CWB
Heating: Return air temperature: 20CDB, 15CWB
Outdoor temperature: 7CDB, 6CWB
Directions discharge:

Location of mictrophone:

Operation noise differs with operation and ambient conditions.

230V

VRVII Systems Indoor Units

13

Indoor Units 4-WAY BLOW CEILING SUSPENDED UNIT FXUQ-MV1

10

Air flow pattern

10 - 1 Air flow pattern - Cooling


FXUQ71MV1

Cooling - air velocity distribution


4-way discharge, air flow direction: horizontal

1.75m/s
2.0m/s

2.7m
1.5m/s
1.25m/s
1.0m/s

2m
0.75m/s
1m
0.5m/s

10
0m

Cooling - air temperature distribution


4-way discharge, air flow direction: horizontal

2.7m

2m

1m

0m

4D028396B

14

VRVII Systems Indoor Units

Indoor Units 4-WAY BLOW CEILING SUSPENDED UNIT FXUQ-MV1

10

Air flow pattern

10 - 1 Air flow pattern - Cooling

FXUQ100MV1

Cooling - air velocity distribution


4-way discharge, air flow direction: horizontal

2.0m/s

2.7m
1.75m/s

1.5m/s
2m

1.25m/s
1.0m/s
0.75m/s

1m

0.5m/s
0m

10

Cooling - air temperature distribution


4-way discharge, air flow direction: horizontal

2.7m

2m

1m

0m

4D028397B

VRVII Systems Indoor Units

15

Indoor Units 4-WAY BLOW CEILING SUSPENDED UNIT FXUQ-MV1

10

Air flow pattern

10 - 1 Air flow pattern - Cooling


FXUQ125MV1

Cooling - air velocity distribution


4-way discharge, air flow direction: horizontal

2.0m/s

2.7m
1.75m/s

1.5m/s
2m

1.25m/s
1.0m/s
0.75m/s

1m

0.5m/s

10
0m

Cooling - air temperature distribution


4-way discharge, air flow direction: horizontal

2.7m

2m

1m

0m

4D028398B

16

VRVII Systems Indoor Units

Indoor Units 4-WAY BLOW CEILING SUSPENDED UNIT FXUQ-MV1

10

Air flow pattern

10 - 2 Air flow pattern - Heating

FXUQ71MV1

Heating - air velocity distribution


4-way discharge, air flow direction: down

2.7m
2.0m/s
2m

1.75m/s
1.5m/s
1.25m/s
1.0m/s

1m
0.75m/s
0.5m/s

10
0m

Heating - air temperature distibution


4-way discharge, air flow direction: down

2.7m

2m

1m

0m

4D013863C

VRVII Systems Indoor Units

17

Indoor Units 4-WAY BLOW CEILING SUSPENDED UNIT FXUQ-MV1

10

Air flow pattern

10 - 2 Air flow pattern - Heating


FXUQ100MV1

Heating - air velocity distribution


4-way discharge, air flow direction: down

2.7m

2m
2.0m/s
1.75m/s
1.5m/s
1.25m/s
1.0m/s
0.75m/s
0.5m/s

10

1m

0m

Heating - air temperature distribution


4-way discharge, air flow direction: down

2.7m

2m

1m

0m

4D014054C

18

VRVII Systems Indoor Units

Indoor Units 4-WAY BLOW CEILING SUSPENDED UNIT FXUQ-MV1

10

Air flow pattern

10 - 2 Air flow pattern - Heating

FXUQ125MV1

Heating - air velocity distribution


4-way discharge, air flow direction: down

2.7m

2m
2.0m/s
1.75m/s
1m

1.5m/s
1.25m/s
1.0m/s
0.75m/s

10

0.5m/s
0m

Heating - air temperature distribution


4-way discharge, air flow direction: down

2.7m

2m

1m

0m

4D014055C

VRVII Systems Indoor Units

19

Indoor Units JUNCTION BOX BEVQ-MVE

V ir M otI - ocI Q dnV nuRE 11


IJVB

Junction box - BEVQ-MVE

11 - 1 Specifications
11 - 1 - 1 Technical Specifications

BEVQ71MVE

BEVQ100MVE

BEVQ125MVE

Power input
(Nominal)

Cooling

kW

0.189

0.298

0.298

Heating

kW

0.169

0.278

0.278

Casing

Material

Dimensions

Unit

Galvanised steel plate


Height

mm

100

100

100

Width

mm

350

350

350

Depth

mm

225

225

225

Sound absorbing thermal insulation material


Weight

Machine Weight

Indoor Units

Liquid (OD)

kg

Liquid (OD)

Standard
Accessories

mm

9.5

Type
mm

15.9

Type
mm

9.5

Type
Diameter

mm

15.9

Item
Quantity

15.9

9.5

9.5

15.9

15.9

Gas piping connections


1

Insulation for fitting

Quantity

Item

Sealing material

Quantity

Item

Clamps

Quantity

11 - 1 - 2 Electrical Specifications

BEVQ71MVE

BEVQ100MVE

BEVQ125MVE

Name

VE

Phase

Total circuit

15.9

Installation manual

Item

Voltage range

9.5

Flare connection

Quantity

Power Supply

9.5

Flare connection

Item

11

3.5

Flare connection

Diameter
Suction gas
(OD)

3.0
Flare connection

Diameter
Outdoor Unit

3.0

Type
Diameter

Gas

Flame and heat resistant foamed polyetherene

Frequency

Hz

50/60
220-240

Voltage

Minimum

-10%

Maximum

+10%

Minimum circuit amps


(MCA)

0.8

1.3

1.3

Maximum fuse amps (MFA) A

15

15

15

NOTES
1

Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed range limits.

Maximum allowable voltage range variation between phases is 2%.

20

MCA/MFA
MCA=1.25 X FLA

MFA is smaller than or equal to 4 x FLA

Next lower standard fuse rating minimum 15A

Select wire size based on MCA

Instead of a fuse, use a circuit breaker

VRVII Systems Indoor Units

Indoor Units JUNCTION BOX BEVQ-MVE

11

Junction box - BEVQ-MVE

11 - 2 Dimensional drawing & centre of gravity

11 - 2 - 1 Dimensional drawing - Wall mounted installation


BEVQ-MVE

200 or more
(Servicing space)

100 or more
(Servicing space)

Nr
1
2
3
4
5
6
7

(165.5)

(Suspension bolt pitch)

500 or more
(Servicing space)

200 or more
(Servicing space)

4-M4 Mounting

Note 2
(Servicing space)

NOTES

1
INSTALLATION FIGURE
(When installing the unit on wall)

Part name
Description
Liquid pipe connection port
9.5 mm Flare connection
Gas pipe connection port
15.9 mm Flare connection
Electric parts box
Suspension bolt
Wire connection port (Indoor unit conncection)
Wire connection port (Power supply Ground)
Wire connection port (Transmission (VRV) Gas pipe thermistor)

Be sure to install wire connection port to be sure to become


downward.
Be sure to secure the space which can be the thightening work of
the flare nut.

11

3D045389

VRVII Systems Indoor Units

21

Indoor Units JUNCTION BOX BEVQ-MVE

11

Junction box - BEVQ-MVE

11 - 2 Dimensional drawing & centre of gravity


11 - 2 - 2 Dimensional drawing - Ceiling suspended installation

Nr
1
2
3
4
5
6
7

(165.5)

(Suspension bolt pitch)

BEVQ-MVE

Inspection hatch

Part name
Description
Liquid pipe connection port
9.5 mm Flare connection
Gas pipe connection port
15.9 mm Flare connection
Electric parts box
Suspension bolt
Wire connection port (Indoor unit conncection)
Wire connection port (Power supply Ground)
Wire connection port (Transmission (VRV) Gas pipe thermistor)

(Suspension bolt pitch)


Note 2
(Servicing space)

NOTES
Note 3

100 or more
(Servicing space)

200 or more
(Servicing space)

200 or more
(Servicing space)

INSTALLATION FIGURE
(When hanging the unit from the ceiling)

11

Be sure to install wire connection port to be sure to become


downward.

Be sure to secure the space which can be the thightening work of


the flare nut.
Be sure to secure the space of 400 mm or more when you cannot
install the inspection hatch right under the unit.

3D045390

22

VRVII Systems Indoor Units

Indoor Units JUNCTION BOX BEVQ-MVE

11

Junction box - BEVQ-MVE

11 - 3 Dimensional drawing & centre of gravity

11 - 3 - 1 Centre of gravity
BEVQ-MVE

11

3D030851B

VRVII Systems Indoor Units

23

Indoor Units JUNCTION BOX BEVQ-MVE

11

Junction box - BEVQ-MVE

11 - 4 Piping diagram
BEVQ-MVE

11

Liquid piping
connection port

Filter

Electronic
expansion valve

Gas piping
connection port

Filter

Liquid piping
connection port

Gas piping
connection port

4D034127A

24

VRVII Systems Indoor Units

Indoor Units JUNCTION BOX BEVQ-MVE

11

Junction box - BEVQ-MVE

11 - 5 Wiring diagram

BEVQ-MVE

Power Supply
50
60
~
~
220-240V 220V

To indoor unit

Note 4
To interface adaptor for sky
air series of indoor unit.

Control box

11

To outdoor unit

A1P
A2P
F1U
HAP

Printed circuit board Assy


Power supply printed circuit board Assy (220-240V/16V)
Fuse (, 10A/250V)
Light emitting.diode
(Service monitor-green)
Thermistor (Gas)

R3T

: Terminal
: Connector
: Field wiring

SS1
X1M
X2M
Y1E
Z1C ~ Z3C / Z4F

Selector Switc(M/S)
Terminal strip (Power)
Terminal strip (Transmission)
Electronic expansion valve
Noise filter

COLORS : BLU : Blue


WHT : White

RED : Red
BLK : Black

NOTES

1
2
3

This wiring diagram only shows the BEV unit. See the wiring diagrams and installation manuals for the wiring and settings for the indoor, outdoor, and BS units.
See the indoor units wiring diagram when installing optional parts for the indoor unit.
Only one indoor unit may be connected to the BEV unit. See the indoor unit's wiring diagram when connecting the remote control.

4
5

Always use the sky air connection adapter for the indoor unit when using a central control unit. Refer to the manual attached the unit when connecting.
Cool/Heat changeover of indoor units connected to BEV unit cannot be carried out unless they are connected to BS unit.
In cas of a system with BEV unit only, Cool/Heat selector is required.
Set the SS1 tot M only for the BEV unit connected to the indoor unit which is to have Cool/Heat switching capability, when connecting the BS unit.
The M/S on the SS1 stands for Main/Sub.
This is set to S when shipped from the factory.

Connect the attached thermistor to the R3T.

3D044901

VRVII Systems Indoor Units

25

Indoor Units JUNCTION BOX BEVQ-MVE

11

26

VRVII Systems Indoor Units

Systems

ISO14001 assures an effective environmental


management system in order to help protect
humanhealthand the environment from the potential
impact of our activities, products and services and to
assist in maintaining and improving the quality of
theenvironment.

Daikin Europe N.V. is approved by LRQA for its Quality


Management System in accordance with the ISO9001
standard. ISO9001 pertains to quality assurance regarding
design, development, manufacturing as well as to services
related to the product.

Daikin units comply with the European


regulations that guarantee the safety of
the product.
VRV products are not within the scope of
the Eurovent certification programme.
Daikin equipment is designed for comfort
applications. For use in other applications,
please contact your local Daikin
representative.

Zandvoordestraat 300
B-8400 Ostend - Belgium
www.daikineurope.com

EEDE05-2 03/2005
Prepared in Belgium by Lannoo

Specifications are subject to change without prior notice

Potrebbero piacerti anche