1. Configure the assigned slot/port/VLAN on the Ethernet Config of both sites, Save selected
to device.
2. Create a dynamic tunnel.
Needed: Slot and port of source and sink site

IP config
Tunnel Config
Signaling: Dynamic
Protection: Dynamic LSP 1:1 Protection

CONFIDETIAL

Page 2 of 6
SUBJECT

E-Line Service Configuration MOP


REFERENCE NUMBER

REVISION

PREPARED BY:

DATE

V 1.0

Gilbert T. Lacanlale

April 29, 2015

Click Source LSR and Sink LSR


Check enable BFD

Check Strict Routing


Click the left circle/button to create the forward main route(click the foc line then the next
hop site until it reached its destination) then the right button to create the reverse main
route.

CONFIDETIAL

Page 3 of 6
SUBJECT

E-Line Service Configuration MOP


REFERENCE NUMBER

REVISION

PREPARED BY:

DATE

V 1.0

Gilbert T. Lacanlale

April 29, 2015

CONFIDETIAL

Page 4 of 6
SUBJECT

E-Line Service Configuration MOP


REFERENCE NUMBER

REVISION

PREPARED BY:

DATE

V 1.0

Gilbert T. Lacanlale

April 29, 2015

Configure the protection route. Click strict routing, click left button to create forward
protection route and right button to create reverse protection route. Select 10ms on path 1
and 2

Under Path 1/Path 2 BFD Properties, Select 10ms for the minimum transmit and received
time.

CONFIDETIAL

Page 5 of 6
SUBJECT

E-Line Service Configuration MOP


REFERENCE NUMBER

REVISION

PREPARED BY:

DATE

V 1.0

Gilbert T. Lacanlale

April 29, 2015

Note: Do not forget to add Management IP on each LDP protocol mutually on each NE.
3. Create the VC.
If there are four VLANs, create four VC on the existing or created tunnel.
Right Click on the Tunnel, Choose Add IPRAN VC Circuit.
Details:
Signaling: Dynamic
Click Next
Batch Creation Settings
Lot Size: (Depends on the numbers of E-Line service which corresponds to the equal
number of VC that must be created)
Click Completed
4. Create the Eline service
Go to Service Configuration >> IP Config >> L2VPN Config (L)
Service Name: Site ID Slotand PortNumber VLAN VLAN Number
Example: 3835 s2p11 VLAN 580
Next
Select the site and ports
Source NE: Click the source site
Source Port: click the slot,port and vlan id
Sink NE: click the sink site
Sink Port:click the slot
Next
Choose a VC
UNI must be VPWS on both sites
Completed
5. Deliver the protection pair
6. Deliver the cross connect of the tunnel
7. Deliver the cross connect of the service

8. To check the service status via Secure CRT. Run these commands.

CONFIDETIAL

Page 6 of 6
SUBJECT

E-Line Service Configuration MOP


REFERENCE NUMBER

REVISION

PREPARED BY:

DATE

V 1.0

Gilbert T. Lacanlale

April 29, 2015

Access the Site by opening a connection via its Site NE IP.


telnet 127.1 2650
password: fiberhome
enable
#show ldp session -> must have uptime
#show mpls vc-table ->must have uptime
#sh run interface GE0/3/7
#sh run interface GE0/3/7.580
#sh running-config rsvp-path >> to check your route
9. Creating a static tunnel.
Need to plan PW labels, 2 for tunnel and 2 for VC
Example: 1159-1160 for tunnel and 1161-1162 for VC
Service configuration > IP Config > Tunnel Config
Signaling: Static
Protection: depends on plan
Tick Enable BFD
Insert your Label.