isoelectric
ENEL S.p.A. (Italian Electric Company)
FERROVIE DELLO STATO S.p.A. (Italian Railways Company)
O.N.E. (National Office of the Electricity of Morocco)
TRANSELEC (Chilean Electric Company)
ENDESA (Spanish Electric Company)
TRINIDAD and TOBAGO ELECTRICITY CO.
FIJI ELECTRIC COMPANY CO.
U.T.E. (Uruguayan Electric Company )
SAESA (Chilean Electric Company)
RENFE (Spanish Railways)
S.N.C.B. (Belgian Railways)
TEIAS (Turkish Electric Company)
R.A.T.P. (Underground of Paris)
CEMIG (Brazilian Electric Company )
LUZ y FUERZA (Mexican Electric Company)
EDELNOR (Peruvian Electric Company )
P.P.C. (Grecian Electric Company)
COELBA (Brazilian Electric Company )
CONECTIV (Delaware - USA Electric Company)
UNION FENOSA (Spanish Electric Company)
TANESCO (Tanzanian Electric Company)
MANUFACTURERS of ELECTRIC EQUIPMENTS
Note: All the above references can be proved by documents. The above list includes
the firsts insulators installed in 1985 and it is revised to JANUARY 2011,
more than 26 years !!.
isoelectric - Italy
3
09-9
SILISOL
COMPOSITE INSULATORS IN SILICONE RUBBER
SILISOL, the composite SILICONE insulator, was born through a twenty years
experience of the isoelectric, which is the market leader in epoxy resin insulators, for
indoor use and in cycloaliphatic resin insulators, for outdoor use.
isoelectric - Italy
4
09-9
isoelectric - Italy
5
09-9
Taking this phenomenon into account isoelectric has applied an external housing of
suitable shape, made of a material with excellent dielectric features, a material that is
totally resistant to chemical attack and atmospheric agents.
THE SILICONE
SILIC 1.75
The adherence of the SILICONE housing to the ECR fibreglass rod is achieved by
particular methods that allow very high shearing values. By these methods, at an
interface level with the housing in SILICONE, a one piece injection moulding
(monolithic) construction has been obtained from one end fitting to the other end
fitting.
The SILICONE mixture is made of a pure 100% silicon polymer and filler. This
mixture is characterised by a great resistance to the superficial electrical discharges,
tracking, by a surface with permanent properties of hydrophobicity as well as by a
great insulating property under high pollution.
Shapes, dimensions and materials can agree every time, according to the customers
need too.
isoelectric - Italy
6
04-2
isoelectric
COMPOSITE INSULATORS ARE PRODUCED ACCORDING TO SAME OF THE
FOLLOWING STANDARDS
STANDARD
IEC 61109
Emend. 1
IEC 61952
IEC 61466-1
IEC 61466-2
Ed. 1.1 / 2002
IEC 60707
ANSI C29.11
AS 4435.4
I.E. TE 127
ASTM E 662
ASTM G 26
CEI 20-37
DIN 57441
IEEE Std 1024
IEC 60060-1
IEC 60071-1
IEC 60120
IEC 60273
IEC 60383
IEC 60471
IEC 60507
IEC 60815
DESCRIPTION
Composite insulators for overhead lines with a nominal voltage
greater than 1000 V.
Composite line post insulators for overhead lines with a nominal
voltage greater than 1000 V.
Composite string insulator unit for overhead lines,
part 1: standard strength classes and end fittings.
Composite string insulator unit for overhead lines,
part 2: dimensional and electrical characteristics
Test for flammability
Composite suspension insulators for overhead transmission lines
with voltages greater than 1000 V.
Composite line post insulators for overhead power lines.
Composite insulators I621 for contact railways lines with 3 kV dc
Test to determine the optical density of the smokes
Ageing test by ultra-violet rays ( UV )
Test to determine the toxicity and corrosion of the smokes
Accelerated ageing test in saline fog
Recommended practice for specifying distribution composite
insulators ( suspension type )
Methods of tests in high voltage
Insulation co-ordination
Dimensions of ball & socket couplings of string insulators units
Dimensions of post insulators for lines with voltages >1000 V
Tests on porcelain and glass insulators for lines >1000 V
Dimensions of the clevis and tongue couplings of string insulators
units
Artificial pollution test on H.V. insulators to be used in a.c. system
Guide for the selection of insulators in respect of polluted
conditions
The above said standards are taken as reference for design, production and testing.
Other standards can be taken into consideration according to the customers needs.
isoelectric - Italy
7
04-2
IEC 61109
Some tests were performed on some composite insulators SILISOL of the
according to the IEC 61109 standard, as follows:
PARAG.
DESCRIPTION
REPORT
5
5.1
5.1.1
5.1.2
5.1.3
5.1.3.1
5.1.3.2
5.1.3.3
5.1.4
5.1.4.1
5.1.4.2
5.1.4.3
5.2
5.2.1
5.2.2
5.2.2.1
5.2.2.2
5.3
5.3.1
5.3.2
5.3.3
5.3.4
5.4
5.4.1
5.4.1.1
5.4.1.2
5.4.1.3
5.4.2
5.4.2.1
5.4.2.2
5.4.2.3
5.5
5.5.1
5.5.2
Design tests
Tests on interfaces and connections of metal fittings
Test specimens and preliminary tests
Dry power frequency voltage test
Pre-stressing
Sudden load release test
Thermal-mechanical test
Water immersion test
Verification test
Visual examination
Steep-front impulse voltage test
Dry power frequency voltage test
Assembled core load-time test
Test specimens
Mechanical load test
Determ. ave. failing load of the core of the assem. ins.
Control strength-time curve slope of the insulator
Test of housing : tracking and erosion test
Test specimens duration of 1.000 & 5.000 hours
Test procedure
Test conditions
Evaluation of the test
Test for the core material
Dye penetration test
Test specimens
Performance of the test
Acceptance criterion
Water diffusion test
Test specimens
Pre-stressing
Voltage test
Flammability test
Test procedure
Evaluation of the test
6
6.1
6.2
6.4
Type tests
Dry lighting impulse withstand voltage test
Wet power - frequency test
Mechanical load-time test and test of the tightness of ....
isoelectric - Italy
8
isoelectric
04-2
TESTS
REPORT
OF
RECOGNIZED
LABORATORY
ARE
AVAILABLE
IN OUR
FIRM
Internal tests at
isoelectric
ANSI C29.11
The isoelectric composite insulators SILISOL performed some tests were
comparable to the standard ANSI C29.11 as follows :
PARAG.
7
7.1
7.1.1
7.1.2
7.1.3
7.1.4
7.1.5
7.1.6
7.1.6.1
7.1.6.2
7.1.6.3
7.2
7.2.1
7.2.2
7.2.3
7.3
7.3.1
7.3.2
7.3.3
7.3.4
7.4
7.4.1
7.4.1.1
7.4.1.2
7.4.1.3
7.4.2
7.4.2.1
7.4.2.2
7.4.2.3
7.4.2.4
8
8.1
8.2
9.
DESCRIPTION
REPORT
Prototype tests
Test on interfaces and connection of end fittings
Test specimens and preliminary test
Dry power frequency voltage test
Sudden load release test
Thermal-mechanical test
Water penetration test
Verification test
Visual examination
Steep front impulse voltage test
Dry power frequency voltage test
Core time-load test
Test specimens
Test to determine the aver. failing load of the core
Control of the load-time slope of the insulators
Housing tracking and erosion test
Test specimens duration of 5000 hours
Test chamber
Test conditions
Evaluation of the test
Core material test
Dye penetration test
Test specimens
Performance of the test
Evaluation of the test
Water diffusion test
Test specimens
Pre-stressing
Voltage test
Acceptance criterion
Design test
Lighting critical - impulse flashover test
Wet power frequency test
All acceptance tests
isoelectric - Italy
9
04-2
TESTS
REPORT
OF
RECOGNIZED
LABORATORY
ARE
AVAILABLE
IN OUR
FIRM
Internal tests at
isoelectric
IEC 61952
Some tests were performed on some composite insulators SILISOL of the
isoelectric according to the IEC 61952 standard, as follows:
PARAG.
DESCRIPTION
6
6.1
6.2
6.2.1
6.2.2
6.2.2.1
6.2.2.2
6.2.3
6.2.3.1
6.2.3.2
6.2.3.3
6.3
6.3.1
6.3.2
6.4
6.4.1
6.4.2
6.4.3
6.4.3.1 a
6.4.3.1 b
6.4.4
6.5
6.5.1
6.5.1.1
6.5.1.2
6.5.2
6.5.2.1
6.5.2.2
6.5.2.3
7
7.1
7.2
7.2.1
7.2.2
7.2.3
7.2.4
7.3
7.3.1
8
Design tests
General
Tests on interfaces and connections of end fittings
Test specimens
Pre-stressing
Thermal-mechanical pre-stressing
Water immersion test
Verification tests
Visual examination
Steep-front impulse voltage test
Dry power frequency voltage test
Assembled core load-time tests
Test for verif. the Maximum Design Cantilever Load MDCL
Tensile load test
Test of sheds and housing material
Hardness test
Accelerated weathering test
Tracking and erosion test
Test specimens duration of 1000 hours
Test specimens duration of 5000 hours annex C
Flammability test acc. to IEC 60707
Test for the core material
Dye penetration test
Test procedure
Acceptance criteria
Water diffusion test
Test specimens
Pre-stressing
Voltage test
Type tests
Verification of dimensions
Electrical tests
Mounting arrangements
Dry lighting impulse withstand voltage test
Wet power - frequency test
Wet switching impulse withstand voltage test only >300 kV
Mechanical test
Cantilever failing load test
Sample test
isoelectric - Italy
10
REPORT
04-2
TESTS
REPORT
OF
RECOGNIZED
LABORATORY
ARE
AVAILABLE
IN OUR
FIRM
Internal tests at
isoelectric
isoelectric, however, has performed tests and got homologations all over the world.
isoelectric - Italy
11
04-2
isoelectric - Italy
12
04-2
isoelectric - Italy
13
04-2
CONCLUSIONS
Composite insulators SILISOL in SILICONE SILIC 1.75 of the isoelectric
have been installing for a long time, namely since June 1985, in many Countries both
on MV and HV lines.
The insulators installed are divided as follows:
www.isoelectric.it
info@isoelectric.it
isoelectric - Italy
14
04-2
Type ISI-CAN
isoelectric - Italy
15
04-2
TYPE
Code
BALL
B
SOCKET
70 kN
120 kN
160 kN
210 kN
Size 16
Size 16
Size 20
Size 20
IEC 60120
IEC 60120
IEC 60120
IEC 60120
Size 16
Size 16
Size 20
Size 20
IEC 60120
IEC 60120
IEC 60120
IEC 60120
TONGUE
A= 14.0
B= 20.0
C= 17.5
A= 16
B= 27
C= 24
A= 16
B= 27
C= 24
Size 22N
A= 22
B= 26
C= 24
Size 22N
A= 18.0
B= 8.00
C= 34.8
D= 17.5
A= 23.0
B= 11.5
C= 38.0
D= 20.0
A= 23.0
B= 11.5
C= 38.0
D= 20.0
A= 26.0
B= 15.0
C= 43.0
D= 22.0
Size 17
Size 24
Size 24
Size 25
A= 44
B= 20
C= 31
D= 45
E= 12
A= 62
B= 26
C= 52
D= 70
E= 18
A= 62
B= 26
C= 52
D= 70
E= 18
A= 70
B= 26
C= 52
D= 74
E= 22
YCLEVIS
Size 16
Size 19
Size 22
Size 22
H= 40
H= 40
H= 40
H= 40
EYE
isoelectric - Italy
16
06-10
Line Voltage
Catalogue
kV
Code
10 12 15 25 ISI-CIN-A4+3-70CT
n of
Sheds
A
n (1)
Length
L
5
mm
Leakage
distance
Dry arc
distance
mm
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
4+3
325
440
175
85
75
135
150
1,5
Line Voltage
Catalogue
kV
Code
10 12 15 25 ISI-LEN-A3+2-70TT
n of
Sheds
A
n (1)
Length
L
5
mm
Leakage
distance
Dry arc
distance
mm
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
3+2
395
630
260
85
80
170
180
1,9
isoelectric - Italy
17
04-2
Catalogue
kV
Code
10 12 15 25
ISI-MIG-A5-70CT
n of
Sheds
A
n (1)
Length
L
10
mm
Leakage
distance
Dry arc
distance
mm
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
3+2
292
590
240
105
75
135
150
1,5
Catalogue
kV
Code
10 12 15 25 ISI-TWE-A4+3-70TT
n of
Sheds
A
n (1)
Length
L
10
mm
Leakage
distance
Dry arc
distance
mm
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
4+3
395
900
330
110
100
180
200
1,9
isoelectric - Italy
18
04-2
Selection Guide
(Line Voltage, kV)
12
17
24
36
n of
Sheds
Length
L
Leakage
distance
Dry arc
distance
Code ()
A
n (1)
5
mm
mm
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
ISI-SLY-*
ISI-SLY-*
ISI-SLY-*
ISI-SLY-*
ISI-SLY-*
ISI-SLY-*
ISI-SLY-*
ISI-SLY-*
2
3
4
5
6
7
8
9
245
285
325
365
405
445
485
525
200
305
410
515
620
725
830
935
75
115
155
195
235
275
315
355
65
75
85
95
110
125
140
150
55
65
75
85
100
110
120
140
105
120
135
155
185
210
235
260
120
135
150
185
215
240
270
290
2,0
2,2
2,4
2,6
2,7
2,9
3,0
3,2
Catalogue
withstand 50-60 Hz
Lightning impul.
withstand 1,2/50
Weight
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use
( see page 19 ) and refer to the following table :
Ground
fitting
CLEVIS
SOCKET
EYE
EYE
EYE
CLEVIS
SOCKET
Y- CLEVIS
Y- CLEVIS
Line
fitting
TONGUE
BALL
EYE
BALL
TONGUE
BALL
EYE
TONGUE
EYE
Code
(2)
CT
SB
EE
EB
ET
CB
SE
YT
YE
Length
change (L)
0
+45
+90
+60
+45
+15
+70
+45
+90
isoelectric - Italy
19
06-10
Selection Guide
(Line Voltage, kV)
12
17
24
36
Catalogue
Code ()
ISI-TIK-*
ISI-TIK-*
ISI-TIK-*
ISI-TIK-*
ISI-TIK-*
ISI-TIK-*
ISI-TIK-*
ISI-TIK-*
n of
Sheds
A
n (1)
Length
L
10
mm
Leakage
distance
mm
2
3
4
5
6
7
8
9
305
345
385
425
465
505
545
585
260
380
500
620
740
860
980
1100
Dry arc
distance
Weight
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
95
135
175
215
255
295
335
375
65
75
85
95
110
120
140
155
55
65
75
85
100
110
120
135
100
125
160
180
200
220
240
260
105
135
165
195
230
260
285
315
2,0
2,2
2,4
2,6
2,7
2,9
3,0
3,2
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use
(see page 19) and refer to the following table :
Ground
fitting
SOCKET
CLEVIS
EYE
EYE
EYE
CLEVIS
SOCKET
Y- CLEVIS
Y- CLEVIS
Line
fitting
BALL
TONGUE
EYE
BALL
TONGUE
BALL
EYE
TONGUE
EYE
Code
(2)
SB
CT
EE
EB
ET
CB
SE
YT
YE
Length
change (L)
0
-40
+55
+20
+5
-25
+30
+5
+50
isoelectric - Italy
20
06-10
Selection Guide
Catalogue
Code ()
17
24
36
45
52
ISI-BE-*
ISI-BE-*
ISI-BE-*
ISI-BE-*
ISI-BE-*
ISI-BE-*
ISI-BE-*
ISI-BE-*
ISI-BE-*
ISI-BE-*
ISI-BE-*
ISI-BE-*
ISI-BE-*
ISI-BE-*
ISI-BE-*
ISI-BE-*
ISI-BE-*
ISI-BE-*
ISI-BE-*
ISI-BE-*
n of
Sheds
A
n (1)
Length
L
10
mm
Leakage
distance
Dry arc
distance
mm
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
290
320
350
380
410
440
470
500
530
560
590
620
650
680
710
740
770
800
830
860
175
250
325
400
475
550
625
700
780
855
930
1005
1080
1160
1235
1310
1385
1460
1535
1610
80
110
140
170
200
230
260
290
320
350
380
410
440
470
500
530
560
590
620
650
40
50
60
70
80
90
100
115
125
135
145
155
170
180
190
200
215
225
235
245
35
45
55
65
75
85
90
100
110
120
130
140
155
165
175
185
200
210
220
230
70
90
100
115
135
150
160
170
190
200
220
235
255
275
290
305
320
345
360
370
80
100
120
160
180
200
210
220
235
250
275
285
305
325
340
355
380
405
420
445
2,0
2,2
2,4
2,6
2,7
2,9
3,0
3,2
3,4
3,5
3,7
3,9
4,0
4,2
4,4
4,5
4,7
4,9
5,0
5,2
Weight
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use
( see page 19 ) and refer to the following table :
Ground
fitting
SOCKET
CLEVIS
EYE
EYE
EYE
CLEVIS
SOCKET
Y- CLEVIS
Y- CLEVIS
Line
fitting
BALL
TONGUE
EYE
BALL
TONGUE
BALL
EYE
TONGUE
EYE
Code
(2)
SB
CT
EE
EB
ET
CB
SE
YT
YE
Length
change (L)
0
-40
+55
+20
+5
-25
+30
+5
+50
isoelectric - Italy
21
04-2
Selection Guide
Catalogue
17
24
36
45
52
Code ()
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
n of
Sheds
A
n (1)
Length
L
10
mm
Leakage
distance
mm
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
295
330
365
400
435
470
505
540
575
610
645
680
715
750
785
820
855
890
925
960
300
440
580
720
865
1005
1150
1290
1430
1575
1715
1860
2000
2140
2285
2425
2570
2710
2850
2995
Dry arc
distance
Weight
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
85
120
155
190
225
260
295
330
365
400
435
470
505
540
575
610
645
680
715
750
60
70
85
100
110
125
140
150
165
175
190
200
215
230
240
255
270
280
295
305
50
60
70
80
95
105
120
130
140
155
165
180
190
200
215
225
240
250
260
275
105
130
150
170
195
215
240
260
280
305
325
350
370
390
415
435
460
480
500
525
130
150
175
200
220
245
265
290
315
335
360
380
405
430
450
475
495
520
545
565
2,0
2,2
2,4
2,6
2,7
2,9
3,0
3,2
3,4
3,5
3,7
3,9
4,0
4,2
4,4
4,5
4,7
4,9
5,0
5,2
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use
(see page 19) and refer to the following table :
Ground
fitting
SOCKET
CLEVIS
EYE
EYE
EYE
CLEVIS
SOCKET
Y- CLEVIS
Y- CLEVIS
Line
fitting
BALL
TONGUE
EYE
BALL
TONGUE
BALL
EYE
TONGUE
EYE
Code
(2)
SB
CT
EE
EB
ET
CB
SE
YT
YE
Length
change (L)
0
-40
+55
+20
+5
-25
+30
+5
+50
isoelectric - Italy
22
04-2
Selection Guide
Catalogue
17
24
36
45
52
Code ()
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
ISI-NL-*
n of
Sheds
A
n (1)
Length
L
10
mm
Leakage
distance
Dry arc
distance
mm
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
385
420
455
490
525
560
595
630
665
700
735
770
805
840
875
910
945
980
1015
1050
300
440
580
720
865
1005
1150
1290
1430
1575
1715
1860
2000
2140
2285
2425
2570
2710
2850
2995
85
120
155
190
225
260
295
330
365
400
435
470
505
540
575
610
645
680
715
750
60
70
85
100
110
125
140
150
165
175
190
200
215
230
240
255
270
280
295
305
50
60
70
80
95
105
120
130
140
155
165
180
190
200
215
225
240
250
260
275
105
130
150
170
195
215
240
260
280
305
325
350
370
390
415
435
460
480
500
525
130
150
175
200
220
245
265
290
315
335
360
380
405
430
450
475
495
520
545
565
2,0
2,2
2,4
2,6
2,7
2,9
3,0
3,2
3,4
3,5
3,7
3,9
4,0
4,2
4,4
4,5
4,7
4,9
5,0
5,2
Weight
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use
(see page 19) and refer to the following table :
Ground
fitting
SOCKET
SOCKET
EYE
EYE
EYE
CLEVIS
CLEVIS
Y- CLEVIS
Y- CLEVIS
Line
fitting
BALL
EYE
EYE
BALL
TONGUE
BALL
TONGUE
TONGUE
EYE
Code
(2)
SB
SE
EE
EB
ET
CB
CT
YT
YE
Length
change (L)
0
+35
+64
+29
+27
-8
-10
+15
+52
isoelectric - Italy
23
04-2
Selection Guide
Catalogue
17
24
36
45
52
Code ()
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
n of
Sheds
A
n (1)
Length
L
10
mm
Leakage
distance
mm
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
305
345
385
425
465
505
545
585
625
665
705
745
785
825
865
905
945
985
1025
1065
255
370
485
600
715
830
945
1060
1175
1290
1405
1520
1635
1800
1915
2030
2150
2265
2380
2520
Dry arc
distance
Weight
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
95
135
175
215
255
295
335
375
415
455
495
535
575
615
655
695
735
775
815
855
65
75
85
100
110
120
135
150
160
175
190
215
230
250
260
280
290
300
315
330
55
60
70
85
100
110
120
130
140
155
165
180
200
220
230
250
260
270
280
300
100
130
160
180
200
220
240
260
280
305
325
340
370
410
450
480
500
520
540
570
110
140
170
200
230
250
285
315
330
355
375
395
430
465
490
520
540
560
580
615
2,0
2,2
2,4
2,6
2,7
2,9
3,0
3,2
3,4
3,5
3,7
3,9
4,0
4,2
4,4
4,5
4,7
4,9
5,0
5,2
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use
(see page 19) and refer to the following table :
Ground
fitting
SOCKET
CLEVIS
EYE
EYE
EYE
CLEVIS
SOCKET
Y- CLEVIS
Y- CLEVIS
Line
fitting
BALL
TONGUE
EYE
BALL
TONGUE
BALL
EYE
TONGUE
EYE
Code
(2)
SB
CT
EE
EB
ET
CB
SE
YT
YE
Length
change (L)
0
-40
+55
+20
+5
-25
+30
+5
+50
isoelectric - Italy
24
04-2
Selection Guide
Catalogue
17
24
36
45
52
Code ()
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
n of
Sheds
A
n (1)
Length
L
10
mm
Leakage
distance
mm
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
395
435
475
515
555
595
635
675
715
755
795
835
875
915
955
995
1035
1075
1115
1155
255
370
485
600
715
830
945
1060
1175
1290
1405
1520
1635
1800
1915
2030
2150
2265
2380
2520
Dry arc
distance
Weight
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
95
135
175
215
255
295
335
375
415
455
495
535
575
615
655
695
735
775
815
855
65
75
85
100
110
120
135
150
160
175
190
215
230
250
260
280
290
300
315
330
55
60
70
85
100
110
120
130
140
155
165
180
200
220
230
250
260
270
280
300
100
130
160
180
200
220
240
260
280
305
325
340
370
410
450
480
500
520
540
570
110
140
170
200
230
250
285
315
330
355
375
395
430
465
490
520
540
560
580
615
2,0
2,2
2,4
2,6
2,7
2,9
3,0
3,2
3,4
3,5
3,7
3,9
4,0
4,2
4,4
4,5
4,7
4,9
5,0
5,2
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use
(see page 19) and refer to the following table :
Ground
fitting
SOCKET
CLEVIS
EYE
EYE
EYE
CLEVIS
SOCKET
Y- CLEVIS
Y- CLEVIS
Line
fitting
BALL
TONGUE
EYE
BALL
TONGUE
BALL
EYE
TONGUE
EYE
Code
(2)
SB
CT
EE
EB
ET
CB
SE
YT
YE
Length
change (L)
0
+35
+64
+29
+27
-8
-10
+15
+52
isoelectric - Italy
25
04-2
All our composite insulators are RIV and corona free through 170 kV, but corona shielding is necessary above 200 kV.
From 200 kV up to 300 kV is necessary to use one corona ring dia. 205 mm on the live end.
From 300 kV up to 400 kV is necessary to use two corona rings, dia. 385 mm on the live end & dia. 205 on the ground end.
From 300 kV up to 400 kV is necessary to use two corona rings, dia. 385 mm on the live end & dia. 205 on the ground end.
From 400 kV up to 500 kV is necessary to use two corona rings, dia. 385 mm on the live end & ground end.
When a corona ring is used the electrical characteristics can change.
These information are only for reference, it is necessary to verify the hardware condition to have final decision.
In this case, please, contact isoelectric.
Clamp-top Clamp
Our clamp-top clamp can be mounted on the Horizontal & Vertical line post insulators, that have the VC or the HC top end
fitting.
The clamp-top clamp is in aluminium and can be used with conductors from 10 mm up to 36 mm diameter size.
Please, don't hesitate to contact us directly for obtaining possible explanations or different solutions.
isoelectric - Italy
26
04-2
Selection Guide
(Line Voltage, kV)
72 123 145 170 250 400
Catalogue
Code ()
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
n of
Sheds
A
n (1)
Length
L
10
mm
Leakage
distance
mm
7
8
10
11
12
14
15
16
17
19
20
22
23
24
25
27
28
30
31
32
870
960
1140
1230
1320
1500
1590
1680
1770
1950
2040
2220
2310
2400
2490
2670
2760
2940
3030
3120
1360
1565
1975
2180
2385
2795
3000
3205
3410
3820
4025
4435
4640
4845
5050
5460
5665
6075
6280
6485
Dry arc
distance
Weight
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
620
710
890
980
1070
1250
1340
1430
1520
1700
1790
1970
2060
2150
2240
2420
2510
2690
2780
2870
240
270
340
370
405
450
480
510
540
615
625
675
710
760
810
840
855
890
905
915
210
240
265
290
325
370
400
425
450
515
525
575
605
640
675
690
710
740
750
760
400
460
560
610
650
720
760
810
880
1000
1040
1140
1210
1270
1330
1370
1415
1520
1585
1620
445
500
610
660
705
780
825
880
950
1080
1110
1230
1310
1370
1430
1470
1515
1640
1715
1750
3,7
5,2
5,7
6,2
6,7
7,2
7,7
8,2
8,7
9,2
9,7
10,2
10,7
11,2
11,7
12,2
12,7
13,2
13,7
14,2
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use
(see page 19) and refer to the following table :
Ground
fitting
SOCKET
SOCKET
EYE
EYE
EYE
CLEVIS
CLEVIS
Y- CLEVIS
Y- CLEVIS
Line
fitting
BALL
EYE
EYE
BALL
TONGUE
BALL
TONGUE
TONGUE
EYE
Code
(2)
SB
SE
EE
EB
ET
CB
CT
YT
YE
isoelectric - Italy
27
04-2
Selection Guide
(Line Voltage, kV)
72 123 145 170 250 400
Catalogue
Code ()
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
ISI-PAN-*
n of
Sheds
A
n (1)
Length
L
10
mm
Leakage
distance
mm
7
8
10
11
12
14
15
16
17
19
20
22
23
24
25
27
28
30
31
32
870
960
1140
1230
1320
1500
1590
1680
1770
1950
2040
2220
2310
2400
2490
2670
2760
2940
3030
3120
1360
1565
1975
2180
2385
2795
3000
3205
3410
3820
4025
4435
4640
4845
5050
5460
5665
6075
6280
6485
Dry arc
distance
Weight
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
620
710
890
980
1070
1250
1340
1430
1520
1700
1790
1970
2060
2150
2240
2420
2510
2690
2780
2870
240
270
340
370
405
450
480
510
540
615
625
675
710
760
810
840
855
890
905
915
210
240
265
290
325
370
400
425
450
515
525
575
605
640
675
690
710
740
750
760
400
460
560
610
650
720
760
810
880
1000
1040
1140
1210
1270
1330
1370
1415
1520
1585
1620
445
500
610
660
705
780
825
880
950
1080
1110
1230
1310
1370
1430
1470
1515
1640
1715
1750
3,7
5,2
5,7
6,2
6,7
7,2
7,7
8,2
8,7
9,2
9,7
10,2
10,7
11,2
11,7
12,2
12,7
13,2
13,7
14,2
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use
(see page 19) and refer to the following table :
Ground
fitting
SOCKET
SOCKET
EYE
EYE
EYE
CLEVIS
CLEVIS
Y- CLEVIS
Y- CLEVIS
Line
fitting
BALL
EYE
EYE
BALL
TONGUE
BALL
TONGUE
TONGUE
EYE
Code
(2)
SB
SE
EE
EB
ET
CB
CT
YT
YE
isoelectric - Italy
28
04-2
S solution
R solution
Selection Guide
(Line Voltage, kV)
72 123 145 170 250 400
Catalogue
Code ()
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
n of
Sheds
A
n (1)
Length
L
10
mm
Leakage
distance
mm
15
18
21
24
27
30
33
36
39
42
45
48
51
54
57
60
63
66
69
72
825
945
1065
1185
1305
1425
1545
1665
1785
1905
2025
2145
2265
2385
2505
2625
2745
2865
2985
3105
1800
2150
2520
2870
3240
3605
3950
4320
4690
5050
5410
5790
6140
6500
6860
7220
7570
7930
8290
8650
Dry arc
distance
Weight
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
615
735
855
975
1095
1215
1335
1455
1575
1695
1815
1935
2055
2175
2295
2415
2535
2655
2775
2895
250
290
340
380
415
450
485
520
565
615
645
675
710
760
810
860
875
890
905
920
220
260
265
300
335
370
405
435
475
515
545
575
605
640
675
710
720
740
750
760
410
500
570
620
670
720
770
830
915
1000
1070
1140
1210
1270
1330
1390
1455
1520
1585
1650
465
540
615
670
725
780
835
900
990
1080
1155
1230
1310
1370
1430
1490
1565
1640
1715
1800
4,2
4,7
5,2
5,7
6,2
6,7
7,2
7,7
8,2
8,7
9,2
9,7
10,2
10,7
11,2
11,7
12,2
12,7
13,2
13,7
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use
(see page 19) and refer to the following table :
Ground
fitting
SOCKET
CLEVIS
EYE
EYE
EYE
CLEVIS
SOCKET
Y- CLEVIS
Y- CLEVIS
Line
fitting
BALL
TONGUE
EYE
BALL
TONGUE
BALL
EYE
TONGUE
EYE
Code
(2)
SB
CT
EE
EB
ET
CB
SE
YT
YE
Length
change (L)
0
-40
+55
+20
+5
-25
+30
+5
+50
isoelectric - Italy
29
04-2
S solution
R solution
Selection Guide
(Line Voltage, kV)
72 123 145 170 250 400
Catalogue
Code ()
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
n of
Sheds
A
n (1)
Length
L
10
mm
Leakage
distance
mm
15
18
21
24
27
30
33
36
39
42
45
48
51
54
57
60
63
66
69
72
915
1035
1155
1275
1395
1515
1635
1755
1875
1995
2115
2235
2355
2475
2595
2715
2835
2955
3075
3195
1800
2150
2520
2870
3240
3605
3950
4320
4690
5050
5410
5790
6140
6500
6860
7220
7570
7930
8290
8650
Dry arc
distance
Weight
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
615
735
855
975
1095
1215
1335
1455
1575
1695
1815
1935
2055
2175
2295
2415
2535
2655
2775
2895
250
290
340
380
415
450
485
520
565
615
645
675
710
760
810
860
875
890
905
920
220
260
265
300
335
370
405
435
475
515
545
575
605
640
675
710
720
740
750
760
410
500
570
620
670
720
770
830
915
1000
1070
1140
1210
1270
1330
1390
1455
1520
1585
1650
465
540
615
670
725
780
835
900
990
1080
1155
1230
1310
1370
1430
1490
1565
1640
1715
1800
4,2
4,7
5,2
5,7
6,2
6,7
7,2
7,7
8,2
8,7
9,2
9,7
10,2
10,7
11,2
11,7
12,2
12,7
13,2
13,7
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use
(see page 19) and refer to the following table :
Ground
fitting
SOCKET
CLEVIS
EYE
EYE
EYE
CLEVIS
SOCKET
Y- CLEVIS
Y- CLEVIS
Line
fitting
BALL
TONGUE
EYE
BALL
TONGUE
BALL
EYE
TONGUE
EYE
Code
(2)
SB
CT
EE
EB
ET
CB
SE
YT
YE
Length
change (L)
0
-10
+64
+29
+27
-8
-10
+15
+52
isoelectric - Italy
30
04-2
S solution
R solution
Selection Guide
(Line Voltage, kV)
72 123 145 170 250 400
Catalogue
Code ()
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
ISI-CAN-*
n of
Sheds
A
n (1)
Length
L
10
mm
Leakage
distance
mm
15
18
21
24
27
30
33
36
39
42
45
48
51
54
57
60
63
66
69
72
925
1045
1165
1285
1405
1525
1645
1765
1885
2005
2125
2245
2365
2485
2605
2725
2845
2965
3085
3205
1800
2150
2520
2870
3240
3605
3950
4320
4690
5050
5410
5790
6140
6500
6860
7220
7570
7930
8290
8650
Dry arc
distance
Weight
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
615
735
855
975
1095
1215
1335
1455
1575
1695
1815
1935
2055
2175
2295
2415
2535
2655
2775
2895
250
290
340
380
415
450
485
520
565
615
645
675
710
760
810
860
875
890
905
920
220
260
265
300
335
370
405
435
475
515
545
575
605
640
675
710
720
740
750
760
410
500
570
620
670
720
770
830
915
1000
1070
1140
1210
1270
1330
1390
1455
1520
1585
1650
465
540
615
670
725
780
835
900
990
1080
1155
1230
1310
1370
1430
1490
1565
1640
1715
1800
4,2
4,7
5,2
5,7
6,2
6,7
7,2
7,7
8,2
8,7
9,2
9,7
10,2
10,7
11,2
11,7
12,2
12,7
13,2
13,7
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use
(see page 19) and refer to the following table :
Ground
fitting
SOCKET
SOCKET
EYE
EYE
EYE
CLEVIS
CLEVIS
Y- CLEVIS
Y- CLEVIS
Line
fitting
BALL
EYE
EYE
BALL
TONGUE
BALL
TONGUE
TONGUE
EYE
Code
(2)
SB
SE
EE
EB
ET
CB
CT
YT
YE
Length
change (L)
0
+25
+54
+19
+17
+2
0
+5
+42
isoelectric - Italy
31
04-2
S solution
R solution
Selection Guide
(Line Voltage, kV)
72 123 145 170 250 400
n of
Sheds
A
n (1)
Catalogue
Code ()
Length
L
10
mm
Leakage
distance
mm
Dry arc
distance
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
Weight
kg
ISI-ROK-*
9+8
850
2270
640
275
195
460
495
4,4
ISI-ROK-*
10+9
920
2530
710
310
230
515
550
4,9
ISI-ROK-*
12+11 1060
3050
850
340
265
570
615
5,4
ISI-ROK-*
14+13 1200
3570
990
380
300
620
670
5,9
ISI-ROK-*
15+14 1270
3830
1060
415
335
670
725
6,4
ISI-ROK-*
17+16 1410
4350
1200
450
370
720
780
6,9
ISI-ROK-*
19+18 1550
4870
1340
485
405
770
835
7,4
ISI-ROK-*
21+20 1690
5390
1480
520
435
830
900
7,9
ISI-ROK-*
22+21 1760
5650
1550
565
475
915
990
8,4
ISI-ROK-*
24+23 1900
6170
1690
615
515
1000
1080
8,9
ISI-ROK-*
26+25 2040
6690
1830
645
545
1070
1155
9,4
ISI-ROK-*
27+26 2110
6950
1900
675
575
1140
1230
9,7
ISI-ROK-*
29+28 2250
7470
2040
710
605
1210
1310
10,4
ISI-ROK-*
31+30 2390
8100
2180
760
640
1270
1370
10,9
ISI-ROK-*
33+32 2530
8620
2320
810
675
1330
1430
11,4
ISI-ROK-*
35+34 2670
9180
2460
860
710
1390
1490
11,9
ISI-ROK-*
36+35 2740
9440
2530
875
720
1455
1565
12,4
ISI-ROK-*
38+37 2880
9990
2670
890
740
1520
1640
12,9
ISI-ROK-*
42+41 3160
11000
2950
920
760
1650
1800
13,9
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use
(see page 19) and refer to the following table:
Ground
fitting
SOCKET
CLEVIS
EYE
EYE
EYE
CLEVIS
SOCKET
Y- CLEVIS
Y- CLEVIS
Line
fitting
BALL
TONGUE
EYE
BALL
TONGUE
BALL
EYE
TONGUE
EYE
Code
(2)
SB
CT
EE
EB
ET
CB
SE
YT
YE
Length
change (L)
0
-40
+55
+20
+5
-25
+30
+5
+50
isoelectric - Italy
32
04-2
S solution
R solution
Selection Guide
(Line Voltage, kV)
72 123 145 170 250 400
n of
Sheds
A
n (1)
Catalogue
Code ()
Length
L
10
mm
Leakage
distance
mm
Dry arc
distance
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
Weight
kg
ISI-ROK-*
9+8
940
2270
640
275
195
460
495
4,4
ISI-ROK-*
10+9
1010
2530
710
310
230
515
550
4,9
ISI-ROK-*
12+11 1150
3050
850
340
265
570
615
5,4
ISI-ROK-*
14+13 1290
3570
990
380
300
620
670
5,9
ISI-ROK-*
15+14 1360
3830
1060
415
335
670
725
6,4
ISI-ROK-*
17+16 1500
4350
1200
450
370
720
780
6,9
ISI-ROK-*
19+18 1640
4870
1340
485
405
770
835
7,4
ISI-ROK-*
21+20 1780
5390
1480
520
435
830
900
7,9
ISI-ROK-*
22+21 1850
5650
1550
565
475
915
990
8,4
ISI-ROK-*
24+23 1990
6170
1690
615
515
1000
1080
8,9
ISI-ROK-*
26+25 2130
6690
1830
645
545
1070
1155
9,4
ISI-ROK-*
27+26 2200
6950
1900
675
575
1140
1230
9,7
ISI-ROK-*
29+28 2340
7470
2040
710
605
1210
1310
10,4
ISI-ROK-*
31+30 2480
8100
2180
760
640
1270
1370
10,9
ISI-ROK-*
33+32 2620
8620
2320
810
675
1330
1430
11,4
ISI-ROK-*
35+34 2760
9180
2460
860
710
1390
1490
11,9
ISI-ROK-*
36+35 2830
9440
2530
875
720
1455
1565
12,4
ISI-ROK-*
38+37 2970
9990
2670
890
740
1520
1640
12,9
ISI-ROK-*
42+41 3250
11000
2950
920
760
1650
1800
13,9
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use
(see page 19) and refer to the following table :
Ground
fitting
SOCKET
CLEVIS
EYE
EYE
EYE
CLEVIS
SOCKET
Y- CLEVIS
Y- CLEVIS
Line
fitting
BALL
TONGUE
EYE
BALL
TONGUE
BALL
EYE
TONGUE
EYE
Code
(2)
SB
CT
EE
EB
ET
CB
SE
YT
YE
Length
change (L)
0
-10
+64
+29
+27
-8
-10
+15
+52
isoelectric - Italy
33
06-10
S solution
R solution
Selection Guide
(Line Voltage, kV)
72 123 145 170 250 400
n of
Sheds
A
n (1)
Catalogue
Code ()
Length
L
10
mm
Leakage
distance
mm
Dry arc
distance
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
Weight
kg
ISI-ROK-*
9+8
950
2270
640
275
195
460
495
4,4
ISI-ROK-*
10+9
1020
2530
710
310
230
515
550
4,9
ISI-ROK-*
12+11 1160
3050
850
340
265
570
615
5,4
ISI-ROK-*
14+13 1300
3570
990
380
300
620
670
5,9
ISI-ROK-*
15+14 1370
3830
1060
415
335
670
725
6,4
ISI-ROK-*
17+16 1510
4350
1200
450
370
720
780
6,9
ISI-ROK-*
19+18 1650
4870
1340
485
405
770
835
7,4
ISI-ROK-*
21+20 1790
5390
1480
520
435
830
900
7,9
ISI-ROK-*
22+21 1860
5650
1550
565
475
915
990
8,4
ISI-ROK-*
24+23 2000
6170
1690
615
515
1000
1080
8,9
ISI-ROK-*
26+25 2140
6690
1830
645
545
1070
1155
9,4
ISI-ROK-*
27+26 2210
6950
1900
675
575
1140
1230
9,7
ISI-ROK-*
29+28 2350
7470
2040
710
605
1210
1310
10,4
ISI-ROK-*
31+30 2490
8100
2180
760
640
1270
1370
10,9
ISI-ROK-*
33+32 2630
8620
2320
810
675
1330
1430
11,4
ISI-ROK-*
35+34 2770
9180
2460
860
710
1390
1490
11,9
ISI-ROK-*
36+35 2840
9440
2530
875
720
1455
1565
12,4
ISI-ROK-*
38+37 2980
9990
2670
890
740
1520
1640
12,9
ISI-ROK-*
42+41 3260
11000
2950
920
760
1650
1800
13,9
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use
(see page 19) and refer to the following table :
Ground
fitting
SOCKET
SOCKET
EYE
EYE
EYE
CLEVIS
CLEVIS
Y- CLEVIS
Y- CLEVIS
Line
fitting
BALL
EYE
EYE
BALL
TONGUE
BALL
TONGUE
TONGUE
EYE
Code
(2)
SB
SE
EE
EB
ET
CB
CT
YT
YE
Length
change (L)
0
+25
+54
+19
+17
+2
0
+5
+42
isoelectric - Italy
34
04-2
S solution
R solution
Selection Guide
(Line Voltage, kV)
72 123 145 170 250 400
n of
Sheds
A
n (1)
Catalogue
Code ()
Lightning impul.
withstand 1,2/50
posit.
kV
negat.
kV
Weight
kg
ISI-TWA-*
8+7
890
2600
590
260
180
435
470
5,2
ISI-TWA-*
9+8
965
2950
665
285
200
475
510
5,7
ISI-TWA-*
12+11 1190
4000
890
355
280
585
630
6,2
ISI-TWA-*
13+12 1265
4300
965
380
300
620
670
6,7
ISI-TWA-*
16+15 1490
5330
1190
435
355
720
760
7,2
ISI-TWA-*
17+16 1565
5680
1265
460
380
740
795
7,7
ISI-TWA-*
18+17 1640
6000
1340
485
405
770
835
8,2
ISI-TWA-*
20+19 1790
6700
1490
525
440
840
910
8,7
ISI-TWA-*
21+20 1865
7010
1565
565
475
915
990
9,2
ISI-TWA-*
23+22 2015
7720
1715
620
520
1010
1100
9,7
ISI-TWA-*
25+24 2165
8400
1865
645
545
1050
1155
10,2
ISI-TWA-*
26+25 2240
8750
1940
675
575
1140
1230
10,7
ISI-TWA-*
27+26 2315
9100
2015
715
615
1215
1310
11,2
ISI-TWA-*
29+28 2465
9780
2165
760
640
1270
1370
11,7
ISI-TWA-*
31+30 2615 10500
2315
815
680
1340
1440
12,2
ISI-TWA-*
32+31 2690 10800
2390
850
700
1370
1470
12,7
ISI-TWA-*
34+33 2840 11480
2540
875
720
1455
1565
13,2
ISI-TWA-*
36+35 2990 12200
2690
895
745
1530
1650
13,7
ISI-TWA-*
37+36 3065 12510
2765
900
745
1580
1710
14,2
ISI-TWA-*
40+39 3290 13600
2990
950
790
1700
1840
14,7
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use
(see page 19) and refer to the following table :
Ground
fitting
SOCKET
SOCKET
EYE
EYE
EYE
CLEVIS
CLEVIS
Y- CLEVIS
Y- CLEVIS
Line
fitting
BALL
EYE
EYE
BALL
TONGUE
BALL
TONGUE
TONGUE
EYE
Code
(2)
SB
SE
EE
EB
ET
CB
CT
YT
YE
Length
change (L)
0
-10
+64
+29
+27
-8
-10
+15
+52
isoelectric - Italy
35
06-10
S solution
R solution
Selection Guide
(Line Voltage, kV)
72 123 145 170 250 400
n of
Sheds
A
n (1)
Catalogue
Code ()
Lightning impul.
withstand 1,2/50
posit.
kV
negat.
kV
Weight
kg
ISI-TWA-*
8+7
900
2600
590
260
180
435
470
5,2
ISI-TWA-*
9+8
975
2950
665
285
200
475
510
5,7
ISI-TWA-*
12+11 1200
4000
890
355
280
585
630
6,2
ISI-TWA-*
13+12 1275
4300
965
380
300
620
670
6,7
ISI-TWA-*
16+15 1500
5330
1190
435
355
720
760
7,2
ISI-TWA-*
17+16 1575
5680
1265
460
380
740
795
7,7
ISI-TWA-*
18+17 1650
6000
1340
485
405
770
835
8,2
ISI-TWA-*
20+19 1800
6700
1490
525
440
840
910
8,7
ISI-TWA-*
21+20 1875
7010
1565
565
475
915
990
9,2
ISI-TWA-*
23+22 2025
7720
1715
620
520
1010
1100
9,7
ISI-TWA-*
25+24 2175
8400
1865
645
545
1050
1155
10,2
ISI-TWA-*
26+25 2250
8750
1940
675
575
1140
1230
10,7
ISI-TWA-*
27+26 2325
9100
2015
715
615
1215
1310
11,2
ISI-TWA-*
29+28 2475
9780
2165
760
640
1270
1370
11,7
ISI-TWA-*
31+30 2625 10500
2315
815
680
1340
1440
12,2
ISI-TWA-*
32+31 2700 10800
2390
850
700
1370
1470
12,7
ISI-TWA-*
34+33 2850 11480
2540
875
720
1455
1565
13,2
ISI-TWA-*
36+35 3000 12200
2690
895
745
1530
1650
13,7
ISI-TWA-*
37+36 3075 12510
2765
900
745
1580
1710
14,2
ISI-TWA-*
40+39 3300 13600
2990
950
790
1700
1840
14,7
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use
(see page 19) and refer to the following table :
Ground
fitting
SOCKET
SOCKET
EYE
EYE
EYE
CLEVIS
CLEVIS
Y- CLEVIS
Y- CLEVIS
Line
fitting
BALL
EYE
EYE
BALL
TONGUE
BALL
TONGUE
TONGUE
EYE
Code
(2)
SB
SE
EE
EB
ET
CB
CT
YT
YE
Length
change (L)
0
+25
+54
+19
+17
+2
0
+5
+42
isoelectric - Italy
36
04-2
Selection Guide
Catalogue
Code ()
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
n of
Sheds
A
n (1)
Length
L
10
mm
Leakage
distance
mm
30+29
33+32
36+35
40+39
42+41
46+45
50+49
52+51
55+54
58+57
61+60
64+63
67+66
70+69
73+72
76+75
79+78
82+81
85+84
93+92
1965
2125
2290
2505
2610
2825
3040
3150
3310
3475
3635
3800
3960
4125
4285
4450
4610
4770
4935
5365
7300
8040
8780
9760
10250
11200
12210
12700
13400
14150
14900
15640
16370
17100
17800
18580
19300
20050
20785
22500
Dry arc
distance
Weight
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
1705
1865
2030
2245
2350
2565
2780
2890
3050
3215
3375
3540
3700
3865
4025
4190
4350
4510
4675
5105
610
645
700
740
815
865
900
950
1000
1040
1090
1110
1140
1170
1200
1220
1250
1280
1310
1460
510
545
595
620
660
710
750
830
900
950
1000
1030
1050
1075
1100
1130
1150
1175
1200
1310
990
1050
1200
1250
1340
1475
1570
1610
1700
1780
1860
1980
2030
2110
2220
2260
2400
2500
2590
2890
1070
1155
1300
1350
1440
1585
1720
1790
1850
1900
1950
2090
2110
2205
2300
2350
2520
2610
2720
3040
9.5
10.3
11.3
12.3
13.3
14.3
15.3
16.3
17.3
18.3
19.3
20.3
21.3
22.3
23.3
24.3
25.3
26.3
27.3
29.5
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), select the kind of fitting end you have to use (see page 19)
and refer to the following table :
Ground
fitting
SOCKET
CLEVIS
EYE
Y- CLEVIS
EYE
CLEVIS
Line
fitting
BALL
TONGUE
EYE
TONGUE
BALL
BALL
Code
(2)
SB
CT
EE
YT
EB
CB
Length
change (L)
0
-10
+70
+15
+29
-8
isoelectric - Italy
37
09-1
Selection Guide
Catalogue
Code ()
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
ISI-TWX-*
n of
Sheds
A
n (1)
Length
L
10
mm
Leakage
distance
mm
30+29
33+32
36+35
40+39
42+41
46+45
50+49
52+51
55+54
58+57
61+60
64+63
67+66
70+69
73+72
76+75
79+78
82+81
85+84
93+92
1980
2140
2305
2520
2625
2840
3055
3165
3325
3490
3650
3815
3975
4140
4300
4465
4625
4785
4950
5380
7300
8040
8780
9760
10250
11200
12210
12700
13400
14150
14900
15640
16370
17100
17800
18580
19300
20050
20785
22500
Dry arc
distance
Weight
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
1705
1865
2030
2245
2350
2565
2780
2890
3050
3215
3375
3540
3700
3865
4025
4190
4350
4510
4675
5105
610
645
700
740
815
865
900
950
1000
1040
1090
1110
1140
1170
1200
1220
1250
1280
1310
1460
510
545
595
620
660
710
750
830
900
950
1000
1030
1050
1075
1100
1130
1150
1175
1200
1310
990
1050
1200
1250
1340
1475
1570
1610
1700
1780
1860
1980
2030
2110
2220
2260
2400
2500
2590
2890
1070
1155
1300
1350
1440
1585
1720
1790
1850
1900
1950
2090
2110
2205
2300
2350
2520
2610
2720
3040
9.5
10.3
11.3
12.3
13.3
14.3
15.3
16.3
17.3
18.3
19.3
20.3
21.3
22.3
23.3
24.3
25.3
26.3
27.3
29.5
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), select the kind of fitting end you have to use (see page 19)
and refer to the following table :
Ground
fitting
SOCKET- 20
CLEVIS
EYE 25
EYE 25
CLEVIS
Line
fitting
BALL - 20
TONGUE
EYE 25
BALL 20
BALL - 20
Code
(2)
SB
CT
EE
EB
CB
Length
change (L)
0
+10
+100
+45
-8
isoelectric - Italy
38
09-1
Selection Guide
Catalogue
Code ()
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
n of
Sheds
A
n (1)
Length
L
10
mm
Leakage
distance
mm
10+9
11+10
13+12
14+13
15+14
17+16
18+17
19+18
21+20
22+21
23+22
24+23
26+25
27+26
29+28
33+32
35+34
38+37
42+41
48+47
1225
1315
1495
1585
1675
1855
1945
2035
2215
2305
2395
2485
2665
2755
2935
3295
3475
3745
4110
4645
2910
3210
3805
4100
4400
5000
5295
5590
6190
6490
6785
7080
7680
7975
8570
9760
10360
11150
12400
14200
Dry arc
distance
Weight
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
915
1005
1185
1275
1365
1545
1635
1725
1905
1995
2085
2175
2355
2445
2625
2985
3165
3435
3800
4335
350
380
415
455
480
525
570
610
645
685
700
740
815
845
865
900
930
960
1140
1280
275
300
335
375
400
440
480
510
545
585
595
620
660
685
710
750
780
820
1020
1100
580
620
670
725
765
840
920
990
1050
1150
1200
1250
1340
1380
1475
1670
1730
1780
2030
2400
625
670
725
785
830
910
995
1070
1155
1240
1300
1350
1440
1480
1585
1820
1860
1930
2110
2510
7,2
7,7
8,2
8,7
9,2
9,7
10,2
10,7
11,2
11,7
12,2
12,7
13,2
13,7
14,2
15,7
18.2
20.7
22.8
23.6
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use
(see page 19) and refer to the following table :
Ground
fitting
SOCKET
SOCKET
EYE
EYE
EYE
CLEVIS
CLEVIS
Y- CLEVIS
Y- CLEVIS
Line
fitting
BALL
EYE
EYE
BALL
TONGUE
BALL
TONGUE
TONGUE
EYE
Code
(2)
SB
SE
EE
EB
ET
CB
CT
YT
YE
Length
change (L)
0
+40
+70
+30
+40
0
+10
+20
+50
isoelectric - Italy
39
04-2
Selection Guide
Catalogue
Code ()
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
ISI-SOR-*
n of
Sheds
A
n (1)
Length
L
10
mm
Leakage
distance
mm
10+9
11+10
13+12
14+13
15+14
17+16
18+17
19+18
21+20
22+21
23+22
24+23
26+25
27+26
29+28
33+32
35+34
38+37
42+41
48+47
1325
1415
1595
1685
1775
1955
2045
2135
2315
2405
2495
2585
2765
2855
3035
3395
3575
3845
4210
4745
2910
3210
3805
4100
4400
5000
5295
5590
6190
6490
6785
7080
7680
7975
8570
9760
10360
11150
12400
14200
Dry arc
distance
Weight
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
915
1005
1185
1275
1365
1545
1635
1725
1905
1995
2085
2175
2355
2445
2625
2985
3165
3435
3800
4335
350
380
415
455
480
525
570
610
645
685
700
740
815
845
865
900
930
960
1140
1280
275
300
335
375
400
440
480
510
545
585
595
620
660
685
710
750
780
820
1020
1100
580
620
670
725
765
840
920
990
1050
1150
1200
1250
1340
1380
1475
1670
1730
1780
2030
2400
625
670
725
785
830
910
995
1070
1155
1240
1300
1350
1440
1480
1585
1820
1860
1930
2110
2510
7,2
7,7
8,2
8,7
9,2
9,7
10,2
10,7
11,2
11,7
12,2
12,7
13,2
13,7
14,2
15,7
18.2
20.7
22.8
23.6
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use
(see page 19) and refer to the following table :
Ground
fitting
SOCKET
CLEVIS
SOCKET
CLEVIS
Line
fitting
BALL
BALL
TONGUE
TONGUE
Code
(2)
SB
CB
ST
CT
Length
change (L)
0
0
0
0
isoelectric - Italy
40
04-2
Selection Guide
Catalogue
Code ()
ISI-TEN-*
ISI-TEN-*
ISI-TEN-*
ISI-TEN-*
ISI-TEN-*
ISI-TEN-*
ISI-TEN-*
ISI-TEN-*
ISI-TEN-*
ISI-TEN-*
ISI-TEN-*
ISI-TEN-*
ISI-TEN-*
ISI-TEN-*
ISI-TEN-*
ISI-TEN-*
ISI-TEN-*
ISI-TEN-*
ISI-TEN-*
ISI-TEN-*
n of
Sheds
A
n (1)
Length
L
10
mm
Leakage
distance
mm
38
42
46
50
54
58
62
66
70
74
78
82
86
90
94
98
102
106
110
120
2125
2285
2450
2615
2780
2945
3105
3270
3435
3600
3765
3925
4090
4255
4420
4580
4745
4910
5075
5485
5370
5910
6450
7000
7530
8070
8610
9150
9690
10230
10770
11310
11850
12390
12930
13470
14010
14550
15090
16440
Dry arc
distance
Weight
mm
Dry
kV
Wet
kV
posit.
kV
negat.
kV
kg
1720
1880
2045
2210
2375
2540
2700
2865
3030
3195
3360
3520
3685
3850
4015
4175
4340
4505
4670
5080
610
645
700
740
815
865
900
950
1000
1040
1090
1110
1140
1170
1200
1220
1250
1280
1310
1460
510
545
595
620
660
710
750
830
900
950
1000
1030
1050
1075
1100
1130
1150
1175
1200
1310
990
1050
1200
1250
1340
1475
1570
1610
1700
1780
1860
1980
2030
2110
2220
2260
2400
2500
2590
2890
1070
1155
1300
1350
1440
1585
1720
1790
1850
1900
1950
2090
2110
2205
2300
2350
2520
2610
2720
3040
9.5
10.3
11.3
12.3
13.3
14.3
15.3
16.3
17.3
18.3
19.3
20.3
21.3
22.3
23.3
24.3
25.3
26.3
27.3
29.5
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use
(see page 19) and refer to the following table :
Ground
fitting
CLEVIS
CLEVIS
TONGUE
SOCKET
Line
fitting
TONGUE
CLEVIS
TONGUE
BALL
Code
(2)
CT
CC
TT
SB
Length
change (L)
0
- 60
+65
0
isoelectric - Italy
41
09-1
isoelectric - Italy
42
04-2
Selection Guide
Catalogue
17
24
36
45
52
Code ()
ISI-SAS-*
ISI-SAS-*
ISI-SAS-*
ISI-SAS-*
ISI-SAS-*
ISI-SAS-*
ISI-SAS-*
ISI-SAS-*
2
3
4
5
6
7
8
9
200
240
280
320
360
400
440
480
310
445
580
715
850
985
1120
1255
135
175
215
255
295
335
375
415
60
70
80
90
110
120
135
150
50
60
70
80
100
110
120
130
90
120
145
160
165
180
200
220
160
200
240
270
280
310
340
370
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total height of the insulator (H), please, select the kind of fitting end you have to use and
make the opportune correction with reference to the following table:
Line
fitting
Fitting P1
Fitting P1
Fitting M2
Fitting P1
Fitting M1
Fitting P2
Fitting P2
Fitting P2
Fitting R
Ground
fitting
Fitting D
Fitting R
Fitting M1
Fitting M1
Fitting R
Fitting D
Fitting R
Fitting M1
Fitting R
Code
(2)
P1D
P1R
M2M1
P1M1
M1R
P2D
P2R
P2M1
RR
Height
change (H)
0
-10
-15
-5
-5
+10
0
+5
-10
isoelectric - Italy
43
05-1
Selection Guide
(Line Voltage, kV)
12
24
36
45
Catalogue
Code ()
ISI-RG-*
ISI-RG-*
ISI-RG-*
ISI-RG-*
ISI-RG-*
ISI-RG-*
ISI-RG-*
2+1
3+2
4+3
5+4
6+5
7+6
8+7
185
245
305
365
425
485
545
335
540
750
960
1170
1380
1590
110
170
230
290
330
390
450
70
110
120
150
160
180
200
65
100
110
140
150
165
185
115
150
180
235
260
285
305
160
190
215
270
300
325
355
2,0
2,5
3,0
3,5
3,9
4,4
5,0
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total height of the insulator (H), please, select the kind of fitting end you have to use and
make the opportune correction with reference to the following table :
Line
fitting
Fitting P1
Fitting P2
Fitting P1
Fitting P2
Fitting F-neck
Fitting F-neck
Fitting C
Fitting C
Ground
fitting
Fitting D
Fitting D
Fitting R
Fitting R
Fitting D
Fitting R
Fitting D
Fitting R
Code
(2)
P1D
P2D
P1R
P2R
F-neckD
F-neckR
CD
CR
Height
change (H)
0
+5
0
+20
+25
+45
+45
+100
isoelectric - Italy
44
06-10
Selection Guide
Catalogue
17
24
36
45
52
Code ()
ISI-Fn-*
ISI-Fn-*
ISI-Fn-*
ISI-Fn-*
ISI-Fn-*
ISI-Fn-*
ISI-Fn-*
ISI-Fn-*
2
3
4
5
6
7
8
9
170
215
260
305
350
395
440
485
265
370
475
580
685
790
895
1000
150
195
240
295
330
375
420
465
65
75
85
110
120
135
150
160
60
65
75
100
110
120
130
140
100
130
150
165
180
200
220
245
180
220
250
280
310
340
370
395
2,0
2,5
3,0
3,5
4,0
4,5
5,0
5,5
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total height of the insulator (H), please, select the kind of fitting end you have to use and
make the opportune correction with reference to the following table :
Line
fitting
Fitting R
Fitting F
Fitting G
Fitting M
Fitting M
Fitting M
Fitting VC
Fitting VC
Fitting VC
Ground
fitting
Fitting R
Fitting R
Fitting G
Fitting R
Fitting G
Fitting M
Fitting R
Fitting G
Fitting M
Code
(2)
RR
FR
GG
MR
MG
MM
VCR
VCG
VCM
Height
change (H)
0
0
+160
0
+80
0
+95
+175
+95
isoelectric - Italy
45
06-10
Selection Guide
Catalogue
17
24
36
45
52
Code ()
ISI-SCA-*
ISI-SCA-*
ISI-SCA-*
ISI-SCA-*
ISI-SCA-*
ISI-SCA-*
ISI-SCA-*
ISI-SCA-*
2+1
3+2
4+3
5+4
6+5
7+6
8+7
9+8
190
240
285
335
385
430
480
525
315
465
610
760
910
1055
1205
1350
160
210
255
305
355
400
450
495
65
95
110
120
150
170
180
190
60
85
95
110
140
155
165
175
100
130
155
180
235
270
285
300
150
170
190
215
270
300
325
345
2,0
2,5
3,0
3,5
4,0
4,5
5,0
5,5
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total height of the insulator (H), please, select the kind of fitting end you have to use and
make the opportune correction with reference to the following table :
Line
fitting
Fitting M2
Fitting F
Fitting R
Fitting M2
Fitting M2
Ground
fitting
Fitting M1
Fitting R
Fitting R
Fitting R
Fitting F
Code
(2)
M2M1
FR
RR
M2R
M2F
Height
change (H)
0
+15
+15
+8
+8
isoelectric - Italy
46
11-1
Selection Guide
Catalogue
17
24
36
45
52
Code ()
ISI-FC-*
ISI-FC-*
ISI-FC-*
ISI-FC-*
ISI-FC-*
ISI-FC-*
ISI-FC-*
ISI-FC-*
2+1
3+2
4+3
5+4
6+5
7+6
8+7
9+8
185
245
305
365
425
485
545
605
390
585
780
975
1170
1365
1560
1755
165
225
285
345
405
465
525
585
70
110
120
150
170
180
200
225
65
100
110
140
155
165
185
210
115
150
180
235
270
285
305
345
160
190
215
270
300
325
355
405
2,0
2,5
3,0
3,5
4,0
4,5
5,0
5,5
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total height of the insulator (H), please, select the kind of fitting end you have to use and
make the opportune correction with reference to the following table :
Line
fitting
Fitting R
Fitting F
Fitting G
Fitting M
Fitting M
Fitting M
Fitting VC
Fitting VC
Fitting VC
Ground
fitting
Fitting R
Fitting R
Fitting G
Fitting R
Fitting G
Fitting M
Fitting R
Fitting G
Fitting M
Code
(2)
RR
FR
GG
MR
MG
MM
VCR
VCG
VCM
Height
change (H)
0
0
+160
0
+80
0
+95
+175
+95
isoelectric - Italy
47
06-10
Selection Guide
(Line Voltage, kV)
72
115
150
Catalogue
Code ()
ISI-FC-*
ISI-FC-*
ISI-FC-*
ISI-FC-*
ISI-FC-*
ISI-FC-*
ISI-FC-*
ISI-FC-*
10+9
12+11
14+13
16+15
18+17
20+19
22+21
24+23
665
785
905
1025
1145
1265
1385
1505
1950
2340
2730
3120
3510
3900
4290
4680
645
765
885
1005
1125
1245
1365
1485
270
310
355
400
435
475
520
560
225
245
285
320
355
390
430
475
450
515
570
625
680
750
820
870
490
550
615
670
735
805
890
940
6,0
7,0
8,0
9,0
10,0
11,0
12,0
13,0
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total height of the insulator (H), please, select the kind of fitting end you have to use and
make the opportune correction with reference to the following table :
Line
fitting
Fitting R
Fitting F
Fitting G
Fitting M
Fitting M
Fitting M
Fitting VC
Fitting VC
Fitting VC
Ground
fitting
Fitting R
Fitting R
Fitting G
Fitting R
Fitting G
Fitting M
Fitting R
Fitting G
Fitting M
Code
(2)
RR
FR
GG
MR
MG
MM
VCR
VCG
VCM
Height
change (H)
0
0
+160
0
+80
0
+95
+175
+95
isoelectric - Italy
48
06-10
Selection Guide
Catalogue
17
24
36
45
52
Code ()
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
2+1
3+2
4+3
5+4
6+5
7+6
8+7
9+8
315
375
435
495
555
615
675
735
340
530
710
900
1100
1280
1470
1660
135
195
255
315
375
435
495
555
65
80
100
125
145
170
190
215
60
75
90
110
130
155
175
200
100
135
160
190
220
255
290
320
145
180
210
240
275
310
340
380
6,5
7,0
7,5
8,0
8,5
9,0
9,5
10,0
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total height of the insulator (H), please, select the kind of fitting end you have to use and
make the opportune correction with reference to the following table :
Line
fitting
Fitting G
Fitting MG
Fitting VC
Fitting G
Fitting VC
Ground
fitting
Fitting G
Fitting G
Fitting G
Fitting MG
Fitting MG
Code
(2)
GG
MGG
VCG
GMG
VCMG
Height
change (H)
0
+20
+10
+20
+75
isoelectric - Italy
49
06-10
Selection Guide
(Line Voltage, kV)
72
115
150 230
Catalogue
Code ()
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
10+9
12+11
14+13
16+15
18+17
20+19
22+21
24+23
28+27
32+31
36+35
795
915
1035
1155
1275
1395
1515
1635
1875
2115
2360
1800
2200
2600
2900
3300
3700
4100
4450
5200
5950
6700
615
735
855
975
1095
1215
1335
1455
1695
1935
2175
275
310
340
380
415
450
485
520
615
675
760
195
230
265
300
335
370
405
435
515
575
640
420
460
500
560
615
670
725
830
940
1100
1230
480
540
595
650
705
760
815
880
1040
1200
1340
11
12
13
14
15
16
17
18
22
24
26
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it, in
order to obtain the total height of the insulator (H), please, select the kind of fitting end you have to use and make
the opportune correction with reference to the following table :
Line
fitting
Fitting G
Fitting MG
Fitting VC
Fitting G
Fitting VC
Ground
fitting
Fitting G
Fitting G
Fitting G
Fitting MG
Fitting MG
Code
(2)
GG
MGG
VCG
GMG
VCMG
Height
change (H)
0
+20
+10
+20
+75
isoelectric - Italy
50
06-10
Selection Guide
(Line Voltage, kV)
115
150
220 345
Catalogue
Code ()
ISI-MAX-*
ISI-MAX-*
ISI-MAX-*
ISI-MAX-*
ISI-MAX-*
ISI-MAX-*
ISI-MAX-*
ISI-MAX-*
ISI-MAX-*
ISI-MAX-*
ISI-MAX-*
Specified
Cantilever
Load
kN
15,0
13,5
11,2
11,1
10,2
9,4
8,1
7,7
7,2
6,4
5,7
1035
1155
1275
1395
1515
1635
1875
2115
2475
2775
2955
2600
2900
3300
3700
4100
4450
5200
5950
7100
8090
8600
855
975
1095
1215
1335
1455
1695
1935
2295
2595
2775
340
380
415
450
485
520
615
675
810
855
905
265
300
335
370
405
435
515
575
675
750
780
500
560
615
670
725
830
940
1100
1330
1460
1585
595
650
705
760
815
880
1040
1200
1430
1565
1715
15,5
17,5
18,5
20,0
21,0
22,5
26,5
29,5
34,5
40,0
45,0
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total height of the insulator (H), please, select the kind of fitting end you have to use and
make the opportune correction with reference to the following table :
Line
fitting
Fitting G
Fitting MG
Fitting MG
Fitting VC
Fitting VC
Ground
fitting
Fitting G
Fitting G
Fitting MG
Fitting G
Fitting MG
Code
(2)
GG
MGG
MGMG
VCG
VCMG
Height
change (H)
0
+65
+130
+65
+80
isoelectric - Italy
51
06-10
Selection Guide
(Line Voltage, kV) Catalogue
1101 2002 3003 420 Code ()
70 50 62 765
ISI-BUL-*
ISI-BUL-*
ISI-BUL-*
ISI-BUL-*
ISI-BUL-*
ISI-BUL-*
ISI-BUL-*
ISI-BUL-*
ISI-BUL-*
ISI-BUL-*
ISI-BUL-*
ISI-BUL-*
Specified
Cantilever
Load
(SCL)
kN
27,7
23,3
21,2
19,4
16,3
15,2
13,3
12,2
11,2
10,5
9,0
7,5
n of
Sheds
A
n (1)
13+12
16+15
18+17
20+19
24+23
26+25
30+29
33+32
36+35
39+38
47+46
56+55
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total height of the insulator (H), please, select the kind of fitting end you have to use and
make the opportune correction with reference to the following table :
Line fitting
(Top)
Ground fitting
(Bottom)
Code
(2)
Height
change (H)
Fitting T1
Fitting T2
0
T1T2
Fitting T1
Fitting T1
-30
T1T1
Fitting T1
Fitting T3
+30
T1T3
Fitting T1
Fitting T4
+60
T1T4
Fitting T3
Fitting T3
+90
T3T3
Fitting T3
Fitting T4
+120
T3T4
Fitting T3
Fitting T5
+120
T3T5
Fitting T3
Fitting T6
+170
T3T6
* Please consider the flexibility of the composite insulators
isoelectric - Italy
52
08-10
Please, don't hesitate to contact us directly for obtaining possible explanations or different solutions.
isoelectric - Italy
53
04-2
Selection Guide
Catalogue
17
24
36
45
52
Code ()
ISI-FC-*
ISI-FC-*
ISI-FC-*
ISI-FC-*
ISI-FC-*
ISI-FC-*
ISI-FC-*
ISI-FC-*
2+1
3+2
4+3
5+4
6+5
7+6
8+7
9+8
395
450
510
570
630
690
745
805
390
585
780
975
1170
1365
1560
1755
165
225
285
340
400
460
520
575
70
110
120
150
170
180
200
225
65
100
110
140
155
165
185
210
115
150
180
235
270
285
305
345
160
190
215
270
300
325
355
405
6,5
7,0
7,5
8,0
8,5
9,0
9,5
10,0
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use and
make the opportune correction with reference to the following table :
Line
fitting
Fitting HC
Fitting HC
Fitting HC
Fitting B
Fitting B
Fitting B
Fitting C
Fitting C
Fitting C
Ground
fitting
Fitting GB
Fitting M
Fitting R
Fitting GB
Fitting M
Fitting R
Fitting GB
Fitting M
Fitting R
Code
(2)
HCGB
HCM
HCR
BGB
BM
BR
CGB
CM
CR
Length
change (L)
0
-88
-88
+7
-80
-80
-40
-125
-125
isoelectric - Italy
54
05-1
Selection Guide
(Line Voltage, kV)
72
115
150
Catalogue
Code ()
ISI-FC-*
ISI-FC-*
ISI-FC-*
ISI-FC-*
ISI-FC-*
ISI-FC-*
ISI-FC-*
ISI-FC-*
10+9
12+11
14+13
16+15
18+17
20+19
22+21
24+23
865
985
1100
1220
1335
1455
1575
1690
1950
2340
2730
3120
3510
3900
4290
4680
635
750
870
985
1105
1220
1335
1455
270
310
355
400
435
475
520
560
225
245
285
320
355
390
430
475
450
515
570
625
680
750
820
870
490
550
615
670
735
805
890
940
10,5
11,5
12,5
13,5
14,5
15,5
16,5
17,5
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use and
make the opportune correction with reference to the following table :
Line
fitting
Fitting HC
Fitting HC
Fitting HC
Fitting B
Fitting B
Fitting B
Fitting C
Fitting C
Fitting C
Ground
fitting
Fitting GB
Fitting M
Fitting R
Fitting GB
Fitting M
Fitting R
Fitting GB
Fitting M
Fitting R
Code
(2)
HCGB
HCM
HCR
BGB
BM
BR
CGB
CM
CR
Length
change (L)
0
-88
-88
+7
-80
-80
-40
-125
-125
isoelectric - Italy
55
05-1
Selection Guide
Catalogue
17
24
36
45
52
Code ()
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
2+1
3+2
4+3
5+4
6+5
7+6
8+7
9+8
360
410
470
530
585
645
705
760
340
530
710
900
1100
1280
1470
1660
135
195
255
315
375
435
495
555
65
80
100
125
145
170
190
215
60
75
90
110
130
155
175
200
100
135
160
190
220
255
290
320
145
180
210
240
275
310
340
380
7,0
7,5
8,0
8,5
9,0
10,0
10,5
11,0
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use and
make the opportune correction with reference to the following table :
Line
fitting
Fitting HC
Fitting HC
Fitting HC
Fitting B
Fitting B
Fitting B
Fitting MG
Ground
fitting
Fitting GB
Fitting HB
Fitting G
Fitting GB
Fitting HB
Fitting G
Fitting GB
Code
(2)
HCGB
HCHB
HCG
BGB
BHB
BG
MGGB
Length
change (L)
0
+36
+20
+9
+44
+29
-24
isoelectric - Italy
56
04-2
Selection Guide
Catalogue
72
115
150 230
Code ()
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
ISI-BIG-*
Specified
Cantilever
Load
kN
14,0
12,0
10,8
9,6
8,8
8,0
7,4
6,8
6,0
5,3
4,7
820
940
1060
1175
1290
1410
1525
1645
1880
2115
2350
1800
2200
2600
2900
3300
3700
4100
4450
5200
5950
6700
615
735
855
975
1095
1215
1335
1455
1695
1935
2175
275
310
340
380
415
450
485
520
615
675
760
195
230
265
300
335
370
405
435
515
575
640
420
460
500
560
615
670
725
830
940
1100
1230
480
540
595
650
705
760
815
880
1040
1200
1340
11,5
12,5
13,5
14,5
15,5
16,5
17,5
18,5
22,5
24,5
26,5
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it, in
order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use and make
the opportune correction with reference to the following table :
Line
fitting
Fitting HC
Fitting HC
Fitting HC
Fitting B
Fitting B
Fitting B
Fitting MG
Ground
fitting
Fitting GB
Fitting HB
Fitting G
Fitting GB
Fitting HB
Fitting G
Fitting GB
Code
(2)
HCGB
HCHB
HCG
BGB
BHB
BG
MGGB
Length
change (L)
0
+36
+20
+9
+44
+29
-24
isoelectric - Italy
57
04-2
Selection Guide
(Line Voltage, kV)
115
150
220 345
Catalogue
Code ()
ISI-MAX-*
ISI-MAX-*
ISI-MAX-*
ISI-MAX-*
ISI-MAX-*
ISI-MAX-*
ISI-MAX-*
ISI-MAX-*
ISI-MAX-*
ISI-MAX-*
ISI-MAX-*
Specified
n of Length Leakage Dry arc Power frequency Lightning impul.
distance distance withstand 50-60 Hz withstand 1,2/50 Weight
Cantilever Sheds
L
Load
A
Dry
Wet
posit. negat.
5
kN
mm
mm
kV
kV
kV
kV
n (1)
mm
kg
14,5
13,0
11,6
10,7
9,8
9,0
7,8
7,3
6,9
6,2
5,5
14+13
16+15
18+17
20+19
22+21
24+23
28+27
32+31
38+37
43+42
46+45
1060
1175
1290
1410
1525
1645
1880
2115
2475
2895
2950
2600
2900
3300
3700
4100
4450
5200
5950
7100
8090
8600
855
975
1095
1215
1335
1455
1695
1935
2295
2595
2775
340
380
415
450
485
520
615
675
810
855
905
265
300
335
370
405
435
515
575
675
750
780
500
560
615
670
725
830
940
1100
1330
1460
1585
595
650
705
760
815
880
1040
1200
1430
1565
1715
15,5
17,5
18,5
20,0
21,0
22,5
26,5
29,5
34,5
40,0
45,0
NOTE : Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,
in order to obtain the total length of the insulator (L), please, select the kind of fitting end you have to use and
make the opportune correction with reference to the following table :
Line
fitting
Fitting HC
Fitting HC
Fitting HC
Fitting B
Fitting B
Fitting B
Fitting MG
Fitting MG
Fitting MG
Ground
fitting
Fitting GB
Fitting HB
Fitting G
Fitting GB
Fitting HB
Fitting G
Fitting GB
Fitting HB
Fitting G
Code
(2)
HCGB
HCHB
HCG
BGB
BHB
BG
MGGB
MGHB
MGG
Length
change (L)
0
+36
+20
+9
+44
+29
-24
+12
-4
isoelectric - Italy
58
04-2
isoelectric - Italy
59
04-2
Please, don't hesitate to contact us directly for obtaining possible explanations or different solutions.
isoelectric - Italy
60
04-2
Component insulators
Suspension type
ISI-CAN-A27-120EE
ISI-ROK-A17+16-120EE
ISI-ROK-A18+17-120EE
ISI-ROK-A17+16-120EE
ISI-ROK-A20+19-120EE
ISI-ROK-A21+20-120EE
ISI-CAN-A48-120EE
ISI-ROK-A28+27-120EE
ISI-ROK-A30+29-120EE
Dimensions (mm)
Pollution
Post type
1*
2*
3*
4*
mm/kV
ISI-BIG-A18+17-BHB
ISI-BIG-A24+23-BHB
ISI-MAX-A24+23-BHB
ISI-BIG-A24+23-BHB
ISI-BIG-A27+26-BHB
ISI-MAX-A29+28-BHB
ISI-BIG-A31+30-BHB
ISI-BIG-A38+37-BHB
ISI-MAX-A41+40-BHB
1560
1685
1740
1685
1910
1990
2335
2450
2595
1600
1675
1745
1675
1885
1960
2410
2445
2585
1420
1775
1775
1775
1950
2065
2185
2595
2770
370
680
635
680
695
770
615
1005
1095
55
55
70
55
55
70
55
55
70
35
35
45
35
35
45
35
35
45
55
55
70
50
50
60
45
45
50
5,72
4,42
5,85
4,42
4,22
4,87
3,57
2,90
4,22
> 23
> 31
> 31
> 27
> 31
> 31
> 25
> 31
> 31
Component insulators
Suspension type
ISI-CAN-A27-120EE
ISI-ROK-A17+16-120EE
ISI-ROK-A18+17-120EE
ISI-ROK-A17+16-120EE
ISI-ROK-A20+19-120EE
ISI-ROK-A21+20-120EE
ISI-CAN-A48-120EE
ISI-ROK-A28+27-120EE
ISI-ROK-A30+29-120EE
Dimensions (mm)
Pollution
Post type
1*
2*
3*
4*
mm/kV
ISI-BIG-A18+17-BHB
ISI-BIG-A24+23-BHB
ISI-MAX-A24+23-BHB
ISI-BIG-A24+23-BHB
ISI-BIG-A27+26-BHB
ISI-MAX-A29+28-BHB
ISI-BIG-A31+30-BHB
ISI-BIG-A38+37-BHB
ISI-MAX-A41+40-BHB
1400
1490
1550
1490
1675
1735
2125
2155
2280
1600
1675
1745
1675
1885
1960
2410
2445
2585
1445
1800
1800
1800
1985
2105
2225
2645
2825
655
965
930
965
1040
1125
1015
1420
1530
50
50
65
50
50
65
50
50
65
35
35
45
35
35
45
35
35
45
55
55
70
55
55
70
55
55
70
5,50
4,20
5,60
4,20
4,00
4,60
3,30
2,70
4,00
> 23
> 31
> 31
> 27
> 31
> 31
> 25
> 31
> 31
Component insulators
Suspension type
ISI-CAN-A27-120EE
ISI-ROK-A17+16-120EE
ISI-ROK-A18+17-120EE
ISI-ROK-A17+16-120EE
ISI-ROK-A20+19-120EE
ISI-ROK-A21+20-120EE
ISI-CAN-A48-120EE
ISI-ROK-A28+27-120EE
ISI-ROK-A30+29-120EE
Post type
ISI-BIG-A18+17-BC
ISI-BIG-A24+23-BC
ISI-MAX-A24+23-BC
ISI-BIG-A24+23-BC
ISI-BIG-A27+26-BC
ISI-MAX-A29+28-BC
ISI-BIG-A31+30-BC
ISI-BIG-A38+37-BC
ISI-MAX-A41+40-BC
Dimensions (mm)
Pollution
1*
2*
3*
4*
mm/kV
1555
1680
1735
1680
1905
1985
2330
2445
2590
1600
1675
1745
1675
1920
1990
2410
2445
2585
1435
1788
1790
1790
1965
2080
2200
2610
2795
385
695
650
695
710
785
630
1020
1110
55
55
70
55
55
70
55
55
70
35
35
45
35
35
45
35
35
45
55
55
70
50
50
60
45
45
50
----------
> 23
> 31
> 31
> 27
> 31
> 31
> 25
> 31
> 31
Component insulators
Suspension type
ISI-CAN-A27-120EE
ISI-ROK-A17+16-120EE
ISI-ROK-A18+17-120EE
ISI-ROK-A17+16-120EE
ISI-ROK-A20+19-120EE
ISI-ROK-A21+20-120EE
ISI-CAN-A48-120EE
ISI-ROK-A28+27-120EE
ISI-ROK-A30+29-120EE
Post type
ISI-BIG-A18+17-BC
ISI-BIG-A24+23-BC
ISI-MAX-A24+23-BC
ISI-BIG-A24+23-BC
ISI-BIG-A27+26-BC
ISI-MAX-A29+28-BC
ISI-BIG-A31+30-BC
ISI-BIG-A38+37-BC
ISI-MAX-A41+40-BC
Dimensions (mm)
Pollution
1*
2*
3*
4*
mm/kV
1555
1680
1735
1680
1905
1985
2330
2445
2590
1600
1675
1745
1675
1920
1990
2410
2445
2585
1450
1805
1805
1805
1980
2095
2215
2625
2810
400
710
665
710
725
800
645
1035
1125
50
50
65
50
50
65
50
50
65
35
35
45
35
35
45
35
35
45
55
55
70
55
55
70
55
55
70
----------
> 23
> 31
> 31
> 27
> 31
> 31
> 25
> 31
> 31
* Maximum load are for single loads in the specified direction: 1=Vertical, 2=Tension, 3=Compression, 4=Longitudinal
Please, don't hesitate to contact us directly for obtaining possible explanations or different solutions.
isoelectric - Italy
61
04-2