Sei sulla pagina 1di 2

Nurse Call

MASTER

SUB

1 120 NEM
Lamp memory intercom: Subs call-in with
tone & light, staying
Press-to-talk or handset auto voice actuation
Selective, group of 10 subs or All call.
Press-to-talk communication

Call button & corridor lamp for subs area.

Press-to-talk & handset communication

Options

NB-L
Ceiling

NA-T/A
Handset sub

NBY-1A
Metal jack for NBR-8A
NBR-8A
Bedside call switch

*NBY-4AS, NBR-7AS-S: SOP (Special Order Products)

System components
Master stations

Master stations

NAR-2A

NB-L

NBR-7AS

red
black
green
blue
orange
org/wht

NBY-1A
Blue(2)

NAR-2A
NBY-4A

2
NEM-40A/C

S
S
+
-

NAR-2A NBR-8A

1
E

NBY-4A

(max. 3 NBR-7AS's
in parallel)

NEM-10/C, NEM-20/C
NEM-30/C, NEM-40/C
NEM-10A/C, NEM-20A/C
NEM-30A/C, NEM-40A/C

IER-2

H
140
140
176
176

PS24

D (mm)
260
260
260
260
NA-T/A

Output

Wiring

NBR-8A
15

47.5

142

Distance
NEM to NA subs

74

K 1 common + no. Subs


94

105

23

Specifications (NEM-40A/C)

Power supply
Communication

W
346
496
446
596

70

43

Power source

596

NA-A/AN

NB-L

PS24 : PS-24E

86

446

496

180

346

to NBR-7AS
red
black
green
blue

NBY-1A

NBY-4A

140

176
140

NEM-40A/C

NBR-7AS
NB-L

NBY-4A
2

70

NEM-40/C

2
E
31
32
33
34
35
36
37
38
39
40

NBY-4A, Corridor light


NAR-6A, Call button
NBR-7AS, Bathroom pullcord,
moisture-resistant

232

NA-NE

NA-A/AN

Blue
(2)

NBY-1A, Metal jack for NBR-8A


NBR-8A, Bedside call button
NAR-2A, Call reset button
NAR-3, Round corridor light

260

NA-A/AN

Health care accessories

red
black
green
orange
org/wht
blue

24V DC, 45W max. 2.5W standby


(NEM-40/C)
PS-24E
Sub calls in w/tone & LED staying at master.
Press TALK button to transmit, release to
listen, or lift handset. At sub, pretone and
voice upon selected. Talk handsfree. Press
ALL CALL button to activate all subs'
speaker.
500mW max., adjustable.
All Call: 6W, 12W.
Selectively up to 10 subs w/TALK: 3W
2 wires per sub, non-twisted (1 common +
no. Subs)
0.65mm
0.8mm
130m
200m

NURSE CALL

NURSE CALL

NBY-4A

NBY-1A

115

A
B
C
D
E

55

68

NAR-6A
NAR-2A

260

A
B
C
D
E

160

NB-L, Ceiling
NA-NE, Flush-mount

83.5

Corridor lamp

70

NA-A, Desk/wall
NA-AN, Desk/wall w/privacy
NA-T/A, Handset sub

169

Tone & LED

NA-NE

Sub stations

E
1
2
3
4
5
6
7
8
9
10

NEM-40A/C

NA-A

NBY-4A

Press-to-talk/handset
NEM-10A/C
NEM-20A/C
NEM-30A/C
NEM-40A/C

83.5

NA-A

Press-to-talk
NEM-10/C
NEM-20/C
NEM-30/C
NEM-40/C

220

NEM-40A/C

Selective
call
One sub or
group of 10.

NA-NE

Capacity
10-call
20-call
30-call
40-call

All call

Call switching device


NBJ-20, for NEM-10/C ,20/C
NBJ-40, for NEM-30/C, 40/C
NBJ-20B, for NEM-10A/C, 20A/C
NBJ-40B, for NEM-30A/C, 40A/C P.89

NBR-7AS
Bathroom pullcord,
moisture-resistant
*NBR-7AS-S: for patient room

83.5

Communication network & wiring

NAR-2A
Call reset
button

82

NA-AN, desk/wall sub


w/privacy

IER-2
Call extension
P.96

120

NEM-30A/C, 30-calll master


NEM-40A/C, 40-calll master

NA-NE
Flush aluminum
panel

NEW-5
Dual-master call
adaptor for NEM-n(A)/C
(n=10, 20, 30, 40) P.89

185

NEM-30/C, 30-calll master


NEM-40/C, 40-calll master

NA-A, desk/wall sub

120

NEM-10A/C, 10-calll master


NEM-20A/C, 20-calll master

NAR-6A
NBY-4A
NAR-3
Call button Corridor light Round corridor
light
*NBY-4AS:
for 4~8 subs

83.5

NEM-10/C, 10-call master


NEM-20/C, 20-calll master

NB-U
Music adaptor
P.89

87

Nurse Call
Music adaptor
USED FOR

FEATURES

SPECIFICATIONS

NEM-n/C, NEM-nA/C
(n = 10 ~ 40)
NEM-n(A)/7.A (n = 50 ~ 120)

Distributes music to all subs with


auto cutout while communicating.

Power source: 6V DC, supplied by


NEM.
Permitted input: 5W. 10W at its peak.
Wiring:
3 wires common + 2 per
10-call (max. 11).

WIRING

Options

NEM-40A
1
2
3
4
5
6
7
8
9
10

To sub
stations

NB-U
IER-2
Call extension
speaker
P.96

When NEM employs NEW-5


adaptor(s), NB-U can not
be used.

40

NB-U

B
Y

B
Y

A1
V1

A1
V1

A2
V2

A2
V2

A3
V3

A3
V3

A4
V4

A4
V4

BGM

Communication network & wiring


Selective or Group Call
NEM-40A/C

All Call
Selective or Group Call

NA-A

NBR-7AS-S

Multi-Station Patient Room

Bathroom pullcord
in a Patient Room
NEM-40A/C

Master stations, 50~120-call (in 10-call steps)


NEM-50~120:
Press-to-talk master (w/control adaptor)
NEM-50A~120A: Press-to-talk/handset master (w/control adaptor)
NA-A:
Sub station, desk/wall NA-NE: Flush mount
NA-AN: Desk/wall, privacy
NB-L:
Ceiling mount
NA-T/A: Handset sub
Health care accessories
NBY-1A: Metal jack panel for NBR-8A
NBR-8A: Bedside call button
NAR-2A: Call reset button
NAR-3:
Corridor call light
NBY-4A: Corridor call light
NBY-4AS: for 4~8 sub-patient room (SOP)
NAR-6A: Call button panel
NBR-7AS: Bathroom call pullcord
NBR-7AS-S: for patient private bathroom (SOP)

USED FOR

FEATURES

NEM-n/C, NEM-nA/C
(n=10~40)

Common NA subs place a


call ringing two NEM masters.

NA-A, AN, NE

Blue
NBY-4A

ea.2
NA-A

* NEW-5 can not be used


w/NEM-n, NEM-nA
(n= 50~120)

NBY-1A

A
E

Blue

A
B
C
D
E

A
B
C
D
E

A
B
C
D
E

A
B
C
D
E

NBY-4AS
(SOP)

Communication
Blue (2)

Remove the D-E link


on each sub station.

NAR-2A

PS24 : PS-24E (for 10~40 subs).


NBR-7AS-S (SOP): Call-in from NBR-7AS-S cannot be cancelled with
NAR-2A Call reset button. Press on upper end of Call button on
NBR-7AS-S to release the call.

Output
All call
Group call
Wiring
Distance
NEM to subs

A
E
A
E

A
E

Distance:
NEW-5 to sub
NEW-5 to NEM

0.65mm 0.8mm
130m
200m
100m
150m

A
E
36
37
38
39
40
E
H
Y
Q

MA1
MA2
MA3
MA4
MA5
MAE
MAH
MAY
MAQ

+
-

260

Power source
Power consumption
Call-in

A
E

+
-

MB1
MB2
MB3
MB4
MB5
MBE
MBH
MBY
MBQ

36
37
38
39
40
E
H
Y
Q

1S
1E

A
E

2S
2E

A
E

3S
3E

A
E

4S
4E

A
E

5S
5E

A
E

+
-

PS24
PS12

PS24

:PS-24E
:PS-12A, PS-12B

Call switching device NBJ, NBJ-B


95

Specifications (NEM-120A)

Blue

88

40

12V DC.
PS-12A, PS-12B
5 subs per NEW-5.
Max. 8 adaptors
for NEM-40(A)/C.
Communication: Separate channel for
ea. master.
Wiring:
2 wires,
NEW-5 to sub.

NA-A

* NEM-n width: each 100mm less

340

A
E

A
E

NA-A, AN, NE
ea.2
NA-A

36

PS12

Blue (2)

NA-A,
NA-AN

4+1 indiv.

746
896
1046
1196

Blue (2)

NEM-40A

A
E

PS24

211

NAR-2A

PS24

4+1 indiv.

A
E

NEW-5

NEW-5

Power source:
Power supply:
Capacity:

220V AC, 50/60Hz.


Max. 180W. 7.5W standby (120-call)
Intermittent tremolo & LED, staying.
Pre-tone & voice direct at sub
Press-to-talk or handset voice
actuation at NEM. Handsfree at sub.
500mW at NEM & subs
24W output w/ALL CALL sw.
3W output per 10 subs w/TALK sw.
2 wires per sub (1 common + 1)
0.65mm
1.0mm
130m
300m

USED FOR

FEATURES

NBJ-20 for NEM-10/C & NEM-20/C


NBJ-40 for NEM-30/C & NEM-40/C
NBJ-20B for NEM-10A/C & NEM-20A/C
NBJ-40B for NEM-30A/C & NEM-40A/C

Switches all NA sub wiring from one master to the other to


route all call-ins to the master on duty.
NBJ-20 & NBJ-20B are equipped with a rotary switch, and
NBJ-40 & NBJ-40B with two rotary switches.
When the rotary switch is put to 1 position, all the subs wiring
is connected with Master station(M1). To switch the sub
wiring to Master station (M2) at a time, put the rotary switch to
2 position.

WIRING
NEM-20/C

NEM-20/C

1 2 3 4 ... n E

1 2 3 4 ... n E

1 2 3 4 ... n E
M1

1 2 3 4 ... n E
M2

NURSE CALL

NURSE CALL

Red
Black
Green
X
Blue
Orange
Org/whit
Cut GREEN.

Blue

11
12
13
14
15
16
17
18
19
20

NEM-40A

NB-L
NBR-7AS-S
(SOP)
Red
Black
Green
Blue
Orange

SPECIFICATIONS

WIRING

176
140

NEM-60A~NEM-120A

Twisted AMP.

Remove a jumper between A1~V1,


A2~V2, A3~V3, A4~V4 on master
station.
Amplifier requirements: Input: 100mV
for rated output. 10W w/8 output or
10W w/4~16 output.
Do not use 1K output on the amplifier.

Dual-master call adaptor

E
1
2
3
4
5
6
7
8
9
10

MUSIC
SOURCE

OUTPUT
8

System components

NB-L

Receive a call with


tone & LED staying

NB-U
Music adaptor
P.89

Notes:

NEM-60A
60-call master

Distance:
0.65mm 0.8mm
NB-U to NEM
10m
15m
NB-U to Amp.
75m
115m

NBJ-40

S
1 2 3 4 ... n E M
NBJ-20 or
NBJ-20B (*)
To sub stations

(*): Terminal M remains unused.

89