RATING
Nominal Volume (L)
Net Volume (L)
Payload (Kg) (LNG)
43400
41230
17440 Kg
Length (mm)
Width (mm)
Height (mm)
MAWP (kPa) Bar
-Voidage (Ullage)
12'192
2'438
2'591
10 Bar
Min 5%
(145 PSIG)
TANK
Inner Vessel
Material
Working Pressure
Design Code
Inspection Authority
Baffles
Material of construction
Design Temperature Range
Outer Jacket
Material
Design Code
Material of construction
Internal Design Pressure
External Design Pressure
Design Temperature Range
Carbon Steel
EN 13530 & ASME & TPED
EN 10210 S355 J2H / Supraform TM
-1,0 bar
1,0 bar
-20 to +50 C
April 2011
Page 1 of 5
PRODUCT SPECIFICATION
CRYO CONTAINERS (Pty) Ltd
TIL 43000-04 GC LNG
(T75 ASME, 10 BAR)
Integral Reinforced
EN 10210 S355 J2H / Supraform TM 380
EN 10025 S355 K2G3C / Supraform TM
380
EN 10025 S355 K2G3
Carbon Steel - SABS 300 WA
(L) 12 192 x (H) 2 591 x (W) 2 438
36 000 kg
12 000 kg
Flow diagram
Pipe Material
Pipe Sizes
Pipe Sizes
Pipe Sizes
Instrumentation Pipes
Valves
Trycocks
Instrumentation
Differential Pressure Gauge
(one)
Pressure Gauge (One)
Fittings
120 - 160m/hr
75 - 100 scfm
(or as specified by Customer)
Stainless steel upwards opening hinged
door compartments.
April 2011
Page 2 of 5
PRODUCT SPECIFICATION
CRYO CONTAINERS (Pty) Ltd
TIL 43000-04 GC LNG
(T75 ASME, 10 BAR)
VESSEL TEST
Inner Vessel
Outer Jacket
5.
PAINTING
First coat
Intermediate coat
Final coat
April 2011
Page 3 of 5
PRODUCT SPECIFICATION
CRYO CONTAINERS (Pty) Ltd
TIL 43000-04 GC LNG
(T75 ASME, 10 BAR)
7.
IMDG - T75
RID/ADR T75
Additional Approvals:
TIR/Customs
CSC
UIC (34000kg with a super heavy decal)
TC Impact Approved
TPED
US DOT
DOCUMENTATION
The following documentation will be provided:
Certificate of cleaning (placed in the document holder).
Initial Inspection Certificate for each tank.
Name plate details.
List of transportable products.
April 2011
Page 4 of 5
PRODUCT SPECIFICATION
CRYO CONTAINERS (Pty) Ltd
TIL 43000-04 GC LNG
(T75 ASME, 10 BAR)
PRODUCTS
UN1971 Natural Gas, refrigerated liquid.
UN1073 Oxygen, refrigerated liquid.
UN1951 Argon, refrigerated liquid.
UN1977 Nitrogen, refrigerated liquid
UN NO 1038 Ethylene, refrigerated liquid
9.
OTHER
Walkways
Ladder
Earthing Connection
Document Holder
Customs Sealing
Decals
Data Plates
Valve Cabinet
Baffles
Not required.
Not required.
1-off stainless steel lug 60 x 50 x 2,5mm
with a 20mm hole, is located at the rear of
the tank frame.
1-off clear PVC document holder is
provided. The holder is water-resistant and
is fitted on the left lower rear of frame.
Discharge valves and relief valves are
provided with customs sealing devices.
One set per tank as per code
requirements. Owner logos supplied client,
and applied by manufacturer.
One set of stainless steel data plates per
tank as per code requirements.
A valve protection cabinet, complete with
hinged door, houses the gas and liquid line
valves pressure gauge and thermometer.
Five sets of stainless steel plate baffles are
fitted.
April 2011