Sei sulla pagina 1di 64

In A State Of Pleasant Surprise

www.minilecgroup.com

When we promise, we

deliver.

We change with the changing markets;


we bring in changes that change the markets.

We respond to customer feedback.

No wonder our
customers remain in
a permanent state of

pleasant surprise!

We are Minilec
Starting operations in 1965 as a
manufacturer of single phasing preventors
(phase failure relays), Minilec is today a
leading group involved in 100% indigenous
production, marketing and export of reliable
industrial electronic products for protection,
control and monitoring.

Market leader in India


for protection relays,
monitoring relays and
alarm annunciators!

World's only company


manufacturing
a very wide range of
products in diverse
Protection, Control &
Monitoring areas !

Index

Expanding rapidly by
spreading our wings
globally and continuously
introducing new product
categories!

02

THE MINILEC GROUP


SHAPING THE MARKETS
PROGRESS
QUALITY FOCUS
PRODUCTS
CUSTOMERS

03
04
05
06
07
08

Our insistence on quality has resulted in


customer insistence for our products. Our
continuous effort to introduce new features
to enhance product performance, adapt new
technology to bring in greater sophistication
and evolve new products in anticipation of
market needs gives our customers many
reasons to remain in a permanent state of
pleasant surprise

PRODUCT DETAILS
Phase Failure Relays
Monitoring Relays
Motor / Pump Protection Relays
Electronic Timers
Liquid Level Controllers
Power Line Transducers
Automation Products
Alarm Annunciators
Other Products

09 - 14
15 - 22
23 - 28
29 - 32
33 - 36
37 - 40
41 - 44
45 - 55
56

Soft Starters
Agri Sector Product
Pune-the city of Minilec

57 - 60
61 - 63
64

THE MINILEC GROUP


ORGANISATION
The Minilec Group is a progress-oriented organisation incorporating four group companies.
Group companies work on niche areas to ensure an 'activity focus'. The group is very well-knit and
works together keeping the larger picture in sight.
Minilec (India) Pvt. Ltd. A world-class manufacturer and exporter of microprocessor-based alarm
annunciators, pre-programmed logic controllers, diesel level controllers, motor/pump protection
relays, thermistor-based winding protection relays etc.
Minilec Protective Relays Pvt. Ltd. Manufacturer of a variety of protection relays

NETWORK & CUSTOMER


SUPPORT
Minilec has a strong sales and
service network in the country
which, along with an extensive
dealer network, ensures
reliable and prompt after-sales
service. We also have a wide
base internationally.

Minilec Singapore Pte. Ltd. The S-E Asia marketing wing


Shalaka Electronics Pvt. Ltd. For export of Minilec products

Russia

Canada
UK
France

Holland
Germany

Spain

U.S.A.

Mexico
El Salvador
Venezuela
Guyana
Colombia

Ghana

Greece
Korea
Syria
Lebanon
Pakistan
Kuwait
Nepal
Jordan
Bangladesh
Egypt
Taiwan
Bahrain Qatar
UAE
Hongkong
Saudi Arabia
Thailand Vietnam
Oman
Philippines
Yemen
Malaysia
Sri Lanka
Congo
Kenya
Singapore

Italy

Indonesia

Australia
South Africa

Factory & Head Office


Regional Offices

New Zealand

Resident Engineers

03

SHAPING THE MARKET


BENCHMARK
DEVELOPMENTS
1965-2007

1965:

First to design and


manufacture single
phasing
preventors in
India and fulfill an
emerging market
requirement innovatively.

Minilec's bench-mark developments have shaped the markets since


1965.For instance, in the year 2002, responding to customer feedback,
we introduced multiple options in enclosures of relays, ( in addition to the
existing D1-D2 ), P1-P2 and F3 enclosures. This product enhancement
gave our customers the much needed flexibility in terms of size and
started a trend. Another interesting product development came
anticipating a market need, the MBAS 9400 with front replaceable
windows, which gave us the edge to win a major tender from Indonesian
Electricity Authority against American and Japanese competitors in 1994.
This updation in MBAS 9400 has also ensured a continuous flow of
orders from the Malaysian Electricity Authority since 1994.

1994:

First company in
our segment to
get ISO 9001.

1982:

1997:

First to launch
micro-processor
based alarm
annunciator.

First company to
introduce RS232
communication
port to alarm
annunciators.

(Redesigned as Microwarn
9000 in 1990), this was, and
remains the most beautiful
alarm annunciator attracting
customers across the globe.

1984:

First to
introduce super
bright LEDs for
facia of alarm
annunciators.

2000:

Millennium
Series (P1 & P2
enclosures)
products launched

Microcontroller
based relays replacing
existing relays (D1 & D2 series)
introduced.

2007:

S2 (Sleek) Series
products with
microcontroller & SMD
technology launched.
This technology has the powerful
advantage of added intelligence. State
of art SMD technology &
microprocessor based design gives
higher reliability, multi purpose
functionality, reduced size & more
value.

2007-08:
2005:

1987:

First to launch
prodless dry run
protection device
pump guard.
This innovation alone, won
us several new customers
globally.

04

2006:

MBAS 9700
expanded up to
128 channels.

Innovative and upgraded


new products with latest
technology are poised to
change the face of the
emerging market in
India and abroad.

PROGRESS

Every small change or a big expansion that serves the customer better
is progress. To us at Minilec, one more pleasant surprise for our
customers is progress.
This progress is evident in every area, be it figures of turnover and
exports or developments in infrastructure, products and R&D.

INFRASTRUCTURE

40,000 sq.ft Premises

200+ Employees

located in clean, green and environment friendly location at


Pirangoot Industrial Estate near Pune, includes 10,000 sq.ft of
recent addition.

Highly qualified engineers, R&D experts, quality control


technicians and administrative staff; all very well-trained to
ensure high quality results.

Sophisticated R&D laboratory

Well-calibrated testing equipments

Manufacturing facility to cater


ever-growing customer demands

Innovative designs are made here.

05

QUALITY FOCUS
QUALITY SYSTEMS

ACCREDITATIONS

Stringent quality checks by carefully selected


vendors, extensive inward inspection and proven
production processes continuously improve
product quality at Minilec. Minilec's Quality
Systems are verified by BVQI to be as per ISO
9001 requirement of international quality
standards.

The Models of phase failure


relays and alarm annunciators
carry CE mark and CSA
Certification.

The products are also thoroughly type tested at


reputed test houses in India, Singapore, Malaysia
and Russia as per the IEC standards.

YEARS
WARRANTY!

All Minilec alarm


annunciators carry a
5 years' warranty.

'Timely supply of
reliable products with
innovative features for
customer satisfaction.'
Quality Policy of Minilec

06

PRODUCTS
WIDEST RANGE
Minilec is the only company
in the world offering the
widest range of products in
all three product segments
viz. protection, control and
monitoring.
Our products cater to every
agro. and industrial
segment and provide for
the needs of small scale
industries as well as
corporate giants like
Siemens and Reliance.

PRODUCT CATEGORIES
Phase Failure Relays
Voltage / Current / Frequency /
Power Monitoring Relays
Motor/Pump Protection Relays
Level Controllers
Timers
Alarm Annunciators
Power Line Transducers
Pump Automation Products
Soft Starters
Process & Plant Controllers
SCADA Systems

TREND-SETTING DESIGNS
Our product designs today set the
trends for the markets in India.
Minilecs quality is a standard that
even competitors aspire for. Our
products are approved by leading
industrial project consultants.
Growing demand for our products
world-wide is a proof of customer
acceptance for our products
globally. Our products are rated as
'being the best' on the three
criteria of Quality, Product
Features and Delivery Schedules.

SECTOR DIVERSIFICATION

Omnipresence of our products


across agro and industrial sectors.

20 %
Farm Irrigation

10 %
Water Supply
& Sewerage

10 %
Process Industry

15 %
Air Conditioning
& Refrigeration

5%
Material Handling

5%
Machinery & Equipments

20%

15%
Telecommunication

Power Generation,
Transmission & Distribution

THOROUGH APPROACH TO PRODUCT RELATED EDUCATION


We update our customers & dealers about our latest product range and
breakthrough technology through various seminars, training sessions
and regular product literature . This ensures optimum utilization of the
latest features and technology used in products.
07

Million $
9.50

UNDETERRED GROWTH

Estimated

3800
3600
3400

2800

7.50

Yearly Sales Growth

7.00

Growing turnover is also an index of product


reliability & increasing customer satisfaction.

2600
2400

Turnover in INR x 100,000

Turnover has
shown a steady
increase. Even in
times of market
lows, Minilec has
never found it
difficult to keep a
growing turnover
trend.

8.50
8.00

3200
3000

9.00

6.50
6.00

2200

5.50

2000

5.00

1800

4.50

1600

4.00

1400

3.50

1200

3.00

1000

2.50

800

2.00

600

1.50

400

1.00

200

0.50

0
07
-0
8

84
-8
5
85
-8
6
86
-8
7
87
-8
8
88
-8
9
89
-9
0
90
-9
1
91
-9
2
92
-9
3
93
-9
4
94
-9
5
95
-9
6
96
-9
7
97
-9
8
98
-9
9
99
-0
0
00
-0
1
01
-0
2
02
-0
3
03
-0
4
04
-0
5
05
-0
6
06
-0
7

0.0

Estimated

6.0
5.5

Turnover in US$ x 100,000

5.0

EXPORTS :

4.5

Exports rose steadily in the initial years, and are now

4.0

showing a rapid growth fueled by a very encouraging

3.5
3.0

reception of our products globally. Minilec has traditionally

2.5
2.0

exported to S.E. Asia, Europe and the Middle-East.

1.5

Exports to North and South America are now increasing

1.0
0.5

substantially.
07
-0
8

05
-0
6

03
-0
4

00
-0
1

98
-9
9

95
-9
6

93
-9
4

0.0

CUSTOMERS

Minilecs customers span a wide spectrum of


segments and scale.

SIEMENS

BLUE STAR

Repeat orders from customers for decades is a very


big confirmation of customer delight with our
products.
Crompton
Greaves

OHPC

li

TM

08

PHASE FAILURE RELAYS


These relays are suitable for monitoring incoming 3-phase supply
from Mains (Electricity distribution line). Being independent of
load, they can be used for any HP/KW rating of load.

MODELS

FEATURES

PROTECTIONS / FUNCTIONS

VSP D1, VSP D2,


P1PF S1, P1PF S2,
P2PF S1, S2 VMR1,

Phase Failure (Phase Loss / Single


Phasing),
Phase sequence reversal,
Voltage Unbalance,
Under Voltage,
Over Voltage

S2 VMR2, HLS D2,


HLV D2, ALV D2,
VST D1, P2 PFV1,
F3 PFV1, D2 VMR1,
D2 VMR2, S2 VMR3

Fixed/adjustable unbalance
settings
Fixed/adjustable undervoltage/over-voltage settings
Fixed/adjustable trip delays
Built-in or external power supply
Resetting Auto or Manual
Output contacts : 1 CO or 2 CO
Choice of enclosures (DIN-Rail,
Plug-in, Flush)
Models with Micro-Controller
based design
Use of SMD Technology
User-friendly LED indications

Ordering Instructions

Product Family Name


Model Name
System Supply Voltage
Aux. Supply / Control supply
voltage
09

P H A S E F A I L U R E R E L A Y S

Wherever not specified


Contact Rating :
5A @ 230 V AC
(resistive)
* Available on request.

P1 PFS1
Phase Sequence Relay

Phase Failure, Unbalance,


Phase Sequence,
Auto Reset, Fixed Unbalance
Setting,
1 CO output Relay

Phase Failure, Unbalance,


Phase Sequence,
Auto / Manual / Remote Reset,
Adjustable Unbalance setting,
2 CO output relay

Phase Sequence,
Phase Loss Auto Reset,
1 CO output relay

110/240 / 380 / 415 V AC 20% 50 / 60 Hz

110/240 / 380 / 415 V AC 20% 50 / 60 Hz

110 / 240 / 380 / 415 V AC 10%, 50 / 60 Hz

110 / 240 / 380 / 415 / 440 V AC 20%


1 CO

110 / 240 / 380 / 415 V AC 20%


2 CO

Built-in
1 CO (Pick-up on correct phase sequence)

Yes
40 V 6 V (fixed)
N.A.

Yes
30 V to 70 V 6 V (adjustable)
N.A.

Yes
N.A.
N.A.

3.5 sec. 1.5 sec.

3.5 sec. 1.5 sec.

N.A.

Auto
320 gms.

Auto / Manual / Remote


400 gms.

Auto
175 gms.

76 x 30.5 x 117.5
68 centre to centre / 35 mm rail Mounting

76 x 56.5 x 117.5
67 x 46
/ 35 mm rail Mounting

50 x40 x 80
8 - Pin Plug-in

Aux
Supply

Aux
Supply
RYB

R B Y

R B

Phase Fail

16
18

15

R B

L2
L3

OFF

N/V

L1

L2

L3

OFF

ON
N/V

DOL STARTER

Y
B

ON

DOL STARTER

1 2 3 4 5 6
1

VSP D2

VSP D1

AUX.
SUPPLY

AUX.
SUPPLY
7

7 8 9 10 11 12

13 14 15 16 17 18

Bottom view

Relay contact position shown in 'Power on' (Healthy) condition


10

3
1

13 14 15

R Y B

L1

R
Y

R B Y

3 Ph

R Y B

Td : 2-5 Sec.

15

13

Td : 2-5 Sec.

16

14

13

13

R B Y

Phase Fail

3 Ph
17

3 Ph

RYB
RYB

R Y B

14

Resetting Mode
Weight
Dimensions (mm)
Overall (L x W x D)
Mounting (L x W)

VSP D2
Phase Failure Relay

13

Supply Voltage
System
Auxiliary
Output Contacts
Trip Setting (Volts)
Phase Sequence
Phase Unbalance
UV/OV
Trip Time Delay
On Phase Failure/Sequence

VSP D1
Phase Failure Relay

P H A S E F A I L U R E R E L A Y S
P1 PFS2

P2 PFS1

S2 VMR1

S2 VMR2

Phase Failure Relay

Phase Failure Relay

Phase Failure Relay

Phase Failure Relay

Phase Failure, Unbalance,


Phase Sequence,
Auto reset, fixed unbalance
setting,
1 CO output relay

Phase Failure, Unbalance,


Phase Sequence
Auto reset, Adjustable
Unbalance setting,
2 CO output relay

US

US

Microcontroller design, SMD


Technology,
Phase Failure, Unbalance, Phase
Sequence, under voltage, Over
Voltage
Auto reset, Fixed Unbalance
setting, Fixed UV/OV settings,
2 CO output relay

Microcontroller design,
SMD Technology
Phase Failure, Unbalance,
Phase Sequence
Auto reset, Adjustable
Unbalance setting,
2 CO output relay

110 / 240 / 380 / 415 V AC 10%, 50 / 60 Hz

240 / 380 / 415 V AC 15%, 50-60Hz

100-120 / 220-240 / 380-440V AC 20%, 48-63 Hz

100-110-120 / 220-230-240 / 380-415-440V AC 20%, 48-63 Hz


Selectable by Front Knob

Built-in
1 CO

Built-in
2 CO

Built In (from 3 Phase)


2 CO

Built In (from 3 Phase)


2 CO

Yes
40V 6V (fixed)
N.A.

Yes
30 V to 70 V 6V (adjustable)
N.A.

Yes
4 % TO 20 % (Variable) 5% of full scale.
N.A.

Yes
10% (Fixed) 10%
20% (Fixed)

3.5 sec. 1.5 sec.

1 - 5 secs. (variable)

4 Sec 1 Sec / RP-Instant

2 - 5 Sec. (Fixed) / RP-Instant

Auto
175 gms.

Auto
250 gms.

Auto/ Manual Reset (Selectable by Front Push Button)


100 gms (Approx.)

Auto Reset
100 gms (Approx.)

50 x40 x 80
8 - Pin Plug-in

80 x 35 x 95
11 - Pin Plug-in

30 X 60 X 90
35 mm Rail Mounting

30 X 60 X 90
35 mm Rail Mounting

RYB

R B Y

3 Ph

R Y B
RYB
RYB

R B

R Y B

RYB

Unbalance
>30 - 70V set value
or Reverse phase

11

3 Ph

11

R
Y
B

10

10

R Y

OV

R B Y
UV
Td : 2-5 Sec.

Td : 3-5 Sec.

11

RY
Unbalance /
Phase fail

R B Y

3 Ph

Td : 2 to 5 Sec.

R B Y

3 Ph

Td : 2-5 Sec.

R B

Phase Fail
/Reverse

Td : 2-5 Sec.

Unbalance
>4 - 20 %

12

10

10

11

12

R
Y
B

7
1

Bottom view

4
3
2

6 7
8
9
10

11

Bottom view

Relay contact position shown in 'Power on' (Healthy) condition

Relay position shown in 'Power off' condition


11

P H A S E F A I L U R E R E L A Y S
HLS D2

HLV D2

ALV D2

Phase Failure with UV / OV Relay

Phase Failure with UV / OV Relay

Phase Failure with UV / OV Relay

Phase Failure, Unbalance,


Phase Sequence,
under voltage, Over Voltage
Auto reset, Fixed Unbalance
setting, Fixed UV/OV settings,
2 CO output relay

Phase Failure, Unbalance, Phase


Sequence,
under voltage, Over Voltage
Manual reset, Fixed Unbalance
setting, Adjustable UV/OV settings,
2 CO output relay

Phase Failure, Unbalance,


Phase Sequence, under voltage,
Over Voltage
Auto Reset, Fixed Unbalance
setting, Adjustable UV/OV
settings,
2 CO output relay

240 / 380 / 415 / 440 V AC 20% 50 / 60 Hz


110 / 240 / 380 / 415 / 440 V AC 20%
2 CO

240 / 380 / 415 / 440 V AC 20% 50 / 60 Hz


240 / 380 / 415 / 440 V AC 20% 50 / 60 Hz
110 V (Fixed) or (220 - 230 - 240) or (380 - 415 - 440) V AC 20% selectable
2 CO
2 CO

Yes
40 V 6 V (fixed)
85% 5 V (fixed)
110% 5V (fixed)

Yes
40 V 6 V (fixed)
80% to 95% (adjustable)
105% to 120% (adjustable)

Yes
40 V 6 V (fixed)
80% to 95% (adjustable)
105% to 120% (adjustable)

3.5 secs. 1.5 sec

Supply Voltage
System
Auxiliary
Output Contacts
Trip Setting (Volts)
Phase Sequence
Phase Unbalance
Under Voltage
Over Voltage
Trip Time Delay
On Phase Failure
On UV/OV
Resetting Mode
Weight
Dimensions (mm)
Overall (L x W x D)
Mounting (L x W)

Wherever not specified


Contact Rating :
5A @ 230 V AC
(resistive)
* CE marked products
available on request.

3.5 secs. 1.5 sec


Less than 2 secs.
Auto
400 gms.

Manual / Remote
430 gms.

3.5 secs. 1.5 sec


Less than 2 secs.
Auto
400 gms.

76 x 56.5 x 117.5
67 x 46
/ 35 mm rail Mounting

76 x 56.5 x 117.5
67 x 46
/ 35 mm rail Mounting

76x 56.5 x 117.5


67 x 46
/ 35 mm rail Mounting

Aux
Supply

Less than 2 secs. for OV & 2 - 5 secs for UV

UV
RYB

3 Ph

R B

RBY

OV
Aux
Supply

RYB

Unbal./
Phase Fail

UV
RYB

3 Ph

Td : 2-5 Sec.

R B

RBY

OV

UV

Aux
Supply

RYB

RYB

3 Ph

Unbal./
Phase Fail

R B

Td : 2-5 Sec.

Td : 2-5 Sec.

14

13

14

16

17

13

14

16

17

13

15

13

15 16

18

13

15 16

18

L3

L1

L1
L2

L2

MOTOR

L3

L1

MOTOR

L2

L3

N/V

N/V

OFF

ON

OFF

N/V

ON

DOL STARTER

1 2 3 4 5 6

ALV D2
1 2 3 4 5 6

1 2 3 4 5 6

HLS D2

7 8 9 10 11 12
AUX.
SUPPLY
7 8 9 10 11 12

AUX.
SUPPLY
7 8 9 10 11 12

AUX.
SUPPLY

13 14 1516 17 18

13 14 1516 17 18

13 14 1516 17 18

Relay contact position shown in 'Power on' (Healthy) condition

12

OFF

DOL STARTER

DOL STARTER

HLV D2

RYB

Unbal./
Phase Fail

13

RBY

OV

ON

MOTOR

P H A S E F A I L U R E R E L A Y S
VST D1

P2 PFV1

F3 PFV1

Phase Failure with Under Voltage

Phase Failure with UV / OV Relay

Phase Failure with UV / OV Relay

Phase Failure, Phase Sequence,


under voltage,
Auto Reset, Adjustable trip delay,
Adjustable UV setting,
1 CO output relay
Selectable range of supply voltage

Phase Failure, Unbalance, Phase Sequence,


under voltage, Over Voltage
Auto Reset, Fixed Unbalance setting,
Adjustable UV/OV settings,
2 CO output relay

240 / 415 / 575 V AC 3 Phase (15% selectable)


Built-in
1 CO

Phase Failure, Unbalance, Phase


Sequence,
under voltage, Over Voltage
Auto Reset, Fixed Unbalance setting,
Adjustable UV/OV settings,
1 CO output relay

380 / 415 V AC 15%, 50/60 Hz

Built-in
2 CO

240 / 380 / 415 V AC 20%, 50 / 60 Hz


110 / 240 / 380 / 415 / 440 V AC 20%
1 CO

80% of V set
N.A.

Yes
40 V 6 V (fixed)
85% to 95% (adjustable)
105% to 115% (adjustable)

Yes
40 V 6 V (fixed)
80% - 95% (adjustable)
105% - 120% (adjustable)

0.2 - 10 secs. (variable)


0.2 - 10 secs. (same for UV & SP)
Auto
300 gms.

3.5 secs. 1.5 sec


Less than 2 secs.
Auto
250 gms.

3.5 secs 1.5 sec.


Less than 2 secs.
Auto
430 gms.

75 x 30.5 x 117.5
68 centre to centre / 35 mm rail Mounting

80 x 35 x 95
11 - Pin Plug-in

96 x 96 x 76 (Flush mounting)
92 x 92 (cutout)

Yes
N.A.

RYB

RY

R B Y

Phase fail

3 Ph

RYB
UV

RY

3 Ph

Td :0.2-10 Sec.

OV

R B Y

Unbalance /
Phase fail

UV

Aux
Supply

Td : 2-5 Sec.
Td : 2-5 Sec.

13

13

14

15

11

11

UV
RYB

3 Ph

R B

RBY

RYB

Unbal./
Phase Fail

Td : 2-5 Sec.

NO

NC

L1

L1

L2

L3

L2

L3

MOTOR

MOTOR
MOTOR

N/V

N/V

OFF

ON

OV

OFF

MOTOR

ON

DOL STARTER

DOL STARTER
1

VST D1

5
7

13 14 15

4
3
2

6 7
8

NO

NC

B
D

~
~

AUX.
SUPPLY

9
10

11

Bottom view

Relay contact position shown in 'Power on' (Healthy) condition

13

P H A S E F A I L U R E R E L A Y S
D2 VMR 1

D2 VMR 2

S2 VMR 3

Phase Failure with UV / OV (3-3W)

Phase Failure with UV / OV (3-4W)

Phase Failure with UV / OV Relay

US

Suitable for 3 Ph-3W system,


Microcontroller design,
Absolute values of UV/OV settings,
Phase Failure, Unbalance, Phase
Sequence, under voltage, Over Voltage,
Auto/Manual reset, Adjustable settings
for Unbalance, UV/OV and trip delays,
2 CO output relay

Supply Voltage
System
Auxiliary
Output Contacts
Trip Setting (Volts)
Phase Sequence
Phase Unbalance

US

Suitable for 3 Ph-4W system,


Microcontroller design,
Absolute values of UV/OV settings
Phase Failure, Unbalance, Phase
Sequence, under voltage, Over Voltage
Auto/Manual reset, Adjustable settings for
Unbalance, UV/OV and trip delays,
2 CO output relay

Microcontroller design,
SMD Technology,
Absolute values of UV/OV settings,
Phase Failure, Unbalance, Phase
Sequence, under voltage, Over Voltage
Auto/Manual reset, Adjustable settings
for Unbalance, UV/OV and trip delays,
2 CO output relay

100-120 / 220-240 / 380-440V AC 20%, 48-63 Hz


Built In (from 3 Phases)
2 CO

100-120 / 220-240 / 380-440V AC 20%, 48-63 Hz


Built In (from 3 Phases)
2 CO

100-120 / 220-240 / 380-440V AC 20%, 48-63 Hz


Built In (from 3 Phases)
2 CO

YES
4 % - 20 % [Variable]

YES
4 % - 20 % [Variable]

YES
4 % - 20 % [Variable]

Under
Voltage

For 380-440V AC
For 220-240V AC
For 100-120V AC

285-425V AC [Variable]
165-225V AC [Variable]
75-115V AC [Variable]

165 - 445V AC [Variable]


95 -135V AC [Variable]
45 - 65V AC [Variable]

285-425V AC [Variable]
165-225V AC [Variable]
75-115V AC [Variable]

Over
Voltage

For 380-440V AC
For 220-240V AC
For 100-120V AC

400-520V AC [Variable]
230-290V AC [Variable]
105-140V AC [Variable]

230-310V AC [Variable]
130-170V AC [Variable]
60-80V AC [Variable]

400-520V AC [Variable]
230-290V AC [Variable]
105-145V AC [Variable]

Instant

Instant

Instant

1 To 10 Sec [Variable)
Auto/ Manual Reset (For NC Push Buttons)
300 gms.

1 To 10 Sec [Variable)
Auto/ External Manual Reset (For NC Push Buttons)
300 gms.

1 To 10 Sec [Variable)
Auto/ Manual Reset [Selectable]
110 gms (Approx.)

76 X 56.5 X 117.5
67 x 46
/ 35 mm rail Mounting

76 X 56.5 X 117.5
67 x 46
/ 35 mm rail Mounting

35 X 60 X 90
35 mm Rail Mounting

Trip Time Delay


On Phase Sequence
On SP/UV/OV
Resetting Mode
Weight
Dimensions (mm)
Overall (L x W x D)
Mounting (L x W)

Wherever not specified


Contact Rating :
5A @ 230 V AC
(resistive)
* CE marked products
available on request.

RYB

RY

14

16

17

15

16

18

13

L
O
A
D

Y
B

OV

R B Y

RYB

UV

14

16

17

15

16

18

3 Ph

L
O
A
D

Y
B

R
Y
B

MANUAL
RESET
PB

MANUAL
RESET
PB

Relay position shown in 'Power off' condition

10

11

10

12

OV

R B Y

Td : 1-10 Sec.
Td : 1-10 Sec.

RY
Unbalance /
Phase fail

Td : 1-10 Sec.
Td : 1-10 Sec.

13

RY
Unbalance /
Phase fail

3 Ph N

UV

Td : 1-10 Sec.
Td : 1-10 Sec.

13

RYB

OV

R B Y

Unbalance /
Phase fail

3 Ph

13

14

US

UV

VOLTAGE / CURRENT / FREQUENCY / POWER

MONITORING RELAYS
These relays are best suitable for monitoring balanced or
unbalanced supplies, either of single phase, 3-phase 3wire or 3-phase 4 wire loads powered by generators, UPS,
stabilizers, inverters, or Mains (by Electricity Boards /
Utilities); in AMF panels, PCCs, distribution boards and for
power monitoring of
individual loads / motors /
pumps.

MODELS

FEATURES

PROTECTIONS / FUNCTIONS

VCR D2, D1 VCR1


UVT D1, UVF D1,
VCT D2, VCF D2, D2 VCT1,
S2 VMR 4, S2 VMR 5,
D2 EFR1, CCSD2, OCS D1,
S2 CMR2, S2 CMR3, S2 CMR4,
FCS D2, OFS D1, S2 FMR2,
RPT D2, RPF D2,
PMR D2 + PTS D1,
F3 VSR1, F3 VSR2, F3 VSR3

Fixed/adjustable under/Over trip


settings for parameters.
Fixed/adjustable trip delays and
Power On delays
Built-in or external power supply
Resetting Auto or Manual
Output contacts : 1 CO or 2 CO
Choice of enclosures (DIN-Rail,
Plug-in, Flush)
Models with Micro-Controller
based design
2 line alpha-numeric LCD display
(for F3 VSR1/2)
Serial Communication (RS232)
port (for F3 VSR1/2 models)
Use of SMD Technology
User-friendly LED indications

Under/over Voltage,
Under/Over Current
Under/Over Frequency
Under/Over Power
Reverse Power
Earth Fault/Ground Fault
Earth leakage

Ordering Instructions
Product Family Name
Model Name
System Supply Voltage &
frequency
Aux. Supply/Control supply
voltage
Current input (1A or 5A)

15

VOLTAGE MONITORING RELAYS


VCR D2

D1 VCR 1

VCT D2

1 Phase Voltage Monitoring Relay

Single Phase Under &


Over voltage, Auto /
Manual Reset,
Adjustable under/over
voltage settings,
adjustable trip delay / on
delay,
2 CO output relay

System Supply
Output Relay Contact
Trip Setting
Under Voltage

VCF D2

Voltage Monitoring
Relay, 3-3W

Single Phase Under &


Over voltage, Auto /
Manual Reset,
Adjustable under /
over voltage settings,
adjustable trip delay,
2 CO output relay.

3-Phase 3-Wire Under


& Over voltage
Auto/Manual Reset,
Adjustable under/over
voltage settings,
adjustable trip delay &
ON delay,
2 CO output relay

Voltage Monitoring
Relay, 3-3W

3-Phase 4-Wire Under


& Over voltage
Auto/Manual Reset,
Adjustable under/over
voltage settings,
adjustable trip delay &
ON delay,
2 CO output relay

3-Phase 3-Wire Under


& Over voltage
Auto/Manual Reset,
Adjustable under/over
voltage settings,
adjustable trip delay &
ON delay,
2 CO output relay

110/240/380/415/440 V AC +20%, 25% 50/60Hz


2 CO
2 CO

110 / 240 V AC (+20%, -25%) 50/60Hz


2 CO

220-240 (+ 20% - 30%), 50/60 Hz


2 CO

75% - 95% (adjustable)

75 - 95% [Variable] of set value

105% - 120% (adjustable)

105 - 120% [Variable] of set value 105% -120% (adjustable)

Trip Time Delay


Power on Delay
Reset
Weight
Dimensions (mm)
Overall (L x W x D)
Mounting

1 - 10 secs. (adjustable)
1 - 10 secs. (adjustable)
Auto / Manual
450 gms.

2- 5 Sec (Fixed) (UV/OV)

Auto Reset
180 gms.

76 x 56.5 x 117.5
67 x 46
/ 35 mm rail
mounting

76 x 30.5 x 117.5
68 centre to centre / 35 mm rail
mounting

Wherever not specified


Contact Rating :
5A @ 230 V AC
(resistive)

240/380/415 V AC 15% 50/60Hz

2 CO

75% - 95% (adjustable)

85% - 95% (adjustable)

105% -120% (adjustable)

105% - 115% (adjustable)

1-10 secs. (adjustable)


1-10 secs. (adjustable)
Auto / Manual
450 gms.

1-10 secs. (adjustable)


1-10 secs. (adjustable)
Auto / Manual
450 gms.

1-10 secs. (adjustable)


1-10 secs. (adjustable)
Auto / Manual
200 gms.

76 x 56.5 x 117.5
67 x 46
/ 35 mm rail
mounting

76 x 56.5 x 117.5
67 x 46
/ 35 mm rail
mounting

75 x 35 x 95
11 - Pin plug in

75% - 95% (adjustable)

Over Voltage

P2 SMV1

Voltage Monitoring
Relay, 3-4W

OV SET
OV RESET

3 Ph

OV SET

OV SET

OV RESET

OV RESET

OV SET

1 Ph N

1 Ph N

OV RESET

3 Ph

UV RESET
UV RESET

UV RESET

UV SET

13

14

16

17

13

15

16

18

TD
1 to 10sec.

TD 2 to 5sec.

TD

T on

1 to 10sec.

UV SET

UV SET

13

14

13

15

TD
1 to 10sec.

TD

13

14

15

13

16

16

17

T on

L
O
A
D

OFF

L
O
A
D

Y
B
N

L
O
A
D

Y
B

ON

ON

ON

N/V

D1 VCR1
1

N/V

1 2 3 4 5 6
VCT D2

VCR D2

A/M
LINK

A/M
LINK

1 2 3 4 5 6

N/V

VCF D2
A/M
LINK

7 8 9 10 11 12

5
4
3
2

6 7
8
9
10

11

7 8 9 10 11 12
7

13

14

15

Bottom view
13 14 151617 18
13 14 151617 18

13 14 151617 18

Relay contact position shown in 'Power on' (Healthy) condition


16

11

OFF

1 2 3 4 5 6

7 8 9 10 11 12

TD

T on

1 to 10sec.

L
O
A
D

OFF

ON

OFF

L
N

N/V

11

18

TD

TD
1 to 10sec.

1 to 10sec.

UV RESET

UV SET

EXT.
PUSH
BUTTON

VOLTAGE MONITORING RELAYS


UVT D1

UVF D1

Under Voltage
Relay 3-3W

D2 VCT1

Under Voltage
Relay 3-4W

S2 VMR4

Voltage Monitoring
Relay

3-Phase 3-Wire Under


voltage
Auto Reset, Adjustable
under voltage settings,
adjustable trip delay,
1 CO output relay

3-Phase 4-Wire Under


voltage
Auto Reset, Adjustable under
voltage settings, adjustable
trip delay,
1 CO output relay

N.A.

US

US

3-Phase 3-Wire Under & Over


voltage, Microcontroller based
design, SMD Technology
Auto/Manual Reset, , Adjustable
under/over voltage settings,
Absolute values for UV/OV,
adjustable trip delay & ON delay,
2 CO output relay (or selectable
1CO for UV, 1CO for OV)
Failsafe-non-failsafe selectable

3-Phase 4-Wire Under & Over


voltage, Microcontroller based
design, SMD Technology, Auto /
Manual Reset, Adjustable
under/over voltage settings,
Absolute values for UV/OV,
adjustable trip delay & ON delay,
2 CO output relay (or selectable
1CO for UV, 1CO for OV)
Failsafe-non-failsafe selectable

100-120 / 220-240 / 380-440V AC 20%, 50/60 Hz


1 CO + 1 CO / 2 CO

100-120 / 220-240 / 380-440V AC 20%, 48-63 Hz


1 CO + 1 CO / 2 CO

100-120 / 220-240 / 380-440V AC 20%, 48-63 Hz


1 CO + 1 CO / 2 CO

285-425V AC (Variable)
165-225V AC (Variable)
75-115V AC (Variable)

285 - 425V AC (Variable)


165-225V AC (Variable)
75-115V AC (Variable)

165-245V AC (Variable)
95-135V AC (Variable)
45-65V AC (Variable)

Ph Ph Sensing:
For 380-440V AC
For 220-240V AC
For 100-120V AC
Ph N Sensing:
For 380-440V AC
For 220-240V AC
For 100-120V AC

N.A.

US

Ph Ph Setting:
For 380-440V AC
For 220-240V AC
For 100-120V AC
Ph N Sensing:
For 380-440V AC
For 220-240V AC
For 100-120V AC

75% - 95% (adjustable)

Voltage Monitoring
Relay, 3-4W

3-Phase 3-Wire and 3-Phase


4-Wire (selectable) Under & Over
voltage, Microcontroller based
design, Auto/Manual Reset,
Adjustable under/over voltage
settings, Absolute values for
UV/OV, adjustable trip delay &
ON delay, 2 CO output relay (or
selectable 1CO for UV, 1CO for OV)
Failsafe-non-failsafe selectable

110 / 240 / 380 / 415/440 V AC+20 / -25%, 50 / 60 Hz


1 CO
1 CO
75% - 95% (adjustable)

S2 VMR5

Voltage Monitoring
Relay, 3-3W

45-65V AC (Variable)
90-130V AC (Variable)
165-245V AC (Variable)
400-520V AC (Variable)
230-290V AC (Variable)
105-145V AC (Variable)

400-520V AC (Variable)
230-290V AC (Variable)
105-145V AC (Variable)
230-310V AC (Variable)
130-170V AC (Variable)
60-80V AC (Variable)

60-80V AC (Variable)
130-170V AC (Variable)
230-310V AC (Variable)

1 - 10 secs. (adjustable)
3.5 secs. 1.5 secs.
Auto
175 gms.

1- 10 secs. (adjustable)
3.5 secs 1.5 secs
Auto
175 gms.

1-10 Sec (Variable) SP/UV/OV


1-10 Sec (Variable)
Auto/ Manual Reset
300 gms (Approx.)

1-10 Sec. (Variable)


1 10 Sec (Variable)
Auto / Manual Reset

1-10 Sec. (Variable)


1 10 Sec (Variable)
Auto / Manual Reset

110 gms (Approx.)

110 gms (Approx.)

76 x 30.5 x 117.5
68 centre to centre / 35 mm rail
mounting

76 x 30.5 x 117.5
68 centre to centre / 35 mm rail
mounting

76 X 56.5 X 117.5
67 x 46 mm / 35 mm rail mounting

35 X 60 X 90
35 mm Rail Mounting

35 X 60 X 90
35 mm Rail Mounting

3 Ph N

UV RESET
OV SET

UV SET

OV RESET

OV RESET

TD
1 to 10sec.

14

13

14

16

17

13

15

16

18

TD
1 to 10sec.

UV SET

TD
1 to 10sec.

TD

T on

1 to 10sec.

UV RESET

UV RESET

UV RESET

2 to 5 sec.

3 Ph N

3 Ph

UV SET

TON

13

OV RESET

OV SET

OV SET

3 Ph N

10

11

10

12

T on

1 to 10sec.

UV SET

TD
1 to 10sec.

TD

10

11

10

12

TD

T on

1 to 10sec.

15

13

L
O
A
D

R
Y
B
OFF

L
O
A
D

Y
B
N
OFF

L
O
A
D
N

R
Y
B

R
Y
B
N

ON
N/V

ON
N/V

OFF

UVT D1

UVF D1

A/M
LINK

A/M

13

14

LINK

13

14

15

15

Relay position shown in


'Power on' (Healthy) condition

Relay position shown in 'Power off' condition


17

CURRENT MONITORING RELAYS


CCS D2

OCS D1

S2 CMR2

1 Phase Current Monitoring Relay

1 Phase Over Current Relay

1 Phase Current Monitoring Relay

Single phase under & over current


Auto/Manual reset,
Input 1A or 5 A through CT,
Adjustable under/over current trip
settings,
Adjustable trip delay & ON delay,
2 CO output relay
Supply Voltage
System
Auxiliary
Ext. Input
Output contact

Single phase under & over current


Microcontroller based design, SMD
technology, Auto/Manual reset, Input 1A
or 5 A through CT, Adjustable under / over
current trip settings, adjustable trip delay
& ON delay, 2 CO output relay (or
selectable 1CO for UC, 1CO for OC)
Failsafe-non-failsafe mode selectable

Single phase over current


Auto reset,
Input 1A or 5 A through CT,
Adjustable over current trip
settings,
Adjustable trip delay,
1 CO output relay

110 / 240 / 380 /415V AC 20%, 12 V DC / 24 / 30 V DC 10%

1 Amp or 5 Amp (Selectable) CT


2 CO

US

110 / 240 V AC 20%, 24 V DC 10%

1 Amp or 5 Amp (Secondary) CT


1 CO

1 Amp or 5 Amp (Secondary) CT


1 CO + 1 CO

Trip setting

EF Trip Setting
Under Current

10%-100% (adjustable)

Over Current
Power On Delay
Trip Time Delay
Resetting
Weight
Dimensions (mm)
Overall (L x W x D)
Mounting (L x W)

N.A.

50% - 140% (Variable)

50% -140% (adjustable) of CT sec

50% -140% (adjustable) of CT sec

1 - 10 secs (adjustable)
1 - 10 secs (adjustable)
Manual / Auto
550 gms.

3.5 secs 1.5 sec (fixed)


1 - 10 secs (adjustable)
Auto
250 gms.

10% - 100% (Variable)


1-10 Sec. (Adjustable) 1 Sec.
1-10 Sec. (Adjustable) 1 Sec.
Auto / Manual
140 gms

76 x 56.5 x 117.5
67 x 46
/ 35 mm rail Mounting

76 x 30.5 x 117.5
68 centre to centre / 35 mm rail Mounting

35 X 60 X 90
35 mm Rail Mounting

Wherever not specified


Contact Rating :
5A @ 230 V AC
(resistive)

Aux. Supply

Aux. Supply

Aux. Supply

OC SetPoint

OC SetPoint

OC Reset

OC Reset

OC SetPoint

UC Reset

UC SetPoint

OC Reset
UC Reset

UC SetPoint

Current Input

Current Input

T ON
1 to 10 sec.
13

14 16

17

13

15 16

18

Current Input

AUTO
RESET

T ON
2 to 5 sec.

Td
1 to 10 sec.

L
O
A
D

L
N

13

14

13

15

1 2

7 8 9 10 11 12

13 14 15 16 17 18

11

9 10

12

DOL STARTER
ON OFF

AUX.
SUPPLY
7

13 14 15

Relay contact position shown in 'Power on' (Healthy) condition

18

10

OCS D1

ON OFF
LINK

N/V

DOL STARTER

CCS D2

AUX.
SUPPLY

AUTO
RESET

Td 1 to 10 sec.

L
O
A
D

L
N

N/V
1 2 3 4 5 6

T ON
1 to 10 sec.

Td 1 to 10 sec.

Relay position in
'Power off' condition

GROUND FAULT MONITORING RELAYS


D2 EFR1

S2 CMR3

S2 CMR4

Earth Fault Relay

Ground Fault Relay

Earth Leakage Relay

Earth fault/Ground fault monitoring of


3 phase systems
Manual Reset,
Input 1A or 5A through CBCT,
Adjustable earth fault trip setting,
adjustable trip delay,
2 CO relay output

110 / 240 / 380 / 415 V AC 20%

US

Earth fault/Ground fault monitoring of


3 phase systems, Microcontroller based
design, SMD technology, Manual Reset,
Input 1A or 5A through CBCT,
Adjustable earth fault trip setting,
Adjustable trip delay & ON delay,
2 CO relay output
Failsafe-non-failsafe seletable

US

Earth leakage monitoring of 3 phase


systems, Microcontroller based design,
SMD technology, Manual Reset,
Input through CBCT,
Adjustable trip setting,
Adjustable trip delay & ON delay,
2 CO relay output
Failsafe-non-failsafe seletable

100-110/240/380/415V AC 20%, 48-63 Hz


100-110/240V AC / 24V DC 20%

100-110/240/380/415/440V AC 20%, 48-63 Hz


100-110/240V AC / 24V DC 20%

2 CO

2 CO

10% -100% (adjustable) of CT sec

10% - 100% of Rated Current Input (Variable)


(Input through CT of 1AMP or 5AMP Secondary)

10% - 100% of Rated Current Input (Variable)


(Input through CBCT of 300m A Secondary)

N.A.

N.A.

N.A.

N.A.
N.A.
0.1-1.0 / 1-10 Sec. (Adjustable)
Manual / Remote (Selectable)
550gms.

N.A.

N.A.

1 -10 Sec.(Adjustable)
0.1 - 1 Sec.(Adjustable)
Manual
140 gms

1 -10 Sec.(Adjustable)
0.1 Sec to 1 Sec.(Adjustable)
Manual
140 gms

76 x 56.5 x 117.5
67 x 46
/ 35 mm rail Mounting

35 X 60 X 90
35 mm Rail Mounting

35 X 60 X 90
35 mm Rail Mounting

1A or 5A (Selectable) CBCT
1 CO (2 CO) (Pick up on Fault)

Td
13

14

16

17

13

15

16

18

EXTERNAL
5 Amp. CT.

Td

CBCT(ZCT)

CBCT ( ZCT)

R
Y
B

MOTOR

N/V

R
Y
B

M
OFF

OFF ON

ON

N/V

1 2 3 4 5 6

AUX.
SUPPLY

AUX.

SUPPLY

D2 EFR1

13 14 15 16 17 18

*Use either
3 x 5A Ext. CTs
or 3 x 1A Ext. CTs
or 1 x 5A (or 1A) CBCT

Relay position in
'Power on' (Healthy) condition

S2 CMR 4

7 8 9 10 11 12

Relay position shown in 'Power off' condition

19

FREQUENCY MONITORING RELAYS


FCS D2

OFS D1

S2 FMR1

Frequency Monitoring Relay

Over Frequency Relay

Frequency Monitoring Relay

Single phase under & over frequency


Auto reset,
Adjustable under/over frequency trip
settings,
Adjustable trip delay & ON delay,
2 CO output relay

Supply Voltage
System
Auxiliary
Ext. Input
Output contact
Trip setting
Under Current
Over Current
Under Frequency
Over Frequency
Under Power
Over Power
Reverse Power
Power On Delay
Trip Time Delay
Resetting
Weight
Dimensions (mm)
Overall (L x W x D)
Mounting (L x W)

Wherever not specified


Contact Rating :
5A @ 230 V AC
(resistive)

US

Single phase under & over frequency,


Microcontroller based design, SMD
technology, Auto reset,
Adjustable under/over frequency trip
settings,
Adjustable trip delay & ON delay,
2 CO output relay
Failsafe-non-failsafe mode selectable

Single phase over frequency


Auto reset,
Adjustable over frequency trip
settings,'
Adjustable trip delay,
1 CO output relay

110 / 240 / 380 / 415 V AC 20%


Built-in

2 CO

110 / 240 / 380 / 415 V AC 20%


12 / 24 V DC or Built in
1 CO

100-110/240V AC 20%, 38-72 Hz


In Built or 24V DC 20%

1 CO + 1 CO

40 Hz - 60 Hz (variable)
50 Hz - 70 Hz (variable)

1 - 10 secs. (adjustable)
1 - 10 secs. (adjustable)
Auto
450 gms.

N.A.
50 Hz - 70 Hz

3.5 secs. 1.5 sec (fixed)


1 - 10 secs. (adjustable)
Auto
450 gms.

40 Hz - 60 Hz (Variable)
50 Hz - 70 Hz (Variable)

1 - 10 Sec.(Adjustable) 1 Sec.
1 - 10 Sec.(Adjustable) 0.1 Sec.
Auto / Manual
130 gms

76 x 56.5 x 117.5
67 x 46
/ 35 mm Rail Mounting

76 x 30.5 x 117.5
68 centre to centre / 35 mm Rail Mounting

35 X 60 X 90
35 mm Rail Mounting

Aux. Supply
Aux. Supply

OF SetPoint

OF SetPoint

Aux. Supply

OF Reset

OF Reset

OF SetPoint

UF Reset

UF SetPoint

Freq. Input
Freq. Input

T ON
1 to 10 sec.
13

14 16

17

13

15 16

18

T ON
2 to 5 sec.

Td
1 to 10 sec.

13

14

13

15

Td 1 to 10 sec.

T ON
1 to 10 sec.
7

8 10

11

9 10

12

AUTO
RESET

Td
1 to 10 sec.

L
O
A
D

L
O
A
D

UF Reset

Freq. Input

AUTO
RESET

OF Reset

UF SetPoint

OFF

ON

N/V
DOL STARTER

N/V
1 2 3 4 5 6

DOL STARTER

FCS D2

ON

OFF

OFS D1

LINK

SYSTEM / AUX.
SUPPLY

7 8 9 10 11 12

13

14

15

13 14 1516 17 18

Relay contact position shown in 'Power on' (Healthy) condition


20

Relay position in 'Power off' condition

POWER MONITORING RELAYS


RPT D2

RPF D2

PMR D2 + PTS D1

Reverse Power Relay,(3-3W)

Reverse Power Relay,(3-4W)

Motor Power Monitoring Relay

3-phase 3-wire generators reverse


power monitoring
Auto/Manual reset,
Reverse power (current) trip settings
adjustable,
ON delay and trip delay adjustable,
2 CO output relay

Single phase or 3-phase 4-wire


generators reverse power monitoring
Auto/Manual reset,
Reverse power (current) trip settings
adjustable,
ON delay and trip delay adjustable,
2 CO output relay

Under Power & Over Power Monitoring


Auto/Manual Reset,
Adjustable UP/OP settings,
Adjustable On delay and trip delay,
2 CO output relays

3 Ph/3 W, 110/240/380/415 V AC 20%


Built-in
5A, CT & R,Y, B
2 CO

3 Ph/4 W, 110/240/380/415 V AC 20%


Built-in
5A, CT & R,Y, B
2 CO

3 Ph/3 W, 110/240/380/415 V AC 20%


Built-in
PTS D1 (1A/5A CT & 3Ph)
1 CO + 1 CO

2% - 20% (adjustable)
1 - 10 secs. (adjustable)
1 - 10 secs. (adjustable.)
Auto / Manual
460 gms.

2% - 20% (adjustable)
1 - 10 secs. (adjustable)
1 - 10 secs. (adjustable)
Auto / Manual
460 gms.

10% - 100% (adjustable)


10% - 100% (adjustable)

1 - 10 secs. (adjustable)
1 - 10 secs. (adjustable)
Auto / Manual
400 gms.

76 x 56.5 x 117.5
67 x 46
/ 35 mm Rail Mounting

76 x 56.5 x 117.5 x 27
67 x 46
/ 35 mm Rail Mounting

76 x 56.5 x 117.5
67 x 46
/ 35 mm Rail Mounting

Supply

On
Off
Td

3 Ph
Supply

13

% over
Power Setting

3 Ph N
Supply

Forward Power

Increasing Foward Current

Forward Power

Increasing Foward Current

Reverse Power

Increasing Reverse Current

Reverse Power

Increasing Reverse Current

Recovery
Level

Recovery
Level

Current Tripping
Level

Current Tripping
Level

14 16

17

13

14 16

15 16

18

T ON

Td

Zero Power
during power on

17

Over
16
Power Relay

Td 1 to 10 sec.

13

1 to 10 sec.

15 16

18

Start
Up Delay

Start
Up Delay

Under
Power Relay 13

Td 1 to 10 sec.

13

% under
Power Setting

T ON

1 to 10 sec.

14

On
Off
On
Off

17
Current Zero

R
Y
B

P1

P2

S1

S2

L
O
A
D

External
5 Amp Secondary CT

R
Y
B

MOTOR
P1

P2

S1

S2

1 2 3 4 5 6

ON

OFF

NV
1

RPT D2

PTS D1

7 8 9 10 11 12

RPF D2

9
R1

13 14 15

DOL STARTER

PMR D2

A/M
LINK

13 14 15 16 17 18

10 11 12
R2

13 14 15 16 17 18

Connection Cable

Relay contact position shown in 'Power on' (Healthy) condition

21

VOLTAGE SCANNERS & CONTROLLERS


F3 VSR1

F3 VSR2

F3 VSR3

Voltage Scanner 3-3W

Voltage Scanner 3-4W

Voltage Scanner & Phase Selector

3-Phase 3-Wire voltage monitoring &


display, Phase Failure, Unbalance, Phase
Sequence, under voltage, Over Voltage,
Auto / Manual Reset,
Adjustable unbalance trip setting,
Adjustable under/over voltage settings,
adjustable trip delay,
RS232 communication port,
2 CO output relay
Supply voltage
System
Auxiliary
Output relay contacts
Trip setting
Phase Sequence
Phase Unbalance
Under Voltage
Over Voltage
Trip time delay
Reset
Display
Monitoring
Weight
Dimensions (mm)
Overall (L x W x D)
Mounting (L x W)

Wherever not specified


Contact Rating :
5A @ 230 V AC
(resistive)

3-Phase 4-Wire voltage monitoring &


display, Phase Failure, Unbalance,
Phase Sequence, under voltage, Over
Voltage, Auto / Manual Reset,
Adjustable unbalance trip setting,
Adjustable under/over voltage settings,
Adjustable trip delay,
RS232 communication port,
2 CO output relay

3-phase 4-wire system voltage


monitor with phase selector
Under voltage and over voltage
monitoring Auto reset,
Adjustable UV/OV trip settings,
Adjustable trip delay,
5x1No output relays.

380 / 415 V AC (3 Ph - 3 W)
90-270 V AC/DC
2 CO & RS 232 (optional)

380 / 415 V AC (3 Ph - 4 W)
Self Powered (Neutral & any Phase)
2 CO & RS 232 (optional)

415 VAC,+ 20 % -30 %, 50 Hz / (60Hz) 3 %


48 VDC 10 %
5 Nos. x 1NO.

Yes
1 - 10 % (Adj.)
1 - 80V below nominal voltage
1 - 60V above nominal voltage
1 - 60 secs. or 1-5 mins select.
Manual
Backlit LCD (16 x 2 character)
Phase to Phase
800 gms.

Yes
1 - 10 % (Adj.)
1 - 50V below nominal voltage
1 - 25V above nominal voltage
1 - 60 secs. or 1-5 mins select.
Manual
Backlit LCD (16 x 2 character)
Phase to neutral
800 gms.

No

75 % TO 95 % [VARIABLE BY POT]
105 % TO 120 % [VARIABLE BY POT]
1-10 SEC. [VARIABLE BY POT]
AUTO

96 x 96 x 130
92 x 92

96 x 96 x 130
92 x 92

96 x 96 x 130
92 x 92

RP, UV / OV and UB Protection override facility provided

RP, UV / OV and UB Protection override facility provided

On Delay - 3mins 10%

RESET

RESET

RESET

SP

RESET

UB>SET

RESET

RESET

RESET

RP

Phase to neutral
900 gms.

RESET

SP

RESET

UB>SET

RESET

AUX.
SUPPLY

RP

RO

RYB

OV SET

LINE

RYB

OV SET
YO

LINE

OV

UV

UV
UB/SP

UB/SP

UV SET

UV SET

SP

SP

UB/SP

LED

LED

RELAY
C-NO

RELAY
C-NO

OV

UV
UB/SP

UV

UB/SP

UB/SP

BO
HVAC

T2
YO

T2
RO
T1

T2
RO

BO

SMPS

RO

T1

T1

T1

YO

BO

T1

T1

ALARM
T 1 - ON DELAY FOR HVAC AND SMPS.
T2 - TRIP DELAY.

AUX.
SUPPLY

C2 NO2 NC2

C2 NO2 NC2

RS232

B
Y
R

RS232

C1 NO1 NC1

C1 NO1 NC1
AUX.
SUPPLY
48V DC

R
Y
B

22

R
Y
B
N

Relay contact position shown in 'Power on' (Healthy) condition

+ -

C1

C3 NO3 C4

NO1 C2 NO2

NO4 C5 NO5

MOTOR / PUMP PROTECTION RELAYS


These relays are useful for
protection of 3-phase AC induction
motors against various hazards.
With their unique advantages they
eliminate use of a thermal/bimetal
relay for motor protection. Being
current sensing, they are to be
selected according to motor rating
and are available for practically all
ranges of motors. These relays
are ideally suitable for Airconditioning Compressor motor
protection, as also for motors in
machines, conveyors,
cranes/hoists and lifts, and for
pumps.
MODELS

FEATURES

PROTECTIONS / FUNCTIONS

MPR D2, SPG D2, F3 DRC1,


D2 MPR1, D2MPR2, S2 CMR1
CTS5, CTS10, CTS20, CTS40,
CTS80, CTS120, S2 CTS,
MBMPR, M-Commander,
WTR D1, S2 WTR1,

Fixed/adjustable unbalance
settings
Fixed/adjustable settings for
under/over voltage, current, load
Fixed/adjustable trip delays
Resetting Auto or Manual
Output contacts : 1 CO or 2 CO
Choice of enclosures (DIN-Rail,
Flush)
Models with Micro-Controller
based design
Serial Communication (RS485)
port
2 line alpha-numeric LCD display
Use of SMD Technology
User-friendly LED indications

Phase Failure (Phase


Loss/Single Phasing),
Phase sequence reversal,
Voltage Unbalance,
Under Voltage,
Over Voltage,
Overload protection as per
motor characteristics
No-load/dry running
Motor Winding overheating
Over-current/Short
circuit/locked rotor
Earth Fault
Moisture/leakage

Ordering Instructions

Product Family Name


Model Name
System Supply Voltage & frequency
Aux. Supply/Control supply voltage
Motor/Pump rating (HP/KW) & duty
Overload characteristics required
No. of PTCs & Temp. graph

23

MOTOR / PUMP PROTECTION RELAYS

Supply Voltage
System
Auxiliary
Output Relay Contact
Input

MPR D2

SPG D2

F3 DRC1

Overload Protection Relay


with Phase Failure

Dry Run & Overload Protection


Relay with Phase Failure

Dry Run & Overload Protection


Relay with Phase Failure

Phase Failure, Unbalance, Phase


sequence and overloading
Auto / Manual Reset,
Adjustable current trip settings,
selectable characteristics,
1CO/2CO output relay

Phase Failure, Unbalance, Phase


sequence, Overloading & Dry running
Auto/Manual Reset,
Adjustable current trip settings,
selectable overload characteristics,
1CO/2CO output relay

Phase Failure, Unbalance, Phase


sequence, overloading and dry
running
Auto/Manual Reset,
Adjustable current trip settings,
Adjustable overload characteristics,
1CO output relay

380/415/440V AC 20%
110/240/380/415 V AC/24 V AC 20%, 50 / 60 Hz
1 CO (2 CO)

240/380/415 V AC 20%
1 CO

240/380/415 V AC 20% 50/60 Hz 3%


110 / 240 / 380/ 415 V AC 20% 50 / 60 Hz
1 CO

From CTS

From CTS

From CTS

Phase to phase unbalance

50% of motor Current 10%

Under current (Dry running)

N.A.
Above 120% of set Current (IDMTL)

50% of motor Current


50%/75% of set current
Above 120% of set current (IDMTL)

50% of I FLC
50% or 75% of I SET
Above 120% of set current (IDMTL)

N.A.

N.A.

N.A.

5.5 secs. 1.5 secs.

5.5 secs. 1.5 secs.


As per selectable inverse time Characteristics
2 / 5 secs (10 secs.)

5.5 secs. 1.5 secs.

As per selectable inverse time Characteristics


(2 secs. / 5 secs.) or 10 secs. or 15 secs. or 20 secs. (optional)

110/240/380/415/440 V AC / 24 V AC 20%, 50/60 Hz

Trip Setting

Overload
UV/OV
Trip type delay
On phase failure
For overloading
UV/OV RP
Resetting
Dimensions (mm)
Overall (L x W x D)
Panel mounting (L x W)
Approx Weight

As per selectable inverse time Characteristics


2 - 10 secs. (variable)

N.A.

N.A.

N.A.

Auto / Manual / Remote

Auto / Manual / Remote

Auto / Manual / Remote

67 x 46

76 x 56.5 x 117.5
/ 35 mm Rail Mounting

76 x 56.5 x 117.5
67 x 46
/ 35 mm Rail Mounting

96 x 96 x 76
92 x 92

425 gms.

425 gms.

425 gms.

Motor
Current
(%)

Wherever not specified


Contact Rating :
5A @ 230 V AC (resistive)

O/L

700 %
600 %
400 %
200 %

Motor
Current
(%)

120 %
100 %
10 %
0%

RYB

As per IDMTL

T1

RYB

/ / /

3 ph

T1

T2

14

13

15

As per IDMTL

T1

13

14

13

15

T1 = O/L Trip Delay


T2 = SP Trip Delay

T1

O/L

700 %
600 %
400 %
200 %
120 %
100 %

Phase Fail

10 %
0%

T2
4 to 7 sec.

13

Motor
Current
(%)

120 %
100 %

Phase Fail

/ / /

3 ph

O/L

700 %
600 %
400 %
200 %

10 %
0%

Phase Fail

RYB

/ / /

3 ph

T2
T1

T2
4 to 7 sec.

NO

NC

T1 = O/L Trip Delay


T2 = SP / DR Trip Delay

As per IDMTL

T1

T2
4 to 7 sec.

T1 = O/L Trip Delay


T2 = SP / DR Trip Delay

5Amp. Sec. CT

R
Y
B

MOTOR

5 Amp. Sec. CT

R
Y
B

R
Y
B

ON OFF

N/V

N/V

Dol Starter

Dol Starter

ON

Aux
Supply

LINK
11 12

RI

BI

13 14 15 16 17 18

RO

BO

9 10

LINK

4 5

SPG D2

CTS- 5

AUX.
SUPPLY

A
B
C
E
F
G
H

1 2 3

CTS
5/10

LINK

7 8 9 10 11 12

RI

BI

RO

BO

LINK

13 14 15 16 17 18

Submersible
Pump

Link at 17, 18 for


2 or 5 secs. IDMTL curve

24

OFF

F3 DRC1

LINK

C
1 2 3

MPR-D2

ON

OFF

Relay contact position shown in 'Power on' (Healthy) condition

C
NO
NC
EXT.
P.B. D
A/M
LINK
DRY D
RUN
LINK

AUX.
SUPPLY

Submersible
Pump

MOTOR / PUMP PROTECTION RELAYS


CTS5
CTS10

CTS20,
CTS40,
CTS80

Current sensor
suitable for motor
current of 5A (for
CTS 5) & of 10A
(for CTS 10)
& for Higher
ratings with
external CT. To be
used with Minilec
relays only.

Current sensor
suitable for full
load motor
current of 20A
(for CTS 20), of
40A (for CTS 40)
& 80 A (for CTS
80) To be used
with Minilec
relays only.

S2 CMR1

D2 MPR2

D2 MPR1

Dry Run & Overload Protection Dry Run & Overload Protection Dry Run & Overload Protection
Relay with Phase Failure
with Phase Failure & UV+OV
Relay with Phase Failure
R

US

US

US

Phase Failure, Unbalance, Phase


sequence and overloading,
Auto/Manual Reset,
Adjustable current trip settings,
Test Facility,
UC bypass facility,
selectable overload characteristics,
2CO output relay

Sensing both voltage and


current signals, Phase Failure,
Unbalance, Phase sequence,
under over voltage,
overloading and dry running.
Manual Reset, Delayed auto
reset, fixed trip settings, fixed
overload characteristics,
2CO output relay

Phase Failure, Unbalance, Phase


sequence, overloading and dry
running (Under current)
Microcontroller based design,
SMD technology,
Auto/Manual Reset,
Adjustable current trip settings,
selectable overload
characteristics,
2CO output relay

415 / 440V AC 20%, 45-65 Hz


220-240 / 380-440V AC
2 CO

380-440V AC 20%, 48-63 Hz


220-240 20%
2 CO

100-120/220-240/380-440V AC 20%, 48-63 Hz


100-120/220-240 20%, 24V DC +10% - 15%
2 CO

50% of Motor Current (Fixed)


50% to 80% of set current (Adj.with Bypass facility)
As per inverse time characteristics

50% of Motor Current (Fixed)


50% of set current (Fixed)
As per inverse time characteristics
UV = -20% (Fixed) OV = +20% (Fixed)
4 Sec 1%

50% of Motor Current (Fixed)


40% to 80% of set current
As per inverse time characteristics
N.A.
4 Sec 1 Sec (Fixed)

N.A.
N.A.
N.A.
N.A.
N.A.

N.A.
N.A.
N.A.
N.A.
N.A.

As per Inverse Time Characteristics


2 Sec. (Fixed)
For UV/OV - 4 Sec 1 Sec for RP - Instant

As per Inverse Time Characteristics


2/5/10 Sec. (Selectable)

N.A.

N.A.

N.A.
Auto / Manual

N.A.

N.A.

Delayed Auto

56.5 x 117.5 x 76
/35 mm Rail Mounting

56.5 x 117.5 x 76
/35 mm Rail Mounting

89 x 17.5 x 59
35 mm Rail Mounting

76 x 30.5 x 117.5
68 centre to centre/

76 x 38 x 113
68 centre to centre/

400 gms

400 gms

140 gms

240 gms.

N.A.
4 Sec 1 Sec
As per Inverse Time Characteristics
2/5/10 Sec. (Selectable)
N.A.
Auto/ Manual (Remote with NC Push Button)

O/L

Motor 700 %
Current 600 %
400 %
(%)
200 %
120 %
100 %
10 %
0%

RYB

/ / /

3 ph

T2
T1

13

14

16

17

13

15

16

18

120 %
100 %

Phase Fail

As per IDMTL

10 %
0%

RYB

/ / /

3 ph

T2
T1

T2

13

14

16

17

13

15

16

18

T1 = O/L Trip Delay


T2 = SP / DR Trip Delay

As per IDMTL

O/L

Motor 700 %
Current 600 %
400 %
(%)
200 %
120 %
100 %

Phase Fail

T1

N.A.
N.A.
3-wire Output

Motor Primary current carrying cables for R&B phases

O/L

Motor 700 %
Current 600 %
400 %
(%)
200 %

N.A.
N.A.
3-wire Output

10 %
0%

Phase Fail

RYB

/ / /

3 ph

T1

T2
T1

T2

10

11

10

12

T1 = O/L Trip Delay


T2 = SP / DR Trip Delay

As per IDMTL

T1
T2

T1 = O/L Trip Delay


T2 = SP / DR Trip Delay

CTS 20 : 260 gms.


CTS 40 : 275 gms.
CTS 80 : 330 gms.

Selection Chart for CTS.


HP
KW
Amp
<3
<2.25
2-5
<6
<4.5
4 - 10
<12.5
<9.4
8 - 20
<30
<22.5
16 - 40
<60
<45
32 - 80
<75
<56
48 - 120

CTS Model
CTS 05
CTS 10
CTS 20
CTS 40
CTS 80
CTS 120

100

10

MINUTES

R
Y
B

R
Y
B

10 SEC.
8 SEC.

ABCD

REMOTE
RESET
NC P.B.

ABCD

6 SEC.

4 SEC.

50

CTS

2 SEC.

40

CTS
SECONDS

AUX.
SUPPLY

AUX.
SUPPLY

TIME

UNIT

UNIT

REMOTE
RESET
NC P.B.

30
20
10
8
6
4
2
0

0.10.2 0.3 0.40.50.60.70.8 0.9 1 1.11.21.31.41.5

Relay position shown in 'Power off' condition

TIMES FULL LOAD CURRENT

25

MICROPROCESSOR BASED MOTOR PROTECTION RELAY


MBMPR

S2 CTS1

Comprehensive Motor Protection Relay

Current Sensor

US

Microcontroller based.
Sensing voltage, current and temperature
Phase Failure, Unbalance, Phase
sequence, Under/over voltage,
overloading, winding over temperature,
Over current/Short circuit, locked rotor
Auto/Manual resetting,
Adjustable trip settings for UV/OV, UC/OC,
O/L, Locked rotor & earth fault,
On delay & start-up delay adjustable,
2x1CO output relays
Current sensor suitable for
full load motor current of
5A. 10A & 20A. To be used
with Minilec relays only.
Supply Voltage
System
Auxiliary
Output Relay Contact
Input
Power Consumption
Trip Setting
Settings

Under Current
(dry run)

for
CDR-M

Over Current/
Short Circuit
Overload
Lock Rotor
Earth Fault
Winding Overheat

Trip Level

1% - 20%
75% - 95%

105% - 120%
20-60% of Imax

30-90% of Imax
300% - 800%
of Imax
2/5/10/15/20 Sec.
200%-500% of Imax
30% - 80%
4K1 - 5K6
16x2 Ch. ( Back lit )

Display
Dimensions (mm)
Unit Overall (L x W x D)
Panel mounting (L x W)
Approx Weight Unit

Trip Delay

1-10 Secs.
1-10 Secs.
1-10 Secs.
1-10 Secs.
1-10 Secs.
1-10 Secs.

LED

2-25 Secs.

Multi Attempt
Manual
Manual
Manual
Auto / Manual

1-10 Secs.
0.5 - 10 Secs.

1-20 Secs.

M1
M2

M3

B
OFF

R
G

CON6

CON1
T4 T3 T2 T1

RELAY OUTPUT

26

CON3
NC2 NO2 C2 NC1 NO1 C1

TRIP

S2

CT INPUT

ALARM

SYSTEM SUPPLY

CON2

AUX. SUPPLY

Y
B

RS-232 OUTPUT

S1

Reset Mode

Auto / Manual
Auto / Manual
Auto / Manual
Multi Attempt
Multi Attempt
Multi Attempt

As per IDMTL char.

PTC-1 FOR ALARM

PTC-2 FOR TRIP

(L x W x D)

35 X 60 X 90

Mounting 35 mm Rail Mounting

CT MODULE ( CT20 / CT50 )

Overall

166 x 216 x 80 CT20/CT50 : 35 x 60 x 90


: 35mm Rail Mounting
153 x 203
600 gms
CT20/CT50 : 150gms

EXTERNAL CBCT OF
5Amp OUTPUT

N
L
CON4

Dimensions (mm)

8 VA

Power ON
Unbal/Ph.Rev
Under Voltage
Over Voltage
Current unbalance
Current phase Loss

Wherever not specified


Contact Rating :
5A @ 230 V AC (resistive)

3-wire Output
Input from Motor Primary current
carrying cables for R&B phases

415V AC 20%, 3, 3 Wire, 50 / (60)Hz 3%


90-270V AC / DC
1 CO for Trip & 1 CO for Alarm / RS 232/485 Port
External CTS ( CT20/50 )

ON

M1

Approx Weight 140 gms.

CTS Selection Chart


Model
S2 CTS 5
S2 CTS 10
S2 CTS 20

Current
2-5
4-10
8-20

MICROPROCESSOR BASED PUMP AUTOMATION SYSTEM


M-COMMANDER

CTS120

Pump Management & Protection System

Current Sensor

Commander-M is a micro-processor based


Motor protection and Pump management
system, suitable for 2 pumps.
Sensing voltage, current and temperature
Phase Failure, Unbalance, Phase sequence,
Under/over voltage, overloading, dry
running, winding over temperature, Over
current/Short circuit, locked rotor
Auto/Manual resetting,
Adjustable trip settings for UV/OV, UC/OC,
O/L, Locked rotor & earth fault,
On delay & start-up delay adjustable,
2x1CO output relays

Current sensor suitable


for full load motor current
of 120A. To be used with
Minilec relays only.

PARAMETERS
Supply Voltage
System
Auxiliary
Output Contacts
Current sensor
Reset
Unbalance

Motor protection Includes


Over/Under voltage protection
Single/Reverse phasing protection
Voltage / Current unbalance
Overload trip
Over current protection
Dry running protection
Earth fault protection
PTC based winding overheating protection
Pump Management System Features
Auto Change over between two pumps
Intelligent resetting facility
On-site programming facility
Password protection for programming
Pump On-Off timer programmable for 10
times a day, with advance programming of
7 days
Provision for water level control
Run-time compensation
Ideal for Pump Automation & Unmanned
Pumping Stations.

SPECIFICATIONS
415 V AC 20%, 50/60Hz 3%
90-270 VAC/DC 20%, 50Hz
4 x 1 CO Relays (for 1 pump)
External CTS ( CT20 / CT50)
Auto/ Multi-Attempt / Manual
1-20% 6V for Voltage Unbalance
20-60% 5% of current unbalance
As per inverse time characteristics
300% - 800%

Overload
Over Current /
Short Circuit
Locked Rotor
Earth Fault
Winding Overheating
Under Voltage
Over Voltage
Dry Running

200% - 500%
30% - 80%
As per PTC temperature characteristics
75% - 95% of system supply (adjustable)
105%-120% of system supply (adjustable)
30-90% of Imax

Display

16x2 Ch. ( Backlit )

Level Control

Upper tank full

Weight

800gms

Lower tank empty

3-wire Output
Input from Motor Primary current
carrying cables for R&B phases
Dimensions (mm)
Overall (L x W x D) 76 x 78 x 96.5
Mounting (L x W) 62 x 51
Approx Weight 190 gms. each

R
Y
B

MOTOR
M

N/V

DOL STARTER

SPG D2
SSG D2
MPR D2 1 2 3
F3 DRC1 A B C

ON

SPG D2 14
SSG D2
MPR D2 13

CTS 120
(R Phase)

CTS 120
(B Phase)

Wherever not specified Contact Rating : 5A @ 230 V AC (resistive)

For more detailed specifications, refer table on page No. 26 (MBMPR)

EXTERNAL CBCT OF
5Amp OUTPUT

CT MODULE (CT20 / CT50)

M1

M2

Y
B

OFF

CT INPUT
INPUT

RELAY OUTPUT

PUMP-1

NC4 NO4 C4 NC3 NO3 C3 NC2 NO2 C2 NC1 NO1 C1

PUMP-2

PUMP-1 PRIMING

PUMP-2

M2

M2

ON

CON1

CON3
PUMP-2 PRIMING

M1

M3
OFF

C IP1 P4 P5 P6 P1 P2 P3

CON2

S2

CON6

T4 T3 T2 T1

Y
B

SYSTEM SUPPLY

AUX. SUPPLY

E
N
L
CON4

M1

ON

N
S1

PUMP-1

M3

P6
P5

WINDING TEMP SENSOR


( PTC - 1) FOR PUMP- 1

P4
UPPER TANK

WINDING TEMP SENSOR


( PTC - 2) FOR PUMP- 2

OFF

NO
F3 DRC1
C

P3
P2
P1
LOWER TANK

27

WINDING OVER-TEMPERATURE PROTECTION RELAYS

Supply Voltage
Auxiliary
Output Contacts
Trip Setting
Thermistor Sensor Healthy

Thermistor Sensor Trip


Thermistor Sensor Open
Thermistor Sensor Short

Trip time delay


Resetting Mode
Dimensions (mm)
Overall (L x W x D)
Mounting (L x W)
Weight

WTR D1

S2 WTR1

PTC

Winding Protection Relay

PTC Thermistor Relay

Thermistor

Sensing motor winding


temperature through PTC
Thermistors,
Winding overheating, sensor
short, sensor open faults
Suitable for single,
triple or 6/9/12 PTCs

Sensing motor winding temperature


through PTC Thermistors,
Winding overheating, sensor short,
sensor open faults
Suitable for single,
triple or 6/9/12 PTCs

24 / 48 / 110 / 240 / 380 / 415 / 440V AC / 24 V DC 10%


1 CO

12/24V DC / 110/230/415V AC, 50 Hz (60 Hz)


1 CO

40 ohm - 4 K ohm
4.1 K ohm - 5.5 K ohm
5.6 K ohm & above
40 ohm & below
Less than 2 secs.

40 4K
4.1K 5.5K
5.6K & Above
0 - 39
Less than 1 Sec (Fixed)

Auto / Manual (optional)

Auto / Manual ( Optional )

76 x 30.5 x 117.5
68 mm centre to centre / 35 mm Rail Mounting
300 gms.

90 x 60 x 35
35 mm Rail Mounting
250 gms.

PTC Thermistors are semi conductor sensors.


These have typical characteristics that change their
resistance instantly at a specified pre-defined
response temperature (NRT). As soon as the
surrounding temperature of PTC reaches it's NRT
value the body resistance of PTC Thermistor rises
sharply from 200 / 250 Ohms to more than 5000
Ohms.The PTC Thermistors are embedded in the
overhang location of the motor windings.
The NRT value of PTC is selected according to the
Insulation Class of the copper windings of motor or
transformers.

Selection Chart for NRT of PTC Thermistors.


TYPICAL CHARACTERISTICS OF PTC (THERMISTOR)

Wherever not specified


Contact Rating :
5A @ 230 V AC (resistive)

RESISTANCE IN OHMS

RESISTANCE VS TEMPERATURE

PTC
O/P
THERMISTOR
CONDITION RELAY
AND TRIP STATUS
SETTINGS

NRT

Class

Cable Colour

of Ins.

Code

70

White - Brown

80

White - White

90

Green - Green

100

Red - Red

110

Brown - Brown

120

Grey - Grey

130

Blue - Blue

140

White - Blue

150

Black - Black

160

Blue - Red

170

White - Green

180

White - Red

190

Orange - Black

OPENED
(RESISTANCE
> 5.6k)

6000
5600

UNHEALTHY
(RESISTANCE
>4.2k < 5.5k)

5000
4000

Relay Reset
Zone
(>1.5K<1.8K)

3000

2000
1500
1000
500

HEALTHY
RESISTANCE
>39W<4K

250
200

100
250C
ROOM TEMP.

NRT-20

NRT-5 NRT NRT+5 NRT+15

SHORTED
(RESISTANCE
< 3.9W

M1

M2

M3

N/V

OFF

MOTOR

M1

M2

M3

ON

DOL STARTER
Aux.
Supply
1

5 6

S2 WTR1

WTRD1
Aux.
Supply
7

13

14

15

Reset
Reset

28

ELECTRONIC TIMERS
Minilec offers timers for various fuctions and applications,
in various enclosures/sizes and with multi voltage options

MODELS

FEATURES

FUNCTIONS

ETS D1, ETA D1,


P1 STS1, P1 STM1,
ESD D1, ESR D1,
D1 ETM1, S2ETM1
ETR D2, D2 ETR1,
S2 ETM2

Single voltage & Multi-voltage


Single function and multi-function
Wide time range
Better repeat Accuracy
Choice of enclosures (DIN-Rail, &
Plug-in)
Models with Micro-Controller
based design
Use of SMD Technology (S2 Series
models)

On Delay
Interval Delay
Cyclic ON/OFF
Multi-Attempt (for Engine Starting)
Star-Delta changeover

Ordering Instructions
Product Family Name
Model Name
Aux. Supply/Control supply
voltage
Application
29

ON DELAY TIMERS
ETS D1

ETA D1

P1 STS1

On Delay Timer

On Delay Timer (Multivoltage)

On Delay Timer (Seconds)

On Delay, time range upto 3


hours,
2 CO output relay

Supply Voltage
Auxiliary

On Delay, time range 30


Minutes, Multi-voltage supply,
2 CO output relay

On Delay, time range upto 60


seconds,
1 CO output relay

24/110 / 240 / 380 / 415 V AC 20%,


12 / 24 V DC 20%

24-240 V AC / DC
+10%, 20%

110 / 230 / 380 / V 415 V AC 10%,


12/24 V DC

Output Contacts

2 CO

2 CO

1 CO

Time Range

0.3 - 3, 0.6 - 6 secs.


1 - 10, 3 - 30, 6 - 60, 18 - 180 (secs. or mins.)

0.7 secs. - 30 mins.

0-3, 0-10, 0-30, 0-60 secs.

Operating Modes

On Delay

(4 ranges)
On Delay

On Delay

Weight
Dimensions (mm)
Overall (L x W x D)

300 gms.

160 gms.

175 gms.

76 x 30.5 x 120
68 mm centre to centre / 35 mm Rail Mounting

76 x 30.5 x 117.5

50 x 40 x 80

68 centre to centre / 35 mm Rail Mounting

8 - pin plug-in

Mounting (L x W)

Aux.
Supply
Wherever not specified
Contact Rating :
5A @ 230 V AC (resistive)

13

14

13

15

Aux.
Supply
T Set

13

14

13

15

Aux.
Supply
T Set

T Set

3
4

AUX.
SUPPLY

AUX.
SUPPLY
7

13 14 15
L
N

30

Bottom
view

13 14 15

Starter/CB
Coil

7
1

L
N

Starter/CB
Coil

Relay contact position shown in 'Time Elapsed condition

3
8

DC
AC
AUX. SUPPLY

SPECIAL FUNCTION TIMERS


P1 STM1

ESD D1

ESR D1

D1 ETM1

S2 ETM1

On Delay Timer (Minutes)

Star Delta Timer

Multi Attempt Timer

Multi Function Timer

Multi Function Timer

On Delay, time range


upto 60 minutes,
1 CO output relay

US

Microcontroller based,
SMD technology
Multi-function timer (On
delay, interval delay,
cyclic, star-delta, Engine
starting), time range upto
100 Hrs,
2x1CO output relays

Generator Engine
starting relay, Upto 15
attempts, start time &
pause time selectable,
2x1co output relays

Microcontroller based
Multi-function timer (On
delay, interval delay,
cyclic, star-delta,
Engine starting), time
range upto 100 Hrs,
2x1CO output relays

110 / 230 / 380 / V 415 V AC 10%,


12/24 V DC

110 / 240 / 380 / 415 V AC 20%


+10% to 20%

110/240 V AC 20%, 50/60 Hz


12 / 24 V DC 20%

*24/110/240/415VAC, 20%,
12/24 VDC

*24/110/240/415VAC, 20%,
12/24 VDC

1 CO

1 NO-Star relay (NO)


1 NO-Delta relay (NO)

1 CO + 1 CO

1 CO + 1 CO

1 CO + 1 CO

0-3, 0-10, 0-30, 0-60 mins

0.7 60 secs.
in 2 diff. ranges

Start Time - 1 - 15 secs


Pause Time - 2 - 16 secs.

0.1-1,1- 10, 6 - 60, 60-600 seconds


0.1- 1, 1-10,10-100 hours

0.1-1,1- 10, 6 - 60, 60-600 seconds


0.1- 1, 1-10,10-100 hours

On Delay

Star Delta Changeover Time


50 / 100 m.secs.

Start Attempts - 1 - 15 nos.

M1
M2
M3
M4
M5
M6
M7

M1
M2
M3
M4
M5
M6
M7

175 gms.

175 gms.

175 gms.

200 gms (Approx.)

50 x 40 x 80

76 x 30.5 x 117.5

8 - pin plug-in

68 centre to centre

76 x 30.5 x 117.5
68 centre to centre

76 x 30.5 x 117.5
35 x 90 x 60
68 mm centre to centre / 35 mm Rail Mounting 35 mm Rail Mounting
*CE/CSA Not available for 110VAC models *CE/CSA Not available for 110VAC models

Aux.
Supply

T Set

13

14
13

- ON Delay
- Interval (Selectable By Rotary Switch)
- Cyclic Instant
- Cyclic Delayed
- Star Delta *
- Instant & Delayed
- Engine Start Mode

150 gms (Approx.)

50/100 msec
1

START
RELAY
14
ON

1 2 3

ALARM
RELAY
ON

Tp

Ts

1 2 n

PRESET
NUMBER
OF STARTS

Aux.
Supply

7
1

Bottom
view

3
8

- ON Delay
- Interval (Selectable By Rotary Switch)
- Cyclic Instant
- Cyclic Delayed
- Star Delta *
- Instant & Delayed
- Engine Start Mode

AUX.
SUPPLY

Y- Transfer Time
8

Star to Delta
Changeover timer,
Time range upto 60
seconds,
2x1NO output relays

Aux.
Supply
8

US

1
R1

R2

L
O
A
D

Start
Failure
Alarm

OFF

ON

N/V

Aux

AUX.
SUPPLY

Supply

DC
AC
AUX. SUPPLY

9
1

13 14 15

13 14 15
Starter/
Solenoid/
Load

Relay contact position shown in 'Time Elapsed condition

D1 ETM1
7

13

14

15

Relay position shown in 'Power off' condition

31

CYCLIC TIMERS
S2 ETM2

D2 ETR1

ETR D2

Cyclic Timer

Cyclic & Forward-Reverse Timer

Cyclic & Forward-Reverse Timer

Unequal cyclic function,


on time and pause time
selectable,
2x1CO output relays

Supply Voltage
Auxiliary

US

Unequal cyclic and forwardreverse functions, on time and


pause time selectable,
2x1CO output relays

US

Microcontroller based, SMD


technology
Unequal cyclic and forwardreverse functions,
on time and pause time
selectable,
2x1CO output relays

*24/110/240/415VAC, 20%,
12/24 VDC

24 V DC

*24/110/240/415VAC, 20%,
12/24 VDC

Output Contacts

1 CO + 1 CO

1 CO + 1 CO

1 CO + 1 CO

Time Range

0.7 secs. 30 mins.


in 4 diff. ranges
Forward / Reverse Cycle
with pause time

On Time 0. 1 Sec.To 100 Hrs.


Pause Time- 0. 1 Sec.To 100 Hrs
Mode 1 Unequal Cyclic Operation
Mode 2 Forward Reverse Cyclic Operation

On Time0. 1 Sec.To 100 Hrs.


Pause Time- 0. 1 Sec.To 100 Hrs
Mode 1 Unequal Cyclic Operation
Mode 2 Forward Reverse Cyclic Operation

410 gms.

200 gms (Approx.)

100 gms (Approx.)

76 x 56.5 x 117.5
/ 35 mm Rail Mounting

67 x 46

76 x 56.5 x 117.5
/ 35 mm Rail Mounting

35 x 90 x 60
35 mm Rail Mounting

*CE/CSA mark not available for 110VAC models

*CE/CSA mark not available for 110VAC models

110/240/415 V AC 20%

Operating Modes
Weight
Dimensions (mm)
Overall (L x W x D)
Mounting (L x W)

Wherever not specified


Contact Rating :
5A @ 230 V AC (resistive)

67 x 46

Aux.
Supply
T2
13

T2

14

16

17

13

15

16

18

13

14

13

15

16

17

16

18

T1

14

T1
16

13

T2

17

T1 - On Time
T2 - Pause Time

1 2 3 4 5 6

Aux.
Supply

L
O
A
D

ETR D2
AUX
SUPPLY

OFF

ON

Aux.
Supply

N/V

7 8 9 10 11 12

LINK

1 2 3 4 5 6

13 14 15 16 17 18

D2 ETR 1

L1

9 10 11 12

L2
13 14 15 16 17 18

N
L1: Load1
L2: Load2

32

Relay position in 'Power on' (Healthy) condition

Relay position shown in 'Power off' condition

LIQUID LEVEL CONTROLLERS


These are suitable for conductive liquids like water and for
non-conductive liquids like Diesel/Oil. Models for either
one level monitoring or two level monitoring.

MODELS

FEATURES

FUNCTIONS

WLC D1, Electrodes,


P1 LCW1, P2 LCW1,
S2 WLC1, P2 ALT1
DLC D1 + FRKP 1,
FRKP4

Can be used for potable water,


water with impurities and for
diesel/oil
Cable size & length no
restriction for water level
monitoring
Suitable for variety of electrodes
Optical sensing for diesel/oil
level monitoring
Open collector output (for
FRKP4)
Choice of enclosures (DIN-Rail,
& Plug-in,)
Models with Micro-Controller
based design
Use of SMD Technology (S2
Series models)

Level monitoring of conductive


and non-conductive liquids
One level or two level
monitoring
One tank or two tank level
monitoring

Ordering Instructions

Product Family Name


Model Name
System Supply Voltage
Aux. Supply/Control supply
voltage
Type of liquid & its specifications
33

LEVEL CONTROLLERS - CONDUCTIVE LIQUIDS


WLC D1

P1 LCW1

Water Level Control Relay Two Level Single Tank

Water Level Control Relay Two Level Single Tank

Single tank - 2 level control


relay, suitable for conductive
liquids, sensitivity adjustment,
1CO output relay

Auxiliary Supply
Output Contacts
Input Sensors
Sensitivity
Trip Time Delay
Weight
Unit
Sensor (each)
Dimensions (mm)
Unit
Overall (L x W x D)
Mounting (L x W)
Sensor
Overall

Single tank - 2 level control


relay, suitable for conductive
liquids,
1CO output relay

24 /110 / 240 / 380 / 415 V AC 10%, 50 / 60 Hz, 12 / 24 V DC


1 CO
3 Electrodes
1KW - 200 KW (adjustable)
Less than 1 sec

24 /110 / 240 / 380 / 415 V AC 10%, 50 / 60 Hz, 12 / 24 V DC


1 CO
3 Electrodes
N.A.
Less than 1 sec

300 gms.
50 gms.

125 gms
50 gms

76 x 30.5 x 117.5
68 centre to centre

50 x 40 x 80
8 - pin plug-in

24 (Dia) x 76 (L)

24 (Dia) x 76 (L)

Aux Supply

Aux Supply
p2
p1

Suction (Source)
Tank Water Level

p3

p2
p1

p3

p2
p1

p3

p2
p1

p3

p2
p1

p3

Suction (Source)
Tank Water Level

13

14

13

15

p2
p1

p3

p3

p2
p1

p3

p2
p1

M1

R
Y
B

M2

MOTOR

M3

Link
N/V

E2

WLC D1
AUX.
SUPPLY

7 8 9

E3

7
1

ON

P2

DC
AC
AUX. SUPPLY
E3 E2

13 14 15

P3

Bottom
view
1 2 3

E1

OFF

DOL STARTER

34

p2
p1

P1

Relay position in 'Power on' (Healthy) condition

E1

p3

p2
p1

p3

P2 LCW1

S2 WLC1

P2 ALT1

Water Level Control Relay Two Level Two Tanks

Two tanks - 2 level control


relay, suitable for conductive
liquids,
1CO output relay

Alternating Relay

Single tank 2 level control relay,


operates on 24 V AC supply,
sensitivity adjustment, suitable for
conductive liquids,
1CO output relay,

24 /110 / 240 / 380 / 415 V AC 10%, 50 / 60 Hz, 12 / 24 V DC


1 CO
6 Electrodes
N.A.
Less than 1 sec

24 V AC / DC
1 CO
3 Electrodes
0W To 220 KW (Continuous)
Less than 1 sec (Fixed)

215 gms
50 gms

200 gms.
50 gms.

75 x 35 x 95
11- pin plug-in

90 x 35 x 60
35 MM Rail Mounting

24 (Dia) x 76 (L)

24 (Dia) x 76 (L)

This is a simple 'Step Relay' to achieve alternating


duty of two pumps or compressors. Operation of
two pumps or compressors is achieved in
alternating sequence as per either pressure switch
or level control or thermostat contact. Product is
available in 11 pin (P2) plug-in enclosure.

Aux Supply
Frequency
Power Consumption
Output Relay Contact

110/220/230/240/380/415 V AC
24 V DC 15 %
50 Hz / 60 Hz 3%
5 VA max.
2 NO

Indication
ON
RLY
Operations

Power ON (Green)
Relay ON (Red)
30 Operation/Min. (max.)

Dimensions (H x W x D)
Mounting
Weight

85 x 35 x 90mm
11 pin plug in base mounting
250 gms. (approx.)

Aux Supply
p5
p4

p6

p5
p4

p6

p5
p4

p6

p5
p4

p6
p4

p5

p6

Aux Supply

Overhead Tank
p2
p1

p3

p2
p1

p3

p2
p1

p3

p2
p1

p3

p2
p1

p3

Suction Tank

p2
p1

Suction (Source)
Tank Water Level

p3

p2
p1

p3

p2
p1

p3

p2
p1

p3

p2
p1

p3

PS 2
LEVEL
PS 1
LEVEL
CONTACTOR
PUMP A
CONTACTOR
PUMP B

Wherever not specified Contact Rating : 5A @ 230 V AC (resistive)

5
4
3
2

Bottom
view

9
10

TANK 2

11

P3
P2
DC
AC
AUX. SUPPLY

M1

M2

M3

NC (A) NC (B)

P6
P5
P4

6 7
8

P1
TANK 1

5
4
3
2

Aux.
Supply
1

3 4 5 6

PS1

PUMP 'B'
CONTACTOR

6 7
8
9
10

11

PUMP 'A'
CONTACTOR

S2 WLC1

P3

P2
P1

SUCTION TANK

PS2
AUX. SUPPLY

Relay position in 'Power on' (Healthy) condition

Relay position shown in 'Power off' condition

35

LEVEL CONTROLLERS - NONCONDUCTIVE LIQUIDS


DLC D1 + FRKP 1

FRKP 4

Diesel Level Control Relay Single Level

Diesel Level Sensor Switch Single Level

One level switch for diesel/oil,


optical sensing principle,
1 CO output relay

Auxiliary Supply
Output Contacts
Input Sensors
Sensitivity
Trip Time Delay
Weight
Unit
Sensor (each)
Dimensions (mm)
Unit
Overall (L x W x D)
Mounting (L x W)
Sensor
Overall

Either high level or low level


switch (selectable),
open collector output

110 / 230 / 415 V AC /12 V / 24 V DC / AC


1 CO
1 (FRK P1)
N. A.
Less than 5 sec

12 V / 24 V DC
Open Collector 400 mA @ 24 V DC
Built-in sensor
N. A.
Less than 1 sec

300 gms.
100 gms.

100 gms

76 x 30.5 x 117.5
68 centre to centre

18 (Dia) x 75 (L)

18 (Dia) x 75 (L)

Aux Supply
Suction
Diseel Fuel Level

Aux Supply

Aux Supply

Diseel Fuel Level

Diseel Fuel Level


Load ON

Load ON

13

14

13

15

Load OFF

Load OFF
NPN-MakeSwitching

NPN- Make Switching

M1

R
Y
B

M2

PNP - Break Switching

RED

MOTOR

M3

ON
N/V

OFF

ON

DOL STARTER

200mA
MAX.
GREEN

10 VDC
TO
28 VDC

BLACK
-

1 2 3

DLC D1

PNP- Break Switching

AUX.
SUPPLY
3 CORE
CABLE

7 8 9

13 14 15
LIQUID TANK
SENSOR PROD

36

Relay position in 'Power on' (Healthy) condition

RED

GREEN
200mA
MAX.
BLACK

10 VDC
TO
28 VDC

POWER LINE TRANSDUCERS


Power line transucers are suitable for measuring electrical
parameters like AC voltage, current, frequency, PF, KW,
KVAR and also for DC signal isolation. They are best suited
for MCC and PCC panels, AMF panels, SCADA systems, PLCs
for data acquisition and metering.

MODELS

FEATURES

FUNCTIONS

D2 PTV1, D2 PTC1,
D3 PTF1, D5 PTA1,
D5 PTW1, D5 PTW2,
D3 IST1, D5 IST1

Fully solidstate electronic


design.
Rugged to withstand harsh
environments
Load independent outputs
Galvanically isolated signals
Accuracy class : 0.5%
(Optional 0.2%)
Self or auxiliary powered.
CT burden : less than 0.5 VA

Convert high value AC signal to


low value DC signals
Inputs voltage, current,
frequency, power factor, power
Outputs DC signals single or
dual (optionally 3 or 4 for
Isolation transducers)

Ordering Instructions

Product Family Name


Model Name
System Supply Voltage
Aux. Supply/Control supply
voltage
37

VOLTAGE, CURRENT, FREQUENCY TRANSDUCERS


D2 PTV1

D2 PTC1

D3 PTF1

AC Voltage Transducer

AC Current Transducer

Line Frequency Transducer

Voltage transducer, Input AC


voltage, Output (DC) single or
dual, accuracy 0.5%

Auxiliary Supply
Power Consumption
Input Value I in
V in
DC Output (Single / Dual)
No of Signal Output
Response Time
Input / Output isolation
Temperature
Humidity
Dimensions (L x W x D) (mm)
Weight

Current transducer, Input AC


Current, Output (DC) single or
dual, accuracy 0.5%

Frequency transducer, Output


(DC) single or dual, accuracy
0.5%

Self Powered, 110/240 V AC 20%


24 / 48 / 110 / 220 V DC 20%
3.5 VA - AC, 4 VA - DC
3.5 VA - AC, 4 VA - DC
3.5 VA - AC, 4 VA - DC
Freq. Range 45 to 55 Hz /40 - 60 Hz/55 - 65 Hz / 48 - 52 Hz
N.A.
0 -1 A AC / 0 - 5 A AC
110 / 240 / 415 V
N.A.
110 / 415 V
0 - 1 mA, 0 - 5 mA, 0 - 10 mA, 0 - 20 mA, 4 - 20 mA, 0 - 5 V, 0 - 10 V Other optional on request
Single (Optional Dual Output)
Single (Optional Dual Output)
Single (Optional Dual Output)
Less than 500 miliseconds
Galvanic
Galvanic
Galvanic
00C to + 550 C
00C to + 550 C
00C to + 550C
Up to 95% Rh non condensing
Up to 95% Rh non condensing
Up to 95% Rh non condensing
75 x 56.5 x 117.5
75 x 56.5 x 117.5
75 x 83.5 x 117.5
440 gms
440 gms
575 gms
110 / 240 V AC, 20% 24 / 48 / 110 / 220 V DC 20%

INPUT
CURRENT

INPUT
VOLTAGE

NOMINAL INPUT
VOLTAGE

1 2 3 4 5 6

1 2 3 4 5 6

7 8 9 10 11 12

7 8 9 10 11 12

13 14 15 16 17 18

13 14 15 16 17 18

1 2 3 4 5 6 7 8 9

10 11 12 13 14 15 16 17 18
19 20 21 22 23 24 25 26 27

AUX.
SUPPLY

AUX.
SUPPLY

38

DC OUTPUT

AUX.
SUPPLY

DC OUTPUT

DC OUTPUT

POWER TRANSDUCERS
D5 PTA1

D5 PTW1

D5 PTW2

Power Factor Transducer

Active Power Transducer

Reactive Power Transducer

Power Factor Transducer, Input


3-phase voltage & current,
output Single or Dual (DC),
Accuracy 0.5%

Reactive Power Transducer, Input


3-phase voltage & current, output
Single or Dual (DC), Accuracy 0.5%

Active Power Transducer, Input


3-phase voltage & current,
output Single or Dual (DC),
Accuracy 0.5%

Self Powered, 110/240 V AC, 24 / 48 / 110 / 220 V DC 20 %


3.5 VA - AC, 4 VA - DC
1A/5A
110 / 415 V

3.5 VA - AC, 4 VA - DC
1A/5A
110 / 415 V
0 - 1 mA, 0 - 5 mA, 0 - 10 mA, 0 - 20 mA, 4 - 20 mA, 0 - 5 V, 0 - 10 V
Single (Optional Dual Output)

Single (Optional Dual Output)


Galvanic
00 C to + 550C
Up to 95% Rh non condensing
73 x 150 x 113
1200 gms.

Galvanic
00 C to + 550 C
Up to 95% Rh non condensing
73 x 150 x 113
1200 gms.

R
U
P
P
L
Y

For 3 Phase 4 Wire Network

1 2 3 4
R
U
P
P
L
Y

S1
P1

5 6
S2
P2 S1
P1

7 8 9 10 11 12 13 14 15 16
S2
P2

RL
YO
B DA
N

R
Y
B
N

P1
S1

P2
S2

1 2 3 4

P1
S1

P2
S2

5 6

3.5 VA - AC, 4 VA - DC
1A/5A
110 / 415 V
Single (Optional Dual Output)
Less than 500 miliseconds
Galvanic
00 C to + 55 0 C
Up to 95% Rh non condensing
73 x 150 x 113
1200 gms.

L
O
A
D

AUX.
SUPPLY

7 8 9 10 11 12 13 14 15 16

AUX.
SUPPLY

DC OUTPUT 1
+

17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
DC OUTPUT
+

39

ISOLATION TRANSDUCERS
D3 IST1

D5 IST1

DC Signal Isolation Transducer

DC Signal Isolation Transducer

Signal Isolation transducer, Input


& output DC signals, Single or
dual outputs, accuracy 0.5%

Auxiliary Supply
Power Consumption
Input Value I in
V in
DC Output (Single / Dual)
No of Signal Output
Response Time
Input / Output isolation
Temperature
Humidity
Dimensions (L x W x D) (mm)
Weight

Signal Isolation transducer,


Input & output DC signals, upto
4 outputs, accuracy 0.5%

Self Powered, 110/240 V AC, 24 / 48 / 110 / 220 V DC 20 %


3.5 VA - AC, 4 VA - DC

3.5 VA - AC, 4 VA - DC
0-1, 0-5, 0-10, 0-20, 4-20mADC Signals
0-50, 0-60, 0-75, 0-100 mADC / 0-1, 0-5, 0-10, 0-150, 0-300, 0-600 V DC
0 - 1 mA, 0 - 5 mA, 0 - 10 mA, 0 - 20 mA, 4 - 20 mA, 0 - 5 V, 0 - 10 V
Single (Optional Dual Output)
Single (Optional Dual or 3 or 4)
Galvanic
00 C to + 55 0C
Up to 95% Rh non condensing
73 x 83.5 x 117.5
1200 gms.

Galvanic
00 C to + 55 0 C
Up to 95% Rh non condensing
73 x 150 x 113
1200 gms.

mA or mV ot V
DC Signal Input
+

DC Signal Up
+

1 2 3 4 5 6 7 8 9

1 2 3 4

AUX.
SUPPLY

5 6

7 8 9 10 11 12 13 14 15 16

17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

10 11 12 13 14 15 16 17 18
19 20 21 22 23 24 25 26 27

AUX.
SUPPLY

40

DC
O/P
2

DC
O/P
1

+
+
DC
DC
OUTPUT4 OUTPUT3

+
+
DC
DC
OUTPUT2 OUTPUT1

AUTOMATION PRODUCTS
Minilec offers variety of controllers for plant/process
automation and data logging PLCs with dedicated softwares,
Flexible SCADA systems ( with hardware ) and with
communication features, these are easliy adoptable to
varying customer needs.

MODELS :

FEATURES

FUNCTIONS

BPC CARD, PPLC,


SCADA Systems MINISCADA,

Digital / Analogue inputs


Digital outputs
RS232 / RS485 Serial
communication link
MODBUS ASCII / RTU protocol
PC side software

Continuous monitoring of
input parameters
Control of process
through outputs &
software
Data acquisition &
communication
Data Storage & records
through PC

Ordering Instructions

Product Family Name


Model Name
Aux. Supply / Control Supply Voltage
Input & output details
Process / application details

41

PROCESS / PLANT CONTROL & AUTOMATION


PRE-PROGRAMMED LOGIC CONTROLLER - PPLC

LOGICON SERIES single chip microprocessor custom built dedicated programs


as per logic sequence user panel flush
mounting facility, 8 way/16 way digital inputs
& outputs, built in timers, open collector /
relay output key board and display and
battery back up.

Some examples
Auxillary supply

90 - 270 V AC / DC

Input signal ( Digital )


( Analogue )

12 Numbers
4 Numbers (0 to 5 VDC, Non Isolated) or
2 Nos. (4-20 mA) + 2 Nos ( 0-5V )

Output signal ( Digital )

12 Numbers ( NO Contacts)
5 AMP@ 230 VAC (Resistive)

Operating temperature

0-600C

Dimensions
Overall (L x W x D)

166 x 216 x 147mm

Mounting (L x W)

153 x 203mm

Weight

1200gms

216mm

Features

203mm

User defined custom - Built operating logic


Keyboard - 4 Keys - Menu, Up, Down, Enter
4 Keys - Function Keys
Display - LCD display 16x2 char backlit
Serial communication [RS - 232C]
Password protection for programming
Inbuilt buzzer with alarm indication
Programmable LED indication

F5 PLC2
R/o Plant Controller
8 Digital Inputs
6 Digital Outputs
2 Keys & 13 stage
Mimic diagram

166mm

153mm

147mm

F5 CHL 1
Chiller Plant Controller
7 Digital Inputs
1 Analog Inputs
4 Digital Outputs
6 Keys & LCD Display

F5 CMP 1
Compressor Plant Controller
8 Digital Inputs
5 Digital Outputs
6 Keys & LCD Display

F5 BLR 1
Boiler Plant Controller
11 Digital Inputs
2 Analog Inputs
6 Digital Outputs
8 Keys & LCD Display

42

PROCESS / PLANT CONTROL & AUTOMATION


BOOSTER PUMP CONTROLLER - BPC

Technical Specifications :

Sequencing of Booster Pumps according to the


pressure switch, duty cycle is a necessity in a
Booster Pump Control System. Minilec Booster
Pump Controller Card fulfils all the
requirements of a Booster Pump Control Panel.
Suitable for 2 / 3 Pumps or 4 /5 Pumps.

Input :
2, 3, 4,5 Pressure Switches, Over load relay
contacts, Water Level Electrodes & Auto /
Manual switches
Outputs :
2 Relay outputs for 2 Pump System OR 3
relay outputs for 3 pump System and
respectively for 4 & 5 pump systems.
Common Alarm Relay output for Buzzer.
Open Collector output :
For LED indications for RUN / Trip on the
panel door For LED indications for LL, HL, O
/ L on the panel door
Operating Sequence:
The key of the Booster Pumps is the
Pressure Switches, which are preset
according to the different pressure levels in
the Pressure Tank. The water pressure in the
Pressure Tank is to be maintained so that the
consumers get constant pressure
irrespective of the variations in the demand.
As the user demand increases the
respective Pressure switches activate &
Booster Pumps are switched ON
sequentially.

_ 10 %, 50 / 60 Hz +
_ 3%
Auxiliary Supply Voltage : 20 V AC +
Inputs
2 Pump
3 Pumps
System
System
Pressure Switch Contacts
2
3
(Potential Free)
Trip Contacts (Potential Free)
2
3
Water Level Inputs (4 Electrodes) HLL, LL & RST HLL, LL & RST
Auto / Manual Selection
2
3
Switches (Potential Free)
Push Buttons for Alarm Mute
1
1
(Potential Free)
Relay Output
1) Pump
2
3
2) Alarm
1
1
Open Collector Output
Water Level Control (HL, LL)
2
2
Pump ON
2
3
Pump Trip
2
3
Alarm ON
1
1
AIC (Alarm Indication (Cancel)
1
1
Note :
a) The open collector transistor capacity : 24 V DC, 40 MA

4 Pumps
System
4

5 Pumps
System
5

4
HLL, LL & RST
4

5
HLL, LL & RST
5

4
1

5
1

2
4
4
1
1

2
5
5
1
1

b) LED indications are available on BPC for HL, LL, Pump Trip, AIC

*Pumps are switched off Sequentially as


per decrease in demand. Role of Stand-by
pump is rotated in each next cycle to ensure
equal running of all pumps.
HL
IND

24VDC

LL
IND

TRP1 TRP2 TRP3


IND IND IND

A/C
IND

ALARM

ALARM

IND

COM NO

PUMP
PUMP1
1IND COM NO

PUMP
PUMP2
PUMP PUMP3
2IND COM NO 3IND COM NO

BOOSTER PUMP CONTROLLER (3 PUMP) TIMING DIAGRAM


CYCLE 1

STAGE

POWER
ON

01

02

03

CYCLE 2
02

01

01

02

03

CYCLE 3
02

401

01

02

03

OUTPUT

PS 1
PS 2
PS 3
T1

T1

SB

PMP1
T2

T2

T2

PMP2
T3

PMP3

SB

SB

T3

SB

T3

TRP1
TRP2
TRP3
LL
RST
AIC

INPUT

HL
ALARM

HL

MUTE

ABBREVIATIONS USED
PS1 : PRESSURE SWITCH1

TRP1 : PUMP1 TRIP

LL : LOW LEVEL

PMP1 : PUMP 1

T1 : OFF DELAY FOR PUMP1 (1-15 SEC)

PS3 : PRESSURE SWITCH3

TRP2 : PUMP2 TRIP

RST : RESTART LEVEL

PMP2 : PUMP 2

T2 : OFF DELAY FOR PUMP2 (1-15 SEC)

PS2 : PRESSURE SWITCH2

TRP3 : PUMP3 TRIP

HL : HIGH LEVEL

PMP3 : PUMP 3

T3 : OFF DELAY FOR PUMP3 (1-15 SEC)


SB : STANDBY PUMP

LL RST

TRP1 TRP2 TRP3

PS 1 PS 2

PS 3 MUTE AM 1 AM 2

AM 3

GND GND

AC 20V IN

AUX.
SUPPLY

43

PROCESS / PLANT MONITORING & CONTROL


MINISCADA

Telecom Line

Remote Monitoring PC Terminal

Modem

Remote Base Station

Converter

Local Control
PC Terminal

RS
232

RS
485

Modem

RS 485
RS 232

SCADA system is useful for Remote Monitoring and control of various


equipments used in building or factories or manufacturing plants.
Suitable software is developed considering input - output signals & functions

The scheme of Remote Monitoring SCADA


System will consist of :

SCADA hardware-Signal Conditioning


& Processing of inputs

Local LCD display module

RS 485 port output

Interface Converter RS 232 - RS485


port and vice versa

Dedicated Computer Terminals

Remote Monitoring For Building Facilities

Customized Solutions for Pump


Houses, DG Sets, Mains supply

Single Source for SCADA Hardware &


PC Software

Secured Access by Passwords

Event Logging & data analysis

On Line Reports / Charts

Supervision & commissioning services

Application areas
Pump Automation & Remote Monitoring

Local time based pump operations &


remote control function

Time based event logging.

Interlinking of multiple pump


controllers through RS 485
communication

Optional Modem base dial up


interlinking through PC

Windows based GUI software

Status Monitoring & Intelligent Control of


AC Plants, Power Houses

Multiple 3 phase Air Conditioning Units

Multiple Single phase Air Conditioning


Units

Diesel Generator Sets & AMF Control

Air
Conditioning
Plant

Pumping
Station

Power
Generation Set

Fire
Alarm
System

Motor &
Pump

Distribution
Sub-station

Standard configuration of MINISCADA has following basic


specifications:
Control Supply - 90 - 270 V AC / DC
Digital Inputs

- 32 max.

Digital Outputs - 16 max.


Analog Inputs

- 6 max.
- Room Temp. - PT 100 / RTD
- DC Current (4-20 mA)
- DC Voltage (0-10 V)
- DC Voltage (0-140 V DC)
- DC Shunt Current (0 - 10 A)

Communication Port

- RS 232 / RS 485

Communication Protocol

- Modbus ASCII

Keyboard & Display

- 4 Keys

Weight

- 7200 gms (approx.)

16 x 2 alphanumeric Display

HT / LT Substation Monitoring

Breaker status monitoring & control

Winding temperature, gas pressure, oil


temperature monitoring

Digital and analog inputs

Measurement and remote display of


voltage, current, power, battery
charger current and voltage.

Windows based GUI software

Dimensions (mm) 19" Rack - 3U x 75 HP x 260


(436.88 x 132.50 x 260)
Facia

144 x 72 x 70
(W)

(H)

(D)

Power Consumption - 30 W max.

KBD - LCD FACIA MODULE

MENU

MINISCADA

MINISCADA
CPU
LCD
CON3

MINISCADA
ANALOG
I/Ps - 1

MINISCADA
ANALOG
I/Ps - 2

MINISCADA
DIGITAL
I/Ps - 1

MINISCADA
DIGITAL
I/Ps - 2

IP 1

IP 17

MINISCADA
DIGITAL
O/Ps - 1

COM8

COM1

IP 2
AMBIENT
TEMPERATURE
(AD 590)

0 - 10VDC

C
IP 3

DUMMY

DUMMY

IP 4
110VDC
VOLTAGE

TEMPERATURE
(PT 100)

CON2
RS -232

C
IP 5

DUMMY

IP 6
DUMMY

DC - mV
(SHUNT)

4 - 20mA

IP 7
DUMMY

IP 8

CON4
DATA +
DATA EARTH
CON1
RS-485

44
COMPUTER

CON5

CON10

IP 9

IP 18

IP 10

IP 19

IP 11

IP 20

IP 12

IP 21

IP 13

IP 22

IP 14

IP 23

IP 15

IP 24

IP 16

CON11

CON12

MINISCADA
SMPS

NO1

IP 25

COM2

IP 26

NO2

COM3

IP 27

NO3

IP 28

COM4

NO4

IP 29

COM5

IP 30

NO5

COM6

IP 31

NO6

IP 32

COM7

NO7

CON13

NO8
COM9

HEALTHY

NO9
COM10

AUX.
SUPPLY

NO10
COM11
NO11

NO12

ON

COM13
NO13

CON8

MAINS

COM14
NO14
COM15
NO15
COM16

CON20

OFF

/
/

COM12

FUSE

NO16

CON21

ALARM ANNUNCIATORS
Minilec Microprocessor Based Alarm Annunciators are designed to keep an alert & watchful eye on your plant & processes. The entire
range has been designed with an insight into the modern day manufacturing plant & its future requirements. Minilec Alarm Annunciators
are equipped with microprocessor-based design, super bright LED facia windows, site selectable, programmed sequences as per ISA
standard & thoughtful provisions for troubleshooting & maintenance. Dynamic, Alert & Responsive These unique advantages have
helped the Minilec Annunciators to be an icon in the power T & D industry & engineering establishments in India. The world class Minilec
Annunciator has made its presence felt in Overseas markets.
MICROPROCESSOR
BASED SYSTEM
TWO DIFFERENT
WINDOW SIZES
LEGEND
REPLACEABLE

WATCH
DOG
LED

SITE
SELECTABLE
E ES
UC
SEQN

STANDARD
CONNECTING
CABLE
MAX . 3mt.

SITE
SELECTABLE
NO / NC

WELCOME
TO
X 8
IMTE9

COMPUTER
LINKING

SMPS
MODULE

GROUPING
FACILIYT

MODELS :

FEATURES

MICROWARN 0600,
MBAS 0600,
MBAS 9700,
MBAS 9900,
Accessories,
Annunciation Panels

4 windows to 128 windows


Integral & Split models
Microprocessor based
Super bright LEDs for facia
Standard operating sequenses
Any other custom- made sequenses
NO-NC & Trip Non-Trip site selectable
Repeat relays
Supply fail annunciation / Indication
Choice of 3 window sizes
Choice of five colours

Ordering Instructions
Product Family Name
Model Name
Aux. Supply / Control supply
voltage
No. of Inputs (Windows)
Operating sequence
45

ALARM ANNUNCIATORS

The Undisputed Leader


Many pioneering advancements have been introduced for the first time by
Minilec in the Indian market. The Minilec range is equipped with well researched
and innovative features highly appreciated by consultants and customers (and
imitated by competitors !)
Some of the trend setting technologies and features initiated by Minilec are as
follows :
Microprocessor based system operation :
For robust design and easier troubleshooting.
ISO 9001 standards : For high standards of quality assurance and
reliability.
LEDs for facia : For lower maintenance costs, long life and low energy
consumption.
Multi coloured windows : For simplified fault differentiation.
Standard modules : For seamless integration and better aesthetics.
Moulded enclosure : For space savings and improved aesthetics.
Easily accessible DIP switches : For faster programming by eliminating
the need to open the unit.
Any operating sequence : For added flexibility and convenience.
Serial communication : For computerised fault detection and automatic
documentation.
Solutions for Varying Needs
The Minilec range of annuciators is highly diversified and adaptable to a wide
spectrum conditions. Be it a Power station, Sub station, Sugar factory, Steel
plant, Fertiliser / Petrochemical plant, ships and dockyards, railways or for that
matter, any process plant. Be it in the hot summers of Rajasthan, Egypt of
Indonesia or the humid atmosphere of Clacutta, Chennai or Malaysia, Minilec
takes it all in its stride !
The Product Range
MICROWARN 0600 - Standard models for 6,8,12 points
MBAS 0600 - Standard models for 4-16 points
MBAS 9700 - Standard models for 16, 32, 48, 64, 80, 96 point
MBAS 9900 - Standard models for 4, 6 & 8 points
The Advant -edges
Advantages of Microprocesor Based Alarm Annunciators over solid state version
Less components hence high reliability.
Compact size, light weight.
Low power consumption.

46

Flexibility - any operating sequence can be provided.


Being the latest in technology, can be configured easily with any other
advanced system.
The Unique Features
Powerful microprocessor based circuit.
Built in system watch dog.
First fault identification.
Optically isolated fault inputs.
Wide range of site selectable alarm sequences (ISA standards)
Facia with super bright LEDs instead of high power consuming short life
filament lamps.
Site selectable fault contact filament lamps. Site selectable fault contact
configuration (NO/NC).
Special SMPS power supply.
Sleek, modern, aesthetic design.
Additional Features
Grouping feature for differentiation between Trip / Non - Trip type faults.
Repeat relays for parallel annunciation.
Supply fail annunciation / indication.
Manned / Unmanned feature.
Parallelling of units.
Group fault alarm.
Choice of three window colours : Red, Green, Amber (Yellow).
Reliability
Minilec annunciators have been tested satisfactorily at CPRI (Bangalore), SISIR
Singapore, ERTL, ETDC for environmental and functional tests as per relevant
standards.
Upon request available with CE marking.
All Alarm Annunciator carry 5 yrs. warrantee.
The Highlights
MBAS series with replaceable windows, 2 window sizes, DIP switches
outside for easy programming
Common power supply 90-270 AC/DC and DIP switches outside for
Microwarn 0600 models.
Split architecture - economic/cost saving, for 19'' rack concept for MBAS
9700 models.
Serial port - RS232C / RS485 for MBAS 9700 models.

A L A R M

A N N U N C I A T O R S
MICROWARN 0600
*

12 Windows Model

TECHNICAL SPECIFICATIONS :

This is a modified version of earlier Microwarn 9600 model


which has been discontinued. Microwarn 0600 consists of 3
basic sections :
Microwarn O600 is now more compact than before with
reduced depth. Also it can have 3 rd output relas for extra
funcation
A
(A) The Power Pack
(B) The CPU
C
(C) The Facia,

Response Time

25 msec. 10 msec.

Input Signal

Potential free contacts (NO or NC site selectable)

Interrogation Voltage

+ 12 V DC

Output Contacts

1 NO + 1 NO (optional) + 1 NO ( Optional)

Architecture

Integrated

Operational Seq.

ISA Standards sequences - Auto/Manual/First-up/Ringback (optional) OR


any other sequence on request

Operational Temp.

0-600C

Power Consumption

1.5 Watts per Window (Max.)

Optional

Grouping / AC-DC fail Annunciation

Dimensions (mm)
Panel Cutout (L x W)
Overall (L x W x D)

153 x 203
166 x 216 x 82

Wherever not specified Contact Rating : 5A @ 230 V AC (resistive)

* CE marked products available on request.

Dimensional Details
166mm
216mm

F1

F2 F3

F1

F2

F3

F4

F4

F5 F6

166mm F5

F6

F7

F8

F7

F8 F9

F10 F11 F12

216mm

203mm

153mm

F10 F11 F12

AUX. SUPPLY

~/ - VE
~/ +VE

RLY-3

CON4

NO3
E

RLY-2

NO2
COM3

COM2

CON3

NO1

RST

ACK
CON2

SILENCE

TEST

F12

F11

F10

F9

F7

F8

CON1

F6

F5

F3

F4

F1

F2
C

NO/NC or sequence selection DIP switches are located outside,


hence programming is now possible without opening the unit.
Models of 12, 8, 6 windows are available. 8 and 6 window models
are with built-in push buttons.

COM1

RLY-1

}
}
}

RPB

Typical Connection Diagram


SPB
APB

82mm

Panel Cutout
RRC NETWORK

Panel Cutout

Vertical

RRC NETWORK

Horizontal

RRC NETWORK

F9

153mm
203mm

TPB

C) The Facia :
This section consists of facia windows illuminated by Super Bright
LEDs on occurrence of any fault. The Super Bright LEDs ensure a
long and absolutely maintenance free window life along with a good
visibility, and have very low power consumption.
.

Front Replaceable

B) FACIA.
D) C COVER.
F) DIP SWITCH.
H) FUSE
J) RELAY OUTPUT.
L) SMPS + CPU CARD.

B) The CPU :
This is the Central Processing Unit of Microwarn 0600 which scans
and processes the incoming fault signals from the various potential
free field contacts and drives the corresponding LED windows and
the audible devices in order to announce the fault, according to the
operating sequence selected.

Super bright high efficiency low power consuming LED's

Facia Type

216

A) The Power Pack :


The Microwarn 0600 is powered by a highly reliable and noise free,
specially designed power supply. It converts the available power
source (AC/DC voltage supply) into a regulated and filtered DC
output, which is fed to the annunciator unit.

45 x 45 mm

Display Device

Standard colour available RED, Optional colours Yellow / Amber, Green

NOTES :J
I
A) COVER MOUNTING SCREWS.
C) TERMINAL STRIP FAULT INPUT.
E) LED BOARD.
G) POWER SUPPLY CONNECTOR.
I) SLOT FOR MOUNTING CLAMP.
K) TERMINAL FOR EXTERNAL PUSH BUTTON.

12/8/6

Window Sizes

Fast - 60 flashes/min. Slow - 30 flashes/min.

G
F

24/30/48/ V DC 90-270V AC/DC+10% 15%

Window/LED Colour
D

82

Supply Voltage
Windows

Flash Rate

16
6

8 Windows Model
with push button

Now with
Reduced depth

47

A L A R M

A N N U N C I A T O R S
*

MBAS 0600

1D

1D
LOW
POWER
CONSUMPTION

1D

2D

POSITIVE
TYPE

MICROPROCESSOR
BASED SYSTEM

LEGENDS
STANDARD
CONNECTING
CABLE
MAX . 3mt.

COMPUTER
LINKING

INPUT
OPTOISOLATED

SITE
SELECTABLE
NO / NC

14B0S00

TWO DIFFERENT
WINDOW SIZES
LEGEND
REPLACEABLE

WATCH
DOG
LED

SMPS
MODULE

10B8S00

10B6SP0

SIET
SELECTABLE
SEQUENCES

2D
STANDARD
CONNECTING
CABLE
MAX . 3mt.

SIET
TA LE
SELECB
NO / NC

COMPUTER
LINKING

SMPS
MODULE

WELCOME
TO
IMTEX 98

GROUPING
FACILIYT

22B10SP0

20B16S00

MBAS 0600 is a improved version of earlier MBAS 9400, and is available for 4 to 24 windows
The Functional Features
Fixed Sequence ( S1/S2/S3/S4)
Sequence as per ISA standard
Potential free dry contact inputs
NO/NC inputs grouping selectable
configuration
Relay output for external Audible Hooter
3rd Relay optional for either of below
mentioned features
a) Ring back hooter
b) Supervisory control

The Design Features


Single chip microcontroller logic
Opto isolated inputs and outputs
Super Bright LED window illumination
High Noise immunity / isolation
Switch mode power supply
Self surveillance watchdog LED

System Enclosures
The MBAS 0600 annunciation systems is configured in multiples
of four basic ABS moulded enclosures
Size 1 D

Size 2 D

The Constructional Flexibility


Conforming to DIN panel cutouts
Replacable snap-on window capsules
Two different window size
Expandable modules
Moulded enclosures

Size 3 D

Size 4 D

Basic Standard Enclosures

Functional Block Diagram

Back view showing Terminal details

Part names & locations

Optional Features

Site Selectable sequences (S1, S2, S3, S4 )


Pre-pogrammed Custom built operating sequences
Trip & Non-Trip grouping facility for MBAS 0600
Manned / Unmanned function
Fault Follower contact output per fault Input (NO or NC)
Ringback sequence with optional 3rd relay output for
Ringback hooter, with Trip & Non-Trip grouping facility
Supply fail indication / annunciation
External and / or built-in control push buttons
48

A L A R M

A N N U N C I A T O R S
*

MBAS 0600

3D

4D

312B0S00

416B0S00

30B24S00

Connection Diagram

2D

28B0S00

TECHNICAL SPECIFICATIONS :

(FOR MAX. 24 POINT MBAS 0600.)

Supply Voltage

24 / 30 / 48 / V DC 90 - 270 V AC / DC

F1

Windows

4 / 6 / 8 / 12 / 16 / 18 / 22 / 24

F2

Window Sizes

30 x 30mm / 30 x 65 mm

F3

Display Device

Super bright high efficiency low power consuming LED's

F4

Facia Type

Individual windows front Individual windows / Front Replaceable

F5

Window/LED Colour

Standard colour available RED, Optional colours Yellow / Amber, Green

F6

Flash Rate

Fast - 60 flashes/min. Slow - 30 flashes/min.

F7

Response Time

25 msec. 10 msec.

Input Signal

Potential free contacts (NO or NC site selectable)

F8
C
F9
F10
F11

Interrogation Voltage

+ 12 V DC

Output Contacts

1 NO + 1 NO (Optional) +INO (optional)

Architecture

Integrated

Operational Seq.

F12

ISA Standards sequences - Auto/Manual/First-up/Ringback (optional) OR


any other sequence on request

F13

Operational Temp.

F14
F15
F16

0-60 degrees C

Power Consumption

1.5 Watts per Window (Max)

Optional

Grouping / AC-DC fail Annunciation / Repeat Relay cards

Dimensions (mm)

1D

Panel Cutout (L x W)

F17
F18

Overall L x W x D

F19

2D

138 x68

3D

138 x 138

144 x 72 x 215

138 x 210

4D
138 x 282

144 x 144 x 215 144 x 216 x 215 144 x 288 x 215

Wherever not specified Contact Rating : 5A @ 230 V AC (resistive) * CE marked products available on request.

F20
F21

Dimnesional & Panel Cutout Details

F22
F23

72
F1
F2
F3
F4

144

F1
F2

F5
F6

F1
F2

F5
F6

F3

F7

F3

F7

F4

F8

F4

F24
C
TEST

TPB

MUTE

MPB
APB

ACK

I3
C3
I2
C2
I1
C1

/+VE
/ - VE

RLY-3
RLY-2
RLY-1

}
}
}

F5 F6

F5 F6

F7 F8

144

144

RRC NETWORK

72
F1 F2
F3 F4

1D

RPB

RST
C

72
F1 F2
F3 F4

2D

RRC NETWORK

144

216

144

RRC NETWORK

3D

144

216

F1 F2 F9 F10
F3 F4 F11 F12
F5 F6 F13 F14
F7 F8
216

F1
F2

F5
F6

F9
F10

F1
F2

F5
F6

F9
F10

F3
F4

F7
F8

F11
F12

F3
F4

F7
F8

F11

F1 F2 F9
F3 F4 F11
F5 F6 F13
F7 F8 F15

F10 F17 F18


F12 F19 F20
F14 F21 F22
F16

AUX. SUPPLY
288

E
144

4D

A1

F1
F2

F5
F6

F9
F10

F13
F14

F3
F4

F7
F8

F11
F12

F15
F16

U/M
A2
SW

49

A L A R M

A N N U N C I A T O R S
MBAS 9700

Integral Model : 16 Pts. Small

Integral Model : 16 Pts. Big


STANDARD FEATURES
Single chip micro-controller logic. Super
bright LED's for window illumination. Site
selectable NO/NC type fault contacts. Site
selectable trip /Non trip (Grouping). Easy card
replacement & hence fault diagnosis. Switch
Mode Power Supply. (Suitable for Both AC/DC
Supply) High noise immunity and wide input
supply variation. Opto-isolated Inputs and
Outputs. Site Selectable sequences. Potential
free dry input contacts. Two different window
sizes. Replaceable windows & window
legends. Computer linking for fault logging with
printer facility for report.Self-surveillance
watch dog LED. Relay output for external
audible hooter. Diagnostics Menu Redundant
Power Supply (Only in 19 Rack Model) CPU
fail & PSU fail indication with relay output contact
(Only in 19 Rack) User Friendly terminal
Connectors

CONSTRUCTIONAL DETAILS
MBAS 9700 consist of four
OPTIONAL FEATURES
basic sections (in 16 point
Different colored LED's in each
moulded enclosure these are
window for easy differentiation
inbuilt)
MINILEC
of critical faults.
offers its unique alarm
1) The Power Supply Uni (PSU
Annunciator based on the latest single
Customized preprogrammed
Module).
chip micro-controller technology with serial
operating sequence.
2) The Main Control Unit
communication facility. Now available in both 19 rack
Multi channel serial
(CPU + IOU Module).
type enclosure as well as in moulded enclosure. MBAS 9700
communication
3) The Display Facia Unit
annunciators have split architecture for 16, 24, 32, 48, 64, 80,
(8 Annunciators & single
(DFU Module).
96,112 & 128 windows and integral type of architecture for 16
computer)
4) Computer interface.
small or big window models. 24, 32, 48, 64, 80, 96,112, & 128
window models are housed in 19 rack type enclosures, separate for
MCU & for PSU. Here choice of facia (DFU) is of 3 types (a) Small size i.e.
30 x 30 mm and (b) Big size is 30 x 65 mm / 50 x 70 mm. (c) Facia is
available in multiples of 16 windows. In addition to all other standard
features, MBAS 9700 has additional facility of computer linking. A
THE DISPLAY FACIA
THE MAIN CONTROL
serial port (RS232C /RS485) output is available which can be
UNIT (DFU)
UNIT (MCU)
supported by an IBM compatible PC of minimum 386
T h e Fa c i a b l o c k i s
CPU module is the Main
configuration. Minilec can supply the standard software with
accessible from front (in
Processing Unit of MBAS
every model or can develop suitable software as per
moulded enclosure) and
9700 which scans and
customer requirements or can provide source
constitutes of
window
processes the incoming fault
coding / protocol details to enable client to
capsules. The sandwiched
signals from the various
develop their own suitable
software.
photo film window inscriptions
potential free field contacts

50

through IOU module, and drives


the corresponding LED windows
and the audible device in order to
annunciate the fault through IOU
module. The IOU module is the
input & output interfacing unit.
To each IOU module 16 input
contacts (potential free) & 16
window LED's can be
connected.

THE POWER SUPPLY UNIT (PSU)


PSU converts the available power source into a
regulated and filtered DC output, which is fed to
the MCU Module & DFUs. The power supply can
accept Specified AC or DC I/P supply, depending
upon the application.

are press fitted on the window


capsules.
For 16 to 128 points system the
DFUs are given separately,
except 16 point (moulded
Enclosure) where it is in built.

A L A R M

A N N U N C I A T O R S
MBAS 9700
16 Pt. DFU Big Windows

16 Pt. DFU Big Windows

16 Pt. DFU Big Windows

MCU Rack

PSU Rack

16 Pt. DFU : Small Windows


COMPUTER INTERFACE
The MCU unit transmits fault information to computer serially. RS 232C/RS
485 standard is used for serial communication. Communication protocol
modbus ASCII / RTU can be offered. In computer user-friendly software is

TECHNICAL SPECIFICATIONS:

written. This software offers on-line Date & Time setting, Legend setting,

1.0

Supply voltage

20 - 60VDC, 90 - 270VAC/DC

Display window & also it gives fault report with on demand printing facility.

2.0

Supply frequency

50 / 60 Hz. (3%) for AC

3.0

Input

3.1

Fault Alarm Inputs.

Actuation Through Fault Contacts

3.2

Fault contacts.

Potential free (volt free) type

3.3

Input interrogation voltage

+12V DC(ISO)

3.4

Input isolation

Opto isolating device.(2 KV)

3.5

Response Time

40 mS.

3.6

Site selectable DIP for

4.0

Dimensional Details for Facia

144

F5
F6
F7
F8

F9
F10
F11
F12

F13
F14
F15
F16

NO/NC

Grouping

Trip/Non Trip

Sequence selection

Manual/Auto/Ringback/Firstup

Output

4.1

Output contacts for grouping

1NO+ 1NO

4.2

Output contact for CPU & PSU fail

1NC (In 19" Rack Only)

4.3

Contact Rating

5 amp at 240 VCA (Resistive)

5.0

No. of windows

288

F1
F2
F3
F4

Fault type

In 19 " rack

16/24 Big/32/40 Big/48/64/80/96/112/128

In 9400 enclosure

16 points

5.1

Windows dimensions

30 mm x 30 mm For small windows

5.2

Colour

Red / (Yellow {Amber} / Green)

65 mm x 30 mm For big windows

Flash rates
282

5.3

50-60 flashes / Min


25-30 flashes / Min.

16 Pts. Annunciator
or 16 Pts. Facia
Big Windows

For Ring Back Sequence or other seq.

138

5.4

Power Consumption

1.5 W per Window. (Max)

6.0

Sequence

Manual Reset, Auto Reset, Ring back, Firstup

Panel Cutout
144
F1 F2
144

(Any Other Sequences On Request)


138

7.0

Serial communication

RS232C / RS485 with modbus ASCII / RTU

F9 F10

F3 F4 F11 F12
F5 F6 F13 F14

16 Pts. Ann
or 16 Pts. Facia 138
Small Windows

51

F7 F8 F15 F16

Panel Cutout

ALARM ANNUNCIATORS - MBAS 9700

DIMENSIONAL DETAILS - MCU & PSU


D

Overall Dimenssions ( DFU )

MCU
FRONT VIEW

MUC
SIDE VIEW

MODELS
PSU
FRONT VIEW

PSU
SIDE VIEW

7.0

10.0

128 POINT
112 POINT
96 POINT
80 POINT
64 POINT
48 POINT
32 POINT

C
B

MODELS

MOUNTING DIMENSIONS

128 POINTS

Big Windows

144m.m.
144m.m.
144m.m.
144m.m.
144m.m.
144m.m.
144m.m.

2304m.m.
2016m.m.
1728m.m.
1440m.m.
1152m.m.
864m.m.
576m.m.

70m.m.
70m.m.
70m.m.
70m.m.
70m.m.
70m.m.
70m.m.

OVERALL DIMENSIONS

Small Windows

57.15

465.10

292.38

482.60

260.00

132.50

310.38

112 POINTS

57.15

419.38

292.38

436.88

260.00

132.50

310.38

96 POINTS

57.15

373.66

241.58

391.16

260.00

132.50

259.58
259.58

80 POINTS

57.15

327.94

241.58

345.44

260.00

132.50

64 POINTS

57.15

434.62

--------

452.12

260.00

132.50

--------

48 POINTS

57.15

388.90

--------

406.40

260.00

132.50

--------

32 POINTS

57.15

292.38

--------

309.88

260.00

132.50

--------

128 POINT
112 POINT
96 POINT
80 POINT
64 POINT
48 POINT
32 POINT

PANEL CUTOUT DETAILS - DFU

144m.m.
144m.m.
144m.m.
144m.m.
144m.m.
144m.m.
144m.m.

1152m.m.
1008m.m.
864m.m.
720m.m.
576m.m.
432m.m.
288m.m.

Small Window

138mm

138mm

6mm

Big Window

138mm

282mm

6mm

70m.m.
70m.m.
70m.m.
70m.m.
70m.m.
70m.m.
70m.m.

128pt
112pt
96
80
64
48
32

EXTERNAL WIRING DIAGRAM WITH REPEAT RELAY


CON2

CON3

DFU3

DFU2

DFU1
REPEAT RELAY
CARD - 1
CON2A

CON5

CON4

REPEAT RELAY
CARD - 2
CON3A

CON6

DFU5

DFU4

REPEAT RELAY
CARD - 3
CON4A

CON7

REPEAT RELAY
CARD - 4
CON5A

CON8

DFU6

DFU7

REPEAT RELAY
CARD - 6
CON7A

REPEAT RELAY
CARD - 5
CON6A

CON9

DFU8
REPEAT RELAY
CARD - 8
CON9A

REPEAT RELAY
CARD - 7
CON8A

OFF

OFF

OFF

OFF

OFF

ON

ON

ON

ON

ON

CON10

CON10
CON1
CON2

CON2A

IOU-1

CON3

CON3A

IOU-2

CON4

CON4A

IOU-3

CON5

CON5A

IOU-4

CON6

CON6A

IOU-5

CON7

CON7A

IOU-6

CON8

CON8A

IOU-7

CON9

CON9A

TO
MAINS
PSU-1

IOU-8

MCU MODULE

FOR CUSTOMER

COMPUTER

52

PSU-2

PSU-3

PSU-4

PSU-5

PSU MODULE

A L A R M

A N N U N C I A T O R S

MBAS 9900

MICROFACIA
These are LED Facia
windows with Potential
input or potential free
input. Microfacia is
available in either 4 Big
or 8 Small windows
size. Standard models
available for 12V/24V DC
and 110V/230V AC.

1 0B 6S PB

MF951

1 0B 4S PB

MF955

MBAS 9900 screens Annunciator accepts 12 / 24 V DC potential


input & also provides control relay output. Added built-in buzzer &
push buttons makes it complete Annunciator with control output.
This output is interlocked until all fault input resets. MBAS 9900 is
presently available in 4 point & 6 point small window (30 x 30mm)
configuration. Both 4 point & 6 point systems come with built-in
push buttons.

Microfacia are LED window assemblies for RUN, TRIP or


FAULT indications. With microfacia windows the panel
designers can improve aesthetic value to the panel indications
in a Row / Column format. Microfacia is useful for direct
operation with AC or DC voltage

Technical Specifications :

Technical Specifications :

PARAMETERS

PARAMETERS

Supply Voltage

230 V AC / 110 V AC, 12 V / 24 V DC +10% -15%

Windows

4/6/8

Auxiliary Supply *

12 / 24 / 110 / 220 V AC / DC
Potential Free Contacts or Potential Contact
Window Facia LEDs on front

Window Sizes

30 x 30 mm

Input

Display Device

Super bright LED's

Output

Facia Type

Individual Windows Front Replaceable

Window/LED Colour

RED, Yellow / Amber, Green

Flash Rate

Fast - 60 flashes/min. Slow - 30 flashes/min.

Response Time

25 msec. 10 msec.

Input Signal

+12 V or 24 V DC Contact

Output Contacts

1 CO + 1 CO

Architecture

Integrated

Operational Seq.

Sequence as mentioned in text

Operational Temp.

0-600C

Power Consumption

1.5 Watts per Window

Window /LED Colour

RED, Amber / Yellow, Green

Power Consumption

1.5 Watts per Window

Dimensions (mm) Unit

Overall (L x W x D ) (w/o PSU 144 x 72 x 80)

Dimensions (mm)Window

for Small 30 x 30, for Big 62 x 30

Weight (Approx.)

700 gms. (With PSU)

(With PSU) 144 x 72 x 215

250 gms. (W/o PSU)


* Applicable only for Microfacia with potential free inputs.

Wherever not specified Contact Rating : 5A @ 230 V AC (resistive)

Operating sequence table - MBAS 9900


MANUAL
ACTION
VISUAL
AUDIO(N)

N
P.B. TEST
DEP
F
ON

ABN

REL
OFF F
OFF ON

ABBREVIATIONS
N
ABN
RN.
RABNS

RN R-ABN

OFF
OFF

F
ON

:
NORMAL
ABNORMAL
RETURN TO NORMAL
RETURN TO ABNORMAL

N
ABN
SILENCE
N. A.
F
N. A. OFF

N. A.
N. A.

S
OFF

R-ABN
BEFORE

N ABN
RESET

RESET
S
OFF

OFF F
OFF ON

S
OFF

68 mm

F C
6 2
F
5

144 mm

Connection Diagram

Connection Diagram
Fault
Inputs

F1 F2
F3 F4

R-N

S STEADY ON
NORMAL BUZZER
DEPRESSED
RELEASED
NOT APPLICABLE
FLASH

AUDIO(N)
DEP.
REL.
N.A.
F

Dimensional Details
72 mm

N
ABN
ACCEPT

C
O
M

138 mm

F5 F6

N
O
2
N
C
2

Output
Relay 2

F C
4 1
F
3
F
2

Panel Cutout
72 mm

Output
Relay 1

N
O
1
N
C
1

F D
1
T
E
S
T
M
U
T
E

144 mm

A
C
K
R
S
T

215 mm

C
TM1

TM1

/+

Aux. Supply
/-

TM2

F8
F7
C
F6
F5
C
F4
F3
C
F2
F1
C
-VE
Aux. Supply
+VE

W8

Dimensions
66

W7

W6
W5

W4
W3

W2
W1

A
A
A
A
A
A
A
A

F8
F7
F6
F5
F4
F3
F2
F1
-ve

W8

W7

144

W6
W5
W4
W3

Unit
Panel

W2
W1

Panel Cutout
68

TERMINAL STRIP

138

TM2

FUSE

Potential-Free
Fault Inputs

Potential
Inputs

REAR
VIEW

53

A L A R M

A N N U N C I A T O R S
ANNUNCIATOR PANELS

Often Alarm Annunciators are required assembled housed in a suitable


control cubical. The control panel consists of only Alarm Annunciators.
Minilec offers Alarm Annunciators along with control panels. This includes
design of control panel, fabrication, painting, assembly of Alarm
Annunciators and assistance during installation and commissioning.
Retrofitting work by replacing old annunciation system with latest design
and for expansion in power stations, substations, process plants as also
standard Annunciation Panels for plants and equipments can be catered to.
The Minilec Panel Advantages
Complete in-house design, assembly of Annunciator Panels.
Software capability for automisation to meet project specifications.
Component layout as per standards & safety requirements.
Powder coated MS or Aluminum Rack Panels with quality panel wiring.

54

A L A R M

A N N U N C I A T O R S

STANDARD OPERATING SEQUENCES

The MINILEC Annunciation systems are programmed to


operate as per following operating sequences confirming to ISA
standards. Other sequences / non standard sequences are given
as per customers requirement.
Minilec
Sequence Code
S1
S2
S3
S4

Operating
Sequence Title
Manual Reset
Auto Reset
Ringback
First UP

OPTIONAL ACCESSORIES

Repeat Relay Card


External Repeat Relay Cards can be connected for remote annunciation or
interfacing with SCADA or DCS hardware. These cards are connected by
plug-in type pre-fab cables.

ISA Std. Code


M1
A1
R1-12
F2M-1

SEQUENCE S1 : Manual Reset (M1)


P NORMAL
RESET WHILE
NORMAL

V OFF

TO ABNORMAL

A SILENT
P ABNORMAL

P ABNORMAL
ACCEPT

/ NORMAL

/ NORMAL
/ TEST

V STEADY

V FLASHING

A SILENT

A AUDIBLE

P ABNORMAL
/ NORMAL

ACCEPT

1. Test, Silence Accept,


Reset Push Buttons are
external.
2. Audible alarm can be
silenced by pressing
Silence (Mute) Push
button.
3. Manual reset of Accepted
faults after process
conditions return to
normal.
4. Operation test provided.

Mounting & overall Dimmensions of


External Repeat Relay Card (8/16 Relays)
4-

3.0
25
85
50

10

180
190

SILENCE / MUTE

V STEADY

Supply Fail Annunciation

A SILENT
11 10

SEQUENCE S2 : Auto Reset (A1)

C3

V OFF

TO ABNORMAL

A SILENT
P ABNORMAL

P ABNORMAL
ACCEPT

V STEADY

/ NORMAL
V FLASHING

A SILENT

A AUDIBLE

P ABNORMAL
/ NORMAL

ACCEPT

TOP VIEW OF RELAY ( R1 )

NO3 NC3 NO2

COIL

P NORMAL
RESET WHILE
NORMAL

V STEADY

1. Test, Silence Accept,


Reset Push Buttons are
external.
2. Audible alarm can be
silenced by pressing
Silence (Mute) Push
button.
3. Automatic reset of
Accepted faults after
process conditions return
to normal.
4. Operation test provided.

R1

C1

NO1 NC1 NC2 C2

10

C3

11

C1

COIL
NO1
UNIT-1

8
7
6

4 5

NO3
NC3
NO2
C2
NC2
NC1

SF 1
SF 2

P11

P1 2

P2 1

P2 2

STAND BY SUPPLY
UNIT-1

+VE

SILENCE / MUTE

A SILENT

- VE

NORMAL SUPPLY

SEQUENCE S3 : Ringback (R1-12)


P NORMAL
RESET WHILE
NORMAL

V OFF

TO ABNORMAL

A OFF
RB SILENT

P ABNORMAL
V SLOW

P ABNORMAL
V FAST

RETURN TO NORMAL

FLASH
A OFF
RB AUDIBLE

FLASH
A AUDIBLE

RETURN TO ABNORMAL

RB SILENT

P ABNORMAL
RETURN
TO NORMAL

V STEADY

1. Test, Silence Accept,


Reset Push Buttons are
external.
2. Alarm & ringback Audible
devices.
3. Audible device or ringback
alarm can be silenced by
pressing Silence (Mute)
Push
button.
4. Ringback visual & audible
alarm when process
status returns to normal.
5. Operation test provided.

ACCEPT
WHILE ABNORMAL

A SILENT
RB SILENT

This feature enables the


annunciator to operate on
alternate stand-by power
supply in case of mains
supply failure. External relays
with separate power supply
module is supplied. If mains
supply and stand-by supply
are of same voltage level the
power supply module is not
required.

Manned / Unmanned Facility


This feature allows disabling the audio
& visual indication on fault occurrence if
the station is unmanned. The
annunciator registers & records all
faults occurring during unmanned
mode and displays again manned
mode.

M
A1
U/M
A2
S

SEQUENCE S4 : First Out Manual Reset


P NORMAL
RESET WHILE
NORMAL

V OFF

FIRST TO
ABNORMAL

A SILENT
P ABNORMAL
V STEADY
A SILENT
ACCEPT

P ABNORMAL

MUTE

/ TEST
V FLASHING

P ABNORMAL

1. Test, Silence Accept,


Reset Push Buttons are
external.
2. First-out flashing and
subsequent steady.
3. Manual reset of Accepted
faults when process
status return to normal.
4. Operation test provided.

A AUDIBLE

V STEADY
A AUDIBLE

P ABNORMAL
V FLASHING

This is a universal convertor for converting RS 232 serial


port to RS 485 serial port or vice versa. It operates on 230
AC supply and is to be used with Minilec make
interconnecting cables for Minilec annunciators & for PC.

d) Electronic / Industrial Hooter

ACCEPT (FIRST-OUT RESET)

ACCEPT (FIRST-OUT RESET)

RS 232 / 485 Convertor

SILENCE / MUTE

A SILENT
Note:
P : Process Status, V : Visual Alarm Status, A : Audible Alarm Status, RB : Ringback audible alarm status.

Electronic Hooters with tone & volume control are supplied. Suitable for
AC or DC supply Standard 96 x 96 enclosure.

55

PROTOCOM-1
Twin AC Controller

Protocom 1 is useful for two AC installations in small offices /


businesses, ATM centers, residential houses, for AC units of 1 or
1.5 Tons. In Logic One Only one AC is operated at a time and equal
running of each AC is ensured during continuous operation. In
Second logic, One or both ACs will run as per Demand Built-in
protection against UV, OV & OL for both AC units.

PROTOCOM - 1 saves energy by alternatively using only one air conditioner (or both in case of temp rise) and
that too only when it is required depending upon logic selected. Two Types of different operational logics can be
selected with Protocom-1 through front Keys and display. These LOGICS are as follows.
During Logic # 1 operation : only one AC at a time will run for set time cycle in alternate mode. Changeover will
take place only if a) Cycle time is completed; b) Running AC is tripped due to Overload; c) Over Temp condition is
present for more that 10 minutes.
If the room temperature keeps on rising even with the AC unit is in operation, it will energize OT alarm relay. It will
stop funning AC, ALARM LED will glow and switchover to another AC unit overriding present timing. Thus it also
monitors and maintains the room temp.
During Logic # 2 operation : one AC will be running as normal running AC for set time cycle. If temp rises above
OT set point. second AC is switched on as stand-by running AC. This AC will be running until temp drops below
OT-Hystersis level (LIFO). In case, both AC are running and cycle time completes, none of the AC will be
switched off or no change over will take place. However if temp drops below. OT-Hystersis set point, first started
AC will be made off and running AC will be considered as normal running AC (FIFO).
FUNCTIONING
NORMAL CYCLIC OPERATION - After power ON POWER LED indication glows steady. Display will start
showing input AC voltage, AC1 & AC2 current and Room temp with scanning time of 5 sec. AC1will become ON
and will remain ON for next set time cycle. After completion of timing cycle, it will be OFF and second AC will ON.
Second AC will remain ON for next set time cycle. This operation will be repeated in cyclic mode. When AC is on,
respective LED glows steady. Internal timer will retain timing cycle (with resolution of 1 Hr. ) in case of power
failure with built in memory retention facility. Every time any AC will be made ON after ON delay of 2 Minutes.
UNDER VOLT AGE & OVER VOLTAGE : The PROTOCOM-1 offers built-in protection against under voltage (170
VAC with auto reset gap of 6 VA C) & over voltage (270 VA C with 6 VA C auto reset gap) with 4 sec. trip time
delay. Upon a rising one of above condition running AC will switched OF & 'ALARM' indication turns ON. Display
shows 'uV' / 'oV' indication. Once condition gets cleared, same AC will be made ON.
OVER LOAD - The PROTOCOM-1 protects the AC against over load condition of the set value. Running AC will
switch OFF after O/L trip time delay. 'ALARM' LED will glow, display will show 'oL' indication & Alternative AC
will be switched ON. Alternate AC will operate for remained time cycle & then again earlier AC will be switched
ON.
OVER TEMP. - The PROTOCOM-1 unit operates the AC by sensing the room temperature with the help of built-in
temperature sensor. After power ON or during running of any AC, the ambient temp is monitored and if it is above
set OT level for more than 10 minutes, then 'ALARM' LED turns on, also OT ALARM relay gets energized. If
PROTOCOM - 1 then running AC is switched OFF assuming that it is unable to lower the room temp below the set
level. Alternative AC will switch ON. It will operate for remaining time cycle. After completion of time cycle other
AC will be switched ON. 'OT ALARM' relay remain in energized condition till the ambient temp reduces below the
hystersis level of OT set point. In case LOGIC - 2 is selected, another AC will be made ON as stand by running AC.
FAULT BUZZER - After arriving of above any of fault condition Fault buzzer will be ON & will be retain for 1 Minute
or till clearance of fault Condition (except OL fault) whichever is earlier.

System supply
Frequency
Output Relay Contact
Output Contact Rating

240 V AC, 20%, 1 Ph


50 (60) Hz, 3%
1 NO + 1 NO + 1 NO
30 Amp @ 240 V AC (RLY 1 & RLY 2)
5 Amp (for RLY 3)

Current Setting
Power ON Delay
Cyclic time Delay
LED Indication
Power On
Alarm
AC 1 On
AC 2 On

8-16 Amp (Variable)


2 mins., 0.5 min (Fixed)
1 To 12 hours.
Green
Red
Green
Green

Enclosure

Sheet metal fabricated and powder coated

Dimension (approx.)
Overall (LxWxD)
Mounting (L x W)
Weight

141 x 193.9 x 72
117 x 169.5
1000 gms.

Trip settings, time delay and resetings


Parameters
Under Voltage
Over Volt Age
Over Load
Over Temperature
Trip Setting 170 3 VAC (Fixed) 270 3VAC (Fixed) 8-16 AMP (Settable by 20-400 C (Settable by
Keys & Display
Keys & Display
(Default Set - 12 A)
(Default Set - 300 A)
Hystersis for
6 VAC 3 VAC
6 VAC 3 VAC
N. A.
1 0 C - 50 C
Auto Reset
(Default - 30 C)
Trip Time Delay 4 SEC. 0.5 SEC. 4 SEC 0.5SEC. For 120% : 30 SEC10SEC
10 Minutes
For 600% : 2SEC 0.5SEC
Message on
uV
oV
OL1 - For AC 1
Ot
Display
OL2 - For AC 2
Logic Setting

Logic # 1
Logic # 2

Single ac operation only in alternate mode. [default set]


single or both ac operation based on temp. Rise in alternate mode.
auto reset type built in buzzer for uV, oV, ol & Ot trip
60sec. 5 Sec
3 Nos of Front Keys

Fault Buzzer
Alarm time
Setting Keys

UV

Aux
Supply

OV

O/L

600 %

AC
Current 300 %
(%) 120 %
100 %
0%

OT

SET OT

AMB. TEMP.
(C)

Td1
AC1 RLY
(C - NO)
AC2 RLY
(C - NO)
ALARM RLY
(C - NO)

56

T ON

Td2

T ON

T ON

T ON
T ON

Td1

T ON

Td2

Td3

Td3
T ON

Td4

Td4

Td4

Td4

Td4

T ON

Td4

BUZZER

LOGIC 1

LOGIC 2

T ON (on delay) - 2 min.


Td1 (overload delay) - As per IDMTL char.
Td2 (over temp. delay) - 10 min. Td3 (uv/ov trip delay) - 4 sec.
Td4 (buzzer) - 60 sec.

CYCLE END

SOFT STARTERS
Three phase asynchronous motors are used in industry due to its simple construction and
low maintenance operation. However, torque and motor current during the starting of a
three-phase asynchronous squirrel-cage motor is usually not very favorable.
Therefore electronic controllers, like EMS 2000, are used to reduce the high from
excessively high starting currents. By limited the accelerating torque, mechanical stress
on the material to be conveyed or processed, and consequently on all mechanical parts of
drive and driven machine, is reduced.
By starting motor at low voltage and avoiding large current peaks during starting with
current limit feature the cost of electricity may also be reduced.

MODELS :

FEATURES

D3 EMS1
EMS2000,
EMS-MMI

Suitable for Motors up to 5 HP and


10 to 75 HP
Soft Start and Soft Stop
Current Control
Various Starting options
MMI Functions with PC
communication
Equipped with important motor
protection functions

Ordering Instructions

Product Family Name


Model Name
System Name
System Supply Voltage
Aux. Supply / Control supply voltage
Motor rating (HP / KW)
Motor applications

57

S O F T S T A R T E R S
EMS 2000

Minilec introduces a new range of


Electronic Motor Starter - EMS-2000.
These newly introduced Electronic
Soft Starter are packed with unique
features and are designed for a standalone applications.

Protections
Eletronic over load protection - Adjustable range : 40% - 100%
( 100% = 5A, i.e. secondary of external CT )
Under voltage (-20% 1% of system supply)
SCR short/open fault protection ( Trip delay less then 100
microsec. )
Single phase protection ( Trip delay less then 5 microsec. )
Reverse phase protection ( Trip delay less then 5 microsec. )
Locked Rotor (for current above 500% to trip within 5 Sec.
Heat - sink over temperature (750 C 50 C)
HRC fuse with suitable ratings.

Up to 55 KW / 75 HP
90 Amp. (Max)
In-Built
415V AC (-20% + 15%)
50 Hz 3%
External Contactor
Normal High Volt Start
Normal Low Volt Start
Kick Low Volt Short duration start
Kick High Volt Short duration start
Kick Low Volt long duration start
Kick High volt long duration start
Range 150% to 350% of In (POT)
1 to 60 in steps of 1 sec.

Power Range (KW / HP)


Nominal Current (Amp)
Aux. Supply Voltage
System Supply
Line Frequency
Bypass facility
Start Mode

Current Limit % In (FLA)


Ramp Up Time (Sec.)
Ramp Down Time (Sec.)
Protections

Controls (External / Remote)


Start
Stop (soft stop also valid in by- pass made)
Emergency stop / system reset (free run to stop)

Twice of start time


Single Phase, Reverse Phase
SCR Short / Open, Unit overheat
Overload (IDMTL) Class 10/20
Under Voltage, Over Voltage
Lock Rotor 5 * IL < 5ms
0 to 45 Deg.C
220 x 210 x 170 mm.
10-20 HP - 10 Kg, 30-40 HP - 12 Kg.
50-60 HP - 14 Kg, 75 HP - 16 Kg.
N.A.
N.A.

Operating Temp.
Device Dimensions
Weight in Kgs (Approx.)
Communication
Protocol

Features
Soft Start - Adjustable soft start time
range : 1 - 60 sec.
Soft Stop - Twice of start time
Normal high volt start.
Kick start
Adjustable kick duration 400/800 ms.
Current limit
Adjustable range : 150% - 350% of FLA
(100% = 5A, of secondary of external CT)
Energy save ( PFC )
By pass

Relay output
Mains relay
By pass relay
Trip relay
Faults and Indications
To understand the fault indications refer following table.

Indication
Flashing
Flashing
Flashing

Under voltage / overload


Single phase / SCR fault
Single phase / SCR fault
Single phase / SCR fault
Trip relay ON

Steady ON
Flashing
Flashing
Steady ON
Steady ON

Typical equipment used with the EMS 2000 are :


Fans
Blowers
Compressors
Centrifugal pumps
Conveyoar belts
Cranes

Long Duration Kick With High Volt Start


voltage

voltage

0.8 sec.

100%

100%

100% - - - - - - - -

90%

50%

50%

40%

0%

time

0%

time

0%

time

100
10

ON

MOTOR

LOCK ROTOR
curve

8
6

2
1
50
40

SECONDS

Emergency
STOP / Reset

IDMTL
O/L curve

TIME

EMS 2000

MINUTES

MAINS
Contactor

OLR

58

Led
Under voltage / overload
Under voltage / overload
Under voltage / overload

Typical fields of application for "EMS 2000" include.


Electrical drives for processing materials which are sensitive
to jerking and pulling.
Pump drives.
Drives with long periods of operation under no-load condition.
Machines with transmission systems, belt or chain drives.
Drives with large moments of inertia.

Normal low Volt Start (without Kick)

Normal High Volt Start (without Kick)

voltage

R
Y
B

Bypass
Contactor

Fault
Overload
Lock rotor
Heat sink over
Temperature
Under voltage
SCR short
SCR open
Single phase
Reverse phase

30
20
10
8
6
4
2
1
5 msec
0

S O F T S T A R T E R S
EMS-MMI

This is an advanced version of


EMS 2000 with features like
display, protections and
communications

Power Range (KW / HP)


Nominal Current (Amp)
Aux. Supply Voltage
System Supply
Line Frequency
Bypass facility
Start Mode

Current Limit % In (FLA)


Ramp Up Time (Sec.)
Ramp Down Time (Sec.)
Protections

7.5 KW / 10 HP
16 Amp.
90 270V AC / DC
415V AC (-20% + 15%)
50 Hz 3%
External Contactor
Normal High Volt Start
Normal Low Volt Start
Kick Low Volt Short duration start
Kick High Volt Short duration start
Kick Low Volt long duration start
Kick High volt long duration start
Range 150% to 350% of In Selectablely (Digital)
1, 5, 10,15, 20, 30, 45, 60 Selectablely (DIP Switch)

Twice of start time

Operating Temp.
Device Dimensions
Weight in Kgs (Approx.)

Single Phase, Reverse Phase


SCR Short / Open, Unit overheat
Overload (IDMTL) Class 2 (Pot),50% to 100% of FLA
Under Voltage
Lock Rotor 5 * IL < 5ms
0 to 45 Deg.C
220 x 210 x 170 mm.
10 Kg.

Communication
Protocol

RS 232 & RS 485


ASCII & RTU

Long Duration Kick With Low Volt Start

Short Duration Kick With High Volt Start

Short Duration Kick With Low Volt Start

voltage

voltage

0.8 sec

v oltage
0.4 sec

0.4 sec

100%

100%
90%

100%
90%

90%

50%

40%

40%

0%

time

0%

time

0%

time

R
Y
B

MAINS
SUPPLY

F1
TO CONTROL
SUPPLY

K1
OL
F2

ON
OFF
To
PTC
of Motor
Aux
Supply

RS 232

EXTERNAL
CT

Aux
Supply
1

R Y

F5

2 3

1 2

MOV
UNIT

DEVICE 2

RS 232

3 4 5 6

DEVICE N

DB 9

COM
RESET

13 14 15

SOFT STOP
SOFT START

MAINS ON
BY PASS
TO CONTROL
SUPPLY

ALARM

1
2
3
4
1

N = 32

RS 485
RJ 45
TO CONTROL
SUPPLY

EMS MMI

2
3
4

DEVICE 1

DEVICE 3

F4

K2

5
6

Earth

U V

HOOTER

To WTR

Motor
Earth

Fig. 7.2 External wirin g diagram

59

S O F T S T A R T E R S
D3 EMS1

This is a Small size soft starter


with DIN-Rail mounting feature
idealy suitable for light duty
small motor applications

Power Range (KW / HP)


Nominal Current (Amp)
Aux. Supply Voltage
System Supply
Line Frequency
Bypass facility
Start Mode

1.5 KW / 2 HP, 2.2 KW / 3 HP, 3.7 KW / 5 HP


8 Amps. Max.
24-110V AC/DC (+15% - 20%) 110-415V AC (+15% - 20%)

415V AC + 15% - 20%


50/60 Hz
Built-in (Via Internal Contactor Relay)
Reduced Volt Start

Current Limit % In (FLA)


Ramp Up Time (Sec.)
Ramp Down Time (Sec.)
Protections

N.A.
Adjustable from 0.5 to 10 Sec.(25%)
Adjustable from 0.5 to 10 Sec.(25%)
N.A.

Operating Temp.
Device Dimensions
Weight in Kgs (Approx.)

- 5 C to 45 C
Overall (L x W x D) 76 x 82 x 115
340 gms (approx.)

Communication
Protocol

N.A.
N.A.

MOTOR
VOLTAGE
(TORQUE)
RAMP-DOWN

RAMP-UP
100%
Initial Torque
up to 80 %
of nominal
torque

With this soft starter 3-phase motors with nominal load currents upto 8 A can be soft-started
and / or soft-stopped,thus reducing the inrush current and eliminating the damaging effects of high starting
current surges. This is a compact star ting device for small motors and hence
there is room for more products on a given mounting platform. Itis easy to install and to adjust
because access for connections and adjustments is from the front. The device is snapped on
to a DIN mountin grail. Star ting and stopping time as well as initial torque can be
independently adjusted by built-in potentiometers.
FEATURES
1) Reduced current in rush and mechanical shock
2) Soft, smooth, step-less acceleration & deceleration
3) Soft Start Time, Soft Stop Time, Initial Torque independently settable by means of potentiometer
4) Built-in by passrelay (For by passing SCR)
5) Easy to install and operate
6) Millions of switching cycles
7) Compact, lightweight
8) DIN-rail mounting (35mm)
9) LED indications for 3-ph ON, Ramp up / Ramp down and Run
CONTROL AND SETTINGS
D3EMS 1 has three potentiometers control on its front.
1) Ramp up :
To set ramp up time ( 0.5 to 10 Sec. )
2) Ramp down : To set ramp down time ( 0.5 to 10 Sec. )
3) Initial torque : To set initial torque of the motor ( 0 to 80% )
Set Ramp - up time and Initial Torque such that motor will start without jerk and humming noise.
FUNCTIONAL DESCRIPTION
Soft Start : During ramp-up, the soft starter will gradually increase the voltage to the motor until it reaches full
line voltage. The motor speed will depend on the actua lload on the motor shaft.
Initial Torque : The initial torque is used to set starting voltage. This way it is possible to adapt the soft starter
to an application requiring a higher starting torque. It can be adjusted from 0 to 80% of nominal torque.
Softstop : During ramp-down, the will soft starter gradually reduce the voltage to the motor thus reducing the
torque and current. The soft stop feature is advantageous to avoid water hammering and caviation on pumps
and to avoid goods tilting on conveyors. It is typically used on motor application where a smooth startand / or
stop is advantageous there by reduce the wear on gear and belt / chain drives. It is used for light duty
applications such as small conveyors, bottle washers, pump-bore, slicer etc.
PROTECTION
This unit does not provide any protection.Hence user has to take care of necessary protections.

TIME
0.5-10 SEC

0.5-10 SEC

24 - 110V

CONTROL
SUPPLY

START

STOP

3-PH ON
GREEN LED

TEST(R-up)

TEST(R-dn)

18
17
16

110 - 415V

RU/RD
RED LED
RUN
YELLOW
LED

1sec

1sec

INITIAL TORQUE
( 0 - 80%)
(80%)

60

8
L1 L2 L3

SYSTEM
SUPPLY

RUN

(50%)
(0%)

Ru
(0.5-10sec)

Rd
(0.5-10sec)

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

PRODUCTS FOR AGRI SECTOR


Minilec offers a range of products for protection
of water pumps used by farmers. These are
primarily to monitor incoming 3-phase supply
for Single Phasing, Reverse Phasing and
unbalanced supply and stop the pump in case of
any fault. Additional features in some models
include low water level monitoring (for
borewell pumps) and auto restarting.
The products are specifically produced for
marketing and use in India only.

MODELS

VSP2, VSP3, VPGD1


Autoswitch-2, Autoswitch-4
Autoswitch-5, Autoswitch-6

FEATURES

PROTECTIONS / FUNCTIONS

Monitor incoming 3-phase supply


Models with pre-wired
connections
Easy to fit inside most motor
starters
Switch for Auto-Manual
operations
Switch provision either built-in or
external
Adjustable on time delay
All protections in auto & manual
modes
Built-in timer for star-delta
operation
Low level monitoring of borewell
pumps

Single Phasing,
Reverse Phasing,
Unbalanced supply (dry running)
low water level
On Delay to avoid immediate
re-starting of pumps during
auto mode

61

P R O D U C T S F O R A G R I S E C T O R
VSP2

VSP3

VPGD1

Smallest size of single


phasing preventor
Single phasing, reverse
phasing, unbalanced supply
Auto reset, 1 NO output
contact Suitable for any
HP/kW rating moboblock
pumps

Single phasing, reverse phasing,


unbalanced supply
Auto reset, 1 NO output contact
Suitable for any HP/kW rating
moboblock pumps
Pre-wired terminals for easy
connections

Single phasing, reverse phasing,


unbalanced supply
Auto reset, 1 CO output contact
Suitable for any HP/kW rating
submersible pumps
Low water level guard for dry
running protection

Supply Voltage
Output Relay Contact
Output Contact Rating
Unbalance Trip Setting

415 VAC 20%, 50 Hz 3%


1 NO
5 Amp, 240 VAC (RESISTIVE)
40 V 6 V

415V AC 20%, 50 Hz 3%
1 NO
5 Amp, 240 VAC (RESISTIVE)
50 V 10 VAC

415VAC 20%, 50 Hz 3%
1 CO
5 Amp, 240 VAC (RESISTIVE)
40V 6V

Trip Time Delay


For unbalance
For level sensing
On Time Delay

3.5 sec. 1.5 sec.


N.A.
N.A.

3.5 sec. 1.5 sec.


N.A.
N.A.

3.5 Sec 1.5 Sec


3.5 Sec 1.5 Sec
N.A.

Star-Delta Changeover Time Delay


Resetting

N.A.
Auto Reset

N.A.
Auto Reset

N.A.
Auto Reset

Auto Switch
Enclosure
Dimensions (mm)
Overal ( H x N x D )
Mounting
Mounting
Weight
Level sensor
Quantity
Dimensions
Operating Conditions
Temperature
Humidity

N. A.
HIP moulded, with Nylon connector strip

N. A.
HIP moulded

N. A.
ABS

103 x 66 x 43
91 x 48
Panel Mounting
260gms

103 x 66 x 43
91 x 48
Panel Mounting
250gms

76 x 30.5 x 117.5
68 [center to center]
Panel Mounting & 35mm Rail Mounting
300gms

1 NO. SS
24 [dia.] X 76 [L] 50

-5 C TO + 60 C
Upto 95% Rh

-5 C TO + 60 C
Upto 95% Rh

-5 C TO + 60 C
Upto 95% Rh

L1

L2

R Y B

X X X X X X

R Y B

Remove this link

L3

X X X X X X

Remove this link

N/V
X

X
X

X
X

X
X
X

OFF

X
X

RED
YELOW
BLUE

GRAY
GRAY

X
X

ON

RED
YELOW
BLUE

1 2 3
VPG D1

GRAY
GRAY

PROD

7 8 9

13 14 15
WATER TANK

62

PUMP
MOTOR

P R O D U C T S F O R A G R I S E C T O R
Auto switch - 4

Auto switch - 5

Single phasing, reverse


phasing, unbalanced supply
Auto reset, 1 NO output contact
On time delay upto 1 Minute
(fixed) Auto-Manual switch
built-in. Suitable for any
HP/kW rating pumps. Prewired terminals for easy
connections

Single phasing, reverse


phasing, unbalanced supply
Auto reset, 1 NO output contact
On time delay 1 to 10 Minutes
(Adjustable)
Auto-Manual switch built-in on
front. Suitable for any HP/kW
rating pumps. Pre-wired
terminals for easy connections

Single phasing, reverse phasing,


unbalanced supply
Auto reset, 1 NO output contact,
On time delay 1 to 10 Minutes
(Adjustable), Provision for
connecting Auto-Manual switch
externally, Suitable for any
HP/kW rating pumps, Pre-wired
terminals for easy connections

Single phasing, reverse phasing,


unbalanced supply
Auto reset, 1 NO output contact,
On time delay 2 to 3 Minutes (fixed),
Star Delta Changeover Timer, AutoManual switch built-in on front,
Suitable for any HP/kW rating
pumps, Pre-wired terminals for
easy connections

Auto switch - 2

Auto switch - 6

415 VAC 20%, 50 Hz 3%

415 VAC.( 20%), 50 Hz 3%

200 - 450 VAC, 50 Hz 3%

415VAC 20%, 50 Hz 3%

1 NO
5 Amp, 240 VAC (RESISTIVE)
50 V 10 VAC

1 NO
5 Amp, 240 VAC (RESISTIVE)
50 V 10 VAC

1 NO
5 Amp, 240 VAC (RESISTIVE)
50 V 10 VAC

1 NO + 1 NO
5 Amp, 240 VAC (RESISTIVE)
50V 10V

4 Sec 2 Sec
N.A.
45 Sec 15 Sec

4 sec 2 sec
N.A.
1 to 10 min

4 Sec 2 Sec
N.A.
1 to 10 min

3.5 Sec 1.5 Sec


N.A.
2 to 3 minutes [In auto mode]

N.A.
Auto Reset

N.A.
Auto Reset

5 to 7 Sec.
Auto Reset

Present
Housing: HIP / Mounting Clamp: Nylon 6

Present
Housing: HIP / Mounting Clamp: Nylon 6

N.A.
Auto Reset
To be connected externally

102 x 35 x 81
90 mm Centre to Centre
Panel Mounting
300gms

102 X 35 X 81 mm
90 mm Centre to Centre
Panel Mounting
300gms

Housing: HIP / Mounting Clamp: Nylon 6

Present
Housing: HIP / Mounting Clamp: Nylon 6

102 X 35 X 81 mm
90 mm Centre to Centre
Panel Mounting
300gms

102 x 35 x 81
90 mm Centre to Centre
Panel Mounting
300gms (Approx.)

-5 C TO + 60 C
Upto 95% Rh

-5 C TO + 60 C
Upto 95% Rh

-5 C TO + 60 C
Upto 95% Rh

Remove this link

SINGLE PHASING PREVENTER


SELECTABLE ON DELAY TIMER (1 - 10 MIN)
EXTERNAL AUTO / MANUAL SWITCH

RED
YELOW
BLUE

EXT. DPDT
SWITCH

STOP

START

BLUE

X X X X X X

YELLOW

Y B

-5 C TO + 60 C
Upto 95% Rh

R ED

GREEN

GREEN

X
AUTO

GREEN
GREEN

MAN

N/V COIL

GRAY

X
X

GRAY

M
X

GRAY

GRAY

X
X

X X

REMOVE THIS LINK

X X X X X X

X
R

Y
Y

RED

RED

YELLOW
BLUE

YELOW
BLUE
R

Remove this link

GRAY
P1

GRAY

OFF

X
X

SHORT LINK

GREEN
ON

A1

YNO

B1

C1

C2 A2 B2

MNO

X
X

GREEN

YNC

GRAY
NC

GRAY

P2
GREEN
GREEN

63

Pune - The City of Minilec


Pune has the sixth largest metropolitan economy and the highest per capita
income in India, with the least income disparity between the rich and poor. This
city is often addressed with the twin title of 'Oxford of the east' and 'Detroit of
India'. Besides being a cultural capital of Western India, Pune is also an
industrial and IT hub
Pune is well connected by road, rail, and air to all major cities in India. Pune has
an international airport, two important railway junctions and three major state
and inter-state bus junctions. Pune has a light rail/ skybus /light metro rail
proposal for implementation

ICC Towers - International convention Center

The Pirangoot Industrial estate is located to the west of the city of Pune. It is a
clean and green area blessed with picturesque mountains. Minilec is located in
the heart of green Pirangoot, about 15 Km. from Pune

Pune University

Associate companies
The Intech Group
Statfield Equipments Pvt. Ltd.:
Pioneers in India in surface finishing equipments.
Intech Surface Coating Pvt. Ltd:
Involved in industrial paint-shop technology and products.
Intech Auto-Stores and Conveyors Pvt. Ltd:
Industrial products for material-flow management.
The Mint Group
Mint Biofuels Pvt. Ltd.:
Manufacturers of biodiesel and its bio-products

Mumbai
Pune

Yashaprabha Agro Pvt. Ltd.:


Cultivation & management of biofuel plantations.
Intech Energy Pvt. Ltd.:
Manufacture and erection of biofuel plants and machinery
Suyash Charitable Trust:
Working for social and financial upliftment of tribals in India.

Minilec (India) Pvt. Ltd.

Cat. No. GC 083 / R1

Factory & Head Office :


S. No. 1073/1-2-3, At Post : Pirangoot - 412 111.
Tal - Mulshi, Dist. Pune (India)
Tel. : (020) 22922162 / 22922354 -57 Fax : ( 020) 22922134
E-mail : mkt1@minilecgroup.com

Authorised Dealer

Branch Offices :
Mumbai:
Delhi :
Bangalore :
Kolkata :

Tel. : 2596 51 41
Tel. : 2489 47 32
Tel. : 2486 74 18
Tel. : 2485 14 18

E-mail : mumbai@minilecgroup.com
E-mail : delhi@minilecgroup.com
E-mail : bangalore@minilecgroup.com
E-mail : kolkata@minilecgroup.com

Customer Support: E-mail : servicing@minilecgroup.com

www.minilecgroup.com

Potrebbero piacerti anche