Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
SM
Dropped Objects
The Halliburton 10 to Zero Life Rules are a compilation of basic rules
that all Halliburton employees know and live by. These are key components
CoilComm Services
SM
Content:
Real -Time Service
System Components
Distributed Temperature Sensing (DTS)
CoilComm Services
SM
CoilComm Services
SM
CoilComm Services
SM
CoilComm Services
SM
O.D
2.125
2.25
3.375
I.D.
0.65
0.65
1.25
Length
11ft
11ft
14ft
5/8
5/8
Pressure Rating
10,000 psi
15,000 psi
15,000psi
Temperature Rating
350 F
350 F
350 F
2 BPM
2 BPM
7 BPM
0.9 BPM
0.9 BPM
3 BPM
CoilComm Services
SM
Acquisition Software:
IWI user friendly software for best data visualization and handling
Depth co-relation interface window
One single Software Program to support the whole job
Facilitate immediate monitoring by CT operator
Real time availability of Acquisition data in Client Offices worldwide
CoilComm Services
SM
Hot/Cold slugs
Gas entry points
Cross- flows
CoilComm Services
SM
10
11
12
Holley et al;
SPE 136565
Tool Description
Coiled Tubing
Downhole Tool
Fiber Cable
CCL
Pressure Gauge
Temp Gauge
CT Unit with FO
Cable
13
v
v
12 Previous Stimulations
Fluid Placement Uncertainty
417 m
vv
14
Xylene injection
5200
5400
5600
Depth (m)
5800
6000
6200
6400
6600
130
135
140
145
150
Temperature (C)
155
160
Temp
Slurry Rate
Treating Pressure
Temperature profiles almost parallel to base temperature, most treatment fluids went through
the lower perforations.
2014 HALLIBURTON. ALL RIGHTS RESERVED.
15
Perforation
Cleanup with
Coiled Tubing
5200
After
Cleanup
5400
5600
NO DATA WAS
RECORDED,
COILED TUBING
WAS BEING
MOVED
Depth (m)
5800
6000
6200
6400
6600
140
145
150
Temperature (C)
155
160
Temp
Slurry Rate
Cooling effect observed due to the stimulation, but TEMPERATURE below punchers (5,380m)
is HIGHER after perforation cleansing with coiled tubing, indicating an INCREASE in general
PRODUCTION.
2014 HALLIBURTON. ALL RIGHTS RESERVED.
16
5200
2:46 2:50
6:36
7:23
5400
5600
Depth (m)
5800
6000
6200
Temp
6400
Slurry Rate
6600
115
17
120
125
130
135
140
145
Temperature (C)
150
155
160
Bricol Summary
Fiber Optic Cable inside
Coiled Tubing
Degradable Divergent
Particles
THE GAIN
78% Increase in Production Post-Stimulation
Roughly 4 TIMES improved production compared to
previous stimulation methods.
18
CoilComm Services
SM
Type of Services:
Perforation Cleanouts
Packer Setting
Nitrogen Kick-off
Milling
Abrasive pumping
Perforating
19
Q & A Session
20