Sei sulla pagina 1di 2

CAN Remote Control System

CATTRONCONTROL

TM

ROAD H EA D E R
High safety class through redundant
hardware and software structure
Approvals and frequencies for
worldwide deployment
Application specific layout
Housing made of high-impactresistant polycarbonate resin
A variety of Operator Control
Units can by used

The CAN Remote Control System (CAN RCS) for Road Headers sets
new standards for the industry. This CAN RCS greatly simplifies the
installation of a remote control on any CANRoad Header. When connected to the CAN
network of the Road Headers main computer,
the CCM12 Receiver acts as a wireless gateway between the vehicle and the Operator
Control Unit (OCU). All functions executed on the OCU are transferred on the
CAN Network and the Road Headers vital signs are sent back to the OCU.

CAN REMOTE CONTROL SYSTEM TECHNICAL DATA AND SPECIFICATIONS

CAN Remote Control System


CATTRONCONTROL

TM

Dual CANbus interfaces that meet


ISO 11898-2 standard
Dual safety relay outputs
Both CAN interfaces are electrically isolated
Dual Processor Redundant Architecture for Safety
Unique ID key for the utmost safety of personnel
and property

TECHNICAL DATA AND SPECIFICATIONS


Power Supply Characteristics

RF
Frequency ranges:

Transmission speed:
Transmitter output power:
Receiver sensitivity:

335 MHz
418-419 MHz
433-434 MHz
447 MHz
410-470 MHz
868-869 MHz
903-927 MHz
4.8 20 Kbit/s
410-470 MHz: up to 500mW
All others: <10 mW
-107 dBm

Input voltage:
Input current:
Protection:

6-32 VDC
Less than 175 mA at 24 VDC
Reverse polarity
Load dumps
Electrical transients

Norms and Standards


IP protection class: IP 66
Safety standards:
EN 954-1 category 3 for all
safety related functions
EN 13849-1 Performance Level d

CAN Interface Characteristics

Electronics
Digital circuitry:
Dual-processor technology
System addresses:
24 Bit =16 million addresses
Security relay type:
EN 50205, type A
Safety relay switching current: 4 A, fused
Shock resistance 16msec:
17 g

CAN format:
Bus speed:
Standard:
Protection:

CAN 2.0A and CAN 2.0B


10, 20, 50, 125, 250, 500, 1000 kbps
ISO 11898-2
Exceeds ISO 11898-2
Bus fault protection ( -27 to +40 V)
Transient voltage
(-200 to +200 V)

Mechanical Data
Dimensions:
Operating temperature:

122 x 144 x 48 mm (L X W X H)
-20 to + 60 C

All data provided here serves merely to describe the product and should not be interpreted
as implying warranted features or characteristics within the legal meaning of these terms.

TM

Cattron-Theimeg Canada Ltd. (Georgetown, ON)


ISO 9001:2000 Registered Tel: (+1) 905-873-9440 salescdn@cattrongroup.com

GROUP INTERNATIONAL

www.cattrongroup.com

Cattron-Theimeg Canada Ltd. (Saint-Laurent, Quebec, Canada)


Tel: (+1) 514- 908-1659 mail@cattrongroup.com
Cattron-Theimeg UK Ltd. (Walton-on-Thames, UK)
BSEN/9001:2000 Registered Tel: (44) 1932-247 511 sales@cattronuk.com

Cattron Group International World Headquarters ( Sharpsville, PA, USA)


ISO 9001: 2000 Registered Tel: (+1) 724-962-3571 mail@cattrongroup.com

Cattron-Theimeg Americas Ltda. (Sao Paulo, Brazil)


Tel: (55) 19-3243-7803 vendas@cattron.com.br

Cattron Group International (Escondido, CA)


Tel: (+1) 760-737-7800 mail@cattrongroup.com

Cattron-Theimeg Europe GmbH & Co. (Mnchengladbach,Germany)


ISO 9001:2000 Registered Tel: (49) 2161 6363-0 info@theimeg.de

Cattron Group International Asia-Pacific (Shanghai, China)


Tel: 86/21/2308/1128 saleschina@cattrongroup.com

Cattron-Theimeg Africa (PTY) Ltd. (Johannesburg, South Africa)


Tel: (27) 11-425-1123 cattron@cattronsa.com