Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
209
JR - 4 bolt
A = 2-1/32
SR - 4 bolt
1-1/4 Thread
A = 2-1/2
1 Thread
Distance
"H" Dimension
"H"
"H" Dimension
"H"
Height
Footring
Center
Line
End
Mount
Top Mount
Angle Mount
Side Mount
End Mount
Side Mount
Note: Pivot point of float must be at center line of tank.
210
Application
0049S02159
12 12 to 19 34
Above Ground
Application
0049S02207
12 12 to 19 34
Above Ground
Application
0049S02203
12 12 to 19 34
Above Ground
Application
0049S02160
12 14 to 19 34
Above Ground
Tank Diameter
6857S11009
6857S13759
6810S14379
6857S17009
24
30
32
37.5
Assembly Instructions
B6287-4
STEP 1: **NOTE: THESE ASSEMBLY INSTRUCTIONS ARE GOOD FOR MODEL #'S 6285-, 6287, 7287-, & 8987OLD GAUGE LENGTH
STEP 4:
STEP 5:
GEAR HOUSING
LOCKNUT
B6287-4
CENTERSHAFT
"R" LOGO
MARK OR SCRIBE
CENTERSHAFT AS SHOWN
STEP 2:
ORIGINAL MARK
FROM STEP 1
AT
STEP 7:
.
C
C
Y
YL
L.
80
HES
C HES
RO
ROC
FILL
FILL
TER
GAU
GAU
30
GES
GES
INC.
INC.
OF
OF
90
95
ING
ING
20
TEX
TEX
AS
AS
UL
10
U.S.A.
DAL
DAL LAS
TX. U.S.A.
LAS TX.
NO.
NO.
DIAL
DIAL
B6287-4
H R
IZ
Z ..
TA
AN
NK
ND T
UND
KS
S
ROOU
MAX.
MAX. LEVE
GR
LEVEL
%
%TTO
EG
L
OTT
VE
LIQUID
AT
AT LIQUID
O
OV
AALL
BB
PP.. F
TEM
TEM
F
AA
VV
20 60
60 80
00 20
80
100
BBUU
100
BBUU
120
120
RROORROO
0P
0P PP
00
70
60
50
40
55 /
55
O
O
CAREFULLY
RETIGHTEN
ORIGINAL MARK
LINES UP WITH
EDGE OF LOCKNUT
E
E
M
M
SHAFT IS NOW
RECESSED
U
LLU
O
O
B6287-4
33
STEP 3:
STEP 6:
27
5-
TO BE LOOSENED
211
Bolt circle*
Description
Mounting bolt
Top mounting
2 1/32
6284
(4) 1/4" - 28
*Measured diagonally
Description
Mounting Bolt
Top mounting
6283
(4) 5/16" - 24
6290
6293
*Measured diagonally
Description
7281
7284
Hex
2"
Description
Hex
8981
Top mount
2"
Part #*
Description
Hex
7381
Top mount
7384
End mount
2"
*Use B prefix for Brass head gauge, ie: B7384 Brass Head Gauge
212
NH3 Gauges
The A6200 series gauges are designed to withstand the corrosive rigors of NH3 service. The A6400 series is all-stainless-steel
construction designed to withstand NH3 with chemical additives. All A prefix gauges are UL listed for NH3 service. These
gauges come standard with direct-reading percentage dials.
Description
A6281
A6284
Description
A6280
A6283
Description
For top mounting,
N-Serve Gauge
Description
5323S01848
Junior
5002S00002
Senior
Description
0015-00855
Junior
0015-00836
Senior
213
Cylinder
Size
Mounting
Dial #
Universal
5343S01823
14 lb.
9" I.D.
Horizontal
5323S01789
Vertical
5323S01819
Universal
5343S01815
Horizontal
5323S01789
6284-32
6284-39
6281-5
6284-33
6284-24
20 lb.
12" I.D.
6281-45
Vertical
5323S01818
6284-34
Universal
5343S01791
Horizontal
5323S01789
6284-24
33 1/2 lb.
12" I.D.
6281-48
Vertical
5323S01820
6284-35
Universal
5343S01824
Horizontal
5323S01789
Vertical
5323S01821
Universal
5343S01791
6284-24
43 1/2 lb.
12" I.D.
6281-49
6284-46
6284-45
60 lb.
14" I.D.
Horizontal
5323S01789
6281-50
Vertical
5323S01817
6284-45
Horizontal
5323S01789
6281-38
Vertical
5323S01813
Vertical
5323S01814
Vertical
5323S01816
6281-39
100 lb.
14 1/2"
6281-47
Cylinder
Size
214
Mounting
Universal
Dial
5714S02591
Cylinder
Size
Mounting
Dial #
Universal
5343S01815
Horizontal
5323S01789
Vertical
5323S01818
7284-33
7284-24
20 lb.
12" I.D.
7281-45
7284-34
7284-24
33 1/2 lb.
12" I.D.
Universal
5343S01791
Horizontal
5323S01789
Vertical
5323S01820
7281-48
7284-35
7284-24
43 1/2 lb.
12" I.D.
Universal
5343S01824
Horizontal
5323S01789
Vertical
5323S01821
7281-49
Cylinder
Size
Mounting
Dial #
7381-1003
14 lb.
9" I.D.
Vertical
5323S01915
Universal
5343S01912
Horizontal
5323S01944
7384-1002
Vertical
5323S01914
7384-1006
Universal
5343S01992
7384-1005
7384-1008
7384-1008
7384-1007
7384-1008
7384-1010
20 lb.
12" I.D.
33 1/2 lb.
12" I.D.
43 1/2 lb.
12" I.D.
60 lb. or 100 lb.
14 1/2" I.D.
Horizontal
5343S01944
Universal
5343S01993
Horizontal
5343S01944
Horizontal
5323S01944
215
Tank
Mfg.
Rochester
Part #
Manchester
6244-00600 B**
H8LN
320
DR
Brunner
Brunner
Brunner
Manchester
6244-605
6244-00032
6244-00046
6244-00353
H8AB
H10AB
Lower 45
315
H10C
CENTER
DR
DR
DR
DR
Brunner
Brunner
Manchester
6244-00047
6244-00094
6244-00354
H12C
CENTER
Manchester
Brunner
Brunner
6244-00384
6244-00048
6244-00097
10
12
13
14
16
Brunner
6244-00054
Manchester
Manchester
6244-00334
6244-00599
Brunner
Brunner
Brunner
Brunner
Manchester
Brunner
Brunner
6244-00049
6244-00100
6244-00055
6244-00105
6244-00338
6244-00050
6244-00106
Manchester
18
20
Mounting
Angle
H13LN
320
H13C
CENTER
H14A
45
H14LN
320
H14C
CENTER
H16A
45
H16C
CENTER
6244-00604 B**
Brunner
6244-00056
Manchester
Brunner
Brunner
Manchester
Brunner
Manchester
Brunner
6244-00340
6244-00051
6244-00109
6244-00357
6244-00058
6244-00342
6244-00052
Manchester
6244-00358
Brunner
Dial
Type*
DR
TS
DR
DR
DR
TS
DR
DR
DR
DR
TS
DR
TS
DR
DR
TS
DR
DR
H18A
45
H18C
CENTER
H20A
45
H20C
CENTER
6244-00344
H22A
45
DR
Brunner
6244-00343
H22C
CENTER
DR
Brunner
6244-00074
Manchester
Brunner
6244-00181
6244-00073
H24A
45
Manchester
6244-00371
H24C
CENTER
Brunner
6244-00085
H30C
CENTER
22
24
Gauge Head
Stamp
30
DR
DR
TS
DR
DR
DR
DR
DR
DR
DR
DR
DR
DR
TS = Twinsite Sender
Part #
Description
Application
F7183
5001S00605
Stationary tanks.
Fractional dials
Vibration dampened for mobile tanks.
5002S00605
For correct float-rod sizing and installation, refer to the figure below.
2 Tank height minus 2"
216
Mounting
6336 -11
Top
Dial size
4"
6339 -11
Side, end or angle
6342 -11
8"
Top
6360 -11
Type
Service
Gauge
Flange
-11
LPG or NH3
Type 316
stainless steel
Type 303
stainless steel
Alnico VI
All
other
parts
300 series
stainless
steel
Mounting Prefix
X = When straddle mounting is required.
Y = When ordering gauge for 2" opening.
M = Special mobile.
V = Vertical tank.
Combination
LPG/NH3
6342
11
108"
Part #
C6342-11-84
Diameter Of Tank
84"
C6342-11-108
108"
C6342-11-130
130"
Straddle mounted
217
Transport Gauges
Ideal for LPG or NH3 bobtails and transports. Also available for CO2 use.
Magnetel Rough Rider Gauges
The Rough Rider is designed to withstand the vibration and
shock inherent in mobile service. Their service life in over-theroad and off-road transports carrying liquids including LP Gas,
NH3, and cryogenic liquids is unsurpassed. These gauges provide accurate indications of liquid level at a glance, making inconvenient rotary gauges obsolete.
Rough Rider gauges are equipped with an exclusive spring
steel shock absorber on the float arm which substantially reduces the stress that can quickly destroy conventional gauges.
C = Combination LPG/NH3.
D = Insulated extension for CO2 and other cryogenic liquids.
Mounting Prefix
M = Special mobile mounting.
Description
P6293-R7200
P6293-R8400
218
Diameter of tank
72"
CM6339-11-79
79"
4"
CM6339-11-84
84"
CM6339-11-96
96"
Dial
CM6339-11-72
Rotogage Dials
Part
Number
Service
A9091-18L
LP-Gas
All Sizes
A9091-18LX*
LP-Gas
A9091-18N
NH3
All sizes
Container Size
* Dial permits higher filling level, as per NFPA 58, (1983) Par. 4-5.2.1, Table 4-5.2.1
For Stationary
Containers
Only
A9091R
A9092R
Ellipsoidal Heads
Standard
Dip Tube
Part No.
A9091-M24.0
Side
Mounted
Standard
Dip Tube
Length
24"
36"
A9091-M36.0
A9093TS*
A9093RS
48"
A9094TS*
A9095TS*
A9094RS
A9095RS
60"
72"
Hemispherical Heads
End
Mounted
Side
Mounted
End
Mounted
30" - 45"
30" - 75"
30" - 45"
30" - 45"
46" - 61"
76" - 108"
46" - 61"
46" - 61"
A9091-M48.0
62" - 79"
109" - 147"
62" - 79"
62" - 79"
A9091-M60.0
A9091-M72.0
80" - 99"
100" - 147"
80" - 99"
100" - 147"
80" - 99"
100" - 147"
* Supported Design
NOTE: The dip tube must be cut to the required length (12" of container inside diameter minus 534").
Custom dip tube lengths available upon request.
Dip Tube
For Containers
with Inside
Diameter
2071-L25.7
Up to 40"
2071-L39.7
Up to 60"
Part Number
Rotogage
2070CO
Tank
Connection
34
" M. NPT
Valve
Seat
Orifice
No. 54
Drill Size
NOTE: The dip tube must be cut to the required length (12 of container inside diameter minus
12"), when mounted on center line of tank.
219
Description
Rochester Junior Dial / ASME Above ground
Rochester Junior Dial / ASME Under ground
Rochester Senior Dial / ASME Above ground
JY Taylor Style A Dial
JY Taylor Style B Dial
5909S02733
5986S02733
5987S02787
Description
Replaced by R3D Dial # 5909S02733
Junior Dial for LPG ASME Underground Tanks 5-95%
Junior Dial for NH3 ASME Underground Tanks 5-95%
5323S01813
Description
Junior Mobile Dial - Fractional
Junior Dial 10-82% for Vertical Cylinders
Junior Dial 5-88% for Vertical Cylinders
Junior Universal Dial 33.5# Cylinders
Junior Universal Dial 43# Cylinders
5323S01789
5323S01835
5323S01791
Description
Junior Universal Dial 33.5# Cylinders
Junior Universal Dial 43# Cylinders
5714S02591
Description
Junior Snap-On Dial for 8981 Series Gauges
Junior Snap-On Dial for 8944 Series Gauges
5364S01951
Description
Senior Dial for LPG - For Above ground use
Senior Dial for NH3 - For Above ground use
5844S01749
220
Part #
Description
3181-01749
3180-17001
3181-01848
Par t #
Description
Resistance
Range
Part #
Description
Resistance
Range
P5628S02537
JuniorTwinSiteSender
(for GM)
0-90
P5752S02599
JuniorTwinSiteSender
(For GM)
40-250
P5630S02538
JuniorTwinSiteSender
(for Ford & Chrysler)
70-10
P5827S02649
JuniorTwinSiteSender
(For Dodge Trucks)
220-20
P5638S02542
JuniorTwinSiteSender
(For Ram Van)
105-10
P5799S02630
JuniorTwinSiteSender
Current Output
4-20ma
P5663S02527
JuniorTwinSiteSender
(For Ford)
20-150
P5849S02269
JuniorTwinSiteSender
Voltage Divider
0-10
P5632S02539
JuniorTwinSiteSender
Switch
240-30
P5347S02040
JuniorTwinSiteSender
Switch 1/8 Tank
P5679S02560
JuniorTwinSiteSender
(For Ram Truck)
112-6
Description
5015S01403
5015S00480
5016S00445
5137S01262
4" Dial Chamber - Combo fo LPG & NH3 - Rough Rider - 5% to 95%
221
Gauge Accessories
Magnetel Mounting Flanges
Tank-mounting flanges are not included with Magnetel Gauges
and should be ordered separately.
NOTE: Flanges welded to tank with top and bottom holes on
the vertical centerline are standard with Rochester Gauges.
When the flange is attached so that the bolt holes span the centerline (see drawing at the right), add the prefix X to the
Magnetel gauge model number.
Magnetel Mounting
Part #
Description
"A"
"B"
"C"
0022-00029
Forged Steel
2 1/2" NPT Threaded
Neck Flange
2 1/2"
0022-00030
Forged Steel
Welding Flange Only
0022-00500
Forged Steel
Welding Flange Only
1 3/16"
Weld
2 5/16"
0022-00525
2 1/2"
2" NPT
2 1/16"
1 2
2 5/16"
/ " NPT
Straddle
Bolt holes span center line
Center Line
Bolt holes on center line
4 4"
Part #
Description
"A"
"B"
"C"
A
1"
0022-05210
Forged Steel
Welding Flange Only
1"
Weld
1 21/32"
0022-05211
Forged Steel
Welding Flange Only
1"
2" NPT
1 21/32"
Description
0003-00005
0003-00408
0015-00010
0015-00451
0015-00019
0040-00413
0093S00001
0093-00403
Magnetel Transmitter
This transmitter is designed to fit Rochester model 6342 and 6360
Magnetel Float gauges with 8" dials. The transmitter provides a
current output of 4-20 mA proportional to the liquid volume in a
horizontal storage tank.
Part #
Description
R6315-00012
4-20 ma Transmitter
222
Gauge Accessories
Description
0023S00001
0023S00002
0023S00003
Screws
Part #
Description
0040-00414
0040-00415
0040-00413
0040-00416
0040-00478
Gaskets, LP Gas
Flat Buna N
Part #
Description
0015-00004
0015-00007
0015-00019
Spiralwound gasket,
tef lon filled for SS head
0015-00022
0015-00021
223
Pressure Gauges
Pressure Gauges
Especially designed in a variety of sizes and construction for the LP Gas & anhydrous ammonia industry.
Pressure
Range
Part Number
Dial Size
Case Material
Connection
Brass
1/4 M. NPT
2411
3226A-3
0-30#
J1442
1/4 Bottom
J2042
2434-2
1/4 Back
Steel
2434A-2
35 w.c. &
20 oz. (dual)
29276
0-35 w.c.
5575
J1446
1/4 hose
948
Brass
1/4 M. NPT
Steel
1/4 Bottom
Brass
1/4 M. NPT
0-60#
2
J1448
5576
0-100#
1178
2-1/2
J1458
948
J2058
1/8 hose
2-1/2
Steel
1/4 Bottom
0-300#
1/4 M. NPT
1/4 Back
Brass
J5563
J1458
4-1/2
J1446
1/4 Bottom
Pressure
Range
1008AL-300
0-300#
Di al
Size
Case
Material
Connection
1 4
/ " bottom
Steel
1008AL-400
1008SB-400
2"
0-400#
Stainless
Steel
1008SSB-400
/4" back
Pressure
Range
W0160
0-60#
W0162
0-150#
W0164
0-400#
Di al
Size
Case
Material
Connection
1008AL-400
2 1/2"
Stainless
Steel
1 4
/ " bottom
W0164
Accuracy
0 - 20
+/- 2%
of Water of full scale
Overpressure
Temperature
Limits
Dial
Size
Case
Material
25 psig
20 to 140
Die Cast
Aluminum
Note: Do Not use with Hydrogen gas. Dangerous reactions will occur.
224
Mounting
Connection
Orientation
Vertical
1/8 F. NPT
Description
Size
1449
Stainless Steel
Part
Number
Description
1212 KIT
Needle Valves
These valves are high quality, true throttling valves. Unlike most so-called needle valves,
both the body seat and stem are tapered to provide fine, precise control over a wide range
of adjustment without stem galling.
The 1224 may be used as a small, inexpensive shut-off valve between a pressure gauge
and bulk storage container to allow for convenient gauge replacement.
The 1314, 1316 and 1318 provide taper pipe thread by left hand hose connection threads
and are useful in a wide range of torch and fuel burner applications where an accurate throttling action is required.
Par t
Number
Inlet
Connection
14
1224WA
1314WA
1316WA
1318WA
Part #
V-332
V-333
V-334
V-335
V-3055P
V-880P
" M. NPT
9 16
"-18 L.H.
14
" M. NPT
Inlet end
1/4"
female pipe
1/4"
1/4"
" M. NPT
" M. NPT
14" M. NPT
916"-18 L.H.
18
1 916"
1 34"
female pipe
male pipe
female pipe
1/4"
male pipe
female pipe
Length
Outlet end
1/4"
1/4"
male pipe
Height
14
male pipe
1/4"
1/4"
Outle t
Connection
1/4"
female pipe
1/4"
male pipe
225
Standard Features
12" MNPT
Dual Scale Calibration:
-90 to +130F, -70C to +50C, other ranges available
.08"
Part #
Description
"A"
Dimension
1750-00114
1750-00115
1750-9
4"
6"
2" Bimetallic
Thermometer
9"
1750-12
12"
Flow Indicator
Indicates direction of flow of compatible liquids in pipelines at
working pressures up to 600 psig up to 160F. The indicator
must be installed in pipeline tees.
Length
6286-00325
3 1/4"
6286-00475
4 3/4"
Tee Size
A
Dimension
3 1/4"
3 1/4"
3 1/4"
4 3/4"
1 2
1 2
1 2
4 3/4"
4 3/4"
Replacement Dial
The distance from the top of the mounting adapter to the end of the vane is the
A dimension. This dimension is dependent on the tee size, as shown above.
226
Part #
5013S00048
The Centeron controller receives wireless signals from Centeron monitor and then sends the data to the district host center or to our secure data
center for use in operations management.
Centeron Controller features:
1. Uses DSSS broadband technology which is far superior to any other available
2. Easily attaches to any phone
3. Will not interrupt a conversation in progress
4. Can be remotely programmed for tank level thresholds, call windows
and telephone numbers.
5. Unique phase and diverse antenna arrangement eliminates noise, fading,
and signal blocking commonly found when using narrow band technology
The data center operates with a Call Block plan. This plan will allow all of your controllers to collectively draw from one block of prepaid calls. A
wide variety of Call Blocks will be offered in order to satisfy all Centeron customers. Inherent benefits of this plan include:
One simple invoice for all of your data center fees
Current data for Call Block usage available online
Multiple controllers collectively draw from the same Call Block
Reduction in price you pay per call
Refunds available for unused calls upon cancellation of service
For Domestic applications
Select: 1. Transmitter & specify signal intervals.
2. Controller with or without Temperature sensor.
3. Appropiate type of domestic gauge dial(s).
Description
Pkg. includes: Base Station, Remote Monitor (Dial NOT included)
Description
Pkg. includes: TM-GM60, TM-TC1NT, 5909S02733
Pkg. includes: TM-GM60, TM-TC1NT, 5987S02787
TM-RS-228
Intervals in Minutes
60
120
240
TM-GM60
Controller/Receiver
Part #
TM-TC1T
TM-TC1NT
TM-TC4NT
TM-TC20NT
Temperature Sensor
Yes
No
No
No
Inputs
1:1
1:1
4:1
20:1
Gauge Dials
TM-TC1NT
Domestic
Part #
5909S02733
5986S02733
5987S02787
5988S02788
Description
Rochester R3D JR Dial
Rochester R3D SR Dial
JY Taylor R3D Style A Dial
JY Taylor R3D Style B Dial
Bulk Storage
Part #
TM-MG8-10
TM-JY10-10
Description
Rochester Gauge with 10 ft. cable
J Y Taylor Dial with 10 ft. cable
5909S02733
5323S02787/88
Accessories
Part #
TM-PC CABLE
TM-GMCABLE-5R
Description
Serial interface cable- Controller to PC RS232 port
Additional 5 ft. cable for AG/UG GM monitors available
227
228