Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Objectives
z
Page 1
Contents
1. Network application and system structure
2. Sub-rack
3. Equipment Cards
4. Common Network Elements and Configuration
5. Equipment Level and Network Level Protection
Page 2
Network Application
OptiX OSN 9500
OptiX OSN 7500
Access layer
Network
terminal unit
Page 3
System Structure
STM-1/STM-4 , E1
IU1
IU1
STM-1/STM-4 ,E1
STM-1/STM-4
Ethernet
E1
IU2
IU2
STM-1/STM-4
Ethernet , E1
IU3
STM-1/STM-4
Ethernet , E1
IU4
Ethernet , E1
Cross-connect
STM-1/STM-4
Ethernet , E1
Ethernet ,E1
IU3
Unit
1616VC4
IU4
Clock unit
SCC unit
NM interface
Orderwire unit
Orderwire phone
Page 4
System function
z
Weight : 8Kg
3STM46STM1O/E
Multi-protection
ATM-VP-ring/SDH Protection
Page 5
Contents
1. Network application and system structure
2. Sub-rack
3. Equipment Cards
4. Common Network Elements and Configuration
5. Equipment Level and Network Level Protection
Page 6
Sub-rack
Outer View of 155/622H(Metro 1000)
The dimensions of the chassis are 436 mm (W) x 293 mm (D) x 86 mm (H).
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 7
Sub-rack
Equipment appearance
1
2
1. Chassis
2. Fan board
3. Board area
Board Assignment
IU 3
FAN
IU 2
IU 1
POI
IU 4
SCB
Page 8
Contents
1. Network application and system structure
2. Sub-rack
3. Equipment Cards
4. Common Network Elements and Configuration
5. Equipment Level and Network Level Protection
Page 9
Equipment Cards
z
1. PDH Unit
4. SCB
2. SDH Unit
5. Power Unit
3. Ethernet Unit
6. Fan Unit
Page 10
PDH Unit
Board
SP1S
SP1D
SP2D
PD2S
PD2D
PD2T
Full name
4-channel E1 electrical
interface board
8-channel E1 electrical
interface board
16-channel E1 electrical
interface board
16-channel E1 electrical
interface board
32-channel E1 electrical
interface board
48-channel E1 electrical
interface board
Available slot
IU1 IU2 IU3
IU4
IU4
IU4
Interface type
120 ohm/75 ohm E1
interface
120 ohm/75 ohm E1
interface
120 ohm/75 ohm E1
interface
120 ohm/75 ohm E1
interface
120 ohm/75 ohm E1
interface
120 ohm/75 ohm E1
interface
Page 11
PDH Unit
SP1S/SP1D
SP2D
PD2T
PD2D
PD2S
Page 12
PDH Unit
Alarm List
Alarm name
Alarm description
Alarm level
BD_STATUS
Major
HP_LOM
Major
T_ALOS
Major
TU_AIS
Major
TU_LOP
TU loss of pointer
Major
LP_PS
Major
BIP_EXC
Minor
BIP_SD
Minor
LOOP_ALM
Loop alarm
Minor
LP_RDI
Minor
LP_REI
Minor
LP_UNEQ
Minor
Page 13
Ethernet Unit
Board
Full name
Available slot
Interface type
ET1
IU4
interface board
EF1
switching/VLAN
IU4
interface board(2*O+4*E)
ET1D
interface board
Page 14
Ethernet Unit
Page 15
Ethernet Unit
Functions of Ethernet card
z
Map 18 10M/100M Ethernet services into 148 VC-12s. The maximum uplink
bandwidth is 622.080 Mbit/s at the SDH side. Provide 16 VCTRUNKs.
Providing security isolation among users, and security isolation among VLANs
within one user (one ET1 board supports up to eight users) .
The ET1 board provides multiple inloop and outloop methods to enable fast and
effective trouble shooting .
Page 16
Ethernet Unit
Indicator Description of Ethernet card
No.
Silkscreen
Description
Remarks
The indicator (yellow) is on when data is passing by the network interface link.
indicator
2
RUN
The indicator (green) is on when the network interface connects with a network
indicator
cable.
On for 100ms and off for 100ms: The board is not in service.
On for two seconds and off for two seconds: The board is offline.
On for one second and off for one second: The board works normally.
ALM
Off: No alarm.
Flash three times every other second: Critical alarm.
Flash twice every other second: Major alarm.
Flash once every other second: Minor alarm.
The alarm indicator and the running indicator are on for one second and off for
one second at the same time: Waiting for loading software.
The alarm indicator and the running indicator are on for 100ms and off for
100ms at the same time: Loading software.
Page 17
Ethernet Unit
Alarm List
Alarm Name
Alarm description
Level
ETH_LOS
Critical
PROTOCOL_MM
Critical
TU_AIS_VC3(VC12)
TU alarm indication
Major
TU_LOP_VC3(VC12)
TU pointer lost
Major
BIP_EXC
Minor
BIP_SD
Minor
LOOPALM
Loopback alarm
Minor
LP_RDI_VC3(VC12)
Minor
LP_REI_VC3(VC12)
Minor
LP_UNEQ_VC3(VC12)
Minor
Page 18
SDH Unit
Board
OI2S
Full name
1-channel STM-1
optical interface
Available slot
IU1IU2IU3
boardSTM-1
2-channel
OI2D
optical interface
IU1IU2IU3
boardSTM-4
1-channel
OI4
optical interface
IU1IU2IU3
boardSTM-4
1-channel
SLE
optical interface
Interface type
Ie-1, S-1.1, L-1.1, L-1.2,
SC/PC
Ie-1, S-1.1, L-1.1, L-1.2,
SC/PC
Ie-4, S-4.1, L-4.1, L-4.2,
SC/PC
IU1IU2IU3
boardSTM-4
2-channel
SDE
optical interface
board
IU1IU2IU3
Page 19
SDH Unit
Fiber connection indicator
OI2S/OI4
622M
S-1(4).1
L-1(4).2
155M
I-1(4).0
L-1(4).1
(a)
West
OI2D
155M
I-1(4).0
L-1(4).1
622M
S-1(4).1
L-1(4).2
East
155M
I-1(4).0
L-1(4).1
622M
S-1(4).1
L-1(4).2
(b)
155M
I-1(4).0
L-1(4).1
622M
S-1(4).1
L-1(4).2
Page 20
SDH Unit
Functions of SDH cards
Support optical interface inloop and outloop for fast fault location.
Page 21
SDH Unit
Alarm List
Alarm name
Alarm description
Alarm level
R_LOF
Critical
R_LOS
Critical
MS_AIS
Major
APS_INDI
Major
AU_AIS
AU alarm indication
Major
AU_LOP
AU loss of pointer
Major
B2_EXC
Major
B3_EXC
Major
BD_STATUS
Major
HP_LOM
Major
MS_RDI
Minor
HP_RDI
Minor
Page 22
SDH Unit
Alarm List
Alarm name
Alarm description
Alarm level
B1_EXC
Minor
B1_SD
B1 signal deterioration
Minor
B2_SD
B2 signal deterioration
Minor
B3_SD
B3 signal deterioration
Minor
HP_SLM
Minor
HP_TIM
Minor
HP_UNEQ
Minor
J0_MM
Minor
LOOP_ALM
Loopback alarm
Minor
MS_REI
Prompt
HP_REI
Prompt
Page 23
SCB
No.
Silkscreen
Description
SYNC 1/2
RST
RESET button
Equipment indicators
161
DIP switch
ALM CUT
MODEM
MODEM interface
RS-232 2
RS-232 1
10
ETHERNET
11
PHONE
Page 24
SCB
Functions of SCB card
z
The system control board (SCB) combines the SCC unit, cross-connect unit,
clock unit, orderwire unit, Auxiliary unit.
Page 25
Board Area
IP address & ID
How is the network element physical ID designed?
The 16 digits DIP switch is used to set the physical ID of an NE
ON
OFF
D7 D6 D5 D4 D3 D2 D1 D0
Page 26
Board Area
Making the Network Cable
Standard cable & Crossover cable
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
No.
8 7 6 5 4 3 2 1
.
ETHERNET
Page
27
Signal
TX+
TX-
RX+
RX-
SCB
Timing
unit
Crossconnect unit
IU1
IU2
IU3
IU4
SCC unit
Cross-connect
control register
IU1
IU2
IU3
16 16 data space
division crossconnect matrix
IU4
16 16 data
indication signal
cross-connect
matrix
Cross-connect
control register
Timing
unit
SCC unit
Page 28
SCB
Alarm List
Alarm name
Alarm description
Alarm level
LTI
Major
SYNC_C_LOS
Major
POWER_FAIL
Major
FAN_FAIL
Fan failure
Major
Page 29
Contents
1. Network application and system structure
2. Sub-rack
3. Equipment Cards
4. Common Network Elements and Configuration
5. Equipment Level and Network Level Protection
Page 30
Contents
4. Common network elements
4.1 Terminal multiplexer (TM)
4.2 Add and drop multiplexer (ADM)
4.3 Multi-add and drop multiplexer (MADM)
Page 31
TM
STM-1/4/16/64
Page 32
TM
z
Applications:
Point-to-Point Network
Chain Network
Ring-Chain Combination
TM
ADM
TM
TM
TM
ADM
ADM
ADM
TM
ADM
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 33
TM
z
Configure a TM:
PD2T: IU 4
OI2S: IU 1
IU3
IU2
IU1-OI2S
IU4-PD2T
IU9-X42
IU10-STG
IU11-SCC
Page 34
IU12-OHP2
ADM
STM-1/4/16/64
STM-1/4/16/64
Page 35
ADM
z
Applications:
Chain Network
Ring Network
ADM
TM
ADM
TM
ADM
ADM
ADM
ADM
Page 36
ADM
z
Configure an ADM:
PD2T: IU4
OI2S: IU1,IU2
IU3
IU2-OI2S
IU1-OI2S
IU4-PD2T
IU9-X42
IU10-STG
IU11-SCC
Page 37
IU12-OHP2
MADM
MADM
ADM
ADM
Page 38
MADM
STM-1/4/16/64
STM-1/4/16/64
...
STM-1/4/16/64
STM-1/4/16/64
Page 39
MADM
z
IU3-OI2D
IU2-OI2S
IU1-OI2S
IU4-PD2T
IU9-X42
IU10-STG
IU11-SCC
Page 40
IU12-OHP2
Contents
1. Network application and system structure
2. Sub-rack
3. Equipment Cards
4. Common Network Elements and Configuration
5. Equipment Level and Network Level Protection
Page 41
Failed
Power switch
Input PWR1
Power interface
Input PWR2
Power interface
Grounding terminal
Page 42
Linear MSP
Supports 1+1 and 1:N (1 N 3) protection schemes in the point-topoint linear network topology.
D o u b le
TM
D o u b le
TM
P r o te c tio n
Page 43
A C
S 1 /P 2
S 2 /P 1
A
B
D
C
S 2 /P 1
S 1 /P 2
C A A C
Page 44
Working
SNC
Sub-network
1
SNC
Starting
Node
SNC
Termination
Node
Selector
NE A
Protection
SNC
NE B
Sub-network
2
SNCP Protection
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.
Page 45
When there are more than one routes existing between the
rings, inter-ring service protection can be enabled.
SNCP and MSP ring, SNCP and SNCP ring
Page 46
STM-4
STM-4
MSP ring
STM-1
SNCP
STM-1
SNCP
Page 47
Summary
z
Product Introduction
Features
Thank you