Neutral-Grounding-Resistor Monitoring
Resistor Monitoring
CT
ER SERIES
NGR
Ground-Fault Monitoring
SE-330 SERIES
(Sensing Resistor)
L1
L2
(NGR Monitor)
Ordering Information
POWER
SUPPLY
ORDERING
NUMBER
SE-330
SE-330
for all apps.
35 kV or less
SE-330HV
for 72 kV
apps.
K4 UNIT HEALTHY
CONTACT
COMM
0=USB Only
1=DeviceNet
3=EtherNet
(Dual RJ45)
4=EtherNet
0=120/240 (SC Fiber & RJ45)
Vac/Vdc 5=EtherNet
(Dual SC Fiber)
2=48 Vdc 6=IEC61850
(Dual RJ45)
7=IEC61850
(SC Fiber & RJ45)
8=IEC61850
(Dual SC Fiber)
ACCESSORIES
REQUIREMENT
Required
Required
Optional
Optional
Optional
Optional
Optional
Optional
0=Normally Open
1=Normally Closed
Accessories
A
Littelfuse reserves the right to make product changes, without notice. Material in this document is as accurate as known at the time of publication. Visit Littelfuse.com for the most up-to-date information.
Rev: 4-D-043015
Based on SE-330 Manual Rev: 10-J-062215
Based on SE-330 HV Manual Rev: 5-H-062215
IEEE #
3
Detects resistor failure within seconds, reduces transient-overvoltage risk, removes risk of ground-fault-detection failure
50G/N, 51G/N,
59N
Ground-fault detection
BENEFITS
Main or backup protection to detect a ground fault anywhere on the monitored system
Select greatest sensitivity without false operation, adjustable in 1% increments (MEM setting)
Universal CT compatibility
Output contacts
Two Form C (Ground Fault, Resistor Fault), Two Form A (Trip/Pulse, Healthy)
Trip records
On-board 100-event (with date and time) recorder helps with system diagnostics
Local communications
Mini USB port to view measured values, configure settings, and check event records
Data Logging
On-board microSD card (included) can be used for long-term data logging
Network communications
Remotely view measured values and event records, reset trips, and cause a remote trip
Available Protocol Options:
IEC 61850 - with dual RJ45, SC Fiber and RJ45, or Dual SC Fiber Interface
Modbus TCP and Ethernet/IP - with dual RJ45, SC Fiber and RJ45, or Dual SC Fiber Interface
DeviceNet - with CAN interface
Software
Selectable contact
operating mode
Selectable reset mode
Calibrate push button
Unit-healthy output
Conformal coating
Typical Values
NEUTRAL-GROUNDING RESISTOR
SYSTEM
VOLTAGE
(VOLTS)
CURRENT
(AMPERES)
5
5
5
5
10
15
480
600
2,400
4,160
7,200
14,400
RESISTANCE
(OHMS)
55
69
277
480
416
554
SENSING RESISTOR
MODEL
ER-600VC
ER-600VC
ER-5KV
ER-5KV
ER-15KV
ER-15KV
RESISTANCE
(SWITCH S5 SETTING)
20 k
20 k
20 k
20 k
100 k
100 k
GROUND-FAULT
PICKUP LEVEL
(AMPERES)
VN PICKUP LEVEL
(VOLTS)
2.5
2.5
2.5
3
2
3
170
200
800
1,700
170 x 5 = 850
340 x 5 = 1,700
DISCLAIMER: The above table is for illustrative purposes only. Actual values may differ based on a variety of individual system considerations, such as capacitive charging current and coordination study results.
Wiring Diagram
CONTROL
POWER
UNIT
HEALTHY
1
2
RESET
15
NEUTRAL-GROUNDINGRESISTOR MONITOR
SE-330 SERIES
SENSING RESISTOR
ER SERIES
(required)
R
13
POWER SYSTEM
NEUTRAL (X0)
Specifications
12
16
17
+24 Vdc 18
ANALOG
OUTPUT
4-20 mA
+ 19
20
0 V 21
TRIP OR
PULSING
22
23
(K1)
CURRENT TRANSFORMER
EFCT FAMILY
(required)
EFCT
1A
10
5A
11
COMMON
24
GROUND
FAULT
25
(K2)
26
27
RESISTOR
FAULT
28
(K3)
29
PULSE
(SE-330 ONLY)
ENABLE
Littelfuse reserves the right to make product changes, without notice. Material in this document is as accurate as known at the time of publication. Visit Littelfuse.com for the most up-to-date information.
Rev: 4-D-043015
Based on SE-330 Manual Rev: 10-J-062215
Based on SE-330 HV Manual Rev: 5-H-062215