REPORT OF TEST

Accreditation No. 754


Accredited for compliance with ISO/IEC 17025
This document is issued in accordance with
NATAs accreditation requirements. The tests,
calibrations or measurements contained herein are
traceable to Australian national standards of
measurement.

JOB CODE:

10345402

REPORT NUMBER:

MI-0783-11

TEST DATE:

29 April 2011

REPORT DATE:

10 May 2011

TESTS ON:

HIGH PRESSURE SODIUM LAMPS

RATING:

400 W

LAMP TYPE:

See Results

PARAMETERS
MEASURED

Input Voltage
Input Current
Input Power
Power Factor

TESTED FOR:

The Active Reactor Company Pty Ltd


6 Locksley Avenue
KEW

CLIENT REFERENCE:

Lamp Voltage
Lamp Current
Lamp Power
Power Factor

Order No.: Email 11th April 2011

NATURE OF TESTS:

Determination of the Lamp Operating parameters, when used in conjunction with


Active Reactor ballast control gear or Standard 400 W Inductive ballast control gear
at a nominal test voltage of 254.4 V.

UNCERTAINTY
OF TEST:

The estimated uncertainty in determination of test results, at time of measurement, is:


0.3 % of reading for voltage and current
0.5 % of reading for power
0.005 for power factor
The uncertainty values stated in this document have been calculated at the 95% level of confidence with a coverage factor k = 2.0
This means that the chance that a result is in error by more than the value of its uncertainty is not more than five in one hundred.

CONCLUSION:

Test results are given on pages 3 to 6

This report consists of 6 page(s).


This report must not be reproduced except
as a complete document.
Ref: PF 3896
Pc,/pc

Quote No:
Chkd:

Anthony Dyke
NATA approved signatory
DATED:

13 / 05 / 2011

Page 2

Total Pages:
Report Number:
Report Date:

6
MI-0783-11
10 May 2011

TECHNICAL SOLUTIONS
TEST CONDITIONS :
1.

Ambient Temperature: 22 2 C

2.

Test Frequency AC Supply 50 Hz

3.

Test Supply Total Harmonic Distortion < 1.5 %

4.

Test Voltage: 254.4V

TEST NOTES:
1.

The test lamp is allowed to thermally stabilize under test supply for not less than 60 minutes
prior to tests.

TEST LANTERN:
Make:

Sylvania Roadstar
No Control gear in lantern

CONTROL GEAR:
Standard Gear:

Ballast:
Ignitor:
Capacitor:

Tridonic Atco OGS400-50


Tridonic Atco ZRM 4,5-ES/D
Ultra-Tech Electocics, 45F CP45M-576

Active Reactor
Gear:

Main Ballast:
Control Ballast:
Ignitor:
Capacitor:

Active Reactor Art No. 89003644


Active Reactor Art No. 89003646
Tridonic Atco ZRM 4.5ES/C
Comar Condensatori 50F

TEST LAMPS:
Lamp No

Make:

Type:

Rating:

Lamp 400-21-2:
Lamp 400-2-1:
Lamp 400-17-1:
Lamp 400-1-1:
Lamp 400-8-1:

SYLVANIA
SYLVANIA
OSRAM
OSRAM VIALOX
OSRAM VIALOX

SHP-T 400W SBY


SHP-T 400W SBY
NAV -TT(SON-T-NG)
NAV (SON)-T
NAV-TT

400 W
400 W
400 W
400 W TT
400 W

Total Pages:
Report Number:
Report Date:

Page 3

6
MI-0783-11
10 May 2011

TECHNICAL SOLUTIONS
TEST RESULTS
1.

400 W Standard Control gear

Lamp
No.

Control Gear

Lamp 400-21-2:
Lamp 400-2-1:
Lamp 400-17-1:
Lamp 400-1-1:
Lamp 400-8-1:

Std Inductive Ballast


Std Inductive Ballast
Std Inductive Ballast
Std Inductive Ballast
Std Inductive Ballast

Voltage
(Vrms)
254.4
254.4
254.4
254.4
254.4

Supply Parameters
Current
Power
(Arms)
(W)
1.912
1.919
1.930
1.960
1.976

452.5
462.4
474.5
489.9
491.8

Power Factor

Voltage
(Vrms)

0.930
0.947
0.966
0.982
0.978

101.9
106.7
114.1
125.7
136.4

Lamp Parameters
Current
Power
(Arms)
(W)
4.619
4.541
4.417
4.203
4.004

404.3
416.0
430.4
451.0
456.0

Power Factor

0.858
0.858
0.854
0.854
0.835

Total Pages:
Report Number:
Report Date:

Page 4

6
MI-0783-11
10 May 2011

TECHNICAL SOLUTIONS
TEST RESULTS: (contd)
2.

Active Reactor Control gear

Lamp
No.

Control Gear

Lamp 400-21-2:
Lamp 400-2-1:
Lamp 400-17-1:
Lamp 400-1-1:
Lamp 400-8-1:

Active Reactor Ballast


Active Reactor Ballast
Active Reactor Ballast
Active Reactor Ballast
Active Reactor Ballast

Voltage
(Vrms)
254.4
254.5
254.4
254.4
254.4

Supply Parameters
Current
Power
(Arms)
(W)
1.434
1.441
1.455
1.505
1.593

334.3
342.9
348.5
358.0
362.8

Power Factor

Voltage
(Vrms)

0.916
0.934
0.941
0.935
0.895

75.5
80.1
84.2
91.4
103.2

Lamp Parameters
Current
Power
(Arms)
(W)
4.402
4.261
4.154
3.979
3.662

277.7
287.1
294.7
309.2
318.5

Power Factor

0.836
0.840
0.843
0.850
0.842

Total Pages:
Report Number:
Report Date:

Page 5

6
MI-0783-11
10 May 2011

TECHNICAL SOLUTIONS
TEST RESULTS: (contd)
Graph of Input Power vs Lamp Voltage

High Pressure Sodium Lantern Data


Input Power (Watts) v's Lamp Voltage
At test voltage of 254.4 Vrms , 50 Hz
500.0

450.0

400.0
Input Power (W)

3.

254.4V Std Ballast

350.0

254.4V Active Ballast


Poly. Active Ballast
Poly. Standard Ballast

300.0

250.0

200.0
50.0

60.0

70.0

80.0

90.0

100.0

110.0

Lamp Voltage (Vrms)

120.0

130.0

140.0

150.0

Total Pages:
Report Number:
Report Date:

Page 6

6
MI-0783-11
10 May 2011

TECHNICAL SOLUTIONS
TEST RESULTS: (contd)
4.

Active Reactor Control gear with variation in Supply Voltage

Lamp
No.

Control Gear

Lamp 400-21-2:
Lamp 400-21-2:
Lamp 400-21-2:
Lamp 400-21-2:

Active Reactor Ballast


Active Reactor Ballast
Active Reactor Ballast
Active Reactor Ballast

254.4
250.0
240.0
230.0

1.426
1.456
1.536
1.618

Lamp 400-8-1:
Lamp 400-8-1:
Lamp 400-8-1:
Lamp 400-8-1:

Active Reactor Ballast


Active Reactor Ballast
Active Reactor Ballast
Active Reactor Ballast

254.4
250.0
240.1
230.0

1.597
1.601
1.618
1.648

Voltage
(Vrms)

Supply Parameters
Current
Power
(Arms)
(W)

Lamp Parameters
Current
Power
(Arms)
(W)

Power Factor

Voltage
(Vrms)

Power Factor

332.1
329.9
326.3
322.0

0.915
0.906
0.885
0.865

74.9
74.8
74.8
74.6

4.387
4.394
4.410
4.412

274.4
273.4
272.0
269.6

0.835
0.831
0.825
0.819

363.0
361.2
356.6
352.0

0.893
0.902
0.918
0.928

103.7
103.9
104.0
104.0

3.669
3.680
3.698
3.717

320.1
319.2
316.5
313.8

0.841
0.835
0.823
0.811