Arctic Control provides remote monitoring and control of

several switchgears and disconnectors. In addition to the


direct switchgear controlling and monitoring capability Arctic

....
..
....

Control has many special features like:


Charging and condition monitoring of external battery
Overcurrent detection for protection of switchgear
motor fuses

Arctic Control

Compliant to IEC-104 communication protocol for


SCADA communication

Makes the existing medium voltage network


ready for future Smart Grid requirements.

High level of communication security

Reliable GPRS/EDGE communication with automatic


monitoring and connection re-establisment

Deploying Arctic Control to medium voltage distribution


network overall quality improvement is achieved by
reduced blackout times, better network status information

Remote Wireless Control for


Electricity Distribution Network Assets

for preventive maintenance as well as remote control of


remote sites. All these lead also to direct cost savings when
the life-cycle of existing primary devices are extended and
unnecessary site visits can be avoided.

The Arctic Control Solution enables cost-optimized control and monitoring of


medium voltage network assets such as disconnectors, load break switches and
ring main units in energy distribution networks. It provides always-on wireless
connectivity together with the intelligence needed for disconnector control and
monitoring, and also with supporting features such as battery charging and
condition monitoring.
Wireless connectivity is implemented via commercial mobile networks, thus
reducing investment and operational costs. Used in conjunction with always-on
communication from a SCADA system, this method achieves an ideal combination
of local and centralized intelligence for real time systems in a cost-efficient way.
SECURE VPN TUNNEL
IEC-104
Viola M2M
Gateway

RS232/422/485
IEC-101
Arctic Control

Disconnector

..
..
..
..
..
..
..
..
..
..
..

Control of 13 disconnector
switches or switchgears
Protocol conversions from
IEC101 to IEC104 and from
Modbus RTU to IEC104
Advanced battery control
(Charging, condition
monitoring)
Measurement of disconnector
transaction time and energy
Motor protection

SOFTWARE

HARDWARE

I/O INTERFACES

NETWORK INTERFACES

ORDERING INFORMATION

..
..
..
..
..
..
..
..
..

..
..
..
..
..
..

..

..
..
..
..
..
..
..
..
..
..
..
..
..
..
..

Code

Product

2320

Arctic Control

2321

Arctic Control (EDGE)

2322

Arctic Control 48VDC (EDGE)

General
IEC-104 protocol support for
SCADA communication
Communication monitoring
and automatic connection
re-establishment
Graphical user interface
(Configuration can be
adjusted remotely)
Cabinet heater control
SSH client

Always on two-way
communication
based on GPRS
Supports both local and
remote disconnector control
LED indication for
disconnector and
grounding status
Reliable and secure
communication
Robust aluminium casing
DIN rail mounting

APPLICATION
EXAMPLES

..

Disconnectors, reclosers,
switchgears, RMUs

Battery testing
Switch off charger
Switch on the dummy load
Measurement of current and
voltage for a defined period
The results are reported in
IEC-104 messages to the
control room

Overcurrent detection
and shut-down

..

Software fuse functionality:


Load current and duration
measurement protects the
motor by shutting off power
to it before the motors own
fuse blows

Protection against complete


battery discharge

..

DIMENSIONS

177 mm

If the measured battery


voltage is below a defined
limit an IEC-104 event is sent
and battery is disconnected.

CONFIGURATION &
MANAGEMENT
150 mm

135 mm

Arctic Control can be configured


with a graphical user interface
with an internet browser or via a
conventional console interface
(Telnet or via serial console).

Processor Environment
32 bit RISC processor
8 MB FLASH memory
32 MB SDRAM memory

Power consumption
10 W (when not charging)

Other
Temperature sensor
Real time clock

Environment
Temperature ranges:
40 to +75 C
40 to +85 C (storage)
Humidity 5 to 85 % RH
Approvals: CE

SERIAL PORTS

..
..
..
..
..
..
..
..
..

Serial 1 / Console / IEC-101


RS-232 DTE,
Male DB-9 connector
Full serial and
modem signals

Default configuration
15 digital inputs for
disconnector status control
(5 per disconnector):
open/closed, local/remote
use, grounding open/closed

..
..
..
..
..
..
..
..

6 relay outputs for open/


close the disconnector
(2 per disconnector)
1 relay output for the load
cut (motor protection)
2 analog inputs:
1 for load measurement,
1 extra for other use
1 relay output for test load
of the battery test
1 relay output for the
external heater
2 extra general purpose
digital inputs for other use
1 extra general purpose
relay ouput for other use
Total number of inputs /
outputs: 17 digital in, 10
relay out and 2 analog in

Ethernet
10/100 Base-T. Shielded RJ-45
1,5 kV isolation transformer
Ethernet IEEE 802-3, 802-2

GPRS (2320)

OPTIONS

Quad band
GSM850/900/1800/1900
GPRS multi-slot class 12

Code

Product

GPRS mobile station class B

3410

Magflex antenna with 2,5 m cable

Max. 85.6 kbps GPRS


downlink and uplink speed

3551

Rooflex (puck) antenna with


2,5 m cable

Coding schemes CS1-4

GPRS/EDGE (2321, 2322)

Speed 300 460 800 bps


Data bits 7 or 8

Quadband
(850/900/1800/1900 MHz)
EDGE class 10: max 236.8
kbps (downlink)
Mobile station class B
Modulation and coding
scheme MCS 1-9
Mobile station class B
Coding schemes CS 1-4
FME external antenna
connector (50)
(Stub antenna included)

Ordering address:

Stop bits - 1 or 2
Parity - None, Even, Odd
Flow control None,
RTS/CTS
Protection 15 kV ESD
and short circuit
Console RS-232,
19200 bps, 8 data bits,
1 stop bit, no parity (8N1)

..

Serial 2 / IEC-101
Such as serial port 1 but
also the RS-422 and RS-485
(selectable) modes are
supported

PRODUCT VARIANT TABLE


Feature
GPRS

Viola Systems Ltd.


Lemminkisenkatu 14 - 18 B
FI-20520 Turku, Finland

2320

2321

2322

Phone + 358 (0)20 1226 226


Fax + 358 (0)20 1226 220

sales@violasystems.com

EDGE
Power supply 90-264 VAC
or 85-200 VDC

Power supply 24 VDC 48 VDC

Battery charging

Battery test

24 VDC output

www.violasystems.com

2013-12-18