MULTIPLE-CHOICE QUESTIONS AND ANSWERS


1. In a transformer (a) All turns are equally insulated (b) The end turns are more strongly insulated (c) The
end turns are closely w ound (d) The end turns are w idely separated
2. Laminated insulations coated w ith varnish are normally used in the transformer (a) To reduce
reluctance of magnetic path (b) To reduce the effect of eddy current (c) To increase the reluctance of
magnetic path (d) To reduce the hysteresis effect
3. The required thickness of lamination in a transformer decreases w hen (a) The applied frequency
increases (b) The applied frequency decreases (c) The applied voltage increases (d) The applied
voltage decreases
4. Oil in transformer is used to (a) Transfer electrical energy (b) Insulate the w indings (c) Cool the
w indings (d) None of the above
5. The follow ing arrangement w ill reduce the reluctance of magnetic path of the transformer.
6. The w indings of a transformer are divided into several coils because (a) It is difficult to w ind as one coil
(b) It reduces voltage per coil (c) It requires less insulation (d) None of the above
7. The size and construction of bushings in a transformer depend upon the (a) Size of w inding (b) Size of
tank (c) Current flow ing (d)Voltage supplied
8. Transformer humming sound is reduced by the (a) Proper bracing of transformers assemblies (b)
Proper insulation (c) Proper design (d) Proper design of w inding
9. Sludge in transformer oil is due to (a) Decomposition of oil (b) Decomposition of insulation (c) Moisture
content in oil (d) None of the above
10. A transformer used only for electrical isolation betw een tw o circuits has turns ratio w hich is (a) More
than unity (b) Less than unity (c) Equal to unity (d) More than 0.5
11. If 90 per cent of normal voltage and 90 per cent of normal frequency are applied to a transformer, the
per cent charge in hysteresis losses w ill be (a) 20% (b) 4.7% (c) 19% (d) 21%
12. If 110 per cent of normal voltage and 110 per cent of normal frequency is applied to a transformer, the
percentage change of eddy current losses w ill be (a) 10% (b) 20% (c) 25% (d) 21%
13. A transformer has tw o 2,400 V primary coils and tw o 240 V coils. By proper connection of the
w indings, the transformation ratio that can be obtained is (a) 10 (b) 5 (c) 20 (d) 9
14. A single-phase, 2,200/200 V transformer takes 1 A at the HT side or no load at a pow er factor of 0.385
lagging. The iron losses are (a) 167 W (b) 77 W (c) 88 W (d) 98 W
15. Neglecting resistance, at constant flux density, the pow er required per kilogram to magnetize the iron

studyhard4u.weebly.com/objective-type-questions.html

1/4

1/19/13

Objective type questions - Work Hard...................

core of a transformer is 0.8 W at 25 Hz and 2.04 W at 60 Hz. The pow er required per kilogram for 100
Hz is (a) 3.8 W (b) 3.63 W (c) 3.4 W (d) 5.2 W
16. Select the correct statement: (a) emf per turn of both the w indings are equal (b) emf per turn in HV
w inding is more than the emf per turn in LV w inding (c) emf per turn in HV w inding is less than the emf
per turn in LV w inding
17. The flux involved in the emf equation of a transformer has (a) rms value (b) Average value (c) Total
value (d) Maximum value
18. The no-load current in a transformer lags the applied voltage by (a) 90 95 (b) About 80 85 (c) 0
15 (d) About 110
19. High leakage impedance transformers are used for applications such as (a) Pow er distribution (b)
Electrical toys (c) Arc w elding (d) Fluorescent lamps
20. A transformer 2,000 kVA, 250 Hz is operated at 50 Hz. Its kVA rating should be revised to (a) 400 kVA
(b) 10,000 kVA (c) 2,000 kVA (d) Cannot be revised
21. The transformer w hich w ill have the largest size is
(a) 100 kVA, 25 Hz (b) 100 kVA, 100 Hz (c) 100 kVA, 50 Hz (d) 100 kVA, 60 Hz
22. The magnetic flux of a transformer follow s (a) High reluctance path (b) Low reluctance path (c) Low
conductivity path (d) High conductivity path
23. The efficiency of a transformer is usually in the range of (a) 5060% (b) 6575% (c) 7090% (d) 90
98%
24. Transformer is laminated to reduce (a) Hystersis loss (b) Eddy current loss (c) Partly (a) and partly (b)
(d) Increases exciting current
25. Transformer changes the value of (a) Pow er (b) Frequency (c) Voltage (d) Current
26. Transfer of electrical pow er from primary to secondary in a transformer takes place (a) Electrically (b)
Electromagnetically (c) Magnetically (d) None of these
27. The thickness of a 50 Hz transformer lamination is (a) 0.35 cm (b) 0.35 mm (c) 0.33 m (d) 0.30 cm
28. A pow er transformer is a constant (a) Current device (b) Voltage device (c) Pow er device (d) Main
flux device
29. The value of flux in the emf equation of a transformer is (a) rms (b) Average (c) Maximum (d) Integral
w ave cycle
30. The leakage flux in a transformer depends upon the value of (a) Load current (b) Supply frequency (c)
Mutual flux (d) None of these
31. The voltage regulation of a transformer at full-load 0.8 pow er factor lag is 6 per cent. Its voltage
regulation at full-load 0.8 pow er factor lead w ill be (a) Negative (b) 54% (c) Positive (d) Zero
32. The full-load efficiency of a transformer at 0.85 p.f. lag is 97 per cent. Its efficiency at full load 0.85
bpow er factor lead w ill be (a) 99% (b) 96% (c) 97% (d) 98%
33. If a load on secondary side of a transformer increases, the current on the primary side (a) Remains
constant (b) Increases (c) Decreases (d) None of these
34. If a sinusoidal exciting current is applied to a transformer, the mutual flux produced is
(a) Negative (b) Sinusoidal (c) Zero (d) Flat top
35. To get sinusoidal flux in a transformer the mutual flux produced is (a) Non-sinusoidal (b) Sinusoidal (c)
Direct current (d) Zero
36. A 220V, 150V bulb is connected in series w ith the primary of a 220/1,100 V, 50 Hz transformer. If the
load on the secondary side is disconnected, the brightness of the bulb w ill (a) Decrease (b) Increase
(c) Be unaffected (d) Decrease to a very low value
37. The open circuit test of a transformer gives information about (a) Core losses of the transformer (b) Cu
losses of the transformer (c) Exciting current (d) None of these
38. The short circuit test of a transformer gives the information of (a) Cu losses of the transformer (b) Core
losses of the transformer (c) Winding circuit impedance (d) None of these
39. During testing of a transformer (a) Both SC and OC tests are performed at rated current (b) Both SC
and OC tests are performed at rated voltage (c) OC test is performed at rated voltage (d) SC test is
performed at rated current
40. All-day efficiency of a transformer is (a) Equal to its pow er efficiency (b) Less than its pow er
efficiency (c) More than its pow er efficiency (d) None of these
41. Routine efficiency of a transformer depends upon the value of (a) Load current (b) Supply frequency
studyhard4u.weebly.com/objective-type-questions.html

2/4

1/19/13

Objective type questions - Work Hard...................

(c) Pow er factor of load (d) Both (a) and (b)


42. A ferrite core has less eddy current loss than an iron core because ferrites have (a) Low er
permeability (b) High hysteresis (c) Alnico as the main constituent (d) High resistance
43. The maximum regulation of a transformer occurs at a pow er factor of (a) Unity (b) (c) (d)
44. The zero of regulation of a transformer occurs at a pow er factor of (a) Zero (b) (c) (d)
45. Circular coil sections are used because they (a) Reduce iron material (b) Reduce copper material (c)
Have the strongest mechanical shape (d) All of these
46. A transformer is connected to a constant voltage source. If the supply frequency decreases, the
magnetic flux in the core w ill (a) Increase tow ards saturation (b) Decrease (c) Remain unchanged (d)
None of these
47. The pow er in autotransformer is transferred through (a) Inductive process (b) Convection process (c)
Conduction process (d) All of these
48. The cross-sectional area of the common portion of an autotransformer is (a) Kept constant (b)
Proportionally decreased (c) Proportionally increased (d) None of these
49. The efficiency of an autotransformer for the same output compared to a tw o-w inding transformer is
(a) Greater (b) Lesser (c) Poor (d) None of these
50. The condition for successful parallel operation of transformer is (a) Correct polarity (b) Per unit
impedance based on their rating should be equal (c) Identical voltage and frequency rating (d) Equal
ratio of equivalent resistance to reactance (e) All of these
51. During parallel operation of transformers incorrect polarity w ill result in (a) Open circuit (b) Dead short
circuit (c) Regeneration of pow er (d) Pow er factor of transformer w ill be different from that of the
connected load
52. In an autotransformer of voltage ratio and V1 > V2, the fraction of pow er transferred inductively is (a)
(b) (c) (d)
53. A 10 kVA, 400/200 V sinlge-phase transformer w ith 10 per cent impedance draw s a steady short
circuit line current of (a) 50 A (b) 150 A (c) 250 A (d) 350 A
54. A 400/100 V, 10 kVA tw o-w inding transformer is reconnected as an autotransformer across a suitable
voltage source. The maximum kVA is (a) 50 kVA (b) 15 kVA (c) 12.5 kVA (d) 8.75 kVA
55. An autotransformer having a transformation ratio of 0.8 supplies a load of 10 kW. The pow er
transferred inductively from the primary to the secondary is (a) 10 kW (b) 8 kW (c) 2 kW (d) Zero
56. A single-phase induction regulator is a constant input transformer to obtain smooth variation of the
output voltage by varying the (a) Ratio of turns betw een primary and secondary w inding (b) Frequency
(c) Flux-density in the core (d) Angle betw een the magnetic forces of the primary and secondary
w indings
57. In operating a 400 Hz transformer at 50 Hz (a) Only voltage is reduced in the same proportion as the
frequency (b) Only kVA is reduced in the same proportion as the frequency (c) Both voltage and kVA
rating are reduced in the same proportion as the frequency (d) None of the above
58. In performing the short circuit test of a transformer (a) High-voltage side is usually short-circuited (b)
Low -voltage side is usually short-circuited (c) Any side is short-circuited w ith preference (d) None of
these
59. In performing open circuit test of a transformer (a) High voltage is usually kept open (b) Low voltage is
usually kept open (c) Any side can be kept open (d) None of the above
60. Transformer core usually uses grain-oriented laminated sheets. The grain orientation reduces (a)
Copper loss (b) Eddy current loss (c) Hysteresis loss (d) None of the above
61. In the circuit model of a transformer, the core loss is represented as (a) Series resistance (b) Series
inductance (c) Shunt resistance (d) Shunt inductance
62. While performing short circuit test on a transformer, the impressed voltage magnitude is kept constant
but the frequency is increased. The short circuit current w ill (a) Increase1 (b) Decrease (c) Remain the
same (d) None of the above
63. A transformer has a hysteresis loss of 30 W at 240 V, 60 Hz. The hysteresis loss at 200 V, 50 Hz w ill
be
(a) 20.8 W (b) 25 W (c) 30 W (d) 36 W
64. In a transformer, the exciting current w ill be in phase quadrature w ith the impressed voltage provided
(a) Only the leakage impedance drop is ignored (b) Only the core loss is ignored (c) Both the leakage
and impedance drop and the core loss are ignored (d) Only no-load copper loss is ignored
studyhard4u.weebly.com/objective-type-questions.html

3/4

1/19/13

Objective type questions - Work Hard...................

65. Magnetizing impedance of a transformer is determined by (a) Short circuit test (b) Open circuit test (c)
Both open circuit and short circuit tests (d) None of these
66. A transformer is to be tested at full-load conditions consuming only losses from the mains. We do (a)
Load test (b) Open circuit and short circuit tests (c) Back-to-back test (d) None of these
67. In a transformer operating at constant voltage if the input frequency increases the core loss w ill (a)
Increase (b) Decrease (c) Remain constant (d) Increase as the square of the frequency
68. Grain-oriented laminated sheet steel in a transformer reduces (a) Copper loss (b) Eddy current loss (c)
Hysteresis loss (d) None of above
69. R1 is the resistance of the primary w inding of a transformer. The turns ratio in terms of primary to
secondary is a. The equivalent resistance of the primary referred to as secondary is (a) R1/a (b) a2 R1
(c) R1/a2 (d) None of these
70. Choose the correct statement: (a) emf per turn in high-voltage w inding is more than the emf per turn in
low -voltage w inding (b) emf per turn in both the finding are equal (c) emf per turn in both the w indings
are not equal (d) None of these
71. If E2 and V2 be the induced emf in secondary w inding and V2 be the terminal voltage during load, the
regulation of the transformer is given by (a) (b) (c) (d)
72. One transformer has leakage impedance of 1 + j 4 and 3 + j 4 for its primary and secondary
w indings, respectively. The transformer has (a) Low voltage primary (b) High voltage primary (c)
Medium voltage primary (d) Insufficient data
73. A single-phase transformer has its maximum efficiency at 60 per cent of full load. At full load copper
loss w ill be (a) Equal to core loss (b) Less than core loss (c) More than core loss (d) Zero
74. The flux in a magnetic core is alternating sinusoidally at a frequency of 600 Hz. The maximum flux
density is 2 T and eddy current loss is 15 W. If the frequency is raised to 800 Hz and maximum flux
density reduced to 1.5 T, the eddy current loss w ill be (a) Same (b) Reduced to half (c) Doubled (d)
Increased by 50%
75. The core flux in a transformer depends mainly on (a) Supply voltage (b) Supply voltage and frequency
(c) Supply voltage, frequency and load (d) Supply voltage and load but independent of frequency
Answ ers