Sei sulla pagina 1di 7

EMI Test System

(KH3961/KH3962)

Specification
Global Office of Lisun Electronics Inc.
http://www.Lisungroup.com
Lisun Group (Hong Kong) Limited
Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road, Mongkok, Kowloon,
Hong Kong
Tel: 00852-68852050
Fax: 00852-30785638
Email: SalesHK@Lisungroup.com
Lisun Electronics (Shanghai) Co., Ltd
Add: Room 1210, No. 9 Building, Jiangqiao Wanda Plaza, Hexuan Road, Jiading District,
Shanghai, 201803, China
Tel: +86(21)5108 3341
Fax: +86(21)5108 3342
Email: SalesSH@Lisungroup.com

Lisun Electronics Inc. (USA)


Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A.
Email: Sales@Lisungroup.com
Lisun China Factory
Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China
Tel: +86-189-1799-6096
Email: Engineering@Lisungroup.com

Lead in CFL & LED Test Instruments

Lisun Electronics Inc.

Sales@Lisungroup.com

www.Lisungroup.com

EMI Test System (KH3961/KH3962)


Content Table
Name

EMI Test System


(KH3961)
--------Page 2

Model

Characteristic

EMI Receiver

Frequency=9K-30MHz; Used for electronic


ballast, CFL, LED and other lighting manufactory
design. More than 1,000 units sold in illumination
industry, most of famous company have used
this test instrument, such as Philips, Panasonic,
GE Lighting and etc.

Artificial
Network
Power
Attenuator

EMI Receiver

EMI Test System


(KH3962)
--------Page 3

Artificial
Network
Power

Equipped with artificial network can test


disturbance voltage of mains terminal. The
maximum withstanding current is 10A.
20dB Attenuate, it is an auxiliary accessory to
help test
Testing frequency=9K-300MHZ and this system
is used to test Conductive Emission according to
newly CISPR 15. The instrument complies with
newly European and USA standard, test result
reliable and accurate.
Equipped with artificial network can test
disturbance voltage of mains terminal. The
maximum withstanding current is 10A.

Attenuator

20dB Attenuate ,it is an auxiliary accessory to


help test

Coupling
Decoupling
Network

EMI receiver equipped with coupling /decoupling


network is equivalent to test radiated
electromagnetic disturbance of electric lighting
appliance with frequency from 30M-300mHz

-Page 1 -

Lisun Electronics Inc.

Sales@Lisungroup.com

www.Lisungroup.com

1. Function and technical parameters of KH3961


KH3961 is an automatic EMI receiver. It is a main test system for EMI (Electro Magnetic
Interference) testing. The KH3961 is produced by the full closure structure and strong
electro-conductibility material, which make sure high shielding effect. Due to the new technology
for the EMI Test System, it solved the instrument self-EMI problem. The test results are according
to the international format test report. The EMI Test System KH3962 fully meets CISPRl6-1,
GB17743, FCC, EN55015 and EN55022

Detection frequency range:9kHz~30MHz

Frequency stability: 1x 10-6

Frequency resolution: (9kHz~150kHz) 30Hz; (150kHz~30MHz) 1kHz

Test Tolerance: 2 dB

Measure and Detection method: PK,QP and AV range from 20dBV to 140dBV

Test time: setting by customers

Frequency scanning step length: 20Hz~2M

Sweep bandwidth: 200Hz; 9kHz; 120kHz

Function of Artificial Network Power:

Use 50/50H + 5 single phase analog network according to requirement of international


standard;

Rated work current: 10A;

Power supplied according to load requirement, 220V or 110V optional;

Phase line or null line optional on front panel for test.

-Page 2 -

Lisun Electronics Inc.

Sales@Lisungroup.com

www.Lisungroup.com

2. Function and technical parameters of KH3962


KH3962 is an automatic EMI receiver. It is a main test system for EMI (Electro Magnetic
Interference) testing. The KH3962 is produced by the full closure structure and strong
electro-conductibility material, which make sure high shielding effect. Due to the new technology
for the EMI Test System, it solved the instrument self-EMI problem. The test results are according
to the international format test report. The EMI Test System KH3962 fully meets CISPRl6-1,
GB17743, FCC, EN55015 and EN55022

Detection frequency range:9kHz~300MHz

Frequency stability: 1x 10-6

Frequency resolution: (9kHz~150kHz) 30Hz; (150kHz~30MHz) 1kHz; (150kHz~300MHz)


5kHz

Test Tolerance: 2 dB

Measure and Detection method: PK,QP and AV range from 20dBV to 140dBV

Test time: setting by customers

Frequency scanning step length: 20Hz~2M

Sweep bandwidth: 200Hz; 9kHz; 120kHz

The Next Pages are the Test Report for:


Report 1: KH3961/KH3962 for 9k~30MHz Test
Report 2: KH3962 M2 30M~300MHz Test
Report 3: KH3962 M3 30M~300MHz Test
-Page 3 -

EMI TEST REPORT


parameter

Organization: Philips
Operator:
Andrew
Place:
Netherland
Time:
2012/11/12/17:33
Detector:
PK+AV
Test-time(ms): 30
Limit:
EN55015
Transductor(PK/AV): PK / AV
Remark:
CFL11W from China 9k~30MHz

EUT:
CFL11W
Test equipment: KH3962
SN:
1262283

Start(MHz)
0.009
0.150
2.000
10.000

Step(MHz)
0.000
0.002
0.010
0.025

End(MHz)
0.150
2.000
10.000
30.000

freq, step

scan result

dBuV
120
110
100
90
80
70
60
50
40
30
20
10
0
0.01
0.009 MHz

0.05

0.10

0.50

1.00

5.00

10.00
30.000 MHz
final test

(QP)

freq(MHz)
0.073
0.218
0.361
1.018
4.213
11.548

lev(dBuV)
62.1
82.7
81.0
61.8
59.6
54.1

Lim(dBuV)
87.7
64.1
60.0
56.0
56.0
60.0

(lev-Lim)
-25.6
18.6
21.0
5.8
3.6
-5.9

(AV)

freq(MHz)
0.216
0.360
1.102
3.846

lev(dBuV)
73.8
70.8
54.6
52.6

Lim(dBuV)
54.1
50.0
46.0
46.0

(lev-Lim)
19.7
20.8
8.6
6.6

EMI TEST REPORT


parameter

Organization: Philips
Place:
Netherland
Detector:
PK
Limit:
EN55015CDN
Remark:
CFL11w from China M2 Test

Operator:
Andrew
Time:
2012/11/12/17:30
Test-time(ms): 30
Transductor(PK/AV): CDN / CDN

EUT:
CFL11W
Test equipment: KH3962
SN:
1262283

Start(MHz)
30.000
100.000
230.000

End(MHz)
100.000
230.000
300.000

Step(MHz)
0.100
0.150
0.200

freq, step

scan result

dBuV
80
70
60
50
40
30
20
10
0
50.00

100.00

30.000 MHz

300.000 MHz
final test

(QP)

freq(MHz)
91.370
107.650

lev(dBuV)
60.7
62.4

Lim(dBuV)
55.2
54.0

(lev-Lim)
5.5
8.4

EMI TEST REPORT


parameter

Organization: Philips
Place:
Netherland
Detector:
PK
Limit:
EN55015CDN
Remark:
CFL 11w from China M3 Test

Operator:
Andrew
Time:
2012/11/12/17:31
Test-time(ms): 30
Transductor(PK/AV): CDN / CDN

EUT:
CFL11W
Test equipment: KH3962
SN:
1262283

Start(MHz)
30.000
100.000
230.000

End(MHz)
100.000
230.000
300.000

Step(MHz)
0.100
0.150
0.200

freq, step

scan result

dBuV
80
70
60
50
40
30
20
10
0
50.00

100.00

30.000 MHz

300.000 MHz
final test

(QP)

freq(MHz)
91.350
103.660

lev(dBuV)
61.0
56.1

Lim(dBuV)
55.2
54.0

(lev-Lim)
5.8
2.1