What is PHPP?
Passive House Planning Package
- Energy balance calculation within a
conventional Excel format
- Simple and direct data input
- Validated accuracy of results
- Continuous further development
- Verification tool for Passive House
buildings and EnerPHit retrofits
- Includes detailed user manual with
energy efficiency advice
- Import/Export data interface for other
programmes
THERMAL
BRIDGES
INSULATION
WINDOWS
AIRTIGHTNESS
VENTILATION
(natural/mechanical)
SHADING
Verification
Start
Check
Variants
Comparison
PE- demand
worksheets
Cooling case
worksheets
Heating case
worksheets
DHW+Distribution
SummVent
Climate
U-Value
Building
envelope
SolarDHW
Mechanical
systems
Use non-res
Summer
Areas
Electr. non-res
Ground
Components
Passive
cooling?
Shading
yes
no
frequency
of overheating
10%
no
PV
IHG Non-Res
yes
Windows
Aux electricity
Cooling
Ventilation
Optional:
Compact
Cooling units
Additional vent
HP
Annual heating
HP Ground
Cooling load
Boiler
Heating
Input required
District heat
Heating load
no
Heating case
criteria met?
PE Value
yes
no
Cooling case
criteria met?*
yes
no
PE value
criteria met?
No entry required
yes
Passive
House /
EnerPHit
Monitoring projects:
Comparison of
calculated demand and
measured consumption
- Very good compliance of the energy demand calculated with PHPP and
the measured consumption or load detected in monitoring projects
- Compliance of the calculated heating load
- The more efficient the building, the lower the deviations
Primrenergie
/ Heizwrmebedarf
[kWh/(ma)]
Primary
energy / Heating
energy demand
[kWh/(ma)]
Bezug
auf
Nutzflche/
Wohnflche
Useful floor space / living space
Primrenergie
Primary
energy
WSchV
WSchV 77
77
150
150
Primary
Primrenergiebedarf:
energy demant: 180
180
Heating,
Heizung,hot
Warmwasser,
water,
160
160
auxiliary
Hilfsenergie
electricity
Heizwrme
Heat energy
140
140
Heat
Heizwrmebedarf
energy demand
WSchV 82
120
120
WSchV95
WSchV95
EnEV
EnEV
02/04/07
02/04/07
100
100
50
50
Source: 17
International
Passive House
Conference in
Frankfurt/M.
100
100
EnEV09
EnEV09
8080
EnEV14
EnEV14
6060
4040
Passivehouse
Pilot project
00
1978
1978 1982
1982 1986
1986 1990 1994 1998
1998 2002
2002 2006
2006 2010
2010 2014
2014 2018
2018
2020
00
2021
NZEB?
200 kWh/(ma)
Passive
House
Institute
Passive House Institute,
Jan
Steiger,
1 June
2015
15 kWh/(ma)
often
more
than
90%
Unterrainer
PH
Trend
Acc. EnEV
Efficiency technology
Avaiable
Sustainable
Energy
7 Very hot
6 Hot
5 Warm
4 Warm, temperate
3 Cool, temperate
2 Cold
1 Arctic
1 Energy recovery
Now including component and certification criteria for 7 international climate zones
Climate
Heating
climate
Cooling
climate
No
1
2
3
4
5
6
7
Region
Arctic
Cold
Cool-temperate
Warm-temperate
Warm
Hote
Very hot
Heating-/Cooling-Region Indicator
> 118
> 53,8
> 27
> -4
All others
> 118
> 139,5
Passivhaus Institut 2014
NEW! in PHPP 9
The energy balance and planning tool for efficient
buildings and retrofits such as Passive House
buildings and NZEBs
-
Renewable energy
gains
Energy demand
depending on use
Classic
Plus
Premium
classic
Efficiency !
120
Renewable
energy production
[kWhPER/(mGrund*a)]
30
plus
60
4530
classic
Renewable
Primary Energy Demand
[kWhPER/(mEBF*a)]
60
Renewable Primary Energy Demand: Heating, DHW, Auxhiliary and Appliances
Passive House Institute, Jan Steiger, 1 June 2015
Active variant
Variantenberechnung
Passivhaus-Reihenendhaus / Klima: PHPP-Standard / EBF: 156 m / Heizen: 19,86 kWh/(ma) / bertemperatur: 0,7 % / PER: 43,8 kWh/(ma)
5-EnerPHit
Bestand
Fenster und
Tren
Auenwanddmmung
Dach und
Luftdichtheitstest
EnerPHit
aktiv
Einheit
kWh/(ma)
19,9
13,2
174,2
71,9
107,1
47,3
48,5
25,0
27,8
16,7
19,9
13,2
0,7
43,8
nein
0,2
214,2
nein
0,0
0,2
140,5
nein
0,0
0,4
76,0
nein
0,0
0,6
52,2
nein
0,0
0,7
43,8
nein
0,0
Kessel
Fernwrme
aktive Variante
whlen >>
Ergebnisse
Heizwrmebedarf
Heizlast
Khl- + Entfeuchtungsbedarf
Khllast
bertemperaturhufigkeit (> 25 C)
PER-Bedarf
Passivhaus Classic?
W/m
kWh/(ma)
W/m
%
kWh/(ma)
ja / nein
Endenergie
Nutzerdefiniert: verknpfte Ergebnisse
Eingangsgren
Einheit
Bauteilschichten
U-Werte
Strahlungsbilanz
Flchen
Wrmebrcken
Flchen
Fenster
Lftung
Lftung
Wrmeerzeuger
Kompressor-Khlgerte
Nutzerdefiniert
25
Passive House Institute, Jan Steiger, 1 June 2015
PER
Khlgerte
Wert
500
400
Verschattung
300
SommLuft
200
WP
100
0
Kompakt
1-Bestand
www.europhit.eu
www.europhit.eu
www.europhit.eu
Cost-efficiency comparison
www.europhit.eu
Pilot Projects
www.europhit.eu/projects
www.europhit.eu
www.europhit.eu
Error messages
Plausibility checks
Plausibility checks
Which support
- Reasonable / corret data entry
- Avoiding typing errors
Passive House Institute, Jan Steiger, 1 June 2015
Component recommendations
The window traffic-
PHPP_V9.1_Tools
Centralisation of all PHPP tools in one file
Profile settings
Row insertion
Today
Component updates
Periodical update all Certified Passive House Components
Import of component update lists into PHPP9
Soon:
designPH 1.1:
-
designPH EDU:
-
designPH DEMO:
www.designph.org
Passive House Institute, Jan Steiger, 1 June 2015
www.passivehouse.com
Passive House Institute, Jan Steiger, 1 June 2015
THANK YOU
The Passive House Concept
High comfort
Highly efficient
Cost effective
Sustainable
Approved
User friendly
NZEB-ready
FOR YOUR
ATTENTION!
www.passivehouse.com
www.passipedia.org
www.designph.org
www.passivehouseconference.org