Sei sulla pagina 1di 8

Produced on 1/31/2011 with Xpress V5.4.4 - database Central 7.4.

7
Project name
Reference
Client name
Revision

SKY GATE
LEVEL 37,38-HIGH AMBIANT
-

Selection parameters of the indoor units can be found under the chapter Indoor unit details
Selection parameters of the outdoor units can be found under the chapter Outdoor unit details
Only the data published in the data book are correct. This program uses close approximations of these data.

1. Material List
Model

Qty

Description

RXYQ30PY1K

1 Heat pump VRV III RXYQP7Y1K

FXAQ25MV

1 A - Wall mounted unit

FXAQ40MV

1 A - Wall mounted unit

FXDQ50P7

2 D - Concealed ceiling unit (small)

FXDQ63P7

1 D - Concealed ceiling unit (small)

FXMQ100P7

2 M - Concealed ceiling unit (large)

FXMQ140P7

1 M - Concealed ceiling unit (large)

FXMQ250MA

1 M - Concealed ceiling unit (large)

FXMQ63P7

1 M - Concealed ceiling unit (large)

FXMQ80P7

1 M - Concealed ceiling unit (large)

KHRQ22M20T

2 REFNET branch piping kit

KHRQ22M29T9

2 REFNET branch piping kit

KHRQ22M64T

5 REFNET branch piping kit

KHRQ22M75T

1 REFNET branch piping kit

BRC1E51A

2 Remote controller

BHFQ22P1517

1 Outdoor unit multi connection piping kit for 3 outdoors

Piping 1/4"

5.0m

Piping 3/8"

42.0m

Piping 1/2"

16.0m

Piping 5/8"

31.0m

Piping 3/4"

9.0m

Piping 7/8"

15.0m

Piping 1 1/8"

16.0m

Piping 1 3/8"

8.0m

The Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Program.

Page 1

2. Indoor Unit Details


2.1. Table of Abbreviations
Name

Logical name of the device, possibly preceeded by room name

FCU

Device model name

Tmp C

Indoor conditions in cooling (dry bulb temp. / RH)

Rq TC

Required total cooling capacity

TC

Available total cooling capacity

Rq SC

Required sensible cooling capacity

SC

Available sensible cooling capacity

Tmp H

Indoor temperature in heating

Rq HC

Required heating capacity

HC

Available heating capacity (integrated heating capacity)

Airflow

Supplied airflow at low and high fan speed

Sound

Sound pressure low and high

PS

Power supply (voltage and phases)

MCA

Minimum Circuit Amps

Fuses

Fuses

WxHxD

WidthxHeightxDepth

Wght

Weight of the device

PI-C 50Hz Power input in cooling at 50Hz


PI-C 60Hz Power input in cooling at 60Hz
PI-H 50Hz Power input in heating at 50Hz
PI-H 60Hz Power input in heating at 60Hz

The Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Program.

Page 2

2.2. OU-TYP-07* - RXYQ30PY1K


Actual capacity data at conditions and combination ratio (128%) as entered
Name

FCU

Tmp C

Rq TC

TC

Rq SC

SC

Tmp H

Rq HC

HC

Airflow

kW

kW

kW

kW

kW

kW

l/s

BALCONY:AC-TYP-03

FXMQ63P7

23.3 / 55%

5.5*

5.5

5.5*

3.7

22.0

n/a

5.8 192-233

BEDROOM 4:AC-TYP-02

FXDQ50P7

23.0 / 55%

4.2*

4.5

3.2*

3.1

22.0

n/a

4.6 167-208

FAMILY ROOM:AC-TYP-05

FXMQ80P7

22.6 / 55%

7.0*

7.1

5.8*

4.9

22.0

n/a

7.4 267-325

BEDROOM 2:AC-TYO-02

FXDQ50P7

23.0 / 55%

4.2*

4.4

3.2*

3.1

22.0

n/a

4.6 167-208
9.2 383-483

MASTER BEDROOM 1:AC-TYP-06 FXMQ100P7

22.4 / 55%

8.3*

8.6

7.3*

6.3

22.0

n/a

BEDROOM 3:AC-TYP-03

FXDQ63P7

22.7 / 55%

5.4*

5.5

4.4*

3.8

22.0

n/a

5.8 217-275

KITCHEN+PANTRY:AC-TYP-08

FXMQ140P7

27.8 / 55%

12.8*

13.3

7.0*

8.7

22.0

n/a

12.9 533-650

STAFF ROOM 1:AC-TYP-11

FXAQ25MV

22.0 / 55%

1.8*

2.1

1.7*

1.7

22.0

n/a

2.3 83-133

STAFF ROOM 2:AC-TYP-12

FXAQ40MV

22.0 / 55%

3.1*

3.4

3.0*

2.7

22.0

n/a

3.7 150-200

DINING:AC-TYP-06

FXMQ100P7

23.4 / 55%

8.6*

9.0

5.9*

6.4

22.0

n/a

9.2 383-483

LIVING:AC-TYP-10

FXMQ250MA

23.2 / 55%

20.6*

22.4

15.1*

16.4

22.0

n/a

23.1 1033-1200

Total

86.0
Name

Sound

PS

MCA

dBA

Fuses

BALCONY:AC-TYP-03

38-42

230V 1ph

1.3 Factory Std

BEDROOM 4:AC-TYP-02

31-35

230V 1ph

1 Factory Std

FAMILY ROOM:AC-TYP-05

39-43

230V 1ph

1.5 Factory Std

BEDROOM 2:AC-TYO-02

31-35

230V 1ph

1 Factory Std

MASTER BEDROOM 1:AC-TYP-06 39-43

230V 1ph

BEDROOM 3:AC-TYP-03

32-36

KITCHEN+PANTRY:AC-TYP-08

61.0

88.8

WxHxD

Wght

PI-C 50Hz

PI-C 60Hz

PI-H 50Hz

mm

kg

kW

kW

kW

PI-H 6

kW

1000x300x700

35

0.120

0.120

0.108

900x200x620

28

0.165

0.185

0.152

1000x300x700

35

1.2

1.2

0.159

900x200x620

28

0.165

0.185

0.152

2.5 Factory Std

1400x300x700

46

0.176

0.176

0.164

230V 1ph

1.1 Factory Std

1100x200x620

31

0.181

0.192

0.168

43-45

230V 1ph

3.4 Factory Std

1400x300x700

47

0.461

0.460

0.449

STAFF ROOM 1:AC-TYP-11

29-36

230V 1ph

0.4 Factory Std

795x290x230

11

0.022

0.022

0.027

STAFF ROOM 2:AC-TYP-12

34-39

230V 1ph

0.4 Factory Std

1050x290x230

14

0.020

0.020

0.020

DINING:AC-TYP-06

39-43

230V 1ph

2.5 Factory Std

1400x300x700

46

0.176

0.176

0.164

LIVING:AC-TYP-10

45-48

230V 1ph

9 Factory Std

1380x470x1100

137

Diversified capacity data at conditions as entered and 100% combination ratio


Name

TC

SC

HC

kW

kW

kW

BALCONY:AC-TYP-03

5.9

3.9

6.5

BEDROOM 4:AC-TYP-02

4.7

3.2

5.2

FAMILY ROOM:AC-TYP-05

7.3

5.0

8.4

BEDROOM 2:AC-TYO-02

4.7

3.2

5.2

MASTER BEDROOM 1:AC-TYP-06

8.9

6.4

10.5

BEDROOM 3:AC-TYP-03

5.7

3.9

6.5

16.1

9.8

14.6

STAFF ROOM 1:AC-TYP-11

2.2

1.7

2.6

STAFF ROOM 2:AC-TYP-12

3.5

2.7

4.2

DINING:AC-TYP-06

9.7

6.7

10.5

LIVING:AC-TYP-10

23.8

17.0

26.1

KITCHEN+PANTRY:AC-TYP-08

Outdoor unit placed 3.0m below the indoor units.


The minimum connection ratio for this height difference is 50%.

The Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Program.

Page 3

3. Outdoor Unit Details


3.1. Table of Abbreviations
Name

Logical name of the device

Model

Device model name

Comb

Combination percentage

Tmp C

Outdoor temperature in cooling

CC

Cooling capacity

EER

EER at selection and nominal conditions

Tmp H

Outdoor temperature in heating

HC

Heating capacity (integrated heating capacity)

COP

COP at selection and nominal conditions

Piping

Largest distance from indoor unit to outdoor unit

Bse Refr

Standard factory refrigerant charge (5m actual piping length)


excluding extra refrigerant charge
For calculation of extra refrigerant charge refer to the databook

Ex Refr

Extra refrigerant charge

PS

Power supply (voltage and phases)

MCA

Minimum Circuit Amps

Run Amps

Running Amps

St Curr

Starting current

Fuses

Fuses

WxHxD

WidthxHeightxDepth

Wght

Weight of the device

The Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Program.

Page 4

3.2. Outdoor Details


Name
OU-TYP-07*
Name
OU-TYP-07*

Model
RXYQ30PY1K
Model
RXYQ30PY1K

Comb

Tmp C

CC

kW

128
PS

34.0

89.3

Tmp H

HC

kW

4.2 / 3.9

5.0

MCA

Run Amps

St Curr

COP

88.8

Piping

Bse Refr

Ex Refr

kg

kg

3.6 / 4.3

Fuses

400V 3Nph

34.0

27.4

23.1

12.9

75

cfr. local legislation

* RXYQ10PY1K

23.1

10

74

cfr. local legislation

19

8.2

8.9

WxHxD

Wght

mm

kg

3720x1680x765

* RXYQ12PY1K
* RXYQ8PY1K

EER

840

cfr. local legislation

The Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Program.

Page 5

4. Piping Diagrams
Pipes marked with * in the diagrams must be connected to the device with a reducing joint.

4.1. Piping OU-TYP-07*


OU-TYP-07*
RXYQ30PY1K
RXYQ12PY1K

RXYQ10PY1K

1/2"x1 1/8"
5/8"x1 1/8"
BHFQ22P1517
8.0m [3]
3/4"x1 3/8"

RXYQ8PY1K

3/8"x7/8"

3/8"x3/4"

8.0m [1]
1/2"x1 1/8"
KHRQ22M75T

11.0m [2]
3/8"x5/8"
KHRQ22M64T
AC-TYP-03
FXMQ63P7

1.0m
1/2"x1 1/8"

1.0m
1/4"x1/2"
KHRQ22M64T
AC-TYP-02
FXDQ50P7

1.0m
1/2"x1 1/8"

2.0m [1]
3/8"x5/8"
KHRQ22M64T
AC-TYP-05
FXMQ80P7

2.0m
3/8"x7/8"

1.0m
1/4"x1/2"
KHRQ22M29T9
AC-TYO-02
FXDQ50P7

1.0m
3/8"x3/4"

7.0m [2]
3/8"x5/8"
KHRQ22M20T
AC-TYP-06
FXMQ100P7
2.0m [1]
3/8"x5/8"

AC-TYP-03
FXDQ63P7
5.0m
5/8"x1 1/8"

9.0m [1]
3/8"x7/8"
KHRQ22M64T

1.0m
3/8"x5/8"
KHRQ22M29T9
AC-TYP-08
FXMQ140P7

1.0m
3/8"x5/8"

2.0m [1]
1/4"x1/2"
KHRQ22M20T
AC-TYP-11
FXAQ25MV
1.0m [1]
1/4"x1/2"

AC-TYP-12
FXAQ40MV
1.0m
1/2"x1 1/8"

2.0m [1]
3/8"x5/8"
KHRQ22M64T
AC-TYP-06
FXMQ100P7
4.0m [1]
3/8"x7/8"

AC-TYP-10
FXMQ250MA

The Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Program.

Page 6

5. Wiring Diagrams
P1P2 = 16-2 AWG 2 core non screened stranded wire (non polarity wiring system)
F1F2 = 16-2 AWG 2 core non screened stranded wire (non polarity wiring system)

5.1. Wiring OU-TYP-07*


OU-TYP-07*
RXYQ30PY1K

24A 1ph

AC-TYP-03
FXMQ63P7
IN F1,F2

F1,F2

L,N

1.3A 1ph

L,N

1A 1ph

L,N

1.5A 1ph

L,N

1A 1ph

L,N

2.5A 1ph

L,N

1.1A 1ph

RXYQ12PY1K
Q1,Q2

AC-TYP-02
FXDQ50P7

L1,L2,L3,N
23A 3Nph
RXYQ10PY1K

Q1,Q2

F1,F2

L1,L2,L3,N

AC-TYP-05
FXMQ80P7

23A 3Nph
F1,F2

RXYQ8PY1K
Q1,Q2

L1,L2,L3,N

AC-TYO-02
FXDQ50P7

19A 3Nph
F1,F2

AC-TYP-06
FXMQ100P7
F1,F2
AC-TYP-03
FXDQ63P7
F1,F2
AC-TYP-08
FXMQ140P7
F1,F2

P1,P2

BRC1E51A

L,N

3.4A 1ph

L,N

0.4A 1ph

L,N

0.4A 1ph

L,N

2.5A 1ph

AC-TYP-11
FXAQ25MV
F1,F2
AC-TYP-12
FXAQ40MV
F1,F2
AC-TYP-06
FXMQ100P7
F1,F2
AC-TYP-10
FXMQ250MA
F1,F2

P1,P2
L,N

BRC1E51A
9A 1ph

The Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Program.

Page 7

6. Device Options
6.1. Outdoor Unit Options
Model

Description

BHFQ22P1517 Outdoor unit multi connection piping kit for 3 outdoors

Used by
OU-TYP-07* [RXYQ30PY1K]

The Xpress Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Program.

Page 8

Potrebbero piacerti anche